1756-sg001o-en-p, controllogix selection guidemediaserver.voxtechnologies.com/filecache/rockwell...

44
Selection Guide ControlLogix System Catalog Numbers 1756 Series 1756 ControlLogix I/O Modules 1756 ControlLogix Integrated Motion 1756 ControlLogix Communication Modules 1756 ControlLogix Controllers 1756 ControlLogix Chassis 1756 ControlLogix Power Supplies

Upload: vanquynh

Post on 12-Jun-2018

232 views

Category:

Documents


0 download

TRANSCRIPT

Selection Guide

ControlLogix SystemCatalog Numbers 1756 Series

1756 ControlLogix IO Modules1756 ControlLogix Integrated Motion

1756 ControlLogix Communication Modules1756 ControlLogix Controllers

1756 ControlLogix Chassis1756 ControlLogix Power Supplies

2 Rockwell Automation Publication 1756-SG001P-EN-P - May 2011

Logix Controllers ComparisonCharacteristic 1756 ControlLogix 1756 GuardLogix 1768

CompactLogix1768 Compact GuardLogix

1769-L3x CompactLogix

1769-L23x CompactLogix

1789 SoftLogix5800

Controller tasksbull Continuousbull Periodicbull Event

bull 32 tasksbull 100 programstaskbull Event tasks all event triggers

bull 32 tasksbull 100 programstaskbull Event tasks all event triggers

bull 16 tasksbull Event tasks consumed tag EVENT instruction axis and motion event triggers

bull 16 tasksbull Event tasks consumed tag EVENT instruction axis and motion event triggers

bull 1769-L35x 8 tasksbull 1769-L32x 6 tasksbull 1769-L31 4 tasksbull Event tasks consumed tag and EVENT instruction triggers

bull 3 tasksbull 16 programstaskbull Event tasks consumed tag and EVENT instruction triggers

bull 32 tasksbull 100 programstaskbull Event tasks all event triggers plus outbound and Windows events

User memory 1756-L61 2 MB1756-L62 4 MB1756-L63 8 MB1756-L64 16 MB1756-L65 32 MB

1756-L72 4 MB1756-L73 8 MB1756-L74 16 MB1756-L75 32 MB

1756-L61S2 MB Standard1 MB Safety

1756-L62S4 MB Standard1 MB Safety

1756-L63S8 MB Standard375 MB Safety

1768-L43 2 MB1768-L45 3 MB

1768-L43S2 MB Standard05 MB Safety

1768-L45S3 MB Standard1 MB Safety

1769-L31 512 KB1769-L32x 750 KB1769-L35x 15 MB

512 KB 1789-L102 MB 1 controller no motion

1789-L3064 MB 3 controllers

1789-L6064 MB 6 controllers

Nonvolatile user memory

1756-L6x CompactFlash

1756-L7xSecure Digital card

CompactFlash CompactFlash CompactFlash CompactFlash None None

Built-in communication ports

1756-L6x 1 port RS-232 serial

1756-L7x 1 port USB

1 port RS-232 serial 1 port RS-232 serial 1 port RS-232 serial bull 1769-L31 2 RS-232 portsbull 1769-L32C 1769-L35CR 1 ControlNet port and 1 RS-232 serial portbull 1769-L32E 1769-L35E 1 EtherNetIP port and 1 RS-232 serial port

bull 1769-L23E-QB1B 1 EtherNetIP port and 1 RS-232 serial portbull 1769-L23E-QBFC1B 1 EtherNetIP port and 1 RS-232 serial portbull 1769-L23-QBFC1B 2 RS-232 serial ports

Depends on personal computer

Communication options bull EtherNetIPbull ControlNetbull DeviceNetbull Data Highway Plusbull Remote IObull SynchLink

bull EtherNetIP (standard and safety)bull ControlNet (standard and safety)bull DeviceNet (standard and safety)bull Data Highway Plusbull Remote IObull SynchLink

bull EtherNetIPbull ControlNetbull DeviceNet

bull EtherNetIP (standard and safety)bull ControlNet (standard and safety)bull DeviceNet (standard)

bull EtherNetIPbull ControlNetbull DeviceNet

bull EtherNetIPbull DeviceNet

bull EtherNetIPbull ControlNetbull DeviceNet

Controller connections 1756-L6x 250

1756-L7x 500

250 250 250 100 100 250

Network connections Per network modulebull 100 ControlNet (CN2A)bull 40 ControlNet (CNB)bull 256 EtherNetIP 128 TCP (EN2x)bull 128 EtherNetIP 64 TCP (ENBT)

Per network modulebull 100 ControlNet (CN2A)bull 40 ControlNet (CNB)bull 256 EtherNetIP 128 TCP (EN2x)bull 128 EtherNetIP 64 TCP (ENBT)

Per network modulebull 48 ControlNetbull 128 EtherNetIP 64 TCP

Per network modulebull 48 ControlNetbull 128 EtherNetIP 64 TCP

Per controllerbull 32 ControlNetbull 32 EtherNetIP 32 TCP

Per controllerbull 32 EtherNetIP 8 TCP

Per network modulebull 48 ControlNetbull 128 EtherNetIP 64 TCP

Controller redundancy Full support None Backup via DeviceNet

Backup via DeviceNet

Backup via DeviceNet

Backup via DeviceNet NA

Simple motion bull Stepperbull Servo via DeviceNetbull Analog or networked AC drive

bull Stepperbull Servo via DeviceNetbull Analog or networked AC drive

bull Stepperbull Servo via DeviceNetbull Analog or networked AC drive

bull Stepperbull Servo via DeviceNetbull Analog or networked AC drive

bull Stepperbull Servo via DeviceNetbull Analog or networked AC drive

bull Stepperbull Servo via DeviceNetbull Analog or networked AC drive

bull Stepperbull Servo via DeviceNetbull Analog or networked AC drive

Integrated motion EtherNetIPSERCOS interfaceAnalog optionsbull Encoder inputbull LDT inputbull SSI input

EtherNetIPSERCOS interfaceAnalog optionsbull Encoder inputbull LDT inputbull SSI input

SERCOS interface SERCOS interface NA NA SERCOS interfaceAnalog encoder input

Programming languages

bull Relay ladderbull Structured textbull Function blockbull Sequential function chart

bull Standard task all languagesbull Safety task relay ladder safety application instructions

bull Relay ladderbull Structured textbull Function blockbull Sequential function chart

bull Standard task all languagesbull Safety task relay ladder safety application instructions

bull Relay ladderbull Structured textbull Function blockbull Sequential function chart

bull Relay ladderbull Structured textbull Function blockbull Sequential function chart

bull Relay ladderbull Structured textbull Function blockbull Sequential function chartbull External routines (developed in CC++)

Select a ControlLogix System

Step 1ControlLogix IO Modules

Step 2ControlLogix Integrated Motion

Step 3ControlLogix Communication Modules

1756 ControlLogix System

Step 4ControlLogix Controllers

Step 5ControlLogix Chassis

Step 6ControlLogix Power Supplies

Select IO modules - some modules have field-side

diagnostics electronic fusing or individually isolated inputsoutputs

A remote terminal block (RTB) or wiring system for each IO module

Select A SERCOS or analog interface module

Associated cables

A removable terminal block (RTB) - only for analog interface modules

Select drives motors and accessories (use the Motion Analyzer software)

Select Networks

Communication modules

Associated cables and network equipment

Sufficient modules and cables if you are planning a redundant system

Select A controller with sufficient memory

Secure Digital or CompactFlash card

Replacement batteries if needed

Select A chassis with sufficient slots

Slot fillers for empty slots

Select One power supply for each chassis if you are using

standard power supplies

A power supply bundle if you are planning a redundant power supply system

Optional StepProgramming Software

Optional StepVisualization Products

Page 8

Page 15

Page 18

Page 27

Page 32

Page 34

Page 35 Page 36

3Publication 1756-SG001P-EN-P - May 2011 3

ControlLogix System Overview

The ControlLogix system provides discrete drives motion process and safety control together with communication and state-of-the-art IO in a small cost-competitive package The system is modular so you can design build and modify it efficiently with significant savings in training and engineering

Example Configuration - ControlLogix System

A simple ControlLogix system consists of a standalone controller and IO modules in a single chassis For a more comprehensive system use the following

Multiple controllers in a single chassis Multiple controllers joined across networks IO in multiple platforms that are distributed in many locations and

connected over multiple IO links

RUN IO

RS232

OK

FORCE

BAT

RUN REM PROG

Logix5564

OKCP

SERCOS

OKAB

OKIOMODNET OKIOMODNET

ST

ST

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

HART

ANALOG INPUT

OK

DIAGNOSTIC

FLT

ST

FLT

ST

0 1 2 3 4 5 6 7

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

8 9 10 11 12 13 14 15

DC OUTPUT

DIAGNOSTIC

FLT

ST

FLT

ST

0 1 2 3 4 5 6 7

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

8 9 10 11 12 13 14 15

DC INTPUT

POWER

STATUS

WDOG

BATT

NS

MODE

H1-1H1-2H1-3H1-4

DANGERDANGERDANGERDANGER

755

98

2

5

0

3

6

7

1

4

Logix55LSP

SAFETY

RUN

SAFETY

TASK

BAT OK

RUN IO

RS232

OK

FORCE

BAT

RUN REM PROG

Logix5561

Plant MRP SystemDatabaseTracking Systems

Laptop

Stratix 8000

POINT Guard IO

FLEX IO

PanelView Plus

PowerFlex 755

CompactBlock Guard IO

PowerFlex 70

Other Devices

EtherNetIP

Kinetix Servo Drive

Motor Feedback

Servo Motor

Motor Power

DeviceNet

FLEX IO-XT

Tower LightArmorBlock Guard IO

PowerFlex 70

Valve

Guard IO

HART

ControlNet

Flowmeter

LevelFoundation Fieldbus

1756

-L61

S17

56-L

SP17

56-L

64SE

RCOS

1756

-EN

2T17

56-C

N2

1756

-DN

BIO IO An

alog

4 Publication 1756-SG001P-EN-P - May 2011

ControlLogix-XT System

The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh corrosive environments

When used with FLEX IO-XT products the ControlLogix-XT system can withstand temperatures range from -2070 C (-4158 F)

When used independently the ControlLogix-XT system can withstand temperature ranges from -2570 C (-13158 F)

GuardLogix Safety System

A GuardLogix controller is a ControlLogix controller that also provides safety control The GuardLogix system is a dual controller solution mdash you must use a 1756-L6xS primary controller and a 1756-LSP safety partner to achieve SIL 3CAT 4 A major benefit of this system is that itrsquos still a single project safety and standard together The safety partner controller is a part of the system is automatically configured and requires no user setup

Application Description

SIL 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508 and applications up to and including category (CAT) 4 according to EN954-1 For more information see the following GuardLogix Controllers Systems Safety Reference Manual publication 1756-RM093 GuardLogix Controllers User Manual publication 1756-UM020 GuardLogix Safety Application Instruction Set Reference Manual publication 1756-RM095

SIL 2 Components of the ControlLogix system are type-approved and certified for use in SIL 2 applications according to IEC 61508 and AK4 applications according to DIN V19250 For a list of ControlLogix system components that meet SIL 2 requirements see Using ControlLogix in SIL 2 Applications Safety Reference Manual publication 1756-RM001

Publication 1756-SG001P-EN-P - May 2011 5

Example Configuration - Redundant ControlLogix System

The ControlLogix controller supports controller redundancy

OKAB

AB

DIAGNOSTIC

FLT

ST

FLT

ST

0 1 2 3 4 5 6 7

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

8 9 10 11 12 13 14 15

DC INTPUT

DIAGNOSTIC

FLT

ST

FLT

ST

0 1 2 3 4 5 6 7

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

8 9 10 11 12 13 14 15

DC OUTPUT

ST

ST

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

HART

ANALOG INPUT

OK

DIAGNOSTIC

FLT

ST

FLT

ST

0 1 2 3 4 5 6 7

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

8 9 10 11 12 13 14 15

DC INTPUT

DIAGNOSTIC

FLT

ST

FLT

ST

0 1 2 3 4 5 6 7

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

8 9 10 11 12 13 14 15

DC OUTPUT

ST

ST

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

HART

ANALOG INPUT

OK

POWER

OKAB

AB

OKCOMMPRI

REDUNDANCY MODULE

RUN IO

RS232

OK

FORCE

BAT

RUN REM PROG

Logix5564

RUN IO

RS232

OK

FORCE

BAT

RUN REM PROG

Logix5562

OKNETLINK

POWERPOWER

POWER

OKAB

AB

OKCOMMPRI

REDUNDANCY MODULE

RUN IO

RS232

OK

FORCE

BAT

RUN REM PROG

Logix5564

RUN IO

RS232

OK

FORCE

BAT

RUN REM PROG

Logix5562

OKNETLINK

ESC SEL

EOI or HMI

EtherNetIP or ControlNet

1756-RM

1756-EN2T

1756-CN2RB1756-RM

1756-L61 1756-L62 or 1756-L63

1756-EN2T

1756-CN2RB

Primary ControlLogix Chassis Secondary ControlLogix Chassis

Fiber Optic Cable

FLEX IO

1203-CN1

1336 Plus II AC Drive

1756-CNBR

1756-PA75R or 1756-PB75R Redundant Power Supplies Redundant ControlNet

ControlLogix IO1756-PSCA2 Chassis Adapter

1756-CPR2 Cables

1756-L61 1756-L62 or 1756-L63

6 Publication 1756-SG001P-EN-P - May 2011

Example Configuration - Redundant IO System

The 1715 redundant IO system lets a ControlLogix controller communicate to a remote redundant IO chassis over an EtherNetIP network The 1715 redundant IO system provides fault tolerance and redundancy for critical processes by using a redundant adapter pair and multiple IO modules that have diagnostics

The redundant IO system must be connected to a ControlLogix system via an EtherNetIP network All connections are established via the Ethernet network by using the topologies supported by the 1756-EN2TR communication bridge

For detailed specifications see the 1715 Redundant IO System Specifications Technical Data publication 1715-TD001A-EN-P

1756

-RM

1756

-EN

2TR

IO B

ASE

1715

-A31

0

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

IO B

ASE

1715

-A31

0

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

1715

-AEN

TR

1756

-EN

2TR

1756

-RM

1715

-AEN

TR

1715

-IO

1715

-IO

1715

-IO

1715

-IO

1715

-IO

1715

-IO

ControlLogix Primary Chassis ControlLogix Secondary Chassis

1715 Redundant IO System

Publication 1756-SG001P-EN-P - May 2011 7

ControlLogix IO Modules The ControlLogix architecture provides a wide range of input and output modules to span many applications from high-speed digital to process control The ControlLogix architecture uses a producerconsumer model so that input information and output status can be shared among multiple controllers

Each ControlLogix IO module mounts in a ControlLogix chassis and requires either a removable terminal block (RTB) or a 1492 interface module (IFM) to connect all field-side wiring RTBs and IFMs are not included with the IO modules They must be ordered separately

For detailed specifications see 1756 ControlLogix IO Modules Specifications publication 1756-TD002

AC Digital put Modules

AC Digital Output Modules

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

1756-IA8D 8 diagnostic inputs(4 pointsgroup)

120V AC 79hellip132V AC 1756-TBNH1756-TBSH

1756-IA16 16 inputs(8 pointsgroup)

120V AC 74hellip132V AC 1756-TBNH1756-TBSH

1756-IA16I 16 individually isolated inputs 120V AC 74hellip132V AC 1756-TBCH1756-TBS6H

1756-IA32 32 diagnostic inputs(4 pointsgroup)

120V AC 74hellip132V AC 1756-TBCH1756-TBS6H

1756-IM16I 16 individually isolated inputs 240V AC 159hellip265V AC 1756-TBCH1756-TBS6H

1756-IN16 16 inputs(8 pointsgroup)

24V AC 10hellip30V AC 1756-TBNH1756-TBSH

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

1756-OA8 8 outputs(4 pointsgroup)

120240V AC 79hellip265V AC 1756-TBNH1756-TBSH

1756-OA8D 8 diagnostic electronically fused outputs(4 pointsgroup)

120V AC 74hellip132V AC 1756-TBNH1756-TBSH

1756-OA8E 8 electronically fused outputs(4 pointsgroup)

120V AC 74hellip132V AC 1756-TBNH1756-TBSH

1756-OA16 16 mechanically fusedgroup outputs(8 pointsgroup)

120240V AC 74hellip265V AC 1756-TBNH1756-TBSH

1756-OA16I 16 individually isolated outputs

120240V AC 74hellip265V AC 1756-TBCH1756-TBS6H

1756-ON8 8 outputs(4 pointsgroup)

24V AC 10hellip30V AC current gt50 mA16hellip30V AC current lt50 mA

1756-TBNH1756-TBSH

8 Publication 1756-SG001P-EN-P - May 2011

DC Digital Input Modules

DC Digital Output Modules

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

1756-IB16 16 inputs(8 pointsgroup)

1224V DC sink 10312V DC 1756-TBNH1756-TBSH

1756-IB16D 16 diagnostic inputs(4 pointsgroup)

1224V DC sink 1030V DC 1756-TBCH1756-TBS6H

1756-IB16I 16 individually isolated inputs 1224V DC sinksource 1030V DC 1756-TBCH1756-TBS6H

1756-IB16ISOE 16 individually isolated sequence of events inputs

2448V DC sinksource 1055V DC 1756-TBCH1756-TBS6H

1756-IB32 32 inputs(16 pointsgroup)

1224V DC sink 10312V DC 1756-TBCH1756-TBS6H

1756-IC16 16 inputs(8 pointsgroup)

48V DC sink 3055V DC 60 degC (140 degC)3060V DC 55 degC (131 degC)

1756-TBNH1756-TBSH

1756-IG16 16 inputs(8 pointsgroup)

5V DC TTL source (Low=True)

4555V DC 1756-TBNH1756-TBSH

1756-IH16I 16 individually isolated inputs 125V DC sinksource 90146V DC 1756-TBCH1756-TBS6H

1756-IH16ISOE 16 individually isolated sequence of events inputs

125V DC sinksource 90140V DC 1756-TBCH1756-TBS6H

1756-IV16 16 inputs(8 pointsgroup)

1224V DC source 1030V DC 1756-TBNH1756-TBSH

1756-IV32 32 inputs(16 pointsgroup)

1224V DC source 1030V DC 1756-TBCH1756-TBS6H

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

1756-OB8 8 outputs 1224V DC source 1030V DC 1756-TBNH1756-TBSH

1756-OB8EI 8 electronically fused individually isolated outputs

1224V DC source 1030V DC 1756-TBCH1756-TBS6H

1756-OB8I 8 individually isolated outputs 1224V DC source 1030V DC 1756-TBCH1756-TBS6H

1756-OB16D 16 diagnostic outputs(8 pointsgroup)

24V DC source 19230V DC 1756-TBCH1756-TBS6H

1756-OB16E 16 electronically fused outputs(8 pointsgroup)

1224V DC source 10312V DC 1756-TBNH1756-TBSH

1756-OB16I 16 individually isolated outputs

1224V DC sinksource 1030V DC 1756-TBCH1756-TBS6H

1756-OB16IS 16 individually isolated outputs8 scheduled outputs

1224V DC sinksource 1030V DC 1756-TBCH1756-TBS6H

1756-OB32 32 outputs(16 pointsgroup)

1224V DC source 10312V DC 1756-TBCH1756-TBS6H

Publication 1756-SG001P-EN-P - May 2011 9

Contact Output Modules

Analog Input Modules

1756-OC8 8 outputs(4 pointsgroup)

48V DC source 3060V DC 1756-TBNH1756-TBSH

1756-OG16 16 (8 pointsgroup) 5V DC TTL source (Low=True)

4555V DC 1756-TBNH1756-TBSH

1756-OH8I 8 outputsindividually isolated

120V DC 90146V DC 1756-TBCH1756-TBS6H

1756-OV16E 16 electronically fused outputs(8 pointsgroup)

1224V DC sink 1030V DC 1756-TBNH1756-TBSH

1756-OV32E 32 electronically fused outputs (16 pointsgroup)

1224V DC sink 1030V DC 1756-TBCH1756-TBS6H

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

Cat No InputsOutputs Operating Voltage Range Removable Terminal Block

1756-OW16I 16 normally open individually isolated outputs 5150V DC10265V AC

1756-TBCH1756-TBS6H

1756-OX8I 8 normally open8 normally closed individually isolated outputs(2 pointsgroup)

5150V DC10265V AC

1756-TBCH1756-TBS6H

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-IF6CIS 6 individually isolated inputs current sourcing

0hellip21 mA 16 bits034 Abit

1756-TBNH1756-TBSH

1756-IF6I 6 individually isolated inputs plusmn105V0hellip105V0hellip525V0hellip21 mA

16 bits105V 343 Vbit0hellip105V 171 Vbit0hellip525V 86 Vbit0hellip21 mA 034 Abit

1756-TBNH1756-TBSH

1756-IF8 8 single-ended inputs4 differential inputs2 high-speed differential inputs

plusmn1025V01025V05125V0hellip205 mA

plusmn1025V 320 Vcnt (15 bits plus sign bipolar)0hellip1025V 160 Vcnt (16 bits)0hellip5125V 80 V cnt (16 bits)0hellip205mA 032 Acnt (16 bits)

1756-TBCH1756-TBS6H

10 Publication 1756-SG001P-EN-P - May 2011

Analog RTD and Thermocouple Modules

Analog Output Modules

1756-IF8H 8 differential voltage or current inputs HART interface

plusmn10V05V1hellip5V010V0hellip20 mA4hellip20 mA

16hellip21 bits 1756-TBCH1756-TBS6H

1756-IF16 16 single-ended inputs8 differential or 4 differential (high speed) inputs

plusmn105V0hellip105V0hellip525V0hellip21 mA

16 bits105V 343 Vbit0hellip105V 171 Vbit0hellip525V 86 Vbit0hellip21 mA 034 Abit

1756-TBCH1756-TBS6H

1756-IF16H 16 differential current inputs HART interface

0hellip20 mA4hellip20 mA

16hellip21 bits 1756-TBCH1756-TBS6H

Cat No InputsOutputs Range Resolution Removable Terminal Block

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-IR6I 6 individually isolated RTD inputs 1hellip487 2hellip1000 4hellip20008hellip4020

16 bits1hellip487 77 mbit2hellip1000 15 mbit4hellip2000 30 mbit8hellip4020 60 mbit

1756-TBNH1756-TBSH

1756-IT6I 6 individually isolated thermocouple inputs1 CJC

-12hellip78 mV-12hellip30 mV

16 bits-1278 mV 14 Vbit-1230 mV 07 Vbit

1756-TBNH1756-TBSH

1756-IT6I2 6 individually isolated thermocouple inputs2 CJC

-12hellip78 mV (14 V per bit)-12hellip30 mV (07 V per bit ndash high resolution range)

16 bits-1278 mV 14 Vbit-1230 mV 07 Vbit

1756-TBNH1756-TBSH

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-OF4 4 voltage or current outputs plusmn104V0hellip21 mA

Voltage15 bits across 105V 320 VbitCurrent15 bits across 21mA 650 nAbit

1756-TBNH1756-TBSH

1756-OF6CI 6 individually isolated outputs current

0hellip21 mA 13 bits across 21 mA (27 A) 1756-TBNH1756-TBSH

1756-OF6VI 6 individually isolated outputs voltage

plusmn105V 14 bits across 21V (13 mV)(13 bits across 105V +sign bit)

1756-TBNH1756-TBSH

1756-OF8 8 voltage or current outputs plusmn104V0hellip21 mA

15 bits across 21 mA - 650 nAbit15 bits across 104V - 320 Vbit

1756-TBNH1756-TBSH

1756-OF8H 8 voltage or current outputs HART interface

plusmn104V0hellip20 mA4hellip20 mA

15hellip16 bits 1756-TBNH1756-TBSH

Publication 1756-SG001P-EN-P - May 2011 11

Analog Combination Input and Output Module

Specialty IO Modules

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-IF4FXOF2F 4 high-speed sub-millisecond differential inputs2 high-speed voltage or current outputs

Inputplusmn105V0hellip105V0hellip525V0hellip21 mAOutputplusmn104V0hellip21 mA

InputApprox 14 bits across plusmn10V DC (21V total)plusmn10V 13 mVbit 14-bit effective0hellip105V 13 mVbit 13-bit effective0hellip525V 13 mVbit 12-bit effectiveApprox 12 bits across 21 mA0hellip21 mA 525 AbitOutput13 bits across 21 mA = 28 Abit14 bits across 218V = 13 mVbit

1756-TBCH1756-TBS6H

Cat No InputsOutputs Description Removable Terminal Block

1756-CFM 4 inputs (2 per channel) 2 outputs current sourcing

Configurable flowmeter module2 Flowmeter (F) inputs used for all modes2 Gate inputs used in Totalizer mode for proverstore count

1756-TBNH1756-TBSH

1756-HSC 2 counters each with 3 inputs (A B Z for gatereset)4 outputs (2 pointsgroup)

High-speed counter module5V operation 45hellip55V DC1224V operation 10hellip312V DC

1756-TBCH1756-TBS6H

1756-PLS Left section 2 groups of 4 outputs and 4 inputs eachCenter section resolver interface and IO controlRight section 2 groups of 4 outputs and 4 inputs each

Programmable limit switch module Requires 3 RTBs 1756-TBNH or 1756-TBSH

12 Publication 1756-SG001P-EN-P - May 2011

HART Smart Instrumentation

HART (Highway Addressable Remote Transmitter) is an open protocol designed to connect analog devices For HART connectivity select from products available from Rockwell Automation and our Encompass partners

Typical HART Configuration

HART Interfaces

Accessories - IO Modules

1756 Removable Terminal Blocks

Removable terminal blocks (RTBs) provide a flexible interconnection between your plant wiring and 1756 IO modules The RTB plugs into the front of the IO module The type of module determines which RTB you need You can choose screw-clamp or spring-clamp RTBs

RTBs are not shipped with IO modules You must order them separately The standard housing on the front of the wiring arm is not deep enough for 25 mm2

HART Devices

ControlLogix Controller with 1756-IF8H or 1756-OF8H module

If your application has Select Description

Analog and HART connectivity in one moduleNo external hardware required to access HART signalHART commands can be transmitted as unscheduled messagesSupports asset management software to HART device

1756-IF8H1756-IF16H1756-OF8H

Rockwell Automation analog IO modules

Data acquisition or control application with slow update requirements (such as a tank farm)No external hardware required to access HART signalDoes not connect directly to asset management software

MVI56-HART Prosoft interface

Analog and HART in one moduleInstrumentation in hazardous locations (FLEX Ex modules)HART commands can be transmitted as unscheduled messagesDirectly connects asset management software to HART devices

1794 FLEX IO1797 FLEX Ex IO

There are specific FLEX IO and FLEX Ex modules designed for HART systems These catalog numbers end in an H such as 1797-IE8H

Publication 1756-SG001P-EN-P - May 2011 13

(14 AWG) wiring If you plan to use 25 mm2 (14 AWG) wiring also order the extended housing

Wiring Systems

As an alternative to buying RTBs and connecting the wires yourself you can buy a wiring system of the following

Interface modules (IFMs) that provide the output terminal blocks for digital IO modules Use the pre-wired cables that match the IO module to the IFM

Analog interface modules (AIFMs) that provide the output terminal blocks for analog IO modules Use the pre-wired cables that match the IO module to the AIFM

IO module-ready cables One end of the cable assembly is an RTB that plugs into the front of the IO module The other end has individually color-coded conductors that connect to a standard terminal block

Attribute 1756-TBNH 1756-TBSH 1756-TBCH 1756-TBS6H 1756-TBE

Description 20-position NEMA screw-clamp removable block

20-pin spring-clamp removable terminal block with standard housing

36-pin cage-clamp removable terminal block with standard housing

36-pin spring-clamp removable terminal block with standard housing

Extended depth terminal block housing

Screw torque 08hellip1 Nbullm7hellip9 lbbullin

04 Nbullm44 lbbullin

mdash

Screwdriver width 8 mm (516 in) max

IO Module

RTBPre-wired Cable

Factory-wired

Interface Module (IFM)

Field Wiring

14 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Integrated Motion

The Logix architecture supports motion control components that work in a wide variety of machine architectures

Integrated motion on EtherNetIP supports a connection to Ethernet drives

The Kinetix integrated-motion solution uses a SERCOS interface module to perform multi-axis synchronized motion

Logix integrated motion supports the analog family of servo modules for controlling drivesactuators

Networked motion provides the ability to connect via the DeviceNet network to a single axis drive to perform point-to-point indexing

For detailed specifications on motion interface modules see 1756 ControlLogix Integrated Motion Specifications publication 1756-TD004

For more information see these publications

Motion Analyzer CD to size your motion application and to make final component selection Download the software from httpwwwabcommotionsoftwareanalyzerhtml

Kinetix Motion Control Selection Guide publication GMC-SG001 to verify drive motor and accessory specifications

Integrated Motion on an EtherNetIP Network

Product Consideration

Drive that supports EtherNetIP connections Unlimited velocity torque and Vhz configured drives Kinetix 6500 drives PowerFlex 755 drives

ControlLogix controller As many as 100 drives per controller

ControlLogix EtherNetIP communication module 1hellip8 position configured drives with 1756-EN2TR module 1hellip255 position configured drives with 1756-EN3TR module

Publication 1756-SG001P-EN-P - May 2011 15

SERCOS Interface Modules

The SERCOS interface modules can connect to these servo drives

2093 Kinetix 2000 multi-axis servo drive 2094 Kinetix 6000 multi-axis servo drive 2099 Kinetix 7000 high-power servo drive 2098 Ultra3000 SERCOS servo drive

ControlLogix Controller

PanelView Plus Terminal

Workstations

POINT IO ModulesDrive with EtherNetIP Connection

Cat No Description Number of Axis

1756-M16SE Rockwell Automation SERCOS interface modules 16

1756-M08SE 8

1756-M03SE 3

1756-M08SEG SERCOS interface drives that are Extended Pack Profile compliant 8

16 Publication 1756-SG001P-EN-P - May 2011

Analog Motion Interface Modules

RSLogix 5000 Software1756-MxxSE Module

ControlLogix Controller

Three-phase Input Power

Line Interface Module

Integrated Axis Module

Motor Motor Feedback

Axis Modules

Slot Filler Module

Shunt Module

SERCOS Fiber-optic RingKinetix 6000 Multi-axis Servo Drive

Cat No Description Number of Axis

1756-M02AE Analog servo interface drives with quadrature feedback 2

1756-HYD02 Analog hydraulic servo interface drives LDT feedback 2

1756-M02AS Analog servo interface drives with SSI feedback 2

Publication 1756-SG001P-EN-P - May 2011 17

ControlLogix Communication Modules

Separate communication modules are available for different networks Install multiple communication modules into the ControlLogix backplane to bridge or route control and information data between different networks You can route a message through a maximum of four chassis (eight communication hops) You do not need a ControlLogix controller in the chassis

For detailed specifications see 1756 ControlLogix Network Specifications publication 1756-TD003

Application Network Page

Plant management (material handling) Configuration data collection and control on a single high-speed network Time-critical applications with no established schedule Inclusion of commercial technologies (such as video over IP) InternetIntranet connection Integrated CIP motion and safety

EtherNetIP network 19

High-speed transfer of time-critical data between controllers and IO devices Deterministic and repeatable data delivery Media redundancy Intrinsic safety Redundant controller systems

ControlNet network 20

Connections of low-level devices directly to plant floor controllers without interfacing them through IO modules

Data sent as needed More diagnostics for improved data collection and fault detection Less wiring and reduced start-up time than a traditional hard-wired system

DeviceNet network 21

Plant-wide and cell-level data sharing with program maintenance Data sent regularly Transfer of information between controllers

Data Highway Plus network 23

Connections between controllers and IO adapters Data sent regularly Distributed control so that each controller has its own IO and communicates with a

supervisory controller

Remote IO network 23

Fieldbus transmitters and actuators Closed-loop control Process automation

Foundation Fieldbus network 25

18 Publication 1756-SG001P-EN-P - May 2011

EtherNetIP Communication Modules

The Ethernet Industrial (EtherNetIP) network protocol is an open industrial-networking standard that supports both real-time IO messaging and message exchange The EtherNetIP network uses off-the-shelf Ethernet communication chips and physical media

Accessories - EtherNetIP Network

Cat No Description Media Communication Rate

CIP Motion Axes max

TCPIP Connections

Logix Connections

1756-EN2F EtherNetIP bridge fiber Fiber 100 Mbps 8 128 256

1756-EN2T EtherNetIP bridge copper Copper 10100 Mbps 8 128 256

1756-EN2TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 8 128 256

1756-EN3TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 255 128 256

1756-ENBT EtherNetIP bridge copper Copper 10100 Mbps mdash 64 128

1756-EWEB Ethernet web server module Copper 10100 Mbps mdash 64 128

1756-EN2TXT ControlLogix-XT extended temperature EtherNetIP bridge copper for extreme environments

Copper 10100 Mbps 8 128 256

Cat No Description Specifications

1585J-M8PBJM-x Ethernet RJ45 patchcordx = 2 (2 m) 5 (5 m) or 10 (10 m)

8-conductor Teal Riser PVC Cable (Flex Rated cable also available)

1585J-M8CC-H RJ45 insulation displacement connector (IDC) 01280325 mm2 (26hellip22 AWG) Cat 6 IDC no tool required

1585J-M8CC-C RJ45 crimp connector with boot qty = 50 pieces 01280205 mm2 (26hellip24 AWG Cat 5e requires crimp tool for assembly

1585A-Jcrimp Crimp tool mdash

9300-RADES Remote access dial-in kit 56 Kbps modem connection to devices on an Ethernet network includes pre-configured modem communication module DIN rail mounting hardware associated cables

Publication 1756-SG001P-EN-P - May 2011 19

Example Configuration - EtherNetIP Network

ControlNet Communication ModulesThe ControlNet network combines the functionality of an IO network and a peer-to-peer network providing high-speed performance The ControlNet network provides deterministic repeatable transfers of critical control data

FirewallRouter

Stratix Switch

Stratix Switch

Stratix Switch

Powermonitor 3000PowerFlex 70

Ethernet PLC-5

MicroLogix

Ethernet SLC 500

1756 IO

1794 IO

1761-NET-ENI

ControlNet

DeviceNet

1734 IO

RSLinxPanelView Plus

1769-L35E CompactLogix

Cat No Description Communication Rate

Logix Connections Number of Nodes

1756-CN2B ControlNet bridge standard media 5 Mbps 128(1) 99

1756-CN2RB ControlNet bridge redundant media 5 Mbps 128(1) 99

1756-CNB ControlNet bridge standard media 5 Mbps 64(2) 99

1756-CNBR ControlNet bridge redundant media 5 Mbps 64(2) 99

1756-CN2RXT ControlLogix-XT extended temperature ControlNet bridge redundant media

5 Mbps 128(1) 99

(1) 128 connections are available for standard use An additional three connections are reserved for redundant control

(2) Recommend using only 4048 Logix connections for IO

20 Publication 1756-SG001P-EN-P - May 2011

Example Configuration - ControlNet Network

Example Configuration - Redundant ControlNet Media

For information on ControlNet media see ControlNet Media System Components List AG-PA002

DeviceNet Communication Module

The DeviceNet network provides connections between simple industrial devices (such as sensors and actuators) and higher-level devices (such as controllers and computers)

1784-U2CNPanelView Plus

1788-CN2DN

DeviceNetPowerFlex 700SPLC-540CControlLogix

Redundant Media

ControlLogix1756-CNBR

ControlNet Node

ControlNet Node

Cat No Description Communication Rate Number of Nodes

1756-DNB DeviceNet bridge 125 Kbps (500 m max)250 Kbps (250 m max)500 Kbps (100 m max)

64

Publication 1756-SG001P-EN-P - May 2011 21

Example Configuration - DeviceNet Network

Accessories - DeviceNet Network

PLC-51771-SDN ControlLogix

1756-DNB

Ultra3000

PanelView Plus1784-U2DN

Ultra5000

IO

Motor starter

PowerFlex AC

Sensor Pushbuttons

LightsBar Code Scanner

Cat No Description

KwikLink Lite flat media KwikLink Lite flat media is a newer ODVA-approved solution for wiring DeviceNet networks Drop-lines for connecting nodes are added by using the KwikLink Lite two-piece connectors This cable system supports the intermixing of DeviceNet cable types (thin-round with flat) All of the KwikLink Lite connectors provide insulation displacement technology with reduced assembly time

KwikLink flat media The KwikLink flat media system provides a modular cabling method with its flat 4-wire cable and insulation displacement connectors (IDCs) The KwikLink system allows nodes to be added to the network without severing the trunkline Cutting or stripping of the trunkline is eliminated as is the need for predetermined cable lengths

Round media Round trunk cable is available in bulk spools or as pre-molded cordsets or patchcords in varying lengths A wide variety of rugged durable DeviceNet components is available for use in round trunk systems Stainless steel versions of round cable system components are also available Thick-trunk round media systems use thick cable for maximum DeviceNet trunk line length Round media thin-trunk systems use thin cable to reduce maximum trunk line distances with a more

compact and cost-effective installation for some applications Thin-cable outer jacket material is TPE for additional chemical resistance

22 Publication 1756-SG001P-EN-P - May 2011

Data Highway Plus and Remote IO Communication Modules

The Data Highway Plus network supports messaging between devices The remote IO link connects to remote IO chassis and other intelligent devices

The 1756-DHRIO module supports messaging between devices on DH+ networks The remote IO functionality enables the module to act as a scanner for transferring digital and block-transfer data to and from remote IO devices

The 1756-RIO module can act as a scanner or adapter on a remote IO network In addition to digital and block-transfer data the 1756-RIO module transfers analog and specialty data without message instructions

Cat No Description Communication Rate DH+ Connections RIO Connections Maximum Recommended Logix Connections

1756-DHRIO Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

1756-RIO Remote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

mdash Remote IO scanner or adapter32 physical racks (076) any combination of rack size and block transfers

10 scheduled IO

1756-DHRIOXT ControlLogix-XT extended temperature Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

Publication 1756-SG001P-EN-P - May 2011 23

Example Configuration - DH+ Network

Example Configuration - Remote IO Network

Accessories - DH+ and Remote IO Networks

PanelView Plus

PLC-5 1784-U2DHPRSLogix 5000

ControlLogix1756-DHRIO

SLC 504

PanelView PlusPLC-5

1791 IO1794 IO

1756-RIO as a Remote IO Adapter

1756-DHRIO as a Remote IO Scanner

Cat No Description Specifications

1770-CD Cable to connect communication module to DH+ network Belden 9463 twinaxial

9300-RADKIT Remote access dial-in kit 56 Kbps modem connection to devices on a DH+ network includes pre-configured modem communication module DIN rail mounting hardware associated cables

24 Publication 1756-SG001P-EN-P - May 2011

FOUNDATION Fieldbus Linking Devices

The FOUNDATION Fieldbus protocol is a network designed for distributed control of process applications

Example Configuration - Bridge to EtherNetIP Network

Cat No Description Communication Rate Number of H1 Ports

Devices per H1 Link

Devices per Linking Device

1757FFLD2 FOUNDATION Fieldbus bridge to an Ethernet network

FOUNDATION Fieldbus 3125 KbpsEtherNetIP 10100 Mbps

2 16(8hellip10 recommended)

32

1757-FFLD4 4 64

1757-FFLDC2 FOUNDATION Fieldbus bridge to a ControlNet network

FOUNDATION Fieldbus 3125 KbpsControlNet 5 Mbps

2 16(8hellip10 recommended)

32

1757-FFLDC4 4 64

FactoryTalk View SERSFieldbusRSLogix 5000

1757-FFLD4

H1(1)

H1(2)H1(3)H1(4)

HSEIP

Publication 1756-SG001P-EN-P - May 2011 25

Example Configuration - Bridge to ControlNet Network

Other Connectivity Options

ControlLogix RedundancyFactoryTalk View SERSFieldbusRSLogix 5000

ControlNet Redundant Media

1757-FFLDC2

FF H1

EtherNetIP

Option Consideration

USB connection The 1756-L7x controller has a USB port in place of the serial port If your application requires RS-232 functionality see the many Encompass partners at httpwwwrockwellautomationcomencompass

Serial connection The serial port on the 1756-L6x controller is compatible with RS-232 serial communication The serial port supports the DF1 protocol to communicate with other devices on the serial linkTo use Logix5000 controllers on Modbus you connect through the serial port and execute a specific ladder logic routine The controller project is available with RSLogix 5000 Enterprise programming software For more information see Using Logix5000 Controllers as Masters or Slaves on Modbus Application Solution publication CIG-AP129

DH-485 network The controller serial port is compatible with DH-485 communication The DH-485 connection does support remote programming and monitoring via RSLogix 5000 softwareOr add a DH-485 communication bridge module (cat no 1756-DH485)

SynchLink network The SynchLink communication module (1756-SYNCH) provides time synchronization and data broadcasting capabilities for distributed motion and coordinated drive control The module connects a ControlLogix chassis to a SynchLink fiber-optic communication link

26 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Controllers The ControlLogix controller provides a scalable controller solution that is capable of addressing a large amount of IO points

The controller can be placed into any slot of a ControlLogix chassis and multiple controllers can be installed in the same chassis Multiple controllers in the same chassis communicate with each other over the backplane (just as controllers can communicate over networks) but operate independently

ControlLogix controllers can monitor and control IO across the ControlLogix backplane as well as over IO links ControlLogix controllers can communicate over EtherNetIP ControlNet DeviceNet DH+ Remote IO and RS-232-C (DF1DH-485 protocol) networks and many third party process and device networks To provide communication for a ControlLogix controller install the appropriate communication interface module into the chassis

For detailed specifications see 1756 ControlLogix Controllers Specifications publication 1756-TD001

Cat No Description User Memory

1756-L72 ControlLogix controller 1 built-in USB port 4 MB

1756-L73 8 MB

1756-L74 16 MB

1756-L75 32 MB

1756-L61 ControlLogix controller 1 built-in RS-232 port 2 MB

1756-L62 4 MB

1756-L63 8 MB

1756-L64 16 MB

1756-L65 32 MB

1756-L61S GuardLogix safety controller 2 MB standard1 MB safety

1756-L62S 4 MB standard1 MB safety

1756-L63S 8 MB standard375 MB safety

1756-LSP GuardLogix safety partner (one is required for each GuardLogix controller) mdash

1756-L63XT ControlLogix-XT controller extreme environment 8 MB

IMPORTANT Scan time for a project loaded in a 1756-L64 or 1756-L65 controller may be slower than for the same project loaded in one of the other 1756-L6x controllers See the Logix5000 Controllers Instruction Execution Time and Memory Use Reference Manual publication 1756-RM087 for instruction execution times

Publication 1756-SG001P-EN-P - May 2011 27

Standard ControlLogix Controllers

The ControlLogix controller is part of the Logix5000 family of controllers A ControlLogix system includes the following

The ControlLogix controller available in different combinations of user memory

RSLogix 5000 programming software 1756 ControlLogix IO modules that reside in a 1756 chassis Separate communication modules for network communication

Features - Standard ControlLogix Controllers

Feature 1756-L61 1756-L62 1756-L63 1756-L64 1756-L65

1756-L72 1756-L73 1756-L74 1756-L75

Controller tasks 32 tasks 100 programstask Event tasks all event triggers

Built-in communication ports 1 port RS-232 serial 1 port USB

Communication options EtherNetIP ControlNet DeviceNet Data Highway Plus Remote IO SynchLink Third-party process and device networks

Built-in port Serial USB

Controller connections supported max 250 500

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Full support

Integrated motion EtherNetIP connection SERCOS interface Analog options (encoder input LDT input SSI input)

Programming languages Relay ladder Structured text Function block SFC

28 Publication 1756-SG001P-EN-P - May 2011

GuardLogix Controllers

A GuardLogix controller is a ControlLogix controller that also provides safety control The GuardLogix system is a dual controller solutionmdashyou must use a 1756-L6xS primary controller and a 1756-LSP safety partner to achieve SIL 3CAT 4

During development safety and standard have the same rules multiple programmers online editing and forcing are all allowed Once the project is tested and ready for final validation you set the Safety Task to a SIL 3 integrity level which is then enforced by the GuardLogix controller When safety memory is locked and protected the safety logic cant be modified and all safety functions operate with SIL 3 integrity On the standard side of the GuardLogix controller all functions operate like a regular Logix controller

Use Guard IO modules for field device connectivity on Ethernet or DeviceNet networks and for safety interlocking between GuardLogix controllers use Ethernet or ControlNet networks Multiple GuardLogix controllers can share safety data for zone to zone interlocking or a single GuardLogix controller can use remote distributed safety IO between different cellsareas

In addition to the standard features of a ControlLogix controller the GuardLogix controller has these safety-related features

Application Description

SIL 1 2 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508 and applications up to and including PLeCat4 according to ISO 13849-1 For more information see GuardLogix Controllers Systems Safety Reference Manual publication 1756-RM093 GuardLogix Controllers User Manual publication 1756-UM020 GuardLogix Safety Application Instruction Set Reference Manual publication 1756-RM095

Features - GuardLogix Controllers

Feature 1756-L61S 1756-L62S 1756-L63S 1756-LSP

Safety communication options Standard and safety EtherNetIP ControlNet DeviceNet

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Not supported

Programming languages Relay ladder

Publication 1756-SG001P-EN-P - May 2011 29

ControlLogix-XT Controllers

The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh corrosive environments

When used with FLEX IO-XT products the ControlLogix-XT system can withstand temperatures range from -2070 C (-4158 F)

When used independently the ControlLogix-XT system can withstand temperature ranges from -2570 C (-13158 F)

Redundant ControlLogix Controllers

The ControlLogix controller supports controller redundancy In a redundant controller system you need these components

Two 1756 chassis each with the following the same ndash Number of slots

ndash Modules in the same slots

ndash Redundancy firmware revisions in each module

ndash Two additional ControlNet nodes outside the redundant chassis pair

You need one of these redundancy modules

One 1756-RM module per chassis that supports the followingndash Two 1756-L61 1756-L62 1761-L63 controllers or one 1756-L64

controller

ndash Maximum of seven communication modules which can be 1756-CN2 series B 1756-CN2R series B and 1756-EN2T modules

ndash One 1756-RMCx cable

One 1757-SRM module per chassis that supports the followingndash One 1756-L61 1756-L62 1756-L63 1756-L64 controller

ndash Maximum of seven communication modules which can be 1756-CNB series D or E 1756-CNBR series D or E 1756-ENBT and 1756-EWEB modules

ndash One 1757-SRCx cable

30 Publication 1756-SG001P-EN-P - May 2011

Accessories - Controllers

Memory Cards

Memory cards offer nonvolatile memory to permanently store a user program and tag data on a controller The 1756-L7x ControlLogix controller comes with 1784-SD1 Secure Digital (SD) card already installed The 1756-L6x controllers support optional CompactFlash cards that you purchase separately The memory card installs in a socket on the controller Through RSLogix 5000 software you can manually trigger the controller to save to or load from nonvolatile memory or configure the controller to load from nonvolatile memory on powerup

The GuardLogix controller does not support user program storage or retrieval by using a CompactFlash card

1756 Energy Storage Modules

Instead of a battery the 1756-L7x controller ships with a 1756-ESMCAP energy storage module (ESM) already installed

Attribute 1784-CF64 1784-CF128 1784-SD1 1784-SD2

Memory 64 MB 128 MB 1 GB 2 GB

Supported controllers 1756-L6x 1756-L7x

Weight approx 142 g (05 oz) 176 g (0062 oz)

Cat No Description

1756-ESMCAP Capacitor-based energy-storage module Comes with the controller

1756-EMNSE ESM without WallClockTime backup power Additionally you can use this ESM with a 1756-L73 (8 MB) or smaller memory-sized controller only

Use this ESM if your application requires that the installed ESM deplete its residual energy to 40 microJoule or less before transporting it into or out of your application

1756-ESMNRM Energy-storage module that secures the controller by preventing the USB connection and SD card useThis ESM provides your application an enhanced degree of security

Publication 1756-SG001P-EN-P - May 2011 31

1756 ControlLogix Batteries

Each 1756-L6x controller ships with a battery With a memory card installed the controller can be used without a battery If you do not use a battery current tag data will be at the state it was when the memory card was saved

ControlLogix Chassis The ControlLogix system is a modular system that requires a 1756 IO chassis Place any module into any slot The backplane provides a high-speed communication path between modules

All of the chassis are designed for horizontal-only back-panel mounting The chassis are available in these configurations

Standard chassis ControlLogix-XT chassis

For detailed specifications see 1756 ControlLogix Chassis Specifications Specifications publication 1756-TD006

Features - Chassis

Slot guides and snap-in retention for easy and secure module fit for any type of 1756 module

Direct mounting accommodates any 1756 power supply

Attribute 1756-BA1 1756-BA2 1756-BATM(1) 1756-BATA

Description Lithium battery (059 g) Lithium battery (059 g) Externally mounted battery assembly

Replacement lithium battery for 1756-BATM (5 g max lithium per each D cell contains 2 D cells)

ControlLogix controllers 1756-L61 1756-L62 1756-L63 series A

1756-L61 1756-L62 1756-L63 series B1756-L64 1756-L65

1756-L61 1756-L62 1756-L63 series A

1756-BATM battery module

GuardLogix controllers mdash 1756-L61S 1756-L62S 1756-L63S

mdash mdash

ControlLogix-XT controllers

mdash 1756-L63XT mdash mdash

(1) The 1756-BATM externally mounted battery assembly is highly recommended for use with all series A 1756-L6x controllers and provides longer battery life than the 1756-BA1 battery The 1756-BATM includes one 1756-BATA lithium battery assembly and a 1 m (328 ft) cable to connect housing to controller

32 Publication 1756-SG001P-EN-P - May 2011

Standard Chassis

The chassis backplane provides a high-speed communication path between modules and distributes power to each of the modules within the chassis

ControlLogix-XT Chassis

The ControlLogix-XT chassis support extreme temperature environments

Accessories - Chassis

Use a slot filler module to fill empty slots

Cat No Description Slots

1756-A4 ControlLogix standard chassis 4

1756-A7 7

1756-A10 10

1756-A13 13

1756-A17 17

Cat No Description Slots Temperature Range

1756-A4LXT ControlLogix-XT chassis 4 -2560 degC (-13140 degF)

1756-A5XT 5 -2570 degC (-13158 degF)

1756-A7LXT 7 -2560 degC (-13140 degF)

Cat No Description

1756-N2 Slot filler module for empty slots in standard ControlLogix chassis

1756-N2XT Slot filler module for empty slots in ControlLogix-XT chassis

Publication 1756-SG001P-EN-P - May 2011 33

ControlLogix Power Supplies

ControlLogix power supplies are used with the 1756 chassis to provide 12V 33V 5V and 24V DC power directly to the chassis backplane Select from these configurations

Standard power Redundant power ControlLogix-XT power

For detailed specifications see 1756 ControlLogix Power Supplies Specifications publication 1756-TD005

Standard Power Supplies

You mount a standard power supply directly on the left end of the chassis where it plugs directly into the backplane

ControlLogix-XT Power Supplies

The ControlLogix-XT power supplies support extreme temperature environments

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA72 ControlLogix standard AC 120V220V AC 85hellip265V AC Standard series A and series B

1756-PA75 120V220V AC 85hellip265V AC Standard series B

1756-PB72 ControlLogix standard DC 24V DC 18hellip32V DC Standard series A and series B

1756-PB75 24V DC 1832V DC Standard series B

1756-PC75 48V DC 30hellip60V DC Standard series B

1756-PH75 125V DC 90hellip143V DC Standard series B

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PAXT ControlLogix-XT AC power supply 85265V AC 120240V AC XT

1756-PBXT ControlLogix-XT DC power supply 24V DC 18hellip32V DC XT

34 Publication 1756-SG001P-EN-P - May 2011

Redundant Power Supplies

To build a redundant power supply system you need the following

Two redundant power supplies (both 1756-PA75R or 1756-PB75R) One 1756-PSCA2 chassis adapter module Two 1756-CPR2 cables to connect the power supplies to the

1756-PSCA2 chassis adapter module (091 m (3 ft) length) User-supplied annunciator wiring to connect the power supplies to the

input modules as needed

The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Accessories - Redundant Power Supplies

Visualization Products Visualization products together with Logix for control and NetLinx architecture for communication make up the Rockwell Automation Integrated Architecture strategy The visualization strategy combines Rockwell Automation expertise in Allen-Bradley electronic operator interface and industrialized personal computer hardware with Rockwell Software supervisory control software Current visualization products include the following

FactoryTalk View software PanelView Plus operator interface PanelView Plus CE operator interface Industrial computers and monitors

For more information see the Operator Interface catalog pages at httpwwwabcomenepubcatalogs1276221813761239781

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA75R ControlLogix redundant 120V220V AC 85hellip265V AC Standard series B

1756-PB75R 24V DC 192hellip32V DC Standard series B

Cat No Description Specifications

1756-PSCA2 Chassis adapter module Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Mounts directly to left side of 1756 chassis

1756-CPR2 Chassis adapter cable Connects redundant power supply to 1756-PCSA2 chassis adapter Length091 m (3 ft)

Publication 1756-SG001P-EN-P - May 2011 35

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR ltFEFF004200720075006b00200064006900730073006500200069006e006e007300740069006c006c0069006e00670065006e0065002000740069006c002000e50020006f0070007000720065007400740065002000410064006f006200650020005000440046002d0064006f006b0075006d0065006e00740065007200200066006f00720020007500740073006b00720069006600740020006100760020006800f800790020006b00760061006c00690074006500740020007000e500200062006f007200640073006b0072006900760065007200200065006c006c00650072002000700072006f006f006600650072002e0020005000440046002d0064006f006b0075006d0065006e00740065006e00650020006b0061006e002000e50070006e00650073002000690020004100630072006f00620061007400200065006c006c00650072002000410064006f00620065002000520065006100640065007200200035002e003000200065006c006c00650072002000730065006e006500720065002egt PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

2 Rockwell Automation Publication 1756-SG001P-EN-P - May 2011

Logix Controllers ComparisonCharacteristic 1756 ControlLogix 1756 GuardLogix 1768

CompactLogix1768 Compact GuardLogix

1769-L3x CompactLogix

1769-L23x CompactLogix

1789 SoftLogix5800

Controller tasksbull Continuousbull Periodicbull Event

bull 32 tasksbull 100 programstaskbull Event tasks all event triggers

bull 32 tasksbull 100 programstaskbull Event tasks all event triggers

bull 16 tasksbull Event tasks consumed tag EVENT instruction axis and motion event triggers

bull 16 tasksbull Event tasks consumed tag EVENT instruction axis and motion event triggers

bull 1769-L35x 8 tasksbull 1769-L32x 6 tasksbull 1769-L31 4 tasksbull Event tasks consumed tag and EVENT instruction triggers

bull 3 tasksbull 16 programstaskbull Event tasks consumed tag and EVENT instruction triggers

bull 32 tasksbull 100 programstaskbull Event tasks all event triggers plus outbound and Windows events

User memory 1756-L61 2 MB1756-L62 4 MB1756-L63 8 MB1756-L64 16 MB1756-L65 32 MB

1756-L72 4 MB1756-L73 8 MB1756-L74 16 MB1756-L75 32 MB

1756-L61S2 MB Standard1 MB Safety

1756-L62S4 MB Standard1 MB Safety

1756-L63S8 MB Standard375 MB Safety

1768-L43 2 MB1768-L45 3 MB

1768-L43S2 MB Standard05 MB Safety

1768-L45S3 MB Standard1 MB Safety

1769-L31 512 KB1769-L32x 750 KB1769-L35x 15 MB

512 KB 1789-L102 MB 1 controller no motion

1789-L3064 MB 3 controllers

1789-L6064 MB 6 controllers

Nonvolatile user memory

1756-L6x CompactFlash

1756-L7xSecure Digital card

CompactFlash CompactFlash CompactFlash CompactFlash None None

Built-in communication ports

1756-L6x 1 port RS-232 serial

1756-L7x 1 port USB

1 port RS-232 serial 1 port RS-232 serial 1 port RS-232 serial bull 1769-L31 2 RS-232 portsbull 1769-L32C 1769-L35CR 1 ControlNet port and 1 RS-232 serial portbull 1769-L32E 1769-L35E 1 EtherNetIP port and 1 RS-232 serial port

bull 1769-L23E-QB1B 1 EtherNetIP port and 1 RS-232 serial portbull 1769-L23E-QBFC1B 1 EtherNetIP port and 1 RS-232 serial portbull 1769-L23-QBFC1B 2 RS-232 serial ports

Depends on personal computer

Communication options bull EtherNetIPbull ControlNetbull DeviceNetbull Data Highway Plusbull Remote IObull SynchLink

bull EtherNetIP (standard and safety)bull ControlNet (standard and safety)bull DeviceNet (standard and safety)bull Data Highway Plusbull Remote IObull SynchLink

bull EtherNetIPbull ControlNetbull DeviceNet

bull EtherNetIP (standard and safety)bull ControlNet (standard and safety)bull DeviceNet (standard)

bull EtherNetIPbull ControlNetbull DeviceNet

bull EtherNetIPbull DeviceNet

bull EtherNetIPbull ControlNetbull DeviceNet

Controller connections 1756-L6x 250

1756-L7x 500

250 250 250 100 100 250

Network connections Per network modulebull 100 ControlNet (CN2A)bull 40 ControlNet (CNB)bull 256 EtherNetIP 128 TCP (EN2x)bull 128 EtherNetIP 64 TCP (ENBT)

Per network modulebull 100 ControlNet (CN2A)bull 40 ControlNet (CNB)bull 256 EtherNetIP 128 TCP (EN2x)bull 128 EtherNetIP 64 TCP (ENBT)

Per network modulebull 48 ControlNetbull 128 EtherNetIP 64 TCP

Per network modulebull 48 ControlNetbull 128 EtherNetIP 64 TCP

Per controllerbull 32 ControlNetbull 32 EtherNetIP 32 TCP

Per controllerbull 32 EtherNetIP 8 TCP

Per network modulebull 48 ControlNetbull 128 EtherNetIP 64 TCP

Controller redundancy Full support None Backup via DeviceNet

Backup via DeviceNet

Backup via DeviceNet

Backup via DeviceNet NA

Simple motion bull Stepperbull Servo via DeviceNetbull Analog or networked AC drive

bull Stepperbull Servo via DeviceNetbull Analog or networked AC drive

bull Stepperbull Servo via DeviceNetbull Analog or networked AC drive

bull Stepperbull Servo via DeviceNetbull Analog or networked AC drive

bull Stepperbull Servo via DeviceNetbull Analog or networked AC drive

bull Stepperbull Servo via DeviceNetbull Analog or networked AC drive

bull Stepperbull Servo via DeviceNetbull Analog or networked AC drive

Integrated motion EtherNetIPSERCOS interfaceAnalog optionsbull Encoder inputbull LDT inputbull SSI input

EtherNetIPSERCOS interfaceAnalog optionsbull Encoder inputbull LDT inputbull SSI input

SERCOS interface SERCOS interface NA NA SERCOS interfaceAnalog encoder input

Programming languages

bull Relay ladderbull Structured textbull Function blockbull Sequential function chart

bull Standard task all languagesbull Safety task relay ladder safety application instructions

bull Relay ladderbull Structured textbull Function blockbull Sequential function chart

bull Standard task all languagesbull Safety task relay ladder safety application instructions

bull Relay ladderbull Structured textbull Function blockbull Sequential function chart

bull Relay ladderbull Structured textbull Function blockbull Sequential function chart

bull Relay ladderbull Structured textbull Function blockbull Sequential function chartbull External routines (developed in CC++)

Select a ControlLogix System

Step 1ControlLogix IO Modules

Step 2ControlLogix Integrated Motion

Step 3ControlLogix Communication Modules

1756 ControlLogix System

Step 4ControlLogix Controllers

Step 5ControlLogix Chassis

Step 6ControlLogix Power Supplies

Select IO modules - some modules have field-side

diagnostics electronic fusing or individually isolated inputsoutputs

A remote terminal block (RTB) or wiring system for each IO module

Select A SERCOS or analog interface module

Associated cables

A removable terminal block (RTB) - only for analog interface modules

Select drives motors and accessories (use the Motion Analyzer software)

Select Networks

Communication modules

Associated cables and network equipment

Sufficient modules and cables if you are planning a redundant system

Select A controller with sufficient memory

Secure Digital or CompactFlash card

Replacement batteries if needed

Select A chassis with sufficient slots

Slot fillers for empty slots

Select One power supply for each chassis if you are using

standard power supplies

A power supply bundle if you are planning a redundant power supply system

Optional StepProgramming Software

Optional StepVisualization Products

Page 8

Page 15

Page 18

Page 27

Page 32

Page 34

Page 35 Page 36

3Publication 1756-SG001P-EN-P - May 2011 3

ControlLogix System Overview

The ControlLogix system provides discrete drives motion process and safety control together with communication and state-of-the-art IO in a small cost-competitive package The system is modular so you can design build and modify it efficiently with significant savings in training and engineering

Example Configuration - ControlLogix System

A simple ControlLogix system consists of a standalone controller and IO modules in a single chassis For a more comprehensive system use the following

Multiple controllers in a single chassis Multiple controllers joined across networks IO in multiple platforms that are distributed in many locations and

connected over multiple IO links

RUN IO

RS232

OK

FORCE

BAT

RUN REM PROG

Logix5564

OKCP

SERCOS

OKAB

OKIOMODNET OKIOMODNET

ST

ST

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

HART

ANALOG INPUT

OK

DIAGNOSTIC

FLT

ST

FLT

ST

0 1 2 3 4 5 6 7

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

8 9 10 11 12 13 14 15

DC OUTPUT

DIAGNOSTIC

FLT

ST

FLT

ST

0 1 2 3 4 5 6 7

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

8 9 10 11 12 13 14 15

DC INTPUT

POWER

STATUS

WDOG

BATT

NS

MODE

H1-1H1-2H1-3H1-4

DANGERDANGERDANGERDANGER

755

98

2

5

0

3

6

7

1

4

Logix55LSP

SAFETY

RUN

SAFETY

TASK

BAT OK

RUN IO

RS232

OK

FORCE

BAT

RUN REM PROG

Logix5561

Plant MRP SystemDatabaseTracking Systems

Laptop

Stratix 8000

POINT Guard IO

FLEX IO

PanelView Plus

PowerFlex 755

CompactBlock Guard IO

PowerFlex 70

Other Devices

EtherNetIP

Kinetix Servo Drive

Motor Feedback

Servo Motor

Motor Power

DeviceNet

FLEX IO-XT

Tower LightArmorBlock Guard IO

PowerFlex 70

Valve

Guard IO

HART

ControlNet

Flowmeter

LevelFoundation Fieldbus

1756

-L61

S17

56-L

SP17

56-L

64SE

RCOS

1756

-EN

2T17

56-C

N2

1756

-DN

BIO IO An

alog

4 Publication 1756-SG001P-EN-P - May 2011

ControlLogix-XT System

The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh corrosive environments

When used with FLEX IO-XT products the ControlLogix-XT system can withstand temperatures range from -2070 C (-4158 F)

When used independently the ControlLogix-XT system can withstand temperature ranges from -2570 C (-13158 F)

GuardLogix Safety System

A GuardLogix controller is a ControlLogix controller that also provides safety control The GuardLogix system is a dual controller solution mdash you must use a 1756-L6xS primary controller and a 1756-LSP safety partner to achieve SIL 3CAT 4 A major benefit of this system is that itrsquos still a single project safety and standard together The safety partner controller is a part of the system is automatically configured and requires no user setup

Application Description

SIL 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508 and applications up to and including category (CAT) 4 according to EN954-1 For more information see the following GuardLogix Controllers Systems Safety Reference Manual publication 1756-RM093 GuardLogix Controllers User Manual publication 1756-UM020 GuardLogix Safety Application Instruction Set Reference Manual publication 1756-RM095

SIL 2 Components of the ControlLogix system are type-approved and certified for use in SIL 2 applications according to IEC 61508 and AK4 applications according to DIN V19250 For a list of ControlLogix system components that meet SIL 2 requirements see Using ControlLogix in SIL 2 Applications Safety Reference Manual publication 1756-RM001

Publication 1756-SG001P-EN-P - May 2011 5

Example Configuration - Redundant ControlLogix System

The ControlLogix controller supports controller redundancy

OKAB

AB

DIAGNOSTIC

FLT

ST

FLT

ST

0 1 2 3 4 5 6 7

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

8 9 10 11 12 13 14 15

DC INTPUT

DIAGNOSTIC

FLT

ST

FLT

ST

0 1 2 3 4 5 6 7

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

8 9 10 11 12 13 14 15

DC OUTPUT

ST

ST

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

HART

ANALOG INPUT

OK

DIAGNOSTIC

FLT

ST

FLT

ST

0 1 2 3 4 5 6 7

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

8 9 10 11 12 13 14 15

DC INTPUT

DIAGNOSTIC

FLT

ST

FLT

ST

0 1 2 3 4 5 6 7

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

8 9 10 11 12 13 14 15

DC OUTPUT

ST

ST

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

HART

ANALOG INPUT

OK

POWER

OKAB

AB

OKCOMMPRI

REDUNDANCY MODULE

RUN IO

RS232

OK

FORCE

BAT

RUN REM PROG

Logix5564

RUN IO

RS232

OK

FORCE

BAT

RUN REM PROG

Logix5562

OKNETLINK

POWERPOWER

POWER

OKAB

AB

OKCOMMPRI

REDUNDANCY MODULE

RUN IO

RS232

OK

FORCE

BAT

RUN REM PROG

Logix5564

RUN IO

RS232

OK

FORCE

BAT

RUN REM PROG

Logix5562

OKNETLINK

ESC SEL

EOI or HMI

EtherNetIP or ControlNet

1756-RM

1756-EN2T

1756-CN2RB1756-RM

1756-L61 1756-L62 or 1756-L63

1756-EN2T

1756-CN2RB

Primary ControlLogix Chassis Secondary ControlLogix Chassis

Fiber Optic Cable

FLEX IO

1203-CN1

1336 Plus II AC Drive

1756-CNBR

1756-PA75R or 1756-PB75R Redundant Power Supplies Redundant ControlNet

ControlLogix IO1756-PSCA2 Chassis Adapter

1756-CPR2 Cables

1756-L61 1756-L62 or 1756-L63

6 Publication 1756-SG001P-EN-P - May 2011

Example Configuration - Redundant IO System

The 1715 redundant IO system lets a ControlLogix controller communicate to a remote redundant IO chassis over an EtherNetIP network The 1715 redundant IO system provides fault tolerance and redundancy for critical processes by using a redundant adapter pair and multiple IO modules that have diagnostics

The redundant IO system must be connected to a ControlLogix system via an EtherNetIP network All connections are established via the Ethernet network by using the topologies supported by the 1756-EN2TR communication bridge

For detailed specifications see the 1715 Redundant IO System Specifications Technical Data publication 1715-TD001A-EN-P

1756

-RM

1756

-EN

2TR

IO B

ASE

1715

-A31

0

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

IO B

ASE

1715

-A31

0

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

1715

-AEN

TR

1756

-EN

2TR

1756

-RM

1715

-AEN

TR

1715

-IO

1715

-IO

1715

-IO

1715

-IO

1715

-IO

1715

-IO

ControlLogix Primary Chassis ControlLogix Secondary Chassis

1715 Redundant IO System

Publication 1756-SG001P-EN-P - May 2011 7

ControlLogix IO Modules The ControlLogix architecture provides a wide range of input and output modules to span many applications from high-speed digital to process control The ControlLogix architecture uses a producerconsumer model so that input information and output status can be shared among multiple controllers

Each ControlLogix IO module mounts in a ControlLogix chassis and requires either a removable terminal block (RTB) or a 1492 interface module (IFM) to connect all field-side wiring RTBs and IFMs are not included with the IO modules They must be ordered separately

For detailed specifications see 1756 ControlLogix IO Modules Specifications publication 1756-TD002

AC Digital put Modules

AC Digital Output Modules

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

1756-IA8D 8 diagnostic inputs(4 pointsgroup)

120V AC 79hellip132V AC 1756-TBNH1756-TBSH

1756-IA16 16 inputs(8 pointsgroup)

120V AC 74hellip132V AC 1756-TBNH1756-TBSH

1756-IA16I 16 individually isolated inputs 120V AC 74hellip132V AC 1756-TBCH1756-TBS6H

1756-IA32 32 diagnostic inputs(4 pointsgroup)

120V AC 74hellip132V AC 1756-TBCH1756-TBS6H

1756-IM16I 16 individually isolated inputs 240V AC 159hellip265V AC 1756-TBCH1756-TBS6H

1756-IN16 16 inputs(8 pointsgroup)

24V AC 10hellip30V AC 1756-TBNH1756-TBSH

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

1756-OA8 8 outputs(4 pointsgroup)

120240V AC 79hellip265V AC 1756-TBNH1756-TBSH

1756-OA8D 8 diagnostic electronically fused outputs(4 pointsgroup)

120V AC 74hellip132V AC 1756-TBNH1756-TBSH

1756-OA8E 8 electronically fused outputs(4 pointsgroup)

120V AC 74hellip132V AC 1756-TBNH1756-TBSH

1756-OA16 16 mechanically fusedgroup outputs(8 pointsgroup)

120240V AC 74hellip265V AC 1756-TBNH1756-TBSH

1756-OA16I 16 individually isolated outputs

120240V AC 74hellip265V AC 1756-TBCH1756-TBS6H

1756-ON8 8 outputs(4 pointsgroup)

24V AC 10hellip30V AC current gt50 mA16hellip30V AC current lt50 mA

1756-TBNH1756-TBSH

8 Publication 1756-SG001P-EN-P - May 2011

DC Digital Input Modules

DC Digital Output Modules

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

1756-IB16 16 inputs(8 pointsgroup)

1224V DC sink 10312V DC 1756-TBNH1756-TBSH

1756-IB16D 16 diagnostic inputs(4 pointsgroup)

1224V DC sink 1030V DC 1756-TBCH1756-TBS6H

1756-IB16I 16 individually isolated inputs 1224V DC sinksource 1030V DC 1756-TBCH1756-TBS6H

1756-IB16ISOE 16 individually isolated sequence of events inputs

2448V DC sinksource 1055V DC 1756-TBCH1756-TBS6H

1756-IB32 32 inputs(16 pointsgroup)

1224V DC sink 10312V DC 1756-TBCH1756-TBS6H

1756-IC16 16 inputs(8 pointsgroup)

48V DC sink 3055V DC 60 degC (140 degC)3060V DC 55 degC (131 degC)

1756-TBNH1756-TBSH

1756-IG16 16 inputs(8 pointsgroup)

5V DC TTL source (Low=True)

4555V DC 1756-TBNH1756-TBSH

1756-IH16I 16 individually isolated inputs 125V DC sinksource 90146V DC 1756-TBCH1756-TBS6H

1756-IH16ISOE 16 individually isolated sequence of events inputs

125V DC sinksource 90140V DC 1756-TBCH1756-TBS6H

1756-IV16 16 inputs(8 pointsgroup)

1224V DC source 1030V DC 1756-TBNH1756-TBSH

1756-IV32 32 inputs(16 pointsgroup)

1224V DC source 1030V DC 1756-TBCH1756-TBS6H

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

1756-OB8 8 outputs 1224V DC source 1030V DC 1756-TBNH1756-TBSH

1756-OB8EI 8 electronically fused individually isolated outputs

1224V DC source 1030V DC 1756-TBCH1756-TBS6H

1756-OB8I 8 individually isolated outputs 1224V DC source 1030V DC 1756-TBCH1756-TBS6H

1756-OB16D 16 diagnostic outputs(8 pointsgroup)

24V DC source 19230V DC 1756-TBCH1756-TBS6H

1756-OB16E 16 electronically fused outputs(8 pointsgroup)

1224V DC source 10312V DC 1756-TBNH1756-TBSH

1756-OB16I 16 individually isolated outputs

1224V DC sinksource 1030V DC 1756-TBCH1756-TBS6H

1756-OB16IS 16 individually isolated outputs8 scheduled outputs

1224V DC sinksource 1030V DC 1756-TBCH1756-TBS6H

1756-OB32 32 outputs(16 pointsgroup)

1224V DC source 10312V DC 1756-TBCH1756-TBS6H

Publication 1756-SG001P-EN-P - May 2011 9

Contact Output Modules

Analog Input Modules

1756-OC8 8 outputs(4 pointsgroup)

48V DC source 3060V DC 1756-TBNH1756-TBSH

1756-OG16 16 (8 pointsgroup) 5V DC TTL source (Low=True)

4555V DC 1756-TBNH1756-TBSH

1756-OH8I 8 outputsindividually isolated

120V DC 90146V DC 1756-TBCH1756-TBS6H

1756-OV16E 16 electronically fused outputs(8 pointsgroup)

1224V DC sink 1030V DC 1756-TBNH1756-TBSH

1756-OV32E 32 electronically fused outputs (16 pointsgroup)

1224V DC sink 1030V DC 1756-TBCH1756-TBS6H

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

Cat No InputsOutputs Operating Voltage Range Removable Terminal Block

1756-OW16I 16 normally open individually isolated outputs 5150V DC10265V AC

1756-TBCH1756-TBS6H

1756-OX8I 8 normally open8 normally closed individually isolated outputs(2 pointsgroup)

5150V DC10265V AC

1756-TBCH1756-TBS6H

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-IF6CIS 6 individually isolated inputs current sourcing

0hellip21 mA 16 bits034 Abit

1756-TBNH1756-TBSH

1756-IF6I 6 individually isolated inputs plusmn105V0hellip105V0hellip525V0hellip21 mA

16 bits105V 343 Vbit0hellip105V 171 Vbit0hellip525V 86 Vbit0hellip21 mA 034 Abit

1756-TBNH1756-TBSH

1756-IF8 8 single-ended inputs4 differential inputs2 high-speed differential inputs

plusmn1025V01025V05125V0hellip205 mA

plusmn1025V 320 Vcnt (15 bits plus sign bipolar)0hellip1025V 160 Vcnt (16 bits)0hellip5125V 80 V cnt (16 bits)0hellip205mA 032 Acnt (16 bits)

