19” panel width cable management enclosure

3
96-967/ rev i / 12-1-17 extra wide multi-bay design contains integral cable ducts ideal for accommodating large cable bundles FEATURES: Fully welded construction provides the following weight capacities - UL Listed load capacity:2,500 lbs - Seismic load capacity: 755 lbs. 30” OD width, 31-1/2”, 36” and 42” OD depths available Includes 100 qty. rack screws 4 Grounding and bonding studs installed in base and top 1/2”, 3/4”, 1” & 1-1/2” electrical knockouts on split rear plates (top & bottom), easily removable for cable pass-through, top plates additionally include UHF/ VHF knockouts 2 pairs of wide 11-gauge rackrail labeled with EIA standard rackspace increments available 10-32 threaded or cage-nut style Vented rear door standard One pair of cable ducts with solid steel hinged doors and 4-point magnetic losure pre-installed in front Seismic Certified (when used with MRK-Z4 option) with an Ip value of 1.5 Durable black textured powder coat finish UL Listed in the US and Canada EIA compliant 19” panel width equipment enclosure shall be Middle Atlantic Products model # DRK19-44-__(31, 31PRO, 31K, 36, 36PRO, 42). Overall dimensions of enclosure shall be 83-1/2”H x 30”W x ___(31-1/2”, 36”, 42”)D. Useable height shall be 44 rackspaces, useable depth shall be ___ (24-1/4”, 28-3/4”, 34-3/4”). Fully welded construction shall provide a UL Listed 2,500 lb. weight capacity. Enclosure shall be constructed of the following materials: top, bottom and horizontal braces shall be steel, all structural elements shall be finished in durable black powder coat. Rack shall include a vented, locking and latching rear door. Enclosure shall come equipped with 10” fan top and fan guard for ventilation, one pair of cable ducts with steel doors pre-installed in front of rack, two pairs of rackrail with ____ (tapped 10-32, 6mm cage nut) mounting holes in universal EIA spacing, finished in black e-coat with numbered rackspaces, and vented rear door. Rack shall have a removable rear knockout panel with 1/2”, 3/4”, 1”, and 1-1/2” electrical knockouts installed in base, and removable split rear knockout panels with electrical knockouts and BNC knockouts for UHF/ VHF antennae installed in top. Grounding and bonding studs shall be zinc plated 1/4-20x1 threaded, installed two each in base and top of enclosure (DRK19-44-31K shall additionally include plexiglass front door, one pair lockable side panels, and leveling feet). DRK Series enclosures shall satisfy the 2007 & 2010 CBC; 2006, 2009 & 2012 IBC; ASCE 7-05 (2005 Edition) & ASCE 7-10 (2010 Edition) and the 2006 & 2009 editions of NFPA 5000 for use in areas of high seismicity, Seis- mic Use Group III, Zone 4 or Seismic Design Category (SDC) “D” with lateral force requirements for protecting 755 lbs. of essential equipment in locations with the highest level of seismicity and top floor or rooftop installations with an Importance factor (Ip) of 1.5 when used with MRK-Z4 seismic floor anchor bracket. Rack shall be OSHPD approved for fixed equipment anchorage in California healthcare facilities. DRK shall be UL Listed in the US and Canada. DRK shall be GREENGUARD Gold Certified. DRK enclosure shall be RoHS EU Directive 2011 / 65 / EU compliant. DRK shall be manufacturedbyanISO9001andISO14001registeredcompany.Rackenclosureshallbewarrantiedtobe free from defects in material or workmanship under normal use and conditions for the lifetime of the rack. Customizable specification clips available at middleatlantic.com SPECIFICATIONS: DRK Series 19” PANEL WIDTH CABLE MANAGEMENT ENCLOSURE middleatlantic.com | middleatlantic.ca WHAT GREAT SYSTEMS ARE BUILT ON. OPTIONS: Front doors shall be model # DPVFD-44 (vented plexi), model # DPFD-44 (plexi), model # DVFD-44 (25% open area), model # DLVFD-44 (70% open area) Split rear door, vented with 76% open area shall be model # DCLVRD-44 Additional rail kit, 11-gauge, 10-32 threaded, with EIA numbered spacing shall be model # DRK19-RR44 Additional rail kit, 11-gauge, cage-nut style, with EIA numbered spacing shall be model # DRK19-RR44PRO Caster base shall be model # CBS-DRK-31 (31-1/2” overall depth), CBS-DRK-36 (36” overall depth) Pair of keylocked side panels shall be model # SPN-44-312 (31-1/2” overall depth), SPN-44-36 (36” overall depth), SPN-44-423 (42” overall depth) Optional 10” ventilation fan shall be model # FAN-10 Top panels shall be 16-gauge steel, multiple styles available including model # MW-ST (solid), MW-4FT (four 4-1/2” fans), MW-6FT (three 6” fans), MW-VT (vented) and MW-LA (accepts 6” and 12” cable ladders) Additional cable duct shall be model # DRK-44DUCT, sold individually Rail bracket adapters shall allow for mounting of blank or other panels vertically between rackrail brackets. Available for 44 space enclosures and be model # RBA-MV44-2 (2 rackspaces) Seismic compliancy floor anchor brackets shall be model # MRK-Z4 DRK19-44-31 EIA/TIA COMPLIANT SEISMIC CERTIFIED

Upload: others

Post on 07-Dec-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

96-967/ rev i / 12-1-17

extra wide multi-bay design contains integral cable ducts ideal for accommodating large cable bundles

FEAT

URE

S:

• Fully welded construction provides the following weight capacities - UL Listed load capacity:2,500 lbs - Seismic load capacity: 755 lbs.

