19938 - venturo

56

Upload: others

Post on 26-Dec-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 19938 - Venturo
Page 2: 19938 - Venturo
Page 3: 19938 - Venturo

19938-

-

7-24-01TABLE OF CONTENTS

ET25KSUPERCEDES

TITLE DATE SECTION

TABLE OF CONTENTSET25K INSTRUCTION MANUAL

SECTION 100 DESCRIPTION & SPECIFICATIONS19398a ET25K SPECIFICATIONS & OPERATING FEATURES19398b ET25K SPECIFICATIONS & OPERATING FEATURES19391 INSTALLATION DIMENSIONS - ET25KI19233 CAPACITY CHART - ET/HT25K(X) 10-16-20 FT17089 TYPICAL REINFORCEMENT FOR MOUNTING CRANE ON TOP OF SERVICE BODYI23960 INSTALLATION DIMENSIONS - 23960 MANUAL OUTRIGGER FOLD AWAY TYPEI23961 INSTALLATION DIMENSIONS - 23961 MANUAL OUTRIGGER SIDE BRACKETI23962 INSTALLATION DRAWING - 23962 OUTRIGGER SERIES22458 INSTALLATION DIMENSIONS - 23962-P-II & 23962-PM-II MANUAL OUTRIGGER22459 INSTALLATION DIMENSIONS - 23962-CD-II CRANKDOWN OUTRIGGERS22429 INSTALLATION DIMENSIONS - 23962-PH-II HYDRAULIC OUTRIGGERS14510 INSTALLATION DRAWING - 17350 MOUNTING PEDESTAL19411 INSTALLATION DRAWING - 17350 MOUNTING PEDESTAL

SECTION 150 SAFETY15394 VEHICLE & CRANE ELECTRICAL HAZARD INFORMATION850711 SAFETY & HAZARDS - GENERAL

SECTION 200 INSTALLATION711105 CABLE & BATTERY REQUIREMENTS - ET AND HT CRANES15660 BATTERY CABLE INSTALLATION DRAWINGI25600 INSTALLATION DRAWING - 25600 WIRING KITI24600 ET25K(X) ELECTRICAL INSTALLATIONI25618 INSTALLATION DRAWING - PENDANT CORD SUPPORT711006 WIRE ROPE SPECIFICATIONS20420 INSTALLATION DRAWING - 20381 ADJUSTABLE BOOM REST - ET/HT25 HT40/50

SECTION 300 MAINTENANCE & SERVICE16510 ET25K(X) LUBRICATION CHART780906 MINIMUM VOLTAGE TEST24499-1 ET25K(X) WINCH GEARBOX ASSEMBLY & SERVICE INSTRUCTIONS24499-8 ET25K(X) WINCH GEARBOX ASSEMBLY & SERVICE INSTRUCTIONS24499-2 ET25K(X) ROTATION GEARBOX ASSEMBLY & SERVICE INSTRUCTIONS24499-9 ET25K(X) ROTATION GEARBOX ASSEMBLY & SERVICE INSTRUCTIONS780607 ET25K(X) MOTOR INSTALLATION

SECTION 400 REPLACEMENT PARTS19939 ET25K REPLACEMENT PARTS DRAWING19936 ET25K REPLACEMENT PARTS LIST19929 19920 (10-20 FT BOOM ASSEMBLY) REPLACEMENT PARTS20197-2 19197-2 ANTI-TWO-BLOCK SYSTEM REPLACEMENT PARTS19438 ET25K WIRING DIAGRAM WITH ANTI-TWO-BLOCK17533 BATTERY & MOTOR CABLE DIAGRAM16741 HYDRAULIC SYSTEM SCHEMATIC - ET25K19368 16780 SWIVEL TERMINAL ASSEMBLY REPLACEMENT PARTS20150 REPLACEMENT PARTS - 3 FUNCTION PENDANT CONTROL19791 REPLACEMENT PARTS - 3 FUNCTION CRANESI17530 17530 WINCH POWER UNIT REPLACEMENT PARTS DRAWING900617 17530 WINCH POWER UNIT REPLACEMENT PARTS LIST17472 17471 ROTATION POWER UNIT REPLACEMENT PARTS DRAWING900319 17471 ROTATION POWER UNIT REPLACEMENT PARTS LIST18021 18021 HYDRAULIC POWER UNIT ASSEMBLY22434 REPLACEMENT PARTS - 23962-P-II MANUAL OUTRIGGER22441 REPLACEMENT PARTS - 23962-CD-II CRANKDOWN OUTRIGGER23962-2 INSTALLATION & REPLACEMENT PARTS - STUB OUTRIGGER

CINCINNATI, OHIOMFG., INC.

Page 4: 19938 - Venturo
Page 5: 19938 - Venturo

CINCINNATI, OHIOMFG., INC.

SPECIFICATIONS AND OPERATING FEATURESET25K-10/20

SPECIFICATIONS12 VOLT BATTERY OPERATED

25,000 FT-LBS OVERTURNING MOMENT (Or as limited by truck stability)

MOMENT OVERLOAD ALARM SYSTEM

WINCH - 2500 LBS SINGLE LINE CAPACITYWith Automatic Load Brake; With 80 ft of 5/16" Wire Rope

ELECTRIC HYDRAULIC BOOM ELEVATION

CONTINUOUS POWER ROTATION - With Coast Limiting Brake

REMOTE CONTROL PENDANT25 ft Straight Cord with Three Environmentally Sealed Toggle Switches Protected by a Guard

MASTER DISCONNECT SWITCH

OUTRIGGERS AVAILABLESide Bracket Type Outriggers

Fold Away Type Outriggers

Pullout Type Outrigger System

OVERLOAD ALARM SYSTEMTHIS CRANE IS EQUIPPED WITH AN OVERLOAD ALARM SYSTEM.

A. Overload alarm horn sounds if rated load is exceeded at any reach.

B. If alarm sounds, RAISE Boom or LOWER Winch to remove overload.

C. Always RAISE Boom slightly before lifting load - Warning system INOPERATIVE when cylinder iscompletely bottomed.

D. Alarm can be tested by tying down Boom with winch cable and operating Boom UP or by raising Boomagainst UP limit stop.

NOTICE: ANSI Standards provide that rated load at any reach must not exceed 85% of the load that willoverturn vehicle and must not exceed the load governed by structural and hydraulic competence. This alarmsystem has been installed as a safety feature to protect both the equipment and the operator.

WARRANTY VOID IF ALARM IS DISCONNECTED, READJUSTED, OR TAMPERED WITH.

TELESCOPIC BOOM ET25K - 10/20 FT

BOOM HYD ELEV. -8° TO 75°

BOOM MANUAL EXT 10 - 20 FT

1050 LBS @20 FT REACH

CAPACITY5000 LBS @

3 TO 5 FT REACH

PERFORMANCE SPECS I19233DRAWING NO.

