1.system introduction 2.new board description introduction to ip ldk-100/300/300e digital key...
TRANSCRIPT
1. System Introduction2. New Board Description
Introduction to IP LDK-100/300/300EDigital Key Telephone System
1. System IntroductionSystem Overall Configuration
WTIB
STIB : So
DTIB
SLIB
LCO
BRI
PRI
E1
LA
N:1
0M E
the
rne
t
RF Base
CTI/TAPIServer
PCAdmin
PCAttendant
PCPhone
Billing/PMS
VoiceMail
WANRouter Hub (10/100M)
DKTU SLT
DECT
Video Phone(ISDN Based)
Data Network areaData Network area
RS232C
PFTU BatteryExt MOHExt. PagingLoud Bell(Relay)
G4 FaxISDN Phone
VoiceMail
PSTN
ISDN
Internet
LCO
B
LDK-50/100 MB Iss: Rev:
ED 3667
LCO
B MP
B
LDK-50/100 MB Iss: Rev:
ED 3667
LCO
B
LCO
B
Remote Services Gateway
DKTU SLT PC
PSTN
WAN
Voice Networking(PRI)
Voice Networking (VoIP)
IP VoIP
VMIB (Voice Announcement Service)
IP Phone
PrinterVoice MailBilling/PMSPC Admin
1/16
1. System Introduction
LDK-300/300E
KSU
-. KSU : Key Service Unit-. MPB : Main Processor Board-. MPBE for IP LDK-300E-. PSU : 350W, 250W-. PSU-D : 320W-. Universal Slot : 9 EA
-. Digital KTU : KD/E, LKD, LDP-7000 Series DSS, Phone Box-. SLT, Fax, Modem-. Wireless Terminal GDC-330H,335H,345H
Terminal
CO/Extension Boards-. LCOB : Analog CO. Interface B/D (4 ports)-. PRIB : ISDN PRI Board (30 channels) -. BRIB/BRIBE : ISDN BRI Board (8 channels)-. STIB/STIBE : ISDN S/T Interface (8 channels) -. DTIB : Digital KTU Interface B/D(12,24 ports) -. SLIB24/48 : Single Line Tel Interface B/D(6 ports)-. DSIB : 6 Digital KTU and 6 SLT Interface B/D(12 ports)-. SLIBII : Single Line Tel Interface B/D(12 ports)-. WTIB : DECT Interface B/D (4Cell +Opt 4Cell)-. WTIU : DECT option B/D (4 Cell )-. SLIB2E : 12 port SLT Interface B/D-. VOIB/VOIBE : VOIP Interface B/D(8 chs/24 chs)-. CLCOB4/8 : 4/8 ports CO Interface B/D with CID function-. VMIB/VMIBE : Voice Mail I/F B/D (8 chs, max.10Hr)
Optional boards
-. DTRU : DTMF Receiver Unit(2 chs)-. CMU : Call Metering Unit(16KHz,12PR,50PR)-. RGU5 : Ring Generator Unit(External)-. PFTU : Power Failure Transfer Unit (6 circuits)-. DTRUII : DTMF Receiver Unit (4 chs) -. CPTU A/B : Call Progress Tone detection Unit (2 chs)-. MODU : Modem Unit (33.6kbps)-. RGU : Ring Generator Unit ( Int 25Hz)-. DTRU4 : DTMF receiver unit ( 4 chs)-. RAU : Relay Alarm Unit-. CPTU4 : Call Progress Tone detection Unit (4 chs)-. CMU4 : Call Metering Unit (4 chs)-. VOIU/VOIUE : VOIP Interface Unit (2 chs/12 chs)-. RPTU : RePeaTer unit for DKTU-. SDMU32/SDMU_A : SDRAM module-. CIDU4/8 : Caller ID unit(4/8 chs)-DTMF/FSK Type-. VCEU/VCEUE : Voice Channel Expansion Unit (4 chs)-. FMEU2 : Flash Memory Expansion Unit (5 hours)
System Components
2/16
1. System Introduction
KSU
-. KSU : Key Service Unit-. MPB : Main Processor Board-. PSU : 120W-. PSU-D : 320W-. Universal Slot : 6 EA
CO/Extension Boards
All kinds of CO & Extension card used in LDK-300
[LDK-100 Only]
BRIBE : 2 Basic Rate Interface
BRIUE : 2 Basic Rate Interface
NPRIB : 1 Primary Rate Interface
Optional boards
All kinds of option boards used in LDK-300
[LDK-100 Only]
SIU :1 Serial port
LANU : 10 Base-T Ethernet port
SMEMU : 2Mbytes SRAM Expansion
DMEMU : Software Download
PLLU : for ISDN Board
LDK-100
-. Digital KTU : KD/E, LKD, LDP-7000 Series DSS, Phone Box-. SLT, Fax, Modem, TAD-. Wireless Terminal: GDC-330H,335H,345H
Terminal
System Components
3/16
1. System Introduction
-. Medium / Large Size Digital KTS -. Maximum Capacity
So(STIB)
DKTU(DTIB24)
SLT(SLIB II)
PRI(PRIB)
BRI(BRIB)
LCO(LCOB8)
1st KSU 48(2) 48(4)
1st KSU+2nd 96(4) 96(8)
