20 - persona medical · sombra 8r series - features speech-focus™ null tracking directional...

56
2020 Product Specifications

Upload: others

Post on 22-Sep-2020

12 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

2020Product Specifications

Page 2: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

OSPL90 Maximum

OSPL90 @ 1600 Hz

HFAverage OSPL90

Peak Gain

HFA Full-On-Gain

Full-On-Gain @ 1600 Hz

Reference Test Gain

R.T.G @ 1600 Hz

Frequency Range (F1-F2)

THD at 500 Hz

800 Hz

1600 Hz

Equivalent Input Noise

Attack Time

Release Time

Battery Current Drain

Battery Life [312]*

Telecoil Sensitivity

ANSI S3.22-2003

2CC Coupler

117 dBSPL

N/A

113 dBSPL

60 dB

55 dB

N/A

35 dB

N/A

200 - 7500 Hz

< 1%

< 1%

< 1.5%

< 23 dB

10mS @ 2kHz*

20mS @ 2kHz*

0.84 mA

210 Hrs

87 dB SPL

IEC-118-0Ear Simulator

125 dBSPL

121 dBSPL

N/A

68 dB

N/A

63

N/A

43 dB

N/A

NA

NA

< 1.5%

< 23 dB

6mS @ 2kHz*

30mS @ 2kHz*

0.84 mA

210 Hrs

94 dB SPL

10

20

30

40

50

60

1000

Frequency in Hertz (Hz)

Gai

n in

dB

SP

L

200 500 2000 5000 8000

-10

0

10

20

30

40

50

60

70

80

90

100

110

125 250 500 1000 2000 4000 8000750 1500 3000 6000

Hea

ring

Leve

l In

Dec

ibel

s (d

B) l

lllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

Frequency in Hertz (Hz)

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

Open Ear

Occluded

Sombra 8r series - FeaturesSpeech-Focus™ Null Tracking Directional Microphones

ALL-IN-ONE™ Adaptive Speech Enhancement

Feedback path eliminator

Auto-Adaptation Feedback Shield™

Adaptive telecoil switch

Hydrocoat moisture barrier

Environmental Classification Noise Reduction

128 Channels Noise Reduction

16 Band Programming Control

Memory Change (4) Indicator - Adjustable Level & Frequency

Multi-function Manual VC / Memory Change

Speech Mapping Compatible w/ Graphic Equalizer

Low Battery Indicator

Wind Noise Reduction Algorithm

NOAH / NOAH Link Compatible

Wax-blocking RU connectors

Data Logging

®

OSPL90 CURVE

FREQUENCY RESPONSE CURVE

80

90

100

110

120

130

1000

Frequency in Hertz (Hz)

Out

put

in d

BS

PL

200 500 2000 5000 8000

407.339.2422 | [email protected]

Actual Size

SP_SOMBRA8R_3_20_rev- © PERSONA

Page 3: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

OSPL90 Maximum

OSPL90 @ 1600 Hz

HFAverage OSPL90

Peak Gain

HFA Full-On-Gain

Full-On-Gain @ 1600 Hz

Reference Test Gain

R.T.G @ 1600 Hz

Frequency Range (F1-F2)

THD at 500 Hz

800 Hz

1600 Hz

Equivalent Input Noise

Attack Time

Release Time

Battery Current Drain

Battery Life [312]*

Telecoil Sensitivity

ANSI S3.22-2003

2CC CouplerThin tube / Ear Hook

125/132 dBSPL

N/A

115/123 dBSPL

62/63 dB

55/55 dB

N/A

38/46 dB

N/A

200 - 7500 Hz

< 3%

< 3%

< 3%

< 24/23 dB

10mS @ 2kHz*

25mS @ 2kHz*

0.78/0.83 mA

215/210 Hrs

96/105 dB SPL

IEC-118-0Ear Simulator

Thin tube / Ear Hook

132/138 dBSPL

122/130 dBSPL

N/A

69/70 dB

N/A

63/63

N/A

44/53 dB

N/A

< 3%

< 3%

< 3%

< 24/23 dB

10mS @ 2kHz*

25mS @ 2kHz*

0.78/0.83 mA

215/210 Hrs

103/112 dB SPL

10

20

30

40

50

1000

Frequency in Hertz (Hz)

Gai

n in

dB

SP

L

200 500 2000 5000 8000

-10

0

10

20

30

40

50

60

70

80

90

100

110

125 250 500 1000 2000 4000 8000750 1500 3000 6000

Hea

ring

Leve

l In

Dec

ibel

s (d

B) llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

Frequency in Hertz (Hz)

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

Open Ear

Semi-Occluded w/ ZipTip

Earhook

Sombra 8s series - FeaturesSpeech-Focus™ Null Tracking Directional Microphones

ALL-IN-ONE™ Adaptive Speech Enhancement

Feedback path eliminator

Auto-Adaptation Feedback Shield™

Adaptive telecoil switch

Hydrocoat moisture barrier

Environmental Classification Noise Reduction

128 Channels Noise Reduction

16 Band Frequency Programming Control

Memory Change (4) Indicator - Adjustable Level & Frequency

Multi-function Manual VC / Memory Change

Speech Mapping Compatible w/ Graphic Equalizer

Low Battery Indicator

Wind Noise Reduction Algorithm

NOAH / NOAH Link Compatible

Data Logging

®

OSPL90 CURVES

FREQUENCY RESPONSE CURVES

80

90

100

110

120

130

1000

Frequency in Hertz (Hz)

Out

put

in d

BS

PL

200 500 2000 5000 8000

407.339.2422 | [email protected]

Actual Size

SP_SOMBRA8S_3_20_rev- © PERSONA

BTE EARHOOK THIN TUBE

BTE EARHOOK THIN TUBE

Page 4: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

OSPL90 Maximum

OSPL90 @ 1600 Hz

HFAverage OSPL90

Peak Gain

HFA Full-On-Gain

Full-On-Gain @ 1600 Hz

Reference Test Gain

R.T.G @ 1600 Hz

Frequency Range (F1-F2)

THD at 500 Hz

800 Hz

1600 Hz

Equivalent Input Noise

Attack Time

Release Time

Battery Current Drain

Battery Life [13]*

Telecoil Sensitivity

ANSI S3.22-2003

2CC Coupler

137 dBSPL

N/A

129 dBSPL

70 dB

65 dB

N/A

52 dB

N/A

200 - 7100 Hz

< 3%

< 3%

< 3%

< 25 dB

10mS @ 2kHz*

25mS @ 2kHz*

1.25 mA

220 Hrs

115 dB SPL

IEC-118-0Ear Simulator

144 dBSPL

136 dBSPL

N/A

77 dB

N/A

72 dB

N/A

59 dB

N/A

< 3%

< 3%

< 3%

< 25 dB

10mS @ 2kHz*

25mS @ 2kHz*

1.25 mA

220 Hrs

123 dB SPL

20

30

40

50

60

70

1000

Frequency in Hertz (Hz)

Gai

n in

dB

SP

L

200 500 2000 5000 8000

0

10

20

30

40

50

60

70

80

90

100

110

120

125 250 500 1000 2000 4000 8000750 1500 3000 6000

Hea

ring

Leve

l In

Dec

ibel

s (d

B) l

lllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

Frequency in Hertz (Hz)

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

Open Ear

Sombra 8p series - FeaturesSpeech-Focus™ Null Tracking Directional Microphones

ALL-IN-ONE™ Adaptive Speech Enhancement

Feedback path eliminator

Auto-Adaptation Feedback Shield™

Adaptive telecoil switch

Hydrocoat moisture barrier

Environmental Classification Noise Reduction

128 Channels Noise Reduction

16 Band Frequency Programming Control

Memory Change (4) Indicator - Adjustable Level & Frequency

Multi-function Manual VC / Memory Change

Speech Mapping Compatible w/ Graphic Equalizer

Low Battery Indicator

Wind Noise Reduction Algorithm

NOAH / NOAH Link Compatible

Data Logging

®

OSPL90 CURVE

FREQUENCY RESPONSE CURVE

90

100

110

120

130

140

1000

Frequency in Hertz (Hz)

Out

put

in d

BS

PL

200 500 2000 5000 8000

407.339.2422 | [email protected]

Actual Size

SP_SOMBRA8P_3_20_rev- © PERSONA

Page 5: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

PERS�N.A: M t O I C A t..

oe :::J <

C/) -·

c,-

(1)

:::J (1) < (1) .....

0 0

� 0..

C/) 0

(0

0 0 0..

i

Page 6: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

OSPL90 MaximumOSPL90 @ 1600 HzHFAverage OSPL90

Peak GainHFA Full-On-Gain

Full-On-Gain @ 1600 HzReference Test Gain

R.T.G @ 1600 Hz

Frequency Range (F1-F2)

THD at 500 Hz800 Hz

1600 Hz

Equivalent Input NoiseTele-Coil Sensitivity

Attack TimeRelease Time

Battery Current DrainBattery Life [312]

ANSI S3.22-2003

2CC Coupler

Wide / Med / High

112 / 120 / 127 dBSPL N/A

107 / 117 / 123 dBSPL

49 / 59 / 66 dB42 / 52 / 62 dB

N/A30 / 40 / 46 dB

N/A

200 - 7500 Hz

< 3%< 3%< 3%

< 28 dB 86 / 96 / 100 dBSPL

6 mS @ 2kHz* 50 mS @ 2kHz*

.80 / .90 / 1.05 mA200 / 175 / 150Hrs

IEC-118-0Ear Simulator

Wide / Med / High

120 / 128 / 135 dBSPL 115 / 125 / 131 dBSPL

N/A

57 / 67 / 74 dBN/A

50 / 60 / 70 dBN/A

38 / 48 / 54 dB

N/A

N/AN/A

< 3%

< 28 dB 94 / 104 / 108 dBSPL

6 mS @ 2kHz* 50 mS @ 2kHz*

.80 / .90 / 1.05 mA200 / 175 / 150Hrs

FeaturesDigital / ProgrammableSpeech-Pro™ Auto Fit (Optional)Data LoggingSpeech Mapping Compatible w/ Graphic Equalizer ControlsHydroguardFocus Mic System™Feedback Shield™Tri-Mode Layered Noise ReductionTelephone CoilDynamic Speech Enhancement (DSE)12 Bands, 8 Channels4 Programmable MemoriesMemory Change Indicator w/ Adjustable Level and FrequencyLow Battery IndicatorPower on Delay w/ Adjustable LevelTinnitus Masker (Optional)

M E D I C A L

®

OSPL90 CURVES

FREQUENCY RESPONSE CURVES

*AGC not fully activated

80

90

100

110

120

130

1000

Frequency in Hertz (Hz)

Out

put i

n dB

SPL

200 500 2000 5000 8000

Wide

High

Med

10

20

30

40

50

1000

Frequency in Hertz (Hz)

Gai

n in

dB

200 500 2000 5000 8000

Wide

High

Med

800.789.6543 | [email protected]

20

30

40

50

60

70

80

90

100

110

125 250 500 1000 2000 4000 8000750 1500 3000 6000

Hea

ring

Leve

l In

Deci

bels

(dB)

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

Frequency in Hertz (Hz)

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

Wide

Med

High

Page 7: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

OSPL90 MaximumOSPL90 @ 1600 HzHFAverage OSPL90

Peak GainHFA Full-On-GainFull-On-Gain @ 1600 HzReference Test GainR.T.G @ 1600 Hz

Frequency Range (F1-F2)

THD at 500 Hz800 Hz1600 Hz

Equivalent Input NoiseTele-Coil Sensitivity

Attack TimeRelease Time

Battery Current DrainBattery Life [312]

ANSI S3.22-20032CC Coupler

Thin Tube / Earhook

120 / 127 dBSPL N/A108 / 119 dBSPL

55 / 70 dB50 / 62 dBN/A32 / 42 dBN/A

200-6500 / 7000 Hz

< 3%< 3%< 3%

< 27 / < 25 dB 91 / 102 dBSPL

10 mS @ 2kHz* 70 mS @ 2kHz*

1.02 / 1.12 mA149 / 135Hrs

IEC-118-0Ear Simulator

Thin Tube / Earhook

127 / 134 dBSPL 116 / 128 dBSPLN/A

62 / 78 dBN/A56 / 68 dBN/A38 / 48 dB

N/A

N/AN/A< 3%

< 27 / < 25 dB 99 / 110 dBSPL

10 mS @ 2kHz* 70 mS @ 2kHz*

1.02 / 1.12 mA149 / 135Hrs

Features

• Data Logging• 100% Digital Processing Device• 8 Channels• 12 Band Equalizer• Focus-Mic System™

• Tri-mode Layered Noise Reduction• Feedback Shield™

• Dynamic Speech Enhancement: (DSE)• Multi-function Digital Rocker: Volume/ Memory• 4 Memories w/ Indicators• Tone/Level Adjustments• Tele Solutions™

• Tinnitus Masker (Ole 2123)• Power on Delay with Adjustable levels• Hydroguard™

• Low Battery Warning w/indicator• 312Mini BTE High Impact Case• OTE Tube / BTE Earhook Compatible• Speech Pro™ Auto Fit (optional)• Speech Mapping Compatible w/Graphic Equalizer Controls

M E D I C A L

®

Frequency Response Curves

Fitting Range

Out

put i

n dB

SPL

Hea

ring

Leve

l in

dB

Frequency in Hertz (Hz)

Frequency in Hertz (Hz)

Frequency in Hertz (Hz)

Gai

n in

dB

*AGC not fully activated

OSPL90 Curves

800.789.6543 | [email protected]