19398aC120

10-28-97

4-10-00BINSTALLATION DWG

ET25K-10/20

Page 6: 19938 - Venturo

CINCINNATI, OHIOMFG., INC.

19398bC120

11-24-97A

4-10-00BINSTALLATION DWG

ET25K-10/20

CONTROL PRIORITY SYSTEMAs a built in safety feature the operator can perform only one major and one minor function at any one time.Major functions are rotation, winching up of a load, and elevating the boom. Minor functions are winchingdown, and lowering boom.

A. ORDER OF PRIORITIES

WINCH UP - First priority

BOOM UP - Second priority

ROTATION - Third priority

B. BOOM DOWN and WINCH DOWN can be operated with any other function.

CABLE DRUM AND SHEAVE DIAMETERSThe drum on the ET20K/25K is 5-1/4" in diameter which is 18 times the 5/16" wire rope diameter as requiredby ANSI B30.15 Hydraulic Crane Standards. The cable sheaves are either 16 or 18 times the cable diameterwhich likewise conforms.

MISCELLANEOUSA. WINCH BRAKE

Exclusive with the VENTURO Winch is the automatic thrust brake which adjusts to the load when lowering("winch down") and offers no resistance when raising ("winch up").

B. ROTATION BRAKERotation Motor brake limits Rotation coast after switch is turned off.

C. CAPACITY INDICATORSelect boom reach and angle allowable for load by using capacity indicator arrow and chart on either sideof boom.

D. BATTERY HOOKUPA parallel auxiliary battery should be installed near the crane as shown on Dwg. I24600 under"RECOMMENDED INSTALLATION". The parallel auxiliary battery minimum rating should be 450 ColdCranking Amps (at 0° F) and 100 reserve capacity, or 78 plates and 70 amp hours.

Page 7: 19938 - Venturo
Page 8: 19938 - Venturo
Page 9: 19938 - Venturo

1708

9C

100

6-24

-98A

11-2

-98B

INS

TA

LLA

TIO

N D

RA

WIN

G

ET

25K

(X)

SU

PE

RC

ED

ES

TIT

LED

AT

ES

EC

TIO

N

CIN

CIN

NA

TI,

OH

IOM

AN

UF

AC

TU

RIN

G, I

NC

.

Page 10: 19938 - Venturo

I239

60C

100

7-27

-83B

4-29

-98C

INS

TA

LLA

TIO

N D

RA

WIN

G

ET

10K

(X),

ET

25K

(X),

HT

25K

XS

UP

ER

CE

DE

S

TIT

LED

AT

ES

EC

TIO

N

CIN

CIN

NA

TI,

OH

IOM

AN

UF

AC

TU

RIN

G, I

NC

.

.O

NT

RA

PN

OIT

PIR

CS

ED

'A'

'B'

'C'

'D'

1-0

69

32

TR

OH

SR

EG

GIR

TU

O"

2/1

02

"2/

18

2"

12

"4/

17

2-0

69

32

GN

OL

RE

GGI

RT

UO

"2/

18

2"

2/1

44

"9

2"

2/1

01

Page 11: 19938 - Venturo

I239

61C

100

7-27

-83C

4-29

-98D

INS

TA

LLA

TIO

N D

RA

WIN

G

ET

10K

(X),

ET

25K

(X),

HT

25K

XS

UP

ER

CE

DE

S

TIT

LED

AT

ES

EC

TIO

N

CIN

CIN

NA

TI,

OH

IOM

AN

UF

AC

TU

RIN

G, I

NC

.

Page 12: 19938 - Venturo

I239

62C

120

4-27

-92D

4-12

-99E

INS

TA

LLA

TIO

N D

RA

WIN

G

ET

25K

(X),

HT

25K

(X),

HT

40/5

0KX

SU

PE

RC

ED

ES

TIT

LED

AT

ES

EC

TIO

N

CIN

CIN

NA

TI,

OH

IOM

AN

UF

AC

TU

RIN

G, I

NC

.

OU

TR

IGG

ER

IN/O

UT

UP

/DO

WN

DU

TY

US

ED

ON

2396

2-P

MA

NU

AL

MA

NU

AL

ST

AN

DA

RD

ET

/HT

25K

(X)

2396

2-P

MM

AN

UA

LM

AN

UA

LH

EA

VY

HT

40/5

0KX

2396

2-C

DM

AN

UA

LC

RA

NK

-DO

WN

HE

AV

YE

T/H

T25

K(X

), H

T40

/50K

X23

962-

PH

MA

NU

AL

HY

DR

AU

LIC

HE

AV

YH

T25

K(X

), H

T40

/50K

X23

962-

PH

XH

YD

RA

ULI

CH

YD

RA

ULI

CH

EA

VY

HT

25K

(X),

HT

40/5

0KX

2396

2-P

HE

MA

NU

AL

ELE

CT

RIC

/HY

DR

AU

LIC

HE

AV

YE

T25

K(X

)23

962-

PH

XE

ELE

CT

RIC

/HY

DR

AU

LIC

ELE

CT

RIC

/HY

DR

AU

LIC

HE

AV

YE

T25

K(X

)

Page 13: 19938 - Venturo
Page 14: 19938 - Venturo
Page 15: 19938 - Venturo
Page 16: 19938 - Venturo

1451

0C

100

11-2

-98J

4-8-

99K

INS

TA

LLA

TIO

N D

RA

WIN

G

ET

25K

(X),

HT

25K

(X)

SU

PE

RC

ED

ES

TIT

LED

AT

ES

EC

TIO

N

CIN

CIN

NA

TI,

OH

IOM

AN

UF

AC

TU

RIN

G, I

NC

.

Page 17: 19938 - Venturo
Page 18: 19938 - Venturo

15394C150

5-13-97G

5-15-02HINSTALLATION DWG

ET & HT CRANE SERIESSUPERCEDES

TITLE DATE SECTION

VEHICLE & CRANE MOUNTED ELECTRICAL HAZARD SIGNAPPLICATION & INFORMATION

ET & HT CRANE SERIES

SIGN NO. 15393A DISPLAYS THE INTERNATIONAL SYMBOL FORELECTRICITY AND WARNS OF DANGER FROM ANELECTRICALLY CHARGED VEHICLE, CRANE, OR LOAD. FOURARE RECOMMENDED (ONE FOR EACH SIDE AND ONE FOREACH END OF VEHICLE) TO BE APPLIED IN LOCATIONS WHICHARE READILY VISIBLE TO GROUND PERSONNEL.

