  • WAFS - 103 Differential Pressure Pitot Tube Flow Meter

    Specially Designed with PatentedAnti Condensation TechnologyKey Features :

    Suitable for Wet Compressed AirInsertion Type With Anti Ejection DesignIdeal for Compressor FAD MeasurementStandard Options Include Built in Temperature andPressure SensorsIntegrated Display With Touch Functions and OptionalData LoggingBluetooth Interface For Easy ConfigurationSupports WiseAir 4.0 Bluetooth Mobile Application(Android Version)

    Flow

    Pressure

    Temperature

    Ambient Temperature

    Process Medium

    Applications

    Accuracy

    Signals

    Input

    Anti Condensate

    Power Up EMC

    Display

    Data Logger

    Suitable for Pipe Sizes

    Available Shaft Lengths

    Electrical Connection

    Process Connection

    Calibration Frequency

    Parameters

    Measuring Range

    Accuracy

    Outputs

    Power Supply

    Display & Data Logging

    Other Informations

    10..300 Nm/s

    0 to 16 Bar

    0 0 0 0-40 C to +200 C / -40 C to +392 C

    0 0-20 C to + 60 C

    Air, Argon, Carbon Dioxide, Helium, Hydrogen,

    Natural Gas, Nitrogen, Nitrous Oxide, Oxygen

    Wet and Dry Air High Velocities

    Flow: ±(1% reading + 0.3% full scale)

    Pressure : ±0.5% Full Scale

    0Temperature : 0.5 C

    Analog (4..20mA (4Wire, Isolated) / Pulse Output

    Digital : RS485 Modbus / RTU

    Flow, Consumption, Pressure and Temperature

    18 to 30V / 6.5W@24V

    18 to 30V/ 24W@24V

    According to IEC 61326-1

    2.8” LCD With Touch Panel

    10,000,000 Samples

    DN 25 to DN 600

    250 mm & 400 mm

    2 x 5 pin, M12, Female

    ISO G1/2” Thread

    Every 2 Years

    l

    l

    l

    l

    l

    l

    l

    2

    Asia Regional Office Europe Regional Office

    www.systel.asia

    Pilestraede 58, 1112 CopenhagenDenmark. Ph : +45 36990422

    [email protected]

    Authorised Distributors Of :

  • Pipe Size

    WAFS 103

    WAFS 103 - A

    Pitot Tube Flow Sensor 0 (5) …30 Nm/s with 250 mm Shaft With Modbus / Pulse / 4..20mA Output and Bluetooth CompatibilityPitot Tube Flow Sensor 0 (5) …30 Nm/s with 400 mm Shaft With Modbus / Pulse / 4..20mA Output and Bluetooth Compatibility

    Flow Range (Nm3/h) Flow Range (cfm)

    WAFS - 103 Differential Pressure Pitot Tube Flow Meter

    Flow Ranges

    Ordering Codes

    Inches

    11 ¼1 ½22 ½345681012

    253240506580100125150200250300

    253240506580100125150200250300

    8.814.522.635.359.790.5141.4

    220.9318.1

    565.5883.61272.3

    53086813572120358354288482

    1325319085339295301476340

    5.178.5313.3

    20.7735.1353.2586.21129.99187.2

    332.79519.99748.74

    311.9510.81798.591247.622108.593194.374991.657799.3911231.5219967.2231198.74

    44926.09

    DN ID (mm) Min Flow Min Flow Max Flow Max Flow

    Installation Reference - 1

    Correct InstallationThe sensor tip must be in the center of the pipe / tube.