2106 v3
TRANSCRIPT
RBS 2106(V3) Product Presentation
Surash PerumalEngineer, RAN
Top right corner for field-mark, customer or partner logotypes. See Best practice for example.
Slide title 40 pt
Slide subtitle 24 pt
Text 24 pt
Bullets level 2-520 pt
Commercial in confidence ECM/FRC SURASH PERUMAL 2007-11-212
Agenda
• Introduction
• Main Units
• Selection Units
• RBS 2106(V3) Antenna Configuration
• Multi Cabinet Configuration
• LTB of RBS 2X02 with DXU21
• OMT – SW for RBS2106 V3
• RBS2106(V3) - DC load for battery back-up
• RBS2106(V3) – Data Sheet
Introduction
• 12 TRX capacity
• Standard Ericsson footprint
• Hybrid and filter combining
• Configurable for each situation
• Few replaceable units
RBS 2106 (V3)
4
Top right corner for field-mark, customer or partner logotypes. See Best practice for example.
Slide title 40 pt
Slide subtitle 24 pt
Text 24 pt
Bullets level 2-520 pt
Commercial in confidence ECM/FRC SURASH PERUMAL 2007-11-214
Main Units dTRU, A two TRX replaceable unit
- Two TRXs in one Replaceable Unit (dTRU)- 450, 800, 900, 1800 or 1900 MHz- Built in by-passable hybrid- Remote loadable software- Automatic selection of ciphering algorithm- Extended Range- Four Branch Receiver Diversity (4WRD)- Transceiver Coherent Combining (TCC)- AMR
DXU 23, System unit for interface towards the BSC (Not backward Compatible)- Transmission interface- 4x E1/T1 connections (2x RJ45 ports)- TG synchronization- GPS interface- Positioning- Network synchronization- LAPD Multiplexing/Concentration- Multi Drop
CXU, Software controlled RX Configuration Switch
- Distributes the RX signals from the CDUs to the dTRUs- Software re-configuration- One single version for 450/800/900/1800/1900- Minimises the number of RX-cables
Top right corner for field-mark, customer or partner logotypes. See Best practice for example.
Slide title 40 pt
Slide subtitle 24 pt
Text 24 pt
Bullets level 2-520 pt
Commercial in confidence ECM/FRC SURASH PERUMAL 2007-11-215
Selections Units Single or Dual band
CDU, Combining and Distribution Unit
CDU-F, Auto tuned Filter Combiner for High Capacity Sites- Filter combiner- 900, 1800, 1900 MHz- 400 kHz channel spacing- Common TX/RX antenna always supported- 12 combined carriers on two TX/RX antennas- Mixing of different frequencies in one cabinet (dual band)Same size as CDU-G
CDU-G, Hybrid Combiner for Capacity and Coverage- A filter unit with hybrid located in dTRU- 450, 800, 900, 1800 or 1900 MHz- Common TX/RX antenna always supported- 4 combined or 2 uncombined carriers on two TX antennas
CDU-K, Hybrid Combiner for advanced configurations- A filter unit with hybrid located in dTRU- 450, 800, 900, 1800 or 1900 MHz- Common TX/RX antenna always supported- 4 combined or 2 uncombined carriers on two TX antennas- Mixing of different frequencies in one cabinet (dual band)- 4-WRD in a easy way- ½ size compared to CDU-G but with same specification
Top right corner for field-mark, customer or partner logotypes. See Best practice for example.
Slide title 40 pt
Slide subtitle 24 pt
Text 24 pt
Bullets level 2-520 pt
Commercial in confidence ECM/FRC SURASH PERUMAL 2007-11-216
Selections Units TMA
- DTMA or STMA- TMA-CM- TMA BIAS
HCU, Hybrid Combiner Unit ASU, Antenna Sharing Unit
Power and Back up system (Not Backward Compatible)• 3 Power options - 120 - 250 V AC (picture) ACCU
PSU AC/DC Support for battery backup - -48/-60 V DC
DCCUPSU DC/DC
- +24 V DC, DC filter and no PSUs• Sharing of common battery source with RBS 2216, 2202, 200• Typical power consumption fully equipped cabinet - 1.3 kW (+24 VDC) - 1.5 kW (230 VAC or –48/60 VDC)
Top right corner for field-mark, customer or partner logotypes. See Best practice for example.
Slide title 40 pt
Slide subtitle 24 pt
Text 24 pt
Bullets level 2-520 pt
Commercial in confidence ECM/FRC SURASH PERUMAL 2007-11-217
RBS 2106(V3) Antenna Configuration
CDU-G Configuration
Top right corner for field-mark, customer or partner logotypes. See Best practice for example.