SIGN NO. 15401 PROVIDES ADDITIONAL WARNING OF LEGALREQUIREMENTS WHEN OPERATING NEAR HIGH VOLTAGELINES. THIS SIGN IS PLACED ON THE CONTROL PENDANTSIDE OF BOOM.

REQUIRED MINIMUM CLEARANCES REFERRED TO ON SIGN NO. 15401

REQUIRED CLEARANCES FROM OVERHEAD HIGH-VOLTAGE LINES

NOMINAL VOLTAGE (kV) MINIMUM REQUIRED(PHASE TO PHASE) CLEARANCE (FEET) *

0 - 50 10over 50 - 200 15over 200 - 350 20over 350 - 500 25over 500 - 750 35over 750 - 1000 45

REQUIRED CLEARANCES FROM ENERGIZED HIGH-VOLTAGE CONDUCTORS(WHILE IN TRANSIT)

NOMINAL VOLTAGE (kV) MINIMUM REQUIRED(PHASE TO PHASE) CLEARANCE (FEET) *

0 - 0.75 4over 0.75 - 50 6over 50 - 345 10over 345 - 750 16over 750 - 1000 20

* NOTE: ENVIRONMENTAL CONDITIONS SUCH AS FOG, SMOKE, OR PRECIPITATION MAY REQUIREINCREASED CLEARANCES

CINCINNATI, OHIOMFG., INC.

Page 19: 19938 - Venturo

CRANE SAFETY AND HAZARDSET5500MPB/R, ET6KMPB/R, ET8100R, ET10K(X), ET25K(X)

CAUTIONS1. INSPECT VEHICLE AND CRANE, INCLUDING OPERATION, PRIOR TO USE DAILY.2. DO NOT USE THIS EQUIPMENT EXCEPT ON SOLID, LEVEL SURFACE WITH CRANE MOUNTED ON

FACTORY-RECOMMENDED TRUCK.3. BEFORE OPERATING THE CRANE, REFER TO MAXIMUM LOAD (CAPACITY) CHART ON CRANE FOR

OPERATING (LOAD) LIMITATIONS.4. DO NOT OPERATE, WALK, OR STAND BENEATH BOOM OR A SUSPENDED LOAD.5. ATTACH PENDANT CORD SUPPORT SNAP TO ATTACHMENT POINT BEFORE PLUGGING IN

PENDANT.6. UNPLUG PENDANT AND SHUT OFF MASTER DISCONNECT SWITCH WHEN CRANE NOT IN USE.7. FOR TRAVEL, BOOM MUST BE IN STOWED POSITION.

DANGER• THIS CRANE IS NOT A PASSENGER LIFT• IT IS NOT DESIGNED OR INTENDED TO BE USED TO LIFT, SUPPORT, OR OTHERWISE TRANSPORT

PERSONNEL.

YOU MUST NOT OPERATE THIS CRANE UNLESS1. YOU HAVE BEEN TRAINED IN THE SAFE OPERATION OF THIS CRANE

AND2. YOU KNOW AND FOLLOW THE SAFETY AND OPERATING RECOMMENDATIONS CONTAINED IN THE

MANUFACTURER'S MANUALS, YOUR EMPLOYER'S WORK RULES, AND APPLICABLE GOVERNMENTREGULATIONS. AN UNTRAINED OPERATOR SUBJECTS HIMSELF AND OTHERS TO DEATH ORSERIOUS INJURY.

ELECTROCUTION HAZARD• THIS MACHINE IS NOT INSULATED.• MAINTAIN SAFE CLEARANCES FROM ELECTRICAL LINES AND APPARATUS.• YOU MUST ALLOW FOR BOOM SWAY, ROCK OR SAG, AND ELECTRICAL LINE AND LOADLINE

SWAYING.• THIS LIFTING DEVICE DOES NOT PROVIDE PROTECTION FROM CONTACT WITH OR PROXIMITY TO

AN ELECTRICALLY CHARGED CONDUCTOR.• YOU MUST MAINTAIN A CLEARANCE OF AT LEAST 10 FEET BETWEEN ANY PART OF THE CRANE,

LOADLINE, OR LOAD, AND ANY ELECTRICAL LINE OR APPARATUS CARRYING UP TO 50,000 VOLTS.ADDITIONAL CLEARANCE IS REQUIRED FOR VOLTAGES IN EXCESS OF 50,000 VOLTS. REFER TODRAWING 15394 FOR ADDITIONAL INFORMATION.

• DEATH OR SERIOUS INJURY WILL RESULT FROM CONTACT OR INADEQUATE CLEARANCE.

850711C150

5-13-97E

10-14-97FINSTALLATION DWG

ET5500MPB-ET25KXSUPERCEDES

TITLE DATE SECTION

CINCINNATI, OHIOMFG., INC.

Page 20: 19938 - Venturo

TITLE SECTION

711105

IMPORTANTADEQUATE WIRING IMPERATIVE FOR PROPER OPERATION

1. PROPER GROUND PATH - SEE DWG 15660

2. CURRENT DRAW IS SEVERAL HUNDRED AMPERES -ADEQUATE WIRE SIZE AND BATTERY CAPACITY IS ABSOLUTELYESSENTIAL (SEE CHART BELOW.)

* INCLUDES GROUND CABLE

** CCA=COLD CRANKING AMPS AT 0' F.THE CCA RATING IS A MEASURE OF THE ABILITY OF THE BATTERY TO DELIVER A HIGH CURRENT FOR A SHORT PERIOD OF TIME.

*** RC=RESERVE CAPACITY IN MINUTES AT 25 AMPS AND 80' F.THE RC RATING IS A MEASURE OF THE PERIOD OF TIME THE BATTERY CAN SUPPLY A GIVEN CURRENT WITHOUT RECHARGING.

MINIMUM WIRE GAUGE AND BATTERY SIZE

MODEL TOTAL LENGTH OF CABLE (FT)* 12 VOLT BATTERY REQUIREMENTS

0-20 21-25 26-30 31-40 41-50 51-60 61-70 71-80 CCA (A)** RC (MIN)***

CE6KCT2000CT2003/4/5 #4 #4 #2 #2 #1 #0 #0 #00 350 100DT7K

ET5500MPBET5500RET6KMPB #2 #2 #1 #0 #00 NOT RECOMMENDED 450 100ET6KRET10K

ET10KX #2 #2 #1 #0 #00 NOT RECOMMENDED 550 150

ET25K SEE DRAWING I24600 FOR CABLE AND BATTERY REQUIREMENTSET25KX

CABLE & BATTERY 8-10-00R C200

CE, CT, DT, & ET 3-3-99Q

DATE

SUPERCEDESCINCINNATI, OHIOMFG., INC.