1st KSU 56(7) 96(4) 96(8) 120(4) 56(7) 64(8)
1st KSU+2nd 112(14) 192(8) 192(16) 180(6) 112(14) 128(16)
1st KSU+2nd+3rd 152(19) 288(12) 288(24) 180(6) 152(19) 192(24)
1st KSU+2nd+3rd+4th 384(16) 384(32) 256(32)
1st KSU+2nd+3rd+4th+5th 396(17) 480(40) 320(40)
1st KSU+2nd+3rd+4th+5th+6th 396(17) 576(48) 384(48)
Max. Port (Number of Boards)
Extension Network Side
152(19) 180(6) 152(19)
40(5) 40(2) 40(5) 40(5)
LDK-300E
SYSTEM KSU
LDK-100
LDK-300
-. VMIB
LDK-100 : Max. 16 Channels, 20 Hours(2)
LDK-300/300E : Max. 24 Channels, 30 Hours(3)
-. WTIB
LDK-100 : Max 16 Cells(2)
LDK-300/300E : Max 24 Cells(3)
System Max. Call Capacity
4/16
1. System Introduction
LDK-100 LDK-300 LDK-300E
1st KSU 144 144
2nd KSU 144 144
3rd KSU 96 96
2 3 6
2(MPBE:1, SIU:1) 4(MPB:2, MISB:2) 4(MPB:2, MISB:2)
2(MPBE:1, MISB:1) 3(RAU:2, MISB:1) 3(RAU:2, MISB:1)
6(MPBE:2, MISB:4) 7(RAU:3, MISB:4) 7(RAU:3, MISB:4)
3(MPBE:1, MISB:2) 3(MPB:1, MISB:2) 3(LMUE:1, MISB:2)
32 80 112(Master:80, Expansion:32)
40 90(30/KSU) 180(30/KSU)
5 15 15
External 3(MPBE:1, MISB:2) 3(MPB:1, MISB:2) 3(LMUE:1, MISB:2)
Internal 15 35 35
1500(24Digits) 3000(24Digits) 5000(24Digits)
100(24Digits) Per Station 100(24Digits) Per Station 100(24Digits) Per Station
10 10 10
1 1 1
3 7 7
2000 5000 10000
24 72 72
15 48 48
CapacityDescription
Time Slots144
Paging Zone
KSU
Serial Port(RS-232C)
Alarm/Door Bell Input
External Control Contact
Music Source Inputs
DTMF Receivers
Power Fail Circuit
Intercom Group
System Speed Dial
Station Speed Dial
Last Number Redial
Save Number Redial
DSS/DLS Console
SMDR
CO Line Group
Hunt/UCD Group
System Resources & Capacity
5/16
2. New Board Description
New Board/Unit
Board Unit
CLCOB 4/8
VOIBE
VMIBE / AAIBE
MPBE
LMUE
PSU-D
CIDU 4/8
VOIUE
VCEUE
PMUE
6/16
2. New Board Description
Description •CLCOB4 provides 4 Loop start CO line interface.•CLCOB8 provides 8 Loop start CO line interface.•CLCOB4/8 can be installed on the universal slot No.1-9 of any KSU.•Maximum 200 analog lines limit Analog CO interface ports.•Pulse Dial function is not applicable in CLCOB8.•CLCOB4/8 are implemented to accommodate CIDU4/8 option board.•Add-on boards : -.CLCOB4 : DTRU4, CPTU4-C, CIDU4(CID + CMU-50PR)-.CLCOB8 : DTRU4, CPTU4-C, CIDU8(CIDU + CMU-50PR)
Switching Functions
LED Function RemarkLED1 The status of line 1, ON: in use, Green CLCOB4/8LED2 The status of line 1, ON: in use, Green CLCOB4/8LED3 The status of line 1, ON: in use, Green CLCOB4/8LED4 The status of line 1, ON: in use, Green CLCOB4/8LED5 The status of line 1, ON: in use, Green CLCOB8LED6 The status of line 1, ON: in use, Green CLCOB8LED7 The status of line 1, ON: in use, Green CLCOB8LED8 The status of line 1, ON: in use, Green CLCOB8
LED Indications-CLCOB4/8
SW Function RemarkMode selection switch ON : Country mode OFF : CTR21 modeUpper Side – Normal Operation(short loop)Lower – Service Position(long loop)
SW1 1), 2)
SW2 3), 4)
CLCOB4/8
7/16
2. New Board Description
Description •There are two types of CIDU4/8, FSK-CIDU4/8 and DTMF-CIDU4/8.•FSK/DTMF CIDU4/8 detects Caller ID signal that are supplied from the CO line interface.•FSK/DTMF CIDU4/8 interface contains Microprocessor, CID Unit in the Memory, Call Metering Unit (CMU-50PR). •FSK/DTMF CIDU4/8 is used as an Option Board in CLCOB4/8 and cannot be used alone.•Only when CIDU4/8 is inserted to CLOB4/8, the MPB recognizes CLOB4/8 board as IPP board.•FSK-CIDU4/8 enables CID function in case of On-hook(Type I) and Off-hook(Type II).•DTMF-CIDU4/8 enables only for On-hook(Type I).