1756-TBCH1756-TBS6H

10 Publication 1756-SG001P-EN-P - May 2011

Analog RTD and Thermocouple Modules

Analog Output Modules

1756-IF8H 8 differential voltage or current inputs HART interface

plusmn10V05V1hellip5V010V0hellip20 mA4hellip20 mA

16hellip21 bits 1756-TBCH1756-TBS6H

1756-IF16 16 single-ended inputs8 differential or 4 differential (high speed) inputs

plusmn105V0hellip105V0hellip525V0hellip21 mA

16 bits105V 343 Vbit0hellip105V 171 Vbit0hellip525V 86 Vbit0hellip21 mA 034 Abit

1756-TBCH1756-TBS6H

1756-IF16H 16 differential current inputs HART interface

0hellip20 mA4hellip20 mA

16hellip21 bits 1756-TBCH1756-TBS6H

Cat No InputsOutputs Range Resolution Removable Terminal Block

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-IR6I 6 individually isolated RTD inputs 1hellip487 2hellip1000 4hellip20008hellip4020

16 bits1hellip487 77 mbit2hellip1000 15 mbit4hellip2000 30 mbit8hellip4020 60 mbit

1756-TBNH1756-TBSH

1756-IT6I 6 individually isolated thermocouple inputs1 CJC

-12hellip78 mV-12hellip30 mV

16 bits-1278 mV 14 Vbit-1230 mV 07 Vbit

1756-TBNH1756-TBSH

1756-IT6I2 6 individually isolated thermocouple inputs2 CJC

-12hellip78 mV (14 V per bit)-12hellip30 mV (07 V per bit ndash high resolution range)

16 bits-1278 mV 14 Vbit-1230 mV 07 Vbit

1756-TBNH1756-TBSH

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-OF4 4 voltage or current outputs plusmn104V0hellip21 mA

Voltage15 bits across 105V 320 VbitCurrent15 bits across 21mA 650 nAbit

1756-TBNH1756-TBSH

1756-OF6CI 6 individually isolated outputs current

0hellip21 mA 13 bits across 21 mA (27 A) 1756-TBNH1756-TBSH

1756-OF6VI 6 individually isolated outputs voltage

plusmn105V 14 bits across 21V (13 mV)(13 bits across 105V +sign bit)

1756-TBNH1756-TBSH

1756-OF8 8 voltage or current outputs plusmn104V0hellip21 mA

15 bits across 21 mA - 650 nAbit15 bits across 104V - 320 Vbit

1756-TBNH1756-TBSH

1756-OF8H 8 voltage or current outputs HART interface

plusmn104V0hellip20 mA4hellip20 mA

15hellip16 bits 1756-TBNH1756-TBSH

Publication 1756-SG001P-EN-P - May 2011 11

Analog Combination Input and Output Module

Specialty IO Modules

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-IF4FXOF2F 4 high-speed sub-millisecond differential inputs2 high-speed voltage or current outputs

Inputplusmn105V0hellip105V0hellip525V0hellip21 mAOutputplusmn104V0hellip21 mA

InputApprox 14 bits across plusmn10V DC (21V total)plusmn10V 13 mVbit 14-bit effective0hellip105V 13 mVbit 13-bit effective0hellip525V 13 mVbit 12-bit effectiveApprox 12 bits across 21 mA0hellip21 mA 525 AbitOutput13 bits across 21 mA = 28 Abit14 bits across 218V = 13 mVbit

1756-TBCH1756-TBS6H

Cat No InputsOutputs Description Removable Terminal Block

1756-CFM 4 inputs (2 per channel) 2 outputs current sourcing

Configurable flowmeter module2 Flowmeter (F) inputs used for all modes2 Gate inputs used in Totalizer mode for proverstore count

1756-TBNH1756-TBSH

1756-HSC 2 counters each with 3 inputs (A B Z for gatereset)4 outputs (2 pointsgroup)

High-speed counter module5V operation 45hellip55V DC1224V operation 10hellip312V DC

1756-TBCH1756-TBS6H

1756-PLS Left section 2 groups of 4 outputs and 4 inputs eachCenter section resolver interface and IO controlRight section 2 groups of 4 outputs and 4 inputs each

Programmable limit switch module Requires 3 RTBs 1756-TBNH or 1756-TBSH

12 Publication 1756-SG001P-EN-P - May 2011

HART Smart Instrumentation

HART (Highway Addressable Remote Transmitter) is an open protocol designed to connect analog devices For HART connectivity select from products available from Rockwell Automation and our Encompass partners

Typical HART Configuration

HART Interfaces

Accessories - IO Modules

1756 Removable Terminal Blocks

Removable terminal blocks (RTBs) provide a flexible interconnection between your plant wiring and 1756 IO modules The RTB plugs into the front of the IO module The type of module determines which RTB you need You can choose screw-clamp or spring-clamp RTBs

RTBs are not shipped with IO modules You must order them separately The standard housing on the front of the wiring arm is not deep enough for 25 mm2

HART Devices

ControlLogix Controller with 1756-IF8H or 1756-OF8H module

If your application has Select Description

Analog and HART connectivity in one moduleNo external hardware required to access HART signalHART commands can be transmitted as unscheduled messagesSupports asset management software to HART device

1756-IF8H1756-IF16H1756-OF8H

Rockwell Automation analog IO modules

Data acquisition or control application with slow update requirements (such as a tank farm)No external hardware required to access HART signalDoes not connect directly to asset management software

MVI56-HART Prosoft interface

Analog and HART in one moduleInstrumentation in hazardous locations (FLEX Ex modules)HART commands can be transmitted as unscheduled messagesDirectly connects asset management software to HART devices

1794 FLEX IO1797 FLEX Ex IO

There are specific FLEX IO and FLEX Ex modules designed for HART systems These catalog numbers end in an H such as 1797-IE8H

Publication 1756-SG001P-EN-P - May 2011 13

(14 AWG) wiring If you plan to use 25 mm2 (14 AWG) wiring also order the extended housing

Wiring Systems

As an alternative to buying RTBs and connecting the wires yourself you can buy a wiring system of the following

Interface modules (IFMs) that provide the output terminal blocks for digital IO modules Use the pre-wired cables that match the IO module to the IFM

Analog interface modules (AIFMs) that provide the output terminal blocks for analog IO modules Use the pre-wired cables that match the IO module to the AIFM

IO module-ready cables One end of the cable assembly is an RTB that plugs into the front of the IO module The other end has individually color-coded conductors that connect to a standard terminal block

Attribute 1756-TBNH 1756-TBSH 1756-TBCH 1756-TBS6H 1756-TBE

Description 20-position NEMA screw-clamp removable block

20-pin spring-clamp removable terminal block with standard housing

36-pin cage-clamp removable terminal block with standard housing

36-pin spring-clamp removable terminal block with standard housing

Extended depth terminal block housing

Screw torque 08hellip1 Nbullm7hellip9 lbbullin

04 Nbullm44 lbbullin

mdash

Screwdriver width 8 mm (516 in) max

IO Module

RTBPre-wired Cable

Factory-wired

Interface Module (IFM)

Field Wiring

14 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Integrated Motion

The Logix architecture supports motion control components that work in a wide variety of machine architectures

Integrated motion on EtherNetIP supports a connection to Ethernet drives

The Kinetix integrated-motion solution uses a SERCOS interface module to perform multi-axis synchronized motion

Logix integrated motion supports the analog family of servo modules for controlling drivesactuators

Networked motion provides the ability to connect via the DeviceNet network to a single axis drive to perform point-to-point indexing

For detailed specifications on motion interface modules see 1756 ControlLogix Integrated Motion Specifications publication 1756-TD004

For more information see these publications

Motion Analyzer CD to size your motion application and to make final component selection Download the software from httpwwwabcommotionsoftwareanalyzerhtml

Kinetix Motion Control Selection Guide publication GMC-SG001 to verify drive motor and accessory specifications

Integrated Motion on an EtherNetIP Network

Product Consideration

Drive that supports EtherNetIP connections Unlimited velocity torque and Vhz configured drives Kinetix 6500 drives PowerFlex 755 drives

ControlLogix controller As many as 100 drives per controller

ControlLogix EtherNetIP communication module 1hellip8 position configured drives with 1756-EN2TR module 1hellip255 position configured drives with 1756-EN3TR module

Publication 1756-SG001P-EN-P - May 2011 15

SERCOS Interface Modules

The SERCOS interface modules can connect to these servo drives

2093 Kinetix 2000 multi-axis servo drive 2094 Kinetix 6000 multi-axis servo drive 2099 Kinetix 7000 high-power servo drive 2098 Ultra3000 SERCOS servo drive

ControlLogix Controller

PanelView Plus Terminal

Workstations

POINT IO ModulesDrive with EtherNetIP Connection

Cat No Description Number of Axis

1756-M16SE Rockwell Automation SERCOS interface modules 16

1756-M08SE 8

1756-M03SE 3

1756-M08SEG SERCOS interface drives that are Extended Pack Profile compliant 8

16 Publication 1756-SG001P-EN-P - May 2011

Analog Motion Interface Modules

RSLogix 5000 Software1756-MxxSE Module

ControlLogix Controller

Three-phase Input Power

Line Interface Module

Integrated Axis Module

Motor Motor Feedback

Axis Modules

Slot Filler Module

Shunt Module

SERCOS Fiber-optic RingKinetix 6000 Multi-axis Servo Drive

Cat No Description Number of Axis

1756-M02AE Analog servo interface drives with quadrature feedback 2

1756-HYD02 Analog hydraulic servo interface drives LDT feedback 2

1756-M02AS Analog servo interface drives with SSI feedback 2

Publication 1756-SG001P-EN-P - May 2011 17

ControlLogix Communication Modules

Separate communication modules are available for different networks Install multiple communication modules into the ControlLogix backplane to bridge or route control and information data between different networks You can route a message through a maximum of four chassis (eight communication hops) You do not need a ControlLogix controller in the chassis

For detailed specifications see 1756 ControlLogix Network Specifications publication 1756-TD003

Application Network Page

Plant management (material handling) Configuration data collection and control on a single high-speed network Time-critical applications with no established schedule Inclusion of commercial technologies (such as video over IP) InternetIntranet connection Integrated CIP motion and safety

EtherNetIP network 19

High-speed transfer of time-critical data between controllers and IO devices Deterministic and repeatable data delivery Media redundancy Intrinsic safety Redundant controller systems

ControlNet network 20

Connections of low-level devices directly to plant floor controllers without interfacing them through IO modules

Data sent as needed More diagnostics for improved data collection and fault detection Less wiring and reduced start-up time than a traditional hard-wired system

DeviceNet network 21

Plant-wide and cell-level data sharing with program maintenance Data sent regularly Transfer of information between controllers

Data Highway Plus network 23

Connections between controllers and IO adapters Data sent regularly Distributed control so that each controller has its own IO and communicates with a

supervisory controller

Remote IO network 23

Fieldbus transmitters and actuators Closed-loop control Process automation

Foundation Fieldbus network 25

18 Publication 1756-SG001P-EN-P - May 2011

EtherNetIP Communication Modules

The Ethernet Industrial (EtherNetIP) network protocol is an open industrial-networking standard that supports both real-time IO messaging and message exchange The EtherNetIP network uses off-the-shelf Ethernet communication chips and physical media

Accessories - EtherNetIP Network

Cat No Description Media Communication Rate

CIP Motion Axes max

TCPIP Connections

Logix Connections

1756-EN2F EtherNetIP bridge fiber Fiber 100 Mbps 8 128 256

1756-EN2T EtherNetIP bridge copper Copper 10100 Mbps 8 128 256

1756-EN2TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 8 128 256

1756-EN3TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 255 128 256

1756-ENBT EtherNetIP bridge copper Copper 10100 Mbps mdash 64 128

1756-EWEB Ethernet web server module Copper 10100 Mbps mdash 64 128

1756-EN2TXT ControlLogix-XT extended temperature EtherNetIP bridge copper for extreme environments

Copper 10100 Mbps 8 128 256

Cat No Description Specifications

1585J-M8PBJM-x Ethernet RJ45 patchcordx = 2 (2 m) 5 (5 m) or 10 (10 m)

8-conductor Teal Riser PVC Cable (Flex Rated cable also available)

1585J-M8CC-H RJ45 insulation displacement connector (IDC) 01280325 mm2 (26hellip22 AWG) Cat 6 IDC no tool required

1585J-M8CC-C RJ45 crimp connector with boot qty = 50 pieces 01280205 mm2 (26hellip24 AWG Cat 5e requires crimp tool for assembly

1585A-Jcrimp Crimp tool mdash

9300-RADES Remote access dial-in kit 56 Kbps modem connection to devices on an Ethernet network includes pre-configured modem communication module DIN rail mounting hardware associated cables

Publication 1756-SG001P-EN-P - May 2011 19

Example Configuration - EtherNetIP Network

ControlNet Communication ModulesThe ControlNet network combines the functionality of an IO network and a peer-to-peer network providing high-speed performance The ControlNet network provides deterministic repeatable transfers of critical control data

FirewallRouter

Stratix Switch

Stratix Switch

Stratix Switch

Powermonitor 3000PowerFlex 70

Ethernet PLC-5

MicroLogix

Ethernet SLC 500

1756 IO

1794 IO

1761-NET-ENI

ControlNet

DeviceNet

1734 IO

RSLinxPanelView Plus

1769-L35E CompactLogix

Cat No Description Communication Rate

Logix Connections Number of Nodes

1756-CN2B ControlNet bridge standard media 5 Mbps 128(1) 99

1756-CN2RB ControlNet bridge redundant media 5 Mbps 128(1) 99

1756-CNB ControlNet bridge standard media 5 Mbps 64(2) 99

1756-CNBR ControlNet bridge redundant media 5 Mbps 64(2) 99

1756-CN2RXT ControlLogix-XT extended temperature ControlNet bridge redundant media

5 Mbps 128(1) 99

(1) 128 connections are available for standard use An additional three connections are reserved for redundant control

(2) Recommend using only 4048 Logix connections for IO

20 Publication 1756-SG001P-EN-P - May 2011

Example Configuration - ControlNet Network

Example Configuration - Redundant ControlNet Media

For information on ControlNet media see ControlNet Media System Components List AG-PA002

DeviceNet Communication Module

The DeviceNet network provides connections between simple industrial devices (such as sensors and actuators) and higher-level devices (such as controllers and computers)

1784-U2CNPanelView Plus

1788-CN2DN

DeviceNetPowerFlex 700SPLC-540CControlLogix

Redundant Media

ControlLogix1756-CNBR

ControlNet Node

ControlNet Node

Cat No Description Communication Rate Number of Nodes

1756-DNB DeviceNet bridge 125 Kbps (500 m max)250 Kbps (250 m max)500 Kbps (100 m max)

64

Publication 1756-SG001P-EN-P - May 2011 21

Example Configuration - DeviceNet Network

Accessories - DeviceNet Network

PLC-51771-SDN ControlLogix

1756-DNB

Ultra3000

PanelView Plus1784-U2DN

Ultra5000

IO

Motor starter

PowerFlex AC

Sensor Pushbuttons

LightsBar Code Scanner

Cat No Description

KwikLink Lite flat media KwikLink Lite flat media is a newer ODVA-approved solution for wiring DeviceNet networks Drop-lines for connecting nodes are added by using the KwikLink Lite two-piece connectors This cable system supports the intermixing of DeviceNet cable types (thin-round with flat) All of the KwikLink Lite connectors provide insulation displacement technology with reduced assembly time

KwikLink flat media The KwikLink flat media system provides a modular cabling method with its flat 4-wire cable and insulation displacement connectors (IDCs) The KwikLink system allows nodes to be added to the network without severing the trunkline Cutting or stripping of the trunkline is eliminated as is the need for predetermined cable lengths

Round media Round trunk cable is available in bulk spools or as pre-molded cordsets or patchcords in varying lengths A wide variety of rugged durable DeviceNet components is available for use in round trunk systems Stainless steel versions of round cable system components are also available Thick-trunk round media systems use thick cable for maximum DeviceNet trunk line length Round media thin-trunk systems use thin cable to reduce maximum trunk line distances with a more

compact and cost-effective installation for some applications Thin-cable outer jacket material is TPE for additional chemical resistance

22 Publication 1756-SG001P-EN-P - May 2011

Data Highway Plus and Remote IO Communication Modules

The Data Highway Plus network supports messaging between devices The remote IO link connects to remote IO chassis and other intelligent devices

The 1756-DHRIO module supports messaging between devices on DH+ networks The remote IO functionality enables the module to act as a scanner for transferring digital and block-transfer data to and from remote IO devices

The 1756-RIO module can act as a scanner or adapter on a remote IO network In addition to digital and block-transfer data the 1756-RIO module transfers analog and specialty data without message instructions

Cat No Description Communication Rate DH+ Connections RIO Connections Maximum Recommended Logix Connections

1756-DHRIO Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

1756-RIO Remote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

mdash Remote IO scanner or adapter32 physical racks (076) any combination of rack size and block transfers

10 scheduled IO

1756-DHRIOXT ControlLogix-XT extended temperature Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

Publication 1756-SG001P-EN-P - May 2011 23

Example Configuration - DH+ Network

Example Configuration - Remote IO Network

Accessories - DH+ and Remote IO Networks

PanelView Plus

PLC-5 1784-U2DHPRSLogix 5000

ControlLogix1756-DHRIO

SLC 504

PanelView PlusPLC-5

1791 IO1794 IO

1756-RIO as a Remote IO Adapter

1756-DHRIO as a Remote IO Scanner

Cat No Description Specifications

1770-CD Cable to connect communication module to DH+ network Belden 9463 twinaxial

9300-RADKIT Remote access dial-in kit 56 Kbps modem connection to devices on a DH+ network includes pre-configured modem communication module DIN rail mounting hardware associated cables

24 Publication 1756-SG001P-EN-P - May 2011

FOUNDATION Fieldbus Linking Devices

The FOUNDATION Fieldbus protocol is a network designed for distributed control of process applications

Example Configuration - Bridge to EtherNetIP Network

Cat No Description Communication Rate Number of H1 Ports

Devices per H1 Link

Devices per Linking Device

1757FFLD2 FOUNDATION Fieldbus bridge to an Ethernet network

FOUNDATION Fieldbus 3125 KbpsEtherNetIP 10100 Mbps

2 16(8hellip10 recommended)

32

1757-FFLD4 4 64

1757-FFLDC2 FOUNDATION Fieldbus bridge to a ControlNet network

FOUNDATION Fieldbus 3125 KbpsControlNet 5 Mbps

2 16(8hellip10 recommended)

32

1757-FFLDC4 4 64

FactoryTalk View SERSFieldbusRSLogix 5000

1757-FFLD4

H1(1)

H1(2)H1(3)H1(4)

HSEIP

Publication 1756-SG001P-EN-P - May 2011 25

Example Configuration - Bridge to ControlNet Network

Other Connectivity Options

ControlLogix RedundancyFactoryTalk View SERSFieldbusRSLogix 5000

ControlNet Redundant Media

1757-FFLDC2

FF H1

EtherNetIP

Option Consideration

USB connection The 1756-L7x controller has a USB port in place of the serial port If your application requires RS-232 functionality see the many Encompass partners at httpwwwrockwellautomationcomencompass

Serial connection The serial port on the 1756-L6x controller is compatible with RS-232 serial communication The serial port supports the DF1 protocol to communicate with other devices on the serial linkTo use Logix5000 controllers on Modbus you connect through the serial port and execute a specific ladder logic routine The controller project is available with RSLogix 5000 Enterprise programming software For more information see Using Logix5000 Controllers as Masters or Slaves on Modbus Application Solution publication CIG-AP129

DH-485 network The controller serial port is compatible with DH-485 communication The DH-485 connection does support remote programming and monitoring via RSLogix 5000 softwareOr add a DH-485 communication bridge module (cat no 1756-DH485)

SynchLink network The SynchLink communication module (1756-SYNCH) provides time synchronization and data broadcasting capabilities for distributed motion and coordinated drive control The module connects a ControlLogix chassis to a SynchLink fiber-optic communication link

26 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Controllers The ControlLogix controller provides a scalable controller solution that is capable of addressing a large amount of IO points

The controller can be placed into any slot of a ControlLogix chassis and multiple controllers can be installed in the same chassis Multiple controllers in the same chassis communicate with each other over the backplane (just as controllers can communicate over networks) but operate independently

ControlLogix controllers can monitor and control IO across the ControlLogix backplane as well as over IO links ControlLogix controllers can communicate over EtherNetIP ControlNet DeviceNet DH+ Remote IO and RS-232-C (DF1DH-485 protocol) networks and many third party process and device networks To provide communication for a ControlLogix controller install the appropriate communication interface module into the chassis

For detailed specifications see 1756 ControlLogix Controllers Specifications publication 1756-TD001

Cat No Description User Memory

1756-L72 ControlLogix controller 1 built-in USB port 4 MB

1756-L73 8 MB

1756-L74 16 MB

1756-L75 32 MB

1756-L61 ControlLogix controller 1 built-in RS-232 port 2 MB

1756-L62 4 MB

1756-L63 8 MB

1756-L64 16 MB

1756-L65 32 MB

1756-L61S GuardLogix safety controller 2 MB standard1 MB safety

1756-L62S 4 MB standard1 MB safety

1756-L63S 8 MB standard375 MB safety

1756-LSP GuardLogix safety partner (one is required for each GuardLogix controller) mdash

1756-L63XT ControlLogix-XT controller extreme environment 8 MB

IMPORTANT Scan time for a project loaded in a 1756-L64 or 1756-L65 controller may be slower than for the same project loaded in one of the other 1756-L6x controllers See the Logix5000 Controllers Instruction Execution Time and Memory Use Reference Manual publication 1756-RM087 for instruction execution times

Publication 1756-SG001P-EN-P - May 2011 27

Standard ControlLogix Controllers

The ControlLogix controller is part of the Logix5000 family of controllers A ControlLogix system includes the following

The ControlLogix controller available in different combinations of user memory

RSLogix 5000 programming software 1756 ControlLogix IO modules that reside in a 1756 chassis Separate communication modules for network communication

Features - Standard ControlLogix Controllers

Feature 1756-L61 1756-L62 1756-L63 1756-L64 1756-L65

1756-L72 1756-L73 1756-L74 1756-L75

Controller tasks 32 tasks 100 programstask Event tasks all event triggers

Built-in communication ports 1 port RS-232 serial 1 port USB

Communication options EtherNetIP ControlNet DeviceNet Data Highway Plus Remote IO SynchLink Third-party process and device networks

Built-in port Serial USB

Controller connections supported max 250 500

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Full support

Integrated motion EtherNetIP connection SERCOS interface Analog options (encoder input LDT input SSI input)

Programming languages Relay ladder Structured text Function block SFC

28 Publication 1756-SG001P-EN-P - May 2011

GuardLogix Controllers

A GuardLogix controller is a ControlLogix controller that also provides safety control The GuardLogix system is a dual controller solutionmdashyou must use a 1756-L6xS primary controller and a 1756-LSP safety partner to achieve SIL 3CAT 4

During development safety and standard have the same rules multiple programmers online editing and forcing are all allowed Once the project is tested and ready for final validation you set the Safety Task to a SIL 3 integrity level which is then enforced by the GuardLogix controller When safety memory is locked and protected the safety logic cant be modified and all safety functions operate with SIL 3 integrity On the standard side of the GuardLogix controller all functions operate like a regular Logix controller

Use Guard IO modules for field device connectivity on Ethernet or DeviceNet networks and for safety interlocking between GuardLogix controllers use Ethernet or ControlNet networks Multiple GuardLogix controllers can share safety data for zone to zone interlocking or a single GuardLogix controller can use remote distributed safety IO between different cellsareas

In addition to the standard features of a ControlLogix controller the GuardLogix controller has these safety-related features

Application Description

SIL 1 2 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508 and applications up to and including PLeCat4 according to ISO 13849-1 For more information see GuardLogix Controllers Systems Safety Reference Manual publication 1756-RM093 GuardLogix Controllers User Manual publication 1756-UM020 GuardLogix Safety Application Instruction Set Reference Manual publication 1756-RM095

Features - GuardLogix Controllers

Feature 1756-L61S 1756-L62S 1756-L63S 1756-LSP

Safety communication options Standard and safety EtherNetIP ControlNet DeviceNet

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Not supported

Programming languages Relay ladder

Publication 1756-SG001P-EN-P - May 2011 29

ControlLogix-XT Controllers

The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh corrosive environments

When used with FLEX IO-XT products the ControlLogix-XT system can withstand temperatures range from -2070 C (-4158 F)

When used independently the ControlLogix-XT system can withstand temperature ranges from -2570 C (-13158 F)

Redundant ControlLogix Controllers

The ControlLogix controller supports controller redundancy In a redundant controller system you need these components

Two 1756 chassis each with the following the same ndash Number of slots

ndash Modules in the same slots

ndash Redundancy firmware revisions in each module

ndash Two additional ControlNet nodes outside the redundant chassis pair

You need one of these redundancy modules

One 1756-RM module per chassis that supports the followingndash Two 1756-L61 1756-L62 1761-L63 controllers or one 1756-L64

controller

ndash Maximum of seven communication modules which can be 1756-CN2 series B 1756-CN2R series B and 1756-EN2T modules

ndash One 1756-RMCx cable

One 1757-SRM module per chassis that supports the followingndash One 1756-L61 1756-L62 1756-L63 1756-L64 controller

ndash Maximum of seven communication modules which can be 1756-CNB series D or E 1756-CNBR series D or E 1756-ENBT and 1756-EWEB modules

ndash One 1757-SRCx cable

30 Publication 1756-SG001P-EN-P - May 2011

Accessories - Controllers

Memory Cards

Memory cards offer nonvolatile memory to permanently store a user program and tag data on a controller The 1756-L7x ControlLogix controller comes with 1784-SD1 Secure Digital (SD) card already installed The 1756-L6x controllers support optional CompactFlash cards that you purchase separately The memory card installs in a socket on the controller Through RSLogix 5000 software you can manually trigger the controller to save to or load from nonvolatile memory or configure the controller to load from nonvolatile memory on powerup

The GuardLogix controller does not support user program storage or retrieval by using a CompactFlash card

1756 Energy Storage Modules

Instead of a battery the 1756-L7x controller ships with a 1756-ESMCAP energy storage module (ESM) already installed

Attribute 1784-CF64 1784-CF128 1784-SD1 1784-SD2

Memory 64 MB 128 MB 1 GB 2 GB

Supported controllers 1756-L6x 1756-L7x

Weight approx 142 g (05 oz) 176 g (0062 oz)

Cat No Description

1756-ESMCAP Capacitor-based energy-storage module Comes with the controller

1756-EMNSE ESM without WallClockTime backup power Additionally you can use this ESM with a 1756-L73 (8 MB) or smaller memory-sized controller only

Use this ESM if your application requires that the installed ESM deplete its residual energy to 40 microJoule or less before transporting it into or out of your application

1756-ESMNRM Energy-storage module that secures the controller by preventing the USB connection and SD card useThis ESM provides your application an enhanced degree of security

Publication 1756-SG001P-EN-P - May 2011 31

1756 ControlLogix Batteries

Each 1756-L6x controller ships with a battery With a memory card installed the controller can be used without a battery If you do not use a battery current tag data will be at the state it was when the memory card was saved

ControlLogix Chassis The ControlLogix system is a modular system that requires a 1756 IO chassis Place any module into any slot The backplane provides a high-speed communication path between modules

All of the chassis are designed for horizontal-only back-panel mounting The chassis are available in these configurations

Standard chassis ControlLogix-XT chassis

For detailed specifications see 1756 ControlLogix Chassis Specifications Specifications publication 1756-TD006

Features - Chassis

Slot guides and snap-in retention for easy and secure module fit for any type of 1756 module

Direct mounting accommodates any 1756 power supply

Attribute 1756-BA1 1756-BA2 1756-BATM(1) 1756-BATA

Description Lithium battery (059 g) Lithium battery (059 g) Externally mounted battery assembly

Replacement lithium battery for 1756-BATM (5 g max lithium per each D cell contains 2 D cells)

ControlLogix controllers 1756-L61 1756-L62 1756-L63 series A

1756-L61 1756-L62 1756-L63 series B1756-L64 1756-L65

1756-L61 1756-L62 1756-L63 series A

1756-BATM battery module

GuardLogix controllers mdash 1756-L61S 1756-L62S 1756-L63S

mdash mdash

ControlLogix-XT controllers

mdash 1756-L63XT mdash mdash

(1) The 1756-BATM externally mounted battery assembly is highly recommended for use with all series A 1756-L6x controllers and provides longer battery life than the 1756-BA1 battery The 1756-BATM includes one 1756-BATA lithium battery assembly and a 1 m (328 ft) cable to connect housing to controller

32 Publication 1756-SG001P-EN-P - May 2011

Standard Chassis

The chassis backplane provides a high-speed communication path between modules and distributes power to each of the modules within the chassis

ControlLogix-XT Chassis

The ControlLogix-XT chassis support extreme temperature environments

Accessories - Chassis

Use a slot filler module to fill empty slots

Cat No Description Slots

1756-A4 ControlLogix standard chassis 4

1756-A7 7

1756-A10 10

1756-A13 13

1756-A17 17

Cat No Description Slots Temperature Range

1756-A4LXT ControlLogix-XT chassis 4 -2560 degC (-13140 degF)

1756-A5XT 5 -2570 degC (-13158 degF)

1756-A7LXT 7 -2560 degC (-13140 degF)

Cat No Description

1756-N2 Slot filler module for empty slots in standard ControlLogix chassis

1756-N2XT Slot filler module for empty slots in ControlLogix-XT chassis

Publication 1756-SG001P-EN-P - May 2011 33

ControlLogix Power Supplies

ControlLogix power supplies are used with the 1756 chassis to provide 12V 33V 5V and 24V DC power directly to the chassis backplane Select from these configurations

Standard power Redundant power ControlLogix-XT power

For detailed specifications see 1756 ControlLogix Power Supplies Specifications publication 1756-TD005

Standard Power Supplies

You mount a standard power supply directly on the left end of the chassis where it plugs directly into the backplane

ControlLogix-XT Power Supplies

The ControlLogix-XT power supplies support extreme temperature environments

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA72 ControlLogix standard AC 120V220V AC 85hellip265V AC Standard series A and series B

1756-PA75 120V220V AC 85hellip265V AC Standard series B

1756-PB72 ControlLogix standard DC 24V DC 18hellip32V DC Standard series A and series B

1756-PB75 24V DC 1832V DC Standard series B

1756-PC75 48V DC 30hellip60V DC Standard series B

1756-PH75 125V DC 90hellip143V DC Standard series B

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PAXT ControlLogix-XT AC power supply 85265V AC 120240V AC XT

1756-PBXT ControlLogix-XT DC power supply 24V DC 18hellip32V DC XT

34 Publication 1756-SG001P-EN-P - May 2011

Redundant Power Supplies

To build a redundant power supply system you need the following

Two redundant power supplies (both 1756-PA75R or 1756-PB75R) One 1756-PSCA2 chassis adapter module Two 1756-CPR2 cables to connect the power supplies to the

1756-PSCA2 chassis adapter module (091 m (3 ft) length) User-supplied annunciator wiring to connect the power supplies to the

input modules as needed

The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Accessories - Redundant Power Supplies

Visualization Products Visualization products together with Logix for control and NetLinx architecture for communication make up the Rockwell Automation Integrated Architecture strategy The visualization strategy combines Rockwell Automation expertise in Allen-Bradley electronic operator interface and industrialized personal computer hardware with Rockwell Software supervisory control software Current visualization products include the following

FactoryTalk View software PanelView Plus operator interface PanelView Plus CE operator interface Industrial computers and monitors

For more information see the Operator Interface catalog pages at httpwwwabcomenepubcatalogs1276221813761239781

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA75R ControlLogix redundant 120V220V AC 85hellip265V AC Standard series B

1756-PB75R 24V DC 192hellip32V DC Standard series B

Cat No Description Specifications

1756-PSCA2 Chassis adapter module Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Mounts directly to left side of 1756 chassis

1756-CPR2 Chassis adapter cable Connects redundant power supply to 1756-PCSA2 chassis adapter Length091 m (3 ft)

Publication 1756-SG001P-EN-P - May 2011 35

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

Select a ControlLogix System

Step 1ControlLogix IO Modules

Step 2ControlLogix Integrated Motion

Step 3ControlLogix Communication Modules

1756 ControlLogix System

Step 4ControlLogix Controllers

Step 5ControlLogix Chassis

Step 6ControlLogix Power Supplies

Select IO modules - some modules have field-side

diagnostics electronic fusing or individually isolated inputsoutputs

A remote terminal block (RTB) or wiring system for each IO module

Select A SERCOS or analog interface module

Associated cables

A removable terminal block (RTB) - only for analog interface modules

Select drives motors and accessories (use the Motion Analyzer software)

Select Networks

Communication modules

Associated cables and network equipment

Sufficient modules and cables if you are planning a redundant system

Select A controller with sufficient memory

Secure Digital or CompactFlash card

Replacement batteries if needed

Select A chassis with sufficient slots

Slot fillers for empty slots

Select One power supply for each chassis if you are using

standard power supplies

A power supply bundle if you are planning a redundant power supply system

Optional StepProgramming Software

Optional StepVisualization Products

Page 8

Page 15

Page 18

Page 27

Page 32

Page 34

Page 35 Page 36

3Publication 1756-SG001P-EN-P - May 2011 3

ControlLogix System Overview

The ControlLogix system provides discrete drives motion process and safety control together with communication and state-of-the-art IO in a small cost-competitive package The system is modular so you can design build and modify it efficiently with significant savings in training and engineering

Example Configuration - ControlLogix System

A simple ControlLogix system consists of a standalone controller and IO modules in a single chassis For a more comprehensive system use the following

Multiple controllers in a single chassis Multiple controllers joined across networks IO in multiple platforms that are distributed in many locations and

connected over multiple IO links

RUN IO

RS232

OK

FORCE

BAT

RUN REM PROG

Logix5564

OKCP

SERCOS

OKAB

OKIOMODNET OKIOMODNET

ST

ST

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

HART

ANALOG INPUT

OK

DIAGNOSTIC

FLT

ST

FLT

ST

0 1 2 3 4 5 6 7

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

8 9 10 11 12 13 14 15

DC OUTPUT

DIAGNOSTIC

FLT

ST

FLT

ST

0 1 2 3 4 5 6 7

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

8 9 10 11 12 13 14 15

DC INTPUT

POWER

STATUS

WDOG

BATT

NS

MODE

H1-1H1-2H1-3H1-4

DANGERDANGERDANGERDANGER

755

98

2

5

0

3

6

7

1

4

Logix55LSP

SAFETY

RUN

SAFETY

TASK

BAT OK

RUN IO

RS232

OK

FORCE

BAT

RUN REM PROG

Logix5561

Plant MRP SystemDatabaseTracking Systems

Laptop

Stratix 8000

POINT Guard IO

FLEX IO

PanelView Plus

PowerFlex 755

CompactBlock Guard IO

PowerFlex 70

Other Devices

EtherNetIP

Kinetix Servo Drive

Motor Feedback

Servo Motor

Motor Power

DeviceNet

FLEX IO-XT

Tower LightArmorBlock Guard IO

PowerFlex 70

Valve

Guard IO

HART

ControlNet

Flowmeter

LevelFoundation Fieldbus

1756

-L61

S17

56-L

SP17

56-L

64SE

RCOS

1756

-EN

2T17

56-C

N2

1756

-DN

BIO IO An

alog

4 Publication 1756-SG001P-EN-P - May 2011

ControlLogix-XT System

The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh corrosive environments

When used with FLEX IO-XT products the ControlLogix-XT system can withstand temperatures range from -2070 C (-4158 F)

When used independently the ControlLogix-XT system can withstand temperature ranges from -2570 C (-13158 F)

GuardLogix Safety System

A GuardLogix controller is a ControlLogix controller that also provides safety control The GuardLogix system is a dual controller solution mdash you must use a 1756-L6xS primary controller and a 1756-LSP safety partner to achieve SIL 3CAT 4 A major benefit of this system is that itrsquos still a single project safety and standard together The safety partner controller is a part of the system is automatically configured and requires no user setup

Application Description

SIL 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508 and applications up to and including category (CAT) 4 according to EN954-1 For more information see the following GuardLogix Controllers Systems Safety Reference Manual publication 1756-RM093 GuardLogix Controllers User Manual publication 1756-UM020 GuardLogix Safety Application Instruction Set Reference Manual publication 1756-RM095

SIL 2 Components of the ControlLogix system are type-approved and certified for use in SIL 2 applications according to IEC 61508 and AK4 applications according to DIN V19250 For a list of ControlLogix system components that meet SIL 2 requirements see Using ControlLogix in SIL 2 Applications Safety Reference Manual publication 1756-RM001

Publication 1756-SG001P-EN-P - May 2011 5

Example Configuration - Redundant ControlLogix System

The ControlLogix controller supports controller redundancy

OKAB

AB

DIAGNOSTIC

FLT

ST

FLT

ST

0 1 2 3 4 5 6 7

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

8 9 10 11 12 13 14 15

DC INTPUT

DIAGNOSTIC

FLT

ST

FLT

ST

0 1 2 3 4 5 6 7

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

8 9 10 11 12 13 14 15

DC OUTPUT

ST

ST

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

HART

ANALOG INPUT

OK

DIAGNOSTIC

FLT

ST

FLT

ST

0 1 2 3 4 5 6 7

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

8 9 10 11 12 13 14 15

DC INTPUT

DIAGNOSTIC

FLT

ST

FLT

ST

0 1 2 3 4 5 6 7

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

8 9 10 11 12 13 14 15

DC OUTPUT

ST

ST

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

HART

ANALOG INPUT

OK

POWER

OKAB

AB

OKCOMMPRI

REDUNDANCY MODULE

RUN IO

RS232

OK

FORCE

BAT

RUN REM PROG

Logix5564

RUN IO

RS232

OK

FORCE

BAT

RUN REM PROG

Logix5562

OKNETLINK

POWERPOWER

POWER

OKAB

AB

OKCOMMPRI

REDUNDANCY MODULE

RUN IO

RS232

OK

FORCE

BAT

RUN REM PROG

Logix5564

RUN IO

RS232

OK

FORCE

BAT

RUN REM PROG

Logix5562

OKNETLINK

ESC SEL

EOI or HMI

EtherNetIP or ControlNet

1756-RM

1756-EN2T

1756-CN2RB1756-RM

1756-L61 1756-L62 or 1756-L63

1756-EN2T

1756-CN2RB

Primary ControlLogix Chassis Secondary ControlLogix Chassis

Fiber Optic Cable

FLEX IO

1203-CN1

1336 Plus II AC Drive

1756-CNBR

1756-PA75R or 1756-PB75R Redundant Power Supplies Redundant ControlNet

ControlLogix IO1756-PSCA2 Chassis Adapter

1756-CPR2 Cables

1756-L61 1756-L62 or 1756-L63

6 Publication 1756-SG001P-EN-P - May 2011

Example Configuration - Redundant IO System

The 1715 redundant IO system lets a ControlLogix controller communicate to a remote redundant IO chassis over an EtherNetIP network The 1715 redundant IO system provides fault tolerance and redundancy for critical processes by using a redundant adapter pair and multiple IO modules that have diagnostics

The redundant IO system must be connected to a ControlLogix system via an EtherNetIP network All connections are established via the Ethernet network by using the topologies supported by the 1756-EN2TR communication bridge

For detailed specifications see the 1715 Redundant IO System Specifications Technical Data publication 1715-TD001A-EN-P

1756

-RM

1756

-EN

2TR

IO B

ASE

1715

-A31

0

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

IO B

ASE

1715

-A31

0

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

1715

-AEN

TR

1756

-EN

2TR

1756

-RM

1715

-AEN

TR

1715

-IO

1715

-IO

1715

-IO

1715

-IO

1715

-IO

1715

-IO

ControlLogix Primary Chassis ControlLogix Secondary Chassis

1715 Redundant IO System

Publication 1756-SG001P-EN-P - May 2011 7

ControlLogix IO Modules The ControlLogix architecture provides a wide range of input and output modules to span many applications from high-speed digital to process control The ControlLogix architecture uses a producerconsumer model so that input information and output status can be shared among multiple controllers

Each ControlLogix IO module mounts in a ControlLogix chassis and requires either a removable terminal block (RTB) or a 1492 interface module (IFM) to connect all field-side wiring RTBs and IFMs are not included with the IO modules They must be ordered separately

For detailed specifications see 1756 ControlLogix IO Modules Specifications publication 1756-TD002

AC Digital put Modules

AC Digital Output Modules

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

1756-IA8D 8 diagnostic inputs(4 pointsgroup)

120V AC 79hellip132V AC 1756-TBNH1756-TBSH

1756-IA16 16 inputs(8 pointsgroup)

120V AC 74hellip132V AC 1756-TBNH1756-TBSH

1756-IA16I 16 individually isolated inputs 120V AC 74hellip132V AC 1756-TBCH1756-TBS6H

1756-IA32 32 diagnostic inputs(4 pointsgroup)

120V AC 74hellip132V AC 1756-TBCH1756-TBS6H

1756-IM16I 16 individually isolated inputs 240V AC 159hellip265V AC 1756-TBCH1756-TBS6H

1756-IN16 16 inputs(8 pointsgroup)

24V AC 10hellip30V AC 1756-TBNH1756-TBSH

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

1756-OA8 8 outputs(4 pointsgroup)

120240V AC 79hellip265V AC 1756-TBNH1756-TBSH

1756-OA8D 8 diagnostic electronically fused outputs(4 pointsgroup)

120V AC 74hellip132V AC 1756-TBNH1756-TBSH

1756-OA8E 8 electronically fused outputs(4 pointsgroup)

120V AC 74hellip132V AC 1756-TBNH1756-TBSH

1756-OA16 16 mechanically fusedgroup outputs(8 pointsgroup)

120240V AC 74hellip265V AC 1756-TBNH1756-TBSH

1756-OA16I 16 individually isolated outputs

120240V AC 74hellip265V AC 1756-TBCH1756-TBS6H

1756-ON8 8 outputs(4 pointsgroup)

24V AC 10hellip30V AC current gt50 mA16hellip30V AC current lt50 mA

1756-TBNH1756-TBSH

8 Publication 1756-SG001P-EN-P - May 2011

DC Digital Input Modules

DC Digital Output Modules

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

1756-IB16 16 inputs(8 pointsgroup)

1224V DC sink 10312V DC 1756-TBNH1756-TBSH

1756-IB16D 16 diagnostic inputs(4 pointsgroup)

1224V DC sink 1030V DC 1756-TBCH1756-TBS6H

1756-IB16I 16 individually isolated inputs 1224V DC sinksource 1030V DC 1756-TBCH1756-TBS6H

1756-IB16ISOE 16 individually isolated sequence of events inputs

2448V DC sinksource 1055V DC 1756-TBCH1756-TBS6H

1756-IB32 32 inputs(16 pointsgroup)

1224V DC sink 10312V DC 1756-TBCH1756-TBS6H

1756-IC16 16 inputs(8 pointsgroup)

48V DC sink 3055V DC 60 degC (140 degC)3060V DC 55 degC (131 degC)

1756-TBNH1756-TBSH

1756-IG16 16 inputs(8 pointsgroup)

5V DC TTL source (Low=True)

4555V DC 1756-TBNH1756-TBSH

1756-IH16I 16 individually isolated inputs 125V DC sinksource 90146V DC 1756-TBCH1756-TBS6H

1756-IH16ISOE 16 individually isolated sequence of events inputs

125V DC sinksource 90140V DC 1756-TBCH1756-TBS6H

1756-IV16 16 inputs(8 pointsgroup)

1224V DC source 1030V DC 1756-TBNH1756-TBSH

1756-IV32 32 inputs(16 pointsgroup)

1224V DC source 1030V DC 1756-TBCH1756-TBS6H

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

1756-OB8 8 outputs 1224V DC source 1030V DC 1756-TBNH1756-TBSH

1756-OB8EI 8 electronically fused individually isolated outputs

1224V DC source 1030V DC 1756-TBCH1756-TBS6H

1756-OB8I 8 individually isolated outputs 1224V DC source 1030V DC 1756-TBCH1756-TBS6H

1756-OB16D 16 diagnostic outputs(8 pointsgroup)

24V DC source 19230V DC 1756-TBCH1756-TBS6H

1756-OB16E 16 electronically fused outputs(8 pointsgroup)

1224V DC source 10312V DC 1756-TBNH1756-TBSH

1756-OB16I 16 individually isolated outputs

1224V DC sinksource 1030V DC 1756-TBCH1756-TBS6H

1756-OB16IS 16 individually isolated outputs8 scheduled outputs

1224V DC sinksource 1030V DC 1756-TBCH1756-TBS6H

1756-OB32 32 outputs(16 pointsgroup)

1224V DC source 10312V DC 1756-TBCH1756-TBS6H

Publication 1756-SG001P-EN-P - May 2011 9

Contact Output Modules

Analog Input Modules

1756-OC8 8 outputs(4 pointsgroup)

48V DC source 3060V DC 1756-TBNH1756-TBSH

1756-OG16 16 (8 pointsgroup) 5V DC TTL source (Low=True)

4555V DC 1756-TBNH1756-TBSH

1756-OH8I 8 outputsindividually isolated

120V DC 90146V DC 1756-TBCH1756-TBS6H

1756-OV16E 16 electronically fused outputs(8 pointsgroup)

1224V DC sink 1030V DC 1756-TBNH1756-TBSH

1756-OV32E 32 electronically fused outputs (16 pointsgroup)

1224V DC sink 1030V DC 1756-TBCH1756-TBS6H

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

Cat No InputsOutputs Operating Voltage Range Removable Terminal Block

1756-OW16I 16 normally open individually isolated outputs 5150V DC10265V AC

1756-TBCH1756-TBS6H

1756-OX8I 8 normally open8 normally closed individually isolated outputs(2 pointsgroup)

5150V DC10265V AC

1756-TBCH1756-TBS6H

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-IF6CIS 6 individually isolated inputs current sourcing

0hellip21 mA 16 bits034 Abit

1756-TBNH1756-TBSH

1756-IF6I 6 individually isolated inputs plusmn105V0hellip105V0hellip525V0hellip21 mA

16 bits105V 343 Vbit0hellip105V 171 Vbit0hellip525V 86 Vbit0hellip21 mA 034 Abit

1756-TBNH1756-TBSH

1756-IF8 8 single-ended inputs4 differential inputs2 high-speed differential inputs

plusmn1025V01025V05125V0hellip205 mA

plusmn1025V 320 Vcnt (15 bits plus sign bipolar)0hellip1025V 160 Vcnt (16 bits)0hellip5125V 80 V cnt (16 bits)0hellip205mA 032 Acnt (16 bits)

1756-TBCH1756-TBS6H

10 Publication 1756-SG001P-EN-P - May 2011

Analog RTD and Thermocouple Modules

Analog Output Modules

1756-IF8H 8 differential voltage or current inputs HART interface

plusmn10V05V1hellip5V010V0hellip20 mA4hellip20 mA

16hellip21 bits 1756-TBCH1756-TBS6H

1756-IF16 16 single-ended inputs8 differential or 4 differential (high speed) inputs

plusmn105V0hellip105V0hellip525V0hellip21 mA

16 bits105V 343 Vbit0hellip105V 171 Vbit0hellip525V 86 Vbit0hellip21 mA 034 Abit

1756-TBCH1756-TBS6H

1756-IF16H 16 differential current inputs HART interface

0hellip20 mA4hellip20 mA

16hellip21 bits 1756-TBCH1756-TBS6H

Cat No InputsOutputs Range Resolution Removable Terminal Block

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-IR6I 6 individually isolated RTD inputs 1hellip487 2hellip1000 4hellip20008hellip4020

16 bits1hellip487 77 mbit2hellip1000 15 mbit4hellip2000 30 mbit8hellip4020 60 mbit

1756-TBNH1756-TBSH

1756-IT6I 6 individually isolated thermocouple inputs1 CJC

-12hellip78 mV-12hellip30 mV

16 bits-1278 mV 14 Vbit-1230 mV 07 Vbit

1756-TBNH1756-TBSH

1756-IT6I2 6 individually isolated thermocouple inputs2 CJC

-12hellip78 mV (14 V per bit)-12hellip30 mV (07 V per bit ndash high resolution range)

16 bits-1278 mV 14 Vbit-1230 mV 07 Vbit

1756-TBNH1756-TBSH

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-OF4 4 voltage or current outputs plusmn104V0hellip21 mA

Voltage15 bits across 105V 320 VbitCurrent15 bits across 21mA 650 nAbit

1756-TBNH1756-TBSH

1756-OF6CI 6 individually isolated outputs current

0hellip21 mA 13 bits across 21 mA (27 A) 1756-TBNH1756-TBSH

1756-OF6VI 6 individually isolated outputs voltage

plusmn105V 14 bits across 21V (13 mV)(13 bits across 105V +sign bit)

1756-TBNH1756-TBSH

1756-OF8 8 voltage or current outputs plusmn104V0hellip21 mA

15 bits across 21 mA - 650 nAbit15 bits across 104V - 320 Vbit

1756-TBNH1756-TBSH

1756-OF8H 8 voltage or current outputs HART interface

plusmn104V0hellip20 mA4hellip20 mA

15hellip16 bits 1756-TBNH1756-TBSH

Publication 1756-SG001P-EN-P - May 2011 11

Analog Combination Input and Output Module

Specialty IO Modules

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-IF4FXOF2F 4 high-speed sub-millisecond differential inputs2 high-speed voltage or current outputs

Inputplusmn105V0hellip105V0hellip525V0hellip21 mAOutputplusmn104V0hellip21 mA

InputApprox 14 bits across plusmn10V DC (21V total)plusmn10V 13 mVbit 14-bit effective0hellip105V 13 mVbit 13-bit effective0hellip525V 13 mVbit 12-bit effectiveApprox 12 bits across 21 mA0hellip21 mA 525 AbitOutput13 bits across 21 mA = 28 Abit14 bits across 218V = 13 mVbit

1756-TBCH1756-TBS6H

Cat No InputsOutputs Description Removable Terminal Block

1756-CFM 4 inputs (2 per channel) 2 outputs current sourcing

Configurable flowmeter module2 Flowmeter (F) inputs used for all modes2 Gate inputs used in Totalizer mode for proverstore count

1756-TBNH1756-TBSH

1756-HSC 2 counters each with 3 inputs (A B Z for gatereset)4 outputs (2 pointsgroup)

High-speed counter module5V operation 45hellip55V DC1224V operation 10hellip312V DC

1756-TBCH1756-TBS6H

1756-PLS Left section 2 groups of 4 outputs and 4 inputs eachCenter section resolver interface and IO controlRight section 2 groups of 4 outputs and 4 inputs each

Programmable limit switch module Requires 3 RTBs 1756-TBNH or 1756-TBSH

12 Publication 1756-SG001P-EN-P - May 2011

HART Smart Instrumentation

HART (Highway Addressable Remote Transmitter) is an open protocol designed to connect analog devices For HART connectivity select from products available from Rockwell Automation and our Encompass partners

Typical HART Configuration

HART Interfaces

Accessories - IO Modules

1756 Removable Terminal Blocks

Removable terminal blocks (RTBs) provide a flexible interconnection between your plant wiring and 1756 IO modules The RTB plugs into the front of the IO module The type of module determines which RTB you need You can choose screw-clamp or spring-clamp RTBs

RTBs are not shipped with IO modules You must order them separately The standard housing on the front of the wiring arm is not deep enough for 25 mm2

HART Devices

ControlLogix Controller with 1756-IF8H or 1756-OF8H module

If your application has Select Description

Analog and HART connectivity in one moduleNo external hardware required to access HART signalHART commands can be transmitted as unscheduled messagesSupports asset management software to HART device

1756-IF8H1756-IF16H1756-OF8H

Rockwell Automation analog IO modules

Data acquisition or control application with slow update requirements (such as a tank farm)No external hardware required to access HART signalDoes not connect directly to asset management software

MVI56-HART Prosoft interface

Analog and HART in one moduleInstrumentation in hazardous locations (FLEX Ex modules)HART commands can be transmitted as unscheduled messagesDirectly connects asset management software to HART devices

1794 FLEX IO1797 FLEX Ex IO

There are specific FLEX IO and FLEX Ex modules designed for HART systems These catalog numbers end in an H such as 1797-IE8H

Publication 1756-SG001P-EN-P - May 2011 13

(14 AWG) wiring If you plan to use 25 mm2 (14 AWG) wiring also order the extended housing

Wiring Systems

As an alternative to buying RTBs and connecting the wires yourself you can buy a wiring system of the following

Interface modules (IFMs) that provide the output terminal blocks for digital IO modules Use the pre-wired cables that match the IO module to the IFM

Analog interface modules (AIFMs) that provide the output terminal blocks for analog IO modules Use the pre-wired cables that match the IO module to the AIFM

IO module-ready cables One end of the cable assembly is an RTB that plugs into the front of the IO module The other end has individually color-coded conductors that connect to a standard terminal block

Attribute 1756-TBNH 1756-TBSH 1756-TBCH 1756-TBS6H 1756-TBE

Description 20-position NEMA screw-clamp removable block

20-pin spring-clamp removable terminal block with standard housing

36-pin cage-clamp removable terminal block with standard housing

36-pin spring-clamp removable terminal block with standard housing

Extended depth terminal block housing

Screw torque 08hellip1 Nbullm7hellip9 lbbullin

04 Nbullm44 lbbullin

mdash

Screwdriver width 8 mm (516 in) max

IO Module

RTBPre-wired Cable

Factory-wired

Interface Module (IFM)

Field Wiring

14 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Integrated Motion

The Logix architecture supports motion control components that work in a wide variety of machine architectures

Integrated motion on EtherNetIP supports a connection to Ethernet drives

The Kinetix integrated-motion solution uses a SERCOS interface module to perform multi-axis synchronized motion

Logix integrated motion supports the analog family of servo modules for controlling drivesactuators

Networked motion provides the ability to connect via the DeviceNet network to a single axis drive to perform point-to-point indexing

For detailed specifications on motion interface modules see 1756 ControlLogix Integrated Motion Specifications publication 1756-TD004

For more information see these publications

Motion Analyzer CD to size your motion application and to make final component selection Download the software from httpwwwabcommotionsoftwareanalyzerhtml

Kinetix Motion Control Selection Guide publication GMC-SG001 to verify drive motor and accessory specifications

Integrated Motion on an EtherNetIP Network

Product Consideration

Drive that supports EtherNetIP connections Unlimited velocity torque and Vhz configured drives Kinetix 6500 drives PowerFlex 755 drives

ControlLogix controller As many as 100 drives per controller

ControlLogix EtherNetIP communication module 1hellip8 position configured drives with 1756-EN2TR module 1hellip255 position configured drives with 1756-EN3TR module

Publication 1756-SG001P-EN-P - May 2011 15

SERCOS Interface Modules

The SERCOS interface modules can connect to these servo drives

2093 Kinetix 2000 multi-axis servo drive 2094 Kinetix 6000 multi-axis servo drive 2099 Kinetix 7000 high-power servo drive 2098 Ultra3000 SERCOS servo drive

ControlLogix Controller

PanelView Plus Terminal

Workstations

POINT IO ModulesDrive with EtherNetIP Connection

Cat No Description Number of Axis

1756-M16SE Rockwell Automation SERCOS interface modules 16

1756-M08SE 8

1756-M03SE 3

1756-M08SEG SERCOS interface drives that are Extended Pack Profile compliant 8

16 Publication 1756-SG001P-EN-P - May 2011

Analog Motion Interface Modules

RSLogix 5000 Software1756-MxxSE Module

ControlLogix Controller

Three-phase Input Power

Line Interface Module

Integrated Axis Module

Motor Motor Feedback

Axis Modules

Slot Filler Module

Shunt Module

SERCOS Fiber-optic RingKinetix 6000 Multi-axis Servo Drive

Cat No Description Number of Axis

1756-M02AE Analog servo interface drives with quadrature feedback 2

1756-HYD02 Analog hydraulic servo interface drives LDT feedback 2

1756-M02AS Analog servo interface drives with SSI feedback 2

Publication 1756-SG001P-EN-P - May 2011 17

ControlLogix Communication Modules

Separate communication modules are available for different networks Install multiple communication modules into the ControlLogix backplane to bridge or route control and information data between different networks You can route a message through a maximum of four chassis (eight communication hops) You do not need a ControlLogix controller in the chassis

For detailed specifications see 1756 ControlLogix Network Specifications publication 1756-TD003

Application Network Page

Plant management (material handling) Configuration data collection and control on a single high-speed network Time-critical applications with no established schedule Inclusion of commercial technologies (such as video over IP) InternetIntranet connection Integrated CIP motion and safety

EtherNetIP network 19

High-speed transfer of time-critical data between controllers and IO devices Deterministic and repeatable data delivery Media redundancy Intrinsic safety Redundant controller systems

ControlNet network 20

Connections of low-level devices directly to plant floor controllers without interfacing them through IO modules

Data sent as needed More diagnostics for improved data collection and fault detection Less wiring and reduced start-up time than a traditional hard-wired system

DeviceNet network 21

Plant-wide and cell-level data sharing with program maintenance Data sent regularly Transfer of information between controllers

Data Highway Plus network 23

Connections between controllers and IO adapters Data sent regularly Distributed control so that each controller has its own IO and communicates with a

supervisory controller

Remote IO network 23

Fieldbus transmitters and actuators Closed-loop control Process automation

Foundation Fieldbus network 25

18 Publication 1756-SG001P-EN-P - May 2011

EtherNetIP Communication Modules

The Ethernet Industrial (EtherNetIP) network protocol is an open industrial-networking standard that supports both real-time IO messaging and message exchange The EtherNetIP network uses off-the-shelf Ethernet communication chips and physical media

Accessories - EtherNetIP Network

Cat No Description Media Communication Rate

CIP Motion Axes max

TCPIP Connections

Logix Connections

1756-EN2F EtherNetIP bridge fiber Fiber 100 Mbps 8 128 256

1756-EN2T EtherNetIP bridge copper Copper 10100 Mbps 8 128 256

1756-EN2TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 8 128 256

1756-EN3TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 255 128 256

1756-ENBT EtherNetIP bridge copper Copper 10100 Mbps mdash 64 128

1756-EWEB Ethernet web server module Copper 10100 Mbps mdash 64 128

1756-EN2TXT ControlLogix-XT extended temperature EtherNetIP bridge copper for extreme environments

Copper 10100 Mbps 8 128 256

Cat No Description Specifications

1585J-M8PBJM-x Ethernet RJ45 patchcordx = 2 (2 m) 5 (5 m) or 10 (10 m)

8-conductor Teal Riser PVC Cable (Flex Rated cable also available)

1585J-M8CC-H RJ45 insulation displacement connector (IDC) 01280325 mm2 (26hellip22 AWG) Cat 6 IDC no tool required

1585J-M8CC-C RJ45 crimp connector with boot qty = 50 pieces 01280205 mm2 (26hellip24 AWG Cat 5e requires crimp tool for assembly

1585A-Jcrimp Crimp tool mdash

9300-RADES Remote access dial-in kit 56 Kbps modem connection to devices on an Ethernet network includes pre-configured modem communication module DIN rail mounting hardware associated cables

Publication 1756-SG001P-EN-P - May 2011 19

Example Configuration - EtherNetIP Network

ControlNet Communication ModulesThe ControlNet network combines the functionality of an IO network and a peer-to-peer network providing high-speed performance The ControlNet network provides deterministic repeatable transfers of critical control data

FirewallRouter

Stratix Switch

Stratix Switch

Stratix Switch

Powermonitor 3000PowerFlex 70

Ethernet PLC-5

MicroLogix

Ethernet SLC 500

1756 IO

1794 IO

1761-NET-ENI

ControlNet

DeviceNet

1734 IO

RSLinxPanelView Plus

1769-L35E CompactLogix

Cat No Description Communication Rate

Logix Connections Number of Nodes

1756-CN2B ControlNet bridge standard media 5 Mbps 128(1) 99

1756-CN2RB ControlNet bridge redundant media 5 Mbps 128(1) 99

1756-CNB ControlNet bridge standard media 5 Mbps 64(2) 99

1756-CNBR ControlNet bridge redundant media 5 Mbps 64(2) 99

1756-CN2RXT ControlLogix-XT extended temperature ControlNet bridge redundant media

5 Mbps 128(1) 99

(1) 128 connections are available for standard use An additional three connections are reserved for redundant control

(2) Recommend using only 4048 Logix connections for IO

20 Publication 1756-SG001P-EN-P - May 2011

Example Configuration - ControlNet Network

Example Configuration - Redundant ControlNet Media

For information on ControlNet media see ControlNet Media System Components List AG-PA002

DeviceNet Communication Module

The DeviceNet network provides connections between simple industrial devices (such as sensors and actuators) and higher-level devices (such as controllers and computers)

1784-U2CNPanelView Plus

1788-CN2DN

DeviceNetPowerFlex 700SPLC-540CControlLogix

Redundant Media

ControlLogix1756-CNBR

ControlNet Node

ControlNet Node

Cat No Description Communication Rate Number of Nodes

1756-DNB DeviceNet bridge 125 Kbps (500 m max)250 Kbps (250 m max)500 Kbps (100 m max)

64

Publication 1756-SG001P-EN-P - May 2011 21

Example Configuration - DeviceNet Network

Accessories - DeviceNet Network

PLC-51771-SDN ControlLogix

1756-DNB

Ultra3000

PanelView Plus1784-U2DN

Ultra5000

IO

Motor starter

PowerFlex AC

Sensor Pushbuttons

LightsBar Code Scanner

Cat No Description

KwikLink Lite flat media KwikLink Lite flat media is a newer ODVA-approved solution for wiring DeviceNet networks Drop-lines for connecting nodes are added by using the KwikLink Lite two-piece connectors This cable system supports the intermixing of DeviceNet cable types (thin-round with flat) All of the KwikLink Lite connectors provide insulation displacement technology with reduced assembly time

KwikLink flat media The KwikLink flat media system provides a modular cabling method with its flat 4-wire cable and insulation displacement connectors (IDCs) The KwikLink system allows nodes to be added to the network without severing the trunkline Cutting or stripping of the trunkline is eliminated as is the need for predetermined cable lengths

Round media Round trunk cable is available in bulk spools or as pre-molded cordsets or patchcords in varying lengths A wide variety of rugged durable DeviceNet components is available for use in round trunk systems Stainless steel versions of round cable system components are also available Thick-trunk round media systems use thick cable for maximum DeviceNet trunk line length Round media thin-trunk systems use thin cable to reduce maximum trunk line distances with a more

compact and cost-effective installation for some applications Thin-cable outer jacket material is TPE for additional chemical resistance

22 Publication 1756-SG001P-EN-P - May 2011

Data Highway Plus and Remote IO Communication Modules

The Data Highway Plus network supports messaging between devices The remote IO link connects to remote IO chassis and other intelligent devices

The 1756-DHRIO module supports messaging between devices on DH+ networks The remote IO functionality enables the module to act as a scanner for transferring digital and block-transfer data to and from remote IO devices

The 1756-RIO module can act as a scanner or adapter on a remote IO network In addition to digital and block-transfer data the 1756-RIO module transfers analog and specialty data without message instructions

Cat No Description Communication Rate DH+ Connections RIO Connections Maximum Recommended Logix Connections

1756-DHRIO Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

1756-RIO Remote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

mdash Remote IO scanner or adapter32 physical racks (076) any combination of rack size and block transfers

10 scheduled IO

1756-DHRIOXT ControlLogix-XT extended temperature Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

Publication 1756-SG001P-EN-P - May 2011 23

Example Configuration - DH+ Network

Example Configuration - Remote IO Network

Accessories - DH+ and Remote IO Networks

PanelView Plus

PLC-5 1784-U2DHPRSLogix 5000

ControlLogix1756-DHRIO

SLC 504

PanelView PlusPLC-5

1791 IO1794 IO

1756-RIO as a Remote IO Adapter

1756-DHRIO as a Remote IO Scanner

Cat No Description Specifications

1770-CD Cable to connect communication module to DH+ network Belden 9463 twinaxial

9300-RADKIT Remote access dial-in kit 56 Kbps modem connection to devices on a DH+ network includes pre-configured modem communication module DIN rail mounting hardware associated cables

24 Publication 1756-SG001P-EN-P - May 2011

FOUNDATION Fieldbus Linking Devices

The FOUNDATION Fieldbus protocol is a network designed for distributed control of process applications

Example Configuration - Bridge to EtherNetIP Network

Cat No Description Communication Rate Number of H1 Ports

Devices per H1 Link

Devices per Linking Device

1757FFLD2 FOUNDATION Fieldbus bridge to an Ethernet network

FOUNDATION Fieldbus 3125 KbpsEtherNetIP 10100 Mbps

2 16(8hellip10 recommended)

32

1757-FFLD4 4 64

1757-FFLDC2 FOUNDATION Fieldbus bridge to a ControlNet network

FOUNDATION Fieldbus 3125 KbpsControlNet 5 Mbps

2 16(8hellip10 recommended)

32

1757-FFLDC4 4 64

FactoryTalk View SERSFieldbusRSLogix 5000

1757-FFLD4

H1(1)

H1(2)H1(3)H1(4)

HSEIP

Publication 1756-SG001P-EN-P - May 2011 25

Example Configuration - Bridge to ControlNet Network

Other Connectivity Options

ControlLogix RedundancyFactoryTalk View SERSFieldbusRSLogix 5000

ControlNet Redundant Media

1757-FFLDC2

FF H1

EtherNetIP

Option Consideration

USB connection The 1756-L7x controller has a USB port in place of the serial port If your application requires RS-232 functionality see the many Encompass partners at httpwwwrockwellautomationcomencompass

Serial connection The serial port on the 1756-L6x controller is compatible with RS-232 serial communication The serial port supports the DF1 protocol to communicate with other devices on the serial linkTo use Logix5000 controllers on Modbus you connect through the serial port and execute a specific ladder logic routine The controller project is available with RSLogix 5000 Enterprise programming software For more information see Using Logix5000 Controllers as Masters or Slaves on Modbus Application Solution publication CIG-AP129

DH-485 network The controller serial port is compatible with DH-485 communication The DH-485 connection does support remote programming and monitoring via RSLogix 5000 softwareOr add a DH-485 communication bridge module (cat no 1756-DH485)

SynchLink network The SynchLink communication module (1756-SYNCH) provides time synchronization and data broadcasting capabilities for distributed motion and coordinated drive control The module connects a ControlLogix chassis to a SynchLink fiber-optic communication link

26 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Controllers The ControlLogix controller provides a scalable controller solution that is capable of addressing a large amount of IO points

The controller can be placed into any slot of a ControlLogix chassis and multiple controllers can be installed in the same chassis Multiple controllers in the same chassis communicate with each other over the backplane (just as controllers can communicate over networks) but operate independently

ControlLogix controllers can monitor and control IO across the ControlLogix backplane as well as over IO links ControlLogix controllers can communicate over EtherNetIP ControlNet DeviceNet DH+ Remote IO and RS-232-C (DF1DH-485 protocol) networks and many third party process and device networks To provide communication for a ControlLogix controller install the appropriate communication interface module into the chassis

For detailed specifications see 1756 ControlLogix Controllers Specifications publication 1756-TD001

Cat No Description User Memory

1756-L72 ControlLogix controller 1 built-in USB port 4 MB

1756-L73 8 MB

1756-L74 16 MB

1756-L75 32 MB

1756-L61 ControlLogix controller 1 built-in RS-232 port 2 MB

1756-L62 4 MB

1756-L63 8 MB

1756-L64 16 MB

1756-L65 32 MB

1756-L61S GuardLogix safety controller 2 MB standard1 MB safety

1756-L62S 4 MB standard1 MB safety

1756-L63S 8 MB standard375 MB safety

1756-LSP GuardLogix safety partner (one is required for each GuardLogix controller) mdash

1756-L63XT ControlLogix-XT controller extreme environment 8 MB

IMPORTANT Scan time for a project loaded in a 1756-L64 or 1756-L65 controller may be slower than for the same project loaded in one of the other 1756-L6x controllers See the Logix5000 Controllers Instruction Execution Time and Memory Use Reference Manual publication 1756-RM087 for instruction execution times

Publication 1756-SG001P-EN-P - May 2011 27

Standard ControlLogix Controllers

The ControlLogix controller is part of the Logix5000 family of controllers A ControlLogix system includes the following

The ControlLogix controller available in different combinations of user memory

RSLogix 5000 programming software 1756 ControlLogix IO modules that reside in a 1756 chassis Separate communication modules for network communication

Features - Standard ControlLogix Controllers

Feature 1756-L61 1756-L62 1756-L63 1756-L64 1756-L65

1756-L72 1756-L73 1756-L74 1756-L75

Controller tasks 32 tasks 100 programstask Event tasks all event triggers

Built-in communication ports 1 port RS-232 serial 1 port USB

Communication options EtherNetIP ControlNet DeviceNet Data Highway Plus Remote IO SynchLink Third-party process and device networks

Built-in port Serial USB

Controller connections supported max 250 500

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Full support

Integrated motion EtherNetIP connection SERCOS interface Analog options (encoder input LDT input SSI input)

Programming languages Relay ladder Structured text Function block SFC

28 Publication 1756-SG001P-EN-P - May 2011

GuardLogix Controllers

A GuardLogix controller is a ControlLogix controller that also provides safety control The GuardLogix system is a dual controller solutionmdashyou must use a 1756-L6xS primary controller and a 1756-LSP safety partner to achieve SIL 3CAT 4

During development safety and standard have the same rules multiple programmers online editing and forcing are all allowed Once the project is tested and ready for final validation you set the Safety Task to a SIL 3 integrity level which is then enforced by the GuardLogix controller When safety memory is locked and protected the safety logic cant be modified and all safety functions operate with SIL 3 integrity On the standard side of the GuardLogix controller all functions operate like a regular Logix controller

Use Guard IO modules for field device connectivity on Ethernet or DeviceNet networks and for safety interlocking between GuardLogix controllers use Ethernet or ControlNet networks Multiple GuardLogix controllers can share safety data for zone to zone interlocking or a single GuardLogix controller can use remote distributed safety IO between different cellsareas

In addition to the standard features of a ControlLogix controller the GuardLogix controller has these safety-related features

Application Description

SIL 1 2 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508 and applications up to and including PLeCat4 according to ISO 13849-1 For more information see GuardLogix Controllers Systems Safety Reference Manual publication 1756-RM093 GuardLogix Controllers User Manual publication 1756-UM020 GuardLogix Safety Application Instruction Set Reference Manual publication 1756-RM095

Features - GuardLogix Controllers

Feature 1756-L61S 1756-L62S 1756-L63S 1756-LSP

Safety communication options Standard and safety EtherNetIP ControlNet DeviceNet

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Not supported

Programming languages Relay ladder

Publication 1756-SG001P-EN-P - May 2011 29

ControlLogix-XT Controllers

The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh corrosive environments

When used with FLEX IO-XT products the ControlLogix-XT system can withstand temperatures range from -2070 C (-4158 F)

When used independently the ControlLogix-XT system can withstand temperature ranges from -2570 C (-13158 F)

Redundant ControlLogix Controllers

The ControlLogix controller supports controller redundancy In a redundant controller system you need these components

Two 1756 chassis each with the following the same ndash Number of slots

ndash Modules in the same slots

ndash Redundancy firmware revisions in each module

ndash Two additional ControlNet nodes outside the redundant chassis pair

You need one of these redundancy modules

One 1756-RM module per chassis that supports the followingndash Two 1756-L61 1756-L62 1761-L63 controllers or one 1756-L64

controller

ndash Maximum of seven communication modules which can be 1756-CN2 series B 1756-CN2R series B and 1756-EN2T modules

ndash One 1756-RMCx cable

One 1757-SRM module per chassis that supports the followingndash One 1756-L61 1756-L62 1756-L63 1756-L64 controller

ndash Maximum of seven communication modules which can be 1756-CNB series D or E 1756-CNBR series D or E 1756-ENBT and 1756-EWEB modules

ndash One 1757-SRCx cable

30 Publication 1756-SG001P-EN-P - May 2011

Accessories - Controllers

Memory Cards

Memory cards offer nonvolatile memory to permanently store a user program and tag data on a controller The 1756-L7x ControlLogix controller comes with 1784-SD1 Secure Digital (SD) card already installed The 1756-L6x controllers support optional CompactFlash cards that you purchase separately The memory card installs in a socket on the controller Through RSLogix 5000 software you can manually trigger the controller to save to or load from nonvolatile memory or configure the controller to load from nonvolatile memory on powerup

The GuardLogix controller does not support user program storage or retrieval by using a CompactFlash card

1756 Energy Storage Modules

Instead of a battery the 1756-L7x controller ships with a 1756-ESMCAP energy storage module (ESM) already installed

Attribute 1784-CF64 1784-CF128 1784-SD1 1784-SD2

Memory 64 MB 128 MB 1 GB 2 GB

Supported controllers 1756-L6x 1756-L7x

Weight approx 142 g (05 oz) 176 g (0062 oz)

Cat No Description

1756-ESMCAP Capacitor-based energy-storage module Comes with the controller

1756-EMNSE ESM without WallClockTime backup power Additionally you can use this ESM with a 1756-L73 (8 MB) or smaller memory-sized controller only

Use this ESM if your application requires that the installed ESM deplete its residual energy to 40 microJoule or less before transporting it into or out of your application

1756-ESMNRM Energy-storage module that secures the controller by preventing the USB connection and SD card useThis ESM provides your application an enhanced degree of security

Publication 1756-SG001P-EN-P - May 2011 31

1756 ControlLogix Batteries

Each 1756-L6x controller ships with a battery With a memory card installed the controller can be used without a battery If you do not use a battery current tag data will be at the state it was when the memory card was saved

ControlLogix Chassis The ControlLogix system is a modular system that requires a 1756 IO chassis Place any module into any slot The backplane provides a high-speed communication path between modules

All of the chassis are designed for horizontal-only back-panel mounting The chassis are available in these configurations

Standard chassis ControlLogix-XT chassis

For detailed specifications see 1756 ControlLogix Chassis Specifications Specifications publication 1756-TD006

Features - Chassis

Slot guides and snap-in retention for easy and secure module fit for any type of 1756 module

