Brief overview of MAJOR CHANGES
in 2013 Title 24, Part 6 for Residential
HVAC (new construction, additions
and alterations).
Changes in Scope and Application
4/19/2013 3
Welcome
Changes in Scope and Application
●When, Where and Why?
●TDV Changes
●New Software and HERS Registration Procedures
HVAC: New Construction
HVAC: Additions and Alterations
HVAC: Forms
Wrap Up
When, Where..
When (current schedule):
Any projects that apply for permit on or after January
1, 2014 will be subject to the 2013 Standards.
Exception: Nonresidential Registry January 1, 2015
Where can you find?
Marked version of the 2013 Standards, ACM, 2nd
draft version of the Residential Manual and
compliance forms.
http://www.energy.ca.gov/title24/2013standards/
4 4/19/2013
20
13
Re
s H
VA
C S
tan
da
rds O
ve
rvie
w f
or
WH
PA
and Why?
2020
All California new residential
construction zero net energy
Low-income homes energy
efficient
5 4/19/2013
2013 R
es H
VA
C S
tandard
s O
verv
iew
for
WH
PA
1.48 1.6
1.9
4.11
4.09
6.23
2008 2013
Average TDV Energy Multipliers
Natural Gas Propane Electricity
TDV Changes
6 4/19/2013
Source: Ken Nittler, Nov 2011 CABEC conference
2013 R
es H
VA
C S
tandard
s O
verv
iew
for
WH
PA
New simulation engine CSE
(California Simulation Engine)
Compliance Manager software from
CEC to provide Standard/Proposed
rules for modeling
All software vendors will use same
plug in to Compliance Manager
software
Creation of CF-1R will require internet
access to CEC’s Compliance
Manager.
HERS registration process will include
uploading the CF-1R from the CEC for
registration and signatures per current
procedures.
Performance (CF-1R-PRF-01)
New Software and HERS Registration Procedures
7 4/19/2013
This form is an example of CF-1R-PRF-01. Actual form still under construction.
20
13
Re
s H
VA
C S
tan
da
rds O
ve
rvie
w f
or
WH
PA
HERS registration process will include uploading the CF-1R from the CEC for
registration and signatures per current procedures.
Prescriptive New Buildings (CF-1R-NCB-01)
New HERS Registration Procedures
8 4/19/2013
20
13
Re
s H
VA
C S
tan
da
rds O
ve
rvie
w f
or
WH
PA
HERS registration process will include uploading the CF-1R from the CEC for
registration and signatures per current procedures.
CF-1R-PRSC-ALT-02 for CZ 1, 3, 4-7 and 16:
Duct Leakage
Airflow and Fan Watt Draw
CF-1R-PRSC-ALT-03 for CZ 2 and 8-15:
Duct leakage
Airflow and Fan Watt Draw
Refrigerant Charge
Prescriptive HVAC Alterations
New HERS Registration Procedures
9 4/19/2013
20
13
Re
s H
VA
C S
tan
da
rds O
ve
rvie
w f
or
WH
PA
HVAC: New Construction
4/19/2013 10
Welcome
Changes in Scope and Application
HVAC: New Construction
●Heating and Cooling Equipment
●IAQ Ventilation
●Ducts
●HERS
HVAC: Additions and Alterations
HVAC: Forms
Wrap Up
“New” Mandatory New Package “A”
Heating and Cooling Equipment
11 4/19/2013
After January 1, 2015: DX air conditioners
<65,000 Btuh 14 SEER or better;
weatherized central furnaces <225,000
Btuh 81% AFUE; package heat pumps 8.0
HSPF, split heat pumps 8.2 HSPF.
Design Conditions: 68 degree F for heating.
150.0(h)2
Outdoor condensing unit: at least 5’ from
the outlet of any dryer vent. 150.0(h)3
Refrigerant and piping insulation changes.
150.0(h)4, 150.0(j)3B
Systems that utilize forced air ducts for
cooling to meet airflow and fan watt draw
requirements. 150.0(m)13B
Systems that utilize automatic zonal control
must meet airflow and fan watt draw
requirements. 150.0(m)15
Supplemental heating allowed with sizing
and timing controls. 150.1(c)6
Refrigerant charge HERS tested and
verified for CZ 2, 8-15 (similar to 2008),
weigh-in approach for systems not able to
follow 150.1(c)7 added.
Central forced air system fans used in
central fan integrated ventilation system to
be HERS tested and verified for 350 CFM/
ton and 0.58 watts per CFM (similar to
2008). 150.1(c)10
Higher than minimum SEER ratings to be
HERS verified. 150.1(b)4Bi
2013 R
es H
VA
C S
tandard
s O
verv
iew
for
WH
PA
“New” Mandatory New Package “A”
IAQ Ventilation
12 4/19/2013
2013 R
es H
VA
C S
tandard
s O
verv
iew
for
WH
PA
Continuous operation of central
forced air system not allowed as
IAQ approach
Whole building IAQ ventilation
airflow performance to be HERS
tested and verified. 150.0(o)
Night Ventilation: Whole house
fan CZ 8-14. 150.1(c)12
“New” Mandatory New Pacakge “A”
Ducts
13 4/19/2013
2013 R
es H
VA
C S
tandard
s O
verv
iew
for
WH
PA
Minimum R-6 duct insulation. 150.0(m)1
(150.0(m)11ANSI/SMACNA-006-2006
HVAC Duct Construction Standard.
