2012 12-04 sbc+pres

12
David Prouty High School Schematic Design Faculty & SBC Presentations December 4 th , 2012

Upload: aaronkeyes

Post on 16-Apr-2017

307 views

Category:

Education


0 download

TRANSCRIPT

Page 1: 2012 12-04 sbc+pres

David Prouty High School Schematic Design

Faculty  & SBC PresentationsDecember 4th, 2012

Page 2: 2012 12-04 sbc+pres

D AV I D P R O U T Y H I G H S C H O O LS P E N C E R E A S T B R O O K F I E L D R E G I O N A L , M A S S A C H U S E T T S

S I T E P L A N DECEMBER 2012

RAMP TO TRACK: 690’ LONG/50’ GRADE CHANGE

RAMP TO UPPER FIELD: 588’ LONG/42’ GRADE CHANGE

LLLLLLLLLLLLLLLLLLLLLLLLL AAAAAAAAAAAAAAAAAAAAAAAAAAAA NNNNNNNNNNNNNNNNNNNNN DEC

RAMP TO TRACK: 690’ LONG/50’ GR

RRAAMMPP TTOO UUPPPPEERR FFIIEELLDD:: 558888’’ LLOONNGG//4422’’ GGRRRRR

Page 3: 2012 12-04 sbc+pres

D AV I D P R O U T Y H I G H S C H O O LS P E N C E R , M A S S A C H U S E T T S

S I T E P L A N DECEMBER 2012PARKING: 226

rbell
Typewritten Text
Page 4: 2012 12-04 sbc+pres

D AV I D P R O U T Y H I G H S C H O O LS P E N C E R , M A S S A C H U S E T T S

S I T E P L A N DECEMBER 2012PARKING: 213

Page 5: 2012 12-04 sbc+pres

DAVID PROUTY HIGH SCHOOLExisting - Birds Eye View DATE: 12/04/2012

Spencer, MA

Page 6: 2012 12-04 sbc+pres

DAVID PROUTY HIGH SCHOOLProposed - Birds Eye View DATE: 12/04/2012

Spencer, MA

Page 7: 2012 12-04 sbc+pres

December 04, 2012 - School Building Committee Meeting

Spencer, MA

David Prouty High School

Main & Upper Floor Plans

Page 8: 2012 12-04 sbc+pres

December 04, 2012 - School Building Committee Meeting

Spencer, MA

David Prouty High School

Lower Floor Plan

Page 9: 2012 12-04 sbc+pres

DPDP

UP

WO

DW

DW

DW DW

REF

FRZ

WO

DW

DW

DW DW

REF

DPDP

DN

REF

EXISTING DOMESTIC HOTWATER HEATER

EXISTING ELECTRICAL SERVICE

EXISTING DOMESTICHOT WATER HEATER

E

B2

C

G

G

A

ROOF OFPORTION A

PROVIDE 6 TEMPORARYCLASSROOMS PRIOR TOCOMMENCEMENT OF STEP ?

TEMPORARYCLASSROOM

TEMPORARYCLASSROOM

TEMPORARYCLASSROOM

TEMPORARYCLASSROOM

TEMPORARYCLASSROOM

TEMPORARYCLASSROOM

A1

PORTION G STARTS07/01/2015 THRU 08/15/2015

NEW BOILER PLANT & MAINELECTRICAL ROOMS STARTS ON04/01/2014 THRU 07/15/2015

PORTION B2 STARTSON 07/01/2015 THRU08/15/2015

PORTION A1 STARTS ON07/01/2014 THRU 08/01/2015

B3B4

A2

PORTION A2 STARTS ON06/15/2015 THRU 08/01/2015

PORTION B3 STARTS ON06/01/2014 THRU 08/01/2014

PORTION B4 STARTS ON06/01/2014 THRU 08/01/2015

EXISTING PHONESERVICE

EXISTING FIRE ALARMPANEL

EXISTING MASTERCLOCK & P.A.