Direct mounting accommodates any 1756 power supply

Attribute 1756-BA1 1756-BA2 1756-BATM(1) 1756-BATA

Description Lithium battery (059 g) Lithium battery (059 g) Externally mounted battery assembly

Replacement lithium battery for 1756-BATM (5 g max lithium per each D cell contains 2 D cells)

ControlLogix controllers 1756-L61 1756-L62 1756-L63 series A

1756-L61 1756-L62 1756-L63 series B1756-L64 1756-L65

1756-L61 1756-L62 1756-L63 series A

1756-BATM battery module

GuardLogix controllers mdash 1756-L61S 1756-L62S 1756-L63S

mdash mdash

ControlLogix-XT controllers

mdash 1756-L63XT mdash mdash

(1) The 1756-BATM externally mounted battery assembly is highly recommended for use with all series A 1756-L6x controllers and provides longer battery life than the 1756-BA1 battery The 1756-BATM includes one 1756-BATA lithium battery assembly and a 1 m (328 ft) cable to connect housing to controller

32 Publication 1756-SG001P-EN-P - May 2011

Standard Chassis

The chassis backplane provides a high-speed communication path between modules and distributes power to each of the modules within the chassis

ControlLogix-XT Chassis

The ControlLogix-XT chassis support extreme temperature environments

Accessories - Chassis

Use a slot filler module to fill empty slots

Cat No Description Slots

1756-A4 ControlLogix standard chassis 4

1756-A7 7

1756-A10 10

1756-A13 13

1756-A17 17

Cat No Description Slots Temperature Range

1756-A4LXT ControlLogix-XT chassis 4 -2560 degC (-13140 degF)

1756-A5XT 5 -2570 degC (-13158 degF)

1756-A7LXT 7 -2560 degC (-13140 degF)

Cat No Description

1756-N2 Slot filler module for empty slots in standard ControlLogix chassis

1756-N2XT Slot filler module for empty slots in ControlLogix-XT chassis

Publication 1756-SG001P-EN-P - May 2011 33

ControlLogix Power Supplies

ControlLogix power supplies are used with the 1756 chassis to provide 12V 33V 5V and 24V DC power directly to the chassis backplane Select from these configurations

Standard power Redundant power ControlLogix-XT power

For detailed specifications see 1756 ControlLogix Power Supplies Specifications publication 1756-TD005

Standard Power Supplies

You mount a standard power supply directly on the left end of the chassis where it plugs directly into the backplane

ControlLogix-XT Power Supplies

The ControlLogix-XT power supplies support extreme temperature environments

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA72 ControlLogix standard AC 120V220V AC 85hellip265V AC Standard series A and series B

1756-PA75 120V220V AC 85hellip265V AC Standard series B

1756-PB72 ControlLogix standard DC 24V DC 18hellip32V DC Standard series A and series B

1756-PB75 24V DC 1832V DC Standard series B

1756-PC75 48V DC 30hellip60V DC Standard series B

1756-PH75 125V DC 90hellip143V DC Standard series B

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PAXT ControlLogix-XT AC power supply 85265V AC 120240V AC XT

1756-PBXT ControlLogix-XT DC power supply 24V DC 18hellip32V DC XT

34 Publication 1756-SG001P-EN-P - May 2011

Redundant Power Supplies

To build a redundant power supply system you need the following

Two redundant power supplies (both 1756-PA75R or 1756-PB75R) One 1756-PSCA2 chassis adapter module Two 1756-CPR2 cables to connect the power supplies to the

1756-PSCA2 chassis adapter module (091 m (3 ft) length) User-supplied annunciator wiring to connect the power supplies to the

input modules as needed

The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Accessories - Redundant Power Supplies

Visualization Products Visualization products together with Logix for control and NetLinx architecture for communication make up the Rockwell Automation Integrated Architecture strategy The visualization strategy combines Rockwell Automation expertise in Allen-Bradley electronic operator interface and industrialized personal computer hardware with Rockwell Software supervisory control software Current visualization products include the following

FactoryTalk View software PanelView Plus operator interface PanelView Plus CE operator interface Industrial computers and monitors

For more information see the Operator Interface catalog pages at httpwwwabcomenepubcatalogs1276221813761239781

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA75R ControlLogix redundant 120V220V AC 85hellip265V AC Standard series B

1756-PB75R 24V DC 192hellip32V DC Standard series B

Cat No Description Specifications

1756-PSCA2 Chassis adapter module Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Mounts directly to left side of 1756 chassis

1756-CPR2 Chassis adapter cable Connects redundant power supply to 1756-PCSA2 chassis adapter Length091 m (3 ft)

Publication 1756-SG001P-EN-P - May 2011 35

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

ControlLogix System Overview

The ControlLogix system provides discrete drives motion process and safety control together with communication and state-of-the-art IO in a small cost-competitive package The system is modular so you can design build and modify it efficiently with significant savings in training and engineering

Example Configuration - ControlLogix System

A simple ControlLogix system consists of a standalone controller and IO modules in a single chassis For a more comprehensive system use the following

Multiple controllers in a single chassis Multiple controllers joined across networks IO in multiple platforms that are distributed in many locations and

connected over multiple IO links

RUN IO

RS232

OK

FORCE

BAT

RUN REM PROG

Logix5564

OKCP

SERCOS

OKAB

OKIOMODNET OKIOMODNET

ST

ST

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

HART

ANALOG INPUT

OK

DIAGNOSTIC

FLT

ST

FLT

ST

0 1 2 3 4 5 6 7

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

8 9 10 11 12 13 14 15

DC OUTPUT

DIAGNOSTIC

FLT

ST

FLT

ST

0 1 2 3 4 5 6 7

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

8 9 10 11 12 13 14 15

DC INTPUT

POWER

STATUS

WDOG

BATT

NS

MODE

H1-1H1-2H1-3H1-4

DANGERDANGERDANGERDANGER

755

98

2

5

0

3

6

7

1

4

Logix55LSP

SAFETY

RUN

SAFETY

TASK

BAT OK

RUN IO

RS232

OK

FORCE

BAT

RUN REM PROG

Logix5561

Plant MRP SystemDatabaseTracking Systems

Laptop

Stratix 8000

POINT Guard IO

FLEX IO

PanelView Plus

PowerFlex 755

CompactBlock Guard IO

PowerFlex 70

Other Devices

EtherNetIP

Kinetix Servo Drive

Motor Feedback

Servo Motor

Motor Power

DeviceNet

FLEX IO-XT

Tower LightArmorBlock Guard IO

PowerFlex 70

Valve

Guard IO

HART

ControlNet

Flowmeter

LevelFoundation Fieldbus

1756

-L61

S17

56-L

SP17

56-L

64SE

RCOS

1756

-EN

2T17

56-C

N2

1756

-DN

BIO IO An

alog

4 Publication 1756-SG001P-EN-P - May 2011

ControlLogix-XT System

The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh corrosive environments

When used with FLEX IO-XT products the ControlLogix-XT system can withstand temperatures range from -2070 C (-4158 F)

When used independently the ControlLogix-XT system can withstand temperature ranges from -2570 C (-13158 F)

GuardLogix Safety System

A GuardLogix controller is a ControlLogix controller that also provides safety control The GuardLogix system is a dual controller solution mdash you must use a 1756-L6xS primary controller and a 1756-LSP safety partner to achieve SIL 3CAT 4 A major benefit of this system is that itrsquos still a single project safety and standard together The safety partner controller is a part of the system is automatically configured and requires no user setup

Application Description

SIL 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508 and applications up to and including category (CAT) 4 according to EN954-1 For more information see the following GuardLogix Controllers Systems Safety Reference Manual publication 1756-RM093 GuardLogix Controllers User Manual publication 1756-UM020 GuardLogix Safety Application Instruction Set Reference Manual publication 1756-RM095

SIL 2 Components of the ControlLogix system are type-approved and certified for use in SIL 2 applications according to IEC 61508 and AK4 applications according to DIN V19250 For a list of ControlLogix system components that meet SIL 2 requirements see Using ControlLogix in SIL 2 Applications Safety Reference Manual publication 1756-RM001

Publication 1756-SG001P-EN-P - May 2011 5

Example Configuration - Redundant ControlLogix System

The ControlLogix controller supports controller redundancy

OKAB

AB

DIAGNOSTIC

FLT

ST

FLT

ST

0 1 2 3 4 5 6 7

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

8 9 10 11 12 13 14 15

DC INTPUT

DIAGNOSTIC

FLT

ST

FLT

ST

0 1 2 3 4 5 6 7

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

8 9 10 11 12 13 14 15

DC OUTPUT

ST

ST

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

HART

ANALOG INPUT

OK

DIAGNOSTIC

FLT

ST

FLT

ST

0 1 2 3 4 5 6 7

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

8 9 10 11 12 13 14 15

DC INTPUT

DIAGNOSTIC

FLT

ST

FLT

ST

0 1 2 3 4 5 6 7

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

8 9 10 11 12 13 14 15

DC OUTPUT

ST

ST

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

HART

ANALOG INPUT

OK

POWER

OKAB

AB

OKCOMMPRI

REDUNDANCY MODULE

RUN IO

RS232

OK

FORCE

BAT

RUN REM PROG

Logix5564

RUN IO

RS232

OK

FORCE

BAT

RUN REM PROG

Logix5562

OKNETLINK

POWERPOWER

POWER

OKAB

AB

OKCOMMPRI

REDUNDANCY MODULE

RUN IO

RS232

OK

FORCE

BAT

RUN REM PROG

Logix5564

RUN IO

RS232

OK

FORCE

BAT

RUN REM PROG

Logix5562

OKNETLINK

ESC SEL

EOI or HMI

EtherNetIP or ControlNet

1756-RM

1756-EN2T

1756-CN2RB1756-RM

1756-L61 1756-L62 or 1756-L63

1756-EN2T

1756-CN2RB

Primary ControlLogix Chassis Secondary ControlLogix Chassis

Fiber Optic Cable

FLEX IO

1203-CN1

1336 Plus II AC Drive

1756-CNBR

1756-PA75R or 1756-PB75R Redundant Power Supplies Redundant ControlNet

ControlLogix IO1756-PSCA2 Chassis Adapter

1756-CPR2 Cables

1756-L61 1756-L62 or 1756-L63

6 Publication 1756-SG001P-EN-P - May 2011

Example Configuration - Redundant IO System

The 1715 redundant IO system lets a ControlLogix controller communicate to a remote redundant IO chassis over an EtherNetIP network The 1715 redundant IO system provides fault tolerance and redundancy for critical processes by using a redundant adapter pair and multiple IO modules that have diagnostics

The redundant IO system must be connected to a ControlLogix system via an EtherNetIP network All connections are established via the Ethernet network by using the topologies supported by the 1756-EN2TR communication bridge

For detailed specifications see the 1715 Redundant IO System Specifications Technical Data publication 1715-TD001A-EN-P

1756

-RM

1756

-EN

2TR

IO B

ASE

1715

-A31

0

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

IO B

ASE

1715

-A31

0

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

1715

-AEN

TR

1756

-EN

2TR

1756

-RM

1715

-AEN

TR

1715

-IO

1715

-IO

1715

-IO

1715

-IO

1715

-IO

1715

-IO

ControlLogix Primary Chassis ControlLogix Secondary Chassis

1715 Redundant IO System

Publication 1756-SG001P-EN-P - May 2011 7

ControlLogix IO Modules The ControlLogix architecture provides a wide range of input and output modules to span many applications from high-speed digital to process control The ControlLogix architecture uses a producerconsumer model so that input information and output status can be shared among multiple controllers

Each ControlLogix IO module mounts in a ControlLogix chassis and requires either a removable terminal block (RTB) or a 1492 interface module (IFM) to connect all field-side wiring RTBs and IFMs are not included with the IO modules They must be ordered separately

For detailed specifications see 1756 ControlLogix IO Modules Specifications publication 1756-TD002

AC Digital put Modules

AC Digital Output Modules

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

1756-IA8D 8 diagnostic inputs(4 pointsgroup)

120V AC 79hellip132V AC 1756-TBNH1756-TBSH

1756-IA16 16 inputs(8 pointsgroup)

120V AC 74hellip132V AC 1756-TBNH1756-TBSH

1756-IA16I 16 individually isolated inputs 120V AC 74hellip132V AC 1756-TBCH1756-TBS6H

1756-IA32 32 diagnostic inputs(4 pointsgroup)

120V AC 74hellip132V AC 1756-TBCH1756-TBS6H

1756-IM16I 16 individually isolated inputs 240V AC 159hellip265V AC 1756-TBCH1756-TBS6H

1756-IN16 16 inputs(8 pointsgroup)

24V AC 10hellip30V AC 1756-TBNH1756-TBSH

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

1756-OA8 8 outputs(4 pointsgroup)

120240V AC 79hellip265V AC 1756-TBNH1756-TBSH

1756-OA8D 8 diagnostic electronically fused outputs(4 pointsgroup)

120V AC 74hellip132V AC 1756-TBNH1756-TBSH

1756-OA8E 8 electronically fused outputs(4 pointsgroup)

120V AC 74hellip132V AC 1756-TBNH1756-TBSH

1756-OA16 16 mechanically fusedgroup outputs(8 pointsgroup)

120240V AC 74hellip265V AC 1756-TBNH1756-TBSH

1756-OA16I 16 individually isolated outputs

120240V AC 74hellip265V AC 1756-TBCH1756-TBS6H

1756-ON8 8 outputs(4 pointsgroup)

24V AC 10hellip30V AC current gt50 mA16hellip30V AC current lt50 mA

1756-TBNH1756-TBSH

8 Publication 1756-SG001P-EN-P - May 2011

DC Digital Input Modules

DC Digital Output Modules

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

1756-IB16 16 inputs(8 pointsgroup)

1224V DC sink 10312V DC 1756-TBNH1756-TBSH

1756-IB16D 16 diagnostic inputs(4 pointsgroup)

1224V DC sink 1030V DC 1756-TBCH1756-TBS6H

1756-IB16I 16 individually isolated inputs 1224V DC sinksource 1030V DC 1756-TBCH1756-TBS6H

1756-IB16ISOE 16 individually isolated sequence of events inputs

2448V DC sinksource 1055V DC 1756-TBCH1756-TBS6H

1756-IB32 32 inputs(16 pointsgroup)

1224V DC sink 10312V DC 1756-TBCH1756-TBS6H

1756-IC16 16 inputs(8 pointsgroup)

48V DC sink 3055V DC 60 degC (140 degC)3060V DC 55 degC (131 degC)

1756-TBNH1756-TBSH

1756-IG16 16 inputs(8 pointsgroup)

5V DC TTL source (Low=True)

4555V DC 1756-TBNH1756-TBSH

1756-IH16I 16 individually isolated inputs 125V DC sinksource 90146V DC 1756-TBCH1756-TBS6H

1756-IH16ISOE 16 individually isolated sequence of events inputs

125V DC sinksource 90140V DC 1756-TBCH1756-TBS6H

1756-IV16 16 inputs(8 pointsgroup)

1224V DC source 1030V DC 1756-TBNH1756-TBSH

1756-IV32 32 inputs(16 pointsgroup)

1224V DC source 1030V DC 1756-TBCH1756-TBS6H

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

1756-OB8 8 outputs 1224V DC source 1030V DC 1756-TBNH1756-TBSH

1756-OB8EI 8 electronically fused individually isolated outputs

1224V DC source 1030V DC 1756-TBCH1756-TBS6H

1756-OB8I 8 individually isolated outputs 1224V DC source 1030V DC 1756-TBCH1756-TBS6H

1756-OB16D 16 diagnostic outputs(8 pointsgroup)

24V DC source 19230V DC 1756-TBCH1756-TBS6H

1756-OB16E 16 electronically fused outputs(8 pointsgroup)

1224V DC source 10312V DC 1756-TBNH1756-TBSH

1756-OB16I 16 individually isolated outputs

1224V DC sinksource 1030V DC 1756-TBCH1756-TBS6H

1756-OB16IS 16 individually isolated outputs8 scheduled outputs

1224V DC sinksource 1030V DC 1756-TBCH1756-TBS6H

1756-OB32 32 outputs(16 pointsgroup)

1224V DC source 10312V DC 1756-TBCH1756-TBS6H

Publication 1756-SG001P-EN-P - May 2011 9

Contact Output Modules

Analog Input Modules

1756-OC8 8 outputs(4 pointsgroup)

48V DC source 3060V DC 1756-TBNH1756-TBSH

1756-OG16 16 (8 pointsgroup) 5V DC TTL source (Low=True)

4555V DC 1756-TBNH1756-TBSH

1756-OH8I 8 outputsindividually isolated

120V DC 90146V DC 1756-TBCH1756-TBS6H

1756-OV16E 16 electronically fused outputs(8 pointsgroup)

1224V DC sink 1030V DC 1756-TBNH1756-TBSH

1756-OV32E 32 electronically fused outputs (16 pointsgroup)

1224V DC sink 1030V DC 1756-TBCH1756-TBS6H

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

Cat No InputsOutputs Operating Voltage Range Removable Terminal Block

1756-OW16I 16 normally open individually isolated outputs 5150V DC10265V AC

1756-TBCH1756-TBS6H

1756-OX8I 8 normally open8 normally closed individually isolated outputs(2 pointsgroup)

5150V DC10265V AC

1756-TBCH1756-TBS6H

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-IF6CIS 6 individually isolated inputs current sourcing

0hellip21 mA 16 bits034 Abit

1756-TBNH1756-TBSH

1756-IF6I 6 individually isolated inputs plusmn105V0hellip105V0hellip525V0hellip21 mA

16 bits105V 343 Vbit0hellip105V 171 Vbit0hellip525V 86 Vbit0hellip21 mA 034 Abit

1756-TBNH1756-TBSH

1756-IF8 8 single-ended inputs4 differential inputs2 high-speed differential inputs

plusmn1025V01025V05125V0hellip205 mA

plusmn1025V 320 Vcnt (15 bits plus sign bipolar)0hellip1025V 160 Vcnt (16 bits)0hellip5125V 80 V cnt (16 bits)0hellip205mA 032 Acnt (16 bits)

1756-TBCH1756-TBS6H

10 Publication 1756-SG001P-EN-P - May 2011

Analog RTD and Thermocouple Modules

Analog Output Modules

1756-IF8H 8 differential voltage or current inputs HART interface

plusmn10V05V1hellip5V010V0hellip20 mA4hellip20 mA

16hellip21 bits 1756-TBCH1756-TBS6H

1756-IF16 16 single-ended inputs8 differential or 4 differential (high speed) inputs

plusmn105V0hellip105V0hellip525V0hellip21 mA

16 bits105V 343 Vbit0hellip105V 171 Vbit0hellip525V 86 Vbit0hellip21 mA 034 Abit

1756-TBCH1756-TBS6H

1756-IF16H 16 differential current inputs HART interface

0hellip20 mA4hellip20 mA

16hellip21 bits 1756-TBCH1756-TBS6H

Cat No InputsOutputs Range Resolution Removable Terminal Block

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-IR6I 6 individually isolated RTD inputs 1hellip487 2hellip1000 4hellip20008hellip4020

16 bits1hellip487 77 mbit2hellip1000 15 mbit4hellip2000 30 mbit8hellip4020 60 mbit

1756-TBNH1756-TBSH

1756-IT6I 6 individually isolated thermocouple inputs1 CJC

-12hellip78 mV-12hellip30 mV

16 bits-1278 mV 14 Vbit-1230 mV 07 Vbit

1756-TBNH1756-TBSH

1756-IT6I2 6 individually isolated thermocouple inputs2 CJC

-12hellip78 mV (14 V per bit)-12hellip30 mV (07 V per bit ndash high resolution range)

16 bits-1278 mV 14 Vbit-1230 mV 07 Vbit

1756-TBNH1756-TBSH

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-OF4 4 voltage or current outputs plusmn104V0hellip21 mA

Voltage15 bits across 105V 320 VbitCurrent15 bits across 21mA 650 nAbit

1756-TBNH1756-TBSH

1756-OF6CI 6 individually isolated outputs current

0hellip21 mA 13 bits across 21 mA (27 A) 1756-TBNH1756-TBSH

1756-OF6VI 6 individually isolated outputs voltage

plusmn105V 14 bits across 21V (13 mV)(13 bits across 105V +sign bit)

1756-TBNH1756-TBSH

1756-OF8 8 voltage or current outputs plusmn104V0hellip21 mA

15 bits across 21 mA - 650 nAbit15 bits across 104V - 320 Vbit

1756-TBNH1756-TBSH

1756-OF8H 8 voltage or current outputs HART interface

plusmn104V0hellip20 mA4hellip20 mA

15hellip16 bits 1756-TBNH1756-TBSH

Publication 1756-SG001P-EN-P - May 2011 11

Analog Combination Input and Output Module

Specialty IO Modules

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-IF4FXOF2F 4 high-speed sub-millisecond differential inputs2 high-speed voltage or current outputs

Inputplusmn105V0hellip105V0hellip525V0hellip21 mAOutputplusmn104V0hellip21 mA

InputApprox 14 bits across plusmn10V DC (21V total)plusmn10V 13 mVbit 14-bit effective0hellip105V 13 mVbit 13-bit effective0hellip525V 13 mVbit 12-bit effectiveApprox 12 bits across 21 mA0hellip21 mA 525 AbitOutput13 bits across 21 mA = 28 Abit14 bits across 218V = 13 mVbit

1756-TBCH1756-TBS6H

Cat No InputsOutputs Description Removable Terminal Block

1756-CFM 4 inputs (2 per channel) 2 outputs current sourcing

Configurable flowmeter module2 Flowmeter (F) inputs used for all modes2 Gate inputs used in Totalizer mode for proverstore count

1756-TBNH1756-TBSH

1756-HSC 2 counters each with 3 inputs (A B Z for gatereset)4 outputs (2 pointsgroup)

High-speed counter module5V operation 45hellip55V DC1224V operation 10hellip312V DC

1756-TBCH1756-TBS6H

1756-PLS Left section 2 groups of 4 outputs and 4 inputs eachCenter section resolver interface and IO controlRight section 2 groups of 4 outputs and 4 inputs each

Programmable limit switch module Requires 3 RTBs 1756-TBNH or 1756-TBSH

12 Publication 1756-SG001P-EN-P - May 2011

HART Smart Instrumentation

HART (Highway Addressable Remote Transmitter) is an open protocol designed to connect analog devices For HART connectivity select from products available from Rockwell Automation and our Encompass partners

Typical HART Configuration

HART Interfaces

Accessories - IO Modules

1756 Removable Terminal Blocks

Removable terminal blocks (RTBs) provide a flexible interconnection between your plant wiring and 1756 IO modules The RTB plugs into the front of the IO module The type of module determines which RTB you need You can choose screw-clamp or spring-clamp RTBs

RTBs are not shipped with IO modules You must order them separately The standard housing on the front of the wiring arm is not deep enough for 25 mm2

HART Devices

ControlLogix Controller with 1756-IF8H or 1756-OF8H module

If your application has Select Description

Analog and HART connectivity in one moduleNo external hardware required to access HART signalHART commands can be transmitted as unscheduled messagesSupports asset management software to HART device

1756-IF8H1756-IF16H1756-OF8H

Rockwell Automation analog IO modules

Data acquisition or control application with slow update requirements (such as a tank farm)No external hardware required to access HART signalDoes not connect directly to asset management software

MVI56-HART Prosoft interface

Analog and HART in one moduleInstrumentation in hazardous locations (FLEX Ex modules)HART commands can be transmitted as unscheduled messagesDirectly connects asset management software to HART devices

1794 FLEX IO1797 FLEX Ex IO

There are specific FLEX IO and FLEX Ex modules designed for HART systems These catalog numbers end in an H such as 1797-IE8H

Publication 1756-SG001P-EN-P - May 2011 13

(14 AWG) wiring If you plan to use 25 mm2 (14 AWG) wiring also order the extended housing

Wiring Systems

As an alternative to buying RTBs and connecting the wires yourself you can buy a wiring system of the following

Interface modules (IFMs) that provide the output terminal blocks for digital IO modules Use the pre-wired cables that match the IO module to the IFM

Analog interface modules (AIFMs) that provide the output terminal blocks for analog IO modules Use the pre-wired cables that match the IO module to the AIFM

IO module-ready cables One end of the cable assembly is an RTB that plugs into the front of the IO module The other end has individually color-coded conductors that connect to a standard terminal block

Attribute 1756-TBNH 1756-TBSH 1756-TBCH 1756-TBS6H 1756-TBE

Description 20-position NEMA screw-clamp removable block

20-pin spring-clamp removable terminal block with standard housing

36-pin cage-clamp removable terminal block with standard housing

36-pin spring-clamp removable terminal block with standard housing

Extended depth terminal block housing

Screw torque 08hellip1 Nbullm7hellip9 lbbullin

04 Nbullm44 lbbullin

mdash

Screwdriver width 8 mm (516 in) max

IO Module

RTBPre-wired Cable

Factory-wired

Interface Module (IFM)

Field Wiring

14 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Integrated Motion

The Logix architecture supports motion control components that work in a wide variety of machine architectures

Integrated motion on EtherNetIP supports a connection to Ethernet drives

The Kinetix integrated-motion solution uses a SERCOS interface module to perform multi-axis synchronized motion

Logix integrated motion supports the analog family of servo modules for controlling drivesactuators

Networked motion provides the ability to connect via the DeviceNet network to a single axis drive to perform point-to-point indexing

For detailed specifications on motion interface modules see 1756 ControlLogix Integrated Motion Specifications publication 1756-TD004

For more information see these publications

Motion Analyzer CD to size your motion application and to make final component selection Download the software from httpwwwabcommotionsoftwareanalyzerhtml

Kinetix Motion Control Selection Guide publication GMC-SG001 to verify drive motor and accessory specifications

Integrated Motion on an EtherNetIP Network

Product Consideration

Drive that supports EtherNetIP connections Unlimited velocity torque and Vhz configured drives Kinetix 6500 drives PowerFlex 755 drives

ControlLogix controller As many as 100 drives per controller

ControlLogix EtherNetIP communication module 1hellip8 position configured drives with 1756-EN2TR module 1hellip255 position configured drives with 1756-EN3TR module

Publication 1756-SG001P-EN-P - May 2011 15

SERCOS Interface Modules

The SERCOS interface modules can connect to these servo drives

2093 Kinetix 2000 multi-axis servo drive 2094 Kinetix 6000 multi-axis servo drive 2099 Kinetix 7000 high-power servo drive 2098 Ultra3000 SERCOS servo drive

ControlLogix Controller

PanelView Plus Terminal

Workstations

POINT IO ModulesDrive with EtherNetIP Connection

Cat No Description Number of Axis

1756-M16SE Rockwell Automation SERCOS interface modules 16

1756-M08SE 8

1756-M03SE 3

1756-M08SEG SERCOS interface drives that are Extended Pack Profile compliant 8

16 Publication 1756-SG001P-EN-P - May 2011

Analog Motion Interface Modules

RSLogix 5000 Software1756-MxxSE Module

ControlLogix Controller

Three-phase Input Power

Line Interface Module

Integrated Axis Module

Motor Motor Feedback

Axis Modules

Slot Filler Module

Shunt Module

SERCOS Fiber-optic RingKinetix 6000 Multi-axis Servo Drive

Cat No Description Number of Axis

1756-M02AE Analog servo interface drives with quadrature feedback 2

1756-HYD02 Analog hydraulic servo interface drives LDT feedback 2

1756-M02AS Analog servo interface drives with SSI feedback 2

Publication 1756-SG001P-EN-P - May 2011 17

ControlLogix Communication Modules

Separate communication modules are available for different networks Install multiple communication modules into the ControlLogix backplane to bridge or route control and information data between different networks You can route a message through a maximum of four chassis (eight communication hops) You do not need a ControlLogix controller in the chassis

For detailed specifications see 1756 ControlLogix Network Specifications publication 1756-TD003

Application Network Page

Plant management (material handling) Configuration data collection and control on a single high-speed network Time-critical applications with no established schedule Inclusion of commercial technologies (such as video over IP) InternetIntranet connection Integrated CIP motion and safety

EtherNetIP network 19

High-speed transfer of time-critical data between controllers and IO devices Deterministic and repeatable data delivery Media redundancy Intrinsic safety Redundant controller systems

ControlNet network 20

Connections of low-level devices directly to plant floor controllers without interfacing them through IO modules

Data sent as needed More diagnostics for improved data collection and fault detection Less wiring and reduced start-up time than a traditional hard-wired system

DeviceNet network 21

Plant-wide and cell-level data sharing with program maintenance Data sent regularly Transfer of information between controllers

Data Highway Plus network 23

Connections between controllers and IO adapters Data sent regularly Distributed control so that each controller has its own IO and communicates with a

supervisory controller

Remote IO network 23

Fieldbus transmitters and actuators Closed-loop control Process automation

Foundation Fieldbus network 25

18 Publication 1756-SG001P-EN-P - May 2011

EtherNetIP Communication Modules

The Ethernet Industrial (EtherNetIP) network protocol is an open industrial-networking standard that supports both real-time IO messaging and message exchange The EtherNetIP network uses off-the-shelf Ethernet communication chips and physical media

Accessories - EtherNetIP Network

Cat No Description Media Communication Rate

CIP Motion Axes max

TCPIP Connections

Logix Connections

1756-EN2F EtherNetIP bridge fiber Fiber 100 Mbps 8 128 256

1756-EN2T EtherNetIP bridge copper Copper 10100 Mbps 8 128 256

1756-EN2TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 8 128 256

1756-EN3TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 255 128 256

1756-ENBT EtherNetIP bridge copper Copper 10100 Mbps mdash 64 128

1756-EWEB Ethernet web server module Copper 10100 Mbps mdash 64 128

1756-EN2TXT ControlLogix-XT extended temperature EtherNetIP bridge copper for extreme environments

Copper 10100 Mbps 8 128 256

Cat No Description Specifications

1585J-M8PBJM-x Ethernet RJ45 patchcordx = 2 (2 m) 5 (5 m) or 10 (10 m)

8-conductor Teal Riser PVC Cable (Flex Rated cable also available)

1585J-M8CC-H RJ45 insulation displacement connector (IDC) 01280325 mm2 (26hellip22 AWG) Cat 6 IDC no tool required

1585J-M8CC-C RJ45 crimp connector with boot qty = 50 pieces 01280205 mm2 (26hellip24 AWG Cat 5e requires crimp tool for assembly

1585A-Jcrimp Crimp tool mdash

9300-RADES Remote access dial-in kit 56 Kbps modem connection to devices on an Ethernet network includes pre-configured modem communication module DIN rail mounting hardware associated cables

Publication 1756-SG001P-EN-P - May 2011 19

Example Configuration - EtherNetIP Network

ControlNet Communication ModulesThe ControlNet network combines the functionality of an IO network and a peer-to-peer network providing high-speed performance The ControlNet network provides deterministic repeatable transfers of critical control data

FirewallRouter

Stratix Switch

Stratix Switch

Stratix Switch

Powermonitor 3000PowerFlex 70

Ethernet PLC-5

MicroLogix

Ethernet SLC 500

1756 IO

1794 IO

1761-NET-ENI

ControlNet

DeviceNet

1734 IO

RSLinxPanelView Plus

1769-L35E CompactLogix

Cat No Description Communication Rate

Logix Connections Number of Nodes

1756-CN2B ControlNet bridge standard media 5 Mbps 128(1) 99

1756-CN2RB ControlNet bridge redundant media 5 Mbps 128(1) 99

1756-CNB ControlNet bridge standard media 5 Mbps 64(2) 99

1756-CNBR ControlNet bridge redundant media 5 Mbps 64(2) 99

1756-CN2RXT ControlLogix-XT extended temperature ControlNet bridge redundant media

5 Mbps 128(1) 99

(1) 128 connections are available for standard use An additional three connections are reserved for redundant control

(2) Recommend using only 4048 Logix connections for IO

20 Publication 1756-SG001P-EN-P - May 2011

Example Configuration - ControlNet Network

Example Configuration - Redundant ControlNet Media

For information on ControlNet media see ControlNet Media System Components List AG-PA002

DeviceNet Communication Module

The DeviceNet network provides connections between simple industrial devices (such as sensors and actuators) and higher-level devices (such as controllers and computers)

1784-U2CNPanelView Plus

1788-CN2DN

DeviceNetPowerFlex 700SPLC-540CControlLogix

Redundant Media

ControlLogix1756-CNBR

ControlNet Node

ControlNet Node

Cat No Description Communication Rate Number of Nodes

1756-DNB DeviceNet bridge 125 Kbps (500 m max)250 Kbps (250 m max)500 Kbps (100 m max)

64

Publication 1756-SG001P-EN-P - May 2011 21

Example Configuration - DeviceNet Network

Accessories - DeviceNet Network

PLC-51771-SDN ControlLogix

1756-DNB

Ultra3000

PanelView Plus1784-U2DN

Ultra5000

IO

Motor starter

PowerFlex AC

Sensor Pushbuttons

LightsBar Code Scanner

Cat No Description

KwikLink Lite flat media KwikLink Lite flat media is a newer ODVA-approved solution for wiring DeviceNet networks Drop-lines for connecting nodes are added by using the KwikLink Lite two-piece connectors This cable system supports the intermixing of DeviceNet cable types (thin-round with flat) All of the KwikLink Lite connectors provide insulation displacement technology with reduced assembly time

KwikLink flat media The KwikLink flat media system provides a modular cabling method with its flat 4-wire cable and insulation displacement connectors (IDCs) The KwikLink system allows nodes to be added to the network without severing the trunkline Cutting or stripping of the trunkline is eliminated as is the need for predetermined cable lengths

Round media Round trunk cable is available in bulk spools or as pre-molded cordsets or patchcords in varying lengths A wide variety of rugged durable DeviceNet components is available for use in round trunk systems Stainless steel versions of round cable system components are also available Thick-trunk round media systems use thick cable for maximum DeviceNet trunk line length Round media thin-trunk systems use thin cable to reduce maximum trunk line distances with a more

compact and cost-effective installation for some applications Thin-cable outer jacket material is TPE for additional chemical resistance

22 Publication 1756-SG001P-EN-P - May 2011

Data Highway Plus and Remote IO Communication Modules

The Data Highway Plus network supports messaging between devices The remote IO link connects to remote IO chassis and other intelligent devices

The 1756-DHRIO module supports messaging between devices on DH+ networks The remote IO functionality enables the module to act as a scanner for transferring digital and block-transfer data to and from remote IO devices

The 1756-RIO module can act as a scanner or adapter on a remote IO network In addition to digital and block-transfer data the 1756-RIO module transfers analog and specialty data without message instructions

Cat No Description Communication Rate DH+ Connections RIO Connections Maximum Recommended Logix Connections

1756-DHRIO Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

1756-RIO Remote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

mdash Remote IO scanner or adapter32 physical racks (076) any combination of rack size and block transfers

10 scheduled IO

1756-DHRIOXT ControlLogix-XT extended temperature Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

Publication 1756-SG001P-EN-P - May 2011 23

Example Configuration - DH+ Network

Example Configuration - Remote IO Network

Accessories - DH+ and Remote IO Networks

PanelView Plus

PLC-5 1784-U2DHPRSLogix 5000

ControlLogix1756-DHRIO

SLC 504

PanelView PlusPLC-5

1791 IO1794 IO

1756-RIO as a Remote IO Adapter

1756-DHRIO as a Remote IO Scanner

Cat No Description Specifications

1770-CD Cable to connect communication module to DH+ network Belden 9463 twinaxial

9300-RADKIT Remote access dial-in kit 56 Kbps modem connection to devices on a DH+ network includes pre-configured modem communication module DIN rail mounting hardware associated cables

24 Publication 1756-SG001P-EN-P - May 2011

FOUNDATION Fieldbus Linking Devices

The FOUNDATION Fieldbus protocol is a network designed for distributed control of process applications

Example Configuration - Bridge to EtherNetIP Network

Cat No Description Communication Rate Number of H1 Ports

Devices per H1 Link

Devices per Linking Device

1757FFLD2 FOUNDATION Fieldbus bridge to an Ethernet network

FOUNDATION Fieldbus 3125 KbpsEtherNetIP 10100 Mbps

2 16(8hellip10 recommended)

32

1757-FFLD4 4 64

1757-FFLDC2 FOUNDATION Fieldbus bridge to a ControlNet network

FOUNDATION Fieldbus 3125 KbpsControlNet 5 Mbps

2 16(8hellip10 recommended)

32

1757-FFLDC4 4 64

FactoryTalk View SERSFieldbusRSLogix 5000

1757-FFLD4

H1(1)

H1(2)H1(3)H1(4)

HSEIP

Publication 1756-SG001P-EN-P - May 2011 25

Example Configuration - Bridge to ControlNet Network

Other Connectivity Options

ControlLogix RedundancyFactoryTalk View SERSFieldbusRSLogix 5000

ControlNet Redundant Media

1757-FFLDC2

FF H1

EtherNetIP

Option Consideration

USB connection The 1756-L7x controller has a USB port in place of the serial port If your application requires RS-232 functionality see the many Encompass partners at httpwwwrockwellautomationcomencompass

Serial connection The serial port on the 1756-L6x controller is compatible with RS-232 serial communication The serial port supports the DF1 protocol to communicate with other devices on the serial linkTo use Logix5000 controllers on Modbus you connect through the serial port and execute a specific ladder logic routine The controller project is available with RSLogix 5000 Enterprise programming software For more information see Using Logix5000 Controllers as Masters or Slaves on Modbus Application Solution publication CIG-AP129

DH-485 network The controller serial port is compatible with DH-485 communication The DH-485 connection does support remote programming and monitoring via RSLogix 5000 softwareOr add a DH-485 communication bridge module (cat no 1756-DH485)

SynchLink network The SynchLink communication module (1756-SYNCH) provides time synchronization and data broadcasting capabilities for distributed motion and coordinated drive control The module connects a ControlLogix chassis to a SynchLink fiber-optic communication link

26 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Controllers The ControlLogix controller provides a scalable controller solution that is capable of addressing a large amount of IO points

The controller can be placed into any slot of a ControlLogix chassis and multiple controllers can be installed in the same chassis Multiple controllers in the same chassis communicate with each other over the backplane (just as controllers can communicate over networks) but operate independently

ControlLogix controllers can monitor and control IO across the ControlLogix backplane as well as over IO links ControlLogix controllers can communicate over EtherNetIP ControlNet DeviceNet DH+ Remote IO and RS-232-C (DF1DH-485 protocol) networks and many third party process and device networks To provide communication for a ControlLogix controller install the appropriate communication interface module into the chassis

For detailed specifications see 1756 ControlLogix Controllers Specifications publication 1756-TD001

Cat No Description User Memory

1756-L72 ControlLogix controller 1 built-in USB port 4 MB

1756-L73 8 MB

1756-L74 16 MB

1756-L75 32 MB

1756-L61 ControlLogix controller 1 built-in RS-232 port 2 MB

1756-L62 4 MB

1756-L63 8 MB

1756-L64 16 MB

1756-L65 32 MB

1756-L61S GuardLogix safety controller 2 MB standard1 MB safety

1756-L62S 4 MB standard1 MB safety

1756-L63S 8 MB standard375 MB safety

1756-LSP GuardLogix safety partner (one is required for each GuardLogix controller) mdash

1756-L63XT ControlLogix-XT controller extreme environment 8 MB

IMPORTANT Scan time for a project loaded in a 1756-L64 or 1756-L65 controller may be slower than for the same project loaded in one of the other 1756-L6x controllers See the Logix5000 Controllers Instruction Execution Time and Memory Use Reference Manual publication 1756-RM087 for instruction execution times

Publication 1756-SG001P-EN-P - May 2011 27

Standard ControlLogix Controllers

The ControlLogix controller is part of the Logix5000 family of controllers A ControlLogix system includes the following

The ControlLogix controller available in different combinations of user memory

RSLogix 5000 programming software 1756 ControlLogix IO modules that reside in a 1756 chassis Separate communication modules for network communication

Features - Standard ControlLogix Controllers

Feature 1756-L61 1756-L62 1756-L63 1756-L64 1756-L65

1756-L72 1756-L73 1756-L74 1756-L75

Controller tasks 32 tasks 100 programstask Event tasks all event triggers

Built-in communication ports 1 port RS-232 serial 1 port USB

Communication options EtherNetIP ControlNet DeviceNet Data Highway Plus Remote IO SynchLink Third-party process and device networks

Built-in port Serial USB

Controller connections supported max 250 500

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Full support

Integrated motion EtherNetIP connection SERCOS interface Analog options (encoder input LDT input SSI input)

Programming languages Relay ladder Structured text Function block SFC

28 Publication 1756-SG001P-EN-P - May 2011

GuardLogix Controllers

A GuardLogix controller is a ControlLogix controller that also provides safety control The GuardLogix system is a dual controller solutionmdashyou must use a 1756-L6xS primary controller and a 1756-LSP safety partner to achieve SIL 3CAT 4

During development safety and standard have the same rules multiple programmers online editing and forcing are all allowed Once the project is tested and ready for final validation you set the Safety Task to a SIL 3 integrity level which is then enforced by the GuardLogix controller When safety memory is locked and protected the safety logic cant be modified and all safety functions operate with SIL 3 integrity On the standard side of the GuardLogix controller all functions operate like a regular Logix controller

Use Guard IO modules for field device connectivity on Ethernet or DeviceNet networks and for safety interlocking between GuardLogix controllers use Ethernet or ControlNet networks Multiple GuardLogix controllers can share safety data for zone to zone interlocking or a single GuardLogix controller can use remote distributed safety IO between different cellsareas

In addition to the standard features of a ControlLogix controller the GuardLogix controller has these safety-related features

Application Description

SIL 1 2 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508 and applications up to and including PLeCat4 according to ISO 13849-1 For more information see GuardLogix Controllers Systems Safety Reference Manual publication 1756-RM093 GuardLogix Controllers User Manual publication 1756-UM020 GuardLogix Safety Application Instruction Set Reference Manual publication 1756-RM095

Features - GuardLogix Controllers

Feature 1756-L61S 1756-L62S 1756-L63S 1756-LSP

Safety communication options Standard and safety EtherNetIP ControlNet DeviceNet

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Not supported

Programming languages Relay ladder

Publication 1756-SG001P-EN-P - May 2011 29

ControlLogix-XT Controllers

The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh corrosive environments

When used with FLEX IO-XT products the ControlLogix-XT system can withstand temperatures range from -2070 C (-4158 F)

When used independently the ControlLogix-XT system can withstand temperature ranges from -2570 C (-13158 F)

Redundant ControlLogix Controllers

The ControlLogix controller supports controller redundancy In a redundant controller system you need these components

Two 1756 chassis each with the following the same ndash Number of slots

ndash Modules in the same slots

ndash Redundancy firmware revisions in each module

ndash Two additional ControlNet nodes outside the redundant chassis pair

You need one of these redundancy modules

One 1756-RM module per chassis that supports the followingndash Two 1756-L61 1756-L62 1761-L63 controllers or one 1756-L64

controller

ndash Maximum of seven communication modules which can be 1756-CN2 series B 1756-CN2R series B and 1756-EN2T modules

ndash One 1756-RMCx cable

One 1757-SRM module per chassis that supports the followingndash One 1756-L61 1756-L62 1756-L63 1756-L64 controller

ndash Maximum of seven communication modules which can be 1756-CNB series D or E 1756-CNBR series D or E 1756-ENBT and 1756-EWEB modules

ndash One 1757-SRCx cable

30 Publication 1756-SG001P-EN-P - May 2011

Accessories - Controllers

Memory Cards

Memory cards offer nonvolatile memory to permanently store a user program and tag data on a controller The 1756-L7x ControlLogix controller comes with 1784-SD1 Secure Digital (SD) card already installed The 1756-L6x controllers support optional CompactFlash cards that you purchase separately The memory card installs in a socket on the controller Through RSLogix 5000 software you can manually trigger the controller to save to or load from nonvolatile memory or configure the controller to load from nonvolatile memory on powerup

The GuardLogix controller does not support user program storage or retrieval by using a CompactFlash card

1756 Energy Storage Modules

Instead of a battery the 1756-L7x controller ships with a 1756-ESMCAP energy storage module (ESM) already installed

Attribute 1784-CF64 1784-CF128 1784-SD1 1784-SD2

Memory 64 MB 128 MB 1 GB 2 GB

Supported controllers 1756-L6x 1756-L7x

Weight approx 142 g (05 oz) 176 g (0062 oz)

Cat No Description

1756-ESMCAP Capacitor-based energy-storage module Comes with the controller

1756-EMNSE ESM without WallClockTime backup power Additionally you can use this ESM with a 1756-L73 (8 MB) or smaller memory-sized controller only

Use this ESM if your application requires that the installed ESM deplete its residual energy to 40 microJoule or less before transporting it into or out of your application

1756-ESMNRM Energy-storage module that secures the controller by preventing the USB connection and SD card useThis ESM provides your application an enhanced degree of security

Publication 1756-SG001P-EN-P - May 2011 31

1756 ControlLogix Batteries

Each 1756-L6x controller ships with a battery With a memory card installed the controller can be used without a battery If you do not use a battery current tag data will be at the state it was when the memory card was saved

ControlLogix Chassis The ControlLogix system is a modular system that requires a 1756 IO chassis Place any module into any slot The backplane provides a high-speed communication path between modules

All of the chassis are designed for horizontal-only back-panel mounting The chassis are available in these configurations

Standard chassis ControlLogix-XT chassis

For detailed specifications see 1756 ControlLogix Chassis Specifications Specifications publication 1756-TD006

Features - Chassis

Slot guides and snap-in retention for easy and secure module fit for any type of 1756 module

Direct mounting accommodates any 1756 power supply

Attribute 1756-BA1 1756-BA2 1756-BATM(1) 1756-BATA

Description Lithium battery (059 g) Lithium battery (059 g) Externally mounted battery assembly

Replacement lithium battery for 1756-BATM (5 g max lithium per each D cell contains 2 D cells)

ControlLogix controllers 1756-L61 1756-L62 1756-L63 series A

1756-L61 1756-L62 1756-L63 series B1756-L64 1756-L65

1756-L61 1756-L62 1756-L63 series A

1756-BATM battery module

GuardLogix controllers mdash 1756-L61S 1756-L62S 1756-L63S

mdash mdash

ControlLogix-XT controllers

mdash 1756-L63XT mdash mdash

(1) The 1756-BATM externally mounted battery assembly is highly recommended for use with all series A 1756-L6x controllers and provides longer battery life than the 1756-BA1 battery The 1756-BATM includes one 1756-BATA lithium battery assembly and a 1 m (328 ft) cable to connect housing to controller

32 Publication 1756-SG001P-EN-P - May 2011

Standard Chassis

The chassis backplane provides a high-speed communication path between modules and distributes power to each of the modules within the chassis

ControlLogix-XT Chassis

The ControlLogix-XT chassis support extreme temperature environments

Accessories - Chassis

Use a slot filler module to fill empty slots

Cat No Description Slots

1756-A4 ControlLogix standard chassis 4

1756-A7 7

1756-A10 10

1756-A13 13

1756-A17 17

Cat No Description Slots Temperature Range

1756-A4LXT ControlLogix-XT chassis 4 -2560 degC (-13140 degF)

1756-A5XT 5 -2570 degC (-13158 degF)

1756-A7LXT 7 -2560 degC (-13140 degF)

Cat No Description

1756-N2 Slot filler module for empty slots in standard ControlLogix chassis

1756-N2XT Slot filler module for empty slots in ControlLogix-XT chassis

Publication 1756-SG001P-EN-P - May 2011 33

ControlLogix Power Supplies

ControlLogix power supplies are used with the 1756 chassis to provide 12V 33V 5V and 24V DC power directly to the chassis backplane Select from these configurations

Standard power Redundant power ControlLogix-XT power

For detailed specifications see 1756 ControlLogix Power Supplies Specifications publication 1756-TD005

Standard Power Supplies

You mount a standard power supply directly on the left end of the chassis where it plugs directly into the backplane

ControlLogix-XT Power Supplies

The ControlLogix-XT power supplies support extreme temperature environments

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA72 ControlLogix standard AC 120V220V AC 85hellip265V AC Standard series A and series B

1756-PA75 120V220V AC 85hellip265V AC Standard series B

1756-PB72 ControlLogix standard DC 24V DC 18hellip32V DC Standard series A and series B

1756-PB75 24V DC 1832V DC Standard series B

1756-PC75 48V DC 30hellip60V DC Standard series B

1756-PH75 125V DC 90hellip143V DC Standard series B

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PAXT ControlLogix-XT AC power supply 85265V AC 120240V AC XT

1756-PBXT ControlLogix-XT DC power supply 24V DC 18hellip32V DC XT

34 Publication 1756-SG001P-EN-P - May 2011

Redundant Power Supplies

To build a redundant power supply system you need the following

Two redundant power supplies (both 1756-PA75R or 1756-PB75R) One 1756-PSCA2 chassis adapter module Two 1756-CPR2 cables to connect the power supplies to the

1756-PSCA2 chassis adapter module (091 m (3 ft) length) User-supplied annunciator wiring to connect the power supplies to the

input modules as needed

The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Accessories - Redundant Power Supplies

Visualization Products Visualization products together with Logix for control and NetLinx architecture for communication make up the Rockwell Automation Integrated Architecture strategy The visualization strategy combines Rockwell Automation expertise in Allen-Bradley electronic operator interface and industrialized personal computer hardware with Rockwell Software supervisory control software Current visualization products include the following

FactoryTalk View software PanelView Plus operator interface PanelView Plus CE operator interface Industrial computers and monitors

For more information see the Operator Interface catalog pages at httpwwwabcomenepubcatalogs1276221813761239781

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA75R ControlLogix redundant 120V220V AC 85hellip265V AC Standard series B

1756-PB75R 24V DC 192hellip32V DC Standard series B

Cat No Description Specifications

1756-PSCA2 Chassis adapter module Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Mounts directly to left side of 1756 chassis

1756-CPR2 Chassis adapter cable Connects redundant power supply to 1756-PCSA2 chassis adapter Length091 m (3 ft)

Publication 1756-SG001P-EN-P - May 2011 35

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB ltFEFF005500740069006c0069007a006500200065007300730061007300200063006f006e00660069006700750072006100e700f50065007300200064006500200066006f0072006d00610020006100200063007200690061007200200064006f00630075006d0065006e0074006f0073002000410064006f0062006500200050004400460020007000610072006100200069006d0070007200650073007300f5006500730020006400650020007100750061006c0069006400610064006500200065006d00200069006d00700072006500730073006f0072006100730020006400650073006b0074006f00700020006500200064006900730070006f00730069007400690076006f0073002000640065002000700072006f00760061002e0020004f007300200064006f00630075006d0065006e0074006f00730020005000440046002000630072006900610064006f007300200070006f00640065006d0020007300650072002000610062006500720074006f007300200063006f006d0020006f0020004100630072006f006200610074002000650020006f002000410064006f00620065002000520065006100640065007200200035002e0030002000650020007600650072007300f50065007300200070006f00730074006500720069006f007200650073002egt SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

ControlLogix-XT System

The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh corrosive environments

When used with FLEX IO-XT products the ControlLogix-XT system can withstand temperatures range from -2070 C (-4158 F)

When used independently the ControlLogix-XT system can withstand temperature ranges from -2570 C (-13158 F)

GuardLogix Safety System

A GuardLogix controller is a ControlLogix controller that also provides safety control The GuardLogix system is a dual controller solution mdash you must use a 1756-L6xS primary controller and a 1756-LSP safety partner to achieve SIL 3CAT 4 A major benefit of this system is that itrsquos still a single project safety and standard together The safety partner controller is a part of the system is automatically configured and requires no user setup

Application Description

SIL 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508 and applications up to and including category (CAT) 4 according to EN954-1 For more information see the following GuardLogix Controllers Systems Safety Reference Manual publication 1756-RM093 GuardLogix Controllers User Manual publication 1756-UM020 GuardLogix Safety Application Instruction Set Reference Manual publication 1756-RM095

SIL 2 Components of the ControlLogix system are type-approved and certified for use in SIL 2 applications according to IEC 61508 and AK4 applications according to DIN V19250 For a list of ControlLogix system components that meet SIL 2 requirements see Using ControlLogix in SIL 2 Applications Safety Reference Manual publication 1756-RM001

Publication 1756-SG001P-EN-P - May 2011 5

Example Configuration - Redundant ControlLogix System

The ControlLogix controller supports controller redundancy

OKAB

AB

DIAGNOSTIC

FLT

ST

FLT

ST

0 1 2 3 4 5 6 7

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

8 9 10 11 12 13 14 15

DC INTPUT

DIAGNOSTIC

FLT

ST

FLT

ST

0 1 2 3 4 5 6 7

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

8 9 10 11 12 13 14 15

DC OUTPUT

ST

ST

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

HART

ANALOG INPUT

OK

DIAGNOSTIC

FLT

ST

FLT

ST

0 1 2 3 4 5 6 7

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

8 9 10 11 12 13 14 15

DC INTPUT

DIAGNOSTIC

FLT

ST

FLT

ST

0 1 2 3 4 5 6 7

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

8 9 10 11 12 13 14 15

DC OUTPUT

ST

ST

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

HART

ANALOG INPUT

OK

POWER

OKAB

AB

OKCOMMPRI

REDUNDANCY MODULE

RUN IO

RS232

OK

FORCE

BAT

RUN REM PROG

Logix5564

RUN IO

RS232

OK

FORCE

BAT

RUN REM PROG

Logix5562

OKNETLINK

POWERPOWER

POWER

OKAB

AB

OKCOMMPRI

REDUNDANCY MODULE

RUN IO

RS232

OK

FORCE

BAT

RUN REM PROG

Logix5564

RUN IO

RS232

OK

FORCE

BAT

RUN REM PROG

Logix5562

OKNETLINK

ESC SEL

EOI or HMI

EtherNetIP or ControlNet

1756-RM

1756-EN2T

1756-CN2RB1756-RM

1756-L61 1756-L62 or 1756-L63

1756-EN2T

1756-CN2RB

Primary ControlLogix Chassis Secondary ControlLogix Chassis

Fiber Optic Cable

FLEX IO

1203-CN1

1336 Plus II AC Drive

1756-CNBR

1756-PA75R or 1756-PB75R Redundant Power Supplies Redundant ControlNet

ControlLogix IO1756-PSCA2 Chassis Adapter

1756-CPR2 Cables

1756-L61 1756-L62 or 1756-L63

6 Publication 1756-SG001P-EN-P - May 2011

Example Configuration - Redundant IO System

The 1715 redundant IO system lets a ControlLogix controller communicate to a remote redundant IO chassis over an EtherNetIP network The 1715 redundant IO system provides fault tolerance and redundancy for critical processes by using a redundant adapter pair and multiple IO modules that have diagnostics

The redundant IO system must be connected to a ControlLogix system via an EtherNetIP network All connections are established via the Ethernet network by using the topologies supported by the 1756-EN2TR communication bridge

For detailed specifications see the 1715 Redundant IO System Specifications Technical Data publication 1715-TD001A-EN-P

1756

-RM

1756

-EN

2TR

IO B

ASE

1715

-A31

0

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

IO B

ASE

1715

-A31

0

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

1715

-AEN

TR

1756

-EN

2TR

1756

-RM

1715

-AEN

TR

1715

-IO

1715

-IO

1715

-IO

1715

-IO

1715

-IO

1715

-IO

ControlLogix Primary Chassis ControlLogix Secondary Chassis

1715 Redundant IO System

Publication 1756-SG001P-EN-P - May 2011 7

ControlLogix IO Modules The ControlLogix architecture provides a wide range of input and output modules to span many applications from high-speed digital to process control The ControlLogix architecture uses a producerconsumer model so that input information and output status can be shared among multiple controllers

Each ControlLogix IO module mounts in a ControlLogix chassis and requires either a removable terminal block (RTB) or a 1492 interface module (IFM) to connect all field-side wiring RTBs and IFMs are not included with the IO modules They must be ordered separately

For detailed specifications see 1756 ControlLogix IO Modules Specifications publication 1756-TD002

AC Digital put Modules

AC Digital Output Modules

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

1756-IA8D 8 diagnostic inputs(4 pointsgroup)

120V AC 79hellip132V AC 1756-TBNH1756-TBSH

1756-IA16 16 inputs(8 pointsgroup)

120V AC 74hellip132V AC 1756-TBNH1756-TBSH

1756-IA16I 16 individually isolated inputs 120V AC 74hellip132V AC 1756-TBCH1756-TBS6H

1756-IA32 32 diagnostic inputs(4 pointsgroup)

120V AC 74hellip132V AC 1756-TBCH1756-TBS6H

1756-IM16I 16 individually isolated inputs 240V AC 159hellip265V AC 1756-TBCH1756-TBS6H

1756-IN16 16 inputs(8 pointsgroup)

24V AC 10hellip30V AC 1756-TBNH1756-TBSH

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

1756-OA8 8 outputs(4 pointsgroup)

120240V AC 79hellip265V AC 1756-TBNH1756-TBSH

1756-OA8D 8 diagnostic electronically fused outputs(4 pointsgroup)

120V AC 74hellip132V AC 1756-TBNH1756-TBSH

1756-OA8E 8 electronically fused outputs(4 pointsgroup)

120V AC 74hellip132V AC 1756-TBNH1756-TBSH

1756-OA16 16 mechanically fusedgroup outputs(8 pointsgroup)

120240V AC 74hellip265V AC 1756-TBNH1756-TBSH

1756-OA16I 16 individually isolated outputs

120240V AC 74hellip265V AC 1756-TBCH1756-TBS6H

1756-ON8 8 outputs(4 pointsgroup)

24V AC 10hellip30V AC current gt50 mA16hellip30V AC current lt50 mA

1756-TBNH1756-TBSH

8 Publication 1756-SG001P-EN-P - May 2011

DC Digital Input Modules

DC Digital Output Modules

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

1756-IB16 16 inputs(8 pointsgroup)

1224V DC sink 10312V DC 1756-TBNH1756-TBSH

1756-IB16D 16 diagnostic inputs(4 pointsgroup)

1224V DC sink 1030V DC 1756-TBCH1756-TBS6H

1756-IB16I 16 individually isolated inputs 1224V DC sinksource 1030V DC 1756-TBCH1756-TBS6H

1756-IB16ISOE 16 individually isolated sequence of events inputs

2448V DC sinksource 1055V DC 1756-TBCH1756-TBS6H

1756-IB32 32 inputs(16 pointsgroup)

1224V DC sink 10312V DC 1756-TBCH1756-TBS6H

1756-IC16 16 inputs(8 pointsgroup)

48V DC sink 3055V DC 60 degC (140 degC)3060V DC 55 degC (131 degC)

1756-TBNH1756-TBSH

1756-IG16 16 inputs(8 pointsgroup)

5V DC TTL source (Low=True)

4555V DC 1756-TBNH1756-TBSH

1756-IH16I 16 individually isolated inputs 125V DC sinksource 90146V DC 1756-TBCH1756-TBS6H

1756-IH16ISOE 16 individually isolated sequence of events inputs

125V DC sinksource 90140V DC 1756-TBCH1756-TBS6H

1756-IV16 16 inputs(8 pointsgroup)

1224V DC source 1030V DC 1756-TBNH1756-TBSH

1756-IV32 32 inputs(16 pointsgroup)

1224V DC source 1030V DC 1756-TBCH1756-TBS6H

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

1756-OB8 8 outputs 1224V DC source 1030V DC 1756-TBNH1756-TBSH

1756-OB8EI 8 electronically fused individually isolated outputs

1224V DC source 1030V DC 1756-TBCH1756-TBS6H

1756-OB8I 8 individually isolated outputs 1224V DC source 1030V DC 1756-TBCH1756-TBS6H

1756-OB16D 16 diagnostic outputs(8 pointsgroup)

24V DC source 19230V DC 1756-TBCH1756-TBS6H

1756-OB16E 16 electronically fused outputs(8 pointsgroup)

1224V DC source 10312V DC 1756-TBNH1756-TBSH

1756-OB16I 16 individually isolated outputs

1224V DC sinksource 1030V DC 1756-TBCH1756-TBS6H

1756-OB16IS 16 individually isolated outputs8 scheduled outputs

1224V DC sinksource 1030V DC 1756-TBCH1756-TBS6H

1756-OB32 32 outputs(16 pointsgroup)

1224V DC source 10312V DC 1756-TBCH1756-TBS6H

Publication 1756-SG001P-EN-P - May 2011 9

Contact Output Modules

Analog Input Modules

1756-OC8 8 outputs(4 pointsgroup)

48V DC source 3060V DC 1756-TBNH1756-TBSH

1756-OG16 16 (8 pointsgroup) 5V DC TTL source (Low=True)

4555V DC 1756-TBNH1756-TBSH

1756-OH8I 8 outputsindividually isolated

120V DC 90146V DC 1756-TBCH1756-TBS6H

1756-OV16E 16 electronically fused outputs(8 pointsgroup)

1224V DC sink 1030V DC 1756-TBNH1756-TBSH

1756-OV32E 32 electronically fused outputs (16 pointsgroup)

1224V DC sink 1030V DC 1756-TBCH1756-TBS6H

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

Cat No InputsOutputs Operating Voltage Range Removable Terminal Block

1756-OW16I 16 normally open individually isolated outputs 5150V DC10265V AC

1756-TBCH1756-TBS6H

1756-OX8I 8 normally open8 normally closed individually isolated outputs(2 pointsgroup)

5150V DC10265V AC

1756-TBCH1756-TBS6H

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-IF6CIS 6 individually isolated inputs current sourcing

0hellip21 mA 16 bits034 Abit

1756-TBNH1756-TBSH

1756-IF6I 6 individually isolated inputs plusmn105V0hellip105V0hellip525V0hellip21 mA

16 bits105V 343 Vbit0hellip105V 171 Vbit0hellip525V 86 Vbit0hellip21 mA 034 Abit

1756-TBNH1756-TBSH

1756-IF8 8 single-ended inputs4 differential inputs2 high-speed differential inputs

plusmn1025V01025V05125V0hellip205 mA

plusmn1025V 320 Vcnt (15 bits plus sign bipolar)0hellip1025V 160 Vcnt (16 bits)0hellip5125V 80 V cnt (16 bits)0hellip205mA 032 Acnt (16 bits)

1756-TBCH1756-TBS6H

10 Publication 1756-SG001P-EN-P - May 2011

Analog RTD and Thermocouple Modules

Analog Output Modules

1756-IF8H 8 differential voltage or current inputs HART interface

plusmn10V05V1hellip5V010V0hellip20 mA4hellip20 mA

16hellip21 bits 1756-TBCH1756-TBS6H

1756-IF16 16 single-ended inputs8 differential or 4 differential (high speed) inputs

plusmn105V0hellip105V0hellip525V0hellip21 mA

16 bits105V 343 Vbit0hellip105V 171 Vbit0hellip525V 86 Vbit0hellip21 mA 034 Abit

1756-TBCH1756-TBS6H

1756-IF16H 16 differential current inputs HART interface

0hellip20 mA4hellip20 mA

16hellip21 bits 1756-TBCH1756-TBS6H

Cat No InputsOutputs Range Resolution Removable Terminal Block

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-IR6I 6 individually isolated RTD inputs 1hellip487 2hellip1000 4hellip20008hellip4020

16 bits1hellip487 77 mbit2hellip1000 15 mbit4hellip2000 30 mbit8hellip4020 60 mbit

1756-TBNH1756-TBSH

1756-IT6I 6 individually isolated thermocouple inputs1 CJC

-12hellip78 mV-12hellip30 mV

16 bits-1278 mV 14 Vbit-1230 mV 07 Vbit

1756-TBNH1756-TBSH

1756-IT6I2 6 individually isolated thermocouple inputs2 CJC

-12hellip78 mV (14 V per bit)-12hellip30 mV (07 V per bit ndash high resolution range)

16 bits-1278 mV 14 Vbit-1230 mV 07 Vbit

1756-TBNH1756-TBSH

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-OF4 4 voltage or current outputs plusmn104V0hellip21 mA

Voltage15 bits across 105V 320 VbitCurrent15 bits across 21mA 650 nAbit

1756-TBNH1756-TBSH

1756-OF6CI 6 individually isolated outputs current

0hellip21 mA 13 bits across 21 mA (27 A) 1756-TBNH1756-TBSH

1756-OF6VI 6 individually isolated outputs voltage

plusmn105V 14 bits across 21V (13 mV)(13 bits across 105V +sign bit)

1756-TBNH1756-TBSH

1756-OF8 8 voltage or current outputs plusmn104V0hellip21 mA

15 bits across 21 mA - 650 nAbit15 bits across 104V - 320 Vbit

1756-TBNH1756-TBSH

1756-OF8H 8 voltage or current outputs HART interface

plusmn104V0hellip20 mA4hellip20 mA

15hellip16 bits 1756-TBNH1756-TBSH

Publication 1756-SG001P-EN-P - May 2011 11

Analog Combination Input and Output Module

Specialty IO Modules

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-IF4FXOF2F 4 high-speed sub-millisecond differential inputs2 high-speed voltage or current outputs

Inputplusmn105V0hellip105V0hellip525V0hellip21 mAOutputplusmn104V0hellip21 mA

InputApprox 14 bits across plusmn10V DC (21V total)plusmn10V 13 mVbit 14-bit effective0hellip105V 13 mVbit 13-bit effective0hellip525V 13 mVbit 12-bit effectiveApprox 12 bits across 21 mA0hellip21 mA 525 AbitOutput13 bits across 21 mA = 28 Abit14 bits across 218V = 13 mVbit

1756-TBCH1756-TBS6H

Cat No InputsOutputs Description Removable Terminal Block

1756-CFM 4 inputs (2 per channel) 2 outputs current sourcing

Configurable flowmeter module2 Flowmeter (F) inputs used for all modes2 Gate inputs used in Totalizer mode for proverstore count

1756-TBNH1756-TBSH

1756-HSC 2 counters each with 3 inputs (A B Z for gatereset)4 outputs (2 pointsgroup)

High-speed counter module5V operation 45hellip55V DC1224V operation 10hellip312V DC

1756-TBCH1756-TBS6H

1756-PLS Left section 2 groups of 4 outputs and 4 inputs eachCenter section resolver interface and IO controlRight section 2 groups of 4 outputs and 4 inputs each

Programmable limit switch module Requires 3 RTBs 1756-TBNH or 1756-TBSH

12 Publication 1756-SG001P-EN-P - May 2011

HART Smart Instrumentation

HART (Highway Addressable Remote Transmitter) is an open protocol designed to connect analog devices For HART connectivity select from products available from Rockwell Automation and our Encompass partners

Typical HART Configuration

HART Interfaces

Accessories - IO Modules

1756 Removable Terminal Blocks

Removable terminal blocks (RTBs) provide a flexible interconnection between your plant wiring and 1756 IO modules The RTB plugs into the front of the IO module The type of module determines which RTB you need You can choose screw-clamp or spring-clamp RTBs

RTBs are not shipped with IO modules You must order them separately The standard housing on the front of the wiring arm is not deep enough for 25 mm2

HART Devices

ControlLogix Controller with 1756-IF8H or 1756-OF8H module

If your application has Select Description

Analog and HART connectivity in one moduleNo external hardware required to access HART signalHART commands can be transmitted as unscheduled messagesSupports asset management software to HART device

1756-IF8H1756-IF16H1756-OF8H

Rockwell Automation analog IO modules

Data acquisition or control application with slow update requirements (such as a tank farm)No external hardware required to access HART signalDoes not connect directly to asset management software

MVI56-HART Prosoft interface

Analog and HART in one moduleInstrumentation in hazardous locations (FLEX Ex modules)HART commands can be transmitted as unscheduled messagesDirectly connects asset management software to HART devices

1794 FLEX IO1797 FLEX Ex IO

There are specific FLEX IO and FLEX Ex modules designed for HART systems These catalog numbers end in an H such as 1797-IE8H

Publication 1756-SG001P-EN-P - May 2011 13

(14 AWG) wiring If you plan to use 25 mm2 (14 AWG) wiring also order the extended housing

Wiring Systems

As an alternative to buying RTBs and connecting the wires yourself you can buy a wiring system of the following

Interface modules (IFMs) that provide the output terminal blocks for digital IO modules Use the pre-wired cables that match the IO module to the IFM

Analog interface modules (AIFMs) that provide the output terminal blocks for analog IO modules Use the pre-wired cables that match the IO module to the AIFM

IO module-ready cables One end of the cable assembly is an RTB that plugs into the front of the IO module The other end has individually color-coded conductors that connect to a standard terminal block

Attribute 1756-TBNH 1756-TBSH 1756-TBCH 1756-TBS6H 1756-TBE

Description 20-position NEMA screw-clamp removable block

20-pin spring-clamp removable terminal block with standard housing

36-pin cage-clamp removable terminal block with standard housing

36-pin spring-clamp removable terminal block with standard housing

Extended depth terminal block housing

Screw torque 08hellip1 Nbullm7hellip9 lbbullin

04 Nbullm44 lbbullin

mdash

Screwdriver width 8 mm (516 in) max

IO Module

RTBPre-wired Cable

Factory-wired

Interface Module (IFM)

Field Wiring

14 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Integrated Motion

The Logix architecture supports motion control components that work in a wide variety of machine architectures

Integrated motion on EtherNetIP supports a connection to Ethernet drives

The Kinetix integrated-motion solution uses a SERCOS interface module to perform multi-axis synchronized motion

Logix integrated motion supports the analog family of servo modules for controlling drivesactuators

Networked motion provides the ability to connect via the DeviceNet network to a single axis drive to perform point-to-point indexing

For detailed specifications on motion interface modules see 1756 ControlLogix Integrated Motion Specifications publication 1756-TD004

For more information see these publications

Motion Analyzer CD to size your motion application and to make final component selection Download the software from httpwwwabcommotionsoftwareanalyzerhtml

Kinetix Motion Control Selection Guide publication GMC-SG001 to verify drive motor and accessory specifications

Integrated Motion on an EtherNetIP Network

Product Consideration

Drive that supports EtherNetIP connections Unlimited velocity torque and Vhz configured drives Kinetix 6500 drives PowerFlex 755 drives

ControlLogix controller As many as 100 drives per controller

ControlLogix EtherNetIP communication module 1hellip8 position configured drives with 1756-EN2TR module 1hellip255 position configured drives with 1756-EN3TR module

Publication 1756-SG001P-EN-P - May 2011 15

SERCOS Interface Modules

The SERCOS interface modules can connect to these servo drives

2093 Kinetix 2000 multi-axis servo drive 2094 Kinetix 6000 multi-axis servo drive 2099 Kinetix 7000 high-power servo drive 2098 Ultra3000 SERCOS servo drive

ControlLogix Controller

PanelView Plus Terminal

Workstations

POINT IO ModulesDrive with EtherNetIP Connection

Cat No Description Number of Axis

1756-M16SE Rockwell Automation SERCOS interface modules 16

1756-M08SE 8

1756-M03SE 3

1756-M08SEG SERCOS interface drives that are Extended Pack Profile compliant 8

16 Publication 1756-SG001P-EN-P - May 2011

Analog Motion Interface Modules

RSLogix 5000 Software1756-MxxSE Module

ControlLogix Controller

Three-phase Input Power

Line Interface Module

Integrated Axis Module

Motor Motor Feedback

Axis Modules

Slot Filler Module

Shunt Module

SERCOS Fiber-optic RingKinetix 6000 Multi-axis Servo Drive

Cat No Description Number of Axis

1756-M02AE Analog servo interface drives with quadrature feedback 2

1756-HYD02 Analog hydraulic servo interface drives LDT feedback 2

1756-M02AS Analog servo interface drives with SSI feedback 2

Publication 1756-SG001P-EN-P - May 2011 17

ControlLogix Communication Modules

Separate communication modules are available for different networks Install multiple communication modules into the ControlLogix backplane to bridge or route control and information data between different networks You can route a message through a maximum of four chassis (eight communication hops) You do not need a ControlLogix controller in the chassis

For detailed specifications see 1756 ControlLogix Network Specifications publication 1756-TD003

Application Network Page

Plant management (material handling) Configuration data collection and control on a single high-speed network Time-critical applications with no established schedule Inclusion of commercial technologies (such as video over IP) InternetIntranet connection Integrated CIP motion and safety

EtherNetIP network 19

High-speed transfer of time-critical data between controllers and IO devices Deterministic and repeatable data delivery Media redundancy Intrinsic safety Redundant controller systems

ControlNet network 20

Connections of low-level devices directly to plant floor controllers without interfacing them through IO modules

Data sent as needed More diagnostics for improved data collection and fault detection Less wiring and reduced start-up time than a traditional hard-wired system

DeviceNet network 21

Plant-wide and cell-level data sharing with program maintenance Data sent regularly Transfer of information between controllers

Data Highway Plus network 23

Connections between controllers and IO adapters Data sent regularly Distributed control so that each controller has its own IO and communicates with a

supervisory controller

Remote IO network 23

Fieldbus transmitters and actuators Closed-loop control Process automation

Foundation Fieldbus network 25

18 Publication 1756-SG001P-EN-P - May 2011

EtherNetIP Communication Modules

The Ethernet Industrial (EtherNetIP) network protocol is an open industrial-networking standard that supports both real-time IO messaging and message exchange The EtherNetIP network uses off-the-shelf Ethernet communication chips and physical media

Accessories - EtherNetIP Network

Cat No Description Media Communication Rate

CIP Motion Axes max

TCPIP Connections

Logix Connections

1756-EN2F EtherNetIP bridge fiber Fiber 100 Mbps 8 128 256

1756-EN2T EtherNetIP bridge copper Copper 10100 Mbps 8 128 256

1756-EN2TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 8 128 256

1756-EN3TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 255 128 256

1756-ENBT EtherNetIP bridge copper Copper 10100 Mbps mdash 64 128

1756-EWEB Ethernet web server module Copper 10100 Mbps mdash 64 128

1756-EN2TXT ControlLogix-XT extended temperature EtherNetIP bridge copper for extreme environments

Copper 10100 Mbps 8 128 256

Cat No Description Specifications

1585J-M8PBJM-x Ethernet RJ45 patchcordx = 2 (2 m) 5 (5 m) or 10 (10 m)

8-conductor Teal Riser PVC Cable (Flex Rated cable also available)

1585J-M8CC-H RJ45 insulation displacement connector (IDC) 01280325 mm2 (26hellip22 AWG) Cat 6 IDC no tool required

