2014-aexio-xeuspro-technical.pdf
TRANSCRIPT
www.infovista.com
Copyright © 2013 InfoVista S.A. All rights reserved.
AEXIO SOLUTIONS Intelligent Optimization
Copyright © 2013 InfoVista S.A. All rights reserved.
www.infovista.com
XEUS DESKTOP OPTIMIZATION Network Troubleshooting and Analysis
3Copyright © 2013 InfoVista S.A. All rights reserved.
Traffic Measurement Recording Modules
• Neighbor Optimization
• Pilot Pollution Analysis
• Coverage Analysis
• VIP Analysis• Subscriber KPI
Analysis• Phone Profiling• Smart Phone
Analysis*
• Cell Analysis• Blocked/Dropped
Analysis• Throughput
Analysis
QOS Analysis
Network Optimization
User Quality Management
• Coverage Plot• User Positioning
Live Geo-Analysis
Call Search Task Manager
Ericsson GPEH (till W13B)
Huawei PCHR (till RAN15)
NSN Megamon & ICSU (30.9-0)
Data Sources
Excel Reporting
* - GPEH Only
ZTE CTS (Version 4.11)
Ericsson LTE UE/Cell Trace (till L12B)
ZTE LTE CTS (Version 4.11)
Huawei LTE SIG *
* - BETA version. Full version in Q1 2014.
4Copyright © 2013 InfoVista S.A. All rights reserved.
INSTALLATION GUIDE
System Requirements for Xeus TMR:
Components Requirements
Computer and Processor Pentium i5 or higher.
Memory 2 Gigabyte (GB) and above. *Recommended 8GB of RAM for best performance.
Hard Disk Minimum space required is 100 GB
Third-party MapInfo Professional 8 and above and Google Earth (optional)
Operating System Windows XP, Vista or 7 (32 or 64 bit), Windows 8.1
5Copyright © 2013 InfoVista S.A. All rights reserved.
XEUS PRO PROGRAM MENU
Quick Guide for TMR
Task Manager for manual queue parsing and auto-scheduling (TAM – Task Automation Module)
6Copyright © 2013 InfoVista S.A. All rights reserved.
GETTING STARTED FOR TMR
1. Update Network Data prior of importing TMR files. This is important for correct Cell Name Matching
2. Collect TMR files
3. Plan import strategy. Recommended 3 hours data for one RNC for each import
7Copyright © 2013 InfoVista S.A. All rights reserved.
ERICSSON GPEH/UETR/CTR COLLECTION
Configure GPEH Settings
gpehDataLevel = ALL_DATA
gpehFileSize = 50000
Collect GPEH Event based on analysis Scenario. Refer TMR Quick Guide Appendix 1c for list of event
Important: Include RRC Measurement & NBAP Radio Link Setup Request for Geo-Analysis
8Copyright © 2013 InfoVista S.A. All rights reserved.
HUAWEI PCHR COLLECTION
1. Use “EXP CFGMML” command to export the MML scripts of the configuration data into the BAM folder
2. The CHRs are generated automatically and stored under the BAM in the following path:
RAN R12 & R13 /bam/common/fam/famlogfmt/pchr
3. The PCHR log will have either UCHR or PCHR word in the filenames e.g.
RAN R12 & R13 BSC0121_[PCHR]02Log20111010231746(DST)_20111010232743(DST).log.zip
Important: For R11 and above, please ensure that the file name has ‘PCHR’. File with ‘CHR’ string alone does NOT contain the performance call log and not supported in Xeus Pro.
4. Enable the CHRs Field
- If one of the fields is not enabled in the CHRs, use the following command to enable it:
- 1. In the LMT tool, execute the command SET UCHRCTRL (R11&above) in the Command Input field.
- 2. Click the “SELECT ALL” check box in the Type option drop down lists.