Slide title 40 pt
Slide subtitle 24 pt
Text 24 pt
Bullets level 2-520 pt
Commercial in confidence ECM/FRC SURASH PERUMAL 2007-11-218
RBS 2106(V3) Antenna Configuration
CDU-G Configuration
Top right corner for field-mark, customer or partner logotypes. See Best practice for example.
Slide title 40 pt
Slide subtitle 24 pt
Text 24 pt
Bullets level 2-520 pt
Commercial in confidence ECM/FRC SURASH PERUMAL 2007-11-219
RBS 2106(V3) Antenna Configuration
CDU-K Configuration
Top right corner for field-mark, customer or partner logotypes. See Best practice for example.
Slide title 40 pt
Slide subtitle 24 pt
Text 24 pt
Bullets level 2-520 pt
Commercial in confidence ECM/FRC SURASH PERUMAL 2007-11-2110
RBS 2106(V3) Antenna Configuration
CDU-K Configuration
Top right corner for field-mark, customer or partner logotypes. See Best practice for example.
Slide title 40 pt
Slide subtitle 24 pt
Text 24 pt
Bullets level 2-520 pt
Commercial in confidence ECM/FRC SURASH PERUMAL 2007-11-2111
RBS 2106(V3) Antenna Configuration
CDU-F Configuration
Top right corner for field-mark, customer or partner logotypes. See Best practice for example.
Slide title 40 pt
Slide subtitle 24 pt
Text 24 pt
Bullets level 2-520 pt
Commercial in confidence ECM/FRC SURASH PERUMAL 2007-11-2112
RBS 2106(V3) Antenna Configuration
CDU-F Configuration
Top right corner for field-mark, customer or partner logotypes. See Best practice for example.
Slide title 40 pt
Slide subtitle 24 pt
Text 24 pt
Bullets level 2-520 pt
Commercial in confidence ECM/FRC SURASH PERUMAL 2007-11-2113
Multi-cabinet Configurations
Multi-cabinet configurations can be built as per stated below ;
- RBS 2106i + RBS 2106(V3)
- RBS 2102 + RBS 2106(V3)
Top right corner for field-mark, customer or partner logotypes. See Best practice for example.
Slide title 40 pt
Slide subtitle 24 pt
Text 24 pt
Bullets level 2-520 pt
Commercial in confidence ECM/FRC SURASH PERUMAL 2007-11-2114
Interfaces for DXU-21 and DXU-23
RBS 2106i RBS 2106V3
Multi-cabinet Configurations
Top right corner for field-mark, customer or partner logotypes. See Best practice for example.
Slide title 40 pt
Slide subtitle 24 pt
Text 24 pt
Bullets level 2-520 pt
Commercial in confidence ECM/FRC SURASH PERUMAL 2007-11-2115
Interface Interface - Type Cable Type
PCM A/C - in (Master) E1 75 Ohm cable
PCM B/D – Out (Master)
PCM A/C - In (Slave)
E1 75 Ohm cable
TG – Synch interface between RBS2106i & RBS2106(V3)
Twisted pair
External Alarm interface Twisted pair
Legend
Multi-cabinet Configurations Interfaces for DXU-21 and DXU-23
Top right corner for field-mark, customer or partner logotypes. See Best practice for example.
Slide title 40 pt
Slide subtitle 24 pt
Text 24 pt
Bullets level 2-520 pt
Commercial in confidence ECM/FRC SURASH PERUMAL 2007-11-2116
Interfaces for DXU-23 and DXU-23
RBS 2106V3 RBS 2106V3
Multi-cabinet Configurations
Top right corner for field-mark, customer or partner logotypes. See Best practice for example.
Slide title 40 pt
Slide subtitle 24 pt
Text 24 pt
Bullets level 2-520 pt
Commercial in confidence ECM/FRC SURASH PERUMAL 2007-11-2117
Interface Interface - Type Cable Type
PCM A/C - in (Master) E1 75 Ohm cable
PCM B/D – Out (Master)
PCM A/C - In (Slave)
E1 75 Ohm cable
TG – Synch interface between RBS2106(V3) & RBS2106(V3)
Twisted pair
External Alarm interface Twisted pair
Legend Interfaces for DXU-23 and DXU-23
Multi-cabinet Configurations
Top right corner for field-mark, customer or partner logotypes. See Best practice for example.