1585J-M8CC-C RJ45 crimp connector with boot qty = 50 pieces 01280205 mm2 (26hellip24 AWG Cat 5e requires crimp tool for assembly

1585A-Jcrimp Crimp tool mdash

9300-RADES Remote access dial-in kit 56 Kbps modem connection to devices on an Ethernet network includes pre-configured modem communication module DIN rail mounting hardware associated cables

Publication 1756-SG001P-EN-P - May 2011 19

Example Configuration - EtherNetIP Network

ControlNet Communication ModulesThe ControlNet network combines the functionality of an IO network and a peer-to-peer network providing high-speed performance The ControlNet network provides deterministic repeatable transfers of critical control data

FirewallRouter

Stratix Switch

Stratix Switch

Stratix Switch

Powermonitor 3000PowerFlex 70

Ethernet PLC-5

MicroLogix

Ethernet SLC 500

1756 IO

1794 IO

1761-NET-ENI

ControlNet

DeviceNet

1734 IO

RSLinxPanelView Plus

1769-L35E CompactLogix

Cat No Description Communication Rate

Logix Connections Number of Nodes

1756-CN2B ControlNet bridge standard media 5 Mbps 128(1) 99

1756-CN2RB ControlNet bridge redundant media 5 Mbps 128(1) 99

1756-CNB ControlNet bridge standard media 5 Mbps 64(2) 99

1756-CNBR ControlNet bridge redundant media 5 Mbps 64(2) 99

1756-CN2RXT ControlLogix-XT extended temperature ControlNet bridge redundant media

5 Mbps 128(1) 99

(1) 128 connections are available for standard use An additional three connections are reserved for redundant control

(2) Recommend using only 4048 Logix connections for IO

20 Publication 1756-SG001P-EN-P - May 2011

Example Configuration - ControlNet Network

Example Configuration - Redundant ControlNet Media

For information on ControlNet media see ControlNet Media System Components List AG-PA002

DeviceNet Communication Module

The DeviceNet network provides connections between simple industrial devices (such as sensors and actuators) and higher-level devices (such as controllers and computers)

1784-U2CNPanelView Plus

1788-CN2DN

DeviceNetPowerFlex 700SPLC-540CControlLogix

Redundant Media

ControlLogix1756-CNBR

ControlNet Node

ControlNet Node

Cat No Description Communication Rate Number of Nodes

1756-DNB DeviceNet bridge 125 Kbps (500 m max)250 Kbps (250 m max)500 Kbps (100 m max)

64

Publication 1756-SG001P-EN-P - May 2011 21

Example Configuration - DeviceNet Network

Accessories - DeviceNet Network

PLC-51771-SDN ControlLogix

1756-DNB

Ultra3000

PanelView Plus1784-U2DN

Ultra5000

IO

Motor starter

PowerFlex AC

Sensor Pushbuttons

LightsBar Code Scanner

Cat No Description

KwikLink Lite flat media KwikLink Lite flat media is a newer ODVA-approved solution for wiring DeviceNet networks Drop-lines for connecting nodes are added by using the KwikLink Lite two-piece connectors This cable system supports the intermixing of DeviceNet cable types (thin-round with flat) All of the KwikLink Lite connectors provide insulation displacement technology with reduced assembly time

KwikLink flat media The KwikLink flat media system provides a modular cabling method with its flat 4-wire cable and insulation displacement connectors (IDCs) The KwikLink system allows nodes to be added to the network without severing the trunkline Cutting or stripping of the trunkline is eliminated as is the need for predetermined cable lengths

Round media Round trunk cable is available in bulk spools or as pre-molded cordsets or patchcords in varying lengths A wide variety of rugged durable DeviceNet components is available for use in round trunk systems Stainless steel versions of round cable system components are also available Thick-trunk round media systems use thick cable for maximum DeviceNet trunk line length Round media thin-trunk systems use thin cable to reduce maximum trunk line distances with a more

compact and cost-effective installation for some applications Thin-cable outer jacket material is TPE for additional chemical resistance

22 Publication 1756-SG001P-EN-P - May 2011

Data Highway Plus and Remote IO Communication Modules

The Data Highway Plus network supports messaging between devices The remote IO link connects to remote IO chassis and other intelligent devices

The 1756-DHRIO module supports messaging between devices on DH+ networks The remote IO functionality enables the module to act as a scanner for transferring digital and block-transfer data to and from remote IO devices

The 1756-RIO module can act as a scanner or adapter on a remote IO network In addition to digital and block-transfer data the 1756-RIO module transfers analog and specialty data without message instructions

Cat No Description Communication Rate DH+ Connections RIO Connections Maximum Recommended Logix Connections

1756-DHRIO Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

1756-RIO Remote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

mdash Remote IO scanner or adapter32 physical racks (076) any combination of rack size and block transfers

10 scheduled IO

1756-DHRIOXT ControlLogix-XT extended temperature Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

Publication 1756-SG001P-EN-P - May 2011 23

Example Configuration - DH+ Network

Example Configuration - Remote IO Network

Accessories - DH+ and Remote IO Networks

PanelView Plus

PLC-5 1784-U2DHPRSLogix 5000

ControlLogix1756-DHRIO

SLC 504

PanelView PlusPLC-5

1791 IO1794 IO

1756-RIO as a Remote IO Adapter

1756-DHRIO as a Remote IO Scanner

Cat No Description Specifications

1770-CD Cable to connect communication module to DH+ network Belden 9463 twinaxial

9300-RADKIT Remote access dial-in kit 56 Kbps modem connection to devices on a DH+ network includes pre-configured modem communication module DIN rail mounting hardware associated cables

24 Publication 1756-SG001P-EN-P - May 2011

FOUNDATION Fieldbus Linking Devices

The FOUNDATION Fieldbus protocol is a network designed for distributed control of process applications

Example Configuration - Bridge to EtherNetIP Network

Cat No Description Communication Rate Number of H1 Ports

Devices per H1 Link

Devices per Linking Device

1757FFLD2 FOUNDATION Fieldbus bridge to an Ethernet network

FOUNDATION Fieldbus 3125 KbpsEtherNetIP 10100 Mbps

2 16(8hellip10 recommended)

32

1757-FFLD4 4 64

1757-FFLDC2 FOUNDATION Fieldbus bridge to a ControlNet network

FOUNDATION Fieldbus 3125 KbpsControlNet 5 Mbps

2 16(8hellip10 recommended)

32

1757-FFLDC4 4 64

FactoryTalk View SERSFieldbusRSLogix 5000

1757-FFLD4

H1(1)

H1(2)H1(3)H1(4)

HSEIP

Publication 1756-SG001P-EN-P - May 2011 25

Example Configuration - Bridge to ControlNet Network

Other Connectivity Options

ControlLogix RedundancyFactoryTalk View SERSFieldbusRSLogix 5000

ControlNet Redundant Media

1757-FFLDC2

FF H1

EtherNetIP

Option Consideration

USB connection The 1756-L7x controller has a USB port in place of the serial port If your application requires RS-232 functionality see the many Encompass partners at httpwwwrockwellautomationcomencompass

Serial connection The serial port on the 1756-L6x controller is compatible with RS-232 serial communication The serial port supports the DF1 protocol to communicate with other devices on the serial linkTo use Logix5000 controllers on Modbus you connect through the serial port and execute a specific ladder logic routine The controller project is available with RSLogix 5000 Enterprise programming software For more information see Using Logix5000 Controllers as Masters or Slaves on Modbus Application Solution publication CIG-AP129

DH-485 network The controller serial port is compatible with DH-485 communication The DH-485 connection does support remote programming and monitoring via RSLogix 5000 softwareOr add a DH-485 communication bridge module (cat no 1756-DH485)

SynchLink network The SynchLink communication module (1756-SYNCH) provides time synchronization and data broadcasting capabilities for distributed motion and coordinated drive control The module connects a ControlLogix chassis to a SynchLink fiber-optic communication link

26 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Controllers The ControlLogix controller provides a scalable controller solution that is capable of addressing a large amount of IO points

The controller can be placed into any slot of a ControlLogix chassis and multiple controllers can be installed in the same chassis Multiple controllers in the same chassis communicate with each other over the backplane (just as controllers can communicate over networks) but operate independently

ControlLogix controllers can monitor and control IO across the ControlLogix backplane as well as over IO links ControlLogix controllers can communicate over EtherNetIP ControlNet DeviceNet DH+ Remote IO and RS-232-C (DF1DH-485 protocol) networks and many third party process and device networks To provide communication for a ControlLogix controller install the appropriate communication interface module into the chassis

For detailed specifications see 1756 ControlLogix Controllers Specifications publication 1756-TD001

Cat No Description User Memory

1756-L72 ControlLogix controller 1 built-in USB port 4 MB

1756-L73 8 MB

1756-L74 16 MB

1756-L75 32 MB

1756-L61 ControlLogix controller 1 built-in RS-232 port 2 MB

1756-L62 4 MB

1756-L63 8 MB

1756-L64 16 MB

1756-L65 32 MB

1756-L61S GuardLogix safety controller 2 MB standard1 MB safety

1756-L62S 4 MB standard1 MB safety

1756-L63S 8 MB standard375 MB safety

1756-LSP GuardLogix safety partner (one is required for each GuardLogix controller) mdash

1756-L63XT ControlLogix-XT controller extreme environment 8 MB

IMPORTANT Scan time for a project loaded in a 1756-L64 or 1756-L65 controller may be slower than for the same project loaded in one of the other 1756-L6x controllers See the Logix5000 Controllers Instruction Execution Time and Memory Use Reference Manual publication 1756-RM087 for instruction execution times

Publication 1756-SG001P-EN-P - May 2011 27

Standard ControlLogix Controllers

The ControlLogix controller is part of the Logix5000 family of controllers A ControlLogix system includes the following

The ControlLogix controller available in different combinations of user memory

RSLogix 5000 programming software 1756 ControlLogix IO modules that reside in a 1756 chassis Separate communication modules for network communication

Features - Standard ControlLogix Controllers

Feature 1756-L61 1756-L62 1756-L63 1756-L64 1756-L65

1756-L72 1756-L73 1756-L74 1756-L75

Controller tasks 32 tasks 100 programstask Event tasks all event triggers

Built-in communication ports 1 port RS-232 serial 1 port USB

Communication options EtherNetIP ControlNet DeviceNet Data Highway Plus Remote IO SynchLink Third-party process and device networks

Built-in port Serial USB

Controller connections supported max 250 500

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Full support

Integrated motion EtherNetIP connection SERCOS interface Analog options (encoder input LDT input SSI input)

Programming languages Relay ladder Structured text Function block SFC

28 Publication 1756-SG001P-EN-P - May 2011

GuardLogix Controllers

A GuardLogix controller is a ControlLogix controller that also provides safety control The GuardLogix system is a dual controller solutionmdashyou must use a 1756-L6xS primary controller and a 1756-LSP safety partner to achieve SIL 3CAT 4

During development safety and standard have the same rules multiple programmers online editing and forcing are all allowed Once the project is tested and ready for final validation you set the Safety Task to a SIL 3 integrity level which is then enforced by the GuardLogix controller When safety memory is locked and protected the safety logic cant be modified and all safety functions operate with SIL 3 integrity On the standard side of the GuardLogix controller all functions operate like a regular Logix controller

Use Guard IO modules for field device connectivity on Ethernet or DeviceNet networks and for safety interlocking between GuardLogix controllers use Ethernet or ControlNet networks Multiple GuardLogix controllers can share safety data for zone to zone interlocking or a single GuardLogix controller can use remote distributed safety IO between different cellsareas

In addition to the standard features of a ControlLogix controller the GuardLogix controller has these safety-related features

Application Description

SIL 1 2 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508 and applications up to and including PLeCat4 according to ISO 13849-1 For more information see GuardLogix Controllers Systems Safety Reference Manual publication 1756-RM093 GuardLogix Controllers User Manual publication 1756-UM020 GuardLogix Safety Application Instruction Set Reference Manual publication 1756-RM095

Features - GuardLogix Controllers

Feature 1756-L61S 1756-L62S 1756-L63S 1756-LSP

Safety communication options Standard and safety EtherNetIP ControlNet DeviceNet

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Not supported

Programming languages Relay ladder

Publication 1756-SG001P-EN-P - May 2011 29

ControlLogix-XT Controllers

The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh corrosive environments

When used with FLEX IO-XT products the ControlLogix-XT system can withstand temperatures range from -2070 C (-4158 F)

When used independently the ControlLogix-XT system can withstand temperature ranges from -2570 C (-13158 F)

Redundant ControlLogix Controllers

The ControlLogix controller supports controller redundancy In a redundant controller system you need these components

Two 1756 chassis each with the following the same ndash Number of slots

ndash Modules in the same slots

ndash Redundancy firmware revisions in each module

ndash Two additional ControlNet nodes outside the redundant chassis pair

You need one of these redundancy modules

One 1756-RM module per chassis that supports the followingndash Two 1756-L61 1756-L62 1761-L63 controllers or one 1756-L64

controller

ndash Maximum of seven communication modules which can be 1756-CN2 series B 1756-CN2R series B and 1756-EN2T modules

ndash One 1756-RMCx cable

One 1757-SRM module per chassis that supports the followingndash One 1756-L61 1756-L62 1756-L63 1756-L64 controller

ndash Maximum of seven communication modules which can be 1756-CNB series D or E 1756-CNBR series D or E 1756-ENBT and 1756-EWEB modules

ndash One 1757-SRCx cable

30 Publication 1756-SG001P-EN-P - May 2011

Accessories - Controllers

Memory Cards

Memory cards offer nonvolatile memory to permanently store a user program and tag data on a controller The 1756-L7x ControlLogix controller comes with 1784-SD1 Secure Digital (SD) card already installed The 1756-L6x controllers support optional CompactFlash cards that you purchase separately The memory card installs in a socket on the controller Through RSLogix 5000 software you can manually trigger the controller to save to or load from nonvolatile memory or configure the controller to load from nonvolatile memory on powerup

The GuardLogix controller does not support user program storage or retrieval by using a CompactFlash card

1756 Energy Storage Modules

Instead of a battery the 1756-L7x controller ships with a 1756-ESMCAP energy storage module (ESM) already installed

Attribute 1784-CF64 1784-CF128 1784-SD1 1784-SD2

Memory 64 MB 128 MB 1 GB 2 GB

Supported controllers 1756-L6x 1756-L7x

Weight approx 142 g (05 oz) 176 g (0062 oz)

Cat No Description

1756-ESMCAP Capacitor-based energy-storage module Comes with the controller

1756-EMNSE ESM without WallClockTime backup power Additionally you can use this ESM with a 1756-L73 (8 MB) or smaller memory-sized controller only

Use this ESM if your application requires that the installed ESM deplete its residual energy to 40 microJoule or less before transporting it into or out of your application

1756-ESMNRM Energy-storage module that secures the controller by preventing the USB connection and SD card useThis ESM provides your application an enhanced degree of security

Publication 1756-SG001P-EN-P - May 2011 31

1756 ControlLogix Batteries

Each 1756-L6x controller ships with a battery With a memory card installed the controller can be used without a battery If you do not use a battery current tag data will be at the state it was when the memory card was saved

ControlLogix Chassis The ControlLogix system is a modular system that requires a 1756 IO chassis Place any module into any slot The backplane provides a high-speed communication path between modules

All of the chassis are designed for horizontal-only back-panel mounting The chassis are available in these configurations

Standard chassis ControlLogix-XT chassis

For detailed specifications see 1756 ControlLogix Chassis Specifications Specifications publication 1756-TD006

Features - Chassis

Slot guides and snap-in retention for easy and secure module fit for any type of 1756 module

Direct mounting accommodates any 1756 power supply

Attribute 1756-BA1 1756-BA2 1756-BATM(1) 1756-BATA

Description Lithium battery (059 g) Lithium battery (059 g) Externally mounted battery assembly

Replacement lithium battery for 1756-BATM (5 g max lithium per each D cell contains 2 D cells)

ControlLogix controllers 1756-L61 1756-L62 1756-L63 series A

1756-L61 1756-L62 1756-L63 series B1756-L64 1756-L65

1756-L61 1756-L62 1756-L63 series A

1756-BATM battery module

GuardLogix controllers mdash 1756-L61S 1756-L62S 1756-L63S

mdash mdash

ControlLogix-XT controllers

mdash 1756-L63XT mdash mdash

(1) The 1756-BATM externally mounted battery assembly is highly recommended for use with all series A 1756-L6x controllers and provides longer battery life than the 1756-BA1 battery The 1756-BATM includes one 1756-BATA lithium battery assembly and a 1 m (328 ft) cable to connect housing to controller

32 Publication 1756-SG001P-EN-P - May 2011

Standard Chassis

The chassis backplane provides a high-speed communication path between modules and distributes power to each of the modules within the chassis

ControlLogix-XT Chassis

The ControlLogix-XT chassis support extreme temperature environments

Accessories - Chassis

Use a slot filler module to fill empty slots

Cat No Description Slots

1756-A4 ControlLogix standard chassis 4

1756-A7 7

1756-A10 10

1756-A13 13

1756-A17 17

Cat No Description Slots Temperature Range

1756-A4LXT ControlLogix-XT chassis 4 -2560 degC (-13140 degF)

1756-A5XT 5 -2570 degC (-13158 degF)

1756-A7LXT 7 -2560 degC (-13140 degF)

Cat No Description

1756-N2 Slot filler module for empty slots in standard ControlLogix chassis

1756-N2XT Slot filler module for empty slots in ControlLogix-XT chassis

Publication 1756-SG001P-EN-P - May 2011 33

ControlLogix Power Supplies

ControlLogix power supplies are used with the 1756 chassis to provide 12V 33V 5V and 24V DC power directly to the chassis backplane Select from these configurations

Standard power Redundant power ControlLogix-XT power

For detailed specifications see 1756 ControlLogix Power Supplies Specifications publication 1756-TD005

Standard Power Supplies

You mount a standard power supply directly on the left end of the chassis where it plugs directly into the backplane

ControlLogix-XT Power Supplies

The ControlLogix-XT power supplies support extreme temperature environments

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA72 ControlLogix standard AC 120V220V AC 85hellip265V AC Standard series A and series B

1756-PA75 120V220V AC 85hellip265V AC Standard series B

1756-PB72 ControlLogix standard DC 24V DC 18hellip32V DC Standard series A and series B

1756-PB75 24V DC 1832V DC Standard series B

1756-PC75 48V DC 30hellip60V DC Standard series B

1756-PH75 125V DC 90hellip143V DC Standard series B

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PAXT ControlLogix-XT AC power supply 85265V AC 120240V AC XT

1756-PBXT ControlLogix-XT DC power supply 24V DC 18hellip32V DC XT

34 Publication 1756-SG001P-EN-P - May 2011

Redundant Power Supplies

To build a redundant power supply system you need the following

Two redundant power supplies (both 1756-PA75R or 1756-PB75R) One 1756-PSCA2 chassis adapter module Two 1756-CPR2 cables to connect the power supplies to the

1756-PSCA2 chassis adapter module (091 m (3 ft) length) User-supplied annunciator wiring to connect the power supplies to the

input modules as needed

The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Accessories - Redundant Power Supplies

Visualization Products Visualization products together with Logix for control and NetLinx architecture for communication make up the Rockwell Automation Integrated Architecture strategy The visualization strategy combines Rockwell Automation expertise in Allen-Bradley electronic operator interface and industrialized personal computer hardware with Rockwell Software supervisory control software Current visualization products include the following

FactoryTalk View software PanelView Plus operator interface PanelView Plus CE operator interface Industrial computers and monitors

For more information see the Operator Interface catalog pages at httpwwwabcomenepubcatalogs1276221813761239781

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA75R ControlLogix redundant 120V220V AC 85hellip265V AC Standard series B

1756-PB75R 24V DC 192hellip32V DC Standard series B

Cat No Description Specifications

1756-PSCA2 Chassis adapter module Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Mounts directly to left side of 1756 chassis

1756-CPR2 Chassis adapter cable Connects redundant power supply to 1756-PCSA2 chassis adapter Length091 m (3 ft)

Publication 1756-SG001P-EN-P - May 2011 35

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN ltFEFF9ad854c18cea51fa529b7528002000410064006f0062006500200050004400460020658766f8306e4f5c6210306b4f7f75283057307e30593002537052376642306e753b8cea3092670059279650306b4fdd306430533068304c3067304d307e3059300230c730b930af30c830c330d730d730ea30f330bf3067306e53705237307e305f306f30d730eb30fc30d57528306b9069305730663044307e305930023053306e8a2d5b9a30674f5c62103055308c305f0020005000440046002030d530a130a430eb306f3001004100630072006f0062006100740020304a30883073002000410064006f00620065002000520065006100640065007200200035002e003000204ee5964d3067958b304f30533068304c3067304d307e30593002gt KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE ltFEFF0041006e007600e4006e00640020006400650020006800e4007200200069006e0073007400e4006c006c006e0069006e006700610072006e00610020006f006d002000640075002000760069006c006c00200073006b006100700061002000410064006f006200650020005000440046002d0064006f006b0075006d0065006e00740020006600f600720020006b00760061006c00690074006500740073007500740073006b0072006900660074006500720020007000e5002000760061006e006c00690067006100200073006b0072006900760061007200650020006f006300680020006600f600720020006b006f007200720065006b007400750072002e002000200053006b006100700061006400650020005000440046002d0064006f006b0075006d0065006e00740020006b0061006e002000f600700070006e00610073002000690020004100630072006f0062006100740020006f00630068002000410064006f00620065002000520065006100640065007200200035002e00300020006f00630068002000730065006e006100720065002egt ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

Example Configuration - Redundant ControlLogix System

The ControlLogix controller supports controller redundancy

OKAB

AB

DIAGNOSTIC

FLT

ST

FLT

ST

0 1 2 3 4 5 6 7

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

8 9 10 11 12 13 14 15

DC INTPUT

DIAGNOSTIC

FLT

ST

FLT

ST

0 1 2 3 4 5 6 7

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

8 9 10 11 12 13 14 15

DC OUTPUT

ST

ST

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

HART

ANALOG INPUT

OK

DIAGNOSTIC

FLT

ST

FLT

ST

0 1 2 3 4 5 6 7

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

8 9 10 11 12 13 14 15

DC INTPUT

DIAGNOSTIC

FLT

ST

FLT

ST

0 1 2 3 4 5 6 7

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

8 9 10 11 12 13 14 15

DC OUTPUT

ST

ST

0 1 2 3 4 5 6 7

8 9 10 11 12 13 14 15

HART

ANALOG INPUT

OK

POWER

OKAB

AB

OKCOMMPRI

REDUNDANCY MODULE

RUN IO

RS232

OK

FORCE

BAT

RUN REM PROG

Logix5564

RUN IO

RS232

OK

FORCE

BAT

RUN REM PROG

Logix5562

OKNETLINK

POWERPOWER

POWER

OKAB

AB

OKCOMMPRI

REDUNDANCY MODULE

RUN IO

RS232

OK

FORCE

BAT

RUN REM PROG

Logix5564

RUN IO

RS232

OK

FORCE

BAT

RUN REM PROG

Logix5562

OKNETLINK

ESC SEL

EOI or HMI

EtherNetIP or ControlNet

1756-RM

1756-EN2T

1756-CN2RB1756-RM

1756-L61 1756-L62 or 1756-L63

1756-EN2T

1756-CN2RB

Primary ControlLogix Chassis Secondary ControlLogix Chassis

Fiber Optic Cable

FLEX IO

1203-CN1

1336 Plus II AC Drive

1756-CNBR

1756-PA75R or 1756-PB75R Redundant Power Supplies Redundant ControlNet

ControlLogix IO1756-PSCA2 Chassis Adapter

1756-CPR2 Cables

1756-L61 1756-L62 or 1756-L63

6 Publication 1756-SG001P-EN-P - May 2011

Example Configuration - Redundant IO System

The 1715 redundant IO system lets a ControlLogix controller communicate to a remote redundant IO chassis over an EtherNetIP network The 1715 redundant IO system provides fault tolerance and redundancy for critical processes by using a redundant adapter pair and multiple IO modules that have diagnostics

The redundant IO system must be connected to a ControlLogix system via an EtherNetIP network All connections are established via the Ethernet network by using the topologies supported by the 1756-EN2TR communication bridge

For detailed specifications see the 1715 Redundant IO System Specifications Technical Data publication 1715-TD001A-EN-P

1756

-RM

1756

-EN

2TR

IO B

ASE

1715

-A31

0

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

IO B

ASE

1715

-A31

0

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

1715

-AEN

TR

1756

-EN

2TR

1756

-RM

1715

-AEN

TR

1715

-IO

1715

-IO

1715

-IO

1715

-IO

1715

-IO

1715

-IO

ControlLogix Primary Chassis ControlLogix Secondary Chassis

1715 Redundant IO System

Publication 1756-SG001P-EN-P - May 2011 7

ControlLogix IO Modules The ControlLogix architecture provides a wide range of input and output modules to span many applications from high-speed digital to process control The ControlLogix architecture uses a producerconsumer model so that input information and output status can be shared among multiple controllers

Each ControlLogix IO module mounts in a ControlLogix chassis and requires either a removable terminal block (RTB) or a 1492 interface module (IFM) to connect all field-side wiring RTBs and IFMs are not included with the IO modules They must be ordered separately

For detailed specifications see 1756 ControlLogix IO Modules Specifications publication 1756-TD002

AC Digital put Modules

AC Digital Output Modules

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

1756-IA8D 8 diagnostic inputs(4 pointsgroup)

120V AC 79hellip132V AC 1756-TBNH1756-TBSH

1756-IA16 16 inputs(8 pointsgroup)

120V AC 74hellip132V AC 1756-TBNH1756-TBSH

1756-IA16I 16 individually isolated inputs 120V AC 74hellip132V AC 1756-TBCH1756-TBS6H

1756-IA32 32 diagnostic inputs(4 pointsgroup)

120V AC 74hellip132V AC 1756-TBCH1756-TBS6H

1756-IM16I 16 individually isolated inputs 240V AC 159hellip265V AC 1756-TBCH1756-TBS6H

1756-IN16 16 inputs(8 pointsgroup)

24V AC 10hellip30V AC 1756-TBNH1756-TBSH

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

1756-OA8 8 outputs(4 pointsgroup)

120240V AC 79hellip265V AC 1756-TBNH1756-TBSH

1756-OA8D 8 diagnostic electronically fused outputs(4 pointsgroup)

120V AC 74hellip132V AC 1756-TBNH1756-TBSH

1756-OA8E 8 electronically fused outputs(4 pointsgroup)

120V AC 74hellip132V AC 1756-TBNH1756-TBSH

1756-OA16 16 mechanically fusedgroup outputs(8 pointsgroup)

120240V AC 74hellip265V AC 1756-TBNH1756-TBSH

1756-OA16I 16 individually isolated outputs

120240V AC 74hellip265V AC 1756-TBCH1756-TBS6H

1756-ON8 8 outputs(4 pointsgroup)

24V AC 10hellip30V AC current gt50 mA16hellip30V AC current lt50 mA

1756-TBNH1756-TBSH

8 Publication 1756-SG001P-EN-P - May 2011

DC Digital Input Modules

DC Digital Output Modules

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

1756-IB16 16 inputs(8 pointsgroup)

1224V DC sink 10312V DC 1756-TBNH1756-TBSH

1756-IB16D 16 diagnostic inputs(4 pointsgroup)

1224V DC sink 1030V DC 1756-TBCH1756-TBS6H

1756-IB16I 16 individually isolated inputs 1224V DC sinksource 1030V DC 1756-TBCH1756-TBS6H

1756-IB16ISOE 16 individually isolated sequence of events inputs

2448V DC sinksource 1055V DC 1756-TBCH1756-TBS6H

1756-IB32 32 inputs(16 pointsgroup)

1224V DC sink 10312V DC 1756-TBCH1756-TBS6H

1756-IC16 16 inputs(8 pointsgroup)

48V DC sink 3055V DC 60 degC (140 degC)3060V DC 55 degC (131 degC)

1756-TBNH1756-TBSH

1756-IG16 16 inputs(8 pointsgroup)

5V DC TTL source (Low=True)

4555V DC 1756-TBNH1756-TBSH

1756-IH16I 16 individually isolated inputs 125V DC sinksource 90146V DC 1756-TBCH1756-TBS6H

1756-IH16ISOE 16 individually isolated sequence of events inputs

125V DC sinksource 90140V DC 1756-TBCH1756-TBS6H

1756-IV16 16 inputs(8 pointsgroup)

1224V DC source 1030V DC 1756-TBNH1756-TBSH

1756-IV32 32 inputs(16 pointsgroup)

1224V DC source 1030V DC 1756-TBCH1756-TBS6H

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

1756-OB8 8 outputs 1224V DC source 1030V DC 1756-TBNH1756-TBSH

1756-OB8EI 8 electronically fused individually isolated outputs

1224V DC source 1030V DC 1756-TBCH1756-TBS6H

1756-OB8I 8 individually isolated outputs 1224V DC source 1030V DC 1756-TBCH1756-TBS6H

1756-OB16D 16 diagnostic outputs(8 pointsgroup)

24V DC source 19230V DC 1756-TBCH1756-TBS6H

1756-OB16E 16 electronically fused outputs(8 pointsgroup)

1224V DC source 10312V DC 1756-TBNH1756-TBSH

1756-OB16I 16 individually isolated outputs

1224V DC sinksource 1030V DC 1756-TBCH1756-TBS6H

1756-OB16IS 16 individually isolated outputs8 scheduled outputs

1224V DC sinksource 1030V DC 1756-TBCH1756-TBS6H

1756-OB32 32 outputs(16 pointsgroup)

1224V DC source 10312V DC 1756-TBCH1756-TBS6H

Publication 1756-SG001P-EN-P - May 2011 9

Contact Output Modules

Analog Input Modules

1756-OC8 8 outputs(4 pointsgroup)

48V DC source 3060V DC 1756-TBNH1756-TBSH

1756-OG16 16 (8 pointsgroup) 5V DC TTL source (Low=True)

4555V DC 1756-TBNH1756-TBSH

1756-OH8I 8 outputsindividually isolated

120V DC 90146V DC 1756-TBCH1756-TBS6H

1756-OV16E 16 electronically fused outputs(8 pointsgroup)

1224V DC sink 1030V DC 1756-TBNH1756-TBSH

1756-OV32E 32 electronically fused outputs (16 pointsgroup)

1224V DC sink 1030V DC 1756-TBCH1756-TBS6H

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

Cat No InputsOutputs Operating Voltage Range Removable Terminal Block

1756-OW16I 16 normally open individually isolated outputs 5150V DC10265V AC

1756-TBCH1756-TBS6H

1756-OX8I 8 normally open8 normally closed individually isolated outputs(2 pointsgroup)

5150V DC10265V AC

1756-TBCH1756-TBS6H

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-IF6CIS 6 individually isolated inputs current sourcing

0hellip21 mA 16 bits034 Abit

1756-TBNH1756-TBSH

1756-IF6I 6 individually isolated inputs plusmn105V0hellip105V0hellip525V0hellip21 mA

16 bits105V 343 Vbit0hellip105V 171 Vbit0hellip525V 86 Vbit0hellip21 mA 034 Abit

1756-TBNH1756-TBSH

1756-IF8 8 single-ended inputs4 differential inputs2 high-speed differential inputs

plusmn1025V01025V05125V0hellip205 mA

plusmn1025V 320 Vcnt (15 bits plus sign bipolar)0hellip1025V 160 Vcnt (16 bits)0hellip5125V 80 V cnt (16 bits)0hellip205mA 032 Acnt (16 bits)

1756-TBCH1756-TBS6H

10 Publication 1756-SG001P-EN-P - May 2011

Analog RTD and Thermocouple Modules

Analog Output Modules

1756-IF8H 8 differential voltage or current inputs HART interface

plusmn10V05V1hellip5V010V0hellip20 mA4hellip20 mA

16hellip21 bits 1756-TBCH1756-TBS6H

1756-IF16 16 single-ended inputs8 differential or 4 differential (high speed) inputs

plusmn105V0hellip105V0hellip525V0hellip21 mA

16 bits105V 343 Vbit0hellip105V 171 Vbit0hellip525V 86 Vbit0hellip21 mA 034 Abit

1756-TBCH1756-TBS6H

1756-IF16H 16 differential current inputs HART interface

0hellip20 mA4hellip20 mA

16hellip21 bits 1756-TBCH1756-TBS6H

Cat No InputsOutputs Range Resolution Removable Terminal Block

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-IR6I 6 individually isolated RTD inputs 1hellip487 2hellip1000 4hellip20008hellip4020

16 bits1hellip487 77 mbit2hellip1000 15 mbit4hellip2000 30 mbit8hellip4020 60 mbit

1756-TBNH1756-TBSH

1756-IT6I 6 individually isolated thermocouple inputs1 CJC

-12hellip78 mV-12hellip30 mV

16 bits-1278 mV 14 Vbit-1230 mV 07 Vbit

1756-TBNH1756-TBSH

1756-IT6I2 6 individually isolated thermocouple inputs2 CJC

-12hellip78 mV (14 V per bit)-12hellip30 mV (07 V per bit ndash high resolution range)

16 bits-1278 mV 14 Vbit-1230 mV 07 Vbit

1756-TBNH1756-TBSH

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-OF4 4 voltage or current outputs plusmn104V0hellip21 mA

Voltage15 bits across 105V 320 VbitCurrent15 bits across 21mA 650 nAbit

1756-TBNH1756-TBSH

1756-OF6CI 6 individually isolated outputs current

0hellip21 mA 13 bits across 21 mA (27 A) 1756-TBNH1756-TBSH

1756-OF6VI 6 individually isolated outputs voltage

plusmn105V 14 bits across 21V (13 mV)(13 bits across 105V +sign bit)

1756-TBNH1756-TBSH

1756-OF8 8 voltage or current outputs plusmn104V0hellip21 mA

15 bits across 21 mA - 650 nAbit15 bits across 104V - 320 Vbit

1756-TBNH1756-TBSH

1756-OF8H 8 voltage or current outputs HART interface

plusmn104V0hellip20 mA4hellip20 mA

15hellip16 bits 1756-TBNH1756-TBSH

Publication 1756-SG001P-EN-P - May 2011 11

Analog Combination Input and Output Module

Specialty IO Modules

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-IF4FXOF2F 4 high-speed sub-millisecond differential inputs2 high-speed voltage or current outputs

Inputplusmn105V0hellip105V0hellip525V0hellip21 mAOutputplusmn104V0hellip21 mA

InputApprox 14 bits across plusmn10V DC (21V total)plusmn10V 13 mVbit 14-bit effective0hellip105V 13 mVbit 13-bit effective0hellip525V 13 mVbit 12-bit effectiveApprox 12 bits across 21 mA0hellip21 mA 525 AbitOutput13 bits across 21 mA = 28 Abit14 bits across 218V = 13 mVbit

1756-TBCH1756-TBS6H

Cat No InputsOutputs Description Removable Terminal Block

1756-CFM 4 inputs (2 per channel) 2 outputs current sourcing

Configurable flowmeter module2 Flowmeter (F) inputs used for all modes2 Gate inputs used in Totalizer mode for proverstore count

1756-TBNH1756-TBSH

1756-HSC 2 counters each with 3 inputs (A B Z for gatereset)4 outputs (2 pointsgroup)

High-speed counter module5V operation 45hellip55V DC1224V operation 10hellip312V DC

1756-TBCH1756-TBS6H

1756-PLS Left section 2 groups of 4 outputs and 4 inputs eachCenter section resolver interface and IO controlRight section 2 groups of 4 outputs and 4 inputs each

Programmable limit switch module Requires 3 RTBs 1756-TBNH or 1756-TBSH

12 Publication 1756-SG001P-EN-P - May 2011

HART Smart Instrumentation

HART (Highway Addressable Remote Transmitter) is an open protocol designed to connect analog devices For HART connectivity select from products available from Rockwell Automation and our Encompass partners

Typical HART Configuration

HART Interfaces

Accessories - IO Modules

1756 Removable Terminal Blocks

Removable terminal blocks (RTBs) provide a flexible interconnection between your plant wiring and 1756 IO modules The RTB plugs into the front of the IO module The type of module determines which RTB you need You can choose screw-clamp or spring-clamp RTBs

RTBs are not shipped with IO modules You must order them separately The standard housing on the front of the wiring arm is not deep enough for 25 mm2

HART Devices

ControlLogix Controller with 1756-IF8H or 1756-OF8H module

If your application has Select Description

Analog and HART connectivity in one moduleNo external hardware required to access HART signalHART commands can be transmitted as unscheduled messagesSupports asset management software to HART device

1756-IF8H1756-IF16H1756-OF8H

Rockwell Automation analog IO modules

Data acquisition or control application with slow update requirements (such as a tank farm)No external hardware required to access HART signalDoes not connect directly to asset management software

MVI56-HART Prosoft interface

Analog and HART in one moduleInstrumentation in hazardous locations (FLEX Ex modules)HART commands can be transmitted as unscheduled messagesDirectly connects asset management software to HART devices

1794 FLEX IO1797 FLEX Ex IO

There are specific FLEX IO and FLEX Ex modules designed for HART systems These catalog numbers end in an H such as 1797-IE8H

Publication 1756-SG001P-EN-P - May 2011 13

(14 AWG) wiring If you plan to use 25 mm2 (14 AWG) wiring also order the extended housing

Wiring Systems

As an alternative to buying RTBs and connecting the wires yourself you can buy a wiring system of the following

Interface modules (IFMs) that provide the output terminal blocks for digital IO modules Use the pre-wired cables that match the IO module to the IFM

Analog interface modules (AIFMs) that provide the output terminal blocks for analog IO modules Use the pre-wired cables that match the IO module to the AIFM

IO module-ready cables One end of the cable assembly is an RTB that plugs into the front of the IO module The other end has individually color-coded conductors that connect to a standard terminal block

Attribute 1756-TBNH 1756-TBSH 1756-TBCH 1756-TBS6H 1756-TBE

Description 20-position NEMA screw-clamp removable block

20-pin spring-clamp removable terminal block with standard housing

36-pin cage-clamp removable terminal block with standard housing

36-pin spring-clamp removable terminal block with standard housing

Extended depth terminal block housing

Screw torque 08hellip1 Nbullm7hellip9 lbbullin

04 Nbullm44 lbbullin

mdash

Screwdriver width 8 mm (516 in) max

IO Module

RTBPre-wired Cable

Factory-wired

Interface Module (IFM)

Field Wiring

14 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Integrated Motion

The Logix architecture supports motion control components that work in a wide variety of machine architectures

Integrated motion on EtherNetIP supports a connection to Ethernet drives

The Kinetix integrated-motion solution uses a SERCOS interface module to perform multi-axis synchronized motion

Logix integrated motion supports the analog family of servo modules for controlling drivesactuators

Networked motion provides the ability to connect via the DeviceNet network to a single axis drive to perform point-to-point indexing

For detailed specifications on motion interface modules see 1756 ControlLogix Integrated Motion Specifications publication 1756-TD004

For more information see these publications

Motion Analyzer CD to size your motion application and to make final component selection Download the software from httpwwwabcommotionsoftwareanalyzerhtml

Kinetix Motion Control Selection Guide publication GMC-SG001 to verify drive motor and accessory specifications

Integrated Motion on an EtherNetIP Network

Product Consideration

Drive that supports EtherNetIP connections Unlimited velocity torque and Vhz configured drives Kinetix 6500 drives PowerFlex 755 drives

ControlLogix controller As many as 100 drives per controller

ControlLogix EtherNetIP communication module 1hellip8 position configured drives with 1756-EN2TR module 1hellip255 position configured drives with 1756-EN3TR module

Publication 1756-SG001P-EN-P - May 2011 15

SERCOS Interface Modules

The SERCOS interface modules can connect to these servo drives

2093 Kinetix 2000 multi-axis servo drive 2094 Kinetix 6000 multi-axis servo drive 2099 Kinetix 7000 high-power servo drive 2098 Ultra3000 SERCOS servo drive

ControlLogix Controller

PanelView Plus Terminal

Workstations

POINT IO ModulesDrive with EtherNetIP Connection

Cat No Description Number of Axis

1756-M16SE Rockwell Automation SERCOS interface modules 16

1756-M08SE 8

1756-M03SE 3

1756-M08SEG SERCOS interface drives that are Extended Pack Profile compliant 8

16 Publication 1756-SG001P-EN-P - May 2011

Analog Motion Interface Modules

RSLogix 5000 Software1756-MxxSE Module

ControlLogix Controller

Three-phase Input Power

Line Interface Module

Integrated Axis Module

Motor Motor Feedback

Axis Modules

Slot Filler Module

Shunt Module

SERCOS Fiber-optic RingKinetix 6000 Multi-axis Servo Drive

Cat No Description Number of Axis

1756-M02AE Analog servo interface drives with quadrature feedback 2

1756-HYD02 Analog hydraulic servo interface drives LDT feedback 2

1756-M02AS Analog servo interface drives with SSI feedback 2

Publication 1756-SG001P-EN-P - May 2011 17

ControlLogix Communication Modules

Separate communication modules are available for different networks Install multiple communication modules into the ControlLogix backplane to bridge or route control and information data between different networks You can route a message through a maximum of four chassis (eight communication hops) You do not need a ControlLogix controller in the chassis

For detailed specifications see 1756 ControlLogix Network Specifications publication 1756-TD003

Application Network Page

Plant management (material handling) Configuration data collection and control on a single high-speed network Time-critical applications with no established schedule Inclusion of commercial technologies (such as video over IP) InternetIntranet connection Integrated CIP motion and safety

EtherNetIP network 19

High-speed transfer of time-critical data between controllers and IO devices Deterministic and repeatable data delivery Media redundancy Intrinsic safety Redundant controller systems

ControlNet network 20

Connections of low-level devices directly to plant floor controllers without interfacing them through IO modules

Data sent as needed More diagnostics for improved data collection and fault detection Less wiring and reduced start-up time than a traditional hard-wired system

DeviceNet network 21

Plant-wide and cell-level data sharing with program maintenance Data sent regularly Transfer of information between controllers

Data Highway Plus network 23

Connections between controllers and IO adapters Data sent regularly Distributed control so that each controller has its own IO and communicates with a

supervisory controller

Remote IO network 23

Fieldbus transmitters and actuators Closed-loop control Process automation

Foundation Fieldbus network 25

18 Publication 1756-SG001P-EN-P - May 2011

EtherNetIP Communication Modules

The Ethernet Industrial (EtherNetIP) network protocol is an open industrial-networking standard that supports both real-time IO messaging and message exchange The EtherNetIP network uses off-the-shelf Ethernet communication chips and physical media

Accessories - EtherNetIP Network

Cat No Description Media Communication Rate

CIP Motion Axes max

TCPIP Connections

Logix Connections

1756-EN2F EtherNetIP bridge fiber Fiber 100 Mbps 8 128 256

1756-EN2T EtherNetIP bridge copper Copper 10100 Mbps 8 128 256

1756-EN2TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 8 128 256

1756-EN3TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 255 128 256

1756-ENBT EtherNetIP bridge copper Copper 10100 Mbps mdash 64 128

1756-EWEB Ethernet web server module Copper 10100 Mbps mdash 64 128

1756-EN2TXT ControlLogix-XT extended temperature EtherNetIP bridge copper for extreme environments

Copper 10100 Mbps 8 128 256

Cat No Description Specifications

1585J-M8PBJM-x Ethernet RJ45 patchcordx = 2 (2 m) 5 (5 m) or 10 (10 m)

8-conductor Teal Riser PVC Cable (Flex Rated cable also available)

1585J-M8CC-H RJ45 insulation displacement connector (IDC) 01280325 mm2 (26hellip22 AWG) Cat 6 IDC no tool required

1585J-M8CC-C RJ45 crimp connector with boot qty = 50 pieces 01280205 mm2 (26hellip24 AWG Cat 5e requires crimp tool for assembly

1585A-Jcrimp Crimp tool mdash

9300-RADES Remote access dial-in kit 56 Kbps modem connection to devices on an Ethernet network includes pre-configured modem communication module DIN rail mounting hardware associated cables

Publication 1756-SG001P-EN-P - May 2011 19

Example Configuration - EtherNetIP Network

ControlNet Communication ModulesThe ControlNet network combines the functionality of an IO network and a peer-to-peer network providing high-speed performance The ControlNet network provides deterministic repeatable transfers of critical control data

FirewallRouter

Stratix Switch

Stratix Switch

Stratix Switch

Powermonitor 3000PowerFlex 70

Ethernet PLC-5

MicroLogix

Ethernet SLC 500

1756 IO

1794 IO

1761-NET-ENI

ControlNet

DeviceNet

1734 IO

RSLinxPanelView Plus

1769-L35E CompactLogix

Cat No Description Communication Rate

Logix Connections Number of Nodes

1756-CN2B ControlNet bridge standard media 5 Mbps 128(1) 99

1756-CN2RB ControlNet bridge redundant media 5 Mbps 128(1) 99

1756-CNB ControlNet bridge standard media 5 Mbps 64(2) 99

1756-CNBR ControlNet bridge redundant media 5 Mbps 64(2) 99

1756-CN2RXT ControlLogix-XT extended temperature ControlNet bridge redundant media

5 Mbps 128(1) 99

(1) 128 connections are available for standard use An additional three connections are reserved for redundant control

(2) Recommend using only 4048 Logix connections for IO

20 Publication 1756-SG001P-EN-P - May 2011

Example Configuration - ControlNet Network

Example Configuration - Redundant ControlNet Media

For information on ControlNet media see ControlNet Media System Components List AG-PA002

DeviceNet Communication Module

The DeviceNet network provides connections between simple industrial devices (such as sensors and actuators) and higher-level devices (such as controllers and computers)

1784-U2CNPanelView Plus

1788-CN2DN

DeviceNetPowerFlex 700SPLC-540CControlLogix

Redundant Media

ControlLogix1756-CNBR

ControlNet Node

ControlNet Node

Cat No Description Communication Rate Number of Nodes

1756-DNB DeviceNet bridge 125 Kbps (500 m max)250 Kbps (250 m max)500 Kbps (100 m max)

64

Publication 1756-SG001P-EN-P - May 2011 21

Example Configuration - DeviceNet Network

Accessories - DeviceNet Network

PLC-51771-SDN ControlLogix

1756-DNB

Ultra3000

PanelView Plus1784-U2DN

Ultra5000

IO

Motor starter

PowerFlex AC

Sensor Pushbuttons

LightsBar Code Scanner

Cat No Description

KwikLink Lite flat media KwikLink Lite flat media is a newer ODVA-approved solution for wiring DeviceNet networks Drop-lines for connecting nodes are added by using the KwikLink Lite two-piece connectors This cable system supports the intermixing of DeviceNet cable types (thin-round with flat) All of the KwikLink Lite connectors provide insulation displacement technology with reduced assembly time

KwikLink flat media The KwikLink flat media system provides a modular cabling method with its flat 4-wire cable and insulation displacement connectors (IDCs) The KwikLink system allows nodes to be added to the network without severing the trunkline Cutting or stripping of the trunkline is eliminated as is the need for predetermined cable lengths

Round media Round trunk cable is available in bulk spools or as pre-molded cordsets or patchcords in varying lengths A wide variety of rugged durable DeviceNet components is available for use in round trunk systems Stainless steel versions of round cable system components are also available Thick-trunk round media systems use thick cable for maximum DeviceNet trunk line length Round media thin-trunk systems use thin cable to reduce maximum trunk line distances with a more

compact and cost-effective installation for some applications Thin-cable outer jacket material is TPE for additional chemical resistance

22 Publication 1756-SG001P-EN-P - May 2011

Data Highway Plus and Remote IO Communication Modules

The Data Highway Plus network supports messaging between devices The remote IO link connects to remote IO chassis and other intelligent devices

The 1756-DHRIO module supports messaging between devices on DH+ networks The remote IO functionality enables the module to act as a scanner for transferring digital and block-transfer data to and from remote IO devices

The 1756-RIO module can act as a scanner or adapter on a remote IO network In addition to digital and block-transfer data the 1756-RIO module transfers analog and specialty data without message instructions

Cat No Description Communication Rate DH+ Connections RIO Connections Maximum Recommended Logix Connections

1756-DHRIO Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

1756-RIO Remote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

mdash Remote IO scanner or adapter32 physical racks (076) any combination of rack size and block transfers

10 scheduled IO

1756-DHRIOXT ControlLogix-XT extended temperature Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

Publication 1756-SG001P-EN-P - May 2011 23

Example Configuration - DH+ Network

Example Configuration - Remote IO Network

Accessories - DH+ and Remote IO Networks

PanelView Plus

PLC-5 1784-U2DHPRSLogix 5000

ControlLogix1756-DHRIO

SLC 504

PanelView PlusPLC-5

1791 IO1794 IO

1756-RIO as a Remote IO Adapter

1756-DHRIO as a Remote IO Scanner

Cat No Description Specifications

1770-CD Cable to connect communication module to DH+ network Belden 9463 twinaxial

9300-RADKIT Remote access dial-in kit 56 Kbps modem connection to devices on a DH+ network includes pre-configured modem communication module DIN rail mounting hardware associated cables

24 Publication 1756-SG001P-EN-P - May 2011

FOUNDATION Fieldbus Linking Devices

The FOUNDATION Fieldbus protocol is a network designed for distributed control of process applications

Example Configuration - Bridge to EtherNetIP Network

Cat No Description Communication Rate Number of H1 Ports

Devices per H1 Link

Devices per Linking Device

1757FFLD2 FOUNDATION Fieldbus bridge to an Ethernet network

FOUNDATION Fieldbus 3125 KbpsEtherNetIP 10100 Mbps

2 16(8hellip10 recommended)

32

1757-FFLD4 4 64

1757-FFLDC2 FOUNDATION Fieldbus bridge to a ControlNet network

FOUNDATION Fieldbus 3125 KbpsControlNet 5 Mbps

2 16(8hellip10 recommended)

32

1757-FFLDC4 4 64

FactoryTalk View SERSFieldbusRSLogix 5000

1757-FFLD4

H1(1)

H1(2)H1(3)H1(4)

HSEIP

Publication 1756-SG001P-EN-P - May 2011 25

Example Configuration - Bridge to ControlNet Network

Other Connectivity Options

ControlLogix RedundancyFactoryTalk View SERSFieldbusRSLogix 5000

ControlNet Redundant Media

1757-FFLDC2

FF H1

EtherNetIP

Option Consideration

USB connection The 1756-L7x controller has a USB port in place of the serial port If your application requires RS-232 functionality see the many Encompass partners at httpwwwrockwellautomationcomencompass

Serial connection The serial port on the 1756-L6x controller is compatible with RS-232 serial communication The serial port supports the DF1 protocol to communicate with other devices on the serial linkTo use Logix5000 controllers on Modbus you connect through the serial port and execute a specific ladder logic routine The controller project is available with RSLogix 5000 Enterprise programming software For more information see Using Logix5000 Controllers as Masters or Slaves on Modbus Application Solution publication CIG-AP129

DH-485 network The controller serial port is compatible with DH-485 communication The DH-485 connection does support remote programming and monitoring via RSLogix 5000 softwareOr add a DH-485 communication bridge module (cat no 1756-DH485)

SynchLink network The SynchLink communication module (1756-SYNCH) provides time synchronization and data broadcasting capabilities for distributed motion and coordinated drive control The module connects a ControlLogix chassis to a SynchLink fiber-optic communication link

26 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Controllers The ControlLogix controller provides a scalable controller solution that is capable of addressing a large amount of IO points

The controller can be placed into any slot of a ControlLogix chassis and multiple controllers can be installed in the same chassis Multiple controllers in the same chassis communicate with each other over the backplane (just as controllers can communicate over networks) but operate independently

ControlLogix controllers can monitor and control IO across the ControlLogix backplane as well as over IO links ControlLogix controllers can communicate over EtherNetIP ControlNet DeviceNet DH+ Remote IO and RS-232-C (DF1DH-485 protocol) networks and many third party process and device networks To provide communication for a ControlLogix controller install the appropriate communication interface module into the chassis

For detailed specifications see 1756 ControlLogix Controllers Specifications publication 1756-TD001

Cat No Description User Memory

1756-L72 ControlLogix controller 1 built-in USB port 4 MB

1756-L73 8 MB

1756-L74 16 MB

1756-L75 32 MB

1756-L61 ControlLogix controller 1 built-in RS-232 port 2 MB

1756-L62 4 MB

1756-L63 8 MB

1756-L64 16 MB

1756-L65 32 MB

1756-L61S GuardLogix safety controller 2 MB standard1 MB safety

1756-L62S 4 MB standard1 MB safety

1756-L63S 8 MB standard375 MB safety

1756-LSP GuardLogix safety partner (one is required for each GuardLogix controller) mdash

1756-L63XT ControlLogix-XT controller extreme environment 8 MB

IMPORTANT Scan time for a project loaded in a 1756-L64 or 1756-L65 controller may be slower than for the same project loaded in one of the other 1756-L6x controllers See the Logix5000 Controllers Instruction Execution Time and Memory Use Reference Manual publication 1756-RM087 for instruction execution times

Publication 1756-SG001P-EN-P - May 2011 27

Standard ControlLogix Controllers

The ControlLogix controller is part of the Logix5000 family of controllers A ControlLogix system includes the following

The ControlLogix controller available in different combinations of user memory

RSLogix 5000 programming software 1756 ControlLogix IO modules that reside in a 1756 chassis Separate communication modules for network communication

Features - Standard ControlLogix Controllers

Feature 1756-L61 1756-L62 1756-L63 1756-L64 1756-L65

1756-L72 1756-L73 1756-L74 1756-L75

Controller tasks 32 tasks 100 programstask Event tasks all event triggers

Built-in communication ports 1 port RS-232 serial 1 port USB

Communication options EtherNetIP ControlNet DeviceNet Data Highway Plus Remote IO SynchLink Third-party process and device networks

Built-in port Serial USB

Controller connections supported max 250 500

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Full support

Integrated motion EtherNetIP connection SERCOS interface Analog options (encoder input LDT input SSI input)

Programming languages Relay ladder Structured text Function block SFC

28 Publication 1756-SG001P-EN-P - May 2011

GuardLogix Controllers

A GuardLogix controller is a ControlLogix controller that also provides safety control The GuardLogix system is a dual controller solutionmdashyou must use a 1756-L6xS primary controller and a 1756-LSP safety partner to achieve SIL 3CAT 4

During development safety and standard have the same rules multiple programmers online editing and forcing are all allowed Once the project is tested and ready for final validation you set the Safety Task to a SIL 3 integrity level which is then enforced by the GuardLogix controller When safety memory is locked and protected the safety logic cant be modified and all safety functions operate with SIL 3 integrity On the standard side of the GuardLogix controller all functions operate like a regular Logix controller

Use Guard IO modules for field device connectivity on Ethernet or DeviceNet networks and for safety interlocking between GuardLogix controllers use Ethernet or ControlNet networks Multiple GuardLogix controllers can share safety data for zone to zone interlocking or a single GuardLogix controller can use remote distributed safety IO between different cellsareas

In addition to the standard features of a ControlLogix controller the GuardLogix controller has these safety-related features

Application Description

SIL 1 2 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508 and applications up to and including PLeCat4 according to ISO 13849-1 For more information see GuardLogix Controllers Systems Safety Reference Manual publication 1756-RM093 GuardLogix Controllers User Manual publication 1756-UM020 GuardLogix Safety Application Instruction Set Reference Manual publication 1756-RM095

Features - GuardLogix Controllers

Feature 1756-L61S 1756-L62S 1756-L63S 1756-LSP

Safety communication options Standard and safety EtherNetIP ControlNet DeviceNet

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Not supported

Programming languages Relay ladder

Publication 1756-SG001P-EN-P - May 2011 29

ControlLogix-XT Controllers

The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh corrosive environments

When used with FLEX IO-XT products the ControlLogix-XT system can withstand temperatures range from -2070 C (-4158 F)

When used independently the ControlLogix-XT system can withstand temperature ranges from -2570 C (-13158 F)

Redundant ControlLogix Controllers

The ControlLogix controller supports controller redundancy In a redundant controller system you need these components

Two 1756 chassis each with the following the same ndash Number of slots

ndash Modules in the same slots

ndash Redundancy firmware revisions in each module

ndash Two additional ControlNet nodes outside the redundant chassis pair

You need one of these redundancy modules

One 1756-RM module per chassis that supports the followingndash Two 1756-L61 1756-L62 1761-L63 controllers or one 1756-L64

controller

ndash Maximum of seven communication modules which can be 1756-CN2 series B 1756-CN2R series B and 1756-EN2T modules

ndash One 1756-RMCx cable

One 1757-SRM module per chassis that supports the followingndash One 1756-L61 1756-L62 1756-L63 1756-L64 controller

ndash Maximum of seven communication modules which can be 1756-CNB series D or E 1756-CNBR series D or E 1756-ENBT and 1756-EWEB modules

ndash One 1757-SRCx cable

30 Publication 1756-SG001P-EN-P - May 2011

Accessories - Controllers

Memory Cards

Memory cards offer nonvolatile memory to permanently store a user program and tag data on a controller The 1756-L7x ControlLogix controller comes with 1784-SD1 Secure Digital (SD) card already installed The 1756-L6x controllers support optional CompactFlash cards that you purchase separately The memory card installs in a socket on the controller Through RSLogix 5000 software you can manually trigger the controller to save to or load from nonvolatile memory or configure the controller to load from nonvolatile memory on powerup

The GuardLogix controller does not support user program storage or retrieval by using a CompactFlash card

1756 Energy Storage Modules

Instead of a battery the 1756-L7x controller ships with a 1756-ESMCAP energy storage module (ESM) already installed

Attribute 1784-CF64 1784-CF128 1784-SD1 1784-SD2

Memory 64 MB 128 MB 1 GB 2 GB

Supported controllers 1756-L6x 1756-L7x

Weight approx 142 g (05 oz) 176 g (0062 oz)

Cat No Description

1756-ESMCAP Capacitor-based energy-storage module Comes with the controller

1756-EMNSE ESM without WallClockTime backup power Additionally you can use this ESM with a 1756-L73 (8 MB) or smaller memory-sized controller only

Use this ESM if your application requires that the installed ESM deplete its residual energy to 40 microJoule or less before transporting it into or out of your application

1756-ESMNRM Energy-storage module that secures the controller by preventing the USB connection and SD card useThis ESM provides your application an enhanced degree of security

Publication 1756-SG001P-EN-P - May 2011 31

1756 ControlLogix Batteries

Each 1756-L6x controller ships with a battery With a memory card installed the controller can be used without a battery If you do not use a battery current tag data will be at the state it was when the memory card was saved

ControlLogix Chassis The ControlLogix system is a modular system that requires a 1756 IO chassis Place any module into any slot The backplane provides a high-speed communication path between modules

All of the chassis are designed for horizontal-only back-panel mounting The chassis are available in these configurations

Standard chassis ControlLogix-XT chassis

For detailed specifications see 1756 ControlLogix Chassis Specifications Specifications publication 1756-TD006

Features - Chassis

Slot guides and snap-in retention for easy and secure module fit for any type of 1756 module

Direct mounting accommodates any 1756 power supply

Attribute 1756-BA1 1756-BA2 1756-BATM(1) 1756-BATA

Description Lithium battery (059 g) Lithium battery (059 g) Externally mounted battery assembly

Replacement lithium battery for 1756-BATM (5 g max lithium per each D cell contains 2 D cells)

ControlLogix controllers 1756-L61 1756-L62 1756-L63 series A

1756-L61 1756-L62 1756-L63 series B1756-L64 1756-L65

1756-L61 1756-L62 1756-L63 series A

1756-BATM battery module

GuardLogix controllers mdash 1756-L61S 1756-L62S 1756-L63S

mdash mdash

ControlLogix-XT controllers

mdash 1756-L63XT mdash mdash

(1) The 1756-BATM externally mounted battery assembly is highly recommended for use with all series A 1756-L6x controllers and provides longer battery life than the 1756-BA1 battery The 1756-BATM includes one 1756-BATA lithium battery assembly and a 1 m (328 ft) cable to connect housing to controller

32 Publication 1756-SG001P-EN-P - May 2011

Standard Chassis

The chassis backplane provides a high-speed communication path between modules and distributes power to each of the modules within the chassis

ControlLogix-XT Chassis

The ControlLogix-XT chassis support extreme temperature environments

Accessories - Chassis

Use a slot filler module to fill empty slots

Cat No Description Slots

1756-A4 ControlLogix standard chassis 4

1756-A7 7

1756-A10 10

1756-A13 13

1756-A17 17

Cat No Description Slots Temperature Range

1756-A4LXT ControlLogix-XT chassis 4 -2560 degC (-13140 degF)

1756-A5XT 5 -2570 degC (-13158 degF)

1756-A7LXT 7 -2560 degC (-13140 degF)

Cat No Description

1756-N2 Slot filler module for empty slots in standard ControlLogix chassis

1756-N2XT Slot filler module for empty slots in ControlLogix-XT chassis

Publication 1756-SG001P-EN-P - May 2011 33

ControlLogix Power Supplies

ControlLogix power supplies are used with the 1756 chassis to provide 12V 33V 5V and 24V DC power directly to the chassis backplane Select from these configurations

Standard power Redundant power ControlLogix-XT power

For detailed specifications see 1756 ControlLogix Power Supplies Specifications publication 1756-TD005

Standard Power Supplies

You mount a standard power supply directly on the left end of the chassis where it plugs directly into the backplane

ControlLogix-XT Power Supplies

The ControlLogix-XT power supplies support extreme temperature environments

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA72 ControlLogix standard AC 120V220V AC 85hellip265V AC Standard series A and series B

1756-PA75 120V220V AC 85hellip265V AC Standard series B

1756-PB72 ControlLogix standard DC 24V DC 18hellip32V DC Standard series A and series B

1756-PB75 24V DC 1832V DC Standard series B

1756-PC75 48V DC 30hellip60V DC Standard series B

1756-PH75 125V DC 90hellip143V DC Standard series B

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PAXT ControlLogix-XT AC power supply 85265V AC 120240V AC XT

1756-PBXT ControlLogix-XT DC power supply 24V DC 18hellip32V DC XT

34 Publication 1756-SG001P-EN-P - May 2011

Redundant Power Supplies

To build a redundant power supply system you need the following

Two redundant power supplies (both 1756-PA75R or 1756-PB75R) One 1756-PSCA2 chassis adapter module Two 1756-CPR2 cables to connect the power supplies to the

1756-PSCA2 chassis adapter module (091 m (3 ft) length) User-supplied annunciator wiring to connect the power supplies to the

input modules as needed

The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Accessories - Redundant Power Supplies

Visualization Products Visualization products together with Logix for control and NetLinx architecture for communication make up the Rockwell Automation Integrated Architecture strategy The visualization strategy combines Rockwell Automation expertise in Allen-Bradley electronic operator interface and industrialized personal computer hardware with Rockwell Software supervisory control software Current visualization products include the following

FactoryTalk View software PanelView Plus operator interface PanelView Plus CE operator interface Industrial computers and monitors

For more information see the Operator Interface catalog pages at httpwwwabcomenepubcatalogs1276221813761239781

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA75R ControlLogix redundant 120V220V AC 85hellip265V AC Standard series B

1756-PB75R 24V DC 192hellip32V DC Standard series B

Cat No Description Specifications

1756-PSCA2 Chassis adapter module Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Mounts directly to left side of 1756 chassis

1756-CPR2 Chassis adapter cable Connects redundant power supply to 1756-PCSA2 chassis adapter Length091 m (3 ft)

Publication 1756-SG001P-EN-P - May 2011 35

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

Example Configuration - Redundant IO System

The 1715 redundant IO system lets a ControlLogix controller communicate to a remote redundant IO chassis over an EtherNetIP network The 1715 redundant IO system provides fault tolerance and redundancy for critical processes by using a redundant adapter pair and multiple IO modules that have diagnostics

The redundant IO system must be connected to a ControlLogix system via an EtherNetIP network All connections are established via the Ethernet network by using the topologies supported by the 1756-EN2TR communication bridge

For detailed specifications see the 1715 Redundant IO System Specifications Technical Data publication 1715-TD001A-EN-P

1756

-RM

1756

-EN

2TR

IO B

ASE

1715

-A31

0

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

IO B

ASE

1715

-A31

0

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTADual

1715

-AEN

TR

1756

-EN

2TR

1756

-RM

1715

-AEN

TR

1715

-IO

1715

-IO

1715

-IO

1715

-IO

1715

-IO

1715

-IO

ControlLogix Primary Chassis ControlLogix Secondary Chassis

1715 Redundant IO System

Publication 1756-SG001P-EN-P - May 2011 7

ControlLogix IO Modules The ControlLogix architecture provides a wide range of input and output modules to span many applications from high-speed digital to process control The ControlLogix architecture uses a producerconsumer model so that input information and output status can be shared among multiple controllers

Each ControlLogix IO module mounts in a ControlLogix chassis and requires either a removable terminal block (RTB) or a 1492 interface module (IFM) to connect all field-side wiring RTBs and IFMs are not included with the IO modules They must be ordered separately

For detailed specifications see 1756 ControlLogix IO Modules Specifications publication 1756-TD002

AC Digital put Modules

AC Digital Output Modules

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

1756-IA8D 8 diagnostic inputs(4 pointsgroup)

120V AC 79hellip132V AC 1756-TBNH1756-TBSH

1756-IA16 16 inputs(8 pointsgroup)

120V AC 74hellip132V AC 1756-TBNH1756-TBSH

1756-IA16I 16 individually isolated inputs 120V AC 74hellip132V AC 1756-TBCH1756-TBS6H

1756-IA32 32 diagnostic inputs(4 pointsgroup)

120V AC 74hellip132V AC 1756-TBCH1756-TBS6H

1756-IM16I 16 individually isolated inputs 240V AC 159hellip265V AC 1756-TBCH1756-TBS6H

1756-IN16 16 inputs(8 pointsgroup)

24V AC 10hellip30V AC 1756-TBNH1756-TBSH

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

1756-OA8 8 outputs(4 pointsgroup)

120240V AC 79hellip265V AC 1756-TBNH1756-TBSH

1756-OA8D 8 diagnostic electronically fused outputs(4 pointsgroup)

120V AC 74hellip132V AC 1756-TBNH1756-TBSH

1756-OA8E 8 electronically fused outputs(4 pointsgroup)

120V AC 74hellip132V AC 1756-TBNH1756-TBSH

1756-OA16 16 mechanically fusedgroup outputs(8 pointsgroup)

120240V AC 74hellip265V AC 1756-TBNH1756-TBSH

1756-OA16I 16 individually isolated outputs

120240V AC 74hellip265V AC 1756-TBCH1756-TBS6H

1756-ON8 8 outputs(4 pointsgroup)

24V AC 10hellip30V AC current gt50 mA16hellip30V AC current lt50 mA

1756-TBNH1756-TBSH

8 Publication 1756-SG001P-EN-P - May 2011

DC Digital Input Modules

DC Digital Output Modules

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

1756-IB16 16 inputs(8 pointsgroup)

1224V DC sink 10312V DC 1756-TBNH1756-TBSH

1756-IB16D 16 diagnostic inputs(4 pointsgroup)

1224V DC sink 1030V DC 1756-TBCH1756-TBS6H

1756-IB16I 16 individually isolated inputs 1224V DC sinksource 1030V DC 1756-TBCH1756-TBS6H

1756-IB16ISOE 16 individually isolated sequence of events inputs

2448V DC sinksource 1055V DC 1756-TBCH1756-TBS6H

1756-IB32 32 inputs(16 pointsgroup)

1224V DC sink 10312V DC 1756-TBCH1756-TBS6H

1756-IC16 16 inputs(8 pointsgroup)

48V DC sink 3055V DC 60 degC (140 degC)3060V DC 55 degC (131 degC)

1756-TBNH1756-TBSH

1756-IG16 16 inputs(8 pointsgroup)

5V DC TTL source (Low=True)

4555V DC 1756-TBNH1756-TBSH

1756-IH16I 16 individually isolated inputs 125V DC sinksource 90146V DC 1756-TBCH1756-TBS6H

1756-IH16ISOE 16 individually isolated sequence of events inputs

125V DC sinksource 90140V DC 1756-TBCH1756-TBS6H

1756-IV16 16 inputs(8 pointsgroup)

1224V DC source 1030V DC 1756-TBNH1756-TBSH

1756-IV32 32 inputs(16 pointsgroup)

1224V DC source 1030V DC 1756-TBCH1756-TBS6H

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

1756-OB8 8 outputs 1224V DC source 1030V DC 1756-TBNH1756-TBSH

1756-OB8EI 8 electronically fused individually isolated outputs

1224V DC source 1030V DC 1756-TBCH1756-TBS6H

1756-OB8I 8 individually isolated outputs 1224V DC source 1030V DC 1756-TBCH1756-TBS6H

1756-OB16D 16 diagnostic outputs(8 pointsgroup)

24V DC source 19230V DC 1756-TBCH1756-TBS6H

1756-OB16E 16 electronically fused outputs(8 pointsgroup)

1224V DC source 10312V DC 1756-TBNH1756-TBSH

1756-OB16I 16 individually isolated outputs

1224V DC sinksource 1030V DC 1756-TBCH1756-TBS6H

1756-OB16IS 16 individually isolated outputs8 scheduled outputs

1224V DC sinksource 1030V DC 1756-TBCH1756-TBS6H

1756-OB32 32 outputs(16 pointsgroup)

1224V DC source 10312V DC 1756-TBCH1756-TBS6H

Publication 1756-SG001P-EN-P - May 2011 9

Contact Output Modules

Analog Input Modules

1756-OC8 8 outputs(4 pointsgroup)

48V DC source 3060V DC 1756-TBNH1756-TBSH

1756-OG16 16 (8 pointsgroup) 5V DC TTL source (Low=True)

4555V DC 1756-TBNH1756-TBSH

1756-OH8I 8 outputsindividually isolated

120V DC 90146V DC 1756-TBCH1756-TBS6H

1756-OV16E 16 electronically fused outputs(8 pointsgroup)

1224V DC sink 1030V DC 1756-TBNH1756-TBSH

1756-OV32E 32 electronically fused outputs (16 pointsgroup)

1224V DC sink 1030V DC 1756-TBCH1756-TBS6H

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

Cat No InputsOutputs Operating Voltage Range Removable Terminal Block

1756-OW16I 16 normally open individually isolated outputs 5150V DC10265V AC

1756-TBCH1756-TBS6H

1756-OX8I 8 normally open8 normally closed individually isolated outputs(2 pointsgroup)

5150V DC10265V AC

1756-TBCH1756-TBS6H

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-IF6CIS 6 individually isolated inputs current sourcing

0hellip21 mA 16 bits034 Abit

1756-TBNH1756-TBSH

1756-IF6I 6 individually isolated inputs plusmn105V0hellip105V0hellip525V0hellip21 mA

16 bits105V 343 Vbit0hellip105V 171 Vbit0hellip525V 86 Vbit0hellip21 mA 034 Abit

1756-TBNH1756-TBSH

1756-IF8 8 single-ended inputs4 differential inputs2 high-speed differential inputs

plusmn1025V01025V05125V0hellip205 mA

plusmn1025V 320 Vcnt (15 bits plus sign bipolar)0hellip1025V 160 Vcnt (16 bits)0hellip5125V 80 V cnt (16 bits)0hellip205mA 032 Acnt (16 bits)

1756-TBCH1756-TBS6H

10 Publication 1756-SG001P-EN-P - May 2011

Analog RTD and Thermocouple Modules

Analog Output Modules

1756-IF8H 8 differential voltage or current inputs HART interface

plusmn10V05V1hellip5V010V0hellip20 mA4hellip20 mA

16hellip21 bits 1756-TBCH1756-TBS6H

1756-IF16 16 single-ended inputs8 differential or 4 differential (high speed) inputs

plusmn105V0hellip105V0hellip525V0hellip21 mA

16 bits105V 343 Vbit0hellip105V 171 Vbit0hellip525V 86 Vbit0hellip21 mA 034 Abit

1756-TBCH1756-TBS6H

1756-IF16H 16 differential current inputs HART interface

0hellip20 mA4hellip20 mA

16hellip21 bits 1756-TBCH1756-TBS6H

Cat No InputsOutputs Range Resolution Removable Terminal Block

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-IR6I 6 individually isolated RTD inputs 1hellip487 2hellip1000 4hellip20008hellip4020

16 bits1hellip487 77 mbit2hellip1000 15 mbit4hellip2000 30 mbit8hellip4020 60 mbit

1756-TBNH1756-TBSH

1756-IT6I 6 individually isolated thermocouple inputs1 CJC

-12hellip78 mV-12hellip30 mV

16 bits-1278 mV 14 Vbit-1230 mV 07 Vbit

1756-TBNH1756-TBSH

1756-IT6I2 6 individually isolated thermocouple inputs2 CJC

-12hellip78 mV (14 V per bit)-12hellip30 mV (07 V per bit ndash high resolution range)

16 bits-1278 mV 14 Vbit-1230 mV 07 Vbit

1756-TBNH1756-TBSH

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-OF4 4 voltage or current outputs plusmn104V0hellip21 mA

Voltage15 bits across 105V 320 VbitCurrent15 bits across 21mA 650 nAbit

1756-TBNH1756-TBSH

1756-OF6CI 6 individually isolated outputs current

0hellip21 mA 13 bits across 21 mA (27 A) 1756-TBNH1756-TBSH

1756-OF6VI 6 individually isolated outputs voltage

plusmn105V 14 bits across 21V (13 mV)(13 bits across 105V +sign bit)

1756-TBNH1756-TBSH

1756-OF8 8 voltage or current outputs plusmn104V0hellip21 mA

15 bits across 21 mA - 650 nAbit15 bits across 104V - 320 Vbit

1756-TBNH1756-TBSH

1756-OF8H 8 voltage or current outputs HART interface

plusmn104V0hellip20 mA4hellip20 mA

15hellip16 bits 1756-TBNH1756-TBSH

Publication 1756-SG001P-EN-P - May 2011 11

Analog Combination Input and Output Module

Specialty IO Modules

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-IF4FXOF2F 4 high-speed sub-millisecond differential inputs2 high-speed voltage or current outputs

