200071 parameter: display interfaces.pdf · display format: 200071 working voltage: ac 80~260v test...

2
DROK AC 80-260V Digital Multimeter http://www.Droking.com Parameter: Display Format: 200071 Working voltage: AC 80~260V Test voltage: AC 80~260V Rated power: 0~22kW Operating frequency: 45~65Hz Measurement accuracy: 1.0 grade Wiring Diagram: Display Interface: Voltage Current Power Energy Measuring range 80~260V Display format: 80~260V Measuring range: 0~100A Display format: 0.00~99.99A Measuring range: 0~22kW Within 1kW: display 0.0~999.9W 1kW and above: display 1000`9999W 10kW and above: display 10.0~22.0kW Measuring range: 0~9999kWh Within 10kWH: display 0~9999WH 10kWH and above: display 10~9999kWH Over 9999kWh: display 0 CT Load Load CT

Upload: others

Post on 11-Nov-2020

28 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 200071 Parameter: Display InterfaceS.pdf · Display Format: 200071 Working voltage: AC 80~260V Test voltage: AC 80~260V Rated power: 0~22kW Operating frequency: 45~65Hz Measurement

DROK AC 80-260V Digital Multimeter

http://www.Droking.com

Parameter:

Display Format:

200071

Working voltage: AC 80~260V

Test voltage: AC 80~260V

Rated power: 0~22kW

Operating frequency: 45~65Hz

Measurement accuracy: 1.0 grade

Wiring Diagram:

Display Interface:

Voltage

Current

Power

Energy

Measuring range 80~260V

Display format: 80~260V

Measuring range: 0~100A

Display format: 0.00~99.99A

Measuring range: 0~22kW

Within 1kW: display 0.0~999.9W

1kW and above: display 1000`9999W

10kW and above: display 10.0~22.0kW

Measuring range: 0~9999kWh

Within 10kWH: display 0~9999WH

10kWH and above: display 10~9999kWH

Over 9999kWh: display 0

CT

Load

Load

CT

Page 2: 200071 Parameter: Display InterfaceS.pdf · Display Format: 200071 Working voltage: AC 80~260V Test voltage: AC 80~260V Rated power: 0~22kW Operating frequency: 45~65Hz Measurement

Key Functions:

Backlight Control

Short press to turn on/off backlight.Backlight on/off status automatically saved when power off.

Power/Energy Display Switch Short press to switch to display current power/cumulative energy consumption cumulative energy consumption.

Display status will be automatically saved when power off.

Energy Reset

Hold press for more than 3 seconds till the numbers of the energy display area flash, loose the key.

If short press , the energy data will be reset to 0 and exit reset mode.If over 10 seconds without any key action, the energy data won’t be reset to 0 and exit reset mode.

Power Alarm Hold press for more than 3 seconds till the numbers of the power display area flash, loose the key.

Note:

Please connect the wires strictly according to the wiring diagram.

The power of the load cannot exceed rated power.

Suitable for indoor use only, please do not use outdoor.

Not applicable for autotransformer, thyristor circuit or load.

Size:

57.5mm 38mm

37mm

67mm

57.5mm

62mm

67mm

52.5mm

65mm

53mm

24mm

62mmOverall:

Backside:

Opening:

Height:

Recommend product on Amazon:

100A/100mA AC Current Transformer

Any questions please contact us through Amazon:

Short press to +1 to the flashing lower digit.

Short press to switch the digit to be set. Alarm value cannot be set to exceed 2.5kW (factory default 2.5kW).

When finish setting, hold press for more than 3 seconds or over 10 seconds without any key actions, the data will be

automatically saved and exit the setting mode.

Power display area display currently set power alarm value, the lower digit start to flash.

Set Key

Backlight Control