Page 21: 19938 - Venturo

1566

0

C20

0

11-7

-01D

1-15

-02E

INS

TA

LL

AT

ION

- B

AT

TE

RY

CA

BL

E

WIN

CH

& C

RA

NE

SU

PE

RC

ED

ES

TIT

LE

DA

TE

SE

CT

ION

CIN

CIN

NA

TI,

OH

IOM

AN

UF

AC

TU

RIN

G, I

NC

.

Impo

rtan

t: T

he c

rane

mus

t mak

e co

nnec

tion

with

the

nega

tive

of th

e ba

ttery

. T

o in

sure

this

,in

stal

l a #

2 ga

uge

grou

ndin

g st

rap

from

the

engi

ne to

the

truc

k fr

ame

(req

uire

d if

nega

tive

from

batte

ry is

con

nect

ed to

the

engi

ne.)

Als

o, in

stal

l a #

2 ga

uge

grou

ndin

g st

rap

from

the

cran

eba

se to

the

truc

k fr

ame,

incl

uded

with

ET

6R, E

T10

K(X

), E

T25

K, &

ET

25K

X c

rane

s.

Fai

lure

to a

ccom

plis

h th

e ab

ove

men

tione

d st

eps

may

resu

lt in

inte

rmitt

ent o

pera

tion

ofel

ectr

ic c

rane

.

Mas

ter d

isco

nnec

tsw

itch

nece

ssar

yfo

r saf

ety

(loca

tefo

r ea

sy a

cces

s)

Eng

ine

totr

uck

fram

e

Atta

ch c

able

to b

atte

ry te

rmin

alor

sta

rter

sol

enoi

d ("

hot"

sid

e)

Fus

e or

circ

uit b

reak

er (P

/N 1

9417

) rec

omm

ende

d.Lo

cate

as

clos

e to

sta

rter

or

batte

ry a

s is

pra

ctic

al.

ET

6KR

show

n

Bat

tery

*

Pow

er u

nit c

able

*

* N

ote:

See

Dw

g 71

1105

for r

ecom

men

ded

batte

ryan

d ca

ble

spec

ifica

tions

Page 22: 19938 - Venturo

I256

00C

200

8-30

-82C

6-24

-98D

INS

TA

LLA

TIO

N D

RA

WIN

G

ET

20K

, E

T25

K(X

)S

UP

ER

CE

DE

S

TIT

LED

AT

ES

EC

TIO

N

CIN

CIN

NA

TI,

OH

IOM

AN

UF

AC

TU

RIN

G, I

NC

.

Page 23: 19938 - Venturo

I246

00C

200

6-10

-83D

6-24

-98E

ELE

CT

RIC

AL

INS

TA

LLA

TIO

N

ET

20K

, E

T25

K(X

)S

UP

ER

CE

DE

S

TIT

LED

AT

ES

EC

TIO

N

CIN

CIN

NA

TI,

OH

IOM

AN

UF

AC

TU

RIN

G, I

NC

.

Page 24: 19938 - Venturo

I256

18C

200

7-13

-92B

5-26

-98C

PE

ND

AN

T C

OR

D S

UP

PO

RT

ET

& H

T C

RA

NE

SE

RIE

SS

UP

ER

CE

DE

S

TIT

LED

AT

ES

EC

TIO

N

CIN

CIN

NA

TI,

OH

IOM

AN

UF

AC

TU

RIN

G, I

NC

.

Page 25: 19938 - Venturo

TITLE SECTION

SUPERCEDES

DATE

711006WC 200

4-27-92F

10-23-97GWIRE ROPE SPECS

VENTURO WINCH & CRANE

SELECTION

The chart below shows the maximum working load and breaking strength of 7 X 19 Galva-nized AIRCRAFT Grade Wire Rope in various diameters. The breaking strength is 3-1/2times the maximum working load. Do not use wire rope with a Maximum Working Load ratingless than the single line capacity of the crane. Use of wire rope diameter larger than the sizefurnished with the crane will reduce the fatigue life of the wire rope.

WIRE ROPE DIAMETER MAXIMUM WORKING LOAD BREAKING STRENGTH

1/8" 570 lbs 2000 lbs

5/32" 800 lbs 2800 lbs

3/16" 1200 lbs 4200 lbs

7/32" 1600 lbs 5600 lbs

1/4" 2000 lbs 7000 lbs

5/16" 2800 lbs 9800 lbs

3/8" 4114 lbs 14400 lbs

CINCINNATI, OHIOMFG., INC.

INSTALLATION

1. Unwind coil of rope by rolling it along floor. This will prevent kinking.

2. Most VENTURO Cranes are provided with a slot in the winch drum side plate for attaching theend of the wire rope with a stop collar. A hole in the housing allows access for the end of thewire rope when inserted thru the slot.

The ET20K(X) & ET25K(X) Cranes have a clamp built into the winch drum and do not use astop collar.

3. THERE MUST ALWAYS BE AT LEAST (3) TURNS OF WIRE ROPE ON THE DRUM WHENUNDER LOAD.

Page 26: 19938 - Venturo

MIN

. HEI

GHT

= 1

8"M

AX. H

EIG

HT =

26"

(MO

UNTI

NG S

URFA

CE T

OTO

P O

F BA

SE P

AD)

18"

16"

16"

18"

WIT

H SI

NGLE

ACT

ING

ELEV

ATIO

N CY

LIND

ERM

ECHA

NICA

L DE

VICE

ISNE

EDED

TO

SEC

URE

BOO

M

UHM

W P

OLY

ETHL

YLEN

E BO

OM

PAD

S(3

PLA

CES)

CRAN

EDI

M 'X

'DA

SH N

o.20

381-

120

381-

2HT

40/5

06

1/4"

HT25

4 3/

4

INST

ALLA

TION

DRA

WIN

G20

381 A

DJ. B

OOM

REST

- ET

/HT2

5, HT

40/50

5-7-

01A

11-2

-01B

DATE

SECT

ION

SUPE

RSED

ES

TITL

E

2042

0

'X'

Page 27: 19938 - Venturo

1651

0C

300

6-1-

92C

6-24

-98D

LUB

RIC

AT

ION

CH

AR

T

ET

20K

(X),

ET

25K

(X),

ET

30K

, E

T36

KX

SU

PE

RC

ED

ES

TIT

LED

AT

ES

EC

TIO

N

CIN

CIN

NA

TI,

OH

IOM

AN

UF

AC

TU

RIN

G, I

NC

.

Page 28: 19938 - Venturo
Page 29: 19938 - Venturo

2449

9-1

C30

0

6-16

-92A

6-24

-98B

AS

SE

MB

LY &

SE

RV

ICE

IN

ST

RU

CT

ION

S

ET

20K

(X),

ET

25K

(X),

ET

30K

SU

PE

RC

ED

ES

TIT

LED

AT

ES

EC

TIO

N

CIN

CIN

NA

TI,

OH

IOM

AN

UF

AC

TU

RIN

G, I

NC

.