EXISTING FIRE ALARMANNUNCIATOR PANEL

EXISTING EMERGENCYELECTRICAL PANEL

EXISTING EMERGENCYGENERATOR

EXISTING UNDERGROUNDOIL TANK

EXISTING ELECTRICALPANELS

D

D1

E1E

G

B2

C

A

B

ROOF OFPORTION A1

PORTION G STARTS 07/01/2015THRU 08/15/2015

PORTION D1 STARTS12/26/2014 THRU 08/15/2015

PORTION B2 STARTS ON07/01/2015 THRU 08/15/2015

PORTION B STARTS ON12/26/2014 THRU 07/01/2015,NIGHT SHIFTS ONLY

PORTION E STARTS ON07/01/2015 THRU 08/15/2015

PORTION E1 STARTS ON04/14/2015 THRU 08/15/2015

PORTION D STARTS12/26/2014 THRU 08/01/2015

PORTION A STARTS ON04/01/2014 THRU 07/15/2015

EXISTING CATV SERVICE

EXISTING ELECTRICALPANELS

B2

G

B

AROOF OF

PORTION AROOF OF

PORTION A1

PORTION G STARTS07/01/2015 THRU 08/15/2015

PORTION B2 STARTS ON07/01/2015 THRU 08/15/2015

PORTION A STARTS ON04/01/2014 THRU 07/15/2015

PORTION B STARTS ON12/26/2014 THRU 07/01/2015,NIGHT SHIFTS ONLY

PHASING LEGEND

OWNER OCCUPIEDNO W ORK

CONTRACTOR HAS POSSESSIONWORK CAN ONLY OCCUR OFF HOURS

CONTRACTOR HAS FULL POSSESSIONNEW CONSTRUCTION

OWNER OCCUPIEDWORK SUBSTANTIALLY COMPLETED PRIOR

Drawn By:

Checked By:Scale:Date:Professional Seal

KEY PLAN

1/32" = 1'-0"

12/4/2012 3:51:52 PM

PH1.1

PHASING PLANS-PHASE 1

DC

KM

12/03/2012

DAVID PROUTY HIGHSCHOOL

SPENCER, MA

PROJECTNORTH 1/32" = 1'-0"

1PHASE 1-GROUND FLOOR

1/32" = 1'-0"2

PHASE 1-FIRST FLOOR 1/32" = 1'-0"

3PHASE 1-SECOND FLOOR

Page 10: 2012 12-04 sbc+pres

DPDP

UP

WO

DW

DW

DW DW

REF

FRZ

WO

DW

DW

DW DW

REF

DPDP

DN

REF

PHASING LEGEND

OWNER OCCUPIEDNO W ORK

CONTRACTOR HAS POSSESSIONWORK CAN ONLY OCCUR OFF HOURS

CONTRACTOR HAS FULL POSSESSIONNEW CONSTRUCTION

OWNER OCCUPIEDWORK SUBSTANTIALLY COMPLETED PRIOR

EXISTING DOMESTIC HOTWATER HEATER

EXISTING ELECTRICAL SERVICE

EXISTING DOMESTICHOT WATER HEATER

E

B2

C

G

G

A

ROOF OFPORTION A

TEMPORARYCLASSROOM

TEMPORARYCLASSROOM

TEMPORARYCLASSROOM

TEMPORARYCLASSROOM

TEMPORARYCLASSROOM

TEMPORARYCLASSROOM

PORTION G COMPLETED08/15/2015

A2

H

PORTION H STARTS 07/15/2015(DOUBLE SHIFTS) THRU08/15/2015, THEN NIGHT SHIFTSONLY FROM 08/16/2015

PORTION B2 COMPLETED08/15/2015

A1

B3B4

EXISTINGPHONESERVICE

EXISTING FIRE ALARMPANEL

EXISTING METERCLOCK & P.A.