• 30” OD width, 31-1/2”, 36” and 42” OD depths available

• Includes 100 qty. rack screws

• 4 Grounding and bonding studs installed in base and top

• 1/2”, 3/4”, 1” & 1-1/2” electrical knockouts on split rear plates (top & bottom), easily removable for cable pass-through, top plates additionally include UHF/ VHF knockouts

• 2 pairs of wide 11-gauge rackrail labeled with EIA standard rackspace increments available 10-32 threaded or cage-nut style

• Vented rear door standard

• One pair of cable ducts with solid steel hinged doors and 4-point magnetic losure pre-installed in front

• SeismicCertified(whenusedwithMRK-Z4option)withanIp value of 1.5

• Durableblacktexturedpowdercoatfinish

• UL Listed in the US and Canada

EIA compliant 19” panel width equipment enclosure shall be Middle Atlantic Products model #DRK19-44-__(31,31PRO,31K,36,36PRO,42).Overalldimensionsofenclosureshallbe83-1/2”Hx30”Wx ___(31-1/2”, 36”, 42”)D.Useable height shall be44 rackspaces, useable depth shall be ___(24-1/4”, 28-3/4”, 34-3/4”). Fully welded construction shall provide a UL Listed 2,500 lb. weightcapacity. Enclosure shall be constructed of the following materials: top, bottom and horizontalbraces shall be steel, all structural elements shall be finished in durable black powder coat. Rackshall include a vented, locking and latching rear door. Enclosure shall come equipped with 10” fan top and fan guard for ventilation, one pair of cable ducts with steel doors pre-installed in front of rack, twopairsof rackrailwith____ (tapped10-32,6mmcagenut)mountingholes inuniversalEIAspacing,finishedinblacke-coatwithnumberedrackspaces,andventedreardoor.Rackshallhavearemovable rear knockout panel with 1/2”, 3/4”, 1”, and 1-1/2” electrical knockouts installed in base, and removable split rear knockout panels with electrical knockouts and BNC knockouts for UHF/VHF antennae installed in top. Grounding and bonding studs shall be zinc plated 1/4-20x1 threaded, installed two each in base and top of enclosure (DRK19-44-31K shall additionally includeplexiglass front door, one pair lockable side panels, and leveling feet). DRKSeries enclosures shallsatisfy the 2007 & 2010 CBC; 2006, 2009 & 2012 IBC; ASCE 7-05 (2005 Edition) & ASCE 7-10 (2010Edition)andthe2006&2009editionsofNFPA5000foruseinareasofhighseismicity,Seis-micUseGroup III,Zone4orSeismicDesignCategory (SDC) “D”with lateral force requirements forprotecting 755 lbs. of essential equipment in locations with the highest level of seismicity and top flooror rooftop installationswithan Importance factor (Ip)of1.5whenusedwithMRK-Z4seismicfloor anchor bracket. Rack shall be OSHPD approved for fixed equipment anchorage in Californiahealthcare facilities. DRK shall be UL Listed in the US and Canada. DRK shall be GREENGUARDGold Certified. DRK enclosure shall be RoHS EUDirective 2011 / 65 / EU compliant. DRK shall bemanufacturedbyanISO9001andISO14001registeredcompany.Rackenclosureshallbewarrantiedtobefree from defects in material or workmanship under normal use and conditions for the lifetime of the rack.

Customizablespecificationclipsavailableatmiddleatlantic.com

SPEC

IFIC

ATIO

NS:

DRK Series19” PANEL WIDTH CABLE MANAGEMENT ENCLOSURE

middleatlantic.com | middleatlantic.ca

WHAT GREAT SYSTEMS ARE BUILT ON.™

OPTIONS:• Frontdoorsshallbemodel#DPVFD-44(ventedplexi), model#DPFD-44(plexi),model#DVFD-44(25%open area),model#DLVFD-44(70%openarea)• Splitreardoor,ventedwith76%openareashallbe model#DCLVRD-44• Additional rail kit, 11-gauge, 10-32 threaded, with EIA numberedspacingshallbemodel#DRK19-RR44• Additional rail kit, 11-gauge, cage-nut style, with EIA numberedspacingshallbemodel#DRK19-RR44PRO• Casterbaseshallbemodel#CBS-DRK-31(31-1/2” overalldepth),CBS-DRK-36(36”overalldepth)• Pairofkeylockedsidepanelsshallbemodel# SPN-44-312(31-1/2”overalldepth),SPN-44-36 (36”overalldepth),SPN-44-423(42”overalldepth)• Optional10”ventilationfanshallbemodel#FAN-10• Top panels shall be 16-gauge steel, multiple styles availableincludingmodel#MW-ST(solid),MW-4FT (four4-1/2”fans),MW-6FT(three6”fans),MW-VT (vented)andMW-LA(accepts6”and12”cableladders)• Additionalcableductshallbemodel#DRK-44DUCT, sold individually• Railbracketadaptersshallallowformountingofblank or other panels vertically between rackrail brackets. Availablefor44spaceenclosuresandbemodel# RBA-MV44-2(2rackspaces)• Seismic compliancy floor anchor brackets shall be model#MRK-Z4