Inputplusmn105V0hellip105V0hellip525V0hellip21 mAOutputplusmn104V0hellip21 mA

InputApprox 14 bits across plusmn10V DC (21V total)plusmn10V 13 mVbit 14-bit effective0hellip105V 13 mVbit 13-bit effective0hellip525V 13 mVbit 12-bit effectiveApprox 12 bits across 21 mA0hellip21 mA 525 AbitOutput13 bits across 21 mA = 28 Abit14 bits across 218V = 13 mVbit

1756-TBCH1756-TBS6H

Cat No InputsOutputs Description Removable Terminal Block

1756-CFM 4 inputs (2 per channel) 2 outputs current sourcing

Configurable flowmeter module2 Flowmeter (F) inputs used for all modes2 Gate inputs used in Totalizer mode for proverstore count

1756-TBNH1756-TBSH

1756-HSC 2 counters each with 3 inputs (A B Z for gatereset)4 outputs (2 pointsgroup)

High-speed counter module5V operation 45hellip55V DC1224V operation 10hellip312V DC

1756-TBCH1756-TBS6H

1756-PLS Left section 2 groups of 4 outputs and 4 inputs eachCenter section resolver interface and IO controlRight section 2 groups of 4 outputs and 4 inputs each

Programmable limit switch module Requires 3 RTBs 1756-TBNH or 1756-TBSH

12 Publication 1756-SG001P-EN-P - May 2011

HART Smart Instrumentation

HART (Highway Addressable Remote Transmitter) is an open protocol designed to connect analog devices For HART connectivity select from products available from Rockwell Automation and our Encompass partners

Typical HART Configuration

HART Interfaces

Accessories - IO Modules

1756 Removable Terminal Blocks

Removable terminal blocks (RTBs) provide a flexible interconnection between your plant wiring and 1756 IO modules The RTB plugs into the front of the IO module The type of module determines which RTB you need You can choose screw-clamp or spring-clamp RTBs

RTBs are not shipped with IO modules You must order them separately The standard housing on the front of the wiring arm is not deep enough for 25 mm2

HART Devices

ControlLogix Controller with 1756-IF8H or 1756-OF8H module

If your application has Select Description

Analog and HART connectivity in one moduleNo external hardware required to access HART signalHART commands can be transmitted as unscheduled messagesSupports asset management software to HART device

1756-IF8H1756-IF16H1756-OF8H

Rockwell Automation analog IO modules

Data acquisition or control application with slow update requirements (such as a tank farm)No external hardware required to access HART signalDoes not connect directly to asset management software

MVI56-HART Prosoft interface

Analog and HART in one moduleInstrumentation in hazardous locations (FLEX Ex modules)HART commands can be transmitted as unscheduled messagesDirectly connects asset management software to HART devices

1794 FLEX IO1797 FLEX Ex IO

There are specific FLEX IO and FLEX Ex modules designed for HART systems These catalog numbers end in an H such as 1797-IE8H

Publication 1756-SG001P-EN-P - May 2011 13

(14 AWG) wiring If you plan to use 25 mm2 (14 AWG) wiring also order the extended housing

Wiring Systems

As an alternative to buying RTBs and connecting the wires yourself you can buy a wiring system of the following

Interface modules (IFMs) that provide the output terminal blocks for digital IO modules Use the pre-wired cables that match the IO module to the IFM

Analog interface modules (AIFMs) that provide the output terminal blocks for analog IO modules Use the pre-wired cables that match the IO module to the AIFM

IO module-ready cables One end of the cable assembly is an RTB that plugs into the front of the IO module The other end has individually color-coded conductors that connect to a standard terminal block

Attribute 1756-TBNH 1756-TBSH 1756-TBCH 1756-TBS6H 1756-TBE

Description 20-position NEMA screw-clamp removable block

20-pin spring-clamp removable terminal block with standard housing

36-pin cage-clamp removable terminal block with standard housing

36-pin spring-clamp removable terminal block with standard housing

Extended depth terminal block housing

Screw torque 08hellip1 Nbullm7hellip9 lbbullin

04 Nbullm44 lbbullin

mdash

Screwdriver width 8 mm (516 in) max

IO Module

RTBPre-wired Cable

Factory-wired

Interface Module (IFM)

Field Wiring

14 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Integrated Motion

The Logix architecture supports motion control components that work in a wide variety of machine architectures

Integrated motion on EtherNetIP supports a connection to Ethernet drives

The Kinetix integrated-motion solution uses a SERCOS interface module to perform multi-axis synchronized motion

Logix integrated motion supports the analog family of servo modules for controlling drivesactuators

Networked motion provides the ability to connect via the DeviceNet network to a single axis drive to perform point-to-point indexing

For detailed specifications on motion interface modules see 1756 ControlLogix Integrated Motion Specifications publication 1756-TD004

For more information see these publications

Motion Analyzer CD to size your motion application and to make final component selection Download the software from httpwwwabcommotionsoftwareanalyzerhtml

Kinetix Motion Control Selection Guide publication GMC-SG001 to verify drive motor and accessory specifications

Integrated Motion on an EtherNetIP Network

Product Consideration

Drive that supports EtherNetIP connections Unlimited velocity torque and Vhz configured drives Kinetix 6500 drives PowerFlex 755 drives

ControlLogix controller As many as 100 drives per controller

ControlLogix EtherNetIP communication module 1hellip8 position configured drives with 1756-EN2TR module 1hellip255 position configured drives with 1756-EN3TR module

Publication 1756-SG001P-EN-P - May 2011 15

SERCOS Interface Modules

The SERCOS interface modules can connect to these servo drives

2093 Kinetix 2000 multi-axis servo drive 2094 Kinetix 6000 multi-axis servo drive 2099 Kinetix 7000 high-power servo drive 2098 Ultra3000 SERCOS servo drive

ControlLogix Controller

PanelView Plus Terminal

Workstations

POINT IO ModulesDrive with EtherNetIP Connection

Cat No Description Number of Axis

1756-M16SE Rockwell Automation SERCOS interface modules 16

1756-M08SE 8

1756-M03SE 3

1756-M08SEG SERCOS interface drives that are Extended Pack Profile compliant 8

16 Publication 1756-SG001P-EN-P - May 2011

Analog Motion Interface Modules

RSLogix 5000 Software1756-MxxSE Module

ControlLogix Controller

Three-phase Input Power

Line Interface Module

Integrated Axis Module

Motor Motor Feedback

Axis Modules

Slot Filler Module

Shunt Module

SERCOS Fiber-optic RingKinetix 6000 Multi-axis Servo Drive

Cat No Description Number of Axis

1756-M02AE Analog servo interface drives with quadrature feedback 2

1756-HYD02 Analog hydraulic servo interface drives LDT feedback 2

1756-M02AS Analog servo interface drives with SSI feedback 2

Publication 1756-SG001P-EN-P - May 2011 17

ControlLogix Communication Modules

Separate communication modules are available for different networks Install multiple communication modules into the ControlLogix backplane to bridge or route control and information data between different networks You can route a message through a maximum of four chassis (eight communication hops) You do not need a ControlLogix controller in the chassis

For detailed specifications see 1756 ControlLogix Network Specifications publication 1756-TD003

Application Network Page

Plant management (material handling) Configuration data collection and control on a single high-speed network Time-critical applications with no established schedule Inclusion of commercial technologies (such as video over IP) InternetIntranet connection Integrated CIP motion and safety

EtherNetIP network 19

High-speed transfer of time-critical data between controllers and IO devices Deterministic and repeatable data delivery Media redundancy Intrinsic safety Redundant controller systems

ControlNet network 20

Connections of low-level devices directly to plant floor controllers without interfacing them through IO modules

Data sent as needed More diagnostics for improved data collection and fault detection Less wiring and reduced start-up time than a traditional hard-wired system

DeviceNet network 21

Plant-wide and cell-level data sharing with program maintenance Data sent regularly Transfer of information between controllers

Data Highway Plus network 23

Connections between controllers and IO adapters Data sent regularly Distributed control so that each controller has its own IO and communicates with a

supervisory controller

Remote IO network 23

Fieldbus transmitters and actuators Closed-loop control Process automation

Foundation Fieldbus network 25

18 Publication 1756-SG001P-EN-P - May 2011

EtherNetIP Communication Modules

The Ethernet Industrial (EtherNetIP) network protocol is an open industrial-networking standard that supports both real-time IO messaging and message exchange The EtherNetIP network uses off-the-shelf Ethernet communication chips and physical media

Accessories - EtherNetIP Network

Cat No Description Media Communication Rate

CIP Motion Axes max

TCPIP Connections

Logix Connections

1756-EN2F EtherNetIP bridge fiber Fiber 100 Mbps 8 128 256

1756-EN2T EtherNetIP bridge copper Copper 10100 Mbps 8 128 256

1756-EN2TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 8 128 256

1756-EN3TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 255 128 256

1756-ENBT EtherNetIP bridge copper Copper 10100 Mbps mdash 64 128

1756-EWEB Ethernet web server module Copper 10100 Mbps mdash 64 128

1756-EN2TXT ControlLogix-XT extended temperature EtherNetIP bridge copper for extreme environments

Copper 10100 Mbps 8 128 256

Cat No Description Specifications

1585J-M8PBJM-x Ethernet RJ45 patchcordx = 2 (2 m) 5 (5 m) or 10 (10 m)

8-conductor Teal Riser PVC Cable (Flex Rated cable also available)

1585J-M8CC-H RJ45 insulation displacement connector (IDC) 01280325 mm2 (26hellip22 AWG) Cat 6 IDC no tool required

1585J-M8CC-C RJ45 crimp connector with boot qty = 50 pieces 01280205 mm2 (26hellip24 AWG Cat 5e requires crimp tool for assembly

1585A-Jcrimp Crimp tool mdash

9300-RADES Remote access dial-in kit 56 Kbps modem connection to devices on an Ethernet network includes pre-configured modem communication module DIN rail mounting hardware associated cables

Publication 1756-SG001P-EN-P - May 2011 19

Example Configuration - EtherNetIP Network

ControlNet Communication ModulesThe ControlNet network combines the functionality of an IO network and a peer-to-peer network providing high-speed performance The ControlNet network provides deterministic repeatable transfers of critical control data

FirewallRouter

Stratix Switch

Stratix Switch

Stratix Switch

Powermonitor 3000PowerFlex 70

Ethernet PLC-5

MicroLogix

Ethernet SLC 500

1756 IO

1794 IO

1761-NET-ENI

ControlNet

DeviceNet

1734 IO

RSLinxPanelView Plus

1769-L35E CompactLogix

Cat No Description Communication Rate

Logix Connections Number of Nodes

1756-CN2B ControlNet bridge standard media 5 Mbps 128(1) 99

1756-CN2RB ControlNet bridge redundant media 5 Mbps 128(1) 99

1756-CNB ControlNet bridge standard media 5 Mbps 64(2) 99

1756-CNBR ControlNet bridge redundant media 5 Mbps 64(2) 99

1756-CN2RXT ControlLogix-XT extended temperature ControlNet bridge redundant media

5 Mbps 128(1) 99

(1) 128 connections are available for standard use An additional three connections are reserved for redundant control

(2) Recommend using only 4048 Logix connections for IO

20 Publication 1756-SG001P-EN-P - May 2011

Example Configuration - ControlNet Network

Example Configuration - Redundant ControlNet Media

For information on ControlNet media see ControlNet Media System Components List AG-PA002

DeviceNet Communication Module

The DeviceNet network provides connections between simple industrial devices (such as sensors and actuators) and higher-level devices (such as controllers and computers)

1784-U2CNPanelView Plus

1788-CN2DN

DeviceNetPowerFlex 700SPLC-540CControlLogix

Redundant Media

ControlLogix1756-CNBR

ControlNet Node

ControlNet Node

Cat No Description Communication Rate Number of Nodes

1756-DNB DeviceNet bridge 125 Kbps (500 m max)250 Kbps (250 m max)500 Kbps (100 m max)

64

Publication 1756-SG001P-EN-P - May 2011 21

Example Configuration - DeviceNet Network

Accessories - DeviceNet Network

PLC-51771-SDN ControlLogix

1756-DNB

Ultra3000

PanelView Plus1784-U2DN

Ultra5000

IO

Motor starter

PowerFlex AC

Sensor Pushbuttons

LightsBar Code Scanner

Cat No Description

KwikLink Lite flat media KwikLink Lite flat media is a newer ODVA-approved solution for wiring DeviceNet networks Drop-lines for connecting nodes are added by using the KwikLink Lite two-piece connectors This cable system supports the intermixing of DeviceNet cable types (thin-round with flat) All of the KwikLink Lite connectors provide insulation displacement technology with reduced assembly time

KwikLink flat media The KwikLink flat media system provides a modular cabling method with its flat 4-wire cable and insulation displacement connectors (IDCs) The KwikLink system allows nodes to be added to the network without severing the trunkline Cutting or stripping of the trunkline is eliminated as is the need for predetermined cable lengths

Round media Round trunk cable is available in bulk spools or as pre-molded cordsets or patchcords in varying lengths A wide variety of rugged durable DeviceNet components is available for use in round trunk systems Stainless steel versions of round cable system components are also available Thick-trunk round media systems use thick cable for maximum DeviceNet trunk line length Round media thin-trunk systems use thin cable to reduce maximum trunk line distances with a more

compact and cost-effective installation for some applications Thin-cable outer jacket material is TPE for additional chemical resistance

22 Publication 1756-SG001P-EN-P - May 2011

Data Highway Plus and Remote IO Communication Modules

The Data Highway Plus network supports messaging between devices The remote IO link connects to remote IO chassis and other intelligent devices

The 1756-DHRIO module supports messaging between devices on DH+ networks The remote IO functionality enables the module to act as a scanner for transferring digital and block-transfer data to and from remote IO devices

The 1756-RIO module can act as a scanner or adapter on a remote IO network In addition to digital and block-transfer data the 1756-RIO module transfers analog and specialty data without message instructions

Cat No Description Communication Rate DH+ Connections RIO Connections Maximum Recommended Logix Connections

1756-DHRIO Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

1756-RIO Remote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

mdash Remote IO scanner or adapter32 physical racks (076) any combination of rack size and block transfers

10 scheduled IO

1756-DHRIOXT ControlLogix-XT extended temperature Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

Publication 1756-SG001P-EN-P - May 2011 23

Example Configuration - DH+ Network

Example Configuration - Remote IO Network

Accessories - DH+ and Remote IO Networks

PanelView Plus

PLC-5 1784-U2DHPRSLogix 5000

ControlLogix1756-DHRIO

SLC 504

PanelView PlusPLC-5

1791 IO1794 IO

1756-RIO as a Remote IO Adapter

1756-DHRIO as a Remote IO Scanner

Cat No Description Specifications

1770-CD Cable to connect communication module to DH+ network Belden 9463 twinaxial

9300-RADKIT Remote access dial-in kit 56 Kbps modem connection to devices on a DH+ network includes pre-configured modem communication module DIN rail mounting hardware associated cables

24 Publication 1756-SG001P-EN-P - May 2011

FOUNDATION Fieldbus Linking Devices

The FOUNDATION Fieldbus protocol is a network designed for distributed control of process applications

Example Configuration - Bridge to EtherNetIP Network

Cat No Description Communication Rate Number of H1 Ports

Devices per H1 Link

Devices per Linking Device

1757FFLD2 FOUNDATION Fieldbus bridge to an Ethernet network

FOUNDATION Fieldbus 3125 KbpsEtherNetIP 10100 Mbps

2 16(8hellip10 recommended)

32

1757-FFLD4 4 64

1757-FFLDC2 FOUNDATION Fieldbus bridge to a ControlNet network

FOUNDATION Fieldbus 3125 KbpsControlNet 5 Mbps

2 16(8hellip10 recommended)

32

1757-FFLDC4 4 64

FactoryTalk View SERSFieldbusRSLogix 5000

1757-FFLD4

H1(1)

H1(2)H1(3)H1(4)

HSEIP

Publication 1756-SG001P-EN-P - May 2011 25

Example Configuration - Bridge to ControlNet Network

Other Connectivity Options

ControlLogix RedundancyFactoryTalk View SERSFieldbusRSLogix 5000

ControlNet Redundant Media

1757-FFLDC2

FF H1

EtherNetIP

Option Consideration

USB connection The 1756-L7x controller has a USB port in place of the serial port If your application requires RS-232 functionality see the many Encompass partners at httpwwwrockwellautomationcomencompass

Serial connection The serial port on the 1756-L6x controller is compatible with RS-232 serial communication The serial port supports the DF1 protocol to communicate with other devices on the serial linkTo use Logix5000 controllers on Modbus you connect through the serial port and execute a specific ladder logic routine The controller project is available with RSLogix 5000 Enterprise programming software For more information see Using Logix5000 Controllers as Masters or Slaves on Modbus Application Solution publication CIG-AP129

DH-485 network The controller serial port is compatible with DH-485 communication The DH-485 connection does support remote programming and monitoring via RSLogix 5000 softwareOr add a DH-485 communication bridge module (cat no 1756-DH485)

SynchLink network The SynchLink communication module (1756-SYNCH) provides time synchronization and data broadcasting capabilities for distributed motion and coordinated drive control The module connects a ControlLogix chassis to a SynchLink fiber-optic communication link

26 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Controllers The ControlLogix controller provides a scalable controller solution that is capable of addressing a large amount of IO points

The controller can be placed into any slot of a ControlLogix chassis and multiple controllers can be installed in the same chassis Multiple controllers in the same chassis communicate with each other over the backplane (just as controllers can communicate over networks) but operate independently

ControlLogix controllers can monitor and control IO across the ControlLogix backplane as well as over IO links ControlLogix controllers can communicate over EtherNetIP ControlNet DeviceNet DH+ Remote IO and RS-232-C (DF1DH-485 protocol) networks and many third party process and device networks To provide communication for a ControlLogix controller install the appropriate communication interface module into the chassis

For detailed specifications see 1756 ControlLogix Controllers Specifications publication 1756-TD001

Cat No Description User Memory

1756-L72 ControlLogix controller 1 built-in USB port 4 MB

1756-L73 8 MB

1756-L74 16 MB

1756-L75 32 MB

1756-L61 ControlLogix controller 1 built-in RS-232 port 2 MB

1756-L62 4 MB

1756-L63 8 MB

1756-L64 16 MB

1756-L65 32 MB

1756-L61S GuardLogix safety controller 2 MB standard1 MB safety

1756-L62S 4 MB standard1 MB safety

1756-L63S 8 MB standard375 MB safety

1756-LSP GuardLogix safety partner (one is required for each GuardLogix controller) mdash

1756-L63XT ControlLogix-XT controller extreme environment 8 MB

IMPORTANT Scan time for a project loaded in a 1756-L64 or 1756-L65 controller may be slower than for the same project loaded in one of the other 1756-L6x controllers See the Logix5000 Controllers Instruction Execution Time and Memory Use Reference Manual publication 1756-RM087 for instruction execution times

Publication 1756-SG001P-EN-P - May 2011 27

Standard ControlLogix Controllers

The ControlLogix controller is part of the Logix5000 family of controllers A ControlLogix system includes the following

The ControlLogix controller available in different combinations of user memory

RSLogix 5000 programming software 1756 ControlLogix IO modules that reside in a 1756 chassis Separate communication modules for network communication

Features - Standard ControlLogix Controllers

Feature 1756-L61 1756-L62 1756-L63 1756-L64 1756-L65

1756-L72 1756-L73 1756-L74 1756-L75

Controller tasks 32 tasks 100 programstask Event tasks all event triggers

Built-in communication ports 1 port RS-232 serial 1 port USB

Communication options EtherNetIP ControlNet DeviceNet Data Highway Plus Remote IO SynchLink Third-party process and device networks

Built-in port Serial USB

Controller connections supported max 250 500

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Full support

Integrated motion EtherNetIP connection SERCOS interface Analog options (encoder input LDT input SSI input)

Programming languages Relay ladder Structured text Function block SFC

28 Publication 1756-SG001P-EN-P - May 2011

GuardLogix Controllers

A GuardLogix controller is a ControlLogix controller that also provides safety control The GuardLogix system is a dual controller solutionmdashyou must use a 1756-L6xS primary controller and a 1756-LSP safety partner to achieve SIL 3CAT 4

During development safety and standard have the same rules multiple programmers online editing and forcing are all allowed Once the project is tested and ready for final validation you set the Safety Task to a SIL 3 integrity level which is then enforced by the GuardLogix controller When safety memory is locked and protected the safety logic cant be modified and all safety functions operate with SIL 3 integrity On the standard side of the GuardLogix controller all functions operate like a regular Logix controller

Use Guard IO modules for field device connectivity on Ethernet or DeviceNet networks and for safety interlocking between GuardLogix controllers use Ethernet or ControlNet networks Multiple GuardLogix controllers can share safety data for zone to zone interlocking or a single GuardLogix controller can use remote distributed safety IO between different cellsareas

In addition to the standard features of a ControlLogix controller the GuardLogix controller has these safety-related features

Application Description

SIL 1 2 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508 and applications up to and including PLeCat4 according to ISO 13849-1 For more information see GuardLogix Controllers Systems Safety Reference Manual publication 1756-RM093 GuardLogix Controllers User Manual publication 1756-UM020 GuardLogix Safety Application Instruction Set Reference Manual publication 1756-RM095

Features - GuardLogix Controllers

Feature 1756-L61S 1756-L62S 1756-L63S 1756-LSP

Safety communication options Standard and safety EtherNetIP ControlNet DeviceNet

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Not supported

Programming languages Relay ladder

Publication 1756-SG001P-EN-P - May 2011 29

ControlLogix-XT Controllers

The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh corrosive environments

When used with FLEX IO-XT products the ControlLogix-XT system can withstand temperatures range from -2070 C (-4158 F)

When used independently the ControlLogix-XT system can withstand temperature ranges from -2570 C (-13158 F)

Redundant ControlLogix Controllers

The ControlLogix controller supports controller redundancy In a redundant controller system you need these components

Two 1756 chassis each with the following the same ndash Number of slots

ndash Modules in the same slots

ndash Redundancy firmware revisions in each module

ndash Two additional ControlNet nodes outside the redundant chassis pair

You need one of these redundancy modules

One 1756-RM module per chassis that supports the followingndash Two 1756-L61 1756-L62 1761-L63 controllers or one 1756-L64

controller

ndash Maximum of seven communication modules which can be 1756-CN2 series B 1756-CN2R series B and 1756-EN2T modules

ndash One 1756-RMCx cable

One 1757-SRM module per chassis that supports the followingndash One 1756-L61 1756-L62 1756-L63 1756-L64 controller

ndash Maximum of seven communication modules which can be 1756-CNB series D or E 1756-CNBR series D or E 1756-ENBT and 1756-EWEB modules

ndash One 1757-SRCx cable

30 Publication 1756-SG001P-EN-P - May 2011

Accessories - Controllers

Memory Cards

Memory cards offer nonvolatile memory to permanently store a user program and tag data on a controller The 1756-L7x ControlLogix controller comes with 1784-SD1 Secure Digital (SD) card already installed The 1756-L6x controllers support optional CompactFlash cards that you purchase separately The memory card installs in a socket on the controller Through RSLogix 5000 software you can manually trigger the controller to save to or load from nonvolatile memory or configure the controller to load from nonvolatile memory on powerup

The GuardLogix controller does not support user program storage or retrieval by using a CompactFlash card

1756 Energy Storage Modules

Instead of a battery the 1756-L7x controller ships with a 1756-ESMCAP energy storage module (ESM) already installed

Attribute 1784-CF64 1784-CF128 1784-SD1 1784-SD2

Memory 64 MB 128 MB 1 GB 2 GB

Supported controllers 1756-L6x 1756-L7x

Weight approx 142 g (05 oz) 176 g (0062 oz)

Cat No Description

1756-ESMCAP Capacitor-based energy-storage module Comes with the controller

1756-EMNSE ESM without WallClockTime backup power Additionally you can use this ESM with a 1756-L73 (8 MB) or smaller memory-sized controller only

Use this ESM if your application requires that the installed ESM deplete its residual energy to 40 microJoule or less before transporting it into or out of your application

1756-ESMNRM Energy-storage module that secures the controller by preventing the USB connection and SD card useThis ESM provides your application an enhanced degree of security

Publication 1756-SG001P-EN-P - May 2011 31

1756 ControlLogix Batteries

Each 1756-L6x controller ships with a battery With a memory card installed the controller can be used without a battery If you do not use a battery current tag data will be at the state it was when the memory card was saved

ControlLogix Chassis The ControlLogix system is a modular system that requires a 1756 IO chassis Place any module into any slot The backplane provides a high-speed communication path between modules

All of the chassis are designed for horizontal-only back-panel mounting The chassis are available in these configurations

Standard chassis ControlLogix-XT chassis

For detailed specifications see 1756 ControlLogix Chassis Specifications Specifications publication 1756-TD006

Features - Chassis

Slot guides and snap-in retention for easy and secure module fit for any type of 1756 module

Direct mounting accommodates any 1756 power supply

Attribute 1756-BA1 1756-BA2 1756-BATM(1) 1756-BATA

Description Lithium battery (059 g) Lithium battery (059 g) Externally mounted battery assembly

Replacement lithium battery for 1756-BATM (5 g max lithium per each D cell contains 2 D cells)

ControlLogix controllers 1756-L61 1756-L62 1756-L63 series A

1756-L61 1756-L62 1756-L63 series B1756-L64 1756-L65

1756-L61 1756-L62 1756-L63 series A

1756-BATM battery module

GuardLogix controllers mdash 1756-L61S 1756-L62S 1756-L63S

mdash mdash

ControlLogix-XT controllers

mdash 1756-L63XT mdash mdash

(1) The 1756-BATM externally mounted battery assembly is highly recommended for use with all series A 1756-L6x controllers and provides longer battery life than the 1756-BA1 battery The 1756-BATM includes one 1756-BATA lithium battery assembly and a 1 m (328 ft) cable to connect housing to controller

32 Publication 1756-SG001P-EN-P - May 2011

Standard Chassis

The chassis backplane provides a high-speed communication path between modules and distributes power to each of the modules within the chassis

ControlLogix-XT Chassis

The ControlLogix-XT chassis support extreme temperature environments

Accessories - Chassis

Use a slot filler module to fill empty slots

Cat No Description Slots

1756-A4 ControlLogix standard chassis 4

1756-A7 7

1756-A10 10

1756-A13 13

1756-A17 17

Cat No Description Slots Temperature Range

1756-A4LXT ControlLogix-XT chassis 4 -2560 degC (-13140 degF)

1756-A5XT 5 -2570 degC (-13158 degF)

1756-A7LXT 7 -2560 degC (-13140 degF)

Cat No Description

1756-N2 Slot filler module for empty slots in standard ControlLogix chassis

1756-N2XT Slot filler module for empty slots in ControlLogix-XT chassis

Publication 1756-SG001P-EN-P - May 2011 33

ControlLogix Power Supplies

ControlLogix power supplies are used with the 1756 chassis to provide 12V 33V 5V and 24V DC power directly to the chassis backplane Select from these configurations

Standard power Redundant power ControlLogix-XT power

For detailed specifications see 1756 ControlLogix Power Supplies Specifications publication 1756-TD005

Standard Power Supplies

You mount a standard power supply directly on the left end of the chassis where it plugs directly into the backplane

ControlLogix-XT Power Supplies

The ControlLogix-XT power supplies support extreme temperature environments

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA72 ControlLogix standard AC 120V220V AC 85hellip265V AC Standard series A and series B

1756-PA75 120V220V AC 85hellip265V AC Standard series B

1756-PB72 ControlLogix standard DC 24V DC 18hellip32V DC Standard series A and series B

1756-PB75 24V DC 1832V DC Standard series B

1756-PC75 48V DC 30hellip60V DC Standard series B

1756-PH75 125V DC 90hellip143V DC Standard series B

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PAXT ControlLogix-XT AC power supply 85265V AC 120240V AC XT

1756-PBXT ControlLogix-XT DC power supply 24V DC 18hellip32V DC XT

34 Publication 1756-SG001P-EN-P - May 2011

Redundant Power Supplies

To build a redundant power supply system you need the following

Two redundant power supplies (both 1756-PA75R or 1756-PB75R) One 1756-PSCA2 chassis adapter module Two 1756-CPR2 cables to connect the power supplies to the

1756-PSCA2 chassis adapter module (091 m (3 ft) length) User-supplied annunciator wiring to connect the power supplies to the

input modules as needed

The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Accessories - Redundant Power Supplies

Visualization Products Visualization products together with Logix for control and NetLinx architecture for communication make up the Rockwell Automation Integrated Architecture strategy The visualization strategy combines Rockwell Automation expertise in Allen-Bradley electronic operator interface and industrialized personal computer hardware with Rockwell Software supervisory control software Current visualization products include the following

FactoryTalk View software PanelView Plus operator interface PanelView Plus CE operator interface Industrial computers and monitors

For more information see the Operator Interface catalog pages at httpwwwabcomenepubcatalogs1276221813761239781

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA75R ControlLogix redundant 120V220V AC 85hellip265V AC Standard series B

1756-PB75R 24V DC 192hellip32V DC Standard series B

Cat No Description Specifications

1756-PSCA2 Chassis adapter module Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Mounts directly to left side of 1756 chassis

1756-CPR2 Chassis adapter cable Connects redundant power supply to 1756-PCSA2 chassis adapter Length091 m (3 ft)

Publication 1756-SG001P-EN-P - May 2011 35

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN ltFEFF9ad854c18cea51fa529b7528002000410064006f0062006500200050004400460020658766f8306e4f5c6210306b4f7f75283057307e30593002537052376642306e753b8cea3092670059279650306b4fdd306430533068304c3067304d307e3059300230c730b930af30c830c330d730d730ea30f330bf3067306e53705237307e305f306f30d730eb30fc30d57528306b9069305730663044307e305930023053306e8a2d5b9a30674f5c62103055308c305f0020005000440046002030d530a130a430eb306f3001004100630072006f0062006100740020304a30883073002000410064006f00620065002000520065006100640065007200200035002e003000204ee5964d3067958b304f30533068304c3067304d307e30593002gt KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

ControlLogix IO Modules The ControlLogix architecture provides a wide range of input and output modules to span many applications from high-speed digital to process control The ControlLogix architecture uses a producerconsumer model so that input information and output status can be shared among multiple controllers

Each ControlLogix IO module mounts in a ControlLogix chassis and requires either a removable terminal block (RTB) or a 1492 interface module (IFM) to connect all field-side wiring RTBs and IFMs are not included with the IO modules They must be ordered separately

For detailed specifications see 1756 ControlLogix IO Modules Specifications publication 1756-TD002

AC Digital put Modules

AC Digital Output Modules

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

1756-IA8D 8 diagnostic inputs(4 pointsgroup)

120V AC 79hellip132V AC 1756-TBNH1756-TBSH

1756-IA16 16 inputs(8 pointsgroup)

120V AC 74hellip132V AC 1756-TBNH1756-TBSH

1756-IA16I 16 individually isolated inputs 120V AC 74hellip132V AC 1756-TBCH1756-TBS6H

1756-IA32 32 diagnostic inputs(4 pointsgroup)

120V AC 74hellip132V AC 1756-TBCH1756-TBS6H

1756-IM16I 16 individually isolated inputs 240V AC 159hellip265V AC 1756-TBCH1756-TBS6H

1756-IN16 16 inputs(8 pointsgroup)

24V AC 10hellip30V AC 1756-TBNH1756-TBSH

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

1756-OA8 8 outputs(4 pointsgroup)

120240V AC 79hellip265V AC 1756-TBNH1756-TBSH

1756-OA8D 8 diagnostic electronically fused outputs(4 pointsgroup)

120V AC 74hellip132V AC 1756-TBNH1756-TBSH

1756-OA8E 8 electronically fused outputs(4 pointsgroup)

120V AC 74hellip132V AC 1756-TBNH1756-TBSH

1756-OA16 16 mechanically fusedgroup outputs(8 pointsgroup)

120240V AC 74hellip265V AC 1756-TBNH1756-TBSH

1756-OA16I 16 individually isolated outputs

120240V AC 74hellip265V AC 1756-TBCH1756-TBS6H

1756-ON8 8 outputs(4 pointsgroup)

24V AC 10hellip30V AC current gt50 mA16hellip30V AC current lt50 mA

1756-TBNH1756-TBSH

8 Publication 1756-SG001P-EN-P - May 2011

DC Digital Input Modules

DC Digital Output Modules

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

1756-IB16 16 inputs(8 pointsgroup)

1224V DC sink 10312V DC 1756-TBNH1756-TBSH

1756-IB16D 16 diagnostic inputs(4 pointsgroup)

1224V DC sink 1030V DC 1756-TBCH1756-TBS6H

1756-IB16I 16 individually isolated inputs 1224V DC sinksource 1030V DC 1756-TBCH1756-TBS6H

1756-IB16ISOE 16 individually isolated sequence of events inputs

2448V DC sinksource 1055V DC 1756-TBCH1756-TBS6H

1756-IB32 32 inputs(16 pointsgroup)

1224V DC sink 10312V DC 1756-TBCH1756-TBS6H

1756-IC16 16 inputs(8 pointsgroup)

48V DC sink 3055V DC 60 degC (140 degC)3060V DC 55 degC (131 degC)

1756-TBNH1756-TBSH

1756-IG16 16 inputs(8 pointsgroup)

5V DC TTL source (Low=True)

4555V DC 1756-TBNH1756-TBSH

1756-IH16I 16 individually isolated inputs 125V DC sinksource 90146V DC 1756-TBCH1756-TBS6H

1756-IH16ISOE 16 individually isolated sequence of events inputs

125V DC sinksource 90140V DC 1756-TBCH1756-TBS6H

1756-IV16 16 inputs(8 pointsgroup)

1224V DC source 1030V DC 1756-TBNH1756-TBSH

1756-IV32 32 inputs(16 pointsgroup)

1224V DC source 1030V DC 1756-TBCH1756-TBS6H

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

1756-OB8 8 outputs 1224V DC source 1030V DC 1756-TBNH1756-TBSH

1756-OB8EI 8 electronically fused individually isolated outputs

1224V DC source 1030V DC 1756-TBCH1756-TBS6H

1756-OB8I 8 individually isolated outputs 1224V DC source 1030V DC 1756-TBCH1756-TBS6H

1756-OB16D 16 diagnostic outputs(8 pointsgroup)

24V DC source 19230V DC 1756-TBCH1756-TBS6H

1756-OB16E 16 electronically fused outputs(8 pointsgroup)

1224V DC source 10312V DC 1756-TBNH1756-TBSH

1756-OB16I 16 individually isolated outputs

1224V DC sinksource 1030V DC 1756-TBCH1756-TBS6H

1756-OB16IS 16 individually isolated outputs8 scheduled outputs

1224V DC sinksource 1030V DC 1756-TBCH1756-TBS6H

1756-OB32 32 outputs(16 pointsgroup)

1224V DC source 10312V DC 1756-TBCH1756-TBS6H

Publication 1756-SG001P-EN-P - May 2011 9

Contact Output Modules

Analog Input Modules

1756-OC8 8 outputs(4 pointsgroup)

48V DC source 3060V DC 1756-TBNH1756-TBSH

1756-OG16 16 (8 pointsgroup) 5V DC TTL source (Low=True)

4555V DC 1756-TBNH1756-TBSH

1756-OH8I 8 outputsindividually isolated

120V DC 90146V DC 1756-TBCH1756-TBS6H

1756-OV16E 16 electronically fused outputs(8 pointsgroup)

1224V DC sink 1030V DC 1756-TBNH1756-TBSH

1756-OV32E 32 electronically fused outputs (16 pointsgroup)

1224V DC sink 1030V DC 1756-TBCH1756-TBS6H

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

Cat No InputsOutputs Operating Voltage Range Removable Terminal Block

1756-OW16I 16 normally open individually isolated outputs 5150V DC10265V AC

1756-TBCH1756-TBS6H

1756-OX8I 8 normally open8 normally closed individually isolated outputs(2 pointsgroup)

5150V DC10265V AC

1756-TBCH1756-TBS6H

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-IF6CIS 6 individually isolated inputs current sourcing

0hellip21 mA 16 bits034 Abit

1756-TBNH1756-TBSH

1756-IF6I 6 individually isolated inputs plusmn105V0hellip105V0hellip525V0hellip21 mA

16 bits105V 343 Vbit0hellip105V 171 Vbit0hellip525V 86 Vbit0hellip21 mA 034 Abit

1756-TBNH1756-TBSH

1756-IF8 8 single-ended inputs4 differential inputs2 high-speed differential inputs

plusmn1025V01025V05125V0hellip205 mA

plusmn1025V 320 Vcnt (15 bits plus sign bipolar)0hellip1025V 160 Vcnt (16 bits)0hellip5125V 80 V cnt (16 bits)0hellip205mA 032 Acnt (16 bits)

1756-TBCH1756-TBS6H

10 Publication 1756-SG001P-EN-P - May 2011

Analog RTD and Thermocouple Modules

Analog Output Modules

1756-IF8H 8 differential voltage or current inputs HART interface

plusmn10V05V1hellip5V010V0hellip20 mA4hellip20 mA

16hellip21 bits 1756-TBCH1756-TBS6H

1756-IF16 16 single-ended inputs8 differential or 4 differential (high speed) inputs

plusmn105V0hellip105V0hellip525V0hellip21 mA

16 bits105V 343 Vbit0hellip105V 171 Vbit0hellip525V 86 Vbit0hellip21 mA 034 Abit

1756-TBCH1756-TBS6H

1756-IF16H 16 differential current inputs HART interface

0hellip20 mA4hellip20 mA

16hellip21 bits 1756-TBCH1756-TBS6H

Cat No InputsOutputs Range Resolution Removable Terminal Block

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-IR6I 6 individually isolated RTD inputs 1hellip487 2hellip1000 4hellip20008hellip4020

16 bits1hellip487 77 mbit2hellip1000 15 mbit4hellip2000 30 mbit8hellip4020 60 mbit

1756-TBNH1756-TBSH

1756-IT6I 6 individually isolated thermocouple inputs1 CJC

-12hellip78 mV-12hellip30 mV

16 bits-1278 mV 14 Vbit-1230 mV 07 Vbit

1756-TBNH1756-TBSH

1756-IT6I2 6 individually isolated thermocouple inputs2 CJC

-12hellip78 mV (14 V per bit)-12hellip30 mV (07 V per bit ndash high resolution range)

16 bits-1278 mV 14 Vbit-1230 mV 07 Vbit

1756-TBNH1756-TBSH

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-OF4 4 voltage or current outputs plusmn104V0hellip21 mA

Voltage15 bits across 105V 320 VbitCurrent15 bits across 21mA 650 nAbit

1756-TBNH1756-TBSH

1756-OF6CI 6 individually isolated outputs current

0hellip21 mA 13 bits across 21 mA (27 A) 1756-TBNH1756-TBSH

1756-OF6VI 6 individually isolated outputs voltage

plusmn105V 14 bits across 21V (13 mV)(13 bits across 105V +sign bit)

1756-TBNH1756-TBSH

1756-OF8 8 voltage or current outputs plusmn104V0hellip21 mA

15 bits across 21 mA - 650 nAbit15 bits across 104V - 320 Vbit

1756-TBNH1756-TBSH

1756-OF8H 8 voltage or current outputs HART interface

plusmn104V0hellip20 mA4hellip20 mA

15hellip16 bits 1756-TBNH1756-TBSH

Publication 1756-SG001P-EN-P - May 2011 11

Analog Combination Input and Output Module

Specialty IO Modules

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-IF4FXOF2F 4 high-speed sub-millisecond differential inputs2 high-speed voltage or current outputs

Inputplusmn105V0hellip105V0hellip525V0hellip21 mAOutputplusmn104V0hellip21 mA

InputApprox 14 bits across plusmn10V DC (21V total)plusmn10V 13 mVbit 14-bit effective0hellip105V 13 mVbit 13-bit effective0hellip525V 13 mVbit 12-bit effectiveApprox 12 bits across 21 mA0hellip21 mA 525 AbitOutput13 bits across 21 mA = 28 Abit14 bits across 218V = 13 mVbit

1756-TBCH1756-TBS6H

Cat No InputsOutputs Description Removable Terminal Block

1756-CFM 4 inputs (2 per channel) 2 outputs current sourcing

Configurable flowmeter module2 Flowmeter (F) inputs used for all modes2 Gate inputs used in Totalizer mode for proverstore count

1756-TBNH1756-TBSH

1756-HSC 2 counters each with 3 inputs (A B Z for gatereset)4 outputs (2 pointsgroup)

High-speed counter module5V operation 45hellip55V DC1224V operation 10hellip312V DC

1756-TBCH1756-TBS6H

1756-PLS Left section 2 groups of 4 outputs and 4 inputs eachCenter section resolver interface and IO controlRight section 2 groups of 4 outputs and 4 inputs each

Programmable limit switch module Requires 3 RTBs 1756-TBNH or 1756-TBSH

12 Publication 1756-SG001P-EN-P - May 2011

HART Smart Instrumentation

HART (Highway Addressable Remote Transmitter) is an open protocol designed to connect analog devices For HART connectivity select from products available from Rockwell Automation and our Encompass partners

Typical HART Configuration

HART Interfaces

Accessories - IO Modules

1756 Removable Terminal Blocks

Removable terminal blocks (RTBs) provide a flexible interconnection between your plant wiring and 1756 IO modules The RTB plugs into the front of the IO module The type of module determines which RTB you need You can choose screw-clamp or spring-clamp RTBs

RTBs are not shipped with IO modules You must order them separately The standard housing on the front of the wiring arm is not deep enough for 25 mm2

HART Devices

ControlLogix Controller with 1756-IF8H or 1756-OF8H module

If your application has Select Description

Analog and HART connectivity in one moduleNo external hardware required to access HART signalHART commands can be transmitted as unscheduled messagesSupports asset management software to HART device

1756-IF8H1756-IF16H1756-OF8H

Rockwell Automation analog IO modules

Data acquisition or control application with slow update requirements (such as a tank farm)No external hardware required to access HART signalDoes not connect directly to asset management software

MVI56-HART Prosoft interface

Analog and HART in one moduleInstrumentation in hazardous locations (FLEX Ex modules)HART commands can be transmitted as unscheduled messagesDirectly connects asset management software to HART devices

1794 FLEX IO1797 FLEX Ex IO

There are specific FLEX IO and FLEX Ex modules designed for HART systems These catalog numbers end in an H such as 1797-IE8H

Publication 1756-SG001P-EN-P - May 2011 13

(14 AWG) wiring If you plan to use 25 mm2 (14 AWG) wiring also order the extended housing

Wiring Systems

As an alternative to buying RTBs and connecting the wires yourself you can buy a wiring system of the following

Interface modules (IFMs) that provide the output terminal blocks for digital IO modules Use the pre-wired cables that match the IO module to the IFM

Analog interface modules (AIFMs) that provide the output terminal blocks for analog IO modules Use the pre-wired cables that match the IO module to the AIFM

IO module-ready cables One end of the cable assembly is an RTB that plugs into the front of the IO module The other end has individually color-coded conductors that connect to a standard terminal block

Attribute 1756-TBNH 1756-TBSH 1756-TBCH 1756-TBS6H 1756-TBE

Description 20-position NEMA screw-clamp removable block

20-pin spring-clamp removable terminal block with standard housing

36-pin cage-clamp removable terminal block with standard housing

36-pin spring-clamp removable terminal block with standard housing

Extended depth terminal block housing

Screw torque 08hellip1 Nbullm7hellip9 lbbullin

04 Nbullm44 lbbullin

mdash

Screwdriver width 8 mm (516 in) max

IO Module

RTBPre-wired Cable

Factory-wired

Interface Module (IFM)

Field Wiring

14 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Integrated Motion

The Logix architecture supports motion control components that work in a wide variety of machine architectures

Integrated motion on EtherNetIP supports a connection to Ethernet drives

The Kinetix integrated-motion solution uses a SERCOS interface module to perform multi-axis synchronized motion

Logix integrated motion supports the analog family of servo modules for controlling drivesactuators

Networked motion provides the ability to connect via the DeviceNet network to a single axis drive to perform point-to-point indexing

For detailed specifications on motion interface modules see 1756 ControlLogix Integrated Motion Specifications publication 1756-TD004

For more information see these publications

Motion Analyzer CD to size your motion application and to make final component selection Download the software from httpwwwabcommotionsoftwareanalyzerhtml

Kinetix Motion Control Selection Guide publication GMC-SG001 to verify drive motor and accessory specifications

Integrated Motion on an EtherNetIP Network

Product Consideration

Drive that supports EtherNetIP connections Unlimited velocity torque and Vhz configured drives Kinetix 6500 drives PowerFlex 755 drives

ControlLogix controller As many as 100 drives per controller

ControlLogix EtherNetIP communication module 1hellip8 position configured drives with 1756-EN2TR module 1hellip255 position configured drives with 1756-EN3TR module

Publication 1756-SG001P-EN-P - May 2011 15

SERCOS Interface Modules

The SERCOS interface modules can connect to these servo drives

2093 Kinetix 2000 multi-axis servo drive 2094 Kinetix 6000 multi-axis servo drive 2099 Kinetix 7000 high-power servo drive 2098 Ultra3000 SERCOS servo drive

ControlLogix Controller

PanelView Plus Terminal

Workstations

POINT IO ModulesDrive with EtherNetIP Connection

Cat No Description Number of Axis

1756-M16SE Rockwell Automation SERCOS interface modules 16

1756-M08SE 8

1756-M03SE 3

1756-M08SEG SERCOS interface drives that are Extended Pack Profile compliant 8

16 Publication 1756-SG001P-EN-P - May 2011

Analog Motion Interface Modules

RSLogix 5000 Software1756-MxxSE Module

ControlLogix Controller

Three-phase Input Power

Line Interface Module

Integrated Axis Module

Motor Motor Feedback

Axis Modules

Slot Filler Module

Shunt Module

SERCOS Fiber-optic RingKinetix 6000 Multi-axis Servo Drive

Cat No Description Number of Axis

1756-M02AE Analog servo interface drives with quadrature feedback 2

1756-HYD02 Analog hydraulic servo interface drives LDT feedback 2

1756-M02AS Analog servo interface drives with SSI feedback 2

Publication 1756-SG001P-EN-P - May 2011 17

ControlLogix Communication Modules

Separate communication modules are available for different networks Install multiple communication modules into the ControlLogix backplane to bridge or route control and information data between different networks You can route a message through a maximum of four chassis (eight communication hops) You do not need a ControlLogix controller in the chassis

For detailed specifications see 1756 ControlLogix Network Specifications publication 1756-TD003

Application Network Page

Plant management (material handling) Configuration data collection and control on a single high-speed network Time-critical applications with no established schedule Inclusion of commercial technologies (such as video over IP) InternetIntranet connection Integrated CIP motion and safety

EtherNetIP network 19

High-speed transfer of time-critical data between controllers and IO devices Deterministic and repeatable data delivery Media redundancy Intrinsic safety Redundant controller systems

ControlNet network 20

Connections of low-level devices directly to plant floor controllers without interfacing them through IO modules

Data sent as needed More diagnostics for improved data collection and fault detection Less wiring and reduced start-up time than a traditional hard-wired system

DeviceNet network 21

Plant-wide and cell-level data sharing with program maintenance Data sent regularly Transfer of information between controllers

Data Highway Plus network 23

Connections between controllers and IO adapters Data sent regularly Distributed control so that each controller has its own IO and communicates with a

supervisory controller

Remote IO network 23

Fieldbus transmitters and actuators Closed-loop control Process automation

Foundation Fieldbus network 25

18 Publication 1756-SG001P-EN-P - May 2011

EtherNetIP Communication Modules

The Ethernet Industrial (EtherNetIP) network protocol is an open industrial-networking standard that supports both real-time IO messaging and message exchange The EtherNetIP network uses off-the-shelf Ethernet communication chips and physical media

Accessories - EtherNetIP Network

Cat No Description Media Communication Rate

CIP Motion Axes max

TCPIP Connections

Logix Connections

1756-EN2F EtherNetIP bridge fiber Fiber 100 Mbps 8 128 256

1756-EN2T EtherNetIP bridge copper Copper 10100 Mbps 8 128 256

1756-EN2TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 8 128 256

1756-EN3TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 255 128 256

1756-ENBT EtherNetIP bridge copper Copper 10100 Mbps mdash 64 128

1756-EWEB Ethernet web server module Copper 10100 Mbps mdash 64 128

1756-EN2TXT ControlLogix-XT extended temperature EtherNetIP bridge copper for extreme environments

Copper 10100 Mbps 8 128 256

Cat No Description Specifications

1585J-M8PBJM-x Ethernet RJ45 patchcordx = 2 (2 m) 5 (5 m) or 10 (10 m)

8-conductor Teal Riser PVC Cable (Flex Rated cable also available)

1585J-M8CC-H RJ45 insulation displacement connector (IDC) 01280325 mm2 (26hellip22 AWG) Cat 6 IDC no tool required

1585J-M8CC-C RJ45 crimp connector with boot qty = 50 pieces 01280205 mm2 (26hellip24 AWG Cat 5e requires crimp tool for assembly

1585A-Jcrimp Crimp tool mdash

9300-RADES Remote access dial-in kit 56 Kbps modem connection to devices on an Ethernet network includes pre-configured modem communication module DIN rail mounting hardware associated cables

Publication 1756-SG001P-EN-P - May 2011 19

Example Configuration - EtherNetIP Network

ControlNet Communication ModulesThe ControlNet network combines the functionality of an IO network and a peer-to-peer network providing high-speed performance The ControlNet network provides deterministic repeatable transfers of critical control data

FirewallRouter

Stratix Switch

Stratix Switch

Stratix Switch

Powermonitor 3000PowerFlex 70

Ethernet PLC-5

MicroLogix

Ethernet SLC 500

1756 IO

1794 IO

1761-NET-ENI

ControlNet

DeviceNet

1734 IO

RSLinxPanelView Plus

1769-L35E CompactLogix

Cat No Description Communication Rate

Logix Connections Number of Nodes

1756-CN2B ControlNet bridge standard media 5 Mbps 128(1) 99

1756-CN2RB ControlNet bridge redundant media 5 Mbps 128(1) 99

1756-CNB ControlNet bridge standard media 5 Mbps 64(2) 99

1756-CNBR ControlNet bridge redundant media 5 Mbps 64(2) 99

1756-CN2RXT ControlLogix-XT extended temperature ControlNet bridge redundant media

5 Mbps 128(1) 99

(1) 128 connections are available for standard use An additional three connections are reserved for redundant control

(2) Recommend using only 4048 Logix connections for IO

20 Publication 1756-SG001P-EN-P - May 2011

Example Configuration - ControlNet Network

Example Configuration - Redundant ControlNet Media

For information on ControlNet media see ControlNet Media System Components List AG-PA002

DeviceNet Communication Module

The DeviceNet network provides connections between simple industrial devices (such as sensors and actuators) and higher-level devices (such as controllers and computers)

1784-U2CNPanelView Plus

1788-CN2DN

DeviceNetPowerFlex 700SPLC-540CControlLogix

Redundant Media

ControlLogix1756-CNBR

ControlNet Node

ControlNet Node

Cat No Description Communication Rate Number of Nodes

1756-DNB DeviceNet bridge 125 Kbps (500 m max)250 Kbps (250 m max)500 Kbps (100 m max)

64

Publication 1756-SG001P-EN-P - May 2011 21

Example Configuration - DeviceNet Network

Accessories - DeviceNet Network

PLC-51771-SDN ControlLogix

1756-DNB

Ultra3000

PanelView Plus1784-U2DN

Ultra5000

IO

Motor starter

PowerFlex AC

Sensor Pushbuttons

LightsBar Code Scanner

Cat No Description

KwikLink Lite flat media KwikLink Lite flat media is a newer ODVA-approved solution for wiring DeviceNet networks Drop-lines for connecting nodes are added by using the KwikLink Lite two-piece connectors This cable system supports the intermixing of DeviceNet cable types (thin-round with flat) All of the KwikLink Lite connectors provide insulation displacement technology with reduced assembly time

KwikLink flat media The KwikLink flat media system provides a modular cabling method with its flat 4-wire cable and insulation displacement connectors (IDCs) The KwikLink system allows nodes to be added to the network without severing the trunkline Cutting or stripping of the trunkline is eliminated as is the need for predetermined cable lengths

Round media Round trunk cable is available in bulk spools or as pre-molded cordsets or patchcords in varying lengths A wide variety of rugged durable DeviceNet components is available for use in round trunk systems Stainless steel versions of round cable system components are also available Thick-trunk round media systems use thick cable for maximum DeviceNet trunk line length Round media thin-trunk systems use thin cable to reduce maximum trunk line distances with a more

compact and cost-effective installation for some applications Thin-cable outer jacket material is TPE for additional chemical resistance

22 Publication 1756-SG001P-EN-P - May 2011

Data Highway Plus and Remote IO Communication Modules

The Data Highway Plus network supports messaging between devices The remote IO link connects to remote IO chassis and other intelligent devices

The 1756-DHRIO module supports messaging between devices on DH+ networks The remote IO functionality enables the module to act as a scanner for transferring digital and block-transfer data to and from remote IO devices

The 1756-RIO module can act as a scanner or adapter on a remote IO network In addition to digital and block-transfer data the 1756-RIO module transfers analog and specialty data without message instructions

Cat No Description Communication Rate DH+ Connections RIO Connections Maximum Recommended Logix Connections

1756-DHRIO Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

1756-RIO Remote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

mdash Remote IO scanner or adapter32 physical racks (076) any combination of rack size and block transfers

10 scheduled IO

1756-DHRIOXT ControlLogix-XT extended temperature Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

Publication 1756-SG001P-EN-P - May 2011 23

Example Configuration - DH+ Network

Example Configuration - Remote IO Network

Accessories - DH+ and Remote IO Networks

PanelView Plus

PLC-5 1784-U2DHPRSLogix 5000

ControlLogix1756-DHRIO

SLC 504

PanelView PlusPLC-5

1791 IO1794 IO

1756-RIO as a Remote IO Adapter

1756-DHRIO as a Remote IO Scanner

Cat No Description Specifications

1770-CD Cable to connect communication module to DH+ network Belden 9463 twinaxial

9300-RADKIT Remote access dial-in kit 56 Kbps modem connection to devices on a DH+ network includes pre-configured modem communication module DIN rail mounting hardware associated cables

24 Publication 1756-SG001P-EN-P - May 2011

FOUNDATION Fieldbus Linking Devices

The FOUNDATION Fieldbus protocol is a network designed for distributed control of process applications

Example Configuration - Bridge to EtherNetIP Network

Cat No Description Communication Rate Number of H1 Ports

Devices per H1 Link

Devices per Linking Device

1757FFLD2 FOUNDATION Fieldbus bridge to an Ethernet network

FOUNDATION Fieldbus 3125 KbpsEtherNetIP 10100 Mbps

2 16(8hellip10 recommended)

32

1757-FFLD4 4 64

1757-FFLDC2 FOUNDATION Fieldbus bridge to a ControlNet network

FOUNDATION Fieldbus 3125 KbpsControlNet 5 Mbps

2 16(8hellip10 recommended)

32

1757-FFLDC4 4 64

FactoryTalk View SERSFieldbusRSLogix 5000

1757-FFLD4

H1(1)

H1(2)H1(3)H1(4)

HSEIP

Publication 1756-SG001P-EN-P - May 2011 25

Example Configuration - Bridge to ControlNet Network

Other Connectivity Options

ControlLogix RedundancyFactoryTalk View SERSFieldbusRSLogix 5000

ControlNet Redundant Media

1757-FFLDC2

FF H1

EtherNetIP

Option Consideration

USB connection The 1756-L7x controller has a USB port in place of the serial port If your application requires RS-232 functionality see the many Encompass partners at httpwwwrockwellautomationcomencompass

Serial connection The serial port on the 1756-L6x controller is compatible with RS-232 serial communication The serial port supports the DF1 protocol to communicate with other devices on the serial linkTo use Logix5000 controllers on Modbus you connect through the serial port and execute a specific ladder logic routine The controller project is available with RSLogix 5000 Enterprise programming software For more information see Using Logix5000 Controllers as Masters or Slaves on Modbus Application Solution publication CIG-AP129

DH-485 network The controller serial port is compatible with DH-485 communication The DH-485 connection does support remote programming and monitoring via RSLogix 5000 softwareOr add a DH-485 communication bridge module (cat no 1756-DH485)

SynchLink network The SynchLink communication module (1756-SYNCH) provides time synchronization and data broadcasting capabilities for distributed motion and coordinated drive control The module connects a ControlLogix chassis to a SynchLink fiber-optic communication link

26 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Controllers The ControlLogix controller provides a scalable controller solution that is capable of addressing a large amount of IO points

The controller can be placed into any slot of a ControlLogix chassis and multiple controllers can be installed in the same chassis Multiple controllers in the same chassis communicate with each other over the backplane (just as controllers can communicate over networks) but operate independently

ControlLogix controllers can monitor and control IO across the ControlLogix backplane as well as over IO links ControlLogix controllers can communicate over EtherNetIP ControlNet DeviceNet DH+ Remote IO and RS-232-C (DF1DH-485 protocol) networks and many third party process and device networks To provide communication for a ControlLogix controller install the appropriate communication interface module into the chassis

For detailed specifications see 1756 ControlLogix Controllers Specifications publication 1756-TD001

Cat No Description User Memory

1756-L72 ControlLogix controller 1 built-in USB port 4 MB

1756-L73 8 MB

1756-L74 16 MB

1756-L75 32 MB

1756-L61 ControlLogix controller 1 built-in RS-232 port 2 MB

1756-L62 4 MB

1756-L63 8 MB

1756-L64 16 MB

1756-L65 32 MB

1756-L61S GuardLogix safety controller 2 MB standard1 MB safety

1756-L62S 4 MB standard1 MB safety

1756-L63S 8 MB standard375 MB safety

1756-LSP GuardLogix safety partner (one is required for each GuardLogix controller) mdash

1756-L63XT ControlLogix-XT controller extreme environment 8 MB

IMPORTANT Scan time for a project loaded in a 1756-L64 or 1756-L65 controller may be slower than for the same project loaded in one of the other 1756-L6x controllers See the Logix5000 Controllers Instruction Execution Time and Memory Use Reference Manual publication 1756-RM087 for instruction execution times

Publication 1756-SG001P-EN-P - May 2011 27

Standard ControlLogix Controllers

The ControlLogix controller is part of the Logix5000 family of controllers A ControlLogix system includes the following

The ControlLogix controller available in different combinations of user memory

RSLogix 5000 programming software 1756 ControlLogix IO modules that reside in a 1756 chassis Separate communication modules for network communication

Features - Standard ControlLogix Controllers

Feature 1756-L61 1756-L62 1756-L63 1756-L64 1756-L65

1756-L72 1756-L73 1756-L74 1756-L75

Controller tasks 32 tasks 100 programstask Event tasks all event triggers

Built-in communication ports 1 port RS-232 serial 1 port USB

Communication options EtherNetIP ControlNet DeviceNet Data Highway Plus Remote IO SynchLink Third-party process and device networks

Built-in port Serial USB

Controller connections supported max 250 500

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Full support

Integrated motion EtherNetIP connection SERCOS interface Analog options (encoder input LDT input SSI input)

Programming languages Relay ladder Structured text Function block SFC

28 Publication 1756-SG001P-EN-P - May 2011

GuardLogix Controllers

A GuardLogix controller is a ControlLogix controller that also provides safety control The GuardLogix system is a dual controller solutionmdashyou must use a 1756-L6xS primary controller and a 1756-LSP safety partner to achieve SIL 3CAT 4

During development safety and standard have the same rules multiple programmers online editing and forcing are all allowed Once the project is tested and ready for final validation you set the Safety Task to a SIL 3 integrity level which is then enforced by the GuardLogix controller When safety memory is locked and protected the safety logic cant be modified and all safety functions operate with SIL 3 integrity On the standard side of the GuardLogix controller all functions operate like a regular Logix controller

Use Guard IO modules for field device connectivity on Ethernet or DeviceNet networks and for safety interlocking between GuardLogix controllers use Ethernet or ControlNet networks Multiple GuardLogix controllers can share safety data for zone to zone interlocking or a single GuardLogix controller can use remote distributed safety IO between different cellsareas

In addition to the standard features of a ControlLogix controller the GuardLogix controller has these safety-related features

Application Description

SIL 1 2 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508 and applications up to and including PLeCat4 according to ISO 13849-1 For more information see GuardLogix Controllers Systems Safety Reference Manual publication 1756-RM093 GuardLogix Controllers User Manual publication 1756-UM020 GuardLogix Safety Application Instruction Set Reference Manual publication 1756-RM095

Features - GuardLogix Controllers

Feature 1756-L61S 1756-L62S 1756-L63S 1756-LSP

Safety communication options Standard and safety EtherNetIP ControlNet DeviceNet

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Not supported

Programming languages Relay ladder

Publication 1756-SG001P-EN-P - May 2011 29

ControlLogix-XT Controllers

The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh corrosive environments

When used with FLEX IO-XT products the ControlLogix-XT system can withstand temperatures range from -2070 C (-4158 F)

When used independently the ControlLogix-XT system can withstand temperature ranges from -2570 C (-13158 F)

Redundant ControlLogix Controllers

The ControlLogix controller supports controller redundancy In a redundant controller system you need these components

Two 1756 chassis each with the following the same ndash Number of slots

ndash Modules in the same slots

ndash Redundancy firmware revisions in each module

ndash Two additional ControlNet nodes outside the redundant chassis pair

You need one of these redundancy modules

One 1756-RM module per chassis that supports the followingndash Two 1756-L61 1756-L62 1761-L63 controllers or one 1756-L64

controller

ndash Maximum of seven communication modules which can be 1756-CN2 series B 1756-CN2R series B and 1756-EN2T modules

ndash One 1756-RMCx cable

One 1757-SRM module per chassis that supports the followingndash One 1756-L61 1756-L62 1756-L63 1756-L64 controller

ndash Maximum of seven communication modules which can be 1756-CNB series D or E 1756-CNBR series D or E 1756-ENBT and 1756-EWEB modules

ndash One 1757-SRCx cable

30 Publication 1756-SG001P-EN-P - May 2011

Accessories - Controllers

Memory Cards

Memory cards offer nonvolatile memory to permanently store a user program and tag data on a controller The 1756-L7x ControlLogix controller comes with 1784-SD1 Secure Digital (SD) card already installed The 1756-L6x controllers support optional CompactFlash cards that you purchase separately The memory card installs in a socket on the controller Through RSLogix 5000 software you can manually trigger the controller to save to or load from nonvolatile memory or configure the controller to load from nonvolatile memory on powerup

The GuardLogix controller does not support user program storage or retrieval by using a CompactFlash card

1756 Energy Storage Modules

Instead of a battery the 1756-L7x controller ships with a 1756-ESMCAP energy storage module (ESM) already installed

Attribute 1784-CF64 1784-CF128 1784-SD1 1784-SD2

Memory 64 MB 128 MB 1 GB 2 GB

Supported controllers 1756-L6x 1756-L7x

Weight approx 142 g (05 oz) 176 g (0062 oz)

Cat No Description

1756-ESMCAP Capacitor-based energy-storage module Comes with the controller

1756-EMNSE ESM without WallClockTime backup power Additionally you can use this ESM with a 1756-L73 (8 MB) or smaller memory-sized controller only

Use this ESM if your application requires that the installed ESM deplete its residual energy to 40 microJoule or less before transporting it into or out of your application

1756-ESMNRM Energy-storage module that secures the controller by preventing the USB connection and SD card useThis ESM provides your application an enhanced degree of security

Publication 1756-SG001P-EN-P - May 2011 31

1756 ControlLogix Batteries

Each 1756-L6x controller ships with a battery With a memory card installed the controller can be used without a battery If you do not use a battery current tag data will be at the state it was when the memory card was saved

ControlLogix Chassis The ControlLogix system is a modular system that requires a 1756 IO chassis Place any module into any slot The backplane provides a high-speed communication path between modules

All of the chassis are designed for horizontal-only back-panel mounting The chassis are available in these configurations

Standard chassis ControlLogix-XT chassis

For detailed specifications see 1756 ControlLogix Chassis Specifications Specifications publication 1756-TD006

Features - Chassis

Slot guides and snap-in retention for easy and secure module fit for any type of 1756 module

Direct mounting accommodates any 1756 power supply

Attribute 1756-BA1 1756-BA2 1756-BATM(1) 1756-BATA

Description Lithium battery (059 g) Lithium battery (059 g) Externally mounted battery assembly

Replacement lithium battery for 1756-BATM (5 g max lithium per each D cell contains 2 D cells)

ControlLogix controllers 1756-L61 1756-L62 1756-L63 series A

1756-L61 1756-L62 1756-L63 series B1756-L64 1756-L65

1756-L61 1756-L62 1756-L63 series A

1756-BATM battery module

GuardLogix controllers mdash 1756-L61S 1756-L62S 1756-L63S

mdash mdash

ControlLogix-XT controllers

mdash 1756-L63XT mdash mdash

(1) The 1756-BATM externally mounted battery assembly is highly recommended for use with all series A 1756-L6x controllers and provides longer battery life than the 1756-BA1 battery The 1756-BATM includes one 1756-BATA lithium battery assembly and a 1 m (328 ft) cable to connect housing to controller

32 Publication 1756-SG001P-EN-P - May 2011

Standard Chassis

The chassis backplane provides a high-speed communication path between modules and distributes power to each of the modules within the chassis

ControlLogix-XT Chassis

The ControlLogix-XT chassis support extreme temperature environments

Accessories - Chassis

Use a slot filler module to fill empty slots

Cat No Description Slots

1756-A4 ControlLogix standard chassis 4

1756-A7 7

1756-A10 10

1756-A13 13

1756-A17 17

Cat No Description Slots Temperature Range

1756-A4LXT ControlLogix-XT chassis 4 -2560 degC (-13140 degF)

1756-A5XT 5 -2570 degC (-13158 degF)

1756-A7LXT 7 -2560 degC (-13140 degF)

Cat No Description

1756-N2 Slot filler module for empty slots in standard ControlLogix chassis

1756-N2XT Slot filler module for empty slots in ControlLogix-XT chassis

Publication 1756-SG001P-EN-P - May 2011 33

ControlLogix Power Supplies

ControlLogix power supplies are used with the 1756 chassis to provide 12V 33V 5V and 24V DC power directly to the chassis backplane Select from these configurations

Standard power Redundant power ControlLogix-XT power

For detailed specifications see 1756 ControlLogix Power Supplies Specifications publication 1756-TD005

Standard Power Supplies

You mount a standard power supply directly on the left end of the chassis where it plugs directly into the backplane

ControlLogix-XT Power Supplies

The ControlLogix-XT power supplies support extreme temperature environments

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA72 ControlLogix standard AC 120V220V AC 85hellip265V AC Standard series A and series B

1756-PA75 120V220V AC 85hellip265V AC Standard series B

1756-PB72 ControlLogix standard DC 24V DC 18hellip32V DC Standard series A and series B

1756-PB75 24V DC 1832V DC Standard series B

1756-PC75 48V DC 30hellip60V DC Standard series B

1756-PH75 125V DC 90hellip143V DC Standard series B

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PAXT ControlLogix-XT AC power supply 85265V AC 120240V AC XT

1756-PBXT ControlLogix-XT DC power supply 24V DC 18hellip32V DC XT

34 Publication 1756-SG001P-EN-P - May 2011

Redundant Power Supplies

To build a redundant power supply system you need the following

Two redundant power supplies (both 1756-PA75R or 1756-PB75R) One 1756-PSCA2 chassis adapter module Two 1756-CPR2 cables to connect the power supplies to the

1756-PSCA2 chassis adapter module (091 m (3 ft) length) User-supplied annunciator wiring to connect the power supplies to the

input modules as needed

The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Accessories - Redundant Power Supplies

Visualization Products Visualization products together with Logix for control and NetLinx architecture for communication make up the Rockwell Automation Integrated Architecture strategy The visualization strategy combines Rockwell Automation expertise in Allen-Bradley electronic operator interface and industrialized personal computer hardware with Rockwell Software supervisory control software Current visualization products include the following

FactoryTalk View software PanelView Plus operator interface PanelView Plus CE operator interface Industrial computers and monitors

For more information see the Operator Interface catalog pages at httpwwwabcomenepubcatalogs1276221813761239781

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA75R ControlLogix redundant 120V220V AC 85hellip265V AC Standard series B

1756-PB75R 24V DC 192hellip32V DC Standard series B

Cat No Description Specifications

1756-PSCA2 Chassis adapter module Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Mounts directly to left side of 1756 chassis

1756-CPR2 Chassis adapter cable Connects redundant power supply to 1756-PCSA2 chassis adapter Length091 m (3 ft)

Publication 1756-SG001P-EN-P - May 2011 35

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA ltFEFF005500740069006c006900730065007a00200063006500730020006f007000740069006f006e00730020006100660069006e00200064006500200063007200e900650072002000640065007300200064006f00630075006d0065006e00740073002000410064006f00620065002000500044004600200070006f007500720020006400650073002000e90070007200650075007600650073002000650074002000640065007300200069006d007000720065007300730069006f006e00730020006400650020006800610075007400650020007100750061006c0069007400e90020007300750072002000640065007300200069006d007000720069006d0061006e0074006500730020006400650020006200750072006500610075002e0020004c0065007300200064006f00630075006d0065006e00740073002000500044004600200063007200e900e90073002000700065007500760065006e0074002000ea0074007200650020006f007500760065007200740073002000640061006e00730020004100630072006f006200610074002c002000610069006e00730069002000710075002700410064006f00620065002000520065006100640065007200200035002e0030002000650074002000760065007200730069006f006e007300200075006c007400e90072006900650075007200650073002egt ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO ltFEFF004b00e40079007400e40020006e00e40069007400e4002000610073006500740075006b007300690061002c0020006b0075006e0020006c0075006f0074002000410064006f0062006500200050004400460020002d0064006f006b0075006d0065006e007400740065006a00610020006c0061006100640075006b006100730074006100200074007900f6007000f60079007400e400740075006c006f0073007400750073007400610020006a00610020007600650064006f007300740075007300740061002000760061007200740065006e002e00200020004c0075006f0064007500740020005000440046002d0064006f006b0075006d0065006e00740069007400200076006f0069006400610061006e0020006100760061007400610020004100630072006f0062006100740069006c006c00610020006a0061002000410064006f00620065002000520065006100640065007200200035002e0030003a006c006c00610020006a006100200075007500640065006d006d0069006c006c0061002egt SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

DC Digital Input Modules

DC Digital Output Modules

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

1756-IB16 16 inputs(8 pointsgroup)

1224V DC sink 10312V DC 1756-TBNH1756-TBSH

1756-IB16D 16 diagnostic inputs(4 pointsgroup)

1224V DC sink 1030V DC 1756-TBCH1756-TBS6H

1756-IB16I 16 individually isolated inputs 1224V DC sinksource 1030V DC 1756-TBCH1756-TBS6H

1756-IB16ISOE 16 individually isolated sequence of events inputs

2448V DC sinksource 1055V DC 1756-TBCH1756-TBS6H

1756-IB32 32 inputs(16 pointsgroup)

1224V DC sink 10312V DC 1756-TBCH1756-TBS6H

1756-IC16 16 inputs(8 pointsgroup)

48V DC sink 3055V DC 60 degC (140 degC)3060V DC 55 degC (131 degC)

1756-TBNH1756-TBSH

1756-IG16 16 inputs(8 pointsgroup)

5V DC TTL source (Low=True)

4555V DC 1756-TBNH1756-TBSH

1756-IH16I 16 individually isolated inputs 125V DC sinksource 90146V DC 1756-TBCH1756-TBS6H

1756-IH16ISOE 16 individually isolated sequence of events inputs

125V DC sinksource 90140V DC 1756-TBCH1756-TBS6H

1756-IV16 16 inputs(8 pointsgroup)

1224V DC source 1030V DC 1756-TBNH1756-TBSH

1756-IV32 32 inputs(16 pointsgroup)

1224V DC source 1030V DC 1756-TBCH1756-TBS6H

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

1756-OB8 8 outputs 1224V DC source 1030V DC 1756-TBNH1756-TBSH

1756-OB8EI 8 electronically fused individually isolated outputs

1224V DC source 1030V DC 1756-TBCH1756-TBS6H

1756-OB8I 8 individually isolated outputs 1224V DC source 1030V DC 1756-TBCH1756-TBS6H

1756-OB16D 16 diagnostic outputs(8 pointsgroup)

24V DC source 19230V DC 1756-TBCH1756-TBS6H

1756-OB16E 16 electronically fused outputs(8 pointsgroup)

1224V DC source 10312V DC 1756-TBNH1756-TBSH

1756-OB16I 16 individually isolated outputs

1224V DC sinksource 1030V DC 1756-TBCH1756-TBS6H

1756-OB16IS 16 individually isolated outputs8 scheduled outputs

1224V DC sinksource 1030V DC 1756-TBCH1756-TBS6H

1756-OB32 32 outputs(16 pointsgroup)

1224V DC source 10312V DC 1756-TBCH1756-TBS6H

Publication 1756-SG001P-EN-P - May 2011 9

Contact Output Modules

Analog Input Modules

1756-OC8 8 outputs(4 pointsgroup)

48V DC source 3060V DC 1756-TBNH1756-TBSH

1756-OG16 16 (8 pointsgroup) 5V DC TTL source (Low=True)

4555V DC 1756-TBNH1756-TBSH

1756-OH8I 8 outputsindividually isolated

120V DC 90146V DC 1756-TBCH1756-TBS6H

1756-OV16E 16 electronically fused outputs(8 pointsgroup)

1224V DC sink 1030V DC 1756-TBNH1756-TBSH

1756-OV32E 32 electronically fused outputs (16 pointsgroup)

1224V DC sink 1030V DC 1756-TBCH1756-TBS6H

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

Cat No InputsOutputs Operating Voltage Range Removable Terminal Block

1756-OW16I 16 normally open individually isolated outputs 5150V DC10265V AC

1756-TBCH1756-TBS6H

1756-OX8I 8 normally open8 normally closed individually isolated outputs(2 pointsgroup)

5150V DC10265V AC

1756-TBCH1756-TBS6H

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-IF6CIS 6 individually isolated inputs current sourcing