2125 & 2123 Open Ear

90

100

110

120

130

1000200 500 2000 5000 80003000

10

20

30

40

50

1000200 500 2000 5000 80003000

20

30

40

50

60

70

80

90

100

110

125 250 500 1000 2000 4000 8000750 1500 3000 6000

Open Ear w/ ZipTip

Semi-Occluded w/ ZipTip

Occluded w/ ZipTip

Ear Hook

Page 8: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

OSPL90 MaximumOSPL90 @ 1600 HzHFAverage OSPL90

Peak GainHFA Full-On-Gain

Full-On-Gain @ 1600 HzReference Test Gain

R.T.G @ 1600 Hz

Frequency Range (F1-F2)

THD at 500 Hz800 Hz

1600 Hz

Equivalent Input Noise

Attack TimeRelease Time

Battery Current DrainBattery Life [10A]

ANSI S3.22-2003

2CC Coupler

107 dBSPLN/A

102 dBSPL

32 dB25 dBN/A

25 dB

200 - 7800 Hz

< 2%< 2%< 2%

< 28 dB

8mS @ 2kHz* 155mS @ 2kHz*

0.78 mA102 Hrs

IEC-118-0Ear Simulator

113 dBSPL105 dBSPL

N/A

37 dBN/A

30 dBN/A

30 dB

N/A

N/AN/A

< 2%

< 28 dB

8mS @ 2kHz* 155mS @ 2kHz*

0.78 mA102 Hrs

-10

0

10

20

30

40

1000

Frequency in Hertz (Hz)

Gai

n in

dB

200 500 2000 5000 8000

FeaturesDigital / ProgrammableOpen-Fit CIC 10A DeviceAirTouch™ Multi MemoryFeedback Shield™

Tri-Mode Layered Noise ReductionDynamic Speech Enhancement (DSE)12 Band, 8 Channel Processing4 Programmable MemoriesMemory Change IndicatorLow Battery IndicatorPower on Delay w/ Adjustable LevelWax Barrier / Wind ScreenTinnitus Masker (Option)SpeechPro (Option)Concha Lock (S, M, L Sizes)Low Group Delay - 5 ms

M E D I C A L

®

OSPL90 / FREQUENCY RESPONSE CURVES

AIDED GAIN CURVE

*AGC not fully activated

0

10

20

30

40

50

60

70

80

90

100

110

1000

Frequency in Hertz (Hz)

Out

put i

n dB

SPL

200 500 2000 5000 8000

Gain in dB

800.789.6543 | [email protected]

-10

0

10

20

30

40

50

60

70

80

125        250        500       1000       2000      4000      8000750       1500       3000      6000

Hearing Level In Decibels (dB)

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

Frequency in Hertz (Hz)

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

Open Ear

Semi-Occluded

Page 9: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

1D 32.-

Cl)

Q>

·u(I)

0

C

Q>

(I) ....J

0) C

·;::

(I)

Features

Digital / Programmable

Deep Fitting CIC 1 OA Device

AirTouch"' Multi Memory

4 Programmable Memories

Memory Change Indicator

Low Battery Indicator

Premier Feedback Shield"'

Tri-Mode Layered Noise Reduction

Dynamic Speech Enhancement

12 Band, 8 Channel Processing

Adjustable Power on Delay

Wax Barrier/ Wind Screen

Tinnitus Masker (Option)

Low Group Delay - 5 ms

SpeechPro (Option)

NOAH Compatible

Black Faceplate (Option)

Digital Shell in Beige Only

750 1500 3000 6000

0 125 250 500 1000 2000 4000 8000

10

20

30

40

50

60

70

80

90

---WIii .... .

, .... .�---

----------­........... ........... ..........

Frequency in Hertz (Hz)

PERS�N� M E D I C A L

800.789.6543 I [email protected]

OSPL90 Maximum

OSPL90@1600 Hz

HFAverage OSPL90

Peak Gain

HFA Full-On-Gain

Full-On-Gain@1600 Hz

Re ference Test Gain

R.T.G@1600 Hz

Frequency Range {F1-F2)

THD at 500 Hz

800 Hz

1600 Hz

Equivalent Input Noise

Attack Time

Re lease Time

Battery Cunent Drain

Battery Life [10A]

110

55 100

al ".£ 90

a 80

70

80

40

80

" 20

·.i C,

10

·10

ANSI ANSI IEC-118-0

$3.22-2003 $3.22-2003 Ear Simulator

1CC Coupler 2CC Coupler

120d8SPL 107d8SPL 109d8SPL

NIA NIA 104d8SPL

116d8SPL 103d8SPL NIA

42dB 32dB 29dB

37dB 27dB NIA

NIA NIA 32dB

39dB 26dB NIA

NIA NIA 31 dB

200-8000 Hz 200-8000 Hz NIA

<2% <2% NIA

<2% <2% NIA

<2% <2% <2%

<25dB <25dB <25dB

6mS@2kHz• 6mS@2kHz• 8mS@2kHz•

70mS@2kHz• 70mS@2kHz• 70mS@2kHz•

0.75mA 0.75mA 0.78mA

106 Hrs 106 Hrs 102 Hrs

•AGC not fully activated

OSPL90 CURVE

/

500 1000

Frequency in Hertz (Hz)

\

'

5000 8000

FREQUENCY RESPONSE CURVE

./ ----

200 500 1000

Frequency in Hertz (Hz)

\ '\

5000 8000

Page 10: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

OSPL90 Maximum

OSPL90 @ 1600 Hz

HFAverage OSPL90

Peak Gain

HFA Full-On-Gain

Full-On-Gain @ 1600 Hz

Reference Test Gain

R.T.G @ 1600 Hz

Frequency Range (F1-F2)

THD at 500 Hz

800 Hz

1600 Hz

Equivalent Input Noise

Attack Time

Release Time

Battery Current Drain

Battery Life [10A]

ANSI S3.22-2003

2CC Coupler

93 dBSPL

N/A

89 dBSPL

30 dB

25 dB

N/A

12 dB

N/A

200 - 7200 Hz

< 3%

< 3%

< 3%

< 28 dB

6mS @ 2kHz*

70mS @ 2kHz*

0.80 mA

100 Hrs

ANSI S3.22-2003

1CC Coupler

106 dBSPL

N/A

102 dBSPL

40 dB

34 dB

N/A

28 dB

N/A

200 - 7200 Hz

< 3%

< 3%

< 3%

< 28 dB

6mS @ 2kHz*

70mS @ 2kHz*

0.80 mA

100 Hrs

IEC-118-0Ear Simulator

100 dBSPL

90 dBSPL

N/A

31 dB

N/A

28 dB

N/A

28 dB

N/A

N/A

N/A

< 3%

< 28 dB

8mS @ 2kHz*

70mS @ 2kHz*

0.80 mA

100 Hrs

1000

Frequency in Hertz (Hz)

200 500 2000 5000 8000

Gain in dB

-10

0

10

20

30

40

Features

Digital Stock CIC 10A Device

SSVC Gain Control

AirTouchTM Multi Memory

Premier Feedback Shield TM

Tri-Mode Layered Noise Reduction

Dynamic Speech Enhancement

12 Band, 8 Channel Processing

4 Programmable Memories

Memory Change Indicator

Low Battery Indicator

Power on Delay

Wax Barrier / Wind Screen

Beige or Black Shell

Dome Tips (SVt only)

0

10

20

30

40

50

60

70

80

90

125        250        500       1000       2000      4000      8000750       1500       3000      6000

Hearing Level In Decibels (dB)

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

Frequency in Hertz (Hz)

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

M E D I C A L

®

OSPL90 CURVE

FREQUENCY RESPONSE CURVE

*AGC not fully activated

50 

60 

70 

80 

 90 

100 

1000

Frequency in Hertz (Hz)

Output in dBSPL

200 500 2000 5000 8000

800.789.6543 | [email protected]

SV &SVt

Page 11: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

OSPL90 MaximumOSPL90 @ 1600 HzHFAverage OSPL90

Peak GainHFA Full-On-Gain

Full-On-Gain @ 1600 HzReference Test Gain

R.T.G @ 1600 Hz

Frequency Range (F1-F2)

THD at 500 Hz800 Hz

1600 Hz

Equivalent Input Noise

Attack TimeRelease Time

Battery Current DrainBattery Life [10A]

ANSI S3.22-2003

2CC CouplerStandard/Power

115/120 dBSPLN/A

110/115 dBSPL

40/48 dB35/43 dB

N/A33/38 dB

N/A

200 - 8000 Hz

< 3%< 3%< 3%

< 26 dB SPL

6mS @ 2kHz* 30mS @ 2kHz*

.95/1.2 mA84/65 Hrs

IEC-118-0Ear SimulatorStandard/Power

123/128 dBSPL118/123 dBSPL

N/A

48/56 dBN/A

43/51 dBN/A

41/46 dB

N/A

N/AN/A

< 3%

< 26 dB SPL

6mS @ 2kHz* 30mS @ 2kHz*

.95/1.2 mA84/65 Hrs

Features• Toggle VC/MM Switch• Feedback Shield• Data logging• Tri-Mode Layered Noise Reduction• Dynamic Speech Enhancement (DSE)• 12 Band, 8 Channel Processing• 4 Programmable Memories• Memory Change Indicator

w/Adjustable Level & Frequency• Low Battery Indicator• Power on delay w/Adjustable Level• Wax Barrier/Wind Screen• Speech Mapping Compatible w

Graphic Equalizer Controls• NOAH Compatible• 3D LazerVeyor Digital Shell Process

Options:• Digital Volume Control• SSVC with Enhanced Taper Control• AirTouch Multi Memory• Multi Memory Push Button• Speech Pro Auto Fit• Tinnitus Masker• Power Matrix

M E D I C A L

®

OSPL90 CURVES

*AGC not fully activated

800.789.6543 | [email protected]

-10

0

10

20

30

40

50

60

70

80

90

100

110

125 250 500 1000 2000 4000 8000750 1500 3000 6000

Hea

ring

Leve

l In

Dec

ibel

s (d

B)

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

Frequency in Hertz (Hz)

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

CIC

FREQUENCY RESPONSE CURVE60 dB SPL input at RTG

70

80

90

100

110

120

1000

Frequency in Hertz (Hz)

Out

put i

n dB

SPL

200 500 2000 5000 8000

Power

Standard

0

10

20

30

40

50

1000

Frequency in Hertz (Hz)

Gai

n in

dB

200 500 2000 5000 8000

Power

Standard

Page 12: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

Features• Toggle VC/MM Switch• Feedback Shield• Data logging• Tri-Mode Layered Noise Reduction• Dynamic Speech Enhancement (DSE)• 12 Band, 8 Channel Processing• 4 Programmable Memories• Memory Change Indicator w/Adjust- able Level & Frequency• Low Battery Indicator• Power on delay w/Adjustable Level• Wax Barrier/Wind Screen• Speech Mapping Compatible w/

Graphic Equalizer Controls• NOAH Compatible• 3D LazerVeyor Digital Shell Process

Options:• Digital Volume Control• Analog VC or SSVC with Enhanced Taper Control• AirTouch Multi Memory• Multi Memory Push Button• Speech Pro Auto Fit• Tinnitus Masker• Power Matrix

M E D I C A L

®

OSPL90 CURVES

*AGC not fully activated

800.789.6543 | [email protected]

-10

0

10

20

30

40

50

60

70

80

90

100

110

125 250 500 1000 2000 4000 8000750 1500 3000 6000

Hea

ring

Leve

l In

Dec

ibel

s (d

B)

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

Frequency in Hertz (Hz)

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

OSPL90 MaximumOSPL90 @ 1600 HzHFAverage OSPL90

Peak GainHFA Full-On-Gain

Full-On-Gain @ 1600 HzReference Test Gain

R.T.G @ 1600 Hz

Frequency Range (F1-F2)

THD at 500 Hz800 Hz

1600 Hz

Equivalent Input Noise

Attack TimeRelease Time

Battery Current DrainBattery Life [10A]

ANSI S3.22-2003

2CC CouplerStandard/Power

115/120 dB SPLN/A

110/115 dB SPL

48/56 dB35/43 dB

N/A33/38 dB

N/A

200 - 8000 Hz

< 3%< 3%< 3%

< 26 dB SPL

6mS @ 2kHz* 30mS @ 2kHz*

.95/1.2 mA84/65 Hrs

IEC-118-0Ear SimulatorStandard/Power

123/128 dB SPL118/123 dB SPL

N/A

40/48 dBN/A

43/51 dBN/A

41/46 dB

N/A

N/AN/A

< 3%

< 26 dB SPL

6mS @ 2kHz* 30mS @ 2kHz*

.95/1.2 mA84/65 Hrs

Mini

FREQUENCY RESPONSE CURVE60 dB SPL input at RTG

70

80

90

100

110

120

1000

Frequency in Hertz (Hz)

Out

put i

n dB

SPL

200 500 2000 5000 8000

Power

Standard

0

10

20

30

40

50

1000

Frequency in Hertz (Hz)

Gai

n in

dB

200 500 2000 5000 8000

Power

Standard

Page 13: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

Features• Toggle VC/MM Switch• Feedback Shield• Data logging• Tri-Mode Layered Noise Reduction• Dynamic Speech Enhancement (DSE)• 12 Band, 8 Channel Processing• 4 Programmable Memories• Memory Change Indicator w/Adjust- able Level & Frequency• Low Battery Indicator• Power on delay w/Adjustable Level• Wax Barrier/Wind Screen• Speech Mapping Compatible w/

Graphic Equalizer Controls• NOAH Compatible• 3D LazerVeyor Digital Shell Process

Options:• Digital Volume Control• Tele-Solutions• Analog VC or SSVC with Enhanced Taper Control• AirTouch Multi Memory• Multi Memory Push Button• Speech Pro Auto Fit• Tinnitus Masker• Power Matrix