Page 30: 19938 - Venturo

2449

9-8

C30

0

6-15

-92A

6-24

-98B

AS

SE

MB

LY &

SE

RV

ICE

IN

ST

RU

CT

ION

S

ET

20K

(X),

ET

25K

(X),

ET

30K

, E

T36

KX

SU

PE

RC

ED

ES

TIT

LED

AT

ES

EC

TIO

N

CIN

CIN

NA

TI,

OH

IOM

AN

UF

AC

TU

RIN

G, I

NC

.

Page 31: 19938 - Venturo

2449

9-2

C30

0

6-16

-92A

6-24

-98B

AS

SE

MB

LY &

SE

RV

ICE

IN

ST

RU

CT

ION

S

ET

20K

(X),

ET

25K

(X),

ET

30K

SU

PE

RC

ED

ES

TIT

LED

AT

ES

EC

TIO

N

CIN

CIN

NA

TI,

OH

IOM

AN

UF

AC

TU

RIN

G, I

NC

.

Page 32: 19938 - Venturo

2449

9-9

C30

0

6-16

-92A

6-24

-98B

AS

SE

MB

LY &

SE

RV

ICE

IN

ST

RU

CT

ION

S

ET

20K

(X),

ET

25K

(X),

ET

30K

SU

PE

RC

ED

ES

TIT

LED

AT

ES

EC

TIO

N

CIN

CIN

NA

TI,

OH

IOM

AN

UF

AC

TU

RIN

G, I

NC

.

Page 33: 19938 - Venturo

780607C300

10-2-80B

6-24-98CINSTALLATION DRAWING

ET25K(X)SUPERCEDES

TITLE DATE SECTION

CINCINNATI, OHIOMFG., INC.

FIELD SERVICE BULLETININSTALLATION OF 16115 & 17532 MOTORS ON ROTATION & WINCH POWER UNITS

PROCEDURE:

1. REFER TO DRAWING 760302/14501 FOR REPLACEMENT PARTS

2. CHECK WORM & SHAFT SHOULDER POSITION PER DRAWING 14499-6 &READJUST SHIMS AS REQUIRED. THIS IS MANDATORY IF GEAR HEADCOMPONENT PARTS HAVE BEEN REPLACED.

3. CAREFULLY ALIGN TANG ON GEAR HEAD INPUT SHAFT WITH HOLES INFLANGE & TANG SLOT IN MOTOR WITH MOTOR MOUNTING STUDS.

4. PRESTRETCH LIP OF 00992 MOTOR SHAFT SEAL OPEN WITH FINGER TIPSAND LUBRICATE SEAL LIP WITH GEAR OIL.

5. WHEN INSTALLING MOTOR, BE CAREFUL NOT TO CATCH LIP OF SEAL ONEND OF SHAFT TANG OR SHOULDER AS SEALING LIP MAY BE DAMAGEDOR THE SPRING KNOCKED OUT OF THE SEAL.

Page 34: 19938 - Venturo

1993

9C

420

-7-25

-01

REP

LAC

EMEN

T PA

RTS

ET25

KSU

PERC

EDES

TITL

EDA

TESE

CTIO

N

SN: 7

1866

& U

P

SERV

ICE

INST

RUCT

IONS

1454

4AD

JUST

MEN

T O

FW

OR

M H

EIG

HT

AND

BAC

KLAS

H14

553

ADJU

STM

ENT

OF

WO

RM

EN

D P

LAY

CIN

CIN

NA

TI, O

HIO

MA

NU

FAC

TUR

ING

, INC

.

Page 35: 19938 - Venturo

1993

6C

420

7-24

-01

5-17

-02A

RE

PL

AC

EM

EN

T P

AR

TS

ET

25K

- 1

0/20

SU

PE

RC

ED

ES

TITL

ED

ATE

SE

CTI

ON

115

808

BE

AR

ING

- 1

1/4

" ID

x 1

5/8

" O

D x

11/

16"

LON

G2

26

39

5-2

0.5

CY

LIN

DE

R P

RE

SS

UR

E H

OS

E -

3/8"

x 2

0 1/

2"3

13

16

8-2

SLE

EV

E -

3/4

" O

D x

5/8

" ID

x 1

1/1

6" L

ON

G4

2316

9S

WIV

EL

SN

AT

CH

BLO

CK

AS

SE

MB

LY5

!HH

CS

0501

3125

-5H

EX

HE

AD

CA

P S

CR

EW

- 1/

2"-1

3 x

1 1/

4" G

RA

DE

56

13

45

9-2

AR

RO

W7

1580

9S

PA

CE

R -

3/4

" ID

x 1

1/4

" O

D x

21/

32"

LON

G8

2391

1S

HE

AV

E (I

NC

LUD

ES

ITE

MS

1, 4

3, 4

4, 8

0, &

81)

913

918

PIV

OT

PIN

, BO

OM

- 1

1/2

" O

D x

11

3/4"

10

18

70

0-2

ELE

VA

TIO

N C

YLI

ND

ER

11

13

97

8LO

WE

R B

EA

RIN

G1

22

63

61

BE

AR

ING

PLA

TE

TH

ES

E P

AR

TS

AR

E M

AT

CH

ED

SE

T A

ND

13

18

71

3W

ELD

ED

HO

US

ING

AS

SY

TY

PIC

ALL

Y N

OT

AV

AIL

AB

LE A

S P

AR

TS

.

14

14

08

4C

OU

PLI

NG

15

1992

0B

OO

M A

SS

EM

BLY

- 10

/20

FT

(CO

MP

LET

E A

SS

Y)

16

--

17

14

14

2-4

WO

RM

- S

ING

LE T

HR

EA

D R

H1

81

41

43

-4W

OR

M G

EA

R -

48T

, 4 P

ITC

H1

92

63

73

DR

UM

SH

AF

T2

02

63

65

CA

BLE

DR

UM

21

26

37

2-1

BE

AR

ING

CU

P -

LH2

22

63

72

-2B

EA

RIN

G C

UP

- R

H2

32

63

90

RE

AR

CO

VE

R24

*14

159

SH

IM -

1 1

/2"

SQ

x .