EXISTING FIRE ALARMANNUNCIATOR PANEL

EXISTING EMERGENCYELECTRICAL PANEL

EXISTING EMERGENCYGENERATOR

EXISTING UNDERGROUNDOIL TANK

EXISTING ELECTRICALPANELS

D

D1

E1

G

B2

C

A

B

PORTION G COMPLETEDBY 08/15/2015

PORTION D3 STARTS06/25/2016 THRU 08/25/2016

H

D3

I1

D2

PORTION H STARTS07/16/2015 THRU 07/16/2016

PORTION D1 COMPLETEDBY 08/15/2015

PORTION I1 STARTS05/15/2016 THRU 08/15/2016,KITCHEN RENOVATION ONLYLONGER THAN SUMMER

PORTION D2 STARTS07/01/2015 THRU 05/15/2016,INTO PHASE 3

PORTION B2 COMPLETEDBY 08/15/2015

E

OWNER?E2

ROOF OFPORTION A1

EXISTING CATV SERVICE

EXISTING ELECTRICALPANELS

B2

G

B

AROOF OF

PORTION A

PORTION G COMPLETEDBY 08/15/2015

PORTION B2 COMPLETEDBY 08/15/2015

H

PORTION H STARTS07/16/2015 THRU 07/16/2016

ROOF OFPORTION A1

Drawn By:

Checked By:Scale:Date:Professional Seal

KEY PLAN

1/32" = 1'-0"

12/4/2012 3:48:45 PM

PH2.1

PHASING PLANS-PHASE 2

DC

KM

12/03/2012

DAVID PROUTY HIGHSCHOOL

SPENCER, MA

PROJECTNORTH 1/32" = 1'-0"

1PHASE 2-GROUND FLOOR

1/32" = 1'-0"2

PHASE 2-FIRST FLOOR 1/32" = 1'-0"

3PHASE 2-SECOND FLOOR

Page 11: 2012 12-04 sbc+pres

DP

REF

DPDP

UP

WO

DW

DW

DW DW

REF

FRZ

WO

DW

DW

DW DW

REF

DPDP

DN

REF

EXISTING DOMESTIC HOTWATER HEATER

EXISTING ELECTRICAL SERVICE

EXISTING DOMESTICHOT WATER HEATER

E

B2C

G

G

A

ROOF OFPORTION A

PROVIDE 6 TEMPORARYCLASSROOMS PRIORTO COMMENCEMENTOF STEP ???

TEMPORARYCLASSROOM

TEMPORARYCLASSROOM

TEMPORARYCLASSROOM

TEMPORARYCLASSROOM

TEMPORARYCLASSROOM

TEMPORARYCLASSROOM

A2

H

J

PROVIDE TEMPORARYWALL AS REQUIRED PORTION J STARTS 07/16/2016

THRU TO 02/20/2017

A1

B3B4

PHASING LEGEND

OWNER OCCUPIEDNO W ORK

CONTRACTOR HAS POSSESSIONWORK CAN ONLY OCCUR OFF HOURS

CONTRACTOR HAS FULL POSSESSIONNEW CONSTRUCTION

OWNER OCCUPIEDWORK SUBSTANTIALLY COMPLETED PRIOR

EXISTING PHONESERVICE

EXISTING FIRE ALARMPANEL

EXISTING METERCLOCK & P.A.

EXISTING FIRE ALARMANNUNCIATOR PANEL

EXISTING EMERGENCYELECTRICAL PANEL

EXISTING EMERGENCYGENERATOR

EXISTING UNDERGROUNDOIL TANK

EXISTING ELECTRICALPANELS

D

D1

E1E2

G

B2

C

A

B

ROOF OFPORTION A

H

D3

I1

D2

PORTION I1 COMPLETED BY08/15/2016, KITCHENRENOVATION ONLY LONGERTHAN SUMMER

PORTION D2 COMPLETEDBY 05/15/2016

J

I2

PORTION J STARTS 07/16/2016THRU TO 02/20/2017

PORTION I2 STARTS07/16/2016 THRU 02/20/2017

PROVIDE TEMPORARY WALLAS REQUIRED

K

PORTION K STARTS ON07/16/16 THRU 02/20/2017

E

OWNER?