M E D I C A L

®

OSPL90 CURVES*AGC not fully activated

800.789.6543 | [email protected]

-10

0

10

20

30

40

50

60

70

80

90

100

110

125 250 500 1000 2000 4000 8000750 1500 3000 6000

Hea

ring

Leve

l In

Dec

ibel

s (d

B)

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

Frequency in Hertz (Hz)

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

70

80

90

100

110

120

1000

Frequency in Hertz (Hz)

Out

put i

n dB

SPL

200 500 2000 5000 8000

Power

Standard

OSPL90 MaximumOSPL90 @ 1600 HzHFAverage OSPL90

Peak GainHFA Full-On-Gain

Full-On-Gain @ 1600 HzReference Test Gain

R.T.G @ 1600 Hz

Frequency Range (F1-F2)

THD at 500 Hz800 Hz

1600 Hz

Equivalent Input Noise

Attack TimeRelease Time

Telephone Coil Sensitivity(SPLITS)

Battery Current DrainBattery Life [312]

ANSI S3.22-2003

2CC CouplerStandard/Power

115/120 dBSPLN/A

110/115 dBSPL

50/58 dB45/53 dB

N/A33/38 dB

N/A

200 - 8000 Hz

< 3%< 3%< 3%

< 26 dB SPL

6mS @ 2kHz* 30mS @ 2kHz*

93/98 dB SPL

.95/1.2 mA160/126 Hrs

IEC-118-0Ear SimulatorStandard/Power

123/128 dBSPL118/123 dBSPL

N/A

58/66 dBN/A

43/51 dBN/A

41/46 dB

N/A

N/AN/A

< 3%

< 26 dB SPL

6mS @ 2kHz* 30mS @ 2kHz*

100/105 dB SPL

.95/1.2 mA160/126 Hrs

Canal

FREQUENCY RESPONSE CURVE60 dB SPL input at RTG

0

10

20

30

40

50

1000

Frequency in Hertz (Hz)

Gai

n in

dB

200 500 2000 5000 8000

Power

Standard

Page 14: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

Features• Toggle VC/MM Switch• Feedback Shield• Data logging• Tri-Mode Layered Noise Reduction• Dynamic Speech Enhancement (DSE)• 12 Band, 8 Channel Processing• 4 Programmable Memories• Memory Change Indicator w/Adjust- able Level & Frequency• Low Battery Indicator• Power on delay w/Adjustable Level• Wax Barrier/Wind Screen• Speech Mapping Compatible w/ Graphic Equalizer Controls• NOAH Compatible• 3D LazerVeyor Digital Shell Process

Options:• Multi Memory Push Button• AirTouch Multi Memory• Speech Pro Auto Fit• Tele-Solutions• Tinnitus Masker• Power Matrix• Digital Volume Control• Analog VC or SSVC with Enhanced Taper Control• Focus Mic System

M E D I C A L

®

OSPL90 CURVES

800.789.6543 | [email protected]

*AGC not fully activated

OSPL90 MaximumOSPL90 @ 1600 HzHFAverage OSPL90

Peak GainHFA Full-On-Gain

Full-On-Gain @ 1600 HzReference Test Gain

R.T.G @ 1600 Hz

Frequency Range (F1-F2)

THD at 500 Hz800 Hz

1600 Hz

Equivalent Input Noise

Attack TimeRelease Time

Telephone Coil Sensitivity(SPLITS)

Battery Current DrainBattery Life [312]

ANSI S3.22-2003

2CC CouplerStandard/Power

115/120 dBSPLN/A

110/115 dBSPL

50/58 dB52/60 dB

N/A33/38 dB

N/A

200 - 8000 Hz

< 3%< 3%< 3%

< 26 dB SPL

6mS @ 2kHz* 30mS @ 2kHz*

93/98 dB SPL

.95/1.2 mA160/126 Hrs

IEC-118-0Ear SimulatorStandard/Power

123/128 dBSPL118/123 dBSPL

N/A

58/66 dBN/A

43/51 dBN/A

41/46 dB

N/A

N/AN/A

< 3%

< 26 dB SPL

6mS @ 2kHz* 30mS @ 2kHz*

100/105 dB SPL

.95/1.2 mA160/126 Hrs

Half Shell

FREQUENCY RESPONSE CURVE60 dB SPL input at RTG

70

80

90

100

110

120

1000

Frequency in Hertz (Hz)

Out

put i

n dB

SPL

200 500 2000 5000 8000

Power

Standard

0

10

20

30

40

50

1000

Frequency in Hertz (Hz)

Gai

n in

dB

200 500 2000 5000 8000

Power

Standard

-10

0

10

20

30

40

50

60

70

80

90

100

110

125 250 500 1000 2000 4000 8000750 1500 3000 6000

Hea

ring

Leve

l In

Dec

ibel

s (d

B)

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

Frequency in Hertz (Hz)

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

Page 15: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

Features• Toggle VC/MM Switch• Feedback Shield• Data logging• Tri-Mode Layered Noise Reduction• Dynamic Speech Enhancement (DSE)• 12 Band, 8 Channel Processing• 4 Programmable Memories• Memory Change Indicator w/Adjust- able Level & Frequency• Low Battery Indicator• Power on delay w/Adjustable Level• Wax Barrier/Wind Screen• Speech Mapping Compatible w/ Graphic Equalizer Controls• NOAH Compatible• 3D LazerVeyor Digital Shell Process

Options:• Multi Memory Push Button• Speech Pro Auto Fit • Tele-Solutions • Tinnitus Masker • Power Matrix• Digital Volume Control• Analog VC or SSVC with Enhanced Taper Control• Focus Mic System• Rechargeable

M E D I C A L

®

OSPL90 CURVES

FREQUENCY RESPONSE CURVE60 dB SPL input at RTG

800.789.6543 | [email protected]

Rechargeable 8 hour Charge, 16 hour use (standard matrix only, 120/55)

*AGC not fully activated

-10

0

10

20

30

40

50

60

70

80

90

100

110

125 250 500 1000 2000 4000 8000750 1500 3000 6000

Hea

ring

Leve

l In

Dec

ibel

s (d

B)

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

Frequency in Hertz (Hz)

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

ANSI S3.22-2003

2CC CouplerStandard/Power

120/130 dB SPLN/A

115/124 dB SPL

55/65 dB50/60 dB

N/A38/47 dB

N/A

200 - 8000 Hz

< 3%< 3%< 3%

< 26 dB SPL

6mS @ 2kHz* 30mS @ 2kHz*

98/107 dB SPL

.95/1.2 mA284/180 Hrs

IEC-118-0Ear SimulatorStandard/Power

128/138 dB SPL123/132 dB SPL

N/A

63/72 dBN/A

58/68 dBN/A

46/55 dB

N/A

N/AN/A

< 3%

< 26 dB SPL

6mS @ 2kHz* 30mS @ 2kHz*

106/115 dB SPL

.95/1.2 mA284/180 Hrs

0

90

100

110

120

130

1000

Frequency in Hertz (Hz)

Out

put i

n dB

SPL

200 500 2000 5000 8000

Power

Standard

0

20

30

40

50

60

1000

Frequency in Hertz (Hz)

Gai

n in

dB

200 500 2000 5000 8000

Power

Standard

Full Shell OSPL90 MaximumOSPL90 @ 1600 HzHFAverage OSPL90

Peak GainHFA Full-On-Gain

Full-On-Gain @ 1600 HzReference Test Gain

R.T.G @ 1600 Hz

Frequency Range (F1-F2)

THD at 500 Hz800 Hz

1600 Hz

Equivalent Input Noise

Attack TimeRelease Time

Telephone Coil Sensitivity(SPLITS)

Battery Current DrainBattery Life [13]

EVõK THE POSSIBILITIES

The best way to predict the future is to invent it! Persona has revo-lutionized the hearing industry by introducing EVõK and SpeechPro. EVõK employs a wide assortment of advanced signal processing strategies and automatic/adaptive features optimizing the listening experience. Then, as if creating the most advanced hearing instru-ment wasn’t enough, we took it up a notch!

Introducing SpeechPro, the world’s first fitting system that automati-cally programs the hearing instrument using live input. SpeechPro coupled with the EVõK product line delivers the most accurate fitting in the least amount of time, guaranteed! For the first time ever, fit and verify your instruments simultaneously. Spend less time manipulating software and more time with happy patients.

Life is all about change and how we adapt to it. Keeping pace with modern living means the need to a flexible hearing system that can accommodate those changes. Whether the need is for a discrete over the ear model, a powerful behind the ear, or a custom mini canal, EVoK has what you need to fit the toughest patient.

GUARANTEE OF QUALITY

A belief that in order to succeed, you must have a certain passion and desire to give your every endeavor your very best. Our ISO 9001:2000 World Wide Quality Certification and European Safety Certification (CE Mark), does attest that Persona Medical has built a reputation on these principles. For five decades, Persona Medical has forged this very commitment to excellence into every hearing instrument we design. A rare combination of state of the art technology and custom craftsmanship brings you the best instruments available today.

PE

RS

N

AM

ED

IC

AL

®

170 N. Cypress WayCasselberry, FL 32707

(407) 339.2422personamedical.com

TF/EV/3 © 15 PERSONA

As a premium line, EVõK takes into account all unique hearing needs. Automatic features and multiple listening programs allow patients to enjoy family, friends, telephone, the television, and even demanding environments like restaurants. With multiple features like data logging, a premier feedback canceller and an amazing noise reduction algorithm, EVõK lets people savor life and join in the fun.

Page 16: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

EVõK THE POSSIBILITIES

The best way to predict the future is to invent it! Persona has revo-lutionized the hearing industry by introducing EVõK and SpeechPro. EVõK employs a wide assortment of advanced signal processing strategies and automatic/adaptive features optimizing the listening experience. Then, as if creating the most advanced hearing instru-ment wasn’t enough, we took it up a notch!

Introducing SpeechPro, the world’s first fitting system that automati-cally programs the hearing instrument using live input. SpeechPro coupled with the EVõK product line delivers the most accurate fitting in the least amount of time, guaranteed! For the first time ever, fit and verify your instruments simultaneously. Spend less time manipulating software and more time with happy patients.

Life is all about change and how we adapt to it. Keeping pace with modern living means the need to a flexible hearing system that can accommodate those changes. Whether the need is for a discrete over the ear model, a powerful behind the ear, or a custom mini canal, EVoK has what you need to fit the toughest patient.

GUARANTEE OF QUALITY

A belief that in order to succeed, you must have a certain passion and desire to give your every endeavor your very best. Our ISO 9001:2000 World Wide Quality Certification and European Safety Certification (CE Mark), does attest that Persona Medical has built a reputation on these principles. For five decades, Persona Medical has forged this very commitment to excellence into every hearing instrument we design. A rare combination of state of the art technology and custom craftsmanship brings you the best instruments available today.

PE

RS

N

AM

ED

IC

AL

®

170 N. Cypress WayCasselberry, FL 32707

(407) 339.2422personamedical.com

TF/EV/3 © 15 PERSONA

As a premium line, EVõK takes into account all unique hearing needs. Automatic features and multiple listening programs allow patients to enjoy family, friends, telephone, the television, and even demanding environments like restaurants. With multiple features like data logging, a premier feedback canceller and an amazing noise reduction algorithm, EVõK lets people savor life and join in the fun.

Page 17: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

OSPL90 Maximum

OSPL90 @ 1600 Hz

Peak Gain

Full-On-Gain @ 1600 Hz

R.T.G @ 1600 Hz

Frequency Range: f1-f2

THD at 500 Hz

800 Hz

1600 Hz

Eq. Input Noise Level

Attack Time

Release Time

Battery Current Drain

Battery Life [312]

128/133 dBSPL

118/125 dBSPL

50/60 dB

43/52 dB

41/48 dB

200-8000 Hz

< 3%

< 3%

< 3%

< 26 dBSPL

6 mS @ 2kHz

30 mS @ 2kHz

0.95 mA

160 hrs

OSPL90 Maximum

HF Average OSPL90

Peak Gain

HFA Full-On-Gain

Reference Test Grain

Frequency Range: f1-f2

THD at 500 Hz

800 Hz

1600 Hz

Eq. Input Noise Level

Attack Time

Release Time

Battery Current Drain

Battery Life [312]

120/125 dBSPL

110/117 dBSPL

42/52 dB

35/44 dB

33/40 dB

200-8000 Hz

< 3%

< 3%

< 3%

< 26 dBSPL

6 mS @ 2kHz

30 mS @ 2kHz

0.95 mA

160 hrs

uu Speech-ProTM Auto Fit (Optional)

uu Data Logging

uu Speech Mapping Compatible w/ Graphic Equalizer Controls

uu Focus-Mic SystemTM

uu Feedback ShieldTM

uu Hydroguard

uu Tri-Mode Layered Noise Reduction

uu Dynamic Speech Enhancement (DSE)

uu 12 Bands, 8 Channels

uu 4 Programmable Memories

uu Memory Change Indicator w/ Adjustable Level and Frequency

uu Low Battery Indicator

uu Power on Delay w/ Adjustable Level

uu NOAH Compatible

*Test Settings Provided Upon Request

OU

TPU

T IN

dB

SP

L

FREQUENCY IN Hz

OSPL 90 CURVE

250 500 1000 2000 4000 8000

OTE Thin Tube BTE Ear Hook

2cc COUPLER CURVES

Ear Simulator [IEC-118-0]* Thin Tube /Ear Hook 2cc Coupler [ANSI S3.22-1996]* Thin Tube / Ear Hook

HEA

RIN

G L

EVEL

S IN

DEC

IBEL

S (d

B)

