2013-06-26 pi schneider - profibusgroup.com · uk profibus group karsten schneider pi chairman uk,...
TRANSCRIPT
UK PROFIBUS
Group
Karsten SchneiderPI Chairman
UK, June 2013
20th Anniversary Celebration Conference
PI Overview
3
© PROFIBUS Nutzerorganisation
Leading Technologies
Organization Technologies
Fieldbus Ethernet
RegionalPI Associations
PI CompetenceCenter
PI Training Center
PI Testlabore
More than 1.400 member companies world wide!
WGs
PI (PROFIBUS & PROFINET International)
Proxy Technology
Sensors & Actuators
4
© PROFIBUS Nutzerorganisation
PI World Wide
Regional Operations30CompetenceCenter50TrainingCenter26Test Labs11
LatestNode Figures
6
© PROFIBUS Nutzerorganisation
PROFINET & PROFIBUS nodes
7
© PROFIBUS Nutzerorganisation
PROFIsafe nodes
PROFINET
Highlights
9
© PROFIBUS Nutzerorganisation
PROFINET specification history
2004 2005 2006 2007 2008 2009 2010
Simple device exchangeNetwork configurationSwitch IntegrationFiber Optics
Network diagnosisTopologyMedia RedundancyTime synchronizationMaintenance NE107
Fast Start Up PerformanceOptimization
Fiber Optic Enhancements
PROFINET in PA Basic functions
Specification
FunctionEnhancements
PN V2.1 PN V2.2 PN V2.3PN V2.0
PN V1.0Whitepaper
PN V1.3
Applications
Standard
RobotsHighestSpeed / Process
Basic Functionality
…with PROFIenergy
11
© PROFIBUS Nutzerorganisation
PROFIenergy: Transparency & Shutdown
Shut
dow
nTr
ansp
aren
cy Read measured data Many devices implicitly detectthe energy (e.g. FCs)
Basis for active energy management
Shutdown during unplanned idle timesTime and duration of idle timeare unknown
Shutdown during short idle times Optimized energy savings at fast availability
Shutdown during long idle times Maximum energy savings
The key to accessing a savings potential not used so far
12
© PROFIBUS Nutzerorganisation
Cost savings through omission of external hardware
Energy saving even in short pauses thanks to granular switching
High system reliability through coordinated switching
Investment safeguarding through simple reaction-free integration into existing standards
Free selection of device through vendor-independent standard
PROFIenergy permits energy saving in breaks through switching-off of non-required loads!
Five good reasons for PROFIenergy
Controller HMI
Distributed I/O
Motion Control & Drives
DC24V
13
© PROFIBUS Nutzerorganisation
Development of PROFIenergy
Customers start to integrate
PROFIenergy
2009
Definition phase White Paper Technical Specification
2010
First products are available on the
market2011
2012
Number of devices increases sharply
PROFIenergy Specification V 1.1
PROFIBUS & PROFINET
for Process Automation
15
© PROFIBUS Nutzerorganisation
PROFIBUS in Process Industry
PROFIBUS PAThe Standard in Process Automation
Communication andEnergy for field devices over the bus
Intrinsically safe for use in hazardous areas
Configuration of the devices over the bus
PA device profile
16
© PROFIBUS Nutzerorganisation
PA Profil
PA Profil 3.02 – a big step!simplified diagnostics: The right information
for the right person at the right time
simplified device exchange: easier than 4…20mA devices
simplified commissioning: Faster parameter transmission
Not just a displacement of 4…20mA, it takes process automation to an entire new level
More and more device vendors implement PROFIBUS PA!
17
© PROFIBUS Nutzerorganisation
Extensions for PROFINET in PA
Fieldbus integrationDCS
HART
PROFIBUS PA
FF H1
PROFIBUS DP
PROFINET
Configuration in Run (CiR)
DCS
Remote I/O Proxy
Sequence of Events
System Master Clock(GPS, DCF77, …)
Controller 1 Controller 2 Controller 3
Proxy
Device Device
BackupClock Master
RedundancyRedundant Controller
PrimaryBackup
Redundant Network
Device with redundant connectivity
Device with singularconnectivity
FDI
19
© PROFIBUS Nutzerorganisation
Field device as information source
Operator
Maintenance-personal
Manufacture, Expert
Technician, Engineer
Field device
20
© PROFIBUS Nutzerorganisation
Commissioning
Device Integration
Field Device
Automation System
Engineering
Operation
Maintenance
…
Commissioning
With the Device Integration, a host can get access (from a central location) to the device functions and information.
21
© PROFIBUS Nutzerorganisation
A Common Approach
Device Package
HarmonizedEDD
Advanced Features(optional)
EDDL
Harmonized
FDT GroupFieldbus FoundationHART Communication FoundationOPC FoundationPROFIBUS/PROFINET International
ABB InvensysEmerson SiemensEndress+Hauser YokogawaHoneywell
22
© PROFIBUS Nutzerorganisation
FDI Device Package
Device Package
UIP(optional)
Attach-ments
Electronic Device Description Language
(EDDL)
Windows Presentation Foundation
(WPF)
ManualsCertificatesProtocol specific Files (GSD(ML), etc.)
EDDFDI encoded file format
Device Definition (Def)Business logic (BL)User Interface (UID)
Goal: one device driver!
Programmed User InterfaceDevice Applications
23
© PROFIBUS Nutzerorganisation
System integration
Manages Device Packages Manages and provides device data Processes device specific user
interfaces: Mandatory, EDDL based UID Optional, WPF based UIP
Processes EDD Business Logic Communicates with devices
OPC UA Services
Communication Server
OPC UA Services
FDI Client
FDI Server
Device Package
EDDL UIPOptional
Attach-ments
FDI Host
DeviceDefinitionBusiness LogicCommunication
User InterfacesDevice Applications
EDD Engine
InformationModel
UIDRenderer
UIPHosting
24
© PROFIBUS Nutzerorganisation
NAMUR/WIB Key Requirements
UIP
HarmonizedEDDL
(IEC 61804-3)PROFIBUS
HARTFoundationFieldbus
FDIDevice Package
developmentControl systemStandard
FDI IDE
Package
EDD UIP
Package
EDD UIP
Package
EDD UIP
Certification/Registration
The harmonized EDDL is always and exclusively used in FDI Device Packages.
In addition use of standard Host Components and IDE improve interoprability.
FDI Device Packages always make use of harmonized EDDL.
24
OPC UA Services
Communication Server
OPC UA Services
FDI Client
FDI Server
FDI Host
EDD Engine
InformationModel
UIDRenderer
UIPHosting
25
© PROFIBUS Nutzerorganisation
Summary
FDI fulfills NAMUR requirementsProcess automation vendors support FDI developmentDraft specifications are availableIEC Standardization has been initiatedEDDL has been harmonized across protocolsFDT FDI Interoperability is ensured“Foundations” cooperate in FDICooperation to complete and promote FDI Technology
Thank You!