ROOF OFPORTION A1

EXISTING CATV SERVICE

EXISTING ELECTRICALPANELS

B2

G

B

AROOF OF

PORTION A

ROOF OFPORTION A

H

JPROVIDE TEMPORARYWALL AS REQUIRED

PORTION J STARTS 07/16/2016THRU TO 02/20/2017

ROOF OFPORTION A1

Drawn By:

Checked By:Scale:Date:Professional Seal

KEY PLAN

1/32" = 1'-0"

12/4/2012 3:49:16 PM

PH3.1

PHASING PLANS-PHASE 3

DC

KM

12/03/2012

DAVID PROUTY HIGHSCHOOL

SPENCER, MA

1/32" = 1'-0"1

PHASE 3-GROUND FLOORPROJECTNORTH

1/32" = 1'-0"2

PHASE 3-FIRST FLOOR 1/32" = 1'-0"

3PHASE 3-SECOND FLOOR

Page 12: 2012 12-04 sbc+pres

DP

REF

DPDP

UP

WO

DW

DW

DW DW

REF

FRZ

WO

DW

DW

DW DW

REF

DPDP

DN

REF

EXI STEL EV.

PHASING LEGEND

OWNER OCCUPIEDNO W ORK

CONTRACTOR HAS POSSESSIONWORK CAN ONLY OCCUR OFF HOURS

CONTRACTOR HAS FULL POSSESSIONNEW CONSTRUCTION

OWNER OCCUPIEDWORK SUBSTANTIALLY COMPLETED PRIOR

EXISTING DOMESTIC HOTWATER HEATER

EXISTING ELECTRICAL SERVICE

EXISTING DOMESTICHOT WATER HEATER

E

B2

C

G

G

B

ROOF OFPORTION A

TEMPORARYCLASSROOM

TEMPORARYCLASSROOM

TEMPORARYCLASSROOM

TEMPORARYCLASSROOM

TEMPORARYCLASSROOM

TEMPORARYCLASSROOM

A2

B3

H

J

PROVIDE TEMPORARYWALL AS REQUIRED

PORTION L STARTS 02/21/2017THRU TO 08/01/2017

L

N

PORTION N STARTS05/15/2017 THRU TO08/01/2017

P3

P3 STARTS 07/01/2017THRU TO 08/15/17

TT STARTS 07/01/2017THRU TO 08/15/17

A1

B4

A

EXISTING PHONESERVICEEXISTING FIREALARM PANEL

EXISTING METERCLOCK & P.A.

EXISTING FIRE ALARMANNUNCIATOR PANEL

EXISTING EMERGENCYELECTRICAL PANEL

EXISTING EMERGENCYGENERATOR

EXISTING UNDERGROUNDOIL TANK EXISTING ELECTRICAL

PANELS

D

D1

E1E2

G

B2

C

A

B

ROOF OFPORTION A1

H

M

I1

D2

J

I2

PORTION L STARTS 02/21/2017THRU TO 08/01/2017PROVIDE TEMPORARY WALL

AS REQUIREDL

P1

P2

T

PORTION P1 STARTS04/01/2017 THRU TO08/01/2017

PORTION P2 STARTS07/01/2017 THRU TO08/01/2017

PORTION T STARTS07/01/2017 THRU TO08/15/2017

PORTION M STARTS05/15/2017 THRU TO08/01/2017

N

K

PORTION N STARTS05/15/2017 THRU TO08/01/2017

E

EXISTING CATV SERVICE

EXISTING ELECTRICALPANELS

B2

G

B

AROOF OF

PORTION A

ROOF OFPORTION A1

H

J

PROVIDE TEMPORARYWALL AS REQUIRED

PORTION L STARTS 02/21/2017THRU TO 08/01/2017

L

Drawn By:

Checked By:Scale:Date:Professional Seal

KEY PLAN

1/32" = 1'-0"

12/4/2012 3:49:47 PM

PH4.1

PHASING PLANS-PHASE 4

DC

KM

12/03/2012

DAVID PROUTY HIGHSCHOOL

SPENCER, MA

PROJECTNORTH 1/32" = 1'-0"

1PHASE 4-GROUND FLOOR

1/32" = 1'-0"2

PHASE 4-FIRST FLOOR 1/32" = 1'-0"

3PHASE 4-SECOND FLOOR