FITTING RANGE 0

20

40

60

80

100

125 250 500 1000 2000 4000 8000

FREQUENCY IN Hz

SEMI - OCCLUDED

OCCLUDED

OPEN EAR

EARHOOK

GA

IN IN

dB

FREQUENCY IN Hz

60

50

40

30

20250 500 1000 2000 4000 8000

FREQUENCY RESPONSE CURVES

130

120

110

100

90

927 SPECIFICATIONS

OTE / BTE (On The Ear/ Behind The Ear)

Reference Test Gain @ 50 dB

Page 18: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

Ear Simulator [IEC-118-0]* 2cc Coupler [ANSI S3.22-1996]*

OSPL90 Maximum

OSPL90 @ 1600 Hz

Peak Gain

Full-On-Gain @ 1600 Hz

R.T.G @ 1600 Hz

Frequency Range: f1-f2

THD at 500 Hz

800 Hz

1600 Hz

Eq. Input Noise Level

Attack / Release Time

Tele-Coil Sensitivity

Battery Current Drain

Battery Life [13]

141 dBSPL

133 dBSPL

78 dB

71 dB

56 dB

200-7000 Hz

< 3%

< 3%

< 3%

< 26 dBSPL

6 / 30 mS @ 2kHz

115 dBSPL

0.95 mA

284 hrs

OSPL90 Maximum

HF Average OSPL90

Peak Gain

HFA Full-On-Gain

Reference Test Grain

Frequency Range: f1-f2

THD at 500 Hz

800 Hz

1600 Hz

Eq. Input Noise Level

Attack / Release Time

Tele-Coil Sensitivity

Battery Current Drain

Battery Life [13]

133 dBSPL

125 dBSPL

70 dB

63 dB

48 dB

200-7000 Hz

< 3%

< 3%

< 3%

< 26 dBSPL

6 / 30 mS @ 2kHz

108 dBSPL

0.95 mA

284 hrs

uu Speech-ProTM Auto Fit (Optional) uu Data Logginguu Focus-Mic SystemTM

uu Feedback ShieldTM

uu TelesolutionsTM (Optional)uu Tri-Mode Layered Noise Reductionuu Dynamic Speech Enhancement (DSE) uu VC w/ Enhanced Taper Controluu 12 Bands, 8 Channelsuu 4 Programmable Memoriesuu Memory Change Indicator w/ Adjustable Level and Frequencyuu Low Battery Indicatoruu Power on Delay w/ Adjustable Level uu Speech Mapping Compatible w/ Graphic Equalizer Controlsuu NOAH Compatible uu Direct Audio Input (DAI)uu Wind Screen

*Test Settings Provided Upon Request

937 SPECIFICATIONS 2cc COUPLER CURVES

OU

TPU

T IN

dB

SP

L

FREQUENCY IN Hz

OSPL 90 CURVE140

130

120

110

100250 500 1000 2000 4000 8000

GA

IN IN

dB

FREQUENCY IN Hz

60

50

40

30

20250 500 1000 2000 4000 8000

BTE (Behind The Ear)H

EAR

ING

LEV

ELS

IN D

ECIB

ELS

(dB

)

FITTING RANGE 20

40

60

80

100

120

125 250 500 1000 2000 4000 8000

FREQUENCY IN Hz

FREQUENCY RESPONSE CURVE

Reference Test Gain @ 50 dB

Page 19: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

OSPL90 Maximum

OSPL90 @ 1600 Hz

Peak Gain

Full-On-Gain @ 1600 Hz

R.T.G @ 1600 Hz

Frequency Range: f1-f2

THD at 500 Hz

800 Hz

1600 Hz

Eq. Input Noise Level

Attack Time

Release Time

Battery Current Drain

Battery Life [10A]

OSPL90 Maximum

HF Average OSPL90

Peak Gain

HFA Full-On-Gain

Reference Test Grain

Frequency Range: f1-f2

THD at 500 Hz

800 Hz

1600 Hz

Eq. Input Noise Level

Attack Time

Release Time

Battery Current Drain

Battery Life [10A]

uu Speech-ProTM Auto Fit (Optional)uu Data Logginguu Feedback ShieldTM

uu Tri-Mode Layered Noise Reductionuu Dynamic Speech Enhancement (DSE) uu Power Matrix (Optional)uu Digital Volume Control (Mini Canal Only)uu SSVC w/ Enhanced Taper Control (Optional)uu 12 Bands, 8 Bandsuu 4 Programmable Memoriesuu Memory Change Indicator w/ Adjustable Level and Frequencyuu Low Battery Indicatoruu Power on Delay w/ Adjustable Level uu Speech Mapping Compatible w/ Graphic Equalizer Controlsuu NOAH Compatibleuu 3D LazerVeyor Digital Shell Process

*Test Settings Provided Upon Request

900 SPECIFICATIONS

123/ 128 dBSPL

118/ 123 dBSPL

48/ 56 dB

43/51 dB

41/46 dB

200-8000 Hz

< 3%

< 3%

< 3%

< 26 dBSPL

6 mS @ 2kHz

30 mS @ 2kHz

0.95/ 1.2mA

84/ 66 hrs

115/ 120 dBSPL

110/ 115 dBSPL

40/48 dB

35/ 43 dB

33/ 38 dB

200-8000 Hz

< 3%

< 3%

< 3%

< 26 dBSPL

6 mS @ 2kHz

30 mS @ 2kHz

0.95/ 1.2 mA

84/ 66 hrs

MINI CANAL AND CIC

GA

IN IN

dB

FREQUENCY IN Hz

50

40

30

20

10250 500 1000 2000 4000 8000

FREQUENCY RESPONSE CURVES

OU

TPU

T IN

dB

SP

L

FREQUENCY IN Hz

OSPL 90 CURVE130

120

110

100

90250 500 1000 2000 4000 8000

HEA

RIN

G L

EVEL

S IN

DEC

IBEL

S (d

B)

FITTING RANGE 0

20

40

60

80

100

125 250 500 1000 2000 4000 8000

FREQUENCY IN Hz

Standard Power

2cc COUPLER CURVES

Ear Simulator [IEC-118-0]* Standard / Power 2cc Coupler [ANSI S3.22-1996]* Standard / Power

Reference Test Gain @ 50 dB

Page 20: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

Ear Simulator [IEC-118-0]* Standard/ Power 2cc Coupler [ANSI S3.22-1996]* Standard/ Power

OSPL90 Maximum

OSPL90 @ 1600 Hz

Peak Gain

Full-On-Gain @ 1600 Hz

R.T.G @ 1600 Hz

Frequency Range: f1-f2

THD at 500 Hz

800 Hz

1600 Hz

Eq. Input Noise Level

Attack / Release Time

Tele-Coil Sensitivity

Battery Current Drain

Battery Life [312A]

123/ 128 dBSPL

118/ 123 dBSPL

58/ 66 dB

52/ 60 dB

41/ 46 dB

200-8000 Hz

< 3%

< 3%

< 3%

< 26 dBSPL

6 / 30 mS @ 2kHz

100/ 105 dBSPL

0.95/ 1.2 mA

160/ 126 hrs

OSPL90 Maximum

HF Average OSPL90

Peak Gain

HFA Full-On-Gain

Reference Test Grain

Frequency Range: f1-f2

THD at 500 Hz

800 Hz

1600 Hz

Eq. Input Noise Level

Attack / Release Time

Tele-Coil Sensitivity

Battery Current Drain

Battery Life [312A]

115/ 120 dBSPL

110/ 115dBSPL

50/ 58 dB

45/ 53 dB

33/ 38 dB

200-8000 Hz

< 3%

< 3%

< 3%

< 26 dBSPL

6 / 30 mS @ 2kHz

93/ 98 dBSPL

0.95/ 1.2 mA

160/ 126 hrs

uu Speech-ProTM Auto Fit (Optional)uu Data Logginguu Focus-Mic SystemTM (Optional)uu Feedback ShieldTM

uu Power Matrix (Optional) uu TelesolutionsTM (Optional)uu Tri-Mode Layered Noise Reductionuu Dynamic Speech Enhancement (DSE) uu Digital Volume Controluu VC w/ Enhanced Taper Control (Optional)uu 12 Bands, 8 Channelsuu 4 Programmable Memoriesuu Memory Change Indicator w/ Adjustable Level and Frequencyuu Low Battery Indicatoruu Power on Delay w/ Adjustable Level uu Speech Mapping Compatible w/ Graphic Equalizer Controlsuu NOAH Compatibleuu 3D LazerVeyor Digital Shell Process

*Test Settings Provided Upon Request

900 SPECIFICATIONS

HALF SHELL AND CANAL

OU

TPU

T IN

dB

SP

L

FREQUENCY IN Hz

OSPL 90 CURVE130

120

110

100

90250 500 1000 2000 4000 8000

GA

IN IN

dB

FREQUENCY IN Hz

50

40

30

20

10250 500 1000 2000 4000 8000

FREQUENCY RESPONSE CURVES

HEA

RIN

G L

EVEL

S IN

DEC

IBEL

S (d

B)

FITTING RANGE 0

20

40

60

80

100

125 250 500 1000 2000 4000 8000

FREQUENCY IN Hz

Standard Power

2cc COUPLER CURVES

Reference Test Gain @ 50 dB

Page 21: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

Ear Simulator [IEC-118-0]* Standard / Power 2cc Coupler [ANSI S3.22-1996]* Standard / Power

OSPL90 Maximum

OSPL90 @ 1600 Hz

Peak Gain

Full-On-Gain @ 1600 Hz

R.T.G @ 1600 Hz

Frequency Range: f1-f2

THD at 500 Hz

800 Hz

1600 Hz

Eq. Input Noise Level

Attack / Release Time

Tele-Coil Sensitivity

Battery Current Drain

Battery Life [13]

OSPL90 Maximum

HF Average OSPL90

Peak Gain

HFA Full-On-Gain

Reference Test Grain

Frequency Range: f1-f2

THD at 500 Hz

800 Hz

1600 Hz

Eq. Input Noise Level

Attack / Release Time

Tele-Coil Sensitivity

Battery Current Drain

Battery Life [13]

uu Speech-ProTM Auto Fit (Optional)uu Data Logginguu Focus-Mic SystemTM (Optional) uu TelesolutionsTM (Optional)uu Power Matrix (Optional) and Rechargeable (Optional)uu Feedback ShieldTM

uu Digital Volume Controluu Tri-Mode Layered Noise Reductionuu Dynamic Speech Enhancement (DSE) uu VC w/ Enhanced Taper Control (Optional)uu 12 Bands, 8 Channelsuu 4 Programmable Memoriesuu Memory Change Indicator w/ Adjustable Level and Frequencyuu Low Battery Indicatoruu Power on Delay w/ Adjustable Level uu Speech Mapping Compatible w/ Graphic Equalizer Controlsuu NOAH Compatibleuu 3D LazerVeyor Digital Shell Process

*Test Settings Provided Upon Request

FULL SHELL

GA

IN IN

dB

FREQUENCY IN Hz

60

50

40

30

20250 500 1000 2000 4000 8000

FREQUENCY RESPONSE CURVES

OU

TPU

T IN

dB

SP

L

FREQUENCY IN Hz

OSPL 90 CURVE130

120

110

100

90250 500 1000 2000 4000 8000

128/ 138 dBSPL

123/ 132 dBSPL

63/ 72 dB

58/ 68 dB

46/ 55 dB

200-8000 Hz

< 3%

< 3%

< 3%

< 26 dBSPL

6 / 30 mS @ 2kHz

106/ 115 dBSPL

0.95/ 1.5mA

284/ 180 hrs

120/ 130 dBSPL

115/ 124dBSPL

55/65 dB

50/ 60 dB

38/ 47 dB

200-8000 Hz

< 3%

< 3%

< 3%

< 26 dBSPL

6 / 30 mS @ 2kHz

98/ 107 dBSPL

0.95/ 1.5 mA

284/ 180 hrs

HEA

RIN

G L

EVEL

S IN

DEC

IBEL

S (d

B)

FITTING RANGE0

20

40

60

80

100

125 250 500 1000 2000 4000 8000

FREQUENCY IN Hz

Standard Power

2cc COUPLER CURVES900 SPECIFICATIONS

Reference Test Gain @ 50 dB

Page 22: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

Features

• Digital/Programmable• AdaptiveDirectionalMicrophones• Telecoil• Hydrocoat• DigitalVolumeControl• MultiMemoryPushButton• Volume/MemoryRetentionVMRTMafter

PowerCycle• FeedbackShield™• Tri-ModeLayeredNoiseReduction• DynamicSpeechEnhancement(DSE)• 12Bands,8Channels• 4ProgrammableMemories• MemoryChangeIndicatorw/AdjLevel/Freq• LowBatteryIndicator• VoicePrompts• NOAH/NOAHLinkCompatible• Speech-Pro™AutoFit• Datalogging

®

800.789.6543|[email protected]/2016

122 / 129 dBSPL

112 / 123 dBSPL

N/A

57 / 68 dB

52 / 60 dB

N/A

36 / 47 dB

200-6300 Hz

< 3%

< 3%

< 3%

< 25 dBSPL

95 / 107 dBSPL

10 mS @ 2kHz

70 mS @ 2kHz

0.95 mA

165 hrs

129 / 136 dBSPL

N/A

118 / 130 dBSPL

63 / 76 dB

N/A

58 / 70 dB

43 / 53 dB

N/A

< 3%

< 3%

< 3%

< 25 dBSPL

104 / 115 dBSPL

10 mS @ 2kHz

70 mS @ 2kHz

1.00 mA

160 hrs

OSPL 90 CURVE

800 Series OSPL90 Maximum

OSPL90 @ 1600 Hz

HFAverage OSPL90

Peak Gain

HFA Full-On-Gain

Full-On-Gain @ 1600 Hz

Reference Test Gain

R.T.G @ 1600 Hz

Frequency Range (F1-F2)