Slide title 40 pt
Slide subtitle 24 pt
Text 24 pt
Bullets level 2-520 pt
Commercial in confidence ECM/FRC SURASH PERUMAL 2007-11-2118
Interfaces for DXU-11 and DXU-23
Bus terminator RPT 403 804/01
External Alarm Connected to EACURBS 2102 RBS 2106V3
Synchronization BusG703-1
G703-2
Multi-cabinet Configurations
Top right corner for field-mark, customer or partner logotypes. See Best practice for example.
Slide title 40 pt
Slide subtitle 24 pt
Text 24 pt
Bullets level 2-520 pt
Commercial in confidence ECM/FRC SURASH PERUMAL 2007-11-2119
Legend
Interface Interface - Type Cable Type
PCM interface from TM box to Connection Field
PCM Cable
(RPM 513 1509/0 1000 (75Ω))
PCM interface from DXU11 to Connection Field
RPM 513 868/01300 (75 Ω)
Cascading RBS 2106i with RBS 2106(V3) PCM Cable
(RPM 513 1509/0 1000 (75Ω))
Synchronization Interface from DXU11 to Connection Field
Signal ESB (internal)
(RPM 513 1102/01620)
TG – Synch interface between RBS2102 & RBS2106(V3)
Twisted pair
Interfaces for DXU-11 and DXU-23
Multi-cabinet Configurations
Top right corner for field-mark, customer or partner logotypes. See Best practice for example.
Slide title 40 pt
Slide subtitle 24 pt
Text 24 pt
Bullets level 2-520 pt
Commercial in confidence ECM/FRC SURASH PERUMAL 2007-11-2120
Interfaces for DXU-21 and DXU-23
Bus terminator RPT 403 804/01
External Alarm Connected to EACURBS 2102 RBS 2106V3
Port A
Port C
Port B
Port D
ESB Port
Multi-cabinet Configurations
Top right corner for field-mark, customer or partner logotypes. See Best practice for example.
Slide title 40 pt
Slide subtitle 24 pt
Text 24 pt
Bullets level 2-520 pt
Commercial in confidence ECM/FRC SURASH PERUMAL 2007-11-2121
Legend
Interface Interface - Type Cable Type
PCM interface from TM box to Connection Field
PCM Cable
(RPM 513 1509/0 1000 (75Ω))
PCM interface from DXU21 to Connection Field
RPM 513 868/01300 (75 Ω)
Cascading RBS 2106i with RBS 2106(V3)
PCM Cable
(RPM 513 1509/0 1000 (75Ω))
Synchronization Interface from DXU21 to Connection Field
Signal ESB (internal)
(RPM 513 1102/01620)
TG – Synch interface between RBS2102 & RBS2106(V3)
Twisted pair
Interfaces for DXU-21 and DXU-23Multi-cabinet Configurations
Top right corner for field-mark, customer or partner logotypes. See Best practice for example.
Slide title 40 pt
Slide subtitle 24 pt
Text 24 pt
Bullets level 2-520 pt
Commercial in confidence ECM/FRC SURASH PERUMAL 2007-11-2122
LTB of RBS 2X02 with DXU21
For RBS 2X02 with DXU 21
- End of Sales is June of 2008
- End of Support is December 2016
Top right corner for field-mark, customer or partner logotypes. See Best practice for example.
Slide title 40 pt
Slide subtitle 24 pt
Text 24 pt
Bullets level 2-520 pt
Commercial in confidence ECM/FRC SURASH PERUMAL 2007-11-2123
OMT – SW for RBS2106 V3
• OMT version that is able to support 2106V3 is
- RBS 2000 OMT SW LZY 213 1034/1 R33/6 or later
Top right corner for field-mark, customer or partner logotypes. See Best practice for example.
Slide title 40 pt
Slide subtitle 24 pt
Text 24 pt
Bullets level 2-520 pt
Commercial in confidence ECM/FRC SURASH PERUMAL 2007-11-2124
RBS2106(V3) - DC load for battery back-up
Adobe Acrobat Document
• Please refer to attached PDF file on D
Top right corner for field-mark, customer or partner logotypes. See Best practice for example.
Slide title 40 pt
Slide subtitle 24 pt
Text 24 pt
Bullets level 2-520 pt
Commercial in confidence ECM/FRC SURASH PERUMAL 2007-11-2125
RBS2106(V3) – Data Sheet
Top right corner for field-mark, customer or partner logotypes. See Best practice for example.
Slide title 40 pt
Slide subtitle 24 pt
Text 24 pt
Bullets level 2-520 pt
Commercial in confidence ECM/FRC SURASH PERUMAL 2007-11-2126