19dcon106

Upload: deepak-kr-gupta

Post on 28-Feb-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/25/2019 19DCON106

    1/1

    11 cm 6 6 11 cm 11 cm

    Detail at - X

    51530151010

    Gabion Wire

    Coiled Device for preparing coils

    peg distance 2.10 m

    Length for Wire Cutting 4.20 m

    Device for uncoiling from

    supplied coil

    Coil 1

    Coil 2

    supplied

    coilcut

    here

    two turns

    two

    turns

    two turns

    with die & pipe

    combine wireknots withsuspender

    Details of Gabion WireGauge 12 SWG, 2.64 mm

    2.10 2.10 4.20 3.9018

    handrail cables

    suspenders

    fence nettingtotal 3.90 kg per m

    span for both sides

    stee wa waydeck

    fixation cables

    cross beam

    walkway

    cables

    40 60

    25 40

    Date : Nov. 05, 2001 Drawing No. 19Dcon106

    Construction Drawing:

    Bridge Name:

    No: Span:

    HMG / Ministry of Local Development

    DoLIDAR / Short SpanTrail Bridge Standard

    Walkway Fitting for

    106 cm Walkway Width

    X

    X

    Bulldog Grip

    2 Walkway

    Cables at

    each side

    Cross Section of Walkway

    Produced by Swiss Association for International Cooperation, in partnership with His Majestys Government of Nepal, funded and supported by the Swiss Government (SDC Nepal).Nepal

    Bulldog Grip

    2 Walkway Cables

    1 Walkway Cable

    Handrail Cable

    Fixation Cable

    Bridge Axis Line

    Start fittingcrossbeam & steeldeck End of walkway fitting

    Outer row of steeldeck

    Standard panel

    Standard panel

    Half panel

    Standard panel

    Standard panel

    Standard panel

    Standard panel

    Center row

    Special panel

    Standard panel Special panel

    Steeldeck to be fixed

    in staggered way

    Bulldog Grip

    Bulldog Grip

    Bulldog Grip

    Outer row of steeldeck

    Special panel

    106 cm

    2 walkway cables 4 walkway cables

    1 Walkway Cable

    at each side

    106 cm

    fixation cablefixation cable

    Fixation Cable

    100

    165

    Required Nos of Crossbeams :

    = Span in[m]

    Required Nos of Steeldeck Pannels :Standard pannelsHalf pannelSpecial pannels

    = 1.5 x (Span - 1.20) in[m]

    = 1 pc= 3 pcs

    17