146

Cooling and Heating type Single Phase and Three Phase

For small-scale commercial and residential use.Panasonic 2-Pipe Mini ECOi, the 2-Pipe heat pump is specifically designed for the most demanding applications. Mini ECOi is available in 5 sizes with cooling capacities ranging from 12.1kW to 28kW and connectable up to 15 indoor units (applicable for 28kW).An expansion from the Panasonic VRF line up, the Mini ECOi is compatible with the same indoor units and controls as the rest of the ECOi range.

Wide design operation conditions.The operating range for heating operation is to -20°C, the cooling range is to -10°C. The remote controller temperature setting offers a range from 16°C to 30°C.

Increased piping length for greater design fl exibility

Adaptable to various building types and sizes.Actual piping length: 120m (equivalent piping length 140m).Maximum piping length: 150m.

Up to 15 indoor units per system

System / HP 4HP 5HP 6HP 8HP 10HPMaximum number of connectable indoor units

6 8 9 15 15

Flexible pipework

Category Item DescriptionMax length (m)

Allowable pipework length

L1 Maximum pipe runActual length 120Equivalent length 140

L2-L3Difference between maximum length and minimum length from the first distribution joint

40

L3 L4 Ln Maximum length of each distribution joint 30L1+L3+L4 Maximum total pipe run length 150

Allowable height difference

H1When outdoor unit installed higher 50When outdoor unit installer lower 40

H2 Maximum difference between indoor units 15

L3 L4 H2

L2Ln

L1

H1

-15 -10 -5 0 5 10 15 20 25 30 35 40 45 50

-25 -20 -15 -10 -5 0 5 10 15 20

Cooling design operation conditions

Heating design operation conditions

Cooling: Outside air temperature ˚C (DB). Heating: Outside air temperature ˚C ( WB).Units work continuously at out of above condition until safety function starting.

46°C

18°C

Farthest pipe length (from outdoor unit to farthest indoor unit) (equivalent length):

120m

Maximum total pipe length:

150m

Maximum height difference between outdoor unit and indoor unit:

50m*

Maximum height difference between indoor units:

15m

* 40m if the outdoor unit is below the indoor unit.

Panasonic has unveiled its new, large capacity, Mini VRF side blow system. Available now from 4 to 10HP, this compact system is the ideal solution for applications where outdoor space is at a minimum, but where a quality and reliable heating and cooling solution is paramount.

Heating and cooling solutions

Perfect solution for small shops, offices, large residential properties or condominiums where outdoor space is minimal, as well as larger, commercial applications including hotels or larger office buildings where the outdoor system should not intrude on the exterior décor.

Bluefi n (only for 8-10HP)

Bluefin treatment protect the coil itself against corrosion, ensuring that the unit continues to function with the same outstanding thermal exchange efficiency and performance over time.

New Inverter compressor (only for 8-10HP)

Thanks to its top class COP, high heat exchange performance due to its wide heat exchanger and extensive Inverter compressor range, which provides a high efficiency operation by the load, it is also incredibly energy saving.

Silent mode

Maximum 7dB(A) can be reduced by setting. External input signal is also available. In case of the installation at Condominium, quiet operation performance is important, especially in night time.

147

NEW / VRF SYSTEMS / ECOi

COOLING MODE

-10°CHEATING MODE

-20°C5 YEARS

COMPRESSOR WARRANTY

Panasonic’s new Mini VRF system combines a high performance to position itself as one of the most compact and powerful VRF systems available within the European market.

For light commercial use

Panasonic’s Mini ECOi, the 2-Pipe heat pump small VRF system, is specifically designed for the most demanding applications. Offering between 12.1kW and 15.5kW cooling capacity in 3 sizes and up to 9 indoor units connected, the Mini ECOi sets standards of performance and flexibility. Utilising R410A and DC inverter technology, Panasonic offers VRF to a new and growing market.Forming a new key part of the Panasonic VRF line up, the Mini ECOi is compatible with the same indoor units and controls as the rest of the ECOi range.