DRK19-44-31

EIA/TIA COMPLIANT

SEISMIC CERTIFIED

2

middleatlantic.com | middleatlantic.ca

WHAT GREAT SYSTEMS ARE BUILT ON.™

DRK SeriesBASIC DIMENSIONS

22.88[581]

19.50[495]

83.49[2121]

OVERALLW/ FAN TOP

77.13[1959]

44 USEABLERACK SPACES

"A""B"

USEABLEDEPTH

30.00 [762]

.78 [20]

7.44 [189]1.72 [44]

5.94 [151]

1.50[38]

2.13[54] 8.41 [214]

MODEL #. REAR DOOR RAIL TYPE A B C D E

DRK19-44-31 YES 10-32 THREADED

31.40 [798] 24.25 [616] 27.26 [692] 29.29 [744] 26.51 [673]

DRK19-44-31LRD NO 10-32 THREADED

DRK19-44-31PRO YES CAGE NUT

DRK19-44-31PROLRD NO CAGE NUT

DRK19-44-31K* YES 10-32 THREADED

DRK19-44-36 YES 10-32 THREADED

36.00 [914] 28.85 [733] 31.86 [809] 33.89 [861] 31.11 [790]DRK19-44-36LRD NO 10-32 THREADED

DRK19-44-36PRO YES CAGE NUT

DRK19-44-36PROLRD NO CAGE NUT

DRK19-44-42 YES 10-32 THREADED

42.00 [1067] 34.85 [885] 37.86 [962] 39.89 [1013] 37.11 [943]DRK19-44-42LRD NO 10-32 THREADED

DRK19-44-42PRO YES CAGE NUT

DRK19-44-42PROLRD NO CAGE NUT

*INCLUDES PLEXI FRONT DOOR, LEVELING FEET, REMOVABLE SIDE PANELS

REMOVABLE EKO PLATES

19 [483]PANELWIDTH

SIDE VIEW

NOTE:ALL DIMENSIONS IN FORMAT:INCHES [MILLIMETERS]

FRONT VIEW

SEE DETAIL A

REAR VIEWVIEWS SHOWN WITH REAR DOOR REMOVED

OPENING (8X).875 X 4.875[22] [124]

SEE DETAIL B

TOP VIEW

DIMENSIONAL NOTES:- SPN-44-XXX ADDS .625 [16] PER SIDE TO OVERALL WIDTH.- CBS-DRK-XX ADDS .75 [19] TO OVERALL HEIGHT.- DXFD-44 ADDS .92 [23] TO OVERALL DEPTH.- REMOVAL OF FAN TOP REDUCES HEIGHT BY .375 [10].

GRILL FOR 10 [254] FAN(FAN NOT INCLUDED)

2 RACKSPACEREMOVABLE SERVICE PLATE

TOP OPENING DIMENSIONSWITH FAN TOP REMOVED

DETAIL ASCALE 1/16

1" [25] & 1-1/2" [38] EKO1/2" [13] & 3/4" [19] EKO5/8" [16] DIA KO

1/2" [13] DIA "D" KO(UHF/VHF ANTENNA KO)

SCALE 1/32

SCALE 1/16DETAIL B

1" [25] & 1-1/2" [38] EKO

3

middleatlantic.com | middleatlantic.ca

WHAT GREAT SYSTEMS ARE BUILT ON.™

DRK SeriesBASIC DIMENSIONS

25.13[638]

2.38 [60]

27.88[708]

.72[18]

"D"

"E"

"C"

26.87[683]

8X .44 [11]

4.25 [108]

4.13[105]OVERALL WIDTH(3.25 [83] OPENING WIDTH)

76.75[1949]

1.473 [37]

2.000 [51]BOTTOM VIEWSCALE 1/16

FLOOR MOUNTINGLOCATIONSSCALE 1/16

SIDEVIEW

OPENING 2.250 X 3.000[57] [76]

(21X THIS SIDE17X OTHER SIDE)

REARVIEW

OPENING (8X).875 X 4.875[22] [124]

TOP VIEW

TOP OPENING

FRONT VIEW(DOOR OPEN)

SOLID HINGEDDOOR WITH

4 POINTMAGNETICCLOSURE

CABLE DUCT

NO

NOTE:ALL DIMENSIONS IN FORMAT:INCHES [MILLIMETERS]