THD at 500 Hz

800 Hz

1600 Hz

Equivalent Input Noise

Tele-Coil Sensitivity

Attack Time

Release Time

Battery Current Drain

Battery Life [312]

IEC-118-0Ear Simulator

Thin Tube / Earhook

ANSI S3.22-20032CC Coupler

Thin Tube / Earhook

*AGCnotfullyactivated

Fitting Range

Hea

ring

Leve

l in

dB

Frequency in Hertz (Hz)

20

30

40

50

60

70

80

90

100

110

125 250 500 1000 2000 4000 8000750 1500 3000 6000

Open Ear w/ ZipTip

Semi-Occluded w/ ZipTip

Occluded w/ ZipTip

Ear Hook

THIN TUBE BTE EARHOOK

Frequency Response Curves

Out

put i

n dB

SPL

Frequency in Hertz (Hz)

Frequency in Hertz (Hz)

Gai

n in

dB

OSPL90 Curves

20

30

40

50

60

1000200 500 2000 5000 80003000

90

100

110

120

130

1000200 500 2000 5000 80003000

Actual Size

Page 23: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

Features

• Digital/Programmable• AdaptiveDirectionalMicrophones• Hydrocoat• AssignablePushButton(Multi-Memory,Gain,

orMM+Gain)• FeedbackShield™• Tri-ModeLayeredNoiseReduction• DynamicSpeechEnhancement(DSE)• 12Bands,8Channels• 4ProgrammableMemories• MemoryChangeIndicatorw/AdjLevel/Freq• Volume/MemoryRetentionVMRTMafter

PowerCycle• LowBatteryIndicator• VoicePrompts• NOAH/NOAHLinkCompatible• Speech-Pro™AutoFit(Optional)• SpeechMappingCompatiblew/Graphic

EqualizerControls• Datalogging

®

800.789.6543|[email protected]/2016

122 dBSPL

111 dBSPL

N/A

46 dB

N/A

41 dB

N/A

34 dB

200-7500 Hz

< 3%

< 3%

< 3%

< 26 dBSPL

N/A

8 mS @ 2kHz

30 mS @ 2kHz

0.85 mA

94 hrs

115 dBSPL

N/A

104 dBSPL

40 dB

34 dB

N/A

27 dB

N/A

200-7500 Hz

< 3%

< 3%

< 3%

< 26 dBSPL

N/A

8 mS @ 2kHz

30 mS @ 2kHz

0.85 mA

94 hrs

OU

TPU

T IN

dB

SP

L

OSPL 90 CURVE

250 500 1000 2000 4000 8000

2cc COUPLER CURVES

GA

IN IN

dB

FREQUENCY IN Hz

250 500 1000 2000 4000 8000

FREQUENCY RESPONSE CURVES

Reference Test Gain @ 60 dB

120

110

100

90

80

40

30

20

10

0

810 Series OSPL90 Maximum

OSPL90 @ 1600 Hz

HFAverage OSPL90

Peak Gain

HFA Full-On-Gain

Full-On-Gain @ 1600 Hz

Reference Test Gain

R.T.G @ 1600 Hz

Frequency Range (F1-F2)

THD at 500 Hz

800 Hz

1600 Hz

Equivalent Input Noise

Tele-Coil Sensitivity

Attack Time

Release Time

Battery Current Drain

Battery Life [10A]

IEC-118-0Ear Simulator

Thin Tube

ANSI S3.22-20032CC Coupler

Thin Tube

*AGCnotfullyactivated

Fitting Range

Hea

ring

Leve

l in

dB

Frequency in Hertz (Hz)

20

30

40

50

60

70

80

90

100

110

125 250 500 1000 2000 4000 8000750 1500 3000 6000

Open Ear w/ ZipTip

Semi-Occluded w/ ZipTip

Occluded w/ ZipTip

Actual Size

FREQUENCY IN Hz

Page 24: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

®

Evok625: Persona Medical introduces a newstyle of digital volume control. It’s easy and intuitive. Toggle up or down for subtle 2-3dB increases, and the VC automatically returns to the center. VC range and limits (up to 50dB) are con-trolled via NOAH compatible software.

1-800-789-6543

Features* Digital Processing*6 Channels; 12 Band equalizer* Expansion w/ Adjustable Ratios* Adaptive phase cancelling feedback shield* Tri-Mode Layered Noise Reduction* Digital VC w/ Adjustable Gain Increments* 4 Memories with Tone indicators* Tone adjustemens / level and frequency* Telecoil* Low level gain control* 312 Battery w/ low battery warning* Power on adjustable delay* OTE / BTE Earhook compatible* Speech Mapping Compatible w/

Graphic EQ Controls* Great Battery Life

Page 25: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

OSPL90 MaximumOSPL90 @ 1600 HzHFAverage OSPL90

Peak GainHFA Full-On-GainFull-On-Gain @ 1600 HzReference Test GainR.T.G @ 1600 Hz

Frequency Range (F1-F2)

THD at 500 Hz800 Hz1600 Hz

Equivalent Input NoiseTele-Coil Sensitivity

Attack TimeRelease Time

Battery Current DrainBattery Life [312]

M E D I C A L

®

Frequency Response Curves

Fitting Range

Out

put i

n dB

SPL

Hea

ring

Leve

l in

dB

Frequency in Hertz (Hz)

Frequency in Hertz (Hz)

Frequency in Hertz (Hz)

Gai

n in

dB

OSPL90 Curves

800.789.6543 | [email protected]

20

30

40

50

60

70

80

90

100

110

125 250 500 1000 2000 4000 8000750 1500 3000 6000

Med

20

30

40

50

60

70

80

90

100

110

125 250 500 1000 2000 4000 8000750 1500 3000 6000

Open Ear w/ ZipTip

Semi-Occluded w/ ZipTip

Occluded w/ ZipTip

Ear Hook

625 Series Open Ear ANSI S3.22-20032CC Coupler

Thin Tube / Earhook

120 / 127 dBSPL NA109 / 117 dBSPL

42 / 52 dB35 / 44 dBN/A33 / 40 dBN/A

200-8000 Hz

< 3%< 3%< 3%

< 26dB SPL 92 / 99 dBSPL

6 mS @ 2kHz* 30 mS @ 2kHz*

.85 / .95 mA200 / 170 Hrs

Features

• 100% Digital Processing Device

• 6 Channels; 12 Band equalizer

• Expansion w/ Adjustable Ratios

• Feedback Shield

• Tri-Mode Layered Noise Reduction

• Digital Volume Control w/ Adjustable Gain Increments / Ranges

• 4 Memories w/ Indicators

• Tone Adjustments / Level and Frequency Adjustments

• Telecoil

• Low Level Gain Control• Low Battery Warning w/indicator

• Battery 312 Zinc Air• Power on delay (adjustable)• OTE Tube / BTE Earhook Compatible• Speech Mapping Compatible w/ Graphic Equalizer Controls

IEC-118-0Ear Simulator

Thin Tube / Earhook

128 / 134 dBSPL 118 / 125 dBSPLN/A

50 / 60 dBN/A43 / 52 dBN/A41 / 48 dB

200 - 8000 HZ

< 3%< 3%< 3%

< 26 dB 99 / 106 dBSPL

6 mS @ 2kHz* 30 mS @ 2kHz*

.85/ .95 mA200 / 170 Hrs

90

100

110

120

130

1000200 500 2000 5000 80003000

20

30

40

50

60

1000200 500 2000 5000 80003000

Page 26: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

OSPL90 MaximumOSPL90 @ 1600 HzHFAverage OSPL90

Peak GainHFA Full-On-Gain

Full-On-Gain @ 1600 HzReference Test Gain

R.T.G @ 1600 Hz

Frequency Range (F1-F2)

THD at 500 Hz800 Hz

1600 HzSPLITS

Equivalent Input Noise

Attack TimeRelease Time

Battery Current DrainBattery Life [312]

ANSI S3.22-2003

2CC Coupler

Wide / Med / High

110 / 116 / 124 dB SPL N/A

104 / 112 / 120 dB SPL

40 / 50/ 55 dB35 / 45/ 50 dB

N/A27 / 35/ 43 dB

N/A

200 - 7500 Hz

< 3%< 3%< 3%

83 / 90 / 97 dB SPL

< 26 dB

6 mS @ 2kHz* 45 mS @ 2kHz*

.80 / .90 / 1.05 mA200 / 175 / 150Hrs

IEC-118-0Ear Simulator

Wide / Med / High

118 / 124 / 132 dB SPL 112 / 120 / 128 dB SPL

N/A

48 / 58/ 63 dBN/A

43 / 53/ 58 dBN/A

35 / 43/ 51 dB

N/A

N/AN/A

< 3%91/98/105/dB SPL

< 26 dB

6 mS @ 2kHz* 45 mS @ 2kHz*

.80 / .90 / 1.05 mA200 / 175 / 150Hrs

Features• Digital / Programmable• Hydroguard• Multi Memory Push Button• Programmable VC• Feedback Shield™• Tri-Mode Layered Noise Reduction• Telephone Coil• Dynamic Speech Enhancement (DSE)• 12 Bands, 2 Channels• 4 Programmable Memories• Memory Change Indicator w/ Adjustable Level

and Frequency• Low Battery Indicator• Wax Barrier/Wind Screen• NOAH Compatible• Three Power Levels: Wideband, Medium &

High Power• Speech-Pro™ Auto Fit (Optional)• Speech Mapping Compatible w/ Graphic

Equalizer Controls

M E D I C A L

®

OSPL90 CURVES

FREQUENCY RESPONSE CURVES

*AGC not fully activated

80

90

100

110

120

130

1000

Frequency in Hertz (Hz)

Out

put i

n dB

SPL

200 500 2000 5000 8000

Wide

High

Med

10

20

30

40

50

1000

Frequency in Hertz (Hz)

Gai

n in

dB

200 500 2000 5000 8000

Wide

High

Med

800.789.6543 | [email protected]

20

30

40

50

60

70

80

90

100

110

125 250 500 1000 2000 4000 8000750 1500 3000 6000

Hea

ring

Leve

l In

Deci

bels

(dB)

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

Frequency in Hertz (Hz)

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll

Wide

Med

High

RIC-520r

Page 27: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

OSPL90 MaximumOSPL90 @ 1600 HzHFAverage OSPL90

Peak GainHFA Full-On-GainFull-On-Gain @ 1600 HzReference Test GainR.T.G @ 1600 Hz

Frequency Range (F1-F2)

THD at 500 Hz800 Hz1600 Hz

Equivalent Input NoiseTele-Coil Sensitivity

Attack TimeRelease Time

Battery Current DrainBattery Life [312]

ANSI S3.22-20032CC Coupler

Thin Tube / Earhook

120 / 127 dBSPL N/A108 / 119 dBSPL

55 / 70 dB50 / 62 dBN/A31 / 42 dBN/A

200-5500 Hz

< 3%< 3%< 3%

< 27 / < 25 dB 91 / 102 dBSPL

10 mS @ 2kHz* 70 mS @ 2kHz*

.78 / .82 mA194 / 185Hrs

IEC-118-0Ear Simulator

Thin Tube / Earhook

127 / 134 dBSPL 116 / 128 dBSPLN/A

62 / 78 dBN/A56 / 68 dBN/A38 / 48 dB

N/A

N/AN/A< 3%

< 27 / < 25 dB 99 / 110 dBSPL

10 mS @ 2kHz* 70 mS @ 2kHz*

.78 / .82 mA194 / 185Hrs

Features

• 100% Digital Processing Device

• 2 Channels

• 12 Band Equalizer

• Feedback Shield

• Dynamic Speech Enhancement: (DSE)

• Noise Reduction

• Multi-function Digital Rocker: Volume / Memory

• 4 Memories w/ Indicators

• Tone/Level Adjustments

• Tele Coil

• Hydroguard™• Low Battery Warning w/indicator

• Mini BTE High Impact Case

• Battery 312 Zinc Air• OTE Tube / BTE Earhook Compatible• Speech Mapping Compatible w/ Graphic Equalizer ControlsM E D I C A L

®

Frequency Response Curves

Fitting Range

Out

put i

n dB

SPL

Hea

ring

Leve

l in

dB

Frequency in Hertz (Hz)

Frequency in Hertz (Hz)

Frequency in Hertz (Hz)

Gai

n in

dB

*AGC not fully activated

OSPL90 Curves

800.789.6543 | [email protected]

500 Series Open Ear

90

100

110

120

130

1000200 500 2000 5000 80003000

10

20

30

40

50

1000200 500 2000 5000 80003000

20

30

40

50

60

70

80

90

100

110

125 250 500 1000 2000 4000 8000750 1500 3000 6000

Open Ear w/ ZipTip

Semi-Occluded w/ ZipTip

Occluded w/ ZipTip

Ear Hook

Page 28: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

Features: _____________________________________________

• Feedback Shield• Enhanced Noise Reduction• Dynamic Speech Enhancement (DSE)• 12 Band, 2 Channel Processing• 4 Programmable Memories• Memory Change Indicator w/Adjustable

Level & Frequency• Low Battery Indicator• Wax Barrier/Wind Screen• Speech Mapping Compatible w/

Graphic Equalizer Controls• NOAH Compatible• 3D LazerVeyor Digital Shell Process

Options:

• SSVC with Enhanced Taper Control• Speech Pro Auto Fit• Power MatrixM E D I C A L

®

*AGC not fully activated

800.789.6543 | [email protected]

OSPL90 MaximumOSPL90 @ 1600 HzHFAverage OSPL90

Peak GainHFA Full-On-GainFull-On-Gain @ 1600 HzReference Test GainR.T.G @ 1600 Hz