0hellip21 mA 16 bits034 Abit

1756-TBNH1756-TBSH

1756-IF6I 6 individually isolated inputs plusmn105V0hellip105V0hellip525V0hellip21 mA

16 bits105V 343 Vbit0hellip105V 171 Vbit0hellip525V 86 Vbit0hellip21 mA 034 Abit

1756-TBNH1756-TBSH

1756-IF8 8 single-ended inputs4 differential inputs2 high-speed differential inputs

plusmn1025V01025V05125V0hellip205 mA

plusmn1025V 320 Vcnt (15 bits plus sign bipolar)0hellip1025V 160 Vcnt (16 bits)0hellip5125V 80 V cnt (16 bits)0hellip205mA 032 Acnt (16 bits)

1756-TBCH1756-TBS6H

10 Publication 1756-SG001P-EN-P - May 2011

Analog RTD and Thermocouple Modules

Analog Output Modules

1756-IF8H 8 differential voltage or current inputs HART interface

plusmn10V05V1hellip5V010V0hellip20 mA4hellip20 mA

16hellip21 bits 1756-TBCH1756-TBS6H

1756-IF16 16 single-ended inputs8 differential or 4 differential (high speed) inputs

plusmn105V0hellip105V0hellip525V0hellip21 mA

16 bits105V 343 Vbit0hellip105V 171 Vbit0hellip525V 86 Vbit0hellip21 mA 034 Abit

1756-TBCH1756-TBS6H

1756-IF16H 16 differential current inputs HART interface

0hellip20 mA4hellip20 mA

16hellip21 bits 1756-TBCH1756-TBS6H

Cat No InputsOutputs Range Resolution Removable Terminal Block

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-IR6I 6 individually isolated RTD inputs 1hellip487 2hellip1000 4hellip20008hellip4020

16 bits1hellip487 77 mbit2hellip1000 15 mbit4hellip2000 30 mbit8hellip4020 60 mbit

1756-TBNH1756-TBSH

1756-IT6I 6 individually isolated thermocouple inputs1 CJC

-12hellip78 mV-12hellip30 mV

16 bits-1278 mV 14 Vbit-1230 mV 07 Vbit

1756-TBNH1756-TBSH

1756-IT6I2 6 individually isolated thermocouple inputs2 CJC

-12hellip78 mV (14 V per bit)-12hellip30 mV (07 V per bit ndash high resolution range)

16 bits-1278 mV 14 Vbit-1230 mV 07 Vbit

1756-TBNH1756-TBSH

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-OF4 4 voltage or current outputs plusmn104V0hellip21 mA

Voltage15 bits across 105V 320 VbitCurrent15 bits across 21mA 650 nAbit

1756-TBNH1756-TBSH

1756-OF6CI 6 individually isolated outputs current

0hellip21 mA 13 bits across 21 mA (27 A) 1756-TBNH1756-TBSH

1756-OF6VI 6 individually isolated outputs voltage

plusmn105V 14 bits across 21V (13 mV)(13 bits across 105V +sign bit)

1756-TBNH1756-TBSH

1756-OF8 8 voltage or current outputs plusmn104V0hellip21 mA

15 bits across 21 mA - 650 nAbit15 bits across 104V - 320 Vbit

1756-TBNH1756-TBSH

1756-OF8H 8 voltage or current outputs HART interface

plusmn104V0hellip20 mA4hellip20 mA

15hellip16 bits 1756-TBNH1756-TBSH

Publication 1756-SG001P-EN-P - May 2011 11

Analog Combination Input and Output Module

Specialty IO Modules

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-IF4FXOF2F 4 high-speed sub-millisecond differential inputs2 high-speed voltage or current outputs

Inputplusmn105V0hellip105V0hellip525V0hellip21 mAOutputplusmn104V0hellip21 mA

InputApprox 14 bits across plusmn10V DC (21V total)plusmn10V 13 mVbit 14-bit effective0hellip105V 13 mVbit 13-bit effective0hellip525V 13 mVbit 12-bit effectiveApprox 12 bits across 21 mA0hellip21 mA 525 AbitOutput13 bits across 21 mA = 28 Abit14 bits across 218V = 13 mVbit

1756-TBCH1756-TBS6H

Cat No InputsOutputs Description Removable Terminal Block

1756-CFM 4 inputs (2 per channel) 2 outputs current sourcing

Configurable flowmeter module2 Flowmeter (F) inputs used for all modes2 Gate inputs used in Totalizer mode for proverstore count

1756-TBNH1756-TBSH

1756-HSC 2 counters each with 3 inputs (A B Z for gatereset)4 outputs (2 pointsgroup)

High-speed counter module5V operation 45hellip55V DC1224V operation 10hellip312V DC

1756-TBCH1756-TBS6H

1756-PLS Left section 2 groups of 4 outputs and 4 inputs eachCenter section resolver interface and IO controlRight section 2 groups of 4 outputs and 4 inputs each

Programmable limit switch module Requires 3 RTBs 1756-TBNH or 1756-TBSH

12 Publication 1756-SG001P-EN-P - May 2011

HART Smart Instrumentation

HART (Highway Addressable Remote Transmitter) is an open protocol designed to connect analog devices For HART connectivity select from products available from Rockwell Automation and our Encompass partners

Typical HART Configuration

HART Interfaces

Accessories - IO Modules

1756 Removable Terminal Blocks

Removable terminal blocks (RTBs) provide a flexible interconnection between your plant wiring and 1756 IO modules The RTB plugs into the front of the IO module The type of module determines which RTB you need You can choose screw-clamp or spring-clamp RTBs

RTBs are not shipped with IO modules You must order them separately The standard housing on the front of the wiring arm is not deep enough for 25 mm2

HART Devices

ControlLogix Controller with 1756-IF8H or 1756-OF8H module

If your application has Select Description

Analog and HART connectivity in one moduleNo external hardware required to access HART signalHART commands can be transmitted as unscheduled messagesSupports asset management software to HART device

1756-IF8H1756-IF16H1756-OF8H

Rockwell Automation analog IO modules

Data acquisition or control application with slow update requirements (such as a tank farm)No external hardware required to access HART signalDoes not connect directly to asset management software

MVI56-HART Prosoft interface

Analog and HART in one moduleInstrumentation in hazardous locations (FLEX Ex modules)HART commands can be transmitted as unscheduled messagesDirectly connects asset management software to HART devices

1794 FLEX IO1797 FLEX Ex IO

There are specific FLEX IO and FLEX Ex modules designed for HART systems These catalog numbers end in an H such as 1797-IE8H

Publication 1756-SG001P-EN-P - May 2011 13

(14 AWG) wiring If you plan to use 25 mm2 (14 AWG) wiring also order the extended housing

Wiring Systems

As an alternative to buying RTBs and connecting the wires yourself you can buy a wiring system of the following

Interface modules (IFMs) that provide the output terminal blocks for digital IO modules Use the pre-wired cables that match the IO module to the IFM

Analog interface modules (AIFMs) that provide the output terminal blocks for analog IO modules Use the pre-wired cables that match the IO module to the AIFM

IO module-ready cables One end of the cable assembly is an RTB that plugs into the front of the IO module The other end has individually color-coded conductors that connect to a standard terminal block

Attribute 1756-TBNH 1756-TBSH 1756-TBCH 1756-TBS6H 1756-TBE

Description 20-position NEMA screw-clamp removable block

20-pin spring-clamp removable terminal block with standard housing

36-pin cage-clamp removable terminal block with standard housing

36-pin spring-clamp removable terminal block with standard housing

Extended depth terminal block housing

Screw torque 08hellip1 Nbullm7hellip9 lbbullin

04 Nbullm44 lbbullin

mdash

Screwdriver width 8 mm (516 in) max

IO Module

RTBPre-wired Cable

Factory-wired

Interface Module (IFM)

Field Wiring

14 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Integrated Motion

The Logix architecture supports motion control components that work in a wide variety of machine architectures

Integrated motion on EtherNetIP supports a connection to Ethernet drives

The Kinetix integrated-motion solution uses a SERCOS interface module to perform multi-axis synchronized motion

Logix integrated motion supports the analog family of servo modules for controlling drivesactuators

Networked motion provides the ability to connect via the DeviceNet network to a single axis drive to perform point-to-point indexing

For detailed specifications on motion interface modules see 1756 ControlLogix Integrated Motion Specifications publication 1756-TD004

For more information see these publications

Motion Analyzer CD to size your motion application and to make final component selection Download the software from httpwwwabcommotionsoftwareanalyzerhtml

Kinetix Motion Control Selection Guide publication GMC-SG001 to verify drive motor and accessory specifications

Integrated Motion on an EtherNetIP Network

Product Consideration

Drive that supports EtherNetIP connections Unlimited velocity torque and Vhz configured drives Kinetix 6500 drives PowerFlex 755 drives

ControlLogix controller As many as 100 drives per controller

ControlLogix EtherNetIP communication module 1hellip8 position configured drives with 1756-EN2TR module 1hellip255 position configured drives with 1756-EN3TR module

Publication 1756-SG001P-EN-P - May 2011 15

SERCOS Interface Modules

The SERCOS interface modules can connect to these servo drives

2093 Kinetix 2000 multi-axis servo drive 2094 Kinetix 6000 multi-axis servo drive 2099 Kinetix 7000 high-power servo drive 2098 Ultra3000 SERCOS servo drive

ControlLogix Controller

PanelView Plus Terminal

Workstations

POINT IO ModulesDrive with EtherNetIP Connection

Cat No Description Number of Axis

1756-M16SE Rockwell Automation SERCOS interface modules 16

1756-M08SE 8

1756-M03SE 3

1756-M08SEG SERCOS interface drives that are Extended Pack Profile compliant 8

16 Publication 1756-SG001P-EN-P - May 2011

Analog Motion Interface Modules

RSLogix 5000 Software1756-MxxSE Module

ControlLogix Controller

Three-phase Input Power

Line Interface Module

Integrated Axis Module

Motor Motor Feedback

Axis Modules

Slot Filler Module

Shunt Module

SERCOS Fiber-optic RingKinetix 6000 Multi-axis Servo Drive

Cat No Description Number of Axis

1756-M02AE Analog servo interface drives with quadrature feedback 2

1756-HYD02 Analog hydraulic servo interface drives LDT feedback 2

1756-M02AS Analog servo interface drives with SSI feedback 2

Publication 1756-SG001P-EN-P - May 2011 17

ControlLogix Communication Modules

Separate communication modules are available for different networks Install multiple communication modules into the ControlLogix backplane to bridge or route control and information data between different networks You can route a message through a maximum of four chassis (eight communication hops) You do not need a ControlLogix controller in the chassis

For detailed specifications see 1756 ControlLogix Network Specifications publication 1756-TD003

Application Network Page

Plant management (material handling) Configuration data collection and control on a single high-speed network Time-critical applications with no established schedule Inclusion of commercial technologies (such as video over IP) InternetIntranet connection Integrated CIP motion and safety

EtherNetIP network 19

High-speed transfer of time-critical data between controllers and IO devices Deterministic and repeatable data delivery Media redundancy Intrinsic safety Redundant controller systems

ControlNet network 20

Connections of low-level devices directly to plant floor controllers without interfacing them through IO modules

Data sent as needed More diagnostics for improved data collection and fault detection Less wiring and reduced start-up time than a traditional hard-wired system

DeviceNet network 21

Plant-wide and cell-level data sharing with program maintenance Data sent regularly Transfer of information between controllers

Data Highway Plus network 23

Connections between controllers and IO adapters Data sent regularly Distributed control so that each controller has its own IO and communicates with a

supervisory controller

Remote IO network 23

Fieldbus transmitters and actuators Closed-loop control Process automation

Foundation Fieldbus network 25

18 Publication 1756-SG001P-EN-P - May 2011

EtherNetIP Communication Modules

The Ethernet Industrial (EtherNetIP) network protocol is an open industrial-networking standard that supports both real-time IO messaging and message exchange The EtherNetIP network uses off-the-shelf Ethernet communication chips and physical media

Accessories - EtherNetIP Network

Cat No Description Media Communication Rate

CIP Motion Axes max

TCPIP Connections

Logix Connections

1756-EN2F EtherNetIP bridge fiber Fiber 100 Mbps 8 128 256

1756-EN2T EtherNetIP bridge copper Copper 10100 Mbps 8 128 256

1756-EN2TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 8 128 256

1756-EN3TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 255 128 256

1756-ENBT EtherNetIP bridge copper Copper 10100 Mbps mdash 64 128

1756-EWEB Ethernet web server module Copper 10100 Mbps mdash 64 128

1756-EN2TXT ControlLogix-XT extended temperature EtherNetIP bridge copper for extreme environments

Copper 10100 Mbps 8 128 256

Cat No Description Specifications

1585J-M8PBJM-x Ethernet RJ45 patchcordx = 2 (2 m) 5 (5 m) or 10 (10 m)

8-conductor Teal Riser PVC Cable (Flex Rated cable also available)

1585J-M8CC-H RJ45 insulation displacement connector (IDC) 01280325 mm2 (26hellip22 AWG) Cat 6 IDC no tool required

1585J-M8CC-C RJ45 crimp connector with boot qty = 50 pieces 01280205 mm2 (26hellip24 AWG Cat 5e requires crimp tool for assembly

1585A-Jcrimp Crimp tool mdash

9300-RADES Remote access dial-in kit 56 Kbps modem connection to devices on an Ethernet network includes pre-configured modem communication module DIN rail mounting hardware associated cables

Publication 1756-SG001P-EN-P - May 2011 19

Example Configuration - EtherNetIP Network

ControlNet Communication ModulesThe ControlNet network combines the functionality of an IO network and a peer-to-peer network providing high-speed performance The ControlNet network provides deterministic repeatable transfers of critical control data

FirewallRouter

Stratix Switch

Stratix Switch

Stratix Switch

Powermonitor 3000PowerFlex 70

Ethernet PLC-5

MicroLogix

Ethernet SLC 500

1756 IO

1794 IO

1761-NET-ENI

ControlNet

DeviceNet

1734 IO

RSLinxPanelView Plus

1769-L35E CompactLogix

Cat No Description Communication Rate

Logix Connections Number of Nodes

1756-CN2B ControlNet bridge standard media 5 Mbps 128(1) 99

1756-CN2RB ControlNet bridge redundant media 5 Mbps 128(1) 99

1756-CNB ControlNet bridge standard media 5 Mbps 64(2) 99

1756-CNBR ControlNet bridge redundant media 5 Mbps 64(2) 99

1756-CN2RXT ControlLogix-XT extended temperature ControlNet bridge redundant media

5 Mbps 128(1) 99

(1) 128 connections are available for standard use An additional three connections are reserved for redundant control

(2) Recommend using only 4048 Logix connections for IO

20 Publication 1756-SG001P-EN-P - May 2011

Example Configuration - ControlNet Network

Example Configuration - Redundant ControlNet Media

For information on ControlNet media see ControlNet Media System Components List AG-PA002

DeviceNet Communication Module

The DeviceNet network provides connections between simple industrial devices (such as sensors and actuators) and higher-level devices (such as controllers and computers)

1784-U2CNPanelView Plus

1788-CN2DN

DeviceNetPowerFlex 700SPLC-540CControlLogix

Redundant Media

ControlLogix1756-CNBR

ControlNet Node

ControlNet Node

Cat No Description Communication Rate Number of Nodes

1756-DNB DeviceNet bridge 125 Kbps (500 m max)250 Kbps (250 m max)500 Kbps (100 m max)

64

Publication 1756-SG001P-EN-P - May 2011 21

Example Configuration - DeviceNet Network

Accessories - DeviceNet Network

PLC-51771-SDN ControlLogix

1756-DNB

Ultra3000

PanelView Plus1784-U2DN

Ultra5000

IO

Motor starter

PowerFlex AC

Sensor Pushbuttons

LightsBar Code Scanner

Cat No Description

KwikLink Lite flat media KwikLink Lite flat media is a newer ODVA-approved solution for wiring DeviceNet networks Drop-lines for connecting nodes are added by using the KwikLink Lite two-piece connectors This cable system supports the intermixing of DeviceNet cable types (thin-round with flat) All of the KwikLink Lite connectors provide insulation displacement technology with reduced assembly time

KwikLink flat media The KwikLink flat media system provides a modular cabling method with its flat 4-wire cable and insulation displacement connectors (IDCs) The KwikLink system allows nodes to be added to the network without severing the trunkline Cutting or stripping of the trunkline is eliminated as is the need for predetermined cable lengths

Round media Round trunk cable is available in bulk spools or as pre-molded cordsets or patchcords in varying lengths A wide variety of rugged durable DeviceNet components is available for use in round trunk systems Stainless steel versions of round cable system components are also available Thick-trunk round media systems use thick cable for maximum DeviceNet trunk line length Round media thin-trunk systems use thin cable to reduce maximum trunk line distances with a more

compact and cost-effective installation for some applications Thin-cable outer jacket material is TPE for additional chemical resistance

22 Publication 1756-SG001P-EN-P - May 2011

Data Highway Plus and Remote IO Communication Modules

The Data Highway Plus network supports messaging between devices The remote IO link connects to remote IO chassis and other intelligent devices

The 1756-DHRIO module supports messaging between devices on DH+ networks The remote IO functionality enables the module to act as a scanner for transferring digital and block-transfer data to and from remote IO devices

The 1756-RIO module can act as a scanner or adapter on a remote IO network In addition to digital and block-transfer data the 1756-RIO module transfers analog and specialty data without message instructions

Cat No Description Communication Rate DH+ Connections RIO Connections Maximum Recommended Logix Connections

1756-DHRIO Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

1756-RIO Remote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

mdash Remote IO scanner or adapter32 physical racks (076) any combination of rack size and block transfers

10 scheduled IO

1756-DHRIOXT ControlLogix-XT extended temperature Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

Publication 1756-SG001P-EN-P - May 2011 23

Example Configuration - DH+ Network

Example Configuration - Remote IO Network

Accessories - DH+ and Remote IO Networks

PanelView Plus

PLC-5 1784-U2DHPRSLogix 5000

ControlLogix1756-DHRIO

SLC 504

PanelView PlusPLC-5

1791 IO1794 IO

1756-RIO as a Remote IO Adapter

1756-DHRIO as a Remote IO Scanner

Cat No Description Specifications

1770-CD Cable to connect communication module to DH+ network Belden 9463 twinaxial

9300-RADKIT Remote access dial-in kit 56 Kbps modem connection to devices on a DH+ network includes pre-configured modem communication module DIN rail mounting hardware associated cables

24 Publication 1756-SG001P-EN-P - May 2011

FOUNDATION Fieldbus Linking Devices

The FOUNDATION Fieldbus protocol is a network designed for distributed control of process applications

Example Configuration - Bridge to EtherNetIP Network

Cat No Description Communication Rate Number of H1 Ports

Devices per H1 Link

Devices per Linking Device

1757FFLD2 FOUNDATION Fieldbus bridge to an Ethernet network

FOUNDATION Fieldbus 3125 KbpsEtherNetIP 10100 Mbps

2 16(8hellip10 recommended)

32

1757-FFLD4 4 64

1757-FFLDC2 FOUNDATION Fieldbus bridge to a ControlNet network

FOUNDATION Fieldbus 3125 KbpsControlNet 5 Mbps

2 16(8hellip10 recommended)

32

1757-FFLDC4 4 64

FactoryTalk View SERSFieldbusRSLogix 5000

1757-FFLD4

H1(1)

H1(2)H1(3)H1(4)

HSEIP

Publication 1756-SG001P-EN-P - May 2011 25

Example Configuration - Bridge to ControlNet Network

Other Connectivity Options

ControlLogix RedundancyFactoryTalk View SERSFieldbusRSLogix 5000

ControlNet Redundant Media

1757-FFLDC2

FF H1

EtherNetIP

Option Consideration

USB connection The 1756-L7x controller has a USB port in place of the serial port If your application requires RS-232 functionality see the many Encompass partners at httpwwwrockwellautomationcomencompass

Serial connection The serial port on the 1756-L6x controller is compatible with RS-232 serial communication The serial port supports the DF1 protocol to communicate with other devices on the serial linkTo use Logix5000 controllers on Modbus you connect through the serial port and execute a specific ladder logic routine The controller project is available with RSLogix 5000 Enterprise programming software For more information see Using Logix5000 Controllers as Masters or Slaves on Modbus Application Solution publication CIG-AP129

DH-485 network The controller serial port is compatible with DH-485 communication The DH-485 connection does support remote programming and monitoring via RSLogix 5000 softwareOr add a DH-485 communication bridge module (cat no 1756-DH485)

SynchLink network The SynchLink communication module (1756-SYNCH) provides time synchronization and data broadcasting capabilities for distributed motion and coordinated drive control The module connects a ControlLogix chassis to a SynchLink fiber-optic communication link

26 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Controllers The ControlLogix controller provides a scalable controller solution that is capable of addressing a large amount of IO points

The controller can be placed into any slot of a ControlLogix chassis and multiple controllers can be installed in the same chassis Multiple controllers in the same chassis communicate with each other over the backplane (just as controllers can communicate over networks) but operate independently

ControlLogix controllers can monitor and control IO across the ControlLogix backplane as well as over IO links ControlLogix controllers can communicate over EtherNetIP ControlNet DeviceNet DH+ Remote IO and RS-232-C (DF1DH-485 protocol) networks and many third party process and device networks To provide communication for a ControlLogix controller install the appropriate communication interface module into the chassis

For detailed specifications see 1756 ControlLogix Controllers Specifications publication 1756-TD001

Cat No Description User Memory

1756-L72 ControlLogix controller 1 built-in USB port 4 MB

1756-L73 8 MB

1756-L74 16 MB

1756-L75 32 MB

1756-L61 ControlLogix controller 1 built-in RS-232 port 2 MB

1756-L62 4 MB

1756-L63 8 MB

1756-L64 16 MB

1756-L65 32 MB

1756-L61S GuardLogix safety controller 2 MB standard1 MB safety

1756-L62S 4 MB standard1 MB safety

1756-L63S 8 MB standard375 MB safety

1756-LSP GuardLogix safety partner (one is required for each GuardLogix controller) mdash

1756-L63XT ControlLogix-XT controller extreme environment 8 MB

IMPORTANT Scan time for a project loaded in a 1756-L64 or 1756-L65 controller may be slower than for the same project loaded in one of the other 1756-L6x controllers See the Logix5000 Controllers Instruction Execution Time and Memory Use Reference Manual publication 1756-RM087 for instruction execution times

Publication 1756-SG001P-EN-P - May 2011 27

Standard ControlLogix Controllers

The ControlLogix controller is part of the Logix5000 family of controllers A ControlLogix system includes the following

The ControlLogix controller available in different combinations of user memory

RSLogix 5000 programming software 1756 ControlLogix IO modules that reside in a 1756 chassis Separate communication modules for network communication

Features - Standard ControlLogix Controllers

Feature 1756-L61 1756-L62 1756-L63 1756-L64 1756-L65

1756-L72 1756-L73 1756-L74 1756-L75

Controller tasks 32 tasks 100 programstask Event tasks all event triggers

Built-in communication ports 1 port RS-232 serial 1 port USB

Communication options EtherNetIP ControlNet DeviceNet Data Highway Plus Remote IO SynchLink Third-party process and device networks

Built-in port Serial USB

Controller connections supported max 250 500

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Full support

Integrated motion EtherNetIP connection SERCOS interface Analog options (encoder input LDT input SSI input)

Programming languages Relay ladder Structured text Function block SFC

28 Publication 1756-SG001P-EN-P - May 2011

GuardLogix Controllers

A GuardLogix controller is a ControlLogix controller that also provides safety control The GuardLogix system is a dual controller solutionmdashyou must use a 1756-L6xS primary controller and a 1756-LSP safety partner to achieve SIL 3CAT 4

During development safety and standard have the same rules multiple programmers online editing and forcing are all allowed Once the project is tested and ready for final validation you set the Safety Task to a SIL 3 integrity level which is then enforced by the GuardLogix controller When safety memory is locked and protected the safety logic cant be modified and all safety functions operate with SIL 3 integrity On the standard side of the GuardLogix controller all functions operate like a regular Logix controller

Use Guard IO modules for field device connectivity on Ethernet or DeviceNet networks and for safety interlocking between GuardLogix controllers use Ethernet or ControlNet networks Multiple GuardLogix controllers can share safety data for zone to zone interlocking or a single GuardLogix controller can use remote distributed safety IO between different cellsareas

In addition to the standard features of a ControlLogix controller the GuardLogix controller has these safety-related features

Application Description

SIL 1 2 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508 and applications up to and including PLeCat4 according to ISO 13849-1 For more information see GuardLogix Controllers Systems Safety Reference Manual publication 1756-RM093 GuardLogix Controllers User Manual publication 1756-UM020 GuardLogix Safety Application Instruction Set Reference Manual publication 1756-RM095

Features - GuardLogix Controllers

Feature 1756-L61S 1756-L62S 1756-L63S 1756-LSP

Safety communication options Standard and safety EtherNetIP ControlNet DeviceNet

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Not supported

Programming languages Relay ladder

Publication 1756-SG001P-EN-P - May 2011 29

ControlLogix-XT Controllers

The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh corrosive environments

When used with FLEX IO-XT products the ControlLogix-XT system can withstand temperatures range from -2070 C (-4158 F)

When used independently the ControlLogix-XT system can withstand temperature ranges from -2570 C (-13158 F)

Redundant ControlLogix Controllers

The ControlLogix controller supports controller redundancy In a redundant controller system you need these components

Two 1756 chassis each with the following the same ndash Number of slots

ndash Modules in the same slots

ndash Redundancy firmware revisions in each module

ndash Two additional ControlNet nodes outside the redundant chassis pair

You need one of these redundancy modules

One 1756-RM module per chassis that supports the followingndash Two 1756-L61 1756-L62 1761-L63 controllers or one 1756-L64

controller

ndash Maximum of seven communication modules which can be 1756-CN2 series B 1756-CN2R series B and 1756-EN2T modules

ndash One 1756-RMCx cable

One 1757-SRM module per chassis that supports the followingndash One 1756-L61 1756-L62 1756-L63 1756-L64 controller

ndash Maximum of seven communication modules which can be 1756-CNB series D or E 1756-CNBR series D or E 1756-ENBT and 1756-EWEB modules

ndash One 1757-SRCx cable

30 Publication 1756-SG001P-EN-P - May 2011

Accessories - Controllers

Memory Cards

Memory cards offer nonvolatile memory to permanently store a user program and tag data on a controller The 1756-L7x ControlLogix controller comes with 1784-SD1 Secure Digital (SD) card already installed The 1756-L6x controllers support optional CompactFlash cards that you purchase separately The memory card installs in a socket on the controller Through RSLogix 5000 software you can manually trigger the controller to save to or load from nonvolatile memory or configure the controller to load from nonvolatile memory on powerup

The GuardLogix controller does not support user program storage or retrieval by using a CompactFlash card

1756 Energy Storage Modules

Instead of a battery the 1756-L7x controller ships with a 1756-ESMCAP energy storage module (ESM) already installed

Attribute 1784-CF64 1784-CF128 1784-SD1 1784-SD2

Memory 64 MB 128 MB 1 GB 2 GB

Supported controllers 1756-L6x 1756-L7x

Weight approx 142 g (05 oz) 176 g (0062 oz)

Cat No Description

1756-ESMCAP Capacitor-based energy-storage module Comes with the controller

1756-EMNSE ESM without WallClockTime backup power Additionally you can use this ESM with a 1756-L73 (8 MB) or smaller memory-sized controller only

Use this ESM if your application requires that the installed ESM deplete its residual energy to 40 microJoule or less before transporting it into or out of your application

1756-ESMNRM Energy-storage module that secures the controller by preventing the USB connection and SD card useThis ESM provides your application an enhanced degree of security

Publication 1756-SG001P-EN-P - May 2011 31

1756 ControlLogix Batteries

Each 1756-L6x controller ships with a battery With a memory card installed the controller can be used without a battery If you do not use a battery current tag data will be at the state it was when the memory card was saved

ControlLogix Chassis The ControlLogix system is a modular system that requires a 1756 IO chassis Place any module into any slot The backplane provides a high-speed communication path between modules

All of the chassis are designed for horizontal-only back-panel mounting The chassis are available in these configurations

Standard chassis ControlLogix-XT chassis

For detailed specifications see 1756 ControlLogix Chassis Specifications Specifications publication 1756-TD006

Features - Chassis

Slot guides and snap-in retention for easy and secure module fit for any type of 1756 module

Direct mounting accommodates any 1756 power supply

Attribute 1756-BA1 1756-BA2 1756-BATM(1) 1756-BATA

Description Lithium battery (059 g) Lithium battery (059 g) Externally mounted battery assembly

Replacement lithium battery for 1756-BATM (5 g max lithium per each D cell contains 2 D cells)

ControlLogix controllers 1756-L61 1756-L62 1756-L63 series A

1756-L61 1756-L62 1756-L63 series B1756-L64 1756-L65

1756-L61 1756-L62 1756-L63 series A

1756-BATM battery module

GuardLogix controllers mdash 1756-L61S 1756-L62S 1756-L63S

mdash mdash

ControlLogix-XT controllers

mdash 1756-L63XT mdash mdash

(1) The 1756-BATM externally mounted battery assembly is highly recommended for use with all series A 1756-L6x controllers and provides longer battery life than the 1756-BA1 battery The 1756-BATM includes one 1756-BATA lithium battery assembly and a 1 m (328 ft) cable to connect housing to controller

32 Publication 1756-SG001P-EN-P - May 2011

Standard Chassis

The chassis backplane provides a high-speed communication path between modules and distributes power to each of the modules within the chassis

ControlLogix-XT Chassis

The ControlLogix-XT chassis support extreme temperature environments

Accessories - Chassis

Use a slot filler module to fill empty slots

Cat No Description Slots

1756-A4 ControlLogix standard chassis 4

1756-A7 7

1756-A10 10

1756-A13 13

1756-A17 17

Cat No Description Slots Temperature Range

1756-A4LXT ControlLogix-XT chassis 4 -2560 degC (-13140 degF)

1756-A5XT 5 -2570 degC (-13158 degF)

1756-A7LXT 7 -2560 degC (-13140 degF)

Cat No Description

1756-N2 Slot filler module for empty slots in standard ControlLogix chassis

1756-N2XT Slot filler module for empty slots in ControlLogix-XT chassis

Publication 1756-SG001P-EN-P - May 2011 33

ControlLogix Power Supplies

ControlLogix power supplies are used with the 1756 chassis to provide 12V 33V 5V and 24V DC power directly to the chassis backplane Select from these configurations

Standard power Redundant power ControlLogix-XT power

For detailed specifications see 1756 ControlLogix Power Supplies Specifications publication 1756-TD005

Standard Power Supplies

You mount a standard power supply directly on the left end of the chassis where it plugs directly into the backplane

ControlLogix-XT Power Supplies

The ControlLogix-XT power supplies support extreme temperature environments

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA72 ControlLogix standard AC 120V220V AC 85hellip265V AC Standard series A and series B

1756-PA75 120V220V AC 85hellip265V AC Standard series B

1756-PB72 ControlLogix standard DC 24V DC 18hellip32V DC Standard series A and series B

1756-PB75 24V DC 1832V DC Standard series B

1756-PC75 48V DC 30hellip60V DC Standard series B

1756-PH75 125V DC 90hellip143V DC Standard series B

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PAXT ControlLogix-XT AC power supply 85265V AC 120240V AC XT

1756-PBXT ControlLogix-XT DC power supply 24V DC 18hellip32V DC XT

34 Publication 1756-SG001P-EN-P - May 2011

Redundant Power Supplies

To build a redundant power supply system you need the following

Two redundant power supplies (both 1756-PA75R or 1756-PB75R) One 1756-PSCA2 chassis adapter module Two 1756-CPR2 cables to connect the power supplies to the

1756-PSCA2 chassis adapter module (091 m (3 ft) length) User-supplied annunciator wiring to connect the power supplies to the

input modules as needed

The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Accessories - Redundant Power Supplies

Visualization Products Visualization products together with Logix for control and NetLinx architecture for communication make up the Rockwell Automation Integrated Architecture strategy The visualization strategy combines Rockwell Automation expertise in Allen-Bradley electronic operator interface and industrialized personal computer hardware with Rockwell Software supervisory control software Current visualization products include the following

FactoryTalk View software PanelView Plus operator interface PanelView Plus CE operator interface Industrial computers and monitors

For more information see the Operator Interface catalog pages at httpwwwabcomenepubcatalogs1276221813761239781

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA75R ControlLogix redundant 120V220V AC 85hellip265V AC Standard series B

1756-PB75R 24V DC 192hellip32V DC Standard series B

Cat No Description Specifications

1756-PSCA2 Chassis adapter module Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Mounts directly to left side of 1756 chassis

1756-CPR2 Chassis adapter cable Connects redundant power supply to 1756-PCSA2 chassis adapter Length091 m (3 ft)

Publication 1756-SG001P-EN-P - May 2011 35

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN ltFEFF004200720075006700200069006e0064007300740069006c006c0069006e006700650072006e0065002000740069006c0020006100740020006f007000720065007400740065002000410064006f006200650020005000440046002d0064006f006b0075006d0065006e007400650072002000740069006c0020006b00760061006c00690074006500740073007500640073006b007200690076006e0069006e006700200065006c006c006500720020006b006f007200720065006b007400750072006c00e60073006e0069006e0067002e0020004400650020006f007000720065007400740065006400650020005000440046002d0064006f006b0075006d0065006e0074006500720020006b0061006e002000e50062006e00650073002000690020004100630072006f00620061007400200065006c006c006500720020004100630072006f006200610074002000520065006100640065007200200035002e00300020006f00670020006e0079006500720065002egt DEU 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 ESP ltFEFF005500740069006c0069006300650020006500730074006100200063006f006e0066006900670075007200610063006900f3006e0020007000610072006100200063007200650061007200200064006f00630075006d0065006e0074006f0073002000640065002000410064006f0062006500200050004400460020007000610072006100200063006f006e00730065006700750069007200200069006d0070007200650073006900f3006e002000640065002000630061006c006900640061006400200065006e00200069006d0070007200650073006f0072006100730020006400650020006500730063007200690074006f00720069006f00200079002000680065007200720061006d00690065006e00740061007300200064006500200063006f00720072006500630063006900f3006e002e002000530065002000700075006500640065006e00200061006200720069007200200064006f00630075006d0065006e0074006f00730020005000440046002000630072006500610064006f007300200063006f006e0020004100630072006f006200610074002c002000410064006f00620065002000520065006100640065007200200035002e003000200079002000760065007200730069006f006e0065007300200070006f00730074006500720069006f007200650073002egt FRA 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 ITA ltFEFF005500740069006c0069007a007a006100720065002000710075006500730074006500200069006d0070006f007300740061007a0069006f006e00690020007000650072002000630072006500610072006500200064006f00630075006d0065006e00740069002000410064006f006200650020005000440046002000700065007200200075006e00610020007300740061006d007000610020006400690020007100750061006c0069007400e00020007300750020007300740061006d00700061006e0074006900200065002000700072006f006f0066006500720020006400650073006b0074006f0070002e0020004900200064006f00630075006d0065006e007400690020005000440046002000630072006500610074006900200070006f00730073006f006e006f0020006500730073006500720065002000610070006500720074006900200063006f006e0020004100630072006f00620061007400200065002000410064006f00620065002000520065006100640065007200200035002e003000200065002000760065007200730069006f006e006900200073007500630063006500730073006900760065002egt JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

Contact Output Modules

Analog Input Modules

1756-OC8 8 outputs(4 pointsgroup)

48V DC source 3060V DC 1756-TBNH1756-TBSH

1756-OG16 16 (8 pointsgroup) 5V DC TTL source (Low=True)

4555V DC 1756-TBNH1756-TBSH

1756-OH8I 8 outputsindividually isolated

120V DC 90146V DC 1756-TBCH1756-TBS6H

1756-OV16E 16 electronically fused outputs(8 pointsgroup)

1224V DC sink 1030V DC 1756-TBNH1756-TBSH

1756-OV32E 32 electronically fused outputs (16 pointsgroup)

1224V DC sink 1030V DC 1756-TBCH1756-TBS6H

Cat No InputsOutputs Voltage Category Operating Voltage Range Removable Terminal Block

Cat No InputsOutputs Operating Voltage Range Removable Terminal Block

1756-OW16I 16 normally open individually isolated outputs 5150V DC10265V AC

1756-TBCH1756-TBS6H

1756-OX8I 8 normally open8 normally closed individually isolated outputs(2 pointsgroup)

5150V DC10265V AC

1756-TBCH1756-TBS6H

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-IF6CIS 6 individually isolated inputs current sourcing

0hellip21 mA 16 bits034 Abit

1756-TBNH1756-TBSH

1756-IF6I 6 individually isolated inputs plusmn105V0hellip105V0hellip525V0hellip21 mA

16 bits105V 343 Vbit0hellip105V 171 Vbit0hellip525V 86 Vbit0hellip21 mA 034 Abit

1756-TBNH1756-TBSH

1756-IF8 8 single-ended inputs4 differential inputs2 high-speed differential inputs

plusmn1025V01025V05125V0hellip205 mA

plusmn1025V 320 Vcnt (15 bits plus sign bipolar)0hellip1025V 160 Vcnt (16 bits)0hellip5125V 80 V cnt (16 bits)0hellip205mA 032 Acnt (16 bits)

1756-TBCH1756-TBS6H

10 Publication 1756-SG001P-EN-P - May 2011

Analog RTD and Thermocouple Modules

Analog Output Modules

1756-IF8H 8 differential voltage or current inputs HART interface

plusmn10V05V1hellip5V010V0hellip20 mA4hellip20 mA

16hellip21 bits 1756-TBCH1756-TBS6H

1756-IF16 16 single-ended inputs8 differential or 4 differential (high speed) inputs

plusmn105V0hellip105V0hellip525V0hellip21 mA

16 bits105V 343 Vbit0hellip105V 171 Vbit0hellip525V 86 Vbit0hellip21 mA 034 Abit

1756-TBCH1756-TBS6H

1756-IF16H 16 differential current inputs HART interface

0hellip20 mA4hellip20 mA

16hellip21 bits 1756-TBCH1756-TBS6H

Cat No InputsOutputs Range Resolution Removable Terminal Block

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-IR6I 6 individually isolated RTD inputs 1hellip487 2hellip1000 4hellip20008hellip4020

16 bits1hellip487 77 mbit2hellip1000 15 mbit4hellip2000 30 mbit8hellip4020 60 mbit

1756-TBNH1756-TBSH

1756-IT6I 6 individually isolated thermocouple inputs1 CJC

-12hellip78 mV-12hellip30 mV

16 bits-1278 mV 14 Vbit-1230 mV 07 Vbit

1756-TBNH1756-TBSH

1756-IT6I2 6 individually isolated thermocouple inputs2 CJC

-12hellip78 mV (14 V per bit)-12hellip30 mV (07 V per bit ndash high resolution range)

16 bits-1278 mV 14 Vbit-1230 mV 07 Vbit

1756-TBNH1756-TBSH

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-OF4 4 voltage or current outputs plusmn104V0hellip21 mA

Voltage15 bits across 105V 320 VbitCurrent15 bits across 21mA 650 nAbit

1756-TBNH1756-TBSH

1756-OF6CI 6 individually isolated outputs current

0hellip21 mA 13 bits across 21 mA (27 A) 1756-TBNH1756-TBSH

1756-OF6VI 6 individually isolated outputs voltage

plusmn105V 14 bits across 21V (13 mV)(13 bits across 105V +sign bit)

1756-TBNH1756-TBSH

1756-OF8 8 voltage or current outputs plusmn104V0hellip21 mA

15 bits across 21 mA - 650 nAbit15 bits across 104V - 320 Vbit

1756-TBNH1756-TBSH

1756-OF8H 8 voltage or current outputs HART interface

plusmn104V0hellip20 mA4hellip20 mA

15hellip16 bits 1756-TBNH1756-TBSH

Publication 1756-SG001P-EN-P - May 2011 11

Analog Combination Input and Output Module

Specialty IO Modules

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-IF4FXOF2F 4 high-speed sub-millisecond differential inputs2 high-speed voltage or current outputs

Inputplusmn105V0hellip105V0hellip525V0hellip21 mAOutputplusmn104V0hellip21 mA

InputApprox 14 bits across plusmn10V DC (21V total)plusmn10V 13 mVbit 14-bit effective0hellip105V 13 mVbit 13-bit effective0hellip525V 13 mVbit 12-bit effectiveApprox 12 bits across 21 mA0hellip21 mA 525 AbitOutput13 bits across 21 mA = 28 Abit14 bits across 218V = 13 mVbit

1756-TBCH1756-TBS6H

Cat No InputsOutputs Description Removable Terminal Block

1756-CFM 4 inputs (2 per channel) 2 outputs current sourcing

Configurable flowmeter module2 Flowmeter (F) inputs used for all modes2 Gate inputs used in Totalizer mode for proverstore count

1756-TBNH1756-TBSH

1756-HSC 2 counters each with 3 inputs (A B Z for gatereset)4 outputs (2 pointsgroup)

High-speed counter module5V operation 45hellip55V DC1224V operation 10hellip312V DC

1756-TBCH1756-TBS6H

1756-PLS Left section 2 groups of 4 outputs and 4 inputs eachCenter section resolver interface and IO controlRight section 2 groups of 4 outputs and 4 inputs each

Programmable limit switch module Requires 3 RTBs 1756-TBNH or 1756-TBSH

12 Publication 1756-SG001P-EN-P - May 2011

HART Smart Instrumentation

HART (Highway Addressable Remote Transmitter) is an open protocol designed to connect analog devices For HART connectivity select from products available from Rockwell Automation and our Encompass partners

Typical HART Configuration

HART Interfaces

Accessories - IO Modules

1756 Removable Terminal Blocks

Removable terminal blocks (RTBs) provide a flexible interconnection between your plant wiring and 1756 IO modules The RTB plugs into the front of the IO module The type of module determines which RTB you need You can choose screw-clamp or spring-clamp RTBs

RTBs are not shipped with IO modules You must order them separately The standard housing on the front of the wiring arm is not deep enough for 25 mm2

HART Devices

ControlLogix Controller with 1756-IF8H or 1756-OF8H module

If your application has Select Description

Analog and HART connectivity in one moduleNo external hardware required to access HART signalHART commands can be transmitted as unscheduled messagesSupports asset management software to HART device

1756-IF8H1756-IF16H1756-OF8H

Rockwell Automation analog IO modules

Data acquisition or control application with slow update requirements (such as a tank farm)No external hardware required to access HART signalDoes not connect directly to asset management software

MVI56-HART Prosoft interface

Analog and HART in one moduleInstrumentation in hazardous locations (FLEX Ex modules)HART commands can be transmitted as unscheduled messagesDirectly connects asset management software to HART devices

1794 FLEX IO1797 FLEX Ex IO

There are specific FLEX IO and FLEX Ex modules designed for HART systems These catalog numbers end in an H such as 1797-IE8H

Publication 1756-SG001P-EN-P - May 2011 13

(14 AWG) wiring If you plan to use 25 mm2 (14 AWG) wiring also order the extended housing

Wiring Systems

As an alternative to buying RTBs and connecting the wires yourself you can buy a wiring system of the following

Interface modules (IFMs) that provide the output terminal blocks for digital IO modules Use the pre-wired cables that match the IO module to the IFM

Analog interface modules (AIFMs) that provide the output terminal blocks for analog IO modules Use the pre-wired cables that match the IO module to the AIFM

IO module-ready cables One end of the cable assembly is an RTB that plugs into the front of the IO module The other end has individually color-coded conductors that connect to a standard terminal block

Attribute 1756-TBNH 1756-TBSH 1756-TBCH 1756-TBS6H 1756-TBE

Description 20-position NEMA screw-clamp removable block

20-pin spring-clamp removable terminal block with standard housing

36-pin cage-clamp removable terminal block with standard housing

36-pin spring-clamp removable terminal block with standard housing

Extended depth terminal block housing

Screw torque 08hellip1 Nbullm7hellip9 lbbullin

04 Nbullm44 lbbullin

mdash

Screwdriver width 8 mm (516 in) max

IO Module

RTBPre-wired Cable

Factory-wired

Interface Module (IFM)

Field Wiring

14 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Integrated Motion

The Logix architecture supports motion control components that work in a wide variety of machine architectures

Integrated motion on EtherNetIP supports a connection to Ethernet drives

The Kinetix integrated-motion solution uses a SERCOS interface module to perform multi-axis synchronized motion

Logix integrated motion supports the analog family of servo modules for controlling drivesactuators

Networked motion provides the ability to connect via the DeviceNet network to a single axis drive to perform point-to-point indexing

For detailed specifications on motion interface modules see 1756 ControlLogix Integrated Motion Specifications publication 1756-TD004

For more information see these publications

Motion Analyzer CD to size your motion application and to make final component selection Download the software from httpwwwabcommotionsoftwareanalyzerhtml

Kinetix Motion Control Selection Guide publication GMC-SG001 to verify drive motor and accessory specifications

Integrated Motion on an EtherNetIP Network

Product Consideration

Drive that supports EtherNetIP connections Unlimited velocity torque and Vhz configured drives Kinetix 6500 drives PowerFlex 755 drives

ControlLogix controller As many as 100 drives per controller

ControlLogix EtherNetIP communication module 1hellip8 position configured drives with 1756-EN2TR module 1hellip255 position configured drives with 1756-EN3TR module

Publication 1756-SG001P-EN-P - May 2011 15

SERCOS Interface Modules

The SERCOS interface modules can connect to these servo drives

2093 Kinetix 2000 multi-axis servo drive 2094 Kinetix 6000 multi-axis servo drive 2099 Kinetix 7000 high-power servo drive 2098 Ultra3000 SERCOS servo drive

ControlLogix Controller

PanelView Plus Terminal

Workstations

POINT IO ModulesDrive with EtherNetIP Connection

Cat No Description Number of Axis

1756-M16SE Rockwell Automation SERCOS interface modules 16

1756-M08SE 8

1756-M03SE 3

1756-M08SEG SERCOS interface drives that are Extended Pack Profile compliant 8

16 Publication 1756-SG001P-EN-P - May 2011

Analog Motion Interface Modules

RSLogix 5000 Software1756-MxxSE Module

ControlLogix Controller

Three-phase Input Power

Line Interface Module

Integrated Axis Module

Motor Motor Feedback

Axis Modules

Slot Filler Module

Shunt Module

SERCOS Fiber-optic RingKinetix 6000 Multi-axis Servo Drive

Cat No Description Number of Axis

1756-M02AE Analog servo interface drives with quadrature feedback 2

1756-HYD02 Analog hydraulic servo interface drives LDT feedback 2

1756-M02AS Analog servo interface drives with SSI feedback 2

Publication 1756-SG001P-EN-P - May 2011 17

ControlLogix Communication Modules

Separate communication modules are available for different networks Install multiple communication modules into the ControlLogix backplane to bridge or route control and information data between different networks You can route a message through a maximum of four chassis (eight communication hops) You do not need a ControlLogix controller in the chassis

For detailed specifications see 1756 ControlLogix Network Specifications publication 1756-TD003

Application Network Page

Plant management (material handling) Configuration data collection and control on a single high-speed network Time-critical applications with no established schedule Inclusion of commercial technologies (such as video over IP) InternetIntranet connection Integrated CIP motion and safety

EtherNetIP network 19

High-speed transfer of time-critical data between controllers and IO devices Deterministic and repeatable data delivery Media redundancy Intrinsic safety Redundant controller systems

ControlNet network 20

Connections of low-level devices directly to plant floor controllers without interfacing them through IO modules

Data sent as needed More diagnostics for improved data collection and fault detection Less wiring and reduced start-up time than a traditional hard-wired system

DeviceNet network 21

Plant-wide and cell-level data sharing with program maintenance Data sent regularly Transfer of information between controllers

Data Highway Plus network 23

Connections between controllers and IO adapters Data sent regularly Distributed control so that each controller has its own IO and communicates with a

supervisory controller

Remote IO network 23

Fieldbus transmitters and actuators Closed-loop control Process automation

Foundation Fieldbus network 25

18 Publication 1756-SG001P-EN-P - May 2011

EtherNetIP Communication Modules

The Ethernet Industrial (EtherNetIP) network protocol is an open industrial-networking standard that supports both real-time IO messaging and message exchange The EtherNetIP network uses off-the-shelf Ethernet communication chips and physical media

Accessories - EtherNetIP Network

Cat No Description Media Communication Rate

CIP Motion Axes max

TCPIP Connections

Logix Connections

1756-EN2F EtherNetIP bridge fiber Fiber 100 Mbps 8 128 256

1756-EN2T EtherNetIP bridge copper Copper 10100 Mbps 8 128 256

1756-EN2TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 8 128 256

1756-EN3TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 255 128 256

1756-ENBT EtherNetIP bridge copper Copper 10100 Mbps mdash 64 128

1756-EWEB Ethernet web server module Copper 10100 Mbps mdash 64 128

1756-EN2TXT ControlLogix-XT extended temperature EtherNetIP bridge copper for extreme environments

Copper 10100 Mbps 8 128 256

Cat No Description Specifications

1585J-M8PBJM-x Ethernet RJ45 patchcordx = 2 (2 m) 5 (5 m) or 10 (10 m)

8-conductor Teal Riser PVC Cable (Flex Rated cable also available)

1585J-M8CC-H RJ45 insulation displacement connector (IDC) 01280325 mm2 (26hellip22 AWG) Cat 6 IDC no tool required

1585J-M8CC-C RJ45 crimp connector with boot qty = 50 pieces 01280205 mm2 (26hellip24 AWG Cat 5e requires crimp tool for assembly

1585A-Jcrimp Crimp tool mdash

9300-RADES Remote access dial-in kit 56 Kbps modem connection to devices on an Ethernet network includes pre-configured modem communication module DIN rail mounting hardware associated cables

Publication 1756-SG001P-EN-P - May 2011 19

Example Configuration - EtherNetIP Network

ControlNet Communication ModulesThe ControlNet network combines the functionality of an IO network and a peer-to-peer network providing high-speed performance The ControlNet network provides deterministic repeatable transfers of critical control data

FirewallRouter

Stratix Switch

Stratix Switch

Stratix Switch

Powermonitor 3000PowerFlex 70

Ethernet PLC-5

MicroLogix

Ethernet SLC 500

1756 IO

1794 IO

1761-NET-ENI

ControlNet

DeviceNet

1734 IO

RSLinxPanelView Plus

1769-L35E CompactLogix

Cat No Description Communication Rate

Logix Connections Number of Nodes

1756-CN2B ControlNet bridge standard media 5 Mbps 128(1) 99

1756-CN2RB ControlNet bridge redundant media 5 Mbps 128(1) 99

1756-CNB ControlNet bridge standard media 5 Mbps 64(2) 99

1756-CNBR ControlNet bridge redundant media 5 Mbps 64(2) 99

1756-CN2RXT ControlLogix-XT extended temperature ControlNet bridge redundant media

5 Mbps 128(1) 99

(1) 128 connections are available for standard use An additional three connections are reserved for redundant control

(2) Recommend using only 4048 Logix connections for IO

20 Publication 1756-SG001P-EN-P - May 2011

Example Configuration - ControlNet Network

Example Configuration - Redundant ControlNet Media

For information on ControlNet media see ControlNet Media System Components List AG-PA002

DeviceNet Communication Module

The DeviceNet network provides connections between simple industrial devices (such as sensors and actuators) and higher-level devices (such as controllers and computers)

1784-U2CNPanelView Plus

1788-CN2DN

DeviceNetPowerFlex 700SPLC-540CControlLogix

Redundant Media

ControlLogix1756-CNBR

ControlNet Node

ControlNet Node

Cat No Description Communication Rate Number of Nodes

1756-DNB DeviceNet bridge 125 Kbps (500 m max)250 Kbps (250 m max)500 Kbps (100 m max)

64

Publication 1756-SG001P-EN-P - May 2011 21

Example Configuration - DeviceNet Network

Accessories - DeviceNet Network

PLC-51771-SDN ControlLogix

1756-DNB

Ultra3000

PanelView Plus1784-U2DN

Ultra5000

IO

Motor starter

PowerFlex AC

Sensor Pushbuttons

LightsBar Code Scanner

Cat No Description

KwikLink Lite flat media KwikLink Lite flat media is a newer ODVA-approved solution for wiring DeviceNet networks Drop-lines for connecting nodes are added by using the KwikLink Lite two-piece connectors This cable system supports the intermixing of DeviceNet cable types (thin-round with flat) All of the KwikLink Lite connectors provide insulation displacement technology with reduced assembly time

KwikLink flat media The KwikLink flat media system provides a modular cabling method with its flat 4-wire cable and insulation displacement connectors (IDCs) The KwikLink system allows nodes to be added to the network without severing the trunkline Cutting or stripping of the trunkline is eliminated as is the need for predetermined cable lengths

Round media Round trunk cable is available in bulk spools or as pre-molded cordsets or patchcords in varying lengths A wide variety of rugged durable DeviceNet components is available for use in round trunk systems Stainless steel versions of round cable system components are also available Thick-trunk round media systems use thick cable for maximum DeviceNet trunk line length Round media thin-trunk systems use thin cable to reduce maximum trunk line distances with a more

compact and cost-effective installation for some applications Thin-cable outer jacket material is TPE for additional chemical resistance

22 Publication 1756-SG001P-EN-P - May 2011

Data Highway Plus and Remote IO Communication Modules

The Data Highway Plus network supports messaging between devices The remote IO link connects to remote IO chassis and other intelligent devices

The 1756-DHRIO module supports messaging between devices on DH+ networks The remote IO functionality enables the module to act as a scanner for transferring digital and block-transfer data to and from remote IO devices

The 1756-RIO module can act as a scanner or adapter on a remote IO network In addition to digital and block-transfer data the 1756-RIO module transfers analog and specialty data without message instructions

Cat No Description Communication Rate DH+ Connections RIO Connections Maximum Recommended Logix Connections

1756-DHRIO Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

1756-RIO Remote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

mdash Remote IO scanner or adapter32 physical racks (076) any combination of rack size and block transfers

10 scheduled IO

1756-DHRIOXT ControlLogix-XT extended temperature Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

Publication 1756-SG001P-EN-P - May 2011 23

Example Configuration - DH+ Network

Example Configuration - Remote IO Network

Accessories - DH+ and Remote IO Networks

PanelView Plus

PLC-5 1784-U2DHPRSLogix 5000

ControlLogix1756-DHRIO

SLC 504

PanelView PlusPLC-5

1791 IO1794 IO

1756-RIO as a Remote IO Adapter

1756-DHRIO as a Remote IO Scanner

Cat No Description Specifications

1770-CD Cable to connect communication module to DH+ network Belden 9463 twinaxial

9300-RADKIT Remote access dial-in kit 56 Kbps modem connection to devices on a DH+ network includes pre-configured modem communication module DIN rail mounting hardware associated cables

24 Publication 1756-SG001P-EN-P - May 2011

FOUNDATION Fieldbus Linking Devices

The FOUNDATION Fieldbus protocol is a network designed for distributed control of process applications

Example Configuration - Bridge to EtherNetIP Network

Cat No Description Communication Rate Number of H1 Ports

Devices per H1 Link

Devices per Linking Device

1757FFLD2 FOUNDATION Fieldbus bridge to an Ethernet network

FOUNDATION Fieldbus 3125 KbpsEtherNetIP 10100 Mbps

2 16(8hellip10 recommended)

32

1757-FFLD4 4 64

1757-FFLDC2 FOUNDATION Fieldbus bridge to a ControlNet network

FOUNDATION Fieldbus 3125 KbpsControlNet 5 Mbps

2 16(8hellip10 recommended)

32

1757-FFLDC4 4 64

FactoryTalk View SERSFieldbusRSLogix 5000

1757-FFLD4

H1(1)

H1(2)H1(3)H1(4)

HSEIP

Publication 1756-SG001P-EN-P - May 2011 25

Example Configuration - Bridge to ControlNet Network

Other Connectivity Options

ControlLogix RedundancyFactoryTalk View SERSFieldbusRSLogix 5000

ControlNet Redundant Media

1757-FFLDC2

FF H1

EtherNetIP

Option Consideration

USB connection The 1756-L7x controller has a USB port in place of the serial port If your application requires RS-232 functionality see the many Encompass partners at httpwwwrockwellautomationcomencompass

Serial connection The serial port on the 1756-L6x controller is compatible with RS-232 serial communication The serial port supports the DF1 protocol to communicate with other devices on the serial linkTo use Logix5000 controllers on Modbus you connect through the serial port and execute a specific ladder logic routine The controller project is available with RSLogix 5000 Enterprise programming software For more information see Using Logix5000 Controllers as Masters or Slaves on Modbus Application Solution publication CIG-AP129

DH-485 network The controller serial port is compatible with DH-485 communication The DH-485 connection does support remote programming and monitoring via RSLogix 5000 softwareOr add a DH-485 communication bridge module (cat no 1756-DH485)

SynchLink network The SynchLink communication module (1756-SYNCH) provides time synchronization and data broadcasting capabilities for distributed motion and coordinated drive control The module connects a ControlLogix chassis to a SynchLink fiber-optic communication link

26 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Controllers The ControlLogix controller provides a scalable controller solution that is capable of addressing a large amount of IO points

The controller can be placed into any slot of a ControlLogix chassis and multiple controllers can be installed in the same chassis Multiple controllers in the same chassis communicate with each other over the backplane (just as controllers can communicate over networks) but operate independently

ControlLogix controllers can monitor and control IO across the ControlLogix backplane as well as over IO links ControlLogix controllers can communicate over EtherNetIP ControlNet DeviceNet DH+ Remote IO and RS-232-C (DF1DH-485 protocol) networks and many third party process and device networks To provide communication for a ControlLogix controller install the appropriate communication interface module into the chassis

For detailed specifications see 1756 ControlLogix Controllers Specifications publication 1756-TD001

Cat No Description User Memory

1756-L72 ControlLogix controller 1 built-in USB port 4 MB

1756-L73 8 MB

1756-L74 16 MB

1756-L75 32 MB

1756-L61 ControlLogix controller 1 built-in RS-232 port 2 MB

1756-L62 4 MB

1756-L63 8 MB

1756-L64 16 MB

1756-L65 32 MB

1756-L61S GuardLogix safety controller 2 MB standard1 MB safety

1756-L62S 4 MB standard1 MB safety

1756-L63S 8 MB standard375 MB safety

1756-LSP GuardLogix safety partner (one is required for each GuardLogix controller) mdash

1756-L63XT ControlLogix-XT controller extreme environment 8 MB

IMPORTANT Scan time for a project loaded in a 1756-L64 or 1756-L65 controller may be slower than for the same project loaded in one of the other 1756-L6x controllers See the Logix5000 Controllers Instruction Execution Time and Memory Use Reference Manual publication 1756-RM087 for instruction execution times

Publication 1756-SG001P-EN-P - May 2011 27

Standard ControlLogix Controllers

The ControlLogix controller is part of the Logix5000 family of controllers A ControlLogix system includes the following

The ControlLogix controller available in different combinations of user memory

RSLogix 5000 programming software 1756 ControlLogix IO modules that reside in a 1756 chassis Separate communication modules for network communication

Features - Standard ControlLogix Controllers

Feature 1756-L61 1756-L62 1756-L63 1756-L64 1756-L65

1756-L72 1756-L73 1756-L74 1756-L75

Controller tasks 32 tasks 100 programstask Event tasks all event triggers

Built-in communication ports 1 port RS-232 serial 1 port USB

Communication options EtherNetIP ControlNet DeviceNet Data Highway Plus Remote IO SynchLink Third-party process and device networks

Built-in port Serial USB

Controller connections supported max 250 500

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Full support

Integrated motion EtherNetIP connection SERCOS interface Analog options (encoder input LDT input SSI input)

Programming languages Relay ladder Structured text Function block SFC

28 Publication 1756-SG001P-EN-P - May 2011

GuardLogix Controllers

A GuardLogix controller is a ControlLogix controller that also provides safety control The GuardLogix system is a dual controller solutionmdashyou must use a 1756-L6xS primary controller and a 1756-LSP safety partner to achieve SIL 3CAT 4

During development safety and standard have the same rules multiple programmers online editing and forcing are all allowed Once the project is tested and ready for final validation you set the Safety Task to a SIL 3 integrity level which is then enforced by the GuardLogix controller When safety memory is locked and protected the safety logic cant be modified and all safety functions operate with SIL 3 integrity On the standard side of the GuardLogix controller all functions operate like a regular Logix controller

Use Guard IO modules for field device connectivity on Ethernet or DeviceNet networks and for safety interlocking between GuardLogix controllers use Ethernet or ControlNet networks Multiple GuardLogix controllers can share safety data for zone to zone interlocking or a single GuardLogix controller can use remote distributed safety IO between different cellsareas

In addition to the standard features of a ControlLogix controller the GuardLogix controller has these safety-related features

Application Description

SIL 1 2 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508 and applications up to and including PLeCat4 according to ISO 13849-1 For more information see GuardLogix Controllers Systems Safety Reference Manual publication 1756-RM093 GuardLogix Controllers User Manual publication 1756-UM020 GuardLogix Safety Application Instruction Set Reference Manual publication 1756-RM095

Features - GuardLogix Controllers

Feature 1756-L61S 1756-L62S 1756-L63S 1756-LSP

Safety communication options Standard and safety EtherNetIP ControlNet DeviceNet

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Not supported

Programming languages Relay ladder

Publication 1756-SG001P-EN-P - May 2011 29

ControlLogix-XT Controllers

The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh corrosive environments

When used with FLEX IO-XT products the ControlLogix-XT system can withstand temperatures range from -2070 C (-4158 F)

When used independently the ControlLogix-XT system can withstand temperature ranges from -2570 C (-13158 F)

Redundant ControlLogix Controllers

The ControlLogix controller supports controller redundancy In a redundant controller system you need these components

Two 1756 chassis each with the following the same ndash Number of slots

ndash Modules in the same slots

ndash Redundancy firmware revisions in each module

ndash Two additional ControlNet nodes outside the redundant chassis pair

You need one of these redundancy modules

One 1756-RM module per chassis that supports the followingndash Two 1756-L61 1756-L62 1761-L63 controllers or one 1756-L64

controller

ndash Maximum of seven communication modules which can be 1756-CN2 series B 1756-CN2R series B and 1756-EN2T modules

ndash One 1756-RMCx cable

One 1757-SRM module per chassis that supports the followingndash One 1756-L61 1756-L62 1756-L63 1756-L64 controller

ndash Maximum of seven communication modules which can be 1756-CNB series D or E 1756-CNBR series D or E 1756-ENBT and 1756-EWEB modules

ndash One 1757-SRCx cable

30 Publication 1756-SG001P-EN-P - May 2011

Accessories - Controllers

Memory Cards

Memory cards offer nonvolatile memory to permanently store a user program and tag data on a controller The 1756-L7x ControlLogix controller comes with 1784-SD1 Secure Digital (SD) card already installed The 1756-L6x controllers support optional CompactFlash cards that you purchase separately The memory card installs in a socket on the controller Through RSLogix 5000 software you can manually trigger the controller to save to or load from nonvolatile memory or configure the controller to load from nonvolatile memory on powerup

The GuardLogix controller does not support user program storage or retrieval by using a CompactFlash card

1756 Energy Storage Modules

Instead of a battery the 1756-L7x controller ships with a 1756-ESMCAP energy storage module (ESM) already installed

Attribute 1784-CF64 1784-CF128 1784-SD1 1784-SD2

Memory 64 MB 128 MB 1 GB 2 GB

Supported controllers 1756-L6x 1756-L7x

Weight approx 142 g (05 oz) 176 g (0062 oz)

Cat No Description

1756-ESMCAP Capacitor-based energy-storage module Comes with the controller

1756-EMNSE ESM without WallClockTime backup power Additionally you can use this ESM with a 1756-L73 (8 MB) or smaller memory-sized controller only

Use this ESM if your application requires that the installed ESM deplete its residual energy to 40 microJoule or less before transporting it into or out of your application

1756-ESMNRM Energy-storage module that secures the controller by preventing the USB connection and SD card useThis ESM provides your application an enhanced degree of security

Publication 1756-SG001P-EN-P - May 2011 31

1756 ControlLogix Batteries

Each 1756-L6x controller ships with a battery With a memory card installed the controller can be used without a battery If you do not use a battery current tag data will be at the state it was when the memory card was saved

ControlLogix Chassis The ControlLogix system is a modular system that requires a 1756 IO chassis Place any module into any slot The backplane provides a high-speed communication path between modules

All of the chassis are designed for horizontal-only back-panel mounting The chassis are available in these configurations

Standard chassis ControlLogix-XT chassis

For detailed specifications see 1756 ControlLogix Chassis Specifications Specifications publication 1756-TD006

Features - Chassis

Slot guides and snap-in retention for easy and secure module fit for any type of 1756 module

Direct mounting accommodates any 1756 power supply

Attribute 1756-BA1 1756-BA2 1756-BATM(1) 1756-BATA

Description Lithium battery (059 g) Lithium battery (059 g) Externally mounted battery assembly

Replacement lithium battery for 1756-BATM (5 g max lithium per each D cell contains 2 D cells)

ControlLogix controllers 1756-L61 1756-L62 1756-L63 series A

1756-L61 1756-L62 1756-L63 series B1756-L64 1756-L65

1756-L61 1756-L62 1756-L63 series A

1756-BATM battery module

GuardLogix controllers mdash 1756-L61S 1756-L62S 1756-L63S

mdash mdash

ControlLogix-XT controllers

mdash 1756-L63XT mdash mdash

(1) The 1756-BATM externally mounted battery assembly is highly recommended for use with all series A 1756-L6x controllers and provides longer battery life than the 1756-BA1 battery The 1756-BATM includes one 1756-BATA lithium battery assembly and a 1 m (328 ft) cable to connect housing to controller

32 Publication 1756-SG001P-EN-P - May 2011

Standard Chassis

The chassis backplane provides a high-speed communication path between modules and distributes power to each of the modules within the chassis

ControlLogix-XT Chassis

The ControlLogix-XT chassis support extreme temperature environments

Accessories - Chassis

Use a slot filler module to fill empty slots

Cat No Description Slots

1756-A4 ControlLogix standard chassis 4

1756-A7 7

1756-A10 10

1756-A13 13

1756-A17 17

Cat No Description Slots Temperature Range

1756-A4LXT ControlLogix-XT chassis 4 -2560 degC (-13140 degF)

1756-A5XT 5 -2570 degC (-13158 degF)

1756-A7LXT 7 -2560 degC (-13140 degF)

Cat No Description

1756-N2 Slot filler module for empty slots in standard ControlLogix chassis

1756-N2XT Slot filler module for empty slots in ControlLogix-XT chassis

Publication 1756-SG001P-EN-P - May 2011 33

ControlLogix Power Supplies

ControlLogix power supplies are used with the 1756 chassis to provide 12V 33V 5V and 24V DC power directly to the chassis backplane Select from these configurations

Standard power Redundant power ControlLogix-XT power

For detailed specifications see 1756 ControlLogix Power Supplies Specifications publication 1756-TD005

Standard Power Supplies

You mount a standard power supply directly on the left end of the chassis where it plugs directly into the backplane

ControlLogix-XT Power Supplies

The ControlLogix-XT power supplies support extreme temperature environments

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA72 ControlLogix standard AC 120V220V AC 85hellip265V AC Standard series A and series B

1756-PA75 120V220V AC 85hellip265V AC Standard series B

1756-PB72 ControlLogix standard DC 24V DC 18hellip32V DC Standard series A and series B

1756-PB75 24V DC 1832V DC Standard series B

1756-PC75 48V DC 30hellip60V DC Standard series B

1756-PH75 125V DC 90hellip143V DC Standard series B

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PAXT ControlLogix-XT AC power supply 85265V AC 120240V AC XT

1756-PBXT ControlLogix-XT DC power supply 24V DC 18hellip32V DC XT

34 Publication 1756-SG001P-EN-P - May 2011

Redundant Power Supplies

To build a redundant power supply system you need the following

Two redundant power supplies (both 1756-PA75R or 1756-PB75R) One 1756-PSCA2 chassis adapter module Two 1756-CPR2 cables to connect the power supplies to the

1756-PSCA2 chassis adapter module (091 m (3 ft) length) User-supplied annunciator wiring to connect the power supplies to the

input modules as needed

The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Accessories - Redundant Power Supplies

Visualization Products Visualization products together with Logix for control and NetLinx architecture for communication make up the Rockwell Automation Integrated Architecture strategy The visualization strategy combines Rockwell Automation expertise in Allen-Bradley electronic operator interface and industrialized personal computer hardware with Rockwell Software supervisory control software Current visualization products include the following

FactoryTalk View software PanelView Plus operator interface PanelView Plus CE operator interface Industrial computers and monitors

For more information see the Operator Interface catalog pages at httpwwwabcomenepubcatalogs1276221813761239781

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA75R ControlLogix redundant 120V220V AC 85hellip265V AC Standard series B

1756-PB75R 24V DC 192hellip32V DC Standard series B

Cat No Description Specifications

1756-PSCA2 Chassis adapter module Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Mounts directly to left side of 1756 chassis

1756-CPR2 Chassis adapter cable Connects redundant power supply to 1756-PCSA2 chassis adapter Length091 m (3 ft)

Publication 1756-SG001P-EN-P - May 2011 35

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN ltFEFF004200720075006700200069006e0064007300740069006c006c0069006e006700650072006e0065002000740069006c0020006100740020006f007000720065007400740065002000410064006f006200650020005000440046002d0064006f006b0075006d0065006e007400650072002000740069006c0020006b00760061006c00690074006500740073007500640073006b007200690076006e0069006e006700200065006c006c006500720020006b006f007200720065006b007400750072006c00e60073006e0069006e0067002e0020004400650020006f007000720065007400740065006400650020005000440046002d0064006f006b0075006d0065006e0074006500720020006b0061006e002000e50062006e00650073002000690020004100630072006f00620061007400200065006c006c006500720020004100630072006f006200610074002000520065006100640065007200200035002e00300020006f00670020006e0079006500720065002egt DEU ltFEFF00560065007200770065006e00640065006e0020005300690065002000640069006500730065002000450069006e007300740065006c006c0075006e00670065006e0020007a0075006d002000450072007300740065006c006c0065006e00200076006f006e002000410064006f006200650020005000440046002d0044006f006b0075006d0065006e00740065006e002c00200076006f006e002000640065006e0065006e002000530069006500200068006f00630068007700650072007400690067006500200044007200750063006b006500200061007500660020004400650073006b0074006f0070002d0044007200750063006b00650072006e00200075006e0064002000500072006f006f0066002d00470065007200e400740065006e002000650072007a0065007500670065006e0020006d00f60063006800740065006e002e002000450072007300740065006c006c007400650020005000440046002d0044006f006b0075006d0065006e007400650020006b00f6006e006e0065006e0020006d006900740020004100630072006f00620061007400200075006e0064002000410064006f00620065002000520065006100640065007200200035002e00300020006f0064006500720020006800f600680065007200200067006500f600660066006e00650074002000770065007200640065006e002egt ESP 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 FRA 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 ITA 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 JPN ltFEFF9ad854c18cea51fa529b7528002000410064006f0062006500200050004400460020658766f8306e4f5c6210306b4f7f75283057307e30593002537052376642306e753b8cea3092670059279650306b4fdd306430533068304c3067304d307e3059300230c730b930af30c830c330d730d730ea30f330bf3067306e53705237307e305f306f30d730eb30fc30d57528306b9069305730663044307e305930023053306e8a2d5b9a30674f5c62103055308c305f0020005000440046002030d530a130a430eb306f3001004100630072006f0062006100740020304a30883073002000410064006f00620065002000520065006100640065007200200035002e003000204ee5964d3067958b304f30533068304c3067304d307e30593002gt KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE ltFEFF0041006e007600e4006e00640020006400650020006800e4007200200069006e0073007400e4006c006c006e0069006e006700610072006e00610020006f006d002000640075002000760069006c006c00200073006b006100700061002000410064006f006200650020005000440046002d0064006f006b0075006d0065006e00740020006600f600720020006b00760061006c00690074006500740073007500740073006b0072006900660074006500720020007000e5002000760061006e006c00690067006100200073006b0072006900760061007200650020006f006300680020006600f600720020006b006f007200720065006b007400750072002e002000200053006b006100700061006400650020005000440046002d0064006f006b0075006d0065006e00740020006b0061006e002000f600700070006e00610073002000690020004100630072006f0062006100740020006f00630068002000410064006f00620065002000520065006100640065007200200035002e00300020006f00630068002000730065006e006100720065002egt ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

Analog RTD and Thermocouple Modules

Analog Output Modules

1756-IF8H 8 differential voltage or current inputs HART interface

plusmn10V05V1hellip5V010V0hellip20 mA4hellip20 mA

16hellip21 bits 1756-TBCH1756-TBS6H

1756-IF16 16 single-ended inputs8 differential or 4 differential (high speed) inputs

plusmn105V0hellip105V0hellip525V0hellip21 mA

16 bits105V 343 Vbit0hellip105V 171 Vbit0hellip525V 86 Vbit0hellip21 mA 034 Abit

1756-TBCH1756-TBS6H

1756-IF16H 16 differential current inputs HART interface

0hellip20 mA4hellip20 mA

16hellip21 bits 1756-TBCH1756-TBS6H

Cat No InputsOutputs Range Resolution Removable Terminal Block

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-IR6I 6 individually isolated RTD inputs 1hellip487 2hellip1000 4hellip20008hellip4020

16 bits1hellip487 77 mbit2hellip1000 15 mbit4hellip2000 30 mbit8hellip4020 60 mbit

1756-TBNH1756-TBSH

1756-IT6I 6 individually isolated thermocouple inputs1 CJC

-12hellip78 mV-12hellip30 mV

16 bits-1278 mV 14 Vbit-1230 mV 07 Vbit

1756-TBNH1756-TBSH

1756-IT6I2 6 individually isolated thermocouple inputs2 CJC

-12hellip78 mV (14 V per bit)-12hellip30 mV (07 V per bit ndash high resolution range)

16 bits-1278 mV 14 Vbit-1230 mV 07 Vbit

1756-TBNH1756-TBSH

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-OF4 4 voltage or current outputs plusmn104V0hellip21 mA

