2 solutions for noninvasive blood pressure measurement

26
www.emka.fr www.emka.fr smart tools – swift services – sharp research 2 solutions for noninvasive blood pressure measurement emkaPACK & nibpSNAPSHOT

Upload: emka-technologies

Post on 31-May-2015

1.383 views

Category:

Technology


4 download

DESCRIPTION

emkaPACK and nibpSNAPSHOT

TRANSCRIPT

Page 1: 2 solutions for noninvasive blood pressure measurement

www.emka.frwww.emka.fr

smart tools – swift services – sharp

research

2 solutionsfor noninvasive blood pressuremeasurement

emkaPACK & nibpSNAPSHOT

Page 2: 2 solutions for noninvasive blood pressure measurement

www.emka.fr

noninvasive blood pressuremeasurement

A

B

C

D

overview

emkaPACK

nibpSNAPSHOT

software analysis

Page 3: 2 solutions for noninvasive blood pressure measurement

www.emka.fr

overview

A

Page 4: 2 solutions for noninvasive blood pressure measurement

www.emka.fr

what is NIBP?a noninvasive method for measuring the blood pressure of laboratory animals (dog, primates, etc.)

Page 5: 2 solutions for noninvasive blood pressure measurement

www.emka.fr

how does it work?

emka TECHNOLOGIES’ noninvasive blood pressure systems are based on the oscillometric technique: pressure is measured from a cuff around a limb or the tail that is inflated to block blood flow then deflated slowly

Page 6: 2 solutions for noninvasive blood pressure measurement

www.emka.fr

what is analyzed?

time

cuff pressure

Page 7: 2 solutions for noninvasive blood pressure measurement

www.emka.fr

2 different solutionsemkaPACKnibp is an optional feature of our emkaPACK noninvasive telemetry system - suitable for long term measurements on unrestrained animals

nibpSNAPSHOTself-contained, handheld device designed for single-point measurements

both supplied with dedicated software for data acquisition & analysis

Page 8: 2 solutions for noninvasive blood pressure measurement

www.emka.fr

common features

low and high pressure range 0-300mmHgadjustable deflation speed5mmHg/s – 15mmHg/slinear deflation speedhigh speed servo-control by instant pressure and dPdtadjustable pulse amplification 5x-100x

Page 9: 2 solutions for noninvasive blood pressure measurement

www.emka.fr

emkaPACK

B

Page 10: 2 solutions for noninvasive blood pressure measurement

www.emka.fr

designed for the emkaPACK systemsingle-shot or programmable cyclic operationembedded calibration information

Page 11: 2 solutions for noninvasive blood pressure measurement

www.emka.fr

setting-up the animal

tail is shaved

cuff is wrapped around the tail and connected to the transmitter

a custom velcro extension protects the cuff, and maintains it in the proper position on the tail

Page 12: 2 solutions for noninvasive blood pressure measurement

www.emka.fr

nibpSNAPSHOT

C

Page 13: 2 solutions for noninvasive blood pressure measurement

www.emka.fr

nibpSNAPSHOT

Page 14: 2 solutions for noninvasive blood pressure measurement

www.emka.fr

features

handheld deviceUSB connection to computerpowered through USBboth a NIBP device and a 7-leads ecg devicedesigned for single-point measurementsmeasurements can be repeated every 10s if necessary

Page 15: 2 solutions for noninvasive blood pressure measurement

www.emka.fr

specifications

Page 16: 2 solutions for noninvasive blood pressure measurement

www.emka.fr

software analysis

D

Page 17: 2 solutions for noninvasive blood pressure measurement

www.emka.fr

real-time & off-line software analysis

real-time analysis performed by iox2 (nibpSNAPSHOT, emkaPACK, emkaPACK 4G)

off-line analysis performed by ecgAUTO (nibpSNAPSHOT, emkaPACK, TOE)

control by iox2

ecgAUTO

Page 18: 2 solutions for noninvasive blood pressure measurement

www.emka.fr

parameters computed from the deflation curve alone

systolic blood pressurediastolic blood pressuremean blood pressure

ecgAUTO

Page 19: 2 solutions for noninvasive blood pressure measurement

www.emka.fr

parameters computed with simultaneous ecg

heart ratepressure transit time

ecgAUTO

Page 20: 2 solutions for noninvasive blood pressure measurement

www.emka.fr

pulse amplitude vs cuff pressure

pressure pulses and ecg

cuff pressure vs time

real-time analysis in iox2

Page 21: 2 solutions for noninvasive blood pressure measurement

www.emka.fr

pulse amplitude vs cuff pressure

pressure pulses and ecg

cuff pressure vs time

off-line analysis in ecgAUTO

Page 22: 2 solutions for noninvasive blood pressure measurement

www.emka.fr

how is analysis performed?

detects inflation cyclesapplies hi-pass filterselects valid blood pressure pulsesproduces bell shaped amplitude curvecomputes mean, systolic and diastolic pressure values

ecgAUTO

Page 23: 2 solutions for noninvasive blood pressure measurement

www.emka.fr

what are the challenges for a successful analysis?

when signal is noisy the algorithm picks pulses that correspond to blood pressure beats and ignores artefacts

for greater efficiency, the software applies a number of criteria and rejects unreliable or spurious results

present experience (around 1000 hours of data from 40 dogs) indicate that from 70 to 95% of inflation cycles produce reliable data

Page 24: 2 solutions for noninvasive blood pressure measurement

www.emka.fr

examples of good and poor quality signals

pulses from noisy zones are ignored

Page 25: 2 solutions for noninvasive blood pressure measurement

www.emka.fr

www.emka.fr

facebook :

twitter : @emkaTECH

www.facebook.com/emkaTECHNOLOGIES

Page 26: 2 solutions for noninvasive blood pressure measurement

www.emka.frwww.emka.fr

solutions for lifesciences research