Technical focus

· Single Phase or Three Phase power supply· One Amp start current· DC inverter technology combined with R410A· Diversity ratio 50~130%· Cooling operation to -10°C· Compact outdoor unit 1330 x 940 x 410mm

MINI ECOiHIGH EFFICIENCY 4-6HP

HP 4HP 5HP 6HP

Model U-4LE1E5 U-4LE1E8 U-5LE1E5 U-5LE1E8 U-6LE1E5 U-6LE1E8

Power supplyVoltage V 220 230 240 380 400 415 220 230 240 380 400 415 220 230 240 380 400 415Phase Single Phase Three Phase Single Phase Three Phase Single Phase Three PhaseFrequency Hz 50Hz 50Hz 50Hz 50Hz 50Hz 50Hz

Cooling capacity kW 12.1 12.1 14.0 14.0 15.5 15.5EER 1) W/W 4.30 4.30 4.20 4.20 3.45 3.45Running amperes A 13.9 13.3 12.7 4.9 4.7 4.5 16.3 15.6 14.9 5.7 5.4 5.2 21.5 20.5 19.7 7.5 7.1 6.9Input power cooling kW 2.81 2.81 3.33 3.33 4.49 4.49Heating capacity kW 12.5 12.5 16.0 16.0 18.0 18.0COP 1) W/W 4.62 4.62 4.30 4.30 3.95 3.95Running amperes A 13.2 12.7 12.1 4.7 4.5 4.3 18.0 17.2 16.5 6.3 6.0 5.8 21.6 20.7 19.8 7.5 7.2 6.9Input power heating kW 2.71 2.71 3.72 3.72 4.56 4.56Starting amperes A 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0Maximum amperes A 21.0 21.0 21.0 8.5 8.5 8.5 24.5 24.5 24.5 10.0 10.0 10.0 28.0 28.0 28.0 12.0 12.0 12.0Maximum Input power kW 4.44 4.64 4.84 5.15 5.42 5.62 5.17 5.41 5.64 6.06 6.37 6.61 5.91 6.18 6.45 7.27 7.65 7.94Maximum number of connectable indoor units 6 6 8 8 9 9Air volume Cooling / Heating m³/min 95 95 104 104 104 104

Sound pressureCooling (Hi / Lo) dB(A) 50 / 47 50 / 47 51 / 48 51 / 48 52 / 49 52 / 49Heating (Hi / Lo) dB(A) 52 / 49 52 / 49 53 / 50 53 / 50 55 / 52 55 / 52

Sound powerCooling (Hi) dB 68 68 69 69 70 70Heating (Hi) dB 70 70 71 71 73 73

Dimensions H x W x D mm 1330 x 940 x 340 1330 x 940 x 340 1330 x 940 x 340 1330 x 940 x 340 1330 x 940 x 340 1330 x 940 x 340Net weight kg 104 103 104 103 104 103

Piping connectionsLiquid pipe Inch (mm) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)Gas pipe Inch (mm) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 3/4 (19.05) 3/4 (19.05)

Refrigerant (R410A) kg / TCO2 Eq. 3.5 / 7.308 3.5 / 7.308 3.5 / 7.308 3.5 / 7.308 3.5 / 7.308 3.5 / 7.308

Operating rangeCooling Min ~ Max °C -10 ~ +46 -10 ~ +46 -10 ~ +46 -10 ~ +46 -10 ~ +46 -10 ~ +46Heating Min ~ Max °C -20 ~ +24 / -20 ~ +18 -20 ~ +24 / -20 ~ +18 -20 ~ +24 / -20 ~ +18 -20 ~ +24 / -20 ~ +18 -20 ~ +24 / -20 ~ +18 -20 ~ +24 / -20 ~ +18

1) EER and COP classification is at 400 V in accordance with EU directive 2002/31/EC.