Voltage15 bits across 105V 320 VbitCurrent15 bits across 21mA 650 nAbit

1756-TBNH1756-TBSH

1756-OF6CI 6 individually isolated outputs current

0hellip21 mA 13 bits across 21 mA (27 A) 1756-TBNH1756-TBSH

1756-OF6VI 6 individually isolated outputs voltage

plusmn105V 14 bits across 21V (13 mV)(13 bits across 105V +sign bit)

1756-TBNH1756-TBSH

1756-OF8 8 voltage or current outputs plusmn104V0hellip21 mA

15 bits across 21 mA - 650 nAbit15 bits across 104V - 320 Vbit

1756-TBNH1756-TBSH

1756-OF8H 8 voltage or current outputs HART interface

plusmn104V0hellip20 mA4hellip20 mA

15hellip16 bits 1756-TBNH1756-TBSH

Publication 1756-SG001P-EN-P - May 2011 11

Analog Combination Input and Output Module

Specialty IO Modules

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-IF4FXOF2F 4 high-speed sub-millisecond differential inputs2 high-speed voltage or current outputs

Inputplusmn105V0hellip105V0hellip525V0hellip21 mAOutputplusmn104V0hellip21 mA

InputApprox 14 bits across plusmn10V DC (21V total)plusmn10V 13 mVbit 14-bit effective0hellip105V 13 mVbit 13-bit effective0hellip525V 13 mVbit 12-bit effectiveApprox 12 bits across 21 mA0hellip21 mA 525 AbitOutput13 bits across 21 mA = 28 Abit14 bits across 218V = 13 mVbit

1756-TBCH1756-TBS6H

Cat No InputsOutputs Description Removable Terminal Block

1756-CFM 4 inputs (2 per channel) 2 outputs current sourcing

Configurable flowmeter module2 Flowmeter (F) inputs used for all modes2 Gate inputs used in Totalizer mode for proverstore count

1756-TBNH1756-TBSH

1756-HSC 2 counters each with 3 inputs (A B Z for gatereset)4 outputs (2 pointsgroup)

High-speed counter module5V operation 45hellip55V DC1224V operation 10hellip312V DC

1756-TBCH1756-TBS6H

1756-PLS Left section 2 groups of 4 outputs and 4 inputs eachCenter section resolver interface and IO controlRight section 2 groups of 4 outputs and 4 inputs each

Programmable limit switch module Requires 3 RTBs 1756-TBNH or 1756-TBSH

12 Publication 1756-SG001P-EN-P - May 2011

HART Smart Instrumentation

HART (Highway Addressable Remote Transmitter) is an open protocol designed to connect analog devices For HART connectivity select from products available from Rockwell Automation and our Encompass partners

Typical HART Configuration

HART Interfaces

Accessories - IO Modules

1756 Removable Terminal Blocks

Removable terminal blocks (RTBs) provide a flexible interconnection between your plant wiring and 1756 IO modules The RTB plugs into the front of the IO module The type of module determines which RTB you need You can choose screw-clamp or spring-clamp RTBs

RTBs are not shipped with IO modules You must order them separately The standard housing on the front of the wiring arm is not deep enough for 25 mm2

HART Devices

ControlLogix Controller with 1756-IF8H or 1756-OF8H module

If your application has Select Description

Analog and HART connectivity in one moduleNo external hardware required to access HART signalHART commands can be transmitted as unscheduled messagesSupports asset management software to HART device

1756-IF8H1756-IF16H1756-OF8H

Rockwell Automation analog IO modules

Data acquisition or control application with slow update requirements (such as a tank farm)No external hardware required to access HART signalDoes not connect directly to asset management software

MVI56-HART Prosoft interface

Analog and HART in one moduleInstrumentation in hazardous locations (FLEX Ex modules)HART commands can be transmitted as unscheduled messagesDirectly connects asset management software to HART devices

1794 FLEX IO1797 FLEX Ex IO

There are specific FLEX IO and FLEX Ex modules designed for HART systems These catalog numbers end in an H such as 1797-IE8H

Publication 1756-SG001P-EN-P - May 2011 13

(14 AWG) wiring If you plan to use 25 mm2 (14 AWG) wiring also order the extended housing

Wiring Systems

As an alternative to buying RTBs and connecting the wires yourself you can buy a wiring system of the following

Interface modules (IFMs) that provide the output terminal blocks for digital IO modules Use the pre-wired cables that match the IO module to the IFM

Analog interface modules (AIFMs) that provide the output terminal blocks for analog IO modules Use the pre-wired cables that match the IO module to the AIFM

IO module-ready cables One end of the cable assembly is an RTB that plugs into the front of the IO module The other end has individually color-coded conductors that connect to a standard terminal block

Attribute 1756-TBNH 1756-TBSH 1756-TBCH 1756-TBS6H 1756-TBE

Description 20-position NEMA screw-clamp removable block

20-pin spring-clamp removable terminal block with standard housing

36-pin cage-clamp removable terminal block with standard housing

36-pin spring-clamp removable terminal block with standard housing

Extended depth terminal block housing

Screw torque 08hellip1 Nbullm7hellip9 lbbullin

04 Nbullm44 lbbullin

mdash

Screwdriver width 8 mm (516 in) max

IO Module

RTBPre-wired Cable

Factory-wired

Interface Module (IFM)

Field Wiring

14 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Integrated Motion

The Logix architecture supports motion control components that work in a wide variety of machine architectures

Integrated motion on EtherNetIP supports a connection to Ethernet drives

The Kinetix integrated-motion solution uses a SERCOS interface module to perform multi-axis synchronized motion

Logix integrated motion supports the analog family of servo modules for controlling drivesactuators

Networked motion provides the ability to connect via the DeviceNet network to a single axis drive to perform point-to-point indexing

For detailed specifications on motion interface modules see 1756 ControlLogix Integrated Motion Specifications publication 1756-TD004

For more information see these publications

Motion Analyzer CD to size your motion application and to make final component selection Download the software from httpwwwabcommotionsoftwareanalyzerhtml

Kinetix Motion Control Selection Guide publication GMC-SG001 to verify drive motor and accessory specifications

Integrated Motion on an EtherNetIP Network

Product Consideration

Drive that supports EtherNetIP connections Unlimited velocity torque and Vhz configured drives Kinetix 6500 drives PowerFlex 755 drives

ControlLogix controller As many as 100 drives per controller

ControlLogix EtherNetIP communication module 1hellip8 position configured drives with 1756-EN2TR module 1hellip255 position configured drives with 1756-EN3TR module

Publication 1756-SG001P-EN-P - May 2011 15

SERCOS Interface Modules

The SERCOS interface modules can connect to these servo drives

2093 Kinetix 2000 multi-axis servo drive 2094 Kinetix 6000 multi-axis servo drive 2099 Kinetix 7000 high-power servo drive 2098 Ultra3000 SERCOS servo drive

ControlLogix Controller

PanelView Plus Terminal

Workstations

POINT IO ModulesDrive with EtherNetIP Connection

Cat No Description Number of Axis

1756-M16SE Rockwell Automation SERCOS interface modules 16

1756-M08SE 8

1756-M03SE 3

1756-M08SEG SERCOS interface drives that are Extended Pack Profile compliant 8

16 Publication 1756-SG001P-EN-P - May 2011

Analog Motion Interface Modules

RSLogix 5000 Software1756-MxxSE Module

ControlLogix Controller

Three-phase Input Power

Line Interface Module

Integrated Axis Module

Motor Motor Feedback

Axis Modules

Slot Filler Module

Shunt Module

SERCOS Fiber-optic RingKinetix 6000 Multi-axis Servo Drive

Cat No Description Number of Axis

1756-M02AE Analog servo interface drives with quadrature feedback 2

1756-HYD02 Analog hydraulic servo interface drives LDT feedback 2

1756-M02AS Analog servo interface drives with SSI feedback 2

Publication 1756-SG001P-EN-P - May 2011 17

ControlLogix Communication Modules

Separate communication modules are available for different networks Install multiple communication modules into the ControlLogix backplane to bridge or route control and information data between different networks You can route a message through a maximum of four chassis (eight communication hops) You do not need a ControlLogix controller in the chassis

For detailed specifications see 1756 ControlLogix Network Specifications publication 1756-TD003

Application Network Page

Plant management (material handling) Configuration data collection and control on a single high-speed network Time-critical applications with no established schedule Inclusion of commercial technologies (such as video over IP) InternetIntranet connection Integrated CIP motion and safety

EtherNetIP network 19

High-speed transfer of time-critical data between controllers and IO devices Deterministic and repeatable data delivery Media redundancy Intrinsic safety Redundant controller systems

ControlNet network 20

Connections of low-level devices directly to plant floor controllers without interfacing them through IO modules

Data sent as needed More diagnostics for improved data collection and fault detection Less wiring and reduced start-up time than a traditional hard-wired system

DeviceNet network 21

Plant-wide and cell-level data sharing with program maintenance Data sent regularly Transfer of information between controllers

Data Highway Plus network 23

Connections between controllers and IO adapters Data sent regularly Distributed control so that each controller has its own IO and communicates with a

supervisory controller

Remote IO network 23

Fieldbus transmitters and actuators Closed-loop control Process automation

Foundation Fieldbus network 25

18 Publication 1756-SG001P-EN-P - May 2011

EtherNetIP Communication Modules

The Ethernet Industrial (EtherNetIP) network protocol is an open industrial-networking standard that supports both real-time IO messaging and message exchange The EtherNetIP network uses off-the-shelf Ethernet communication chips and physical media

Accessories - EtherNetIP Network

Cat No Description Media Communication Rate

CIP Motion Axes max

TCPIP Connections

Logix Connections

1756-EN2F EtherNetIP bridge fiber Fiber 100 Mbps 8 128 256

1756-EN2T EtherNetIP bridge copper Copper 10100 Mbps 8 128 256

1756-EN2TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 8 128 256

1756-EN3TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 255 128 256

1756-ENBT EtherNetIP bridge copper Copper 10100 Mbps mdash 64 128

1756-EWEB Ethernet web server module Copper 10100 Mbps mdash 64 128

1756-EN2TXT ControlLogix-XT extended temperature EtherNetIP bridge copper for extreme environments

Copper 10100 Mbps 8 128 256

Cat No Description Specifications

1585J-M8PBJM-x Ethernet RJ45 patchcordx = 2 (2 m) 5 (5 m) or 10 (10 m)

8-conductor Teal Riser PVC Cable (Flex Rated cable also available)

1585J-M8CC-H RJ45 insulation displacement connector (IDC) 01280325 mm2 (26hellip22 AWG) Cat 6 IDC no tool required

1585J-M8CC-C RJ45 crimp connector with boot qty = 50 pieces 01280205 mm2 (26hellip24 AWG Cat 5e requires crimp tool for assembly

1585A-Jcrimp Crimp tool mdash

9300-RADES Remote access dial-in kit 56 Kbps modem connection to devices on an Ethernet network includes pre-configured modem communication module DIN rail mounting hardware associated cables

Publication 1756-SG001P-EN-P - May 2011 19

Example Configuration - EtherNetIP Network

ControlNet Communication ModulesThe ControlNet network combines the functionality of an IO network and a peer-to-peer network providing high-speed performance The ControlNet network provides deterministic repeatable transfers of critical control data

FirewallRouter

Stratix Switch

Stratix Switch

Stratix Switch

Powermonitor 3000PowerFlex 70

Ethernet PLC-5

MicroLogix

Ethernet SLC 500

1756 IO

1794 IO

1761-NET-ENI

ControlNet

DeviceNet

1734 IO

RSLinxPanelView Plus

1769-L35E CompactLogix

Cat No Description Communication Rate

Logix Connections Number of Nodes

1756-CN2B ControlNet bridge standard media 5 Mbps 128(1) 99

1756-CN2RB ControlNet bridge redundant media 5 Mbps 128(1) 99

1756-CNB ControlNet bridge standard media 5 Mbps 64(2) 99

1756-CNBR ControlNet bridge redundant media 5 Mbps 64(2) 99

1756-CN2RXT ControlLogix-XT extended temperature ControlNet bridge redundant media

5 Mbps 128(1) 99

(1) 128 connections are available for standard use An additional three connections are reserved for redundant control

(2) Recommend using only 4048 Logix connections for IO

20 Publication 1756-SG001P-EN-P - May 2011

Example Configuration - ControlNet Network

Example Configuration - Redundant ControlNet Media

For information on ControlNet media see ControlNet Media System Components List AG-PA002

DeviceNet Communication Module

The DeviceNet network provides connections between simple industrial devices (such as sensors and actuators) and higher-level devices (such as controllers and computers)

1784-U2CNPanelView Plus

1788-CN2DN

DeviceNetPowerFlex 700SPLC-540CControlLogix

Redundant Media

ControlLogix1756-CNBR

ControlNet Node

ControlNet Node

Cat No Description Communication Rate Number of Nodes

1756-DNB DeviceNet bridge 125 Kbps (500 m max)250 Kbps (250 m max)500 Kbps (100 m max)

64

Publication 1756-SG001P-EN-P - May 2011 21

Example Configuration - DeviceNet Network

Accessories - DeviceNet Network

PLC-51771-SDN ControlLogix

1756-DNB

Ultra3000

PanelView Plus1784-U2DN

Ultra5000

IO

Motor starter

PowerFlex AC

Sensor Pushbuttons

LightsBar Code Scanner

Cat No Description

KwikLink Lite flat media KwikLink Lite flat media is a newer ODVA-approved solution for wiring DeviceNet networks Drop-lines for connecting nodes are added by using the KwikLink Lite two-piece connectors This cable system supports the intermixing of DeviceNet cable types (thin-round with flat) All of the KwikLink Lite connectors provide insulation displacement technology with reduced assembly time

KwikLink flat media The KwikLink flat media system provides a modular cabling method with its flat 4-wire cable and insulation displacement connectors (IDCs) The KwikLink system allows nodes to be added to the network without severing the trunkline Cutting or stripping of the trunkline is eliminated as is the need for predetermined cable lengths

Round media Round trunk cable is available in bulk spools or as pre-molded cordsets or patchcords in varying lengths A wide variety of rugged durable DeviceNet components is available for use in round trunk systems Stainless steel versions of round cable system components are also available Thick-trunk round media systems use thick cable for maximum DeviceNet trunk line length Round media thin-trunk systems use thin cable to reduce maximum trunk line distances with a more

compact and cost-effective installation for some applications Thin-cable outer jacket material is TPE for additional chemical resistance

22 Publication 1756-SG001P-EN-P - May 2011

Data Highway Plus and Remote IO Communication Modules

The Data Highway Plus network supports messaging between devices The remote IO link connects to remote IO chassis and other intelligent devices

The 1756-DHRIO module supports messaging between devices on DH+ networks The remote IO functionality enables the module to act as a scanner for transferring digital and block-transfer data to and from remote IO devices

The 1756-RIO module can act as a scanner or adapter on a remote IO network In addition to digital and block-transfer data the 1756-RIO module transfers analog and specialty data without message instructions

Cat No Description Communication Rate DH+ Connections RIO Connections Maximum Recommended Logix Connections

1756-DHRIO Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

1756-RIO Remote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

mdash Remote IO scanner or adapter32 physical racks (076) any combination of rack size and block transfers

10 scheduled IO

1756-DHRIOXT ControlLogix-XT extended temperature Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

Publication 1756-SG001P-EN-P - May 2011 23

Example Configuration - DH+ Network

Example Configuration - Remote IO Network

Accessories - DH+ and Remote IO Networks

PanelView Plus

PLC-5 1784-U2DHPRSLogix 5000

ControlLogix1756-DHRIO

SLC 504

PanelView PlusPLC-5

1791 IO1794 IO

1756-RIO as a Remote IO Adapter

1756-DHRIO as a Remote IO Scanner

Cat No Description Specifications

1770-CD Cable to connect communication module to DH+ network Belden 9463 twinaxial

9300-RADKIT Remote access dial-in kit 56 Kbps modem connection to devices on a DH+ network includes pre-configured modem communication module DIN rail mounting hardware associated cables

24 Publication 1756-SG001P-EN-P - May 2011

FOUNDATION Fieldbus Linking Devices

The FOUNDATION Fieldbus protocol is a network designed for distributed control of process applications

Example Configuration - Bridge to EtherNetIP Network

Cat No Description Communication Rate Number of H1 Ports

Devices per H1 Link

Devices per Linking Device

1757FFLD2 FOUNDATION Fieldbus bridge to an Ethernet network

FOUNDATION Fieldbus 3125 KbpsEtherNetIP 10100 Mbps

2 16(8hellip10 recommended)

32

1757-FFLD4 4 64

1757-FFLDC2 FOUNDATION Fieldbus bridge to a ControlNet network

FOUNDATION Fieldbus 3125 KbpsControlNet 5 Mbps

2 16(8hellip10 recommended)

32

1757-FFLDC4 4 64

FactoryTalk View SERSFieldbusRSLogix 5000

1757-FFLD4

H1(1)

H1(2)H1(3)H1(4)

HSEIP

Publication 1756-SG001P-EN-P - May 2011 25

Example Configuration - Bridge to ControlNet Network

Other Connectivity Options

ControlLogix RedundancyFactoryTalk View SERSFieldbusRSLogix 5000

ControlNet Redundant Media

1757-FFLDC2

FF H1

EtherNetIP

Option Consideration

USB connection The 1756-L7x controller has a USB port in place of the serial port If your application requires RS-232 functionality see the many Encompass partners at httpwwwrockwellautomationcomencompass

Serial connection The serial port on the 1756-L6x controller is compatible with RS-232 serial communication The serial port supports the DF1 protocol to communicate with other devices on the serial linkTo use Logix5000 controllers on Modbus you connect through the serial port and execute a specific ladder logic routine The controller project is available with RSLogix 5000 Enterprise programming software For more information see Using Logix5000 Controllers as Masters or Slaves on Modbus Application Solution publication CIG-AP129

DH-485 network The controller serial port is compatible with DH-485 communication The DH-485 connection does support remote programming and monitoring via RSLogix 5000 softwareOr add a DH-485 communication bridge module (cat no 1756-DH485)

SynchLink network The SynchLink communication module (1756-SYNCH) provides time synchronization and data broadcasting capabilities for distributed motion and coordinated drive control The module connects a ControlLogix chassis to a SynchLink fiber-optic communication link

26 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Controllers The ControlLogix controller provides a scalable controller solution that is capable of addressing a large amount of IO points

The controller can be placed into any slot of a ControlLogix chassis and multiple controllers can be installed in the same chassis Multiple controllers in the same chassis communicate with each other over the backplane (just as controllers can communicate over networks) but operate independently

ControlLogix controllers can monitor and control IO across the ControlLogix backplane as well as over IO links ControlLogix controllers can communicate over EtherNetIP ControlNet DeviceNet DH+ Remote IO and RS-232-C (DF1DH-485 protocol) networks and many third party process and device networks To provide communication for a ControlLogix controller install the appropriate communication interface module into the chassis

For detailed specifications see 1756 ControlLogix Controllers Specifications publication 1756-TD001

Cat No Description User Memory

1756-L72 ControlLogix controller 1 built-in USB port 4 MB

1756-L73 8 MB

1756-L74 16 MB

1756-L75 32 MB

1756-L61 ControlLogix controller 1 built-in RS-232 port 2 MB

1756-L62 4 MB

1756-L63 8 MB

1756-L64 16 MB

1756-L65 32 MB

1756-L61S GuardLogix safety controller 2 MB standard1 MB safety

1756-L62S 4 MB standard1 MB safety

1756-L63S 8 MB standard375 MB safety

1756-LSP GuardLogix safety partner (one is required for each GuardLogix controller) mdash

1756-L63XT ControlLogix-XT controller extreme environment 8 MB

IMPORTANT Scan time for a project loaded in a 1756-L64 or 1756-L65 controller may be slower than for the same project loaded in one of the other 1756-L6x controllers See the Logix5000 Controllers Instruction Execution Time and Memory Use Reference Manual publication 1756-RM087 for instruction execution times

Publication 1756-SG001P-EN-P - May 2011 27

Standard ControlLogix Controllers

The ControlLogix controller is part of the Logix5000 family of controllers A ControlLogix system includes the following

The ControlLogix controller available in different combinations of user memory

RSLogix 5000 programming software 1756 ControlLogix IO modules that reside in a 1756 chassis Separate communication modules for network communication

Features - Standard ControlLogix Controllers

Feature 1756-L61 1756-L62 1756-L63 1756-L64 1756-L65

1756-L72 1756-L73 1756-L74 1756-L75

Controller tasks 32 tasks 100 programstask Event tasks all event triggers

Built-in communication ports 1 port RS-232 serial 1 port USB

Communication options EtherNetIP ControlNet DeviceNet Data Highway Plus Remote IO SynchLink Third-party process and device networks

Built-in port Serial USB

Controller connections supported max 250 500

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Full support

Integrated motion EtherNetIP connection SERCOS interface Analog options (encoder input LDT input SSI input)

Programming languages Relay ladder Structured text Function block SFC

28 Publication 1756-SG001P-EN-P - May 2011

GuardLogix Controllers

A GuardLogix controller is a ControlLogix controller that also provides safety control The GuardLogix system is a dual controller solutionmdashyou must use a 1756-L6xS primary controller and a 1756-LSP safety partner to achieve SIL 3CAT 4

During development safety and standard have the same rules multiple programmers online editing and forcing are all allowed Once the project is tested and ready for final validation you set the Safety Task to a SIL 3 integrity level which is then enforced by the GuardLogix controller When safety memory is locked and protected the safety logic cant be modified and all safety functions operate with SIL 3 integrity On the standard side of the GuardLogix controller all functions operate like a regular Logix controller

Use Guard IO modules for field device connectivity on Ethernet or DeviceNet networks and for safety interlocking between GuardLogix controllers use Ethernet or ControlNet networks Multiple GuardLogix controllers can share safety data for zone to zone interlocking or a single GuardLogix controller can use remote distributed safety IO between different cellsareas

In addition to the standard features of a ControlLogix controller the GuardLogix controller has these safety-related features

Application Description

SIL 1 2 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508 and applications up to and including PLeCat4 according to ISO 13849-1 For more information see GuardLogix Controllers Systems Safety Reference Manual publication 1756-RM093 GuardLogix Controllers User Manual publication 1756-UM020 GuardLogix Safety Application Instruction Set Reference Manual publication 1756-RM095

Features - GuardLogix Controllers

Feature 1756-L61S 1756-L62S 1756-L63S 1756-LSP

Safety communication options Standard and safety EtherNetIP ControlNet DeviceNet

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Not supported

Programming languages Relay ladder

Publication 1756-SG001P-EN-P - May 2011 29

ControlLogix-XT Controllers

The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh corrosive environments

When used with FLEX IO-XT products the ControlLogix-XT system can withstand temperatures range from -2070 C (-4158 F)

When used independently the ControlLogix-XT system can withstand temperature ranges from -2570 C (-13158 F)

Redundant ControlLogix Controllers

The ControlLogix controller supports controller redundancy In a redundant controller system you need these components

Two 1756 chassis each with the following the same ndash Number of slots

ndash Modules in the same slots

ndash Redundancy firmware revisions in each module

ndash Two additional ControlNet nodes outside the redundant chassis pair

You need one of these redundancy modules

One 1756-RM module per chassis that supports the followingndash Two 1756-L61 1756-L62 1761-L63 controllers or one 1756-L64

controller

ndash Maximum of seven communication modules which can be 1756-CN2 series B 1756-CN2R series B and 1756-EN2T modules

ndash One 1756-RMCx cable

One 1757-SRM module per chassis that supports the followingndash One 1756-L61 1756-L62 1756-L63 1756-L64 controller

ndash Maximum of seven communication modules which can be 1756-CNB series D or E 1756-CNBR series D or E 1756-ENBT and 1756-EWEB modules

ndash One 1757-SRCx cable

30 Publication 1756-SG001P-EN-P - May 2011

Accessories - Controllers

Memory Cards

Memory cards offer nonvolatile memory to permanently store a user program and tag data on a controller The 1756-L7x ControlLogix controller comes with 1784-SD1 Secure Digital (SD) card already installed The 1756-L6x controllers support optional CompactFlash cards that you purchase separately The memory card installs in a socket on the controller Through RSLogix 5000 software you can manually trigger the controller to save to or load from nonvolatile memory or configure the controller to load from nonvolatile memory on powerup

The GuardLogix controller does not support user program storage or retrieval by using a CompactFlash card

1756 Energy Storage Modules

Instead of a battery the 1756-L7x controller ships with a 1756-ESMCAP energy storage module (ESM) already installed

Attribute 1784-CF64 1784-CF128 1784-SD1 1784-SD2

Memory 64 MB 128 MB 1 GB 2 GB

Supported controllers 1756-L6x 1756-L7x

Weight approx 142 g (05 oz) 176 g (0062 oz)

Cat No Description

1756-ESMCAP Capacitor-based energy-storage module Comes with the controller

1756-EMNSE ESM without WallClockTime backup power Additionally you can use this ESM with a 1756-L73 (8 MB) or smaller memory-sized controller only

Use this ESM if your application requires that the installed ESM deplete its residual energy to 40 microJoule or less before transporting it into or out of your application

1756-ESMNRM Energy-storage module that secures the controller by preventing the USB connection and SD card useThis ESM provides your application an enhanced degree of security

Publication 1756-SG001P-EN-P - May 2011 31

1756 ControlLogix Batteries

Each 1756-L6x controller ships with a battery With a memory card installed the controller can be used without a battery If you do not use a battery current tag data will be at the state it was when the memory card was saved

ControlLogix Chassis The ControlLogix system is a modular system that requires a 1756 IO chassis Place any module into any slot The backplane provides a high-speed communication path between modules

All of the chassis are designed for horizontal-only back-panel mounting The chassis are available in these configurations

Standard chassis ControlLogix-XT chassis

For detailed specifications see 1756 ControlLogix Chassis Specifications Specifications publication 1756-TD006

Features - Chassis

Slot guides and snap-in retention for easy and secure module fit for any type of 1756 module

Direct mounting accommodates any 1756 power supply

Attribute 1756-BA1 1756-BA2 1756-BATM(1) 1756-BATA

Description Lithium battery (059 g) Lithium battery (059 g) Externally mounted battery assembly

Replacement lithium battery for 1756-BATM (5 g max lithium per each D cell contains 2 D cells)

ControlLogix controllers 1756-L61 1756-L62 1756-L63 series A

1756-L61 1756-L62 1756-L63 series B1756-L64 1756-L65

1756-L61 1756-L62 1756-L63 series A

1756-BATM battery module

GuardLogix controllers mdash 1756-L61S 1756-L62S 1756-L63S

mdash mdash

ControlLogix-XT controllers

mdash 1756-L63XT mdash mdash

(1) The 1756-BATM externally mounted battery assembly is highly recommended for use with all series A 1756-L6x controllers and provides longer battery life than the 1756-BA1 battery The 1756-BATM includes one 1756-BATA lithium battery assembly and a 1 m (328 ft) cable to connect housing to controller

32 Publication 1756-SG001P-EN-P - May 2011

Standard Chassis

The chassis backplane provides a high-speed communication path between modules and distributes power to each of the modules within the chassis

ControlLogix-XT Chassis

The ControlLogix-XT chassis support extreme temperature environments

Accessories - Chassis

Use a slot filler module to fill empty slots

Cat No Description Slots

1756-A4 ControlLogix standard chassis 4

1756-A7 7

1756-A10 10

1756-A13 13

1756-A17 17

Cat No Description Slots Temperature Range

1756-A4LXT ControlLogix-XT chassis 4 -2560 degC (-13140 degF)

1756-A5XT 5 -2570 degC (-13158 degF)

1756-A7LXT 7 -2560 degC (-13140 degF)

Cat No Description

1756-N2 Slot filler module for empty slots in standard ControlLogix chassis

1756-N2XT Slot filler module for empty slots in ControlLogix-XT chassis

Publication 1756-SG001P-EN-P - May 2011 33

ControlLogix Power Supplies

ControlLogix power supplies are used with the 1756 chassis to provide 12V 33V 5V and 24V DC power directly to the chassis backplane Select from these configurations

Standard power Redundant power ControlLogix-XT power

For detailed specifications see 1756 ControlLogix Power Supplies Specifications publication 1756-TD005

Standard Power Supplies

You mount a standard power supply directly on the left end of the chassis where it plugs directly into the backplane

ControlLogix-XT Power Supplies

The ControlLogix-XT power supplies support extreme temperature environments

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA72 ControlLogix standard AC 120V220V AC 85hellip265V AC Standard series A and series B

1756-PA75 120V220V AC 85hellip265V AC Standard series B

1756-PB72 ControlLogix standard DC 24V DC 18hellip32V DC Standard series A and series B

1756-PB75 24V DC 1832V DC Standard series B

1756-PC75 48V DC 30hellip60V DC Standard series B

1756-PH75 125V DC 90hellip143V DC Standard series B

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PAXT ControlLogix-XT AC power supply 85265V AC 120240V AC XT

1756-PBXT ControlLogix-XT DC power supply 24V DC 18hellip32V DC XT

34 Publication 1756-SG001P-EN-P - May 2011

Redundant Power Supplies

To build a redundant power supply system you need the following

Two redundant power supplies (both 1756-PA75R or 1756-PB75R) One 1756-PSCA2 chassis adapter module Two 1756-CPR2 cables to connect the power supplies to the

1756-PSCA2 chassis adapter module (091 m (3 ft) length) User-supplied annunciator wiring to connect the power supplies to the

input modules as needed

The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Accessories - Redundant Power Supplies

Visualization Products Visualization products together with Logix for control and NetLinx architecture for communication make up the Rockwell Automation Integrated Architecture strategy The visualization strategy combines Rockwell Automation expertise in Allen-Bradley electronic operator interface and industrialized personal computer hardware with Rockwell Software supervisory control software Current visualization products include the following

FactoryTalk View software PanelView Plus operator interface PanelView Plus CE operator interface Industrial computers and monitors

For more information see the Operator Interface catalog pages at httpwwwabcomenepubcatalogs1276221813761239781

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA75R ControlLogix redundant 120V220V AC 85hellip265V AC Standard series B

1756-PB75R 24V DC 192hellip32V DC Standard series B

Cat No Description Specifications

1756-PSCA2 Chassis adapter module Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Mounts directly to left side of 1756 chassis

1756-CPR2 Chassis adapter cable Connects redundant power supply to 1756-PCSA2 chassis adapter Length091 m (3 ft)

Publication 1756-SG001P-EN-P - May 2011 35

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN ltFEFF9ad854c18cea51fa529b7528002000410064006f0062006500200050004400460020658766f8306e4f5c6210306b4f7f75283057307e30593002537052376642306e753b8cea3092670059279650306b4fdd306430533068304c3067304d307e3059300230c730b930af30c830c330d730d730ea30f330bf3067306e53705237307e305f306f30d730eb30fc30d57528306b9069305730663044307e305930023053306e8a2d5b9a30674f5c62103055308c305f0020005000440046002030d530a130a430eb306f3001004100630072006f0062006100740020304a30883073002000410064006f00620065002000520065006100640065007200200035002e003000204ee5964d3067958b304f30533068304c3067304d307e30593002gt KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE ltFEFF0041006e007600e4006e00640020006400650020006800e4007200200069006e0073007400e4006c006c006e0069006e006700610072006e00610020006f006d002000640075002000760069006c006c00200073006b006100700061002000410064006f006200650020005000440046002d0064006f006b0075006d0065006e00740020006600f600720020006b00760061006c00690074006500740073007500740073006b0072006900660074006500720020007000e5002000760061006e006c00690067006100200073006b0072006900760061007200650020006f006300680020006600f600720020006b006f007200720065006b007400750072002e002000200053006b006100700061006400650020005000440046002d0064006f006b0075006d0065006e00740020006b0061006e002000f600700070006e00610073002000690020004100630072006f0062006100740020006f00630068002000410064006f00620065002000520065006100640065007200200035002e00300020006f00630068002000730065006e006100720065002egt ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

Analog Combination Input and Output Module

Specialty IO Modules

Cat No InputsOutputs Range Resolution Removable Terminal Block

1756-IF4FXOF2F 4 high-speed sub-millisecond differential inputs2 high-speed voltage or current outputs

Inputplusmn105V0hellip105V0hellip525V0hellip21 mAOutputplusmn104V0hellip21 mA

InputApprox 14 bits across plusmn10V DC (21V total)plusmn10V 13 mVbit 14-bit effective0hellip105V 13 mVbit 13-bit effective0hellip525V 13 mVbit 12-bit effectiveApprox 12 bits across 21 mA0hellip21 mA 525 AbitOutput13 bits across 21 mA = 28 Abit14 bits across 218V = 13 mVbit

1756-TBCH1756-TBS6H

Cat No InputsOutputs Description Removable Terminal Block

1756-CFM 4 inputs (2 per channel) 2 outputs current sourcing

Configurable flowmeter module2 Flowmeter (F) inputs used for all modes2 Gate inputs used in Totalizer mode for proverstore count

1756-TBNH1756-TBSH

1756-HSC 2 counters each with 3 inputs (A B Z for gatereset)4 outputs (2 pointsgroup)

High-speed counter module5V operation 45hellip55V DC1224V operation 10hellip312V DC

1756-TBCH1756-TBS6H

1756-PLS Left section 2 groups of 4 outputs and 4 inputs eachCenter section resolver interface and IO controlRight section 2 groups of 4 outputs and 4 inputs each

Programmable limit switch module Requires 3 RTBs 1756-TBNH or 1756-TBSH

12 Publication 1756-SG001P-EN-P - May 2011

HART Smart Instrumentation

HART (Highway Addressable Remote Transmitter) is an open protocol designed to connect analog devices For HART connectivity select from products available from Rockwell Automation and our Encompass partners

Typical HART Configuration

HART Interfaces

Accessories - IO Modules

1756 Removable Terminal Blocks

Removable terminal blocks (RTBs) provide a flexible interconnection between your plant wiring and 1756 IO modules The RTB plugs into the front of the IO module The type of module determines which RTB you need You can choose screw-clamp or spring-clamp RTBs

RTBs are not shipped with IO modules You must order them separately The standard housing on the front of the wiring arm is not deep enough for 25 mm2

HART Devices

ControlLogix Controller with 1756-IF8H or 1756-OF8H module

If your application has Select Description

Analog and HART connectivity in one moduleNo external hardware required to access HART signalHART commands can be transmitted as unscheduled messagesSupports asset management software to HART device

1756-IF8H1756-IF16H1756-OF8H

Rockwell Automation analog IO modules

Data acquisition or control application with slow update requirements (such as a tank farm)No external hardware required to access HART signalDoes not connect directly to asset management software

MVI56-HART Prosoft interface

Analog and HART in one moduleInstrumentation in hazardous locations (FLEX Ex modules)HART commands can be transmitted as unscheduled messagesDirectly connects asset management software to HART devices

1794 FLEX IO1797 FLEX Ex IO

There are specific FLEX IO and FLEX Ex modules designed for HART systems These catalog numbers end in an H such as 1797-IE8H

Publication 1756-SG001P-EN-P - May 2011 13

(14 AWG) wiring If you plan to use 25 mm2 (14 AWG) wiring also order the extended housing

Wiring Systems

As an alternative to buying RTBs and connecting the wires yourself you can buy a wiring system of the following

Interface modules (IFMs) that provide the output terminal blocks for digital IO modules Use the pre-wired cables that match the IO module to the IFM

Analog interface modules (AIFMs) that provide the output terminal blocks for analog IO modules Use the pre-wired cables that match the IO module to the AIFM

IO module-ready cables One end of the cable assembly is an RTB that plugs into the front of the IO module The other end has individually color-coded conductors that connect to a standard terminal block

Attribute 1756-TBNH 1756-TBSH 1756-TBCH 1756-TBS6H 1756-TBE

Description 20-position NEMA screw-clamp removable block

20-pin spring-clamp removable terminal block with standard housing

36-pin cage-clamp removable terminal block with standard housing

36-pin spring-clamp removable terminal block with standard housing

Extended depth terminal block housing

Screw torque 08hellip1 Nbullm7hellip9 lbbullin

04 Nbullm44 lbbullin

mdash

Screwdriver width 8 mm (516 in) max

IO Module

RTBPre-wired Cable

Factory-wired

Interface Module (IFM)

Field Wiring

14 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Integrated Motion

The Logix architecture supports motion control components that work in a wide variety of machine architectures

Integrated motion on EtherNetIP supports a connection to Ethernet drives

The Kinetix integrated-motion solution uses a SERCOS interface module to perform multi-axis synchronized motion

Logix integrated motion supports the analog family of servo modules for controlling drivesactuators

Networked motion provides the ability to connect via the DeviceNet network to a single axis drive to perform point-to-point indexing

For detailed specifications on motion interface modules see 1756 ControlLogix Integrated Motion Specifications publication 1756-TD004

For more information see these publications

Motion Analyzer CD to size your motion application and to make final component selection Download the software from httpwwwabcommotionsoftwareanalyzerhtml

Kinetix Motion Control Selection Guide publication GMC-SG001 to verify drive motor and accessory specifications

Integrated Motion on an EtherNetIP Network

Product Consideration

Drive that supports EtherNetIP connections Unlimited velocity torque and Vhz configured drives Kinetix 6500 drives PowerFlex 755 drives

ControlLogix controller As many as 100 drives per controller

ControlLogix EtherNetIP communication module 1hellip8 position configured drives with 1756-EN2TR module 1hellip255 position configured drives with 1756-EN3TR module

Publication 1756-SG001P-EN-P - May 2011 15

SERCOS Interface Modules

The SERCOS interface modules can connect to these servo drives

2093 Kinetix 2000 multi-axis servo drive 2094 Kinetix 6000 multi-axis servo drive 2099 Kinetix 7000 high-power servo drive 2098 Ultra3000 SERCOS servo drive

ControlLogix Controller

PanelView Plus Terminal

Workstations

POINT IO ModulesDrive with EtherNetIP Connection

Cat No Description Number of Axis

1756-M16SE Rockwell Automation SERCOS interface modules 16

1756-M08SE 8

1756-M03SE 3

1756-M08SEG SERCOS interface drives that are Extended Pack Profile compliant 8

16 Publication 1756-SG001P-EN-P - May 2011

Analog Motion Interface Modules

RSLogix 5000 Software1756-MxxSE Module

ControlLogix Controller

Three-phase Input Power

Line Interface Module

Integrated Axis Module

Motor Motor Feedback

Axis Modules

Slot Filler Module

Shunt Module

SERCOS Fiber-optic RingKinetix 6000 Multi-axis Servo Drive

Cat No Description Number of Axis

1756-M02AE Analog servo interface drives with quadrature feedback 2

1756-HYD02 Analog hydraulic servo interface drives LDT feedback 2

1756-M02AS Analog servo interface drives with SSI feedback 2

Publication 1756-SG001P-EN-P - May 2011 17

ControlLogix Communication Modules

Separate communication modules are available for different networks Install multiple communication modules into the ControlLogix backplane to bridge or route control and information data between different networks You can route a message through a maximum of four chassis (eight communication hops) You do not need a ControlLogix controller in the chassis

For detailed specifications see 1756 ControlLogix Network Specifications publication 1756-TD003

Application Network Page

Plant management (material handling) Configuration data collection and control on a single high-speed network Time-critical applications with no established schedule Inclusion of commercial technologies (such as video over IP) InternetIntranet connection Integrated CIP motion and safety

EtherNetIP network 19

High-speed transfer of time-critical data between controllers and IO devices Deterministic and repeatable data delivery Media redundancy Intrinsic safety Redundant controller systems

ControlNet network 20

Connections of low-level devices directly to plant floor controllers without interfacing them through IO modules

Data sent as needed More diagnostics for improved data collection and fault detection Less wiring and reduced start-up time than a traditional hard-wired system

DeviceNet network 21

Plant-wide and cell-level data sharing with program maintenance Data sent regularly Transfer of information between controllers

Data Highway Plus network 23

Connections between controllers and IO adapters Data sent regularly Distributed control so that each controller has its own IO and communicates with a

supervisory controller

Remote IO network 23

Fieldbus transmitters and actuators Closed-loop control Process automation

Foundation Fieldbus network 25

18 Publication 1756-SG001P-EN-P - May 2011

EtherNetIP Communication Modules

The Ethernet Industrial (EtherNetIP) network protocol is an open industrial-networking standard that supports both real-time IO messaging and message exchange The EtherNetIP network uses off-the-shelf Ethernet communication chips and physical media

Accessories - EtherNetIP Network

Cat No Description Media Communication Rate

CIP Motion Axes max

TCPIP Connections

Logix Connections

1756-EN2F EtherNetIP bridge fiber Fiber 100 Mbps 8 128 256

1756-EN2T EtherNetIP bridge copper Copper 10100 Mbps 8 128 256

1756-EN2TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 8 128 256

1756-EN3TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 255 128 256

1756-ENBT EtherNetIP bridge copper Copper 10100 Mbps mdash 64 128

1756-EWEB Ethernet web server module Copper 10100 Mbps mdash 64 128

1756-EN2TXT ControlLogix-XT extended temperature EtherNetIP bridge copper for extreme environments

Copper 10100 Mbps 8 128 256

Cat No Description Specifications

1585J-M8PBJM-x Ethernet RJ45 patchcordx = 2 (2 m) 5 (5 m) or 10 (10 m)

8-conductor Teal Riser PVC Cable (Flex Rated cable also available)

1585J-M8CC-H RJ45 insulation displacement connector (IDC) 01280325 mm2 (26hellip22 AWG) Cat 6 IDC no tool required

1585J-M8CC-C RJ45 crimp connector with boot qty = 50 pieces 01280205 mm2 (26hellip24 AWG Cat 5e requires crimp tool for assembly

1585A-Jcrimp Crimp tool mdash

9300-RADES Remote access dial-in kit 56 Kbps modem connection to devices on an Ethernet network includes pre-configured modem communication module DIN rail mounting hardware associated cables

Publication 1756-SG001P-EN-P - May 2011 19

Example Configuration - EtherNetIP Network

ControlNet Communication ModulesThe ControlNet network combines the functionality of an IO network and a peer-to-peer network providing high-speed performance The ControlNet network provides deterministic repeatable transfers of critical control data

FirewallRouter

Stratix Switch

Stratix Switch

Stratix Switch

Powermonitor 3000PowerFlex 70

Ethernet PLC-5

MicroLogix

Ethernet SLC 500

1756 IO

1794 IO

1761-NET-ENI

ControlNet

DeviceNet

1734 IO

RSLinxPanelView Plus

1769-L35E CompactLogix

Cat No Description Communication Rate

Logix Connections Number of Nodes

1756-CN2B ControlNet bridge standard media 5 Mbps 128(1) 99

1756-CN2RB ControlNet bridge redundant media 5 Mbps 128(1) 99

1756-CNB ControlNet bridge standard media 5 Mbps 64(2) 99

1756-CNBR ControlNet bridge redundant media 5 Mbps 64(2) 99

1756-CN2RXT ControlLogix-XT extended temperature ControlNet bridge redundant media

5 Mbps 128(1) 99

(1) 128 connections are available for standard use An additional three connections are reserved for redundant control

(2) Recommend using only 4048 Logix connections for IO

20 Publication 1756-SG001P-EN-P - May 2011

Example Configuration - ControlNet Network

Example Configuration - Redundant ControlNet Media

For information on ControlNet media see ControlNet Media System Components List AG-PA002

DeviceNet Communication Module

The DeviceNet network provides connections between simple industrial devices (such as sensors and actuators) and higher-level devices (such as controllers and computers)

1784-U2CNPanelView Plus

1788-CN2DN

DeviceNetPowerFlex 700SPLC-540CControlLogix

Redundant Media

ControlLogix1756-CNBR

ControlNet Node

ControlNet Node

Cat No Description Communication Rate Number of Nodes

1756-DNB DeviceNet bridge 125 Kbps (500 m max)250 Kbps (250 m max)500 Kbps (100 m max)

64

Publication 1756-SG001P-EN-P - May 2011 21

Example Configuration - DeviceNet Network

Accessories - DeviceNet Network

PLC-51771-SDN ControlLogix

1756-DNB

Ultra3000

PanelView Plus1784-U2DN

Ultra5000

IO

Motor starter

PowerFlex AC

Sensor Pushbuttons

LightsBar Code Scanner

Cat No Description

KwikLink Lite flat media KwikLink Lite flat media is a newer ODVA-approved solution for wiring DeviceNet networks Drop-lines for connecting nodes are added by using the KwikLink Lite two-piece connectors This cable system supports the intermixing of DeviceNet cable types (thin-round with flat) All of the KwikLink Lite connectors provide insulation displacement technology with reduced assembly time

KwikLink flat media The KwikLink flat media system provides a modular cabling method with its flat 4-wire cable and insulation displacement connectors (IDCs) The KwikLink system allows nodes to be added to the network without severing the trunkline Cutting or stripping of the trunkline is eliminated as is the need for predetermined cable lengths

Round media Round trunk cable is available in bulk spools or as pre-molded cordsets or patchcords in varying lengths A wide variety of rugged durable DeviceNet components is available for use in round trunk systems Stainless steel versions of round cable system components are also available Thick-trunk round media systems use thick cable for maximum DeviceNet trunk line length Round media thin-trunk systems use thin cable to reduce maximum trunk line distances with a more

compact and cost-effective installation for some applications Thin-cable outer jacket material is TPE for additional chemical resistance

22 Publication 1756-SG001P-EN-P - May 2011

Data Highway Plus and Remote IO Communication Modules

The Data Highway Plus network supports messaging between devices The remote IO link connects to remote IO chassis and other intelligent devices

The 1756-DHRIO module supports messaging between devices on DH+ networks The remote IO functionality enables the module to act as a scanner for transferring digital and block-transfer data to and from remote IO devices

The 1756-RIO module can act as a scanner or adapter on a remote IO network In addition to digital and block-transfer data the 1756-RIO module transfers analog and specialty data without message instructions

Cat No Description Communication Rate DH+ Connections RIO Connections Maximum Recommended Logix Connections

1756-DHRIO Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

1756-RIO Remote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

mdash Remote IO scanner or adapter32 physical racks (076) any combination of rack size and block transfers

10 scheduled IO

1756-DHRIOXT ControlLogix-XT extended temperature Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

Publication 1756-SG001P-EN-P - May 2011 23

Example Configuration - DH+ Network

Example Configuration - Remote IO Network

Accessories - DH+ and Remote IO Networks

PanelView Plus

PLC-5 1784-U2DHPRSLogix 5000

ControlLogix1756-DHRIO

SLC 504

PanelView PlusPLC-5

1791 IO1794 IO

1756-RIO as a Remote IO Adapter

1756-DHRIO as a Remote IO Scanner

Cat No Description Specifications

1770-CD Cable to connect communication module to DH+ network Belden 9463 twinaxial

9300-RADKIT Remote access dial-in kit 56 Kbps modem connection to devices on a DH+ network includes pre-configured modem communication module DIN rail mounting hardware associated cables

24 Publication 1756-SG001P-EN-P - May 2011

FOUNDATION Fieldbus Linking Devices

The FOUNDATION Fieldbus protocol is a network designed for distributed control of process applications

Example Configuration - Bridge to EtherNetIP Network

Cat No Description Communication Rate Number of H1 Ports

Devices per H1 Link

Devices per Linking Device

1757FFLD2 FOUNDATION Fieldbus bridge to an Ethernet network

FOUNDATION Fieldbus 3125 KbpsEtherNetIP 10100 Mbps

2 16(8hellip10 recommended)

32

1757-FFLD4 4 64

1757-FFLDC2 FOUNDATION Fieldbus bridge to a ControlNet network

FOUNDATION Fieldbus 3125 KbpsControlNet 5 Mbps

2 16(8hellip10 recommended)

32

1757-FFLDC4 4 64

FactoryTalk View SERSFieldbusRSLogix 5000

1757-FFLD4

H1(1)

H1(2)H1(3)H1(4)

HSEIP

Publication 1756-SG001P-EN-P - May 2011 25

Example Configuration - Bridge to ControlNet Network

Other Connectivity Options

ControlLogix RedundancyFactoryTalk View SERSFieldbusRSLogix 5000

ControlNet Redundant Media

1757-FFLDC2

FF H1

EtherNetIP

Option Consideration

USB connection The 1756-L7x controller has a USB port in place of the serial port If your application requires RS-232 functionality see the many Encompass partners at httpwwwrockwellautomationcomencompass

Serial connection The serial port on the 1756-L6x controller is compatible with RS-232 serial communication The serial port supports the DF1 protocol to communicate with other devices on the serial linkTo use Logix5000 controllers on Modbus you connect through the serial port and execute a specific ladder logic routine The controller project is available with RSLogix 5000 Enterprise programming software For more information see Using Logix5000 Controllers as Masters or Slaves on Modbus Application Solution publication CIG-AP129

DH-485 network The controller serial port is compatible with DH-485 communication The DH-485 connection does support remote programming and monitoring via RSLogix 5000 softwareOr add a DH-485 communication bridge module (cat no 1756-DH485)

SynchLink network The SynchLink communication module (1756-SYNCH) provides time synchronization and data broadcasting capabilities for distributed motion and coordinated drive control The module connects a ControlLogix chassis to a SynchLink fiber-optic communication link

26 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Controllers The ControlLogix controller provides a scalable controller solution that is capable of addressing a large amount of IO points

The controller can be placed into any slot of a ControlLogix chassis and multiple controllers can be installed in the same chassis Multiple controllers in the same chassis communicate with each other over the backplane (just as controllers can communicate over networks) but operate independently

ControlLogix controllers can monitor and control IO across the ControlLogix backplane as well as over IO links ControlLogix controllers can communicate over EtherNetIP ControlNet DeviceNet DH+ Remote IO and RS-232-C (DF1DH-485 protocol) networks and many third party process and device networks To provide communication for a ControlLogix controller install the appropriate communication interface module into the chassis

For detailed specifications see 1756 ControlLogix Controllers Specifications publication 1756-TD001

Cat No Description User Memory

1756-L72 ControlLogix controller 1 built-in USB port 4 MB

1756-L73 8 MB

1756-L74 16 MB

1756-L75 32 MB

1756-L61 ControlLogix controller 1 built-in RS-232 port 2 MB

1756-L62 4 MB

1756-L63 8 MB

1756-L64 16 MB

1756-L65 32 MB

1756-L61S GuardLogix safety controller 2 MB standard1 MB safety

1756-L62S 4 MB standard1 MB safety

1756-L63S 8 MB standard375 MB safety

1756-LSP GuardLogix safety partner (one is required for each GuardLogix controller) mdash

1756-L63XT ControlLogix-XT controller extreme environment 8 MB

IMPORTANT Scan time for a project loaded in a 1756-L64 or 1756-L65 controller may be slower than for the same project loaded in one of the other 1756-L6x controllers See the Logix5000 Controllers Instruction Execution Time and Memory Use Reference Manual publication 1756-RM087 for instruction execution times

Publication 1756-SG001P-EN-P - May 2011 27

Standard ControlLogix Controllers

The ControlLogix controller is part of the Logix5000 family of controllers A ControlLogix system includes the following

The ControlLogix controller available in different combinations of user memory

RSLogix 5000 programming software 1756 ControlLogix IO modules that reside in a 1756 chassis Separate communication modules for network communication

Features - Standard ControlLogix Controllers

Feature 1756-L61 1756-L62 1756-L63 1756-L64 1756-L65

1756-L72 1756-L73 1756-L74 1756-L75

Controller tasks 32 tasks 100 programstask Event tasks all event triggers

Built-in communication ports 1 port RS-232 serial 1 port USB

Communication options EtherNetIP ControlNet DeviceNet Data Highway Plus Remote IO SynchLink Third-party process and device networks

Built-in port Serial USB

Controller connections supported max 250 500

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Full support

Integrated motion EtherNetIP connection SERCOS interface Analog options (encoder input LDT input SSI input)

Programming languages Relay ladder Structured text Function block SFC

28 Publication 1756-SG001P-EN-P - May 2011

GuardLogix Controllers

A GuardLogix controller is a ControlLogix controller that also provides safety control The GuardLogix system is a dual controller solutionmdashyou must use a 1756-L6xS primary controller and a 1756-LSP safety partner to achieve SIL 3CAT 4

During development safety and standard have the same rules multiple programmers online editing and forcing are all allowed Once the project is tested and ready for final validation you set the Safety Task to a SIL 3 integrity level which is then enforced by the GuardLogix controller When safety memory is locked and protected the safety logic cant be modified and all safety functions operate with SIL 3 integrity On the standard side of the GuardLogix controller all functions operate like a regular Logix controller

Use Guard IO modules for field device connectivity on Ethernet or DeviceNet networks and for safety interlocking between GuardLogix controllers use Ethernet or ControlNet networks Multiple GuardLogix controllers can share safety data for zone to zone interlocking or a single GuardLogix controller can use remote distributed safety IO between different cellsareas

In addition to the standard features of a ControlLogix controller the GuardLogix controller has these safety-related features

Application Description

SIL 1 2 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508 and applications up to and including PLeCat4 according to ISO 13849-1 For more information see GuardLogix Controllers Systems Safety Reference Manual publication 1756-RM093 GuardLogix Controllers User Manual publication 1756-UM020 GuardLogix Safety Application Instruction Set Reference Manual publication 1756-RM095

Features - GuardLogix Controllers

Feature 1756-L61S 1756-L62S 1756-L63S 1756-LSP

Safety communication options Standard and safety EtherNetIP ControlNet DeviceNet

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Not supported

Programming languages Relay ladder

Publication 1756-SG001P-EN-P - May 2011 29

ControlLogix-XT Controllers

The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh corrosive environments

When used with FLEX IO-XT products the ControlLogix-XT system can withstand temperatures range from -2070 C (-4158 F)

When used independently the ControlLogix-XT system can withstand temperature ranges from -2570 C (-13158 F)

Redundant ControlLogix Controllers

The ControlLogix controller supports controller redundancy In a redundant controller system you need these components

Two 1756 chassis each with the following the same ndash Number of slots

ndash Modules in the same slots

ndash Redundancy firmware revisions in each module

ndash Two additional ControlNet nodes outside the redundant chassis pair

You need one of these redundancy modules

One 1756-RM module per chassis that supports the followingndash Two 1756-L61 1756-L62 1761-L63 controllers or one 1756-L64

controller

ndash Maximum of seven communication modules which can be 1756-CN2 series B 1756-CN2R series B and 1756-EN2T modules

ndash One 1756-RMCx cable

One 1757-SRM module per chassis that supports the followingndash One 1756-L61 1756-L62 1756-L63 1756-L64 controller

ndash Maximum of seven communication modules which can be 1756-CNB series D or E 1756-CNBR series D or E 1756-ENBT and 1756-EWEB modules

ndash One 1757-SRCx cable

30 Publication 1756-SG001P-EN-P - May 2011

Accessories - Controllers

Memory Cards

Memory cards offer nonvolatile memory to permanently store a user program and tag data on a controller The 1756-L7x ControlLogix controller comes with 1784-SD1 Secure Digital (SD) card already installed The 1756-L6x controllers support optional CompactFlash cards that you purchase separately The memory card installs in a socket on the controller Through RSLogix 5000 software you can manually trigger the controller to save to or load from nonvolatile memory or configure the controller to load from nonvolatile memory on powerup

The GuardLogix controller does not support user program storage or retrieval by using a CompactFlash card

1756 Energy Storage Modules

Instead of a battery the 1756-L7x controller ships with a 1756-ESMCAP energy storage module (ESM) already installed

Attribute 1784-CF64 1784-CF128 1784-SD1 1784-SD2

Memory 64 MB 128 MB 1 GB 2 GB

Supported controllers 1756-L6x 1756-L7x

Weight approx 142 g (05 oz) 176 g (0062 oz)

Cat No Description

1756-ESMCAP Capacitor-based energy-storage module Comes with the controller

1756-EMNSE ESM without WallClockTime backup power Additionally you can use this ESM with a 1756-L73 (8 MB) or smaller memory-sized controller only

Use this ESM if your application requires that the installed ESM deplete its residual energy to 40 microJoule or less before transporting it into or out of your application

1756-ESMNRM Energy-storage module that secures the controller by preventing the USB connection and SD card useThis ESM provides your application an enhanced degree of security

Publication 1756-SG001P-EN-P - May 2011 31

1756 ControlLogix Batteries

Each 1756-L6x controller ships with a battery With a memory card installed the controller can be used without a battery If you do not use a battery current tag data will be at the state it was when the memory card was saved

ControlLogix Chassis The ControlLogix system is a modular system that requires a 1756 IO chassis Place any module into any slot The backplane provides a high-speed communication path between modules

All of the chassis are designed for horizontal-only back-panel mounting The chassis are available in these configurations

Standard chassis ControlLogix-XT chassis

For detailed specifications see 1756 ControlLogix Chassis Specifications Specifications publication 1756-TD006

Features - Chassis

Slot guides and snap-in retention for easy and secure module fit for any type of 1756 module

Direct mounting accommodates any 1756 power supply

Attribute 1756-BA1 1756-BA2 1756-BATM(1) 1756-BATA

Description Lithium battery (059 g) Lithium battery (059 g) Externally mounted battery assembly

Replacement lithium battery for 1756-BATM (5 g max lithium per each D cell contains 2 D cells)

ControlLogix controllers 1756-L61 1756-L62 1756-L63 series A

1756-L61 1756-L62 1756-L63 series B1756-L64 1756-L65

1756-L61 1756-L62 1756-L63 series A

1756-BATM battery module

GuardLogix controllers mdash 1756-L61S 1756-L62S 1756-L63S

mdash mdash

ControlLogix-XT controllers

mdash 1756-L63XT mdash mdash

(1) The 1756-BATM externally mounted battery assembly is highly recommended for use with all series A 1756-L6x controllers and provides longer battery life than the 1756-BA1 battery The 1756-BATM includes one 1756-BATA lithium battery assembly and a 1 m (328 ft) cable to connect housing to controller

32 Publication 1756-SG001P-EN-P - May 2011

Standard Chassis

The chassis backplane provides a high-speed communication path between modules and distributes power to each of the modules within the chassis

ControlLogix-XT Chassis

The ControlLogix-XT chassis support extreme temperature environments

Accessories - Chassis

Use a slot filler module to fill empty slots

Cat No Description Slots

1756-A4 ControlLogix standard chassis 4

1756-A7 7

1756-A10 10

1756-A13 13

1756-A17 17

Cat No Description Slots Temperature Range

1756-A4LXT ControlLogix-XT chassis 4 -2560 degC (-13140 degF)

1756-A5XT 5 -2570 degC (-13158 degF)

1756-A7LXT 7 -2560 degC (-13140 degF)

Cat No Description

1756-N2 Slot filler module for empty slots in standard ControlLogix chassis

1756-N2XT Slot filler module for empty slots in ControlLogix-XT chassis

Publication 1756-SG001P-EN-P - May 2011 33

ControlLogix Power Supplies

ControlLogix power supplies are used with the 1756 chassis to provide 12V 33V 5V and 24V DC power directly to the chassis backplane Select from these configurations

Standard power Redundant power ControlLogix-XT power

For detailed specifications see 1756 ControlLogix Power Supplies Specifications publication 1756-TD005

Standard Power Supplies

You mount a standard power supply directly on the left end of the chassis where it plugs directly into the backplane

ControlLogix-XT Power Supplies

The ControlLogix-XT power supplies support extreme temperature environments

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA72 ControlLogix standard AC 120V220V AC 85hellip265V AC Standard series A and series B

1756-PA75 120V220V AC 85hellip265V AC Standard series B

1756-PB72 ControlLogix standard DC 24V DC 18hellip32V DC Standard series A and series B

1756-PB75 24V DC 1832V DC Standard series B

1756-PC75 48V DC 30hellip60V DC Standard series B

1756-PH75 125V DC 90hellip143V DC Standard series B

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PAXT ControlLogix-XT AC power supply 85265V AC 120240V AC XT

1756-PBXT ControlLogix-XT DC power supply 24V DC 18hellip32V DC XT

34 Publication 1756-SG001P-EN-P - May 2011

Redundant Power Supplies

To build a redundant power supply system you need the following

Two redundant power supplies (both 1756-PA75R or 1756-PB75R) One 1756-PSCA2 chassis adapter module Two 1756-CPR2 cables to connect the power supplies to the

1756-PSCA2 chassis adapter module (091 m (3 ft) length) User-supplied annunciator wiring to connect the power supplies to the

input modules as needed

The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Accessories - Redundant Power Supplies

Visualization Products Visualization products together with Logix for control and NetLinx architecture for communication make up the Rockwell Automation Integrated Architecture strategy The visualization strategy combines Rockwell Automation expertise in Allen-Bradley electronic operator interface and industrialized personal computer hardware with Rockwell Software supervisory control software Current visualization products include the following

FactoryTalk View software PanelView Plus operator interface PanelView Plus CE operator interface Industrial computers and monitors

For more information see the Operator Interface catalog pages at httpwwwabcomenepubcatalogs1276221813761239781

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA75R ControlLogix redundant 120V220V AC 85hellip265V AC Standard series B

1756-PB75R 24V DC 192hellip32V DC Standard series B

Cat No Description Specifications

1756-PSCA2 Chassis adapter module Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Mounts directly to left side of 1756 chassis

1756-CPR2 Chassis adapter cable Connects redundant power supply to 1756-PCSA2 chassis adapter Length091 m (3 ft)

Publication 1756-SG001P-EN-P - May 2011 35

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

HART Smart Instrumentation

HART (Highway Addressable Remote Transmitter) is an open protocol designed to connect analog devices For HART connectivity select from products available from Rockwell Automation and our Encompass partners

Typical HART Configuration

HART Interfaces

Accessories - IO Modules

1756 Removable Terminal Blocks

Removable terminal blocks (RTBs) provide a flexible interconnection between your plant wiring and 1756 IO modules The RTB plugs into the front of the IO module The type of module determines which RTB you need You can choose screw-clamp or spring-clamp RTBs

RTBs are not shipped with IO modules You must order them separately The standard housing on the front of the wiring arm is not deep enough for 25 mm2

HART Devices

ControlLogix Controller with 1756-IF8H or 1756-OF8H module

If your application has Select Description

Analog and HART connectivity in one moduleNo external hardware required to access HART signalHART commands can be transmitted as unscheduled messagesSupports asset management software to HART device

1756-IF8H1756-IF16H1756-OF8H

Rockwell Automation analog IO modules

Data acquisition or control application with slow update requirements (such as a tank farm)No external hardware required to access HART signalDoes not connect directly to asset management software

MVI56-HART Prosoft interface

Analog and HART in one moduleInstrumentation in hazardous locations (FLEX Ex modules)HART commands can be transmitted as unscheduled messagesDirectly connects asset management software to HART devices

1794 FLEX IO1797 FLEX Ex IO

There are specific FLEX IO and FLEX Ex modules designed for HART systems These catalog numbers end in an H such as 1797-IE8H

Publication 1756-SG001P-EN-P - May 2011 13

(14 AWG) wiring If you plan to use 25 mm2 (14 AWG) wiring also order the extended housing

Wiring Systems

As an alternative to buying RTBs and connecting the wires yourself you can buy a wiring system of the following

Interface modules (IFMs) that provide the output terminal blocks for digital IO modules Use the pre-wired cables that match the IO module to the IFM

Analog interface modules (AIFMs) that provide the output terminal blocks for analog IO modules Use the pre-wired cables that match the IO module to the AIFM

IO module-ready cables One end of the cable assembly is an RTB that plugs into the front of the IO module The other end has individually color-coded conductors that connect to a standard terminal block

Attribute 1756-TBNH 1756-TBSH 1756-TBCH 1756-TBS6H 1756-TBE

Description 20-position NEMA screw-clamp removable block

20-pin spring-clamp removable terminal block with standard housing

36-pin cage-clamp removable terminal block with standard housing

36-pin spring-clamp removable terminal block with standard housing

Extended depth terminal block housing

Screw torque 08hellip1 Nbullm7hellip9 lbbullin

04 Nbullm44 lbbullin

mdash

Screwdriver width 8 mm (516 in) max

IO Module

RTBPre-wired Cable

Factory-wired

Interface Module (IFM)

Field Wiring

14 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Integrated Motion

The Logix architecture supports motion control components that work in a wide variety of machine architectures

Integrated motion on EtherNetIP supports a connection to Ethernet drives

The Kinetix integrated-motion solution uses a SERCOS interface module to perform multi-axis synchronized motion

Logix integrated motion supports the analog family of servo modules for controlling drivesactuators

Networked motion provides the ability to connect via the DeviceNet network to a single axis drive to perform point-to-point indexing

For detailed specifications on motion interface modules see 1756 ControlLogix Integrated Motion Specifications publication 1756-TD004

For more information see these publications

Motion Analyzer CD to size your motion application and to make final component selection Download the software from httpwwwabcommotionsoftwareanalyzerhtml

Kinetix Motion Control Selection Guide publication GMC-SG001 to verify drive motor and accessory specifications

Integrated Motion on an EtherNetIP Network

Product Consideration

Drive that supports EtherNetIP connections Unlimited velocity torque and Vhz configured drives Kinetix 6500 drives PowerFlex 755 drives

ControlLogix controller As many as 100 drives per controller

ControlLogix EtherNetIP communication module 1hellip8 position configured drives with 1756-EN2TR module 1hellip255 position configured drives with 1756-EN3TR module

Publication 1756-SG001P-EN-P - May 2011 15

SERCOS Interface Modules

The SERCOS interface modules can connect to these servo drives

2093 Kinetix 2000 multi-axis servo drive 2094 Kinetix 6000 multi-axis servo drive 2099 Kinetix 7000 high-power servo drive 2098 Ultra3000 SERCOS servo drive

ControlLogix Controller

PanelView Plus Terminal

Workstations

POINT IO ModulesDrive with EtherNetIP Connection

Cat No Description Number of Axis

1756-M16SE Rockwell Automation SERCOS interface modules 16

1756-M08SE 8

1756-M03SE 3

1756-M08SEG SERCOS interface drives that are Extended Pack Profile compliant 8

16 Publication 1756-SG001P-EN-P - May 2011

Analog Motion Interface Modules

RSLogix 5000 Software1756-MxxSE Module

ControlLogix Controller

Three-phase Input Power

Line Interface Module

Integrated Axis Module

Motor Motor Feedback

Axis Modules

Slot Filler Module

Shunt Module

SERCOS Fiber-optic RingKinetix 6000 Multi-axis Servo Drive

Cat No Description Number of Axis

1756-M02AE Analog servo interface drives with quadrature feedback 2

1756-HYD02 Analog hydraulic servo interface drives LDT feedback 2

1756-M02AS Analog servo interface drives with SSI feedback 2

Publication 1756-SG001P-EN-P - May 2011 17

ControlLogix Communication Modules

Separate communication modules are available for different networks Install multiple communication modules into the ControlLogix backplane to bridge or route control and information data between different networks You can route a message through a maximum of four chassis (eight communication hops) You do not need a ControlLogix controller in the chassis

For detailed specifications see 1756 ControlLogix Network Specifications publication 1756-TD003

Application Network Page

Plant management (material handling) Configuration data collection and control on a single high-speed network Time-critical applications with no established schedule Inclusion of commercial technologies (such as video over IP) InternetIntranet connection Integrated CIP motion and safety

EtherNetIP network 19

High-speed transfer of time-critical data between controllers and IO devices Deterministic and repeatable data delivery Media redundancy Intrinsic safety Redundant controller systems

ControlNet network 20

Connections of low-level devices directly to plant floor controllers without interfacing them through IO modules

Data sent as needed More diagnostics for improved data collection and fault detection Less wiring and reduced start-up time than a traditional hard-wired system

DeviceNet network 21

Plant-wide and cell-level data sharing with program maintenance Data sent regularly Transfer of information between controllers

Data Highway Plus network 23

Connections between controllers and IO adapters Data sent regularly Distributed control so that each controller has its own IO and communicates with a

supervisory controller

Remote IO network 23

Fieldbus transmitters and actuators Closed-loop control Process automation

Foundation Fieldbus network 25

18 Publication 1756-SG001P-EN-P - May 2011

EtherNetIP Communication Modules

The Ethernet Industrial (EtherNetIP) network protocol is an open industrial-networking standard that supports both real-time IO messaging and message exchange The EtherNetIP network uses off-the-shelf Ethernet communication chips and physical media

Accessories - EtherNetIP Network

Cat No Description Media Communication Rate

CIP Motion Axes max

TCPIP Connections

Logix Connections

1756-EN2F EtherNetIP bridge fiber Fiber 100 Mbps 8 128 256

1756-EN2T EtherNetIP bridge copper Copper 10100 Mbps 8 128 256

1756-EN2TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 8 128 256

1756-EN3TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 255 128 256

1756-ENBT EtherNetIP bridge copper Copper 10100 Mbps mdash 64 128

1756-EWEB Ethernet web server module Copper 10100 Mbps mdash 64 128

1756-EN2TXT ControlLogix-XT extended temperature EtherNetIP bridge copper for extreme environments

Copper 10100 Mbps 8 128 256

Cat No Description Specifications

1585J-M8PBJM-x Ethernet RJ45 patchcordx = 2 (2 m) 5 (5 m) or 10 (10 m)

8-conductor Teal Riser PVC Cable (Flex Rated cable also available)

1585J-M8CC-H RJ45 insulation displacement connector (IDC) 01280325 mm2 (26hellip22 AWG) Cat 6 IDC no tool required

1585J-M8CC-C RJ45 crimp connector with boot qty = 50 pieces 01280205 mm2 (26hellip24 AWG Cat 5e requires crimp tool for assembly

1585A-Jcrimp Crimp tool mdash

9300-RADES Remote access dial-in kit 56 Kbps modem connection to devices on an Ethernet network includes pre-configured modem communication module DIN rail mounting hardware associated cables

Publication 1756-SG001P-EN-P - May 2011 19

Example Configuration - EtherNetIP Network

ControlNet Communication ModulesThe ControlNet network combines the functionality of an IO network and a peer-to-peer network providing high-speed performance The ControlNet network provides deterministic repeatable transfers of critical control data

FirewallRouter

Stratix Switch

Stratix Switch

Stratix Switch

Powermonitor 3000PowerFlex 70

Ethernet PLC-5

MicroLogix

Ethernet SLC 500

1756 IO

1794 IO

1761-NET-ENI

ControlNet

DeviceNet

1734 IO

RSLinxPanelView Plus

1769-L35E CompactLogix

Cat No Description Communication Rate

Logix Connections Number of Nodes

1756-CN2B ControlNet bridge standard media 5 Mbps 128(1) 99

1756-CN2RB ControlNet bridge redundant media 5 Mbps 128(1) 99

1756-CNB ControlNet bridge standard media 5 Mbps 64(2) 99

1756-CNBR ControlNet bridge redundant media 5 Mbps 64(2) 99

1756-CN2RXT ControlLogix-XT extended temperature ControlNet bridge redundant media

5 Mbps 128(1) 99

(1) 128 connections are available for standard use An additional three connections are reserved for redundant control

(2) Recommend using only 4048 Logix connections for IO

20 Publication 1756-SG001P-EN-P - May 2011

Example Configuration - ControlNet Network

Example Configuration - Redundant ControlNet Media

For information on ControlNet media see ControlNet Media System Components List AG-PA002

DeviceNet Communication Module

The DeviceNet network provides connections between simple industrial devices (such as sensors and actuators) and higher-level devices (such as controllers and computers)

1784-U2CNPanelView Plus

1788-CN2DN

DeviceNetPowerFlex 700SPLC-540CControlLogix

Redundant Media

ControlLogix1756-CNBR

ControlNet Node

ControlNet Node

Cat No Description Communication Rate Number of Nodes

1756-DNB DeviceNet bridge 125 Kbps (500 m max)250 Kbps (250 m max)500 Kbps (100 m max)

64

Publication 1756-SG001P-EN-P - May 2011 21

Example Configuration - DeviceNet Network

Accessories - DeviceNet Network

PLC-51771-SDN ControlLogix

1756-DNB

Ultra3000

PanelView Plus1784-U2DN

Ultra5000

IO

Motor starter

PowerFlex AC

Sensor Pushbuttons

LightsBar Code Scanner

Cat No Description

KwikLink Lite flat media KwikLink Lite flat media is a newer ODVA-approved solution for wiring DeviceNet networks Drop-lines for connecting nodes are added by using the KwikLink Lite two-piece connectors This cable system supports the intermixing of DeviceNet cable types (thin-round with flat) All of the KwikLink Lite connectors provide insulation displacement technology with reduced assembly time

KwikLink flat media The KwikLink flat media system provides a modular cabling method with its flat 4-wire cable and insulation displacement connectors (IDCs) The KwikLink system allows nodes to be added to the network without severing the trunkline Cutting or stripping of the trunkline is eliminated as is the need for predetermined cable lengths

Round media Round trunk cable is available in bulk spools or as pre-molded cordsets or patchcords in varying lengths A wide variety of rugged durable DeviceNet components is available for use in round trunk systems Stainless steel versions of round cable system components are also available Thick-trunk round media systems use thick cable for maximum DeviceNet trunk line length Round media thin-trunk systems use thin cable to reduce maximum trunk line distances with a more

compact and cost-effective installation for some applications Thin-cable outer jacket material is TPE for additional chemical resistance

22 Publication 1756-SG001P-EN-P - May 2011

Data Highway Plus and Remote IO Communication Modules

The Data Highway Plus network supports messaging between devices The remote IO link connects to remote IO chassis and other intelligent devices

The 1756-DHRIO module supports messaging between devices on DH+ networks The remote IO functionality enables the module to act as a scanner for transferring digital and block-transfer data to and from remote IO devices

The 1756-RIO module can act as a scanner or adapter on a remote IO network In addition to digital and block-transfer data the 1756-RIO module transfers analog and specialty data without message instructions

Cat No Description Communication Rate DH+ Connections RIO Connections Maximum Recommended Logix Connections

1756-DHRIO Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

1756-RIO Remote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

mdash Remote IO scanner or adapter32 physical racks (076) any combination of rack size and block transfers

10 scheduled IO

1756-DHRIOXT ControlLogix-XT extended temperature Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