015"

, .0

14",

.10

5"2

51

41

91

-1B

ALL

TH

RU

ST

BE

AR

ING

- 2"

ID x

3 1

1/32

" O

D2

61

41

91

-2B

ALL

TH

RU

ST

BE

AR

ING

- 1

1/2

" ID

x 2

19/

32"

OD

27

14

19

3-1

TO

GG

LE P

IN A

SS

EM

BLY

- 3

/4"

x 6

1/4"

28

14

23

7Q

UIL

L A

SS

EM

BLY

29

14

24

2H

OU

SIN

G, W

OR

M G

EA

R3

01

42

45

WA

SH

ER

PLA

TE

31

1892

7M

OD

IFIE

D S

OC

KE

T H

EA

D C

AP

SC

RE

W -

1/2"

-13

x 3"

32

1872

8P

IVO

T P

IN, C

YL

RO

D -

1 1

/4"

OD

x 5

3/1

6" L

ON

G3

31

43

41

-1B

US

HIN

G -

2"

ID x

2 1

/4"

OD

x 1

" LO

NG

34

14

34

1-2

BU

SH

ING

- 1

1/2

" ID

x 1

3/4

" O

D x

1"

LON

G3

524

342

FLA

NG

ED

BE

AR

ING

- 2"

BO

RE

x 3

" OD

FLA

NG

E36

*14

344

SH

IM W

AS

HE

R -

1 1

/2"

ID x

2 1

/8"

OD

x .0

05",

.015

", .0

31"

37

18

02

0E

LEC

TR

IC H

YD

RA

ULI

C P

OW

ER

UN

IT3

81

80

20

ELE

CT

RIC

HY

DR

AU

LIC

PO

WE

R U

NIT

39*

1435

3C

OIL

PIN

- 1/

2" O

D x

1 1

/2"

LON

G4

026

374

BA

LL B

EA

RIN

G -

1 1

/4"

BO

RE

x 2

9/1

6" O

D

ITE

M #

PA

RT

#D

ES

CR

IPT

ION

41

1435

6F

LAN

GE

MO

UN

TE

D B

ALL

BE

AR

ING

- 1"

BO

RE

42

1437

7S

PR

OC

KE

T A

ND

SH

AF

T A

SS

Y (1

0T S

PR

OC

KE

T)

43

2438

3B

EA

RIN

G H

OU

SIN

G -

1 1/

8" L

ON

G4

414

384

SP

RO

CK

ET

AN

D S

HA

FT

AS

SY

(40T

SP

RO

CK

ET

)4

517

356

OV

ER

LOA

D A

LAR

M4

61

75

30

WIN

CH

PO

WE

R U

NIT

47

17

47

1R

OT

AT

ION

PO

WE

R U

NIT

48

26

37

5M

AN

IFO

LD, P

RE

SS

UR

E S

WIT

CH

49

26

39

7-3

3.5

CY

LIN

DE

R R

ET

UR

N H

OS

E -

3/8"

x 3

3.5"

50

26

41

5S

WIV

EL

JOIN

T5

12

63

62

SID

E C

OV

ER

52

26

27

2-2

/-3

FR

ON

T C

OV

ER

(-2)

AN

D L

OW

ER

CO

VE

R (-

3)5

314

426

HE

AD

AC

HE

BA

LL A

SS

EM

BLY

- 9

LB

S5

42

63

96

CY

LIN

DE

R H

OS

E, P

RE

SS

UR

E S

WIT

CH

- 3/

8" x

13"

55

26

36

3C

HA

IN C

OV

ER

56

1872

7P

IVO

T P

IN, C

YL

TA

IL -

1 1

/4"

OD

x 3

3/1

6" L

ON

G5

71

44

81

RO

TA

TIO

N D

RIV

E C

HA

IN5

82

58

10

-5/1

6-7

5W

IRE

RO

PE

AS

SY

- 5

/16"

x 7

5 F

T59

*!R

PIN

-025

175

RO

LL P

IN -

1/4

" x

1 3/

4"6

0!H

HC

S03

8162

75H

EX

HE

AD

CA

P S

CR

EW

- 3

/8"-

16 x

2 3

/4"

61

2557

0B

EA

RIN

G A

ND

HO

US

ING

AS

SY

(IT

EM

S 3

5, 4

3)6

22

63

70

WIN

CH

DR

UM

CO

VE

R6

3!S

HC

S05

0201

25S

OC

KE

T H

EA

D C

AP

SC

RE

W -

1/2"

-20

x 1

1/4"

LO

NG

64

!HH

CS

0631

1175

HE

X H

EA

D C

AP

SC

RE

W -

5/8"

-11

x 1

3/4"

LO

NG

65

!JN

UT

-063

11N

SE

LF L

OC

KIN

G J

AM

NU

T -

5/8"

-11

66*

1524

5W

OO

DR

UF

F K

EY

- 5/

16" x

1 1

/8" (

MO

DIF

IED

)67

*26

404

WO

OD

RU

FF

KE

Y -

1/4"

x 1

" (M

OD

IFIE

D)

68

!HW

SH

-050

-LO

CK

HI-

CO

LLA

R L

OC

KW

AS

HE

R -

1/2"

69

2559

3S

ET

SC

RE

W -

1/2

"-20

x 1

"70

*15

675

SH

IM -

1 1

/4"

ID x

.015

", .0

31"

71

26

37

9N

UT

RIN

G7

214

776

GR

OM

ME

T -

5/8"

ID x

7/8

" O

D x

3/1

6" G

RO

OV

E7

31

48

58

-1S

NA

P IN

PLU

G -

7/8"

74

RL-

644

SN

AP

IN P

LUG

- 1"

(SA

ME

AS

ITE

M 7

5)7

5R

L-64

4S

NA

P IN

PLU

G -

1" (S

AM

E A

S IT

EM

74)

76

15

25

1N

UT

BA

R7

71

52

52

NU

T B

AR

78

15

25

3W

AS

HE

R P

LAT

E7

9H

ELB

4MP

-4F

X-9

0S

WIV

EL

AD

AP

TE

R -

90 D

EG

ELB

OW

- 1/

4 N

PT

80

!LN

UT

-038

16LO

CK

NU

T -

3/8"

-16

*1

64

76

SH

IM, P

IN, &

KE

Y K

IT (I

NC

LUD

ES

* IT

EM

S)

22

60

0F

IELD

SE

RV

ICE

LA

BE

L K

IT -

ET

25K

ITE

M #

PA

RT

#D

ES

CR

IPT

ION

SN

: 718

66 &

UP

CIN

CIN

NA

TI,

OH

IOM

AN

UF

AC

TU

RIN

G, I

NC

.

1IT

EM

NO

T S

HO

WN

ON

RE

PLA

CE

ME

NT

PA

RT

S D

RA

WIN

G

1

Page 36: 19938 - Venturo
Page 37: 19938 - Venturo

20197-2

DE

SC

RIP

TIO

N

CO

RD

R

EE

L A

SS

Y

CA

BL

E W

EIG

HT

A

SS

Y

AN

TI T

WO

-B

LO

CK

H

OU

SIN

G A

SS

EM

BL

Y

CO

VE

R - C

OR

D R

EE

L

SN

AP

B

US

HIN

G - 1

/2" I.D

.