Switching Function
LED IndicationsLED Function RemarkLED1 Flickering : CIDU in use (Green)LED2 Reserved
Switch Function RemarkSW1 CIDU Reset button
CIDU4/8
8/16
2. New Board Description
Description •The VOIBE/VOIUE card can be installed in LDK-300 and LDK-100. •Its main job is to provide the Ethernet interface for S/W applications and VOIP feature with optional VOIUE daughter. •VOIB is installed on the universal slot No. 1-9 of KSU except the slot No. 9 of 1st KSU.•The number of ports are expanded to 24 channel comparing with the existing VOIB.•VOIBE has twelve(12) ports basically and VOIUE has additional twelve(12) ports.
Switching Functions
LED Indications
VOIBE/VOIUE
Switch Number Functions RemarkSW 1 Hardware Reset Switch for CPU(S32500C)SW 2 Watch dog enable Switch Default : Off
Pole 1 ReservedPole 2 Boot Mode(Off), Application Mode(On) Default : OnPole 3 Reserved
Pole 4 Reserved
SW 4
LED Number Functions RemarkLD 1 to LD 4 Channel Status LED (ON : Busy, Off : Idle)
LD5 VOIBE DSP Status (ON : Busy, Off: idle)LD6 VOIUE DSP Status (ON : Busy, Off: idle)
LD7 to LD8 ReservedLD9 Operation
LD12,LD16Collision Status LED(ON : Collision, OFF : Normal operation)
LD11,LD15Full-Duplex Status LED(ON : Half-Duplex, OFF : Full-Duplex)
LD13,LD17Speed Status LED(ON : 100Mbps operation, OFF : 10Mbps)
Seen inMJ1, MJ2
LD10,LD14Link Status LED(ON : Link OK, OFF : No Link)
Seen inMJ1, MJ2
9/16
2. New Board Description
Description •VMIBE/AAIBE provides system announcement, ACD/UCD announcement, and User Greeting.•Voice quality has been improved comparing with VMIB/VMIB2/AAIB.•Enhanced features are implemented (Message forwarding and message rewinding while listening message)•Add-on boards: -. VMIBE : VCEUE, FMEU2 -. AAIBE : VCEUE.