150.0(m)1
HERS duct testing in all CZ. 150.0(m)11
Air filtration devices for mechanical systems
that supply air through 10 sf or more of duct
work. 150.0(m)12
Hole for static pressure probe (HSPP), or
permanently installed static pressure probe
(PSPP) in supply plenum, HERS tested and
verified .150.0(m)13A
Return ducts sized per Table 150.0-C and
150.0-D, or be HERS tested and verified for
350 CFM/ ton and 0.58 watts per CFM.
150.0(c)13B alt.
Duct R-values 150.1(c)9:
CZ 1-10, 12-13 is R-6
CZ 11, 14-16 is R-8
HVAC system bypass ducts not allowed
prescriptively. 150.1(c)13
Ducts not insulated because in conditioned
space to be HERS verified with duct
leakage to outside procedure. 150.1(c)9
“New” Mandatory Package “A”
HERS
14 4/19/2013
2013 R
es H
VA
C S
tandard
s O
verv
iew
for
WH
PA
Systems that utilize forced air ducts for
cooling to meet airflow and fan watt draw
requirements. 150.0(m)13B
Systems that utilize automatic zonal control
must meet airflow and fan watt draw
requirements. 150.0(m)15
Whole building IAQ ventilation airflow
performance to be HERS tested and
verified. 150.0(o)
HERS duct testing in all CZ. 150.0(m)11
Hole for static pressure probe (HSPP), or
permanently installed static pressure probe
(PSPP) in supply plenum, HERS tested and
verified .150.0(m)13A
Return ducts sized per Table 150.0-C and
150.0-D, or be HERS tested and verified for
350 CFM/ ton and 0.58 watts per CFM.
150.0(c)13B alt.
Refrigerant charge HERS tested and
verified for CZ 2, 8-15 (similar to 2008),
weigh-in approach for systems not able to
follow 150.1(c)7 added.
Central forced air system fans used in
central fan integrated ventilation system to
be HERS tested and verified for 350 CFM/
ton and 0.58 watts per CFM (similar to
2008). 150.1(c)10
Higher than minimum SEER ratings to be
HERS verified. 150.1(b)4Bi
Ducts not insulated because in conditioned
space to be HERS verified with duct
leakage to outside procedure. 150.1(c)9
HVAC: Additions and Alterations
4/19/2013 15
Welcome
Changes in Scope and Application
HVAC: New construction
HVAC: Additions and Alterations
●Heating and Cooling Equipment
●IAQ Ventilation
●Ducts
●HERS
HVAC: Forms
Wrap Up
Addition less than 1,000 sf or less are exempt from whole-building airflow requirements, all other applicable requirements still apply
Greater than 1,000 sf, all apply
Ducts extended from existing system that are less than 40 linear feet: R-6 duct insulation.
Over 40 linear feet, new AND existing ducts must meet mandatory and prescriptive requirements.
New equipment (not a repair) must meet all applicable measures as for new construction, including all HERS measures.
Existing and new ducts of new/altered system to be HERS tested and verified.
If existing system extended, equipment need not comply with Part 6. Heating capacity must be adequate to meet CBC Section 1204.1
If refrigerant-containing system components altered, setback thermostat required.
HVAC: Additions and Alterations
16 4/19/2013
20
13
Re
s H
VA
C S
tan
da
rds O
ve
rvie
w f
or
WH
PA
HVAC Equipment
IAQ Ventilation
Ducts
HERS
HVAC: Alterations Using Performance Method
To take performance credit for improving a feature of existing (pre-
altered) condition, the feature must be verified by a HERS rater before
construction and permit submittal. Otherwise, the appropriate prescriptive
or mandatory efficiency level for that measure is used to set the
“standard” design in the compliance software. 150.2(b)1D
For further details, see the 2013 Residential ACM Reference Manual.
20
13
Re
s H
VA
C S
tan
da
rds O
ve
rvie
w f
or
WH
PA
17 4/19/2013
HVAC: Forms
4/19/2013 18
Welcome
Changes in Scope and Application
HVAC: New construction
HVAC: Additions and Alterations
HVAC: Forms
●Heating and Cooling Equipment
●IAQ Ventilation
●Ducts
●HERS
Wrap Up
HVAC Forms: CF-2R Certificate of Installation (previously known as CF-6R)
20
13
Re
s H
VA
C S
tan
da
rds O
ve
rvie
w f
or
WH
PA
HVAC Forms: CF-3R Certificate of Verification (previously known as CF-4R)
20
13
Re
s H
VA
C S
tan
da
rds O
ve
rvie
w f
or
WH
PA
Thank you
20
13
Re
s H
VA
C S
tan
da
rds O
ve
rvie
w f
or
WH
PA