SN

AP

B

US

HIN

G - 3

/8" I.D

.

HE

X H

EA

D C

AP

S

CR

EW

- 5/1

6-1

8 x

1

/2"

LIM

IT

S

WIT

CH

LO

CK

W

AS

HE

R - 5/1

6"

SE

T C

OL

LA

R - 3

/3

2"

CA

BL

E C

LA

MP

- 3

/4" x 1

3/3

2" H

OL

E

7

25

10

9

6

8 9

10

3

4

112

13

14

15

19

11

7

16

18

17

C400

19197-2 A

NT

I-T

WO

-B

LO

CK

S

YS

TE

M

RE

PL

AC

EM

EN

T P

AR

TS

D

RA

WIN

G

DA

TE

SU

PE

RS

ED

ES

SE

CT

IO

N

FL

AT

W

AS

HE

R - #6

PA

N H

EA

D M

AC

HIN

E S

CR

EW

- #6-32 x 1 1/4"

HE

X N

UT

- #6-32

LO

CK

W

AS

HE

R - #6

HE

X N

UT

- 1/4-20

HE

X H

EA

D C

AP

S

CR

EW

- 1/4-20 x 3/4"

HE

X H

EA

D C

AP

S

CR

EW

- 1/4-20 x 1 1/2"

HE

X H

EA

D C

AP

S

CR

EW

- 1/4-20 x 1 3/4"

PA

RT

N

O.

QT

YIT

EM

123456789

10

11

112

238

8-1

11119

05

8

11

90

63

192

70

1

19

376

2

!L

WS

H-0

31

11

93

02

19

377

-2

5 5

19

27

5

20

839

HA

NG

ER

C

AB

LE

TIT

LE

!H

HC

S0

311

80

50

21

2

13

14

15

16

17

18

11 222

!H

HC

S0

25

20

175

!F

WS

H-#

06

!P

HM

S#

63

21

25

!L

WS

H-#

06

!H

NU

T-0

25

20

19

1!H

HC

S0

252

01

50

3

20

22

09

51-2

!H

HC

S0

25

20

07

5

!H

NU

T-#

06

32

20

06-03-08F

08-01-16G

MA

NU

FA

CT

UR

IN

G, IN

C.

CIN

CIN

NA

TI, O

HIO

WIR

E T

IE

WIR

E T

IE

CA

BL

E &

C

UT

OF

F S

TE

M

Page 38: 19938 - Venturo
Page 39: 19938 - Venturo

1753

3C

400

5-20

-92A

6-24

-98B

BA

TT

ER

Y &

MO

TO

R C

AB

LE D

IAG

RA

M

ET

20K

(X),

ET

25K

(X),

ET

30K

, E

T36

KX

SU

PE

RC

ED

ES

TIT

LED

AT

ES

EC

TIO

N

CIN

CIN

NA

TI,

OH

IOM

AN

UF

AC

TU

RIN

G, I

NC

.

Page 40: 19938 - Venturo
Page 41: 19938 - Venturo
Page 42: 19938 - Venturo
Page 43: 19938 - Venturo

6

7

43

1

2

BRW R

G

BL

UP

DOWN

UP

DOWN

BOOM

WINCH

ROTATIONLR

5BL

K Y

SEC

TIO

NTI

TLE

DAT

E

SUPE

RSE

DES

BLU

- 12V

+

GRN-

BU

RED-

RL

YEL-

WU

RED/

BLK

- RR

GRN/

BLK

- BD

YEL/

BLK

- WD

PLUG

- BA

CKSI

DE V

IEW

1979

0 3-

SWIT

CH P

ENDA

NT

RED/

BLK

ROTA

TION

RIG

HT

YEL/

BLK

WIN

CH D

OWN

RED

ROTA

TION

LEF

T

GRN/

BLK

BOOM

DOW

N

GRN

BOOM

UP

YEL

WIN

CH U

P

BLU

12V+

3

1715

1-xx

CORD

ASS

Y (x

x =

LENG

TH IN

FT.

)24

348

PLUG

- 7

POLE

313

763

TOGG

LE S

WIT

CH19

793

2553

8DE

CAL

1591

3-2

PHAN

, CLA

MP

AND

TETH

ER A

SSY

1155

7PE

NDAN

T HO

OK

1234567

1111 1

TOGG

LE B

OOT

PART

NO.

QTY

ITEM

DESC

RIPT

ION

REPL

. PAR

TS D

WG.

3 FU

NCTI

ON C

RANE

S4-

10-0

0A

10-1

8-01

BC4

00 1979

1

Page 44: 19938 - Venturo

I175

30C

400

9-20

-90

6-25

-98A

RE

PLA

CE

ME

NT

PA

RT

S

ET

20K

(X),

ET

25K

(X)

SU

PE

RC

ED

ES

TIT

LED

AT

ES

EC

TIO

N

CIN

CIN

NA

TI,

OH

IOM

AN

UF

AC

TU

RIN

G, I

NC

.

Page 45: 19938 - Venturo

REPLACEMENT PARTS LIST - 17530 WINCH POWER UNITMODEL: ET20K(X), ET25K(X)

PART NO. DESCRIPTION

00991 GASKET00992 SEAL00994 WORM SHAFT BUSHING12943-1 SHIM WASHER - 3/4" x 1 1/2" x .005" (AS REQUIRED)12943-2 SHIM WASHER - 3/4" x 1 1/2" x .015" (AS REQUIRED)

12943-3 SHIM WASHER - 3/4" x 1 1/2" x .030" (AS REQUIRED)14082 WORM GEAR14083 BRAKE MOTOR14088 CLUTCH HOUSING (INCLUDES 1/8" x 1/2" ROLL PIN)14089 BRAKE DISC

14150-1 COVER14335 ROLLER CLUTCH14336 THRUST RACE - 1"14337 NEEDLE THRUST BEARING - 1" I.D.14338 THRUST RACE - 3/4"

14339 NEEDLE THRUST BEARING - 3/4" I.D.14343-1 SHIM WASHER - 1" x 1 1/2" x .005" (AS REQUIRED)14343-2 SHIM WASHER - 1" x 1 1/2" x .015" (AS REQUIRED)14343-4 SHIM WASHER - 1" x 1 1/2" x .031" (AS REQUIRED)14345-1 SHIM WASHER - 1" x 2" x .005" (AS REQUIRED)

14345-2 SHIM WASHER - 1" x 2" x .015" (AS REQUIRED)14351 WAVE WASHER14354-2 BALL BEARING14455 GASKET - MOTOR14456-2 BREATHER CAP ASSEMBLY14478 #91 WOODRUFF KEY - 1/4" x 3/4"