Frequency Range (F1-F2)

THD at 500 Hz800 Hz1600 Hz

Equivalent Input Noise

Attack TimeRelease Time

Battery Current DrainBattery Life [10a]

ANSI S3.22-2003

2CC CouplerStandard/Power

115/120 dBSPLN/A

110/115 dBSPL

40/48 dB35/43 dB

N/A33/38 dB

N/A

200 - 8000 Hz

< 3%< 3%< 3%

< 26 dB SPL

6mS @ 2kHz* 30mS @ 2kHz*

.95/1.2 mA84/65 Hrs

IEC-118-0Ear SimulatorStandard/Power

123/128 dBSPL118/123 dBSPL

N/A

48/56 dBN/A

43/51 dBN/A

41/46 dB

N/A

N/AN/A

< 3%

< 26 dB SPL

6mS @ 2kHz* 30mS @ 2kHz*

.95/1.2 mA84/65 Hrs

FREQUENCY RESPONSE CURVE60 dB SPL input at RTG

OSPL90 Curves

500 Series CIC

0

10

20

30

40

50

60

70

80

90

125 250 500 1000 2000 4000 8000

Open Vent

Medium Vent

Small / No Vent

Frequency in Hertz (Hz)

Hea

ring

Thre

shol

d (d

B H

L)

0

10

20

30

40

50

1000

Frequency in Hertz (Hz)

Gain

in dB

200 500 2000 5000 8000

Power

Standard

Fitting Range

70

80

90

100

110

120

1000

Frequency in Hertz (Hz)

Outpu

t in dB

SPL

200 500 2000 5000 8000

Power

Standard

Page 29: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

Features: _____________________________________________• Manual VC w/ Enhanced Taper Control• Feedback Shield• Enhanced Noise Reduction• Dynamic Speech Enhancement (DSE)• 12 Band, 2 Channel Processing• 4 Programmable Memories• Memory Change Indicator w/Adjust- able Level & Frequency• Low Battery Indicator• Wax Barrier/Wind Screen• Speech Mapping Compatible w/ Graphic Equalizer Controls• NOAH Compatible• 3D LazerVeyor Digital Shell Process

Options:• Programmable Volume Control• SSVC with Enhanced Taper Control• Multi Memory Push Button• Speech Pro Auto Fit• Power MatixM E D I C A L

®

*AGC not fully activated

800.789.6543 | [email protected]

OSPL90 MaximumOSPL90 @ 1600 HzHFAverage OSPL90

Peak GainHFA Full-On-GainFull-On-Gain @ 1600 HzReference Test GainR.T.G @ 1600 Hz

Frequency Range (F1-F2)

THD at 500 Hz800 Hz1600 Hz

Equivalent Input Noise

Attack TimeRelease Time

Battery Current DrainBattery Life [10a]

ANSI S3.22-2003

2CC CouplerStandard/Power

115/120 dBSPLN/A

110/115 dBSPL

40/48 dB35/43dB

N/A33/38 dB

N/A

200 - 8000 Hz

< 3%< 3%< 3%

< 26 dB SPL

6mS @ 2kHz* 30mS @ 2kHz*

.95/1.2 mA84/65 Hrs

IEC-118-0Ear SimulatorStandard/Power

123/128 dBSPL118/123 dBSPL

N/A

48/56 dBN/A

43/51 dBN/A

41/46 dB

N/A

N/AN/A

< 3%

< 26 dB SPL

6mS @ 2kHz* 30mS @ 2kHz*

.95/1.2 mA84/65 Hrs

FREQUENCY RESPONSE CURVE60 dB SPL input at RTG

OSPL90 Curves

500 Series Mini Canal

0

10

20

30

40

50

60

70

80

90

125 250 500 1000 2000 4000 8000

Open Vent

Medium Vent

Small / No Vent

Frequency in Hertz (Hz)

Hear

ing

Thre

shol

d (d

B HL

)

0

10

20

30

40

50

1000

Frequency in Hertz (Hz)

Gain

in dB

200 500 2000 5000 8000

Power

Standard

Fitting Range

70

80

90

100

110

120

1000

Frequency in Hertz (Hz)

Outpu

t in dB

SPL

200 500 2000 5000 8000

Power

Standard

Page 30: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

Features: _____________________________________________• Manual VC w/ Enhanced Taper Control• Feedback Shield• Enhanced Noise Reduction• Dynamic Speech Enhancement (DSE)• 12 Band, 2 Channel Processing• 4 Programmable Memories• Memory Change Indicator w/Adjustable

Level & Frequency• Low Battery Indicator• Wax Barrier/Wind Screen• Speech Mapping Compatible w/ Graphic Equalizer Controls• NOAH Compatible• 3D LazerVeyor Digital Shell Process

Options:• Programmable Volume Control• Auto Telecoil• SSVC with Enhanced Taper Control• Multi Memory Push Button• Speech Pro Auto Fit• Power Matrix

M E D I C A L

®

*AGC not fully activated

800.789.6543 | [email protected]

OSPL90 MaximumOSPL90 @ 1600 HzHFAverage OSPL90

Peak GainHFA Full-On-GainFull-On-Gain @ 1600 HzReference Test GainR.T.G @ 1600 Hz

Frequency Range (F1-F2)

THD at 500 Hz800 Hz1600 Hz

Equivalent Input Noise

Attack TimeRelease Time

Telephone Coil Sensitivity(SPLITS)

Battery Current DrainBattery Life [312]

ANSI S3.22-2003

2CC CouplerStandard/Power

115/120 dBSPLN/A

110/115 dBSPL

50/58 dB45/53 dB

N/A33/38 dB

N/A

200 - 8000 Hz

< 3%< 3%< 3%

< 26 dB SPL

6mS @ 2kHz* 30mS @ 2kHz*

93/98 dB SPL

.95/1.2 mA160/126 Hrs

IEC-118-0Ear SimulatorStandard/Power

123/128 dBSPL118/123 dBSPL

N/A

58/66 dBN/A

43/51 dBN/A

41/46 dB

N/A

N/AN/A

< 3%

< 26 dB SPL

6mS @ 2kHz* 30mS @ 2kHz*

100/105 dB SPL

.95/1.2 mA160/126 Hrs

FREQUENCY RESPONSE CURVE60 dB SPL input at RTG

OSPL90 Curves

500 Series Canal

0

10

20

30

40

50

60

70

80

90

125 250 500 1000 2000 4000 8000

Open Vent

Medium Vent

Small / No Vent

Frequency in Hertz (Hz)

Hea

ring

Thre

shol

d (d

B H

L)

0

10

20

30

40

50

1000

Frequency in Hertz (Hz)

Gain

in dB

200 500 2000 5000 8000

Power

Standard

Fitting Range

70

80

90

100

110

120

1000

Frequency in Hertz (Hz)

Outpu

t in dB

SPL

200 500 2000 5000 8000

Power

Standard

Page 31: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

Features: _____________________________________________• Manual VC w/ Enhanced Taper Control• Feedback Shield• Enhanced Noise Reduction• Dynamic Speech Enhancement (DSE)• 12 Band, 2 Channel Processing• 4 Programmable Memories• Memory Change Indicator w/Adjust- able Level & Frequency• Low Battery Indicator• Wax Barrier/Wind Screen• Speech Mapping Compatible w/ Graphic Equalizer Controls• NOAH Compatible• 3D LazerVeyor Digital Shell Process

Options:• Programmable Volume Control• Auto Telecoil• SSVC with Enhanced Taper Control• Multi Memory Push Button• Speech Pro Auto Fit• Power Matrix• Directional Microphones

M E D I C A L

®

*AGC not fully activated

800.789.6543 | [email protected]

OSPL90 MaximumOSPL90 @ 1600 HzHFAverage OSPL90

Peak GainHFA Full-On-GainFull-On-Gain @ 1600 HzReference Test GainR.T.G @ 1600 Hz

Frequency Range (F1-F2)

THD at 500 Hz800 Hz1600 Hz

Equivalent Input Noise

Attack TimeRelease Time

Telephone Coil Sensitivity(SPLITS)

Battery Current DrainBattery Life [312]

ANSI S3.22-2003

2CC CouplerStandard/Power

115/120 dBSPLN/A

110/115 dBSPL

50/58 dB45/53 dB

N/A33/38 dB

N/A

200 - 8000 Hz

< 3%< 3%< 3%

< 26 dB SPL

6mS @ 2kHz* 30mS @ 2kHz*

93/98 dB SPL

.95/1.2 mA160/126 Hrs

IEC-118-0Ear SimulatorStandard/Power

123/128 dBSPL118/123 dBSPL

N/A

58/66 dBN/A

43/51 dBN/A

41/46 dB

N/A

N/AN/A

< 3%

< 26 dB SPL

6mS @ 2kHz* 30mS @ 2kHz*

100/105 dB SPL

.95/1.2 mA160/126 Hrs

FREQUENCY RESPONSE CURVE60 dB SPL input at RTG

OSPL90 Curves

500 Series Half Shell

0

10

20

30

40

50

60

70

80

90

125 250 500 1000 2000 4000 8000

Open Vent

Medium Vent

Small / No Vent

Frequency in Hertz (Hz)

Hea

ring

Thre

shol

d (d

B H

L)

0

10

20

30

40

50

1000

Frequency in Hertz (Hz)

Gain

in dB

200 500 2000 5000 8000

Power

Standard

Fitting Range

70

80

90

100

110

120

1000

Frequency in Hertz (Hz)

Outpu

t in dB

SPL

200 500 2000 5000 8000

Power

Standard

Page 32: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

Features: _________________________________________________• Manual VC w/ Enhanced Taper Control• Feedback Shield• Enhanced Noise Reduction• Dynamic Speech Enhancement (DSE)• 12 Band, 2 Channel Processing• 4 Programmable Memories• Memory Change Indicator w/Adjustable Level & Frequency• Low Battery Indicator• Wax Barrier/Wind Screen• Speech Mapping Compatible w/Graphic Equalizer Controls• NOAH Compatible• 3D LazerVeyor Digital Shell Process

Options:• Programmable Volume Control• SSVC with Enhanced Taper Control• Speech Pro Auto Fit• Power Matrix• Auto Telecoil• Directional Microphone• Rechargeable

M E D I C A L

®

*AGC not fully activated

800.789.6543 | [email protected]

OSPL90 MaximumOSPL90 @ 1600 HzHFAverage OSPL90

Peak GainHFA Full-On-GainFull-On-Gain @ 1600 HzReference Test GainR.T.G @ 1600 Hz

Frequency Range (F1-F2)

THD at 500 Hz800 Hz1600 Hz

Equivalent Input Noise

Attack TimeRelease Time

Telephone Coil Sensitivity(SPLITS)

Battery Current DrainBattery Life [13]

ANSI S3.22-2003

2CC CouplerStandard/Power

120/130 dBSPLN/A

115/124 dBSPL

55/65 dB50/60 dB

N/A38/47 dB

N/A

200 - 8000 Hz

< 3%< 3%< 3%

< 26 dB SPL

6mS @ 2kHz* 30mS @ 2kHz*

98/107 dB SPL

.95/1.2 mA284/180 Hrs

IEC-118-0Ear SimulatorStandard/Power

128/138 dBSPL123/132 dBSPL

N/A

63/72 dBN/A

58/68 dBN/A

46/55 dB

N/A

N/AN/A

< 3%

< 26 dB SPL

6mS @ 2kHz* 30mS @ 2kHz*

106/115 dB SPL

.95/1.2 mA284/180 Hrs

FREQUENCY RESPONSE CURVE60 dB SPL input at RTG

OSPL90 Curves

0

10

20

30

40

50

60

70

80

90

125 250 500 1000 2000 4000 8000

Open Vent

Medium Vent

Small / No Vent

Frequency in Hertz (Hz)

Hea

ring

Thre

shol

d (d

B H

L)

Fitting Range

500 Series Full Shell

Rechargeable........................8Hrs Charge yields 16Hrs Use

80

90

100

110

120

130

1000

Frequency in Hertz (Hz)

Outpu

t in dB

SPL

200 500 2000 5000 8000

Power

Standard

20

30

40

50

60

1000

Frequency in Hertz (Hz)

Gain

in dB

200 500 2000 5000 8000

Power

Standard

Page 33: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

Features

• Digital/Programmable• Telecoil• Hydrocoat• DigitalVolumeControlw/AudibleMax/Min• MultiMemoryPushButton• Volume/MemoryRetentionafterPowerCycle• FeedbackShield™• Tri-ModeLayeredNoiseReduction• DynamicSpeechEnhancement(DSE)• 12Bands,4Channels• 4ProgrammableMemories• MemoryChangeIndicatorw/AdjLevel/Freq• LowBatteryIndicator• NOAH/NOAHLinkCompatible• Speech-Pro™AutoFit

®

800.789.6543|[email protected]/2016

122 / 129 dBSPL

112 / 123 dBSPL

N/A

57 / 68 dB

52 / 60 dB

N/A

36 / 47 dB

200-6300 Hz

< 3%

< 3%

< 3%

< 25 dBSPL

95 / 107 dBSPL

10 mS @ 2kHz

70 mS @ 2kHz

0.95 mA

165 hrs

129 / 136 dBSPL

N/A

118 / 130 dBSPL

63 / 76 dB

N/A

58 / 70 dB

43 / 53 dB

N/A

< 3%

< 3%

< 3%

< 25 dBSPL

104 / 115 dBSPL

10 mS @ 2kHz

70 mS @ 2kHz

1.00 mA

160 hrs

400 Series OSPL90 Maximum

OSPL90 @ 1600 Hz

HFAverage OSPL90

Peak Gain

HFA Full-On-Gain

Full-On-Gain @ 1600 Hz

Reference Test Gain

R.T.G @ 1600 Hz

Frequency Range (F1-F2)

