2016 led board - elektrogros.ch · accertare potenziali danni al modulo led. elettricità statica...

2
TCI professional LED applications 48 www.tci.it professional led applications 3. Round LED modules Moduli LED rotondi RM90R24 - RM110R40 - RM130R65 RM90R24 RM110R40 RM130R65 Article Articolo Code Codice CCT K Current mA Flux Tc 25°C lm Flux Tc 65°C lm Power Tc 65°C W Efficacy Tc 25°C lm/W Efficacy Tc 65°C lm/W Ipk mA Vmax. Tc 25°C @Imax RM90R24 128172/830S 3000 250 960 900 5,8 166 156 500 25,0 350 1300 1210 8,4 156 145 500 1770 1650 12,4 143 133 128172/840S 4000 250 1010 940 5,8 175 163 350 1370 1280 8,4 164 153 500 1860 1730 12,4 150 140 128172/850S 5000 250 1030 960 5,8 178 166 350 1400 1310 8,4 168 157 500 1910 1780 12,4 155 144 RM110R40 128159/830S 3000 350 1350 1260 8,0 168 157 750 25,0 500 1880 1750 11,9 158 147 700 2530 2360 17,2 147 137 128159/840S 4000 350 1420 1330 8,0 177 166 500 1980 1850 11,9 167 156 700 2660 2480 17,2 155 144 128159/850S 5000 350 1460 1360 8,0 182 169 500 2030 1890 11,9 171 159 700 2740 2550 17,2 159 148 RM130R65 128173/830S 3000 350 2190 2040 13,1 168 156 750 40,6 500 3050 2840 19,3 158 147 700 4110 3830 27,9 147 137 128173/840S 4000 350 2300 2140 13,1 176 164 500 3200 2980 19,3 166 154 700 4310 4010 27,9 154 144 128173/850S 5000 350 2370 2210 13,1 181 169 500 3290 3060 19,3 171 159 700 4440 4130 27,9 159 148 • Morsetti ad innesto rapido. • Fissaggio del modulo tramite viti. • Idoneo per applicazioni NON SELV (distanza parte in tensione dal bordo scheda ≥3mm). • CCT speciali disponibili su richiesta per lotti minimi da definire (2700 K, 5700 K, 6500 K). • CRI speciali disponibili su richiesta per lotti minimi da definire (>90). • Possibilità di alimentazione in emergenza tramite inverter TCI. • I moduli LED TCI non sono protetti contro extra tensioni, sovraccarichi e cortocircuiti. • L’utilizzo è garantito in combinazione con driver TCI. Per ulteriori dettagli tecnici consultare www.tci.it. • Push-in terminal blocks. • Modules can be secured by means of slot for screws. • Suitable for NOT SELV applications (distance between the voltage part of the board and the border ≥3mm). • Special CCT available upon request for minimum order quantity (2700 K, 5700 K, 6500 K). • Special CRI available upon request for minimum order quantity (>90). • Suitable for emergency applications with TCI inverters. • TCI LED modules are not equipped against voltage spikes, overloads and short circuits. • The use is guaranteed in combination with TCI drivers. For additional technical informations see www.tci.it. The mentioned data can have a 10% tolerance - Il dato indicato può avere una tolleranza del 10%. Color rendering index Indice resa cromatica CRI: >80 Color tolerance Tolleranza colore 3 MacAdam (3 SDCM) Beam angle emission Angolo emissione 120 ° Ambient temperature Temperatura ambiente Ta: -25...+55 °C (Only for Tc ≤85°C) Module temperature Temperatura modulo Tc max: 85 °C Life time >50.000 h - L80B10 (@ Tc=55 °C / Ipk) Life time >50.000 h - L70B50 (@ Tc=85 °C / Ipk) Reference Norms Norme di riferimento: CSA-C22.2 no.250.13-14 EN 50581 EN 55015 EN 61547 EN 62031 EN 62471 IEC 62778 UL 8750 7-9 mm Wiring preparation 0,2 - 0,75 mm 2 Insert/removing wires by lightly pressing on push-button. Inserire/rimuovere i cavi premendo leggermente sul pulsante. ESD 182 L80 B10 Made in Europe >50.000 h 15

Upload: others

Post on 28-May-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

TCI professional LED applications48 www.tci.it

professional led applications

3.