5 YEARS COMPRESSOR WARRANTY: Exclusively for PRO Partners.

148

COOLING MODE

-10°CBLUEFIN HEATING MODE

-20°C5 YEARS

COMPRESSOR WARRANTY

Prepare to be blown away by Panasonic’s New Mini VRF system. The New Mini VRF compact system is the ideal solution for minimum outdoor space. Panasonic extends the Mini VRF range by 8 and 10HP units.

Increase external static pressure

When unit is installed at the narrow balcony, the fence at front side will be the obstacle. High external static pressure feature will keep the operating capacity and good advantage.

High ambient temperature performance

Cooling operation range up to 46°C. The system can maintain the rated (100%) capacity up to 40°C by 8HP model & up to 37°C by 10HP model.

Technical focus

· Piping flexibility 150m maximum piping length· High efficiency· 15 indoor units connectable· Quiet operation mode (one of the lowest in the market)· High ambient temp performance· High static pressure 35Pa

MINI ECOi HIGH EFFICIENCY 8-10HP

HP 8HP 10HP

Model U-8LE1E8* U-10LE1E8*

Power supplyVoltage V 380 400 415 380 400 415Phase Three Phase Three PhaseFrequency Hz 50Hz 50Hz

Cooling capacity kW 22.40 28.00EER 1) W/W 3.80 3.11Running amperes A 9.60 9.15 8.80 14.70 14.00 13.50Input power cooling kW 5.89 9.00Heating capacity kW 25.00 28.00COP 1) W/W 4.02 3.93Running amperes A 10.20 9.65 9.30 11.60 11.10 10.70Input power heating kW 6.22 7.13Starting amperes A 1.00 1.00Maximum amperes A 13.70 19.60Maximum Input power kW 9.16 13.10Maximum number of connectable indoor units 15 2) 15 2)

External static pressure Pa 0 ~ 35 0 ~ 35Air volume Cooling / Heating m³/min 150 160

Sound pressureCooling dB(A) 60 63Cooling (Silent 1 / 2 / 3) dB(A) 57 / 55 / 53 60 / 58 / 56Heating dB(A) 64 65

Sound power Cooling / Heating dB 81 / 85 84 / 86Dimensions / Net weight H x W x D mm / kg 1500 x 980 x 370 / 132 1500 x 980 x 370 / 133

Piping connectionsLiquid pipe Inch (mm) 3/8 (9.52) 3) / 1/2 (12.70) 4) 3/8 (9.52) 3) / 1/2 (12.70) 4)

Gas pipe Inch (mm) 3/4 (19.05) 3) / 7/8 (22.22) 4) 7/8 (22.22) 3) / 1 (25.40) 4)

Max piping length range (total) m 7.5 ~ 150 (7.5 ~ 300) 7.5 ~ 150 (7.5 ~ 300)Elevation difference (in/out) m 50 (Outdoor unit upper) / 40 (Outdoor unit lower) 50 (Outdoor unit upper) / 40 (Outdoor unit lower)Refrigerant (R410A) kg / TCO2 Eq. 6.3 (24.0) / 13.1544 6.6 (24.0) / 13.7808Maximum allowable indoor / outdoor capacity ratio % 50 ~ 130 50 ~ 130Operating range Cooling / Heating Min ~ Max °C -10 ~ +46 / -20 ~ +18 -10 ~ +46 / -20 ~ +18

1) EER and COP classification is at 400 V in accordance with EU directive 2002/31/EC. 2) If the heating utilized, it is necessary to increase 1 size with respect to the main liquid pipe, depending on the combination of the indoor unit. 3) Under 90m for ultimate indoor unit. 4) Over 90m for ultimate indoor unit. If the longest piping equivalent length exceeds 90m, increase the sizes of the main tubes by 1 rank for gas and liquid pipes. * Tentative data.

Rating Conditions: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 35°C DB. Heating Indoor 20°C DB. Heating Outdoor 7°C DB / 6°C WB. (DB: Dry Bulb; WB: Wet Bulb)Specifications subject to change without notice. For detailed information about ErP, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.

5 YEARS COMPRESSOR WARRANTY: Exclusively for PRO Partners.