Publication 1756-SG001P-EN-P - May 2011 23

Example Configuration - DH+ Network

Example Configuration - Remote IO Network

Accessories - DH+ and Remote IO Networks

PanelView Plus

PLC-5 1784-U2DHPRSLogix 5000

ControlLogix1756-DHRIO

SLC 504

PanelView PlusPLC-5

1791 IO1794 IO

1756-RIO as a Remote IO Adapter

1756-DHRIO as a Remote IO Scanner

Cat No Description Specifications

1770-CD Cable to connect communication module to DH+ network Belden 9463 twinaxial

9300-RADKIT Remote access dial-in kit 56 Kbps modem connection to devices on a DH+ network includes pre-configured modem communication module DIN rail mounting hardware associated cables

24 Publication 1756-SG001P-EN-P - May 2011

FOUNDATION Fieldbus Linking Devices

The FOUNDATION Fieldbus protocol is a network designed for distributed control of process applications

Example Configuration - Bridge to EtherNetIP Network

Cat No Description Communication Rate Number of H1 Ports

Devices per H1 Link

Devices per Linking Device

1757FFLD2 FOUNDATION Fieldbus bridge to an Ethernet network

FOUNDATION Fieldbus 3125 KbpsEtherNetIP 10100 Mbps

2 16(8hellip10 recommended)

32

1757-FFLD4 4 64

1757-FFLDC2 FOUNDATION Fieldbus bridge to a ControlNet network

FOUNDATION Fieldbus 3125 KbpsControlNet 5 Mbps

2 16(8hellip10 recommended)

32

1757-FFLDC4 4 64

FactoryTalk View SERSFieldbusRSLogix 5000

1757-FFLD4

H1(1)

H1(2)H1(3)H1(4)

HSEIP

Publication 1756-SG001P-EN-P - May 2011 25

Example Configuration - Bridge to ControlNet Network

Other Connectivity Options

ControlLogix RedundancyFactoryTalk View SERSFieldbusRSLogix 5000

ControlNet Redundant Media

1757-FFLDC2

FF H1

EtherNetIP

Option Consideration

USB connection The 1756-L7x controller has a USB port in place of the serial port If your application requires RS-232 functionality see the many Encompass partners at httpwwwrockwellautomationcomencompass

Serial connection The serial port on the 1756-L6x controller is compatible with RS-232 serial communication The serial port supports the DF1 protocol to communicate with other devices on the serial linkTo use Logix5000 controllers on Modbus you connect through the serial port and execute a specific ladder logic routine The controller project is available with RSLogix 5000 Enterprise programming software For more information see Using Logix5000 Controllers as Masters or Slaves on Modbus Application Solution publication CIG-AP129

DH-485 network The controller serial port is compatible with DH-485 communication The DH-485 connection does support remote programming and monitoring via RSLogix 5000 softwareOr add a DH-485 communication bridge module (cat no 1756-DH485)

SynchLink network The SynchLink communication module (1756-SYNCH) provides time synchronization and data broadcasting capabilities for distributed motion and coordinated drive control The module connects a ControlLogix chassis to a SynchLink fiber-optic communication link

26 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Controllers The ControlLogix controller provides a scalable controller solution that is capable of addressing a large amount of IO points

The controller can be placed into any slot of a ControlLogix chassis and multiple controllers can be installed in the same chassis Multiple controllers in the same chassis communicate with each other over the backplane (just as controllers can communicate over networks) but operate independently

ControlLogix controllers can monitor and control IO across the ControlLogix backplane as well as over IO links ControlLogix controllers can communicate over EtherNetIP ControlNet DeviceNet DH+ Remote IO and RS-232-C (DF1DH-485 protocol) networks and many third party process and device networks To provide communication for a ControlLogix controller install the appropriate communication interface module into the chassis

For detailed specifications see 1756 ControlLogix Controllers Specifications publication 1756-TD001

Cat No Description User Memory

1756-L72 ControlLogix controller 1 built-in USB port 4 MB

1756-L73 8 MB

1756-L74 16 MB

1756-L75 32 MB

1756-L61 ControlLogix controller 1 built-in RS-232 port 2 MB

1756-L62 4 MB

1756-L63 8 MB

1756-L64 16 MB

1756-L65 32 MB

1756-L61S GuardLogix safety controller 2 MB standard1 MB safety

1756-L62S 4 MB standard1 MB safety

1756-L63S 8 MB standard375 MB safety

1756-LSP GuardLogix safety partner (one is required for each GuardLogix controller) mdash

1756-L63XT ControlLogix-XT controller extreme environment 8 MB

IMPORTANT Scan time for a project loaded in a 1756-L64 or 1756-L65 controller may be slower than for the same project loaded in one of the other 1756-L6x controllers See the Logix5000 Controllers Instruction Execution Time and Memory Use Reference Manual publication 1756-RM087 for instruction execution times

Publication 1756-SG001P-EN-P - May 2011 27

Standard ControlLogix Controllers

The ControlLogix controller is part of the Logix5000 family of controllers A ControlLogix system includes the following

The ControlLogix controller available in different combinations of user memory

RSLogix 5000 programming software 1756 ControlLogix IO modules that reside in a 1756 chassis Separate communication modules for network communication

Features - Standard ControlLogix Controllers

Feature 1756-L61 1756-L62 1756-L63 1756-L64 1756-L65

1756-L72 1756-L73 1756-L74 1756-L75

Controller tasks 32 tasks 100 programstask Event tasks all event triggers

Built-in communication ports 1 port RS-232 serial 1 port USB

Communication options EtherNetIP ControlNet DeviceNet Data Highway Plus Remote IO SynchLink Third-party process and device networks

Built-in port Serial USB

Controller connections supported max 250 500

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Full support

Integrated motion EtherNetIP connection SERCOS interface Analog options (encoder input LDT input SSI input)

Programming languages Relay ladder Structured text Function block SFC

28 Publication 1756-SG001P-EN-P - May 2011

GuardLogix Controllers

A GuardLogix controller is a ControlLogix controller that also provides safety control The GuardLogix system is a dual controller solutionmdashyou must use a 1756-L6xS primary controller and a 1756-LSP safety partner to achieve SIL 3CAT 4

During development safety and standard have the same rules multiple programmers online editing and forcing are all allowed Once the project is tested and ready for final validation you set the Safety Task to a SIL 3 integrity level which is then enforced by the GuardLogix controller When safety memory is locked and protected the safety logic cant be modified and all safety functions operate with SIL 3 integrity On the standard side of the GuardLogix controller all functions operate like a regular Logix controller

Use Guard IO modules for field device connectivity on Ethernet or DeviceNet networks and for safety interlocking between GuardLogix controllers use Ethernet or ControlNet networks Multiple GuardLogix controllers can share safety data for zone to zone interlocking or a single GuardLogix controller can use remote distributed safety IO between different cellsareas

In addition to the standard features of a ControlLogix controller the GuardLogix controller has these safety-related features

Application Description

SIL 1 2 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508 and applications up to and including PLeCat4 according to ISO 13849-1 For more information see GuardLogix Controllers Systems Safety Reference Manual publication 1756-RM093 GuardLogix Controllers User Manual publication 1756-UM020 GuardLogix Safety Application Instruction Set Reference Manual publication 1756-RM095

Features - GuardLogix Controllers

Feature 1756-L61S 1756-L62S 1756-L63S 1756-LSP

Safety communication options Standard and safety EtherNetIP ControlNet DeviceNet

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Not supported

Programming languages Relay ladder

Publication 1756-SG001P-EN-P - May 2011 29

ControlLogix-XT Controllers

The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh corrosive environments

When used with FLEX IO-XT products the ControlLogix-XT system can withstand temperatures range from -2070 C (-4158 F)

When used independently the ControlLogix-XT system can withstand temperature ranges from -2570 C (-13158 F)

Redundant ControlLogix Controllers

The ControlLogix controller supports controller redundancy In a redundant controller system you need these components

Two 1756 chassis each with the following the same ndash Number of slots

ndash Modules in the same slots

ndash Redundancy firmware revisions in each module

ndash Two additional ControlNet nodes outside the redundant chassis pair

You need one of these redundancy modules

One 1756-RM module per chassis that supports the followingndash Two 1756-L61 1756-L62 1761-L63 controllers or one 1756-L64

controller

ndash Maximum of seven communication modules which can be 1756-CN2 series B 1756-CN2R series B and 1756-EN2T modules

ndash One 1756-RMCx cable

One 1757-SRM module per chassis that supports the followingndash One 1756-L61 1756-L62 1756-L63 1756-L64 controller

ndash Maximum of seven communication modules which can be 1756-CNB series D or E 1756-CNBR series D or E 1756-ENBT and 1756-EWEB modules

ndash One 1757-SRCx cable

30 Publication 1756-SG001P-EN-P - May 2011

Accessories - Controllers

Memory Cards

Memory cards offer nonvolatile memory to permanently store a user program and tag data on a controller The 1756-L7x ControlLogix controller comes with 1784-SD1 Secure Digital (SD) card already installed The 1756-L6x controllers support optional CompactFlash cards that you purchase separately The memory card installs in a socket on the controller Through RSLogix 5000 software you can manually trigger the controller to save to or load from nonvolatile memory or configure the controller to load from nonvolatile memory on powerup

The GuardLogix controller does not support user program storage or retrieval by using a CompactFlash card

1756 Energy Storage Modules

Instead of a battery the 1756-L7x controller ships with a 1756-ESMCAP energy storage module (ESM) already installed

Attribute 1784-CF64 1784-CF128 1784-SD1 1784-SD2

Memory 64 MB 128 MB 1 GB 2 GB

Supported controllers 1756-L6x 1756-L7x

Weight approx 142 g (05 oz) 176 g (0062 oz)

Cat No Description

1756-ESMCAP Capacitor-based energy-storage module Comes with the controller

1756-EMNSE ESM without WallClockTime backup power Additionally you can use this ESM with a 1756-L73 (8 MB) or smaller memory-sized controller only

Use this ESM if your application requires that the installed ESM deplete its residual energy to 40 microJoule or less before transporting it into or out of your application

1756-ESMNRM Energy-storage module that secures the controller by preventing the USB connection and SD card useThis ESM provides your application an enhanced degree of security

Publication 1756-SG001P-EN-P - May 2011 31

1756 ControlLogix Batteries

Each 1756-L6x controller ships with a battery With a memory card installed the controller can be used without a battery If you do not use a battery current tag data will be at the state it was when the memory card was saved

ControlLogix Chassis The ControlLogix system is a modular system that requires a 1756 IO chassis Place any module into any slot The backplane provides a high-speed communication path between modules

All of the chassis are designed for horizontal-only back-panel mounting The chassis are available in these configurations

Standard chassis ControlLogix-XT chassis

For detailed specifications see 1756 ControlLogix Chassis Specifications Specifications publication 1756-TD006

Features - Chassis

Slot guides and snap-in retention for easy and secure module fit for any type of 1756 module

Direct mounting accommodates any 1756 power supply

Attribute 1756-BA1 1756-BA2 1756-BATM(1) 1756-BATA

Description Lithium battery (059 g) Lithium battery (059 g) Externally mounted battery assembly

Replacement lithium battery for 1756-BATM (5 g max lithium per each D cell contains 2 D cells)

ControlLogix controllers 1756-L61 1756-L62 1756-L63 series A

1756-L61 1756-L62 1756-L63 series B1756-L64 1756-L65

1756-L61 1756-L62 1756-L63 series A

1756-BATM battery module

GuardLogix controllers mdash 1756-L61S 1756-L62S 1756-L63S

mdash mdash

ControlLogix-XT controllers

mdash 1756-L63XT mdash mdash

(1) The 1756-BATM externally mounted battery assembly is highly recommended for use with all series A 1756-L6x controllers and provides longer battery life than the 1756-BA1 battery The 1756-BATM includes one 1756-BATA lithium battery assembly and a 1 m (328 ft) cable to connect housing to controller

32 Publication 1756-SG001P-EN-P - May 2011

Standard Chassis

The chassis backplane provides a high-speed communication path between modules and distributes power to each of the modules within the chassis

ControlLogix-XT Chassis

The ControlLogix-XT chassis support extreme temperature environments

Accessories - Chassis

Use a slot filler module to fill empty slots

Cat No Description Slots

1756-A4 ControlLogix standard chassis 4

1756-A7 7

1756-A10 10

1756-A13 13

1756-A17 17

Cat No Description Slots Temperature Range

1756-A4LXT ControlLogix-XT chassis 4 -2560 degC (-13140 degF)

1756-A5XT 5 -2570 degC (-13158 degF)

1756-A7LXT 7 -2560 degC (-13140 degF)

Cat No Description

1756-N2 Slot filler module for empty slots in standard ControlLogix chassis

1756-N2XT Slot filler module for empty slots in ControlLogix-XT chassis

Publication 1756-SG001P-EN-P - May 2011 33

ControlLogix Power Supplies

ControlLogix power supplies are used with the 1756 chassis to provide 12V 33V 5V and 24V DC power directly to the chassis backplane Select from these configurations

Standard power Redundant power ControlLogix-XT power

For detailed specifications see 1756 ControlLogix Power Supplies Specifications publication 1756-TD005

Standard Power Supplies

You mount a standard power supply directly on the left end of the chassis where it plugs directly into the backplane

ControlLogix-XT Power Supplies

The ControlLogix-XT power supplies support extreme temperature environments

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA72 ControlLogix standard AC 120V220V AC 85hellip265V AC Standard series A and series B

1756-PA75 120V220V AC 85hellip265V AC Standard series B

1756-PB72 ControlLogix standard DC 24V DC 18hellip32V DC Standard series A and series B

1756-PB75 24V DC 1832V DC Standard series B

1756-PC75 48V DC 30hellip60V DC Standard series B

1756-PH75 125V DC 90hellip143V DC Standard series B

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PAXT ControlLogix-XT AC power supply 85265V AC 120240V AC XT

1756-PBXT ControlLogix-XT DC power supply 24V DC 18hellip32V DC XT

34 Publication 1756-SG001P-EN-P - May 2011

Redundant Power Supplies

To build a redundant power supply system you need the following

Two redundant power supplies (both 1756-PA75R or 1756-PB75R) One 1756-PSCA2 chassis adapter module Two 1756-CPR2 cables to connect the power supplies to the

1756-PSCA2 chassis adapter module (091 m (3 ft) length) User-supplied annunciator wiring to connect the power supplies to the

input modules as needed

The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Accessories - Redundant Power Supplies

Visualization Products Visualization products together with Logix for control and NetLinx architecture for communication make up the Rockwell Automation Integrated Architecture strategy The visualization strategy combines Rockwell Automation expertise in Allen-Bradley electronic operator interface and industrialized personal computer hardware with Rockwell Software supervisory control software Current visualization products include the following

FactoryTalk View software PanelView Plus operator interface PanelView Plus CE operator interface Industrial computers and monitors

For more information see the Operator Interface catalog pages at httpwwwabcomenepubcatalogs1276221813761239781

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA75R ControlLogix redundant 120V220V AC 85hellip265V AC Standard series B

1756-PB75R 24V DC 192hellip32V DC Standard series B

Cat No Description Specifications

1756-PSCA2 Chassis adapter module Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Mounts directly to left side of 1756 chassis

1756-CPR2 Chassis adapter cable Connects redundant power supply to 1756-PCSA2 chassis adapter Length091 m (3 ft)

Publication 1756-SG001P-EN-P - May 2011 35

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP ltFEFF005500740069006c0069006300650020006500730074006100200063006f006e0066006900670075007200610063006900f3006e0020007000610072006100200063007200650061007200200064006f00630075006d0065006e0074006f0073002000640065002000410064006f0062006500200050004400460020007000610072006100200063006f006e00730065006700750069007200200069006d0070007200650073006900f3006e002000640065002000630061006c006900640061006400200065006e00200069006d0070007200650073006f0072006100730020006400650020006500730063007200690074006f00720069006f00200079002000680065007200720061006d00690065006e00740061007300200064006500200063006f00720072006500630063006900f3006e002e002000530065002000700075006500640065006e00200061006200720069007200200064006f00630075006d0065006e0074006f00730020005000440046002000630072006500610064006f007300200063006f006e0020004100630072006f006200610074002c002000410064006f00620065002000520065006100640065007200200035002e003000200079002000760065007200730069006f006e0065007300200070006f00730074006500720069006f007200650073002egt FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO ltFEFF004b00e40079007400e40020006e00e40069007400e4002000610073006500740075006b007300690061002c0020006b0075006e0020006c0075006f0074002000410064006f0062006500200050004400460020002d0064006f006b0075006d0065006e007400740065006a00610020006c0061006100640075006b006100730074006100200074007900f6007000f60079007400e400740075006c006f0073007400750073007400610020006a00610020007600650064006f007300740075007300740061002000760061007200740065006e002e00200020004c0075006f0064007500740020005000440046002d0064006f006b0075006d0065006e00740069007400200076006f0069006400610061006e0020006100760061007400610020004100630072006f0062006100740069006c006c00610020006a0061002000410064006f00620065002000520065006100640065007200200035002e0030003a006c006c00610020006a006100200075007500640065006d006d0069006c006c0061002egt SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

(14 AWG) wiring If you plan to use 25 mm2 (14 AWG) wiring also order the extended housing

Wiring Systems

As an alternative to buying RTBs and connecting the wires yourself you can buy a wiring system of the following

Interface modules (IFMs) that provide the output terminal blocks for digital IO modules Use the pre-wired cables that match the IO module to the IFM

Analog interface modules (AIFMs) that provide the output terminal blocks for analog IO modules Use the pre-wired cables that match the IO module to the AIFM

IO module-ready cables One end of the cable assembly is an RTB that plugs into the front of the IO module The other end has individually color-coded conductors that connect to a standard terminal block

Attribute 1756-TBNH 1756-TBSH 1756-TBCH 1756-TBS6H 1756-TBE

Description 20-position NEMA screw-clamp removable block

20-pin spring-clamp removable terminal block with standard housing

36-pin cage-clamp removable terminal block with standard housing

36-pin spring-clamp removable terminal block with standard housing

Extended depth terminal block housing

Screw torque 08hellip1 Nbullm7hellip9 lbbullin

04 Nbullm44 lbbullin

mdash

Screwdriver width 8 mm (516 in) max

IO Module

RTBPre-wired Cable

Factory-wired

Interface Module (IFM)

Field Wiring

14 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Integrated Motion

The Logix architecture supports motion control components that work in a wide variety of machine architectures

Integrated motion on EtherNetIP supports a connection to Ethernet drives

The Kinetix integrated-motion solution uses a SERCOS interface module to perform multi-axis synchronized motion

Logix integrated motion supports the analog family of servo modules for controlling drivesactuators

Networked motion provides the ability to connect via the DeviceNet network to a single axis drive to perform point-to-point indexing

For detailed specifications on motion interface modules see 1756 ControlLogix Integrated Motion Specifications publication 1756-TD004

For more information see these publications

Motion Analyzer CD to size your motion application and to make final component selection Download the software from httpwwwabcommotionsoftwareanalyzerhtml

Kinetix Motion Control Selection Guide publication GMC-SG001 to verify drive motor and accessory specifications

Integrated Motion on an EtherNetIP Network

Product Consideration

Drive that supports EtherNetIP connections Unlimited velocity torque and Vhz configured drives Kinetix 6500 drives PowerFlex 755 drives

ControlLogix controller As many as 100 drives per controller

ControlLogix EtherNetIP communication module 1hellip8 position configured drives with 1756-EN2TR module 1hellip255 position configured drives with 1756-EN3TR module

Publication 1756-SG001P-EN-P - May 2011 15

SERCOS Interface Modules

The SERCOS interface modules can connect to these servo drives

2093 Kinetix 2000 multi-axis servo drive 2094 Kinetix 6000 multi-axis servo drive 2099 Kinetix 7000 high-power servo drive 2098 Ultra3000 SERCOS servo drive

ControlLogix Controller

PanelView Plus Terminal

Workstations

POINT IO ModulesDrive with EtherNetIP Connection

Cat No Description Number of Axis

1756-M16SE Rockwell Automation SERCOS interface modules 16

1756-M08SE 8

1756-M03SE 3

1756-M08SEG SERCOS interface drives that are Extended Pack Profile compliant 8

16 Publication 1756-SG001P-EN-P - May 2011

Analog Motion Interface Modules

RSLogix 5000 Software1756-MxxSE Module

ControlLogix Controller

Three-phase Input Power

Line Interface Module

Integrated Axis Module

Motor Motor Feedback

Axis Modules

Slot Filler Module

Shunt Module

SERCOS Fiber-optic RingKinetix 6000 Multi-axis Servo Drive

Cat No Description Number of Axis

1756-M02AE Analog servo interface drives with quadrature feedback 2

1756-HYD02 Analog hydraulic servo interface drives LDT feedback 2

1756-M02AS Analog servo interface drives with SSI feedback 2

Publication 1756-SG001P-EN-P - May 2011 17

ControlLogix Communication Modules

Separate communication modules are available for different networks Install multiple communication modules into the ControlLogix backplane to bridge or route control and information data between different networks You can route a message through a maximum of four chassis (eight communication hops) You do not need a ControlLogix controller in the chassis

For detailed specifications see 1756 ControlLogix Network Specifications publication 1756-TD003

Application Network Page

Plant management (material handling) Configuration data collection and control on a single high-speed network Time-critical applications with no established schedule Inclusion of commercial technologies (such as video over IP) InternetIntranet connection Integrated CIP motion and safety

EtherNetIP network 19

High-speed transfer of time-critical data between controllers and IO devices Deterministic and repeatable data delivery Media redundancy Intrinsic safety Redundant controller systems

ControlNet network 20

Connections of low-level devices directly to plant floor controllers without interfacing them through IO modules

Data sent as needed More diagnostics for improved data collection and fault detection Less wiring and reduced start-up time than a traditional hard-wired system

DeviceNet network 21

Plant-wide and cell-level data sharing with program maintenance Data sent regularly Transfer of information between controllers

Data Highway Plus network 23

Connections between controllers and IO adapters Data sent regularly Distributed control so that each controller has its own IO and communicates with a

supervisory controller

Remote IO network 23

Fieldbus transmitters and actuators Closed-loop control Process automation

Foundation Fieldbus network 25

18 Publication 1756-SG001P-EN-P - May 2011

EtherNetIP Communication Modules

The Ethernet Industrial (EtherNetIP) network protocol is an open industrial-networking standard that supports both real-time IO messaging and message exchange The EtherNetIP network uses off-the-shelf Ethernet communication chips and physical media

Accessories - EtherNetIP Network

Cat No Description Media Communication Rate

CIP Motion Axes max

TCPIP Connections

Logix Connections

1756-EN2F EtherNetIP bridge fiber Fiber 100 Mbps 8 128 256

1756-EN2T EtherNetIP bridge copper Copper 10100 Mbps 8 128 256

1756-EN2TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 8 128 256

1756-EN3TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 255 128 256

1756-ENBT EtherNetIP bridge copper Copper 10100 Mbps mdash 64 128

1756-EWEB Ethernet web server module Copper 10100 Mbps mdash 64 128

1756-EN2TXT ControlLogix-XT extended temperature EtherNetIP bridge copper for extreme environments

Copper 10100 Mbps 8 128 256

Cat No Description Specifications

1585J-M8PBJM-x Ethernet RJ45 patchcordx = 2 (2 m) 5 (5 m) or 10 (10 m)

8-conductor Teal Riser PVC Cable (Flex Rated cable also available)

1585J-M8CC-H RJ45 insulation displacement connector (IDC) 01280325 mm2 (26hellip22 AWG) Cat 6 IDC no tool required

1585J-M8CC-C RJ45 crimp connector with boot qty = 50 pieces 01280205 mm2 (26hellip24 AWG Cat 5e requires crimp tool for assembly

1585A-Jcrimp Crimp tool mdash

9300-RADES Remote access dial-in kit 56 Kbps modem connection to devices on an Ethernet network includes pre-configured modem communication module DIN rail mounting hardware associated cables

Publication 1756-SG001P-EN-P - May 2011 19

Example Configuration - EtherNetIP Network

ControlNet Communication ModulesThe ControlNet network combines the functionality of an IO network and a peer-to-peer network providing high-speed performance The ControlNet network provides deterministic repeatable transfers of critical control data

FirewallRouter

Stratix Switch

Stratix Switch

Stratix Switch

Powermonitor 3000PowerFlex 70

Ethernet PLC-5

MicroLogix

Ethernet SLC 500

1756 IO

1794 IO

1761-NET-ENI

ControlNet

DeviceNet

1734 IO

RSLinxPanelView Plus

1769-L35E CompactLogix

Cat No Description Communication Rate

Logix Connections Number of Nodes

1756-CN2B ControlNet bridge standard media 5 Mbps 128(1) 99

1756-CN2RB ControlNet bridge redundant media 5 Mbps 128(1) 99

1756-CNB ControlNet bridge standard media 5 Mbps 64(2) 99

1756-CNBR ControlNet bridge redundant media 5 Mbps 64(2) 99

1756-CN2RXT ControlLogix-XT extended temperature ControlNet bridge redundant media

5 Mbps 128(1) 99

(1) 128 connections are available for standard use An additional three connections are reserved for redundant control

(2) Recommend using only 4048 Logix connections for IO

20 Publication 1756-SG001P-EN-P - May 2011

Example Configuration - ControlNet Network

Example Configuration - Redundant ControlNet Media

For information on ControlNet media see ControlNet Media System Components List AG-PA002

DeviceNet Communication Module

The DeviceNet network provides connections between simple industrial devices (such as sensors and actuators) and higher-level devices (such as controllers and computers)

1784-U2CNPanelView Plus

1788-CN2DN

DeviceNetPowerFlex 700SPLC-540CControlLogix

Redundant Media

ControlLogix1756-CNBR

ControlNet Node

ControlNet Node

Cat No Description Communication Rate Number of Nodes

1756-DNB DeviceNet bridge 125 Kbps (500 m max)250 Kbps (250 m max)500 Kbps (100 m max)

64

Publication 1756-SG001P-EN-P - May 2011 21

Example Configuration - DeviceNet Network

Accessories - DeviceNet Network

PLC-51771-SDN ControlLogix

1756-DNB

Ultra3000

PanelView Plus1784-U2DN

Ultra5000

IO

Motor starter

PowerFlex AC

Sensor Pushbuttons

LightsBar Code Scanner

Cat No Description

KwikLink Lite flat media KwikLink Lite flat media is a newer ODVA-approved solution for wiring DeviceNet networks Drop-lines for connecting nodes are added by using the KwikLink Lite two-piece connectors This cable system supports the intermixing of DeviceNet cable types (thin-round with flat) All of the KwikLink Lite connectors provide insulation displacement technology with reduced assembly time

KwikLink flat media The KwikLink flat media system provides a modular cabling method with its flat 4-wire cable and insulation displacement connectors (IDCs) The KwikLink system allows nodes to be added to the network without severing the trunkline Cutting or stripping of the trunkline is eliminated as is the need for predetermined cable lengths

Round media Round trunk cable is available in bulk spools or as pre-molded cordsets or patchcords in varying lengths A wide variety of rugged durable DeviceNet components is available for use in round trunk systems Stainless steel versions of round cable system components are also available Thick-trunk round media systems use thick cable for maximum DeviceNet trunk line length Round media thin-trunk systems use thin cable to reduce maximum trunk line distances with a more

compact and cost-effective installation for some applications Thin-cable outer jacket material is TPE for additional chemical resistance

22 Publication 1756-SG001P-EN-P - May 2011

Data Highway Plus and Remote IO Communication Modules

The Data Highway Plus network supports messaging between devices The remote IO link connects to remote IO chassis and other intelligent devices

The 1756-DHRIO module supports messaging between devices on DH+ networks The remote IO functionality enables the module to act as a scanner for transferring digital and block-transfer data to and from remote IO devices

The 1756-RIO module can act as a scanner or adapter on a remote IO network In addition to digital and block-transfer data the 1756-RIO module transfers analog and specialty data without message instructions

Cat No Description Communication Rate DH+ Connections RIO Connections Maximum Recommended Logix Connections

1756-DHRIO Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

1756-RIO Remote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

mdash Remote IO scanner or adapter32 physical racks (076) any combination of rack size and block transfers

10 scheduled IO

1756-DHRIOXT ControlLogix-XT extended temperature Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

Publication 1756-SG001P-EN-P - May 2011 23

Example Configuration - DH+ Network

Example Configuration - Remote IO Network

Accessories - DH+ and Remote IO Networks

PanelView Plus

PLC-5 1784-U2DHPRSLogix 5000

ControlLogix1756-DHRIO

SLC 504

PanelView PlusPLC-5

1791 IO1794 IO

1756-RIO as a Remote IO Adapter

1756-DHRIO as a Remote IO Scanner

Cat No Description Specifications

1770-CD Cable to connect communication module to DH+ network Belden 9463 twinaxial

9300-RADKIT Remote access dial-in kit 56 Kbps modem connection to devices on a DH+ network includes pre-configured modem communication module DIN rail mounting hardware associated cables

24 Publication 1756-SG001P-EN-P - May 2011

FOUNDATION Fieldbus Linking Devices

The FOUNDATION Fieldbus protocol is a network designed for distributed control of process applications

Example Configuration - Bridge to EtherNetIP Network

Cat No Description Communication Rate Number of H1 Ports

Devices per H1 Link

Devices per Linking Device

1757FFLD2 FOUNDATION Fieldbus bridge to an Ethernet network

FOUNDATION Fieldbus 3125 KbpsEtherNetIP 10100 Mbps

2 16(8hellip10 recommended)

32

1757-FFLD4 4 64

1757-FFLDC2 FOUNDATION Fieldbus bridge to a ControlNet network

FOUNDATION Fieldbus 3125 KbpsControlNet 5 Mbps

2 16(8hellip10 recommended)

32

1757-FFLDC4 4 64

FactoryTalk View SERSFieldbusRSLogix 5000

1757-FFLD4

H1(1)

H1(2)H1(3)H1(4)

HSEIP

Publication 1756-SG001P-EN-P - May 2011 25

Example Configuration - Bridge to ControlNet Network

Other Connectivity Options

ControlLogix RedundancyFactoryTalk View SERSFieldbusRSLogix 5000

ControlNet Redundant Media

1757-FFLDC2

FF H1

EtherNetIP

Option Consideration

USB connection The 1756-L7x controller has a USB port in place of the serial port If your application requires RS-232 functionality see the many Encompass partners at httpwwwrockwellautomationcomencompass

Serial connection The serial port on the 1756-L6x controller is compatible with RS-232 serial communication The serial port supports the DF1 protocol to communicate with other devices on the serial linkTo use Logix5000 controllers on Modbus you connect through the serial port and execute a specific ladder logic routine The controller project is available with RSLogix 5000 Enterprise programming software For more information see Using Logix5000 Controllers as Masters or Slaves on Modbus Application Solution publication CIG-AP129

DH-485 network The controller serial port is compatible with DH-485 communication The DH-485 connection does support remote programming and monitoring via RSLogix 5000 softwareOr add a DH-485 communication bridge module (cat no 1756-DH485)

SynchLink network The SynchLink communication module (1756-SYNCH) provides time synchronization and data broadcasting capabilities for distributed motion and coordinated drive control The module connects a ControlLogix chassis to a SynchLink fiber-optic communication link

26 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Controllers The ControlLogix controller provides a scalable controller solution that is capable of addressing a large amount of IO points

The controller can be placed into any slot of a ControlLogix chassis and multiple controllers can be installed in the same chassis Multiple controllers in the same chassis communicate with each other over the backplane (just as controllers can communicate over networks) but operate independently

ControlLogix controllers can monitor and control IO across the ControlLogix backplane as well as over IO links ControlLogix controllers can communicate over EtherNetIP ControlNet DeviceNet DH+ Remote IO and RS-232-C (DF1DH-485 protocol) networks and many third party process and device networks To provide communication for a ControlLogix controller install the appropriate communication interface module into the chassis

For detailed specifications see 1756 ControlLogix Controllers Specifications publication 1756-TD001

Cat No Description User Memory

1756-L72 ControlLogix controller 1 built-in USB port 4 MB

1756-L73 8 MB

1756-L74 16 MB

1756-L75 32 MB

1756-L61 ControlLogix controller 1 built-in RS-232 port 2 MB

1756-L62 4 MB

1756-L63 8 MB

1756-L64 16 MB

1756-L65 32 MB

1756-L61S GuardLogix safety controller 2 MB standard1 MB safety

1756-L62S 4 MB standard1 MB safety

1756-L63S 8 MB standard375 MB safety

1756-LSP GuardLogix safety partner (one is required for each GuardLogix controller) mdash

1756-L63XT ControlLogix-XT controller extreme environment 8 MB

IMPORTANT Scan time for a project loaded in a 1756-L64 or 1756-L65 controller may be slower than for the same project loaded in one of the other 1756-L6x controllers See the Logix5000 Controllers Instruction Execution Time and Memory Use Reference Manual publication 1756-RM087 for instruction execution times

Publication 1756-SG001P-EN-P - May 2011 27

Standard ControlLogix Controllers

The ControlLogix controller is part of the Logix5000 family of controllers A ControlLogix system includes the following

The ControlLogix controller available in different combinations of user memory

RSLogix 5000 programming software 1756 ControlLogix IO modules that reside in a 1756 chassis Separate communication modules for network communication

Features - Standard ControlLogix Controllers

Feature 1756-L61 1756-L62 1756-L63 1756-L64 1756-L65

1756-L72 1756-L73 1756-L74 1756-L75

Controller tasks 32 tasks 100 programstask Event tasks all event triggers

Built-in communication ports 1 port RS-232 serial 1 port USB

Communication options EtherNetIP ControlNet DeviceNet Data Highway Plus Remote IO SynchLink Third-party process and device networks

Built-in port Serial USB

Controller connections supported max 250 500

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Full support

Integrated motion EtherNetIP connection SERCOS interface Analog options (encoder input LDT input SSI input)

Programming languages Relay ladder Structured text Function block SFC

28 Publication 1756-SG001P-EN-P - May 2011

GuardLogix Controllers

A GuardLogix controller is a ControlLogix controller that also provides safety control The GuardLogix system is a dual controller solutionmdashyou must use a 1756-L6xS primary controller and a 1756-LSP safety partner to achieve SIL 3CAT 4

During development safety and standard have the same rules multiple programmers online editing and forcing are all allowed Once the project is tested and ready for final validation you set the Safety Task to a SIL 3 integrity level which is then enforced by the GuardLogix controller When safety memory is locked and protected the safety logic cant be modified and all safety functions operate with SIL 3 integrity On the standard side of the GuardLogix controller all functions operate like a regular Logix controller

Use Guard IO modules for field device connectivity on Ethernet or DeviceNet networks and for safety interlocking between GuardLogix controllers use Ethernet or ControlNet networks Multiple GuardLogix controllers can share safety data for zone to zone interlocking or a single GuardLogix controller can use remote distributed safety IO between different cellsareas

In addition to the standard features of a ControlLogix controller the GuardLogix controller has these safety-related features

Application Description

SIL 1 2 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508 and applications up to and including PLeCat4 according to ISO 13849-1 For more information see GuardLogix Controllers Systems Safety Reference Manual publication 1756-RM093 GuardLogix Controllers User Manual publication 1756-UM020 GuardLogix Safety Application Instruction Set Reference Manual publication 1756-RM095

Features - GuardLogix Controllers

Feature 1756-L61S 1756-L62S 1756-L63S 1756-LSP

Safety communication options Standard and safety EtherNetIP ControlNet DeviceNet

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Not supported

Programming languages Relay ladder

Publication 1756-SG001P-EN-P - May 2011 29

ControlLogix-XT Controllers

The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh corrosive environments

When used with FLEX IO-XT products the ControlLogix-XT system can withstand temperatures range from -2070 C (-4158 F)

When used independently the ControlLogix-XT system can withstand temperature ranges from -2570 C (-13158 F)

Redundant ControlLogix Controllers

The ControlLogix controller supports controller redundancy In a redundant controller system you need these components

Two 1756 chassis each with the following the same ndash Number of slots

ndash Modules in the same slots

ndash Redundancy firmware revisions in each module

ndash Two additional ControlNet nodes outside the redundant chassis pair

You need one of these redundancy modules

One 1756-RM module per chassis that supports the followingndash Two 1756-L61 1756-L62 1761-L63 controllers or one 1756-L64

controller

ndash Maximum of seven communication modules which can be 1756-CN2 series B 1756-CN2R series B and 1756-EN2T modules

ndash One 1756-RMCx cable

One 1757-SRM module per chassis that supports the followingndash One 1756-L61 1756-L62 1756-L63 1756-L64 controller

ndash Maximum of seven communication modules which can be 1756-CNB series D or E 1756-CNBR series D or E 1756-ENBT and 1756-EWEB modules

ndash One 1757-SRCx cable

30 Publication 1756-SG001P-EN-P - May 2011

Accessories - Controllers

Memory Cards

Memory cards offer nonvolatile memory to permanently store a user program and tag data on a controller The 1756-L7x ControlLogix controller comes with 1784-SD1 Secure Digital (SD) card already installed The 1756-L6x controllers support optional CompactFlash cards that you purchase separately The memory card installs in a socket on the controller Through RSLogix 5000 software you can manually trigger the controller to save to or load from nonvolatile memory or configure the controller to load from nonvolatile memory on powerup

The GuardLogix controller does not support user program storage or retrieval by using a CompactFlash card

1756 Energy Storage Modules

Instead of a battery the 1756-L7x controller ships with a 1756-ESMCAP energy storage module (ESM) already installed

Attribute 1784-CF64 1784-CF128 1784-SD1 1784-SD2

Memory 64 MB 128 MB 1 GB 2 GB

Supported controllers 1756-L6x 1756-L7x

Weight approx 142 g (05 oz) 176 g (0062 oz)

Cat No Description

1756-ESMCAP Capacitor-based energy-storage module Comes with the controller

1756-EMNSE ESM without WallClockTime backup power Additionally you can use this ESM with a 1756-L73 (8 MB) or smaller memory-sized controller only

Use this ESM if your application requires that the installed ESM deplete its residual energy to 40 microJoule or less before transporting it into or out of your application

1756-ESMNRM Energy-storage module that secures the controller by preventing the USB connection and SD card useThis ESM provides your application an enhanced degree of security

Publication 1756-SG001P-EN-P - May 2011 31

1756 ControlLogix Batteries

Each 1756-L6x controller ships with a battery With a memory card installed the controller can be used without a battery If you do not use a battery current tag data will be at the state it was when the memory card was saved

ControlLogix Chassis The ControlLogix system is a modular system that requires a 1756 IO chassis Place any module into any slot The backplane provides a high-speed communication path between modules

All of the chassis are designed for horizontal-only back-panel mounting The chassis are available in these configurations

Standard chassis ControlLogix-XT chassis

For detailed specifications see 1756 ControlLogix Chassis Specifications Specifications publication 1756-TD006

Features - Chassis

Slot guides and snap-in retention for easy and secure module fit for any type of 1756 module

Direct mounting accommodates any 1756 power supply

Attribute 1756-BA1 1756-BA2 1756-BATM(1) 1756-BATA

Description Lithium battery (059 g) Lithium battery (059 g) Externally mounted battery assembly

Replacement lithium battery for 1756-BATM (5 g max lithium per each D cell contains 2 D cells)

ControlLogix controllers 1756-L61 1756-L62 1756-L63 series A

1756-L61 1756-L62 1756-L63 series B1756-L64 1756-L65

1756-L61 1756-L62 1756-L63 series A

1756-BATM battery module

GuardLogix controllers mdash 1756-L61S 1756-L62S 1756-L63S

mdash mdash

ControlLogix-XT controllers

mdash 1756-L63XT mdash mdash

(1) The 1756-BATM externally mounted battery assembly is highly recommended for use with all series A 1756-L6x controllers and provides longer battery life than the 1756-BA1 battery The 1756-BATM includes one 1756-BATA lithium battery assembly and a 1 m (328 ft) cable to connect housing to controller

32 Publication 1756-SG001P-EN-P - May 2011

Standard Chassis

The chassis backplane provides a high-speed communication path between modules and distributes power to each of the modules within the chassis

ControlLogix-XT Chassis

The ControlLogix-XT chassis support extreme temperature environments

Accessories - Chassis

Use a slot filler module to fill empty slots

Cat No Description Slots

1756-A4 ControlLogix standard chassis 4

1756-A7 7

1756-A10 10

1756-A13 13

1756-A17 17

Cat No Description Slots Temperature Range

1756-A4LXT ControlLogix-XT chassis 4 -2560 degC (-13140 degF)

1756-A5XT 5 -2570 degC (-13158 degF)

1756-A7LXT 7 -2560 degC (-13140 degF)

Cat No Description

1756-N2 Slot filler module for empty slots in standard ControlLogix chassis

1756-N2XT Slot filler module for empty slots in ControlLogix-XT chassis

Publication 1756-SG001P-EN-P - May 2011 33

ControlLogix Power Supplies

ControlLogix power supplies are used with the 1756 chassis to provide 12V 33V 5V and 24V DC power directly to the chassis backplane Select from these configurations

Standard power Redundant power ControlLogix-XT power

For detailed specifications see 1756 ControlLogix Power Supplies Specifications publication 1756-TD005

Standard Power Supplies

You mount a standard power supply directly on the left end of the chassis where it plugs directly into the backplane

ControlLogix-XT Power Supplies

The ControlLogix-XT power supplies support extreme temperature environments

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA72 ControlLogix standard AC 120V220V AC 85hellip265V AC Standard series A and series B

1756-PA75 120V220V AC 85hellip265V AC Standard series B

1756-PB72 ControlLogix standard DC 24V DC 18hellip32V DC Standard series A and series B

1756-PB75 24V DC 1832V DC Standard series B

1756-PC75 48V DC 30hellip60V DC Standard series B

1756-PH75 125V DC 90hellip143V DC Standard series B

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PAXT ControlLogix-XT AC power supply 85265V AC 120240V AC XT

1756-PBXT ControlLogix-XT DC power supply 24V DC 18hellip32V DC XT

34 Publication 1756-SG001P-EN-P - May 2011

Redundant Power Supplies

To build a redundant power supply system you need the following

Two redundant power supplies (both 1756-PA75R or 1756-PB75R) One 1756-PSCA2 chassis adapter module Two 1756-CPR2 cables to connect the power supplies to the

1756-PSCA2 chassis adapter module (091 m (3 ft) length) User-supplied annunciator wiring to connect the power supplies to the

input modules as needed

The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Accessories - Redundant Power Supplies

Visualization Products Visualization products together with Logix for control and NetLinx architecture for communication make up the Rockwell Automation Integrated Architecture strategy The visualization strategy combines Rockwell Automation expertise in Allen-Bradley electronic operator interface and industrialized personal computer hardware with Rockwell Software supervisory control software Current visualization products include the following

FactoryTalk View software PanelView Plus operator interface PanelView Plus CE operator interface Industrial computers and monitors

For more information see the Operator Interface catalog pages at httpwwwabcomenepubcatalogs1276221813761239781

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA75R ControlLogix redundant 120V220V AC 85hellip265V AC Standard series B

1756-PB75R 24V DC 192hellip32V DC Standard series B

Cat No Description Specifications

1756-PSCA2 Chassis adapter module Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Mounts directly to left side of 1756 chassis

1756-CPR2 Chassis adapter cable Connects redundant power supply to 1756-PCSA2 chassis adapter Length091 m (3 ft)

Publication 1756-SG001P-EN-P - May 2011 35

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

ControlLogix Integrated Motion

The Logix architecture supports motion control components that work in a wide variety of machine architectures

Integrated motion on EtherNetIP supports a connection to Ethernet drives

The Kinetix integrated-motion solution uses a SERCOS interface module to perform multi-axis synchronized motion

Logix integrated motion supports the analog family of servo modules for controlling drivesactuators

Networked motion provides the ability to connect via the DeviceNet network to a single axis drive to perform point-to-point indexing

For detailed specifications on motion interface modules see 1756 ControlLogix Integrated Motion Specifications publication 1756-TD004

For more information see these publications

Motion Analyzer CD to size your motion application and to make final component selection Download the software from httpwwwabcommotionsoftwareanalyzerhtml

Kinetix Motion Control Selection Guide publication GMC-SG001 to verify drive motor and accessory specifications

Integrated Motion on an EtherNetIP Network

Product Consideration

Drive that supports EtherNetIP connections Unlimited velocity torque and Vhz configured drives Kinetix 6500 drives PowerFlex 755 drives

ControlLogix controller As many as 100 drives per controller

ControlLogix EtherNetIP communication module 1hellip8 position configured drives with 1756-EN2TR module 1hellip255 position configured drives with 1756-EN3TR module

Publication 1756-SG001P-EN-P - May 2011 15

SERCOS Interface Modules

The SERCOS interface modules can connect to these servo drives

2093 Kinetix 2000 multi-axis servo drive 2094 Kinetix 6000 multi-axis servo drive 2099 Kinetix 7000 high-power servo drive 2098 Ultra3000 SERCOS servo drive

ControlLogix Controller

PanelView Plus Terminal

Workstations

POINT IO ModulesDrive with EtherNetIP Connection

Cat No Description Number of Axis

1756-M16SE Rockwell Automation SERCOS interface modules 16

1756-M08SE 8

1756-M03SE 3

1756-M08SEG SERCOS interface drives that are Extended Pack Profile compliant 8

16 Publication 1756-SG001P-EN-P - May 2011

Analog Motion Interface Modules

RSLogix 5000 Software1756-MxxSE Module

ControlLogix Controller

Three-phase Input Power

Line Interface Module

Integrated Axis Module

Motor Motor Feedback

Axis Modules

Slot Filler Module

Shunt Module

SERCOS Fiber-optic RingKinetix 6000 Multi-axis Servo Drive

Cat No Description Number of Axis

1756-M02AE Analog servo interface drives with quadrature feedback 2

1756-HYD02 Analog hydraulic servo interface drives LDT feedback 2

1756-M02AS Analog servo interface drives with SSI feedback 2

Publication 1756-SG001P-EN-P - May 2011 17

ControlLogix Communication Modules

Separate communication modules are available for different networks Install multiple communication modules into the ControlLogix backplane to bridge or route control and information data between different networks You can route a message through a maximum of four chassis (eight communication hops) You do not need a ControlLogix controller in the chassis

For detailed specifications see 1756 ControlLogix Network Specifications publication 1756-TD003

Application Network Page

Plant management (material handling) Configuration data collection and control on a single high-speed network Time-critical applications with no established schedule Inclusion of commercial technologies (such as video over IP) InternetIntranet connection Integrated CIP motion and safety

EtherNetIP network 19

High-speed transfer of time-critical data between controllers and IO devices Deterministic and repeatable data delivery Media redundancy Intrinsic safety Redundant controller systems

ControlNet network 20

Connections of low-level devices directly to plant floor controllers without interfacing them through IO modules

Data sent as needed More diagnostics for improved data collection and fault detection Less wiring and reduced start-up time than a traditional hard-wired system

DeviceNet network 21

Plant-wide and cell-level data sharing with program maintenance Data sent regularly Transfer of information between controllers

Data Highway Plus network 23

Connections between controllers and IO adapters Data sent regularly Distributed control so that each controller has its own IO and communicates with a

supervisory controller

Remote IO network 23

Fieldbus transmitters and actuators Closed-loop control Process automation

Foundation Fieldbus network 25

18 Publication 1756-SG001P-EN-P - May 2011

EtherNetIP Communication Modules

The Ethernet Industrial (EtherNetIP) network protocol is an open industrial-networking standard that supports both real-time IO messaging and message exchange The EtherNetIP network uses off-the-shelf Ethernet communication chips and physical media

Accessories - EtherNetIP Network

Cat No Description Media Communication Rate

CIP Motion Axes max

TCPIP Connections

Logix Connections

1756-EN2F EtherNetIP bridge fiber Fiber 100 Mbps 8 128 256

1756-EN2T EtherNetIP bridge copper Copper 10100 Mbps 8 128 256

1756-EN2TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 8 128 256

1756-EN3TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 255 128 256

1756-ENBT EtherNetIP bridge copper Copper 10100 Mbps mdash 64 128

1756-EWEB Ethernet web server module Copper 10100 Mbps mdash 64 128

1756-EN2TXT ControlLogix-XT extended temperature EtherNetIP bridge copper for extreme environments

Copper 10100 Mbps 8 128 256

Cat No Description Specifications

1585J-M8PBJM-x Ethernet RJ45 patchcordx = 2 (2 m) 5 (5 m) or 10 (10 m)

8-conductor Teal Riser PVC Cable (Flex Rated cable also available)

1585J-M8CC-H RJ45 insulation displacement connector (IDC) 01280325 mm2 (26hellip22 AWG) Cat 6 IDC no tool required

1585J-M8CC-C RJ45 crimp connector with boot qty = 50 pieces 01280205 mm2 (26hellip24 AWG Cat 5e requires crimp tool for assembly

1585A-Jcrimp Crimp tool mdash

9300-RADES Remote access dial-in kit 56 Kbps modem connection to devices on an Ethernet network includes pre-configured modem communication module DIN rail mounting hardware associated cables

Publication 1756-SG001P-EN-P - May 2011 19

Example Configuration - EtherNetIP Network

ControlNet Communication ModulesThe ControlNet network combines the functionality of an IO network and a peer-to-peer network providing high-speed performance The ControlNet network provides deterministic repeatable transfers of critical control data

FirewallRouter

Stratix Switch

Stratix Switch

Stratix Switch

Powermonitor 3000PowerFlex 70

Ethernet PLC-5

MicroLogix

Ethernet SLC 500

1756 IO

1794 IO

1761-NET-ENI

ControlNet

DeviceNet

1734 IO

RSLinxPanelView Plus

1769-L35E CompactLogix

Cat No Description Communication Rate

Logix Connections Number of Nodes

1756-CN2B ControlNet bridge standard media 5 Mbps 128(1) 99

1756-CN2RB ControlNet bridge redundant media 5 Mbps 128(1) 99

1756-CNB ControlNet bridge standard media 5 Mbps 64(2) 99

1756-CNBR ControlNet bridge redundant media 5 Mbps 64(2) 99

1756-CN2RXT ControlLogix-XT extended temperature ControlNet bridge redundant media

5 Mbps 128(1) 99

(1) 128 connections are available for standard use An additional three connections are reserved for redundant control

(2) Recommend using only 4048 Logix connections for IO

20 Publication 1756-SG001P-EN-P - May 2011

Example Configuration - ControlNet Network

Example Configuration - Redundant ControlNet Media

For information on ControlNet media see ControlNet Media System Components List AG-PA002

DeviceNet Communication Module

The DeviceNet network provides connections between simple industrial devices (such as sensors and actuators) and higher-level devices (such as controllers and computers)

1784-U2CNPanelView Plus

1788-CN2DN

DeviceNetPowerFlex 700SPLC-540CControlLogix

Redundant Media

ControlLogix1756-CNBR

ControlNet Node

ControlNet Node

Cat No Description Communication Rate Number of Nodes

1756-DNB DeviceNet bridge 125 Kbps (500 m max)250 Kbps (250 m max)500 Kbps (100 m max)

64

Publication 1756-SG001P-EN-P - May 2011 21

Example Configuration - DeviceNet Network

Accessories - DeviceNet Network

PLC-51771-SDN ControlLogix

1756-DNB

Ultra3000

PanelView Plus1784-U2DN

Ultra5000

IO

Motor starter

PowerFlex AC

Sensor Pushbuttons

LightsBar Code Scanner

Cat No Description

KwikLink Lite flat media KwikLink Lite flat media is a newer ODVA-approved solution for wiring DeviceNet networks Drop-lines for connecting nodes are added by using the KwikLink Lite two-piece connectors This cable system supports the intermixing of DeviceNet cable types (thin-round with flat) All of the KwikLink Lite connectors provide insulation displacement technology with reduced assembly time

KwikLink flat media The KwikLink flat media system provides a modular cabling method with its flat 4-wire cable and insulation displacement connectors (IDCs) The KwikLink system allows nodes to be added to the network without severing the trunkline Cutting or stripping of the trunkline is eliminated as is the need for predetermined cable lengths

Round media Round trunk cable is available in bulk spools or as pre-molded cordsets or patchcords in varying lengths A wide variety of rugged durable DeviceNet components is available for use in round trunk systems Stainless steel versions of round cable system components are also available Thick-trunk round media systems use thick cable for maximum DeviceNet trunk line length Round media thin-trunk systems use thin cable to reduce maximum trunk line distances with a more

compact and cost-effective installation for some applications Thin-cable outer jacket material is TPE for additional chemical resistance

22 Publication 1756-SG001P-EN-P - May 2011

Data Highway Plus and Remote IO Communication Modules

The Data Highway Plus network supports messaging between devices The remote IO link connects to remote IO chassis and other intelligent devices

The 1756-DHRIO module supports messaging between devices on DH+ networks The remote IO functionality enables the module to act as a scanner for transferring digital and block-transfer data to and from remote IO devices

The 1756-RIO module can act as a scanner or adapter on a remote IO network In addition to digital and block-transfer data the 1756-RIO module transfers analog and specialty data without message instructions

Cat No Description Communication Rate DH+ Connections RIO Connections Maximum Recommended Logix Connections

1756-DHRIO Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

1756-RIO Remote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

mdash Remote IO scanner or adapter32 physical racks (076) any combination of rack size and block transfers

10 scheduled IO

1756-DHRIOXT ControlLogix-XT extended temperature Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

Publication 1756-SG001P-EN-P - May 2011 23

Example Configuration - DH+ Network

Example Configuration - Remote IO Network

Accessories - DH+ and Remote IO Networks

PanelView Plus

PLC-5 1784-U2DHPRSLogix 5000

ControlLogix1756-DHRIO

SLC 504

PanelView PlusPLC-5

1791 IO1794 IO

1756-RIO as a Remote IO Adapter

1756-DHRIO as a Remote IO Scanner

Cat No Description Specifications

1770-CD Cable to connect communication module to DH+ network Belden 9463 twinaxial

9300-RADKIT Remote access dial-in kit 56 Kbps modem connection to devices on a DH+ network includes pre-configured modem communication module DIN rail mounting hardware associated cables

24 Publication 1756-SG001P-EN-P - May 2011

FOUNDATION Fieldbus Linking Devices

The FOUNDATION Fieldbus protocol is a network designed for distributed control of process applications

Example Configuration - Bridge to EtherNetIP Network

Cat No Description Communication Rate Number of H1 Ports

Devices per H1 Link

Devices per Linking Device

1757FFLD2 FOUNDATION Fieldbus bridge to an Ethernet network

FOUNDATION Fieldbus 3125 KbpsEtherNetIP 10100 Mbps

2 16(8hellip10 recommended)

32

1757-FFLD4 4 64

1757-FFLDC2 FOUNDATION Fieldbus bridge to a ControlNet network

FOUNDATION Fieldbus 3125 KbpsControlNet 5 Mbps

2 16(8hellip10 recommended)

32

1757-FFLDC4 4 64

FactoryTalk View SERSFieldbusRSLogix 5000

1757-FFLD4

H1(1)

H1(2)H1(3)H1(4)

HSEIP

Publication 1756-SG001P-EN-P - May 2011 25

Example Configuration - Bridge to ControlNet Network

Other Connectivity Options

ControlLogix RedundancyFactoryTalk View SERSFieldbusRSLogix 5000

ControlNet Redundant Media

1757-FFLDC2

FF H1

EtherNetIP

Option Consideration

USB connection The 1756-L7x controller has a USB port in place of the serial port If your application requires RS-232 functionality see the many Encompass partners at httpwwwrockwellautomationcomencompass

Serial connection The serial port on the 1756-L6x controller is compatible with RS-232 serial communication The serial port supports the DF1 protocol to communicate with other devices on the serial linkTo use Logix5000 controllers on Modbus you connect through the serial port and execute a specific ladder logic routine The controller project is available with RSLogix 5000 Enterprise programming software For more information see Using Logix5000 Controllers as Masters or Slaves on Modbus Application Solution publication CIG-AP129

DH-485 network The controller serial port is compatible with DH-485 communication The DH-485 connection does support remote programming and monitoring via RSLogix 5000 softwareOr add a DH-485 communication bridge module (cat no 1756-DH485)

SynchLink network The SynchLink communication module (1756-SYNCH) provides time synchronization and data broadcasting capabilities for distributed motion and coordinated drive control The module connects a ControlLogix chassis to a SynchLink fiber-optic communication link

26 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Controllers The ControlLogix controller provides a scalable controller solution that is capable of addressing a large amount of IO points

The controller can be placed into any slot of a ControlLogix chassis and multiple controllers can be installed in the same chassis Multiple controllers in the same chassis communicate with each other over the backplane (just as controllers can communicate over networks) but operate independently

ControlLogix controllers can monitor and control IO across the ControlLogix backplane as well as over IO links ControlLogix controllers can communicate over EtherNetIP ControlNet DeviceNet DH+ Remote IO and RS-232-C (DF1DH-485 protocol) networks and many third party process and device networks To provide communication for a ControlLogix controller install the appropriate communication interface module into the chassis

For detailed specifications see 1756 ControlLogix Controllers Specifications publication 1756-TD001

Cat No Description User Memory

1756-L72 ControlLogix controller 1 built-in USB port 4 MB

1756-L73 8 MB

1756-L74 16 MB

1756-L75 32 MB

1756-L61 ControlLogix controller 1 built-in RS-232 port 2 MB

1756-L62 4 MB

1756-L63 8 MB

1756-L64 16 MB

1756-L65 32 MB

1756-L61S GuardLogix safety controller 2 MB standard1 MB safety

1756-L62S 4 MB standard1 MB safety

1756-L63S 8 MB standard375 MB safety

1756-LSP GuardLogix safety partner (one is required for each GuardLogix controller) mdash

1756-L63XT ControlLogix-XT controller extreme environment 8 MB

IMPORTANT Scan time for a project loaded in a 1756-L64 or 1756-L65 controller may be slower than for the same project loaded in one of the other 1756-L6x controllers See the Logix5000 Controllers Instruction Execution Time and Memory Use Reference Manual publication 1756-RM087 for instruction execution times

Publication 1756-SG001P-EN-P - May 2011 27

Standard ControlLogix Controllers

The ControlLogix controller is part of the Logix5000 family of controllers A ControlLogix system includes the following

The ControlLogix controller available in different combinations of user memory

RSLogix 5000 programming software 1756 ControlLogix IO modules that reside in a 1756 chassis Separate communication modules for network communication

Features - Standard ControlLogix Controllers

Feature 1756-L61 1756-L62 1756-L63 1756-L64 1756-L65

1756-L72 1756-L73 1756-L74 1756-L75

Controller tasks 32 tasks 100 programstask Event tasks all event triggers

Built-in communication ports 1 port RS-232 serial 1 port USB

Communication options EtherNetIP ControlNet DeviceNet Data Highway Plus Remote IO SynchLink Third-party process and device networks

Built-in port Serial USB

Controller connections supported max 250 500

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Full support

Integrated motion EtherNetIP connection SERCOS interface Analog options (encoder input LDT input SSI input)

Programming languages Relay ladder Structured text Function block SFC

28 Publication 1756-SG001P-EN-P - May 2011

GuardLogix Controllers

A GuardLogix controller is a ControlLogix controller that also provides safety control The GuardLogix system is a dual controller solutionmdashyou must use a 1756-L6xS primary controller and a 1756-LSP safety partner to achieve SIL 3CAT 4

During development safety and standard have the same rules multiple programmers online editing and forcing are all allowed Once the project is tested and ready for final validation you set the Safety Task to a SIL 3 integrity level which is then enforced by the GuardLogix controller When safety memory is locked and protected the safety logic cant be modified and all safety functions operate with SIL 3 integrity On the standard side of the GuardLogix controller all functions operate like a regular Logix controller

Use Guard IO modules for field device connectivity on Ethernet or DeviceNet networks and for safety interlocking between GuardLogix controllers use Ethernet or ControlNet networks Multiple GuardLogix controllers can share safety data for zone to zone interlocking or a single GuardLogix controller can use remote distributed safety IO between different cellsareas

In addition to the standard features of a ControlLogix controller the GuardLogix controller has these safety-related features

Application Description

SIL 1 2 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508 and applications up to and including PLeCat4 according to ISO 13849-1 For more information see GuardLogix Controllers Systems Safety Reference Manual publication 1756-RM093 GuardLogix Controllers User Manual publication 1756-UM020 GuardLogix Safety Application Instruction Set Reference Manual publication 1756-RM095

Features - GuardLogix Controllers

Feature 1756-L61S 1756-L62S 1756-L63S 1756-LSP

Safety communication options Standard and safety EtherNetIP ControlNet DeviceNet

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Not supported

Programming languages Relay ladder

Publication 1756-SG001P-EN-P - May 2011 29

ControlLogix-XT Controllers

The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh corrosive environments

When used with FLEX IO-XT products the ControlLogix-XT system can withstand temperatures range from -2070 C (-4158 F)

When used independently the ControlLogix-XT system can withstand temperature ranges from -2570 C (-13158 F)

Redundant ControlLogix Controllers

The ControlLogix controller supports controller redundancy In a redundant controller system you need these components

Two 1756 chassis each with the following the same ndash Number of slots

ndash Modules in the same slots

ndash Redundancy firmware revisions in each module

ndash Two additional ControlNet nodes outside the redundant chassis pair

You need one of these redundancy modules

One 1756-RM module per chassis that supports the followingndash Two 1756-L61 1756-L62 1761-L63 controllers or one 1756-L64

controller

ndash Maximum of seven communication modules which can be 1756-CN2 series B 1756-CN2R series B and 1756-EN2T modules

ndash One 1756-RMCx cable

One 1757-SRM module per chassis that supports the followingndash One 1756-L61 1756-L62 1756-L63 1756-L64 controller

ndash Maximum of seven communication modules which can be 1756-CNB series D or E 1756-CNBR series D or E 1756-ENBT and 1756-EWEB modules

ndash One 1757-SRCx cable

30 Publication 1756-SG001P-EN-P - May 2011

Accessories - Controllers

Memory Cards

Memory cards offer nonvolatile memory to permanently store a user program and tag data on a controller The 1756-L7x ControlLogix controller comes with 1784-SD1 Secure Digital (SD) card already installed The 1756-L6x controllers support optional CompactFlash cards that you purchase separately The memory card installs in a socket on the controller Through RSLogix 5000 software you can manually trigger the controller to save to or load from nonvolatile memory or configure the controller to load from nonvolatile memory on powerup

The GuardLogix controller does not support user program storage or retrieval by using a CompactFlash card

1756 Energy Storage Modules

Instead of a battery the 1756-L7x controller ships with a 1756-ESMCAP energy storage module (ESM) already installed

Attribute 1784-CF64 1784-CF128 1784-SD1 1784-SD2

Memory 64 MB 128 MB 1 GB 2 GB

Supported controllers 1756-L6x 1756-L7x

Weight approx 142 g (05 oz) 176 g (0062 oz)

Cat No Description

1756-ESMCAP Capacitor-based energy-storage module Comes with the controller

1756-EMNSE ESM without WallClockTime backup power Additionally you can use this ESM with a 1756-L73 (8 MB) or smaller memory-sized controller only

Use this ESM if your application requires that the installed ESM deplete its residual energy to 40 microJoule or less before transporting it into or out of your application

1756-ESMNRM Energy-storage module that secures the controller by preventing the USB connection and SD card useThis ESM provides your application an enhanced degree of security

Publication 1756-SG001P-EN-P - May 2011 31

1756 ControlLogix Batteries

Each 1756-L6x controller ships with a battery With a memory card installed the controller can be used without a battery If you do not use a battery current tag data will be at the state it was when the memory card was saved

ControlLogix Chassis The ControlLogix system is a modular system that requires a 1756 IO chassis Place any module into any slot The backplane provides a high-speed communication path between modules

All of the chassis are designed for horizontal-only back-panel mounting The chassis are available in these configurations

Standard chassis ControlLogix-XT chassis

For detailed specifications see 1756 ControlLogix Chassis Specifications Specifications publication 1756-TD006

Features - Chassis

Slot guides and snap-in retention for easy and secure module fit for any type of 1756 module

Direct mounting accommodates any 1756 power supply

Attribute 1756-BA1 1756-BA2 1756-BATM(1) 1756-BATA

Description Lithium battery (059 g) Lithium battery (059 g) Externally mounted battery assembly

Replacement lithium battery for 1756-BATM (5 g max lithium per each D cell contains 2 D cells)

ControlLogix controllers 1756-L61 1756-L62 1756-L63 series A

1756-L61 1756-L62 1756-L63 series B1756-L64 1756-L65

1756-L61 1756-L62 1756-L63 series A

1756-BATM battery module

GuardLogix controllers mdash 1756-L61S 1756-L62S 1756-L63S

mdash mdash

ControlLogix-XT controllers

mdash 1756-L63XT mdash mdash

(1) The 1756-BATM externally mounted battery assembly is highly recommended for use with all series A 1756-L6x controllers and provides longer battery life than the 1756-BA1 battery The 1756-BATM includes one 1756-BATA lithium battery assembly and a 1 m (328 ft) cable to connect housing to controller

32 Publication 1756-SG001P-EN-P - May 2011

Standard Chassis

The chassis backplane provides a high-speed communication path between modules and distributes power to each of the modules within the chassis

ControlLogix-XT Chassis

The ControlLogix-XT chassis support extreme temperature environments

Accessories - Chassis

Use a slot filler module to fill empty slots

Cat No Description Slots

1756-A4 ControlLogix standard chassis 4

1756-A7 7

1756-A10 10

1756-A13 13

1756-A17 17

Cat No Description Slots Temperature Range

1756-A4LXT ControlLogix-XT chassis 4 -2560 degC (-13140 degF)

1756-A5XT 5 -2570 degC (-13158 degF)

1756-A7LXT 7 -2560 degC (-13140 degF)

Cat No Description

1756-N2 Slot filler module for empty slots in standard ControlLogix chassis

1756-N2XT Slot filler module for empty slots in ControlLogix-XT chassis

Publication 1756-SG001P-EN-P - May 2011 33

ControlLogix Power Supplies

ControlLogix power supplies are used with the 1756 chassis to provide 12V 33V 5V and 24V DC power directly to the chassis backplane Select from these configurations

Standard power Redundant power ControlLogix-XT power

For detailed specifications see 1756 ControlLogix Power Supplies Specifications publication 1756-TD005

Standard Power Supplies

You mount a standard power supply directly on the left end of the chassis where it plugs directly into the backplane

ControlLogix-XT Power Supplies

The ControlLogix-XT power supplies support extreme temperature environments

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA72 ControlLogix standard AC 120V220V AC 85hellip265V AC Standard series A and series B

1756-PA75 120V220V AC 85hellip265V AC Standard series B

1756-PB72 ControlLogix standard DC 24V DC 18hellip32V DC Standard series A and series B

1756-PB75 24V DC 1832V DC Standard series B

1756-PC75 48V DC 30hellip60V DC Standard series B

1756-PH75 125V DC 90hellip143V DC Standard series B

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PAXT ControlLogix-XT AC power supply 85265V AC 120240V AC XT

1756-PBXT ControlLogix-XT DC power supply 24V DC 18hellip32V DC XT

34 Publication 1756-SG001P-EN-P - May 2011

Redundant Power Supplies

To build a redundant power supply system you need the following

Two redundant power supplies (both 1756-PA75R or 1756-PB75R) One 1756-PSCA2 chassis adapter module Two 1756-CPR2 cables to connect the power supplies to the

1756-PSCA2 chassis adapter module (091 m (3 ft) length) User-supplied annunciator wiring to connect the power supplies to the

input modules as needed

The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Accessories - Redundant Power Supplies

Visualization Products Visualization products together with Logix for control and NetLinx architecture for communication make up the Rockwell Automation Integrated Architecture strategy The visualization strategy combines Rockwell Automation expertise in Allen-Bradley electronic operator interface and industrialized personal computer hardware with Rockwell Software supervisory control software Current visualization products include the following

FactoryTalk View software PanelView Plus operator interface PanelView Plus CE operator interface Industrial computers and monitors

For more information see the Operator Interface catalog pages at httpwwwabcomenepubcatalogs1276221813761239781

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA75R ControlLogix redundant 120V220V AC 85hellip265V AC Standard series B

1756-PB75R 24V DC 192hellip32V DC Standard series B

Cat No Description Specifications

1756-PSCA2 Chassis adapter module Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Mounts directly to left side of 1756 chassis

1756-CPR2 Chassis adapter cable Connects redundant power supply to 1756-PCSA2 chassis adapter Length091 m (3 ft)

Publication 1756-SG001P-EN-P - May 2011 35

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

SERCOS Interface Modules

The SERCOS interface modules can connect to these servo drives

2093 Kinetix 2000 multi-axis servo drive 2094 Kinetix 6000 multi-axis servo drive 2099 Kinetix 7000 high-power servo drive 2098 Ultra3000 SERCOS servo drive

ControlLogix Controller

PanelView Plus Terminal

Workstations

POINT IO ModulesDrive with EtherNetIP Connection

Cat No Description Number of Axis

1756-M16SE Rockwell Automation SERCOS interface modules 16

1756-M08SE 8

1756-M03SE 3

1756-M08SEG SERCOS interface drives that are Extended Pack Profile compliant 8

16 Publication 1756-SG001P-EN-P - May 2011

Analog Motion Interface Modules

RSLogix 5000 Software1756-MxxSE Module

ControlLogix Controller

Three-phase Input Power

Line Interface Module

Integrated Axis Module

Motor Motor Feedback

Axis Modules

Slot Filler Module

Shunt Module

SERCOS Fiber-optic RingKinetix 6000 Multi-axis Servo Drive

Cat No Description Number of Axis

1756-M02AE Analog servo interface drives with quadrature feedback 2

1756-HYD02 Analog hydraulic servo interface drives LDT feedback 2

1756-M02AS Analog servo interface drives with SSI feedback 2

Publication 1756-SG001P-EN-P - May 2011 17

ControlLogix Communication Modules

Separate communication modules are available for different networks Install multiple communication modules into the ControlLogix backplane to bridge or route control and information data between different networks You can route a message through a maximum of four chassis (eight communication hops) You do not need a ControlLogix controller in the chassis

For detailed specifications see 1756 ControlLogix Network Specifications publication 1756-TD003

Application Network Page

Plant management (material handling) Configuration data collection and control on a single high-speed network Time-critical applications with no established schedule Inclusion of commercial technologies (such as video over IP) InternetIntranet connection Integrated CIP motion and safety

EtherNetIP network 19

High-speed transfer of time-critical data between controllers and IO devices Deterministic and repeatable data delivery Media redundancy Intrinsic safety Redundant controller systems

ControlNet network 20

Connections of low-level devices directly to plant floor controllers without interfacing them through IO modules

Data sent as needed More diagnostics for improved data collection and fault detection Less wiring and reduced start-up time than a traditional hard-wired system

DeviceNet network 21

Plant-wide and cell-level data sharing with program maintenance Data sent regularly Transfer of information between controllers

Data Highway Plus network 23

Connections between controllers and IO adapters Data sent regularly Distributed control so that each controller has its own IO and communicates with a

supervisory controller

Remote IO network 23

Fieldbus transmitters and actuators Closed-loop control Process automation

Foundation Fieldbus network 25

18 Publication 1756-SG001P-EN-P - May 2011

EtherNetIP Communication Modules

The Ethernet Industrial (EtherNetIP) network protocol is an open industrial-networking standard that supports both real-time IO messaging and message exchange The EtherNetIP network uses off-the-shelf Ethernet communication chips and physical media

Accessories - EtherNetIP Network

Cat No Description Media Communication Rate

CIP Motion Axes max

TCPIP Connections

Logix Connections

1756-EN2F EtherNetIP bridge fiber Fiber 100 Mbps 8 128 256

1756-EN2T EtherNetIP bridge copper Copper 10100 Mbps 8 128 256

1756-EN2TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 8 128 256

1756-EN3TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 255 128 256

1756-ENBT EtherNetIP bridge copper Copper 10100 Mbps mdash 64 128

1756-EWEB Ethernet web server module Copper 10100 Mbps mdash 64 128

1756-EN2TXT ControlLogix-XT extended temperature EtherNetIP bridge copper for extreme environments

Copper 10100 Mbps 8 128 256

Cat No Description Specifications

1585J-M8PBJM-x Ethernet RJ45 patchcordx = 2 (2 m) 5 (5 m) or 10 (10 m)

8-conductor Teal Riser PVC Cable (Flex Rated cable also available)

1585J-M8CC-H RJ45 insulation displacement connector (IDC) 01280325 mm2 (26hellip22 AWG) Cat 6 IDC no tool required

1585J-M8CC-C RJ45 crimp connector with boot qty = 50 pieces 01280205 mm2 (26hellip24 AWG Cat 5e requires crimp tool for assembly

1585A-Jcrimp Crimp tool mdash

9300-RADES Remote access dial-in kit 56 Kbps modem connection to devices on an Ethernet network includes pre-configured modem communication module DIN rail mounting hardware associated cables

Publication 1756-SG001P-EN-P - May 2011 19

Example Configuration - EtherNetIP Network

ControlNet Communication ModulesThe ControlNet network combines the functionality of an IO network and a peer-to-peer network providing high-speed performance The ControlNet network provides deterministic repeatable transfers of critical control data

FirewallRouter

Stratix Switch

Stratix Switch

Stratix Switch

Powermonitor 3000PowerFlex 70

Ethernet PLC-5

MicroLogix

Ethernet SLC 500

1756 IO

1794 IO

1761-NET-ENI

ControlNet

DeviceNet

1734 IO

RSLinxPanelView Plus

1769-L35E CompactLogix

Cat No Description Communication Rate

Logix Connections Number of Nodes

1756-CN2B ControlNet bridge standard media 5 Mbps 128(1) 99

1756-CN2RB ControlNet bridge redundant media 5 Mbps 128(1) 99

1756-CNB ControlNet bridge standard media 5 Mbps 64(2) 99

1756-CNBR ControlNet bridge redundant media 5 Mbps 64(2) 99

1756-CN2RXT ControlLogix-XT extended temperature ControlNet bridge redundant media

5 Mbps 128(1) 99

(1) 128 connections are available for standard use An additional three connections are reserved for redundant control

(2) Recommend using only 4048 Logix connections for IO

20 Publication 1756-SG001P-EN-P - May 2011

Example Configuration - ControlNet Network

Example Configuration - Redundant ControlNet Media

For information on ControlNet media see ControlNet Media System Components List AG-PA002

DeviceNet Communication Module

The DeviceNet network provides connections between simple industrial devices (such as sensors and actuators) and