THD at 500 Hz

800 Hz

1600 Hz

Equivalent Input Noise

Tele-Coil Sensitivity

Attack Time

Release Time

Battery Current Drain

Battery Life [312]

IEC-118-0Ear Simulator

Thin Tube / Earhook

ANSI S3.22-20032CC Coupler

Thin Tube / Earhook

*AGCnotfullyactivated

Fitting Range

Hea

ring

Leve

l in

dB

Frequency in Hertz (Hz)

20

30

40

50

60

70

80

90

100

110

125 250 500 1000 2000 4000 8000750 1500 3000 6000

Open Ear w/ ZipTip

Semi-Occluded w/ ZipTip

Occluded w/ ZipTip

Ear Hook

Actual Size

OSPL 90 CURVETHIN TUBE BTE EARHOOK

Frequency Response Curves

Out

put i

n dB

SPL

Frequency in Hertz (Hz)

Frequency in Hertz (Hz)

Gai

n in

dB

OSPL90 Curves

20

30

40

50

60

1000200 500 2000 5000 80003000

90

100

110

120

130

1000200 500 2000 5000 80003000

Page 34: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

®

Page 35: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

Features

Digital / Non-Programmable3 Memories (Mic,Noise,Telecoil)Manual Volume ControlEnhanced Taper ControlMicrophone Noise ExpansionDynamic Speech Enhancement (DSE)12 Bands, 2 Channels ProcessingStandard 2 trimmers w/ linear taper TelecoilMemory Change IndicatorLow Battery IndicatorAGC-O LimitingHydrocoat moisture barrier (option)

Fitting Range

Hea

ring

Leve

l (dB

HL)

Frequency in Hertz (Hz)

0

10

20

30

40

50

60

70

80

90

100125 250 500 1000 2000 4000 8000

®

800.789.6543 | [email protected]

365 SeriesOSPL90 Maximum

OSPL90 @ 1600 HzHFAverage OSPL90

Peak GainHFA Full-On-Gain

Full-On-Gain @ 1600 Hz

Reference Test GainR.T.G @ 1600 Hz

Frequency Range (F1-F2)

THD at 500 Hz 800 Hz 1600 Hz

Equivalent Input NoiseTele-Coil Sensitivity

Attack TimeRelease Time

Battery Current DrainBattery Life [675]

IEC-118-0Ear Simulator

Earhook

ANSI S3.22-20032CC Coupler

Earhook

Gain Curves (RTG @ 60dB in)

OSPL90 Curves

Actual Size

HFLF

SPCL/365 /4 © 2017 PERSONA

Frequency in Hertz (Hz)

90

100

110

120

130

1000200 500 2000 80004000

Out

put d

BSPL

Frequency in Hertz (Hz)

Gai

n in

dB

30

20

40

50

60

70

1000200 500 2000 80004000

Trimmer ID

LF

HF+_

+_

++

_ _

• ••••••••••••

137 dBSPLN/A130 dBSPL

78 dB72 dBN/A

54dBN/A

200-4100 Hz

< 2%< 2%< 2%

< 22 dB 105 dBSPL 10 mS @ 2kHz*50 mS @ 2kHz*

1.97 mA300 hrs

145 dBSPL137 dBSPLN/A

86 dBN/A80 dB

N/A60 dB

N/A

< 2%< 2%< 2%

< 22 dB 111 dBSPL 10 mS @ 2kHz*50 mS @ 2kHz*

1.97 mA300 hrs

Memory 1 Memory 2

*AGC not fully activated

Page 36: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

Features

Digital / Non-ProgrammableHydrocoatManual Volume ControlEnhanced Taper ControlFeedback Shield™Microphone Noise ExpansionDynamic Speech Enhancement (DSE)12 Bands, 2 Channels ProcessingStandard 3 trimmers w/ linear taper TelecoilMemory Change IndicatorLow Battery IndicatorAGC-O LimitingHydrocoat moisture barrier (option)

Fitting Range

Hea

ring

Leve

l (dB

HL)

Frequency in Hertz (Hz)

0

10

20

30

40

50

60

70

80

90

100125 250 500 1000 2000 4000 8000

®

800.789.6543 | [email protected]

136 dBSPLN/A130 dBSPL

78 dB67 dBN/A

53 dBN/A

200-5100 Hz

< 3%< 2%< 2%

< 24 dB

116 dBSPL

10 mS @ 2kHz*50 mS @ 2kHz*

1.4 mA450 hrs

142 dBSPL137 dBSPLN/A

84 dBN/A74 dB

N/A59 dB

N/A

< 3%< 2%< 2%

< 24 dB

116 dBSPL

10 mS @ 2kHz*50 mS @ 2kHz*

1.4 mA450 hrs

360 SeriesOSPL90 Maximum

OSPL90 @ 1600 HzHFAverage OSPL90

Peak GainHFA Full-On-Gain

Full-On-Gain @ 1600 Hz

Reference Test GainR.T.G @ 1600 Hz

Frequency Range (F1-F2)

THD at 500 Hz 800 Hz 1600 Hz

Equivalent Input Noise

Tele-Coil Sensitivity

Attack TimeRelease Time

Battery Current DrainBattery Life [675]

IEC-118-0Ear Simulator

Earhook

ANSI S3.22-20032CC Coupler

Earhook

*AGC not fully activated

Gain Curves (RTG @ 60dB)

OSPL90 Curves

Actual Size

HFLF

SPCL/360 /4 © 2014 PERSONA

Frequency in Hertz (Hz)

90

100

110

120

130

1000200 500 2000 80004000

Out

put d

BSPL

Frequency in Hertz (Hz)

Gai

n in

dB

20

10

30

40

50

60

1000200 500 2000 80004000

Trimmer ID

LF HF

OC+_ + _

+_

+

++

_ _

_

•••••••••••••••

Page 37: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

Features

• Digital/Non-Programmable• Hydrocoat• DigitalVolumeControlw/AudibleMax/Min• Volume/MemoryRetentionVMRTMafter

PowerCycle• FeedbackShield™• Tri-ModeLayeredNoiseReduction• DynamicSpeechEnhancement• 12Bands,4ChannelsProcessing• Memories1-3(6dB/Octaveincrements)• TelecoilOption(Claret450;Memory4)• MemoryChangeIndicator• LowBatteryIndicator• ThintubeorEarhook

®

800.789.6543|[email protected]/2016

106 / 112 dBSPL

N/A

97 / 106 dBSPL

36 / 45 dB

30 / 39 dB

N/A

20 / 29 dB

200-6300 Hz

< 3%

< 3%

< 3%

< 29 / < 27 dBSPL

85 / 93 dBSPL

10 mS @ 2kHz

70 mS @ 2kHz

0.82 mA

195 hrs

113 / 119 dBSPL

104 / 113 dBSPL

N/A

43 / 52 dB

N/A

37 / 46 dB

27 / 36 dB

N/A

< 3%

< 3%

< 3%

< 25 / < 27 dBSPL

92 / 100 dBSPL

10 mS @ 2kHz

70 mS @ 2kHz

0.82 mA

195 hrs

400 Series & OSPL90 Maximum

OSPL90 @ 1600 Hz

HFAverage OSPL90

Peak Gain

HFA Full-On-Gain

Full-On-Gain @ 1600 Hz

Reference Test Gain

R.T.G @ 1600 Hz

Frequency Range (F1-F2)

THD at 500 Hz

800 Hz

1600 Hz

Equivalent Input Noise

Tele-Coil Sensitivity

Attack Time

Release Time

Battery Current Drain

Battery Life [312]

IEC-118-0Ear Simulator

Thin Tube / Earhook

ANSI S3.22-20032CC Coupler

Thin Tube / Earhook

*AGCnotfullyactivated

Fitting Range

Hea

ring

Leve

l in

dB

Frequency in Hertz (Hz)

0

10

20

30

40

50

60

70

80

90

125 250 500 1000 2000 4000 8000750 1500 3000 6000

Open Ear w/ ZipTip

Semi-Occluded w/ ZipTip

Occluded w/ ZipTip

or Ear Hook

BTE Curves

Frequency in Hertz (Hz)

ThinTube Curves

60

70

80

90

100

1000200 500 2000 5000 80003000

0

10

20

30

40

OUTPUT

Actual Size

Out

put i

n dB

SPL

Gai

n in

dB

MEMORY 1MEMORY 3

MEMORY 2

Frequency in Hertz (Hz)

60

70

80

90

100

110

1000200 500 2000 5000 80003000

0

10

20

30

40

OUTPUT

Out

put i

n dB

SPL

Gai

n in

dB

MEMORY 1 MEMORY 3

MEMORY 2

450 Series

Page 38: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

OPEN EAR / MINI BTE320 / 325 SPECIFICATIONS

OSPL90 Maximum

OSPL90 @ 1600 Hz

Peak Gain

Full-On-Gain @ 1600 Hz

R.T.G @ 1600 Hz

Frequency Range: f1-f2

THD at 500 Hz

800 Hz

1600 Hz

Eq. Input Noise Level

Attack Time

Release Time

Battery Current Drain

Battery Life (312)

130 /122 dBSPL

120 /112 dBSPL

50 /38 dB

45 /33 dB

44 /35 dB

200-7100 Hz

< 6% / < 3%

< 6% / < 3%

< 6% /< 3%

< 29 dBSPL

6 mS @ 2KHz

60 mS @ 2KHz

0.80 /0.70 mA

200 /225 hrs

OSPL90 Maximum

HF Average OSPL90

Peak Gain

HFA Full-On-Gain

Reference Test Grain

Frequency Range: f1-f2

THD at 500 Hz

800 Hz

1600 Hz

Eq. Input Noise Level

Attack Time

Release Time

Battery Current Drain

Battery Life [312]

122 /114 dBSPL

113 /104 dBSPL

42 /30 dB

37 /25 dB

36 /27 dB

200-7100 Hz

< 6% / < 3%

< 6% / < 3%

< 6% / < 3%

< 29 dBSPL

6 mS @2KHz

60 mS @ 2KHz

0.80 /0.70 mA

200 /225 hrs

*Test Settings Provided Upon Request

uu 100% Digital Processing

uu Adaptive Feedback Cancellations (AFC)

uu Dynamic Speech Enhancement (DSE)

uu Enhanced Taper Control (ETC) for VC or SSVC

uu Two Channel Processing

uu Water Resistant Side-Ported Microphone

uu Low Battery Warning

uu Multi-Memory Indicator

uu Claret 325 VC with 3 Environment Memories + Mute

uu Claret 320 SSVC and AFT with 3 Gain Memories + Mute

SPCL/320-325 /4 © 2008 PERSONA

Earhook Thin Tube

Occluded-Ear

Open-Ear

Semi-Occluded

HEA

RIN

G L

EV

ELS

IN

DEC

IBELS

(d

B)

FITTING RANGE0

20

40

60

80

100

125 250 500 1000 2000 4000 8000

FREQUENCY IN Hz

Ear Hook

AFT

SSVC

Trimmer Configuration

250 500 1000 2000 4000 8000

250 500 1000 2000 4000 8000

OU

TPU

T IN

dB

SP

L

FREQUENCY IN Hz

OSPL 90 CURVE130

120

110

100

90

GA

IN IN

dB

FREQUENCY IN Hz

50

40

30

20

10

250 500 1000 2000 4000 8000

FREQUENCY RESPONSE CURVES

GA

IN IN

dB

FREQUENCY IN Hz

40

30

20

10

0250 500 1000 2000 4000 8000

EFFECT OF AFT TRIMMER (320 0nly)

Max Cut

Ear Simulator [IEC-118-0]* Earhook / Thin Tube 2cc Coupler [ANSI S3.22-1996]* Earhook / Thin Tube

Page 39: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

330/ 335 SPECIFICATIONS

OSPL90 Maximum

OSPL90 @ 1600 Hz

Peak Gain

Full-On-Gain @ 1600 Hz

R.T.G @ 1600 Hz

Frequency Range: f1-f2

THD at 500 Hz

800 Hz

1600 Hz

Eq. Input Noise Level

Attack Time

Release Time

Telecoil Sensitivity

Battery Current Drain

Battery Life (13)

140 dBSPL

132 dBSPL

75-58 dB

71-51 dB

55 dB

200-6300 Hz

< 5%

< 5%

< 5%

< 28 dBSPL

8/ 30 mS @ 2KHz

40/ 200 mS @ 2KHz

115 dBSPL

0.95 mA

337 hrs

OSPL90 Maximum

HF Average OSPL90

Peak Gain

HFA Full-On-Gain

Reference Test Grain

Frequency Range: f1-f2

THD at 500 Hz

800 Hz

1600 Hz

Eq. Input Noise Level

Attack Time

Release Time

Telecoil Sensitivity

Battery Current Drain

Battery Life [13]

132 dBSPL

124 dBSPL

70-50 dB

63-43 dB

47 dB

200-6300 Hz

< 5%

< 5%

< 5%

< 28 dBSPL

8/ 30 mS @ 2KHz

40/ 200 mS @ 2KHz

107 dBSPL

0.95 mA

337 hrs*Test Settings Provided Upon Request

uu 100% Digital with Two Channel Processing uu Improved Adaptive Feedback Cancellations (AFC)uu Dynamic Speech Enhancement (DSE)uu Available Matrix: 132 /70, 132 /60 or 132 /50uu Enhanced Taper Control (ETC)uu Low Battery Warninguu Three Trimmers: Output, LF, HFuu Multi Memory: 330 /2 Memories: Microphone and T-Coil 335 /3 Memories: Microphones, DSE Noise Switch, T-Coiluu Batttery Door Lock (Optional)