- 3. Run the command through a batch file only:
- Huawei R11 & above
SET UCHRCTRL:STATETYPE=ABNORMAL_ONLY-1&NORMAL_ONLY-1, DOMAINTYPE=CS_ONLY-1&PS_ONLY-1, FLOWTYPE=CONN_SETUP-1&RAB-1&DCCC-1&SHO-1&HHO-1&SYS_HO_OUT-1&RRC_RELEASE-1&STAT-1&NET_OPT-1, RRCCAUSE=ORIGINATING_CONVERSATIONAL_CALL-1&ORIGINATING_STREAMING_CALL-1&ORIGINATING_INTERACTIVE_CALL-1&ORIGINATING_BACKGROUND_CALL-1&ORIGINATING_SUBSCRIBED_TRAFFIC_CALL-1&TERMNT_CONVERSATIONAL_CALL-1&TERMNT_STREAMING_CALL-1&TERMNT_INTERACTIVE_CALL-1&TERMNT_BACKGROUND_CALL-1&EMERGENCY_CALL-1&INTER_RAT_CELL_RESELECTION-1&INTER_RAT_CELL_CHG_ORDER-1®ISTRATION-1&DETACH-1&ORIGINATING_HIGH_PRIOR_SIG-1&ORIGINATING_LOW_PRIOR_SIG-1&CALL_RE_ESTAB-1&TERMNT_HIGH_PRIOR_SIG-1&TERMNT_LOW_PRIOR_SIG-1&TERMNT_CAUSE_UNKNOWN-1&MBMS_RECEPTION-1&MBMS_PTP_RB_REQ-1;
9Copyright © 2013 InfoVista S.A. All rights reserved.
XEUS PRO TMR FILE PROCESSING
GPEH, PCHRMegamon Logs
File Decoder
Call State Engine
Geolocating & Binning
Cell Matching
Statistics Calculation
Plot Creation
Output Databases(Access)
Output Plots(MapInfo Tables)
INPUTOUTPUT
Identify Call Type, Call Events and
Release Reasons
10Copyright © 2013 InfoVista S.A. All rights reserved.
IMPORT TMR FILES
11Copyright © 2013 InfoVista S.A. All rights reserved.
IMPORTING TMR LOGS
Allow Filtering by Call End type or Call Messages to reduce output
database size
Set output database and summary parsing report name
and location
Enable Geo-Analysis to geolocating call position
Copyright © 2013 InfoVista S.A. All rights reserved.
www.infovista.com
QOS ANALYSISHigher QOS through analysis & comprehensive troubleshooting of abnormal events
13Copyright © 2013 InfoVista S.A. All rights reserved.
Cell RF Classification
Good
Poor
Distribution of received signal strength
Cell Analysis – Health Check
14Copyright © 2013 InfoVista S.A. All rights reserved.
RF Elements in the cell
Power Usage & System Resources
Cell Utilization
15Copyright © 2013 InfoVista S.A. All rights reserved.
Overall Throughput Analysis
Best/Worst Cell Analysis
Throughput Analysis
16Copyright © 2013 InfoVista S.A. All rights reserved.
Detail Dropped Analysis with slicing and drill-down support
Drill-down analysis
Blocked & Dropped Analysis
Copyright © 2013 InfoVista S.A. All rights reserved.
www.infovista.com
USER QUALITY MANAGEMENTManage & Improve your most important clients call quality
18Copyright © 2013 InfoVista S.A. All rights reserved.
VIP Summary for selected IMSI Details call with decoded messages
VIP Call Trace Analysis
19Copyright © 2013 InfoVista S.A. All rights reserved.
Subscriber KPI Analysis
20Copyright © 2013 InfoVista S.A. All rights reserved.
Phone Profiling – Comparing Phone Performance
Phone Profiling
21Copyright © 2013 InfoVista S.A. All rights reserved.
Compare Signal Strength between two Phone models
Phone Profiling – Distribution Chart
22Copyright © 2013 InfoVista S.A. All rights reserved.
Summary of State Transitions of all UEs
Smart Phone Analysis (*GPEH ONLY)
23Copyright © 2013 InfoVista S.A. All rights reserved.
Signaling vs RRC State Transition Statistics
Smart Phone Analysis (*GPEH ONLY)
Copyright © 2013 InfoVista S.A. All rights reserved.
www.infovista.com
LIVE GEO-ANALYSISSwiftly Geo-Locate calls & pin-point areas that require optimization
25Copyright © 2013 InfoVista S.A. All rights reserved.
• GeoAnalysis feature for geo-locating of UE
• User-defined Thematic Plotting
Bin Plots from live UE measurement
Coverage Analysis
26Copyright © 2013 InfoVista S.A. All rights reserved.
Bin Plot Analysis and Call SearchDisplay Measurements and KPI for selected bin on Map
Able to search call that pass through the bin
Select plot bin
Search Calls that pass through the
bin
Bin- Plot Analysis
27Copyright © 2013 InfoVista S.A. All rights reserved.
User Positioning on Normal/Abnormal Calls
Abnormal Call Details
User Positioning
Copyright © 2013 InfoVista S.A. All rights reserved.
www.infovista.com
NETWORK OPTIMIZATIONIncrease optimization efficiency through detailed neighbor optimization , pilot pollution & coverage analysis
29Copyright © 2013 InfoVista S.A. All rights reserved.