Switching Functions
LED Indications
Item Channel System Greeting User Greeting Maximum Capacity
Basic : 4 ch Basic : 300 min
Option : 4 ch Option : 300 min
Basic : 4 ch
Option : 4 ch
24 ch, 3boards / System
3 min 20 sec 8 ch, 1board / System
VMIBE 30 min
AAIBE 10 min
Switch Function Remark
SW1 SRAM back-up when power interruption or failure Should be ON
SW3 JTAG reset enable for DSP Don’t care. Development purpose
SW4 VMIBE reset button Development purpose
ON OFFLED1 The status of channel 1 In use IdleLED2 The status of channel 2 In use IdleLED3 The status of channel 3 In use IdleLED4 The status of channel 4 In use IdleLED5 The status of channel 5 In use IdleLED6 The status of channel 6 In use IdleLED7 The status of channel 7 In use IdleLED8 The status of channel 8 In use IdleLED9 The status of CPU running In use Idle Only VMIBE
No DescriptionStatus
Remark
VMIBE/AAIBE
10/16
2. New Board Description
Description •VCEUE: Provides additional 4 VMIBE channels. •FMEU2: Provides additional 5 hours recording time of VMIB2 and VMIBE.•The voice recording capacity of VMIBE and AAIBE
1. VMIBE
5 hours (System greeting : 30 minutes, User greeting : 4 hours and 30 minutes)
2. VMIBE with FMEU2
10 hours (System greeting : 30 minutes, User greeting : 9 hours and 30
minutes)
3. AAIBE
13 minutes (System greeting : 10 minutes, User greeting : 3 minutes)
Compatibility of VMIB/VMIB2/VMIBE with optional boards/ AAIBE
VCEUE/FMEU2
11/16
2. New Board Description
Description •The 32MB SDRAM is used for software downloading and additional features.•Before installing the MPBE, you must install the PMUE.•The MPBE must be used for expanding from LDK-300 system(300 ports) to LDK-300 Expansion system(600 ports) and installed on the MPB slot of the 1st KSU.•To operate LDK-300 Expansion system, connect the CN 1 of MPBE to the CN1 of LMUE with Link cable attaching ferrite core.•MPBE doesn’t have one external page port and one external MOH port comparing with
MPB•The LMUE has one external page port and one external MOH port.
•Add-on Boards: PMUE, MODU
Description •The PMUE has a program for system control, administration, and call processing. •The PMUE is mounted on the MPBE. •The PMUE has 8M bytes of four 70ns 16Mbit flash ROMs which is available of software downloading by BDM(Board Debug Module) tool, ISDN line or LAN port.
MPBE/PMUE
12/16
2. New Board Description
Switch Function OFF ON
1 Administration Programming Access Disable Enable
2 CTS (Clear to Send) of RS-232C Enable Disable
3 Command/Event Trace (The purpose of testing software) Enable Disable
4 Not used - -
5 SMDI (Simplified Message Desk Control –Voice Mail ) SMDI ON SMDI OFF
6 Not used - -
7 Power up status trace of board Enable Disable
8 Database default on power up Disable Enable
Various switches and connector Functions
Function of SW3
Switch/Connector Functions Remark
SW1 System Reset button
SW2 Memory backup switch Database back-up
CN1 Connection between Master system and Expansion system For expansion
CN2 and CN3 MODU connection
CN4 and CN5 RS-232C Serial Interface System Access
CN6 BDM connection For Debug Mode
CN7 Card Edge connection
CN8 JTAG port for CPLD For Programming
CN9 and CN10 PMUE connection
LED IndicationsLED No Status
LED1 ON - PLL circuit activation by external synchronous clock of ISDN board
(Red) OFF - PLL circuit activation by internal clock
LED2 Not used
LED3 Timer, Flashing every 100msec
LED4 Dial Processing, Flashing every 100msec
LED5 SLT Ring Processing, Flashing every 200msec
LED6 LCD active updating, Flashing every 300msec
LED7 Call Event Processing
LED8 RS-232C Tasking
LED9 Interrupt Processing
LED10 Collision detection for Ethernet port
LED11 Data transmission for Ethernet port
LED12 Data reception for Ethernet port
LED13 Data link for Ethernet port
MPBE/PMUE
13/16
2. New Board Description
Switch /Connector
Function Remark
CN1Connection between Master system andExpansion system
For expansion
PJ1(RED)PJ2(BLUE)
External paging and MOH connection
Description •The LMUE is used to connect master system to expansion system for IP LDK-300E•The LMUE has one external page port and one external MOH port.•The LMUE is installed on the MPB slot of the 4th KSU.•To operate LDK-300 Expansion system, connect the CN 1 of MPBE
to CN 1 of LMUE by Link Cable having ferrite core.
Switches and connectors Function
LMUE
14/16
2. New Board DescriptionLMUE
15/16
2. New Board Description
PSU-D SpecificationItem Specification
DC Voltage Input -48(-42 ~ -60) Volt DCDC Power 320 WDC Input Fuse 12.5 amp @ 48 Volt DCDC Output Voltage +5, -5, +30 Volt DC
Power Supply CapacityPSU +5V -5V +30V Battery Back Up Remark
PSU 10A 1.5A 8.4A 1A / 27.3V 350WPSU3 5A 1A 7A 0.5A / 27.3V 250WPSU-D 10A 1.5A 7.5A - 320W
Description •LDK-300 PSU-D is installed on the left first and second slot of the mother board.•Two PSU-D can be inserted•In case two PSU-D are inserted, the power is provided by the method of load sharing.•If one is failed, another one supplies the power with the system.
PSU-D
16/16
Thank youThank you