SPCL/300-BTE /10 © 2007 PERSONA

Standard 330 335

Ear Simulator [IEC-118-0]* 330 AGC-o / 335-WDRC 2cc Coupler [ANSI S3.22-1996]* 330 AGC-o / 335-WDRC

HEA

RIN

G L

EV

ELS

IN

DEC

IBELS

(d

B)

FITTING RANGE0

20

40

60

80

100

125 250 500 1000 2000 4000 8000

FREQUENCY IN Hz

OU

TPU

T IN

dB

SP

L

FREQUENCY IN Hz

OSPL 90 CURVE130

120

110

100

90250 500 1000 2000 4000 8000

Max FOG 90dBSPL Input

Max Output Compression

GA

IN IN

dB

FREQUENCY IN Hz

60

50

40

30

20250 500 1000 2000 4000 8000

FREQUENCY RESPONSE CURVES

LF

LF / HF

HF

90

CR at 2:1

50 60 70 80 90

120

110

100

OutputdBSPL

Input dB SPL at 2kHz

Volume Control at Reference Test Gain

I/O & AGCCharacteristics

CR at 1:1 HFLF

Output

Trimmer Configuration

MM

BTE (BEHIND THE EAR)

Page 40: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

MINI CANAL AND CIC300 SPECIFICATIONS

OSPL90 Maximum

OSPL90 @ 1600 Hz

Peak Gain

Full-On-Gain @ 1600 Hz

R.T.G @ 1600 Hz

Frequency Range: f1-f2

THD at 500 Hz

800 Hz

1600 Hz

Eq. Input Noise Level

Attack Time

Release Time

Battery Current Drain

Battery Life (10A Zinc air)

122 /128 dBSPL

118 /123 dBSPL

48 /56 dB

43 /51 dB

41 /48 dB

200-8000 Hz

< 3%

< 3%

< 3%

< 29 dBSPL

6 mS @ 2KHz

60 mS @ 2KHz

0.80 /1.05 mA

100 /75 hrs

OSPL90 Maximum

HF Average OSPL90

Peak Gain

HFA Full-On-Gain

Reference Test Grain

Frequency Range: f1-f2

THD at 500 Hz

800 Hz

1600 Hz

Eq. Input Noise Level

Attack Time

Release Time

Battery Current Drain

Battery Life [10A Zinc Air]

114 /120 dBSPL

110 /115 dBSPL

40 /48 dB

35 /43 dB

33 /40 dB

200-8000 Hz

< 3%

< 3%

< 3%

< 29 dBSPL

6 mS @2KHz

60 mS @ 2KHz

0.80 /1.05 mA

100 /75 hrs

*Test Settings Provided Upon Request

uu 100% Digital Processing

uu Enhanced Taper Control (ETC) for VC* or SSVC

uu Improved Adaptive Feedback Cancellations (AFC)

uu Two Channel Processing

uu Dynamic Speech Enhancement (DSE)

uu Trimmers Available; Low Cut, High Cut and AGC-o

uu Low Battery Warning Indicator

uu Multi-Memory Indicator

uu Power (Optional)

*mini-canal only

SPCL/300-MCNL-CIC /4 © 2008 PERSONA

Standard Power

Ear Simulator [IEC-118-0]* Standard / Power 2cc Coupler [ANSI S3.22-1996]* Standard / Power

HEA

RIN

G L

EV

ELS

IN

DEC

IBELS

(d

B)

FITTING RANGE0

20

40

60

80

100

125 250 500 1000 2000 4000 8000

FREQUENCY IN Hz

OU

TPU

T IN

dB

SP

L

FREQUENCY IN Hz

OSPL 90 CURVE120

110

100

90

80250 500 1000 2000 4000 8000

Max FOG 90dBSPL Input

Max Output Compression

GA

IN IN

dB

FREQUENCY IN Hz

50

40

30

20

10250 500 1000 2000 4000 8000

FREQUENCY RESPONSE CURVES

GA

IN IN

dB

FREQUENCY IN Hz

40

30

20

10

0250 500 1000 2000 4000 8000

EFFECT OF HIGH / LOW TRIMMERS

Active Lowcut

Feedback Control

Page 41: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

300 SPECIFICATIONS

OSPL90 Maximum

OSPL90 @ 1600 Hz

Peak Gain

Full-On-Gain @ 1600 Hz

R.T.G @ 1600 Hz

Frequency Range: f1-f2

THD at 500 Hz

800 Hz

1600 Hz

Eq. Input Noise Level

Attack / Release Time

Tele-Coil Sensitivity

Battery Current Drain

Battery Life (312)

122 /128 dBSPL

118 /123 dBSPL

58 /66 dB

53 /61 dB

41 /46 dB

200-8000 Hz

< 3%

< 3%

< 3%

< 29 dBSPL

6 /60mS @ 2KHz

101 /106 dBSPL

0.80 /1.05 mA

178 /160 hrs

OSPL90 Maximum

HF Average OSPL90

Peak Gain

HFA Full-On-Gain

Reference Test Grain

Frequency Range: f1-f2

THD at 500 Hz

800 Hz

1600 Hz

Eq. Input Noise Level

Attack / Release Time

Tele-Coil Sensitivity

Battery Current Drain

Battery Life (312)

114 /120 dBSPL

110 /115 dBSPL

50 /58 dB

45 /53 dB

33 /38 dB

200-8000 Hz

< 3%

< 3%

< 3%

< 29 dBSPL

6 / 60 mS @ 2KHz

93 /98 dBSPL

0.80 /1.05 mA

178 /160 hrs

*Test Settings Provided Upon Request

Ear Simulator [IEC-118-0]* Standard / Power 2cc Coupler [ANSI S3.22-1996]* Standard / Power

uu 100% Digital Processing Device

uu Enhanced Taper Control (ETC) for VC or SSVC

uu T-Coil and Auto T-Coils Option

uu Improved Adaptive Feedback Cancellations (AFC)

uu Two Channel Processing

uu Dynamic Speech Enhancement (DSE)

uu Trimmers Available; Low Cut, High Cut and AGC-o

uu Directional Microphone; Fixed Hyper Cardioid

uu Low Battery Warning Indicator

uu Multi-Memory Indicator

uu Power (Optional)SPCL/300-HS-CNL /10 © 2007 PERSONA

120

110

100

90

80

OUTP

UT

IN d

B SP

L

FREQUENCY IN Hz

OSPL 90 CURVE

250 500 1000 2000 4000 8000

Max FOG 90dBSPL Input

Max Output Compression

GAIN

IN d

B

FREQUENCY IN Hz

50

40

30

20

10250 500 1000 2000 4000 8000

FULL ON GAIN CURVE - 50dB INPUT

GAIN

IN d

B

FREQUENCY IN Hz

40

30

20

10

0250 500 1000 2000 4000 8000

EFFECT OF HIGH / LOW TRIMMERS

Active Lowcut

Feedback Control

HEA

RIN

G L

EVEL

S IN

DEC

IBEL

S (

dB)

FITTING RANGE0

20

40

60

80

100

125 250 500 1000 2000 4000 8000

FREQUENCY IN Hz

Standard Power

HALF SHELL AND CANAL

Page 42: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

Hearing Protection

FULL SHELL / POWER300 SPECIFICATIONS

OSPL90 Maximum

OSPL90 @ 1600 Hz

Peak Gain

Full-On-Gain @ 1600 Hz

R.T.G @ 1600 Hz

Frequency Range: f1-f2

THD at 500 Hz

800 Hz

1600 Hz

Eq. Input Noise Level

Attack / Release Time

Tele-Coil Sensitivity

Battery Current Drain

Battery Life (13)

128 /136 dBSPL

122 /131 dBSPL

64 /73 dB

58 /68 dB

45 /54 dB

200-6700 Hz

< 3%

< 3%

< 3%

< 26 dBSPL

6 / 60 mS @ 2KHz

105 /114 dBSPL

0.95 /1.2 mA

337 /228 hrs (13)

OSPL90 Maximum

HF Average OSPL90

Peak Gain

HFA Full-On-Gain

Reference Test Grain

Frequency Range: f1-f2

THD at 500 Hz

800 Hz

1600 Hz

Eq. Input Noise Level

Attack / Release Time

Tele-Coil Sensitivity

Battery Current Drain

Battery Life [13]

120 /128 dBSPL

114 /123 dBSPL

56 /65 dB

50-35 /60-35 dB

37 /46 dB

200-6700 Hz

< 3%

< 3%

< 3%

< 26 dBSPL

6 /60 mS @ 2KHz

97 /106 dBSPL

0.95 /1.2 mA

337 /228 hrs (13)

*Test Settings Provided Upon Request

Ear Simulator [IEC-118-0]* Standard / Power 2cc Coupler [ANSI S3.22-1996]* Standard / Power

0

20

40

60

80

100

125 250 500 1000 2000 4000 8000Frequency in Hz

Hear

ing

Thre

shol

d

Leve

ls in

dB

FITTING RANGESTANDARD

0

20

40

60

80

100

125 250 500 1000 2000 4000 8000Frequency in Hz

Hear

ing

Thre

shol

d Le

vels

in d

B

FITTING RANGEPOWER uu 100% Digital Processing Device

uu Enhanced Taper Control (ETC) for VC or SSVC

uu T-Coil and Auto T-Coils Option

uu Improved Adaptive Feedback Cancellations (AFC)

uu Two Channel Processing

uu Dynamic Speech Enhancement (DSE)

uu Trimmers Available; Low Cut, High Cut and AGC-o

uu Directional Microphone; Fixed Hyper Cardioid

uu Low Battery Warning Indicator

uu Multi-Memory Indicator

130

120

110

100

90

OUTP

UT

IN d

B SP

L

FREQUENCY IN Hz

OSPL 90 CURVE

250 500 1000 2000 4000 8000

Max FOG 90dBSPL Input

Max Output Compression

GAIN

IN d

B

FREQUENCY IN Hz

60

50

40

30

20250 500 1000 2000 4000 8000

FREQUENCY RESPONSE CURVES

GAIN

IN d

B

FREQUENCY IN Hz

50

40

30

20

10250 500 1000 2000 4000 8000

EFFECT OF HIGH / LOW TRIMMERS

Active Lowcut

Feedback Control

SPCL/300-FS /10 © 2007 PERSONA

Standard Power

Page 43: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

Hearing Protection

Page 44: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

�-t'� The Instant "Custom" Mold

M E D I C A L

800. 789.6543

person medical.com

ZipTips are changing the way we fit hearing aids. Forget the hassle of custom molds and switch to the quickest, most efficient and most comfortable mold available on H1e market today.

ADVANTAGES:

• NO Impressions

• NO waiting for molds to be made

• NO Shipping fees for custom molds

• Increased Gain

• Increased Output

• Reduced Feedback

• Increased Low Frequency Gain

• Non-Occluding

• Places the seal at the aperture.,

where it belongs.

• Adjustable Venting

• Adjustable Depth

• Medical Grade Silicone

• Colored for easy R L Identification

• Secure and Comfortable

• Washable

Page 45: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

• VirtuallyInvisible• ClearSounding• Affordable• Reusable• Comfortable

EARasers.netinfo@earasers.net800-789-6543ADivisionofPersonaMedical

PatentPending

Page 46: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

---;

■■■ I■■■ I■■■I■■■I■■■ I■■■ I■■■I■■■ I■■■ I■■■ I■■■ I■■■ I■■■ I■■■ I■■■ I■■■ I■■■ I■■■ I

Page 47: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation
Page 48: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

HEARING PROTECTION THAT FOCUSES

ON HEARING

Acoustically clear

No plugged up feeling

Virtually invisible

100% Guaranteed

No sweat

No tickle

No itch

Affordable

Reusable

Comfortable

Replaces custom earplugs

Renewable

Hearing Clearly MattersTM

Clearly Hearing MattersTM

PRESERVES MUSICAL LAYERING

and

HIGH FREQUENCY SIBILANCE

Filtering in the ear canal, not outside your head Relieves the “barrel sound” effect

PATENTED SMART SEALTM

Page 49: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation
Page 50: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

AMERICA’S FAVORITEHIGH FIDELITY EARPLUG

THE ONLY GUARANTEED EARPLUG

FOR ALL MUSICIANS, SINGERS, CONCERT-GOERS, TEACHERS, DRUMLINES, HORN PLAYERS...

Call 1-800-789-6543for Band Program Discounts

www.earasers.com

TM

Page 51: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation
Page 52: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

Made with bright, fun colors, our Splash™ swim plugs help keep water from get-ting into your ears. You can choose from eight great colors or mix colors to-gether for a really cool look, like favorite school or team colors. Whatever color you choose, our Splash™ swim plugs are a fun way to protect those precious ears!

Plus, they come with built-in insertion and removal handles!

Splash™ Swim Plugs:

• Float• Easy to handle• Fun & colorful• Reusable• Reduce the chance of ear infections• Soft Silicone

TM

Page 53: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

TM

Page 54: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

'� new paradigm. Eclipses all other

universal in ear monitors. Comfort­

able & secure, clarity and power, head­

room & smooth dynamics, all perfectly balanced .. ./ thought I left my body!"

Stephen Ambrose - Inventor of the In Ear Monitor

t:1NEARZ � AU DIO

www.inearz.com

[email protected]

Page 55: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

Hearing protection focused on hearing

USA Manufactured www.earasers.com

BigSh tsTM

Page 56: 20 - Persona Medical · Sombra 8r series - Features Speech-Focus™ Null Tracking Directional Microphones ALL-IN-ONE™ Adaptive Speech Enhancement Feedback path eliminator Auto-Adaptation

170 N. CYPRESS WAY CASSELBERRY, FL 32707

407.339.2422 PERSONAMEDICAL.COM

2019