Suggest Neighbor Addition, Removal and Re-ranking
User-definable parameter for neighbor optimization algorithm
Neighbor Optimization
30Copyright © 2013 InfoVista S.A. All rights reserved.
Pilot-pollution analysis
31Copyright © 2013 InfoVista S.A. All rights reserved.
Polluted Cell Polluter Cell and Pollution Event
Count
• Identify Polluted Cells & Polluters
• Input for Antenna Tilting
Pilot-pollution analysis – Map View
32Copyright © 2013 InfoVista S.A. All rights reserved.
Call Setup Distance
Coverage Zone on Map
Cell Coverage Details
Cell Coverage Analysis
Copyright © 2013 InfoVista S.A. All rights reserved.
www.infovista.com
SUPPORTING FEATURES
34Copyright © 2013 InfoVista S.A. All rights reserved.
Search by various filters
Search Result with detail information
Call or Event Search
35Copyright © 2013 InfoVista S.A. All rights reserved.
Excel Report Designer and CreatorExcel Report Template Editor where user can drag-drop drop the metrics to the report template
Reporting feature and template available for all modules
Drag & drop metrics
Excel file Editor
Flexible Reporting Module
Copyright © 2013 InfoVista S.A. All rights reserved.
www.infovista.com
TASK AUTOMATION MODULE (TAM)Automated parsing of TMR logs
37Copyright © 2013 InfoVista S.A. All rights reserved.
1. Scheduling with Auto FTP & Parsing
Network Traffic Measurement Log from OSS
4. User can copy the parsed datasets to local machine to
work on them offline
2. Parsed datasets & reports are stored in the workstation file-system
Workstation
3. Xeus Pro user can work locally on the
workstation with the parsed datasets
Aexio Xeus Task Automation Module (TAM)
38Copyright © 2013 InfoVista S.A. All rights reserved.
Processor : Intel® Xeon® 8-Core (E5-2667, E5-2630, E5-2620)
Operating System : Windows® 7 Professional 64 bit
Memory : 16 (2 x 8GB) or 32GB (4 x 8GB) DDR3 RDIMM
Memory, 1600MHz
Hard Drive : 4 X 1TB Serial Attached SCSI hard
drive (10K RPM)
Drive Controller : SAS hard drives with RAID 10
configurations
Task Automation Module (TAM) Recommended Specs
39Copyright © 2013 InfoVista S.A. All rights reserved.
TAM
WORKSTATION
Multi Vendor
OSS or RNCs
Gigabit
Ethernet LANLAN
TAM
WORKSTATION
TAM
WORKSTATION
40Copyright © 2013 InfoVista S.A. All rights reserved.
OTHER SUPPORTED VENDORSLayer3 Message Flow with Internal Message Visibility and RF Measurements
41Copyright © 2013 InfoVista S.A. All rights reserved.
Layer 3 Messages & Events
Huawei CHR Log associated for the call
Measurement Chart
XEUS – Huawei CHR Views
42Copyright © 2013 InfoVista S.A. All rights reserved.
Layer 3 Messages & Internal RNC
Messages
External Message DetailsInternal RNC Message Details
XEUS – NSN Megamon Views
43Copyright © 2013 InfoVista S.A. All rights reserved.
Layer 3 Messages & Events
ZTE CTS log internal message of the call
Measurement Chart
XEUS – ZTE CTS Views
44Copyright © 2013 InfoVista S.A. All rights reserved.
Layer 3 Messages & Internal RNC
Messages
Internal RNC Message Details
XEUS – Ericsson LTE eNodeB UE/Cell Trace Views
www.infovista.com
Copyright © 2013 InfoVista S.A. All rights reserved.
Worldwide HeadquartersInfoVista S.A.6, rue de la Terre de Feu91952 Courtaboeuf CedexFrance
Tel: +33 (0)1 64 86 79 00Fax: +33 (0)1 64 86 79 79
Americas HeadquartersInfoVista Corporation12950 Worldgate Drive, Suite 250Herndon, VA 20170United States
Tel: +1 703 435 2435 Fax: +1 703 435 5122
Asia-Pacific HeadquartersInfoVista (Asia-Pacific) Pte LtdBlock 750C, #03-16/17, Chai Chee RoadTechnoPark@Chai CheeSingapore 469003
Tel: +65 6449 7641Fax: +65 6449 3054