Roun

d LE

D m

odul

esM

odul

i LED

roto

ndi

RM90R24 - RM110R40 - RM130R65

RM90R24 RM110R40 RM130R65

Article Articolo

Code Codice

CCT K

Current mA

Flux Tc 25°C

lm

Flux Tc 65°C

lm

Power Tc 65°C

W

Efficacy Tc 25°C

lm/W

Efficacy Tc 65°C

lm/W

Ipk mA

Vmax. Tc 25°C@Imax

RM90R24 128172/830S 3000 250 960 900 5,8 166 156 500 25,0

350 1300 1210 8,4 156 145500 1770 1650 12,4 143 133

128172/840S 4000 250 1010 940 5,8 175 163350 1370 1280 8,4 164 153500 1860 1730 12,4 150 140

128172/850S 5000 250 1030 960 5,8 178 166350 1400 1310 8,4 168 157500 1910 1780 12,4 155 144

RM110R40 128159/830S 3000 350 1350 1260 8,0 168 157 750 25,0

500 1880 1750 11,9 158 147700 2530 2360 17,2 147 137

128159/840S 4000 350 1420 1330 8,0 177 166500 1980 1850 11,9 167 156700 2660 2480 17,2 155 144

128159/850S 5000 350 1460 1360 8,0 182 169500 2030 1890 11,9 171 159700 2740 2550 17,2 159 148

RM130R65 128173/830S 3000 350 2190 2040 13,1 168 156 750 40,6

500 3050 2840 19,3 158 147700 4110 3830 27,9 147 137

128173/840S 4000 350 2300 2140 13,1 176 164500 3200 2980 19,3 166 154700 4310 4010 27,9 154 144

128173/850S 5000 350 2370 2210 13,1 181 169500 3290 3060 19,3 171 159700 4440 4130 27,9 159 148

• Morsetti ad innesto rapido. • Fissaggio del modulo tramite viti. • Idoneo per applicazioni NON SELV (distanza parte in tensione dal bordo scheda ≥3mm). • CCT speciali disponibili su richiesta per lotti minimi da definire (2700 K, 5700 K, 6500 K). • CRI speciali disponibili su richiesta per lotti minimi da definire (>90). • Possibilità di alimentazione in emergenza tramite inverter TCI.• I moduli LED TCI non sono protetti contro extra tensioni, sovraccarichi e cortocircuiti. • L’utilizzo è garantito in combinazione con driver TCI.Per ulteriori dettagli tecnici consultare www.tci.it.

• Push-in terminal blocks. • Modules can be secured by means of slot for screws. • Suitable for NOT SELV applications (distance between the voltage part of the board and the border ≥3mm). • Special CCT available upon request for minimum order quantity (2700 K, 5700 K, 6500 K). • Special CRI available upon request for minimum order quantity (>90). • Suitable for emergency applications with TCI inverters.• TCI LED modules are not equipped against voltage spikes, overloads and short circuits. • The use is guaranteed in combination with TCI drivers. For additional technical informations see www.tci.it.

The mentioned data can have a 10% tolerance - Il dato indicato può avere una tolleranza del 10%.

Color rendering index Indice resa cromatica CRI: >80

Color tolerance Tolleranza colore 3 MacAdam (3 SDCM)

Beam angle emission Angolo emissione 120 °

Ambient temperature Temperatura ambienteTa: -25...+55 °C (Only for Tc ≤85°C)

Module temperature Temperatura moduloTc max: 85 °C

Life time>50.000 h - L80B10 (@ Tc=55 °C / Ipk)

Life time>50.000 h - L70B50 (@ Tc=85 °C / Ipk)

Reference Norms Norme di riferimento:CSA-C22.2 no.250.13-14 EN 50581 EN 55015 EN 61547 EN 62031EN 62471 IEC 62778UL 8750

7-9 mm

Wiring preparation 0,2 - 0,75 mm2

Insert/removing wires by lightly pressing on push-button. Inserire/rimuovere i cavi premendo leggermente sul pulsante.

ESD

182

L80B10

Made in Europe

>50.000 h

15

TCI professional LED applications 49www.tci.it

professional led applications

3.

Roun

d LE

D m

odul

esM

odul

i LED

roto

ndi

RM90R24 - RM110R40 - RM130R65Dimensions/Dimensioni - Weight/Peso - Pcs/Pezzi

RM90R24 (Weight/Peso 0,74 oz. / gr. 21 - Pcs/Pezzi 180)

RM110R40 (Weight/Peso 1,12 oz. / gr. 32 - Pcs/Pezzi 80)

RM130R65 (Weight/Peso 1,55 oz. / gr. 44 - Pcs/Pezzi 80)

Ø 90 mm± 0,15

6

6Ø 110 mm± 0,15

Ø 2,60 mm

6Ø 130 mm± 0,15

Ø 2,60 mm

Dissipazione e assemblaggio Può essere necessaria una dissipazione del modulo LED per garantire i dati di luminosità e durata preceden-temente indicati, verificare che la Tc del modulo non superi i valori massimi indicati nella tabella. Si consiglia l’utilizzo di tutte le viti presenti sul modulo LED per il fissaggio o l’utilizzo di pasta o adesivi termoconduttivi. Per non danneggiare i moduli LED utilizzare soltanto viti a testa arrotondata e rondelle plastiche piatte. Se i moduli LED sono collegati in parallelo e un modulo si danneggia, tutta la corrente che passa nell’altro modulo LED aumenta. Questo potrebbe ridurre il lifetime del modulo LED.Uso e pulizia Non procurare shock ai moduli LED e conservarli in luogo non polveroso. Evitare il contatto con qualsiasi tipo di fluido, come olio o solventi organici. Si raccomanda l’uso di IPA (alcool isopropilico) quale solvente per la pulizia dei moduli LED. Prima di procedere con la pulizia, dovrebbe essere effettuato un pre-test per accertare potenziali danni al modulo LED.Elettricità staticaL’elettricità statica o le tensioni di rete possono danneggiare i moduli LED. Indossare un braccialetto ESD o guanti ESD durante l’uso dei moduli LED. LifetimeIl valore di luminosità di un modulo LED in base a 50.000h di funzionamento è indicato dalla lettera L. La lettera B indica invece il numero dei LED che rispetteranno il valore L dopo 50.000 ore di funzionamento. I moduli LED TCI sono garantiti L80B10, che significa che il 90% dei LED avranno una resa uguale o superiore all ’80% dopo 50.000h di utilizzo.

Dissipation, assembly A dissipation of the LED module might be required to guarantee the stated datas of brightness and lifetime. Please verify that the module’s Tc does not exceed the maximum values as indicated in the table. It is recommended the use of all the screws on the LED module for the fixation or the use of thermoconductive pastes or adhesives. To not damage the LED module only rounded head screw and an additional plastic flat washer should be used. If LED modules are wired in parallel and a module fails, the current flowing totally trought the other LED module increases. This may reduce the lifetime of the LED module.Handling and Cleaning Don’t give to the LED modules any shock and store the LED modules in a dusty place or room. Avoid contact with any type of fluid such as oil or organic solvents, its recommended IPA (isopropyl Alcohol) be used as solvent for cleaning the LED module. Before cleaning, a pre test should be done to confirm whether any damage to the LED lighting will occur.Static Electricity Static electricity or surge voltage can damage the LED modules. Wear anti ESD wrist band or anti ESD gloves when handling the LED modules.Lifetime The brightness value of a LED module according to 50.000 working hours is indicated by letter L. Letter B indicates the number of LEDs that keep the L value also after 50,000 working hours. TCI LED modules are guaranteed L80B10. In other words the 90% of the LEDs will have the same rendering or above 80% after 50.000 working hours.

Rela

tive

lum

inou

s flu

x (%

)

Tc (°C)

105

100

95

90

85

8020 30 40 50 60 70 80 90 100 110

Relative luminous flux vs. temperature - Flusso luminoso relativo vs temperatura

Luminous flux - Flusso luminoso

% I max.

% Flux max.

100%

100%

90%

80%

70%

60%

50%

40%

30%

20%

10%

0%0% 10% 20% 30% 40% 50% 60% 70% 80% 90%

Color space (tc 85°C) - Spazio di colore (tc 85°C)0,45

0,32

0,44

0,43

0,42

0,41

0,40

0,39

0,38

0,37

0,36

0,35

0,34

0,33

0,32

0,33

0,34

0,35

0,36

0,37

0,38

0,39

0,40

0,41

0,42

0,43

0,44

0,45

0,46

0,47

0,48

0,49

5700K

5000K

4500K 4000K

3000K

ANSI C78.377 Quadrangle EasyWhite 3-step