14487 MOTOR REPAIR KIT (INCLUDES 00992 SEAL & 14455 GASKET)16485 SHIM, KEY, PIN & SEAL KIT (INCLUDES ITEMS MARKED *)17531 MOTOR (INCLUDES 00992 SEAL)24081 WORM & SHAFT24151 GEAR CASE

25370-1 ROLLER BEARING (INCLUDES 25370-3 SEAL)25370-3 SEAL25409 BEARING & HOUSING ASSEMBLY (INCLUDES 25370-1, 25370-3, 25411 & 568-277-70N)25410 PINION SHAFT & RACE ASSEMBLY25411 BEARING HOUSING

3100-100 RETAINING RING568-227-70N O-RING - 2 1/8" x 2 3/8" x 1/2"- ROLL PIN - 1/8" x 1/2"- ROLL PIN - 3/16" x 3/4"

TITLE SECTION

SUPERCEDES

DATE

900617C400

9-20-90

6-25-98AREPL. PARTS LIST

17530 WINCH PUCINCINNATI, OHIOMFG., INC.

17530 POWER UNIT INTERCHANGEABLE WITH & REPLACES 24408 ON ET20K(X) CRANE

SPECIFY POWER UNIT NUMBER & CRANE SERIAL NUMBERWHEN ORDERING REPLACEMENT PARTS.

1

*

*

**

*

*

**

*

***

*

*

****

1

Page 46: 19938 - Venturo

1747

2C

400

6-25

-98C

1-4-

01D

REP

LAC

EMEN

T PA

RTS

ET20

K(X

), ET

25K

(X),

ET30

KSU

PER

CED

ES

TITL

ED

ATE

SEC

TIO

N

CIN

CIN

NA

TI, O

HIO

MA

NU

FAC

TUR

ING

, IN

C.

(MO

TO

R O

NL

Y)

1435

9

Page 47: 19938 - Venturo

REPLACEMENT PARTS LIST - 17471 ROTATION POWER UNITMODEL: ET20K(X), ET25K(X), ET30K, ET36KX

PART NO. DESCRIPTION

17471 ROTATION POWER UNIT

00986 BRAKE DISK00991 GASKET00994 WORM SHAFT BUSHING01029 BRAKE PLATE01155-1 SPACER

12943-1 SHIM WASHER - 3/4" x 1 1/2" x .005" (AS ERQUIRED)12943-2 SHIM WASHER - 3/4" x 1 1/2" x .015" (AS ERQUIRED)12943-3 SHIM WASHER - 3/4" x 1 1/2" x .030" (AS ERQUIRED)14082 WORM GEAR14146 OUTPUT SHAFT

14150 COVER14338 THRUST RACE - 3/4"14339 NEEDLE THRUST BEARING - 3/4"14340 SHAFT SEAL - 1"14345-1 SHIM WASHER - 1" x 2" x .005" (AS REQUIRED)

14345-2 SHIM WASHER - 1" x 2" x .015" (AS ERQUIRED)14354-2 BALL BEARING14455 GASKET - MOTOR19276 BREATHER CAP ASSEMBLY14478 #91 WOODRUFF KEY - 1/4" x 3/4"24151 GEAR CASE (INCLUDES 1/4" x 1" ROLL PIN)

16115 MOTOR - 12 VOLT, 2 TERMINAL25412 WORM SHAFT & ROTOR ASSEMBLY26154 BRAKE SPRING26157 THRUST WASHER3100-100 RETAINING RING!RPIN-025100 ROLL PIN - 1/4" x 1" (BRAKE PLATE)!RPIN-019075 ROLL PIN - 3/16" x 3/4" (BASE PLATE)

16485 SHIM, KEY, PIN & SEAL KIT (INCLUDES ITEMS MARKED *)17467 MOTOR REPAIR KIT (INCLUDES 14455 GASKET)

TITLE SECTION

SUPERCEDES

DATE

900319C400

6-25-98C

12-18-00DREPL. PARTS LIST

17471 WINCH PUCINCINNATI, OHIOMFG., INC.

17471 POWER UNIT INTERCHANGEABLE AS A COMPLETE UNIT WITH & REPLACES 14407, 14409, 24409 & 26439

SPECIFY POWER UNIT NUMBER & CRANE SERIAL NUMBER WHEN ORDERING REPLACEMENT PARTS.

1

*

16115 MOTOR REPLACES 24364 MOTOR ON 24409 POWER UNITS.16115 MOTOR REPLACES 14362 MOTOR ON 14407 & 14409 POWER UNITS.16115 MOTOR REPLACES 24362 MOTOR ON 26439 POWER UNITS.

2

2

*

***

**

*

*

*

**

1

Page 48: 19938 - Venturo
Page 49: 19938 - Venturo
Page 50: 19938 - Venturo
Page 51: 19938 - Venturo
Page 52: 19938 - Venturo
Page 53: 19938 - Venturo
Page 54: 19938 - Venturo
Page 55: 19938 - Venturo
Page 56: 19938 - Venturo

LIMITED WARRANTY POLICY

This limited policy warrants new products of Venturo be free from defects in material and workmanshipfor a period of one (1) year from date of original installation. This warranty covers:

♦ Repair or replacement of product♦♦♦♦♦ Labor to repair or replace product♦♦♦♦♦ Freight to return and/or replace product

We shall not be liable for any contingent liabilities arising out of the improper function of any products.Warranty shall become void if the product is improperly installed, modified, damaged, abused or usedfor application other than intended use.

WARRANTY CLAIMS

Venturo Manufacturing, Inc. will make a good faith effort for prompt correction or other adjustment withrespect to any product, which proves to be defective after our inspection and within the warranty period.Before any repairs are attempted or before returning any product, your Venturo Distributor is required toobtain a warranty claim number. This number is necessary for any claim to be considered. To obtain awarranty claim number, Venturo requires the model and serial number. Only authorized Venturo Dis-tributors can perform warranty. For the name and address of your local Venturo Distributor call theWarranty Claim Department – 513-772-8448.

WARNING – It is the responsibility of the installer to insure the installation is completed according to themanufacturer’s recommendations, insure the ultimate user understands how to operate product in asafe manner and understands the need for regular service and maintenance by an authorized VenturoDistributor. No modifications or alterations may be made to any Venturo products without the ex-pressed written consent of the manufacturer. Reinstallation of any Venturo product must be done by anauthorized Venturo Distributor, to the standards of the industry including maintenance, service andaffixing of all instruction, safety and warning decals. Users should again be instructed as to the safeoperation at time of delivery. Maintenance, service, operation and safety warning decals are availableon request from Venturo Manufacturing, Inc.

12-00073A

VENTURO MANUFACTURING, INCDIVISION OF COLLINS ASSOCIATES, INC

12110 BEST PLACE CINCINNATI, OHIO 45241513.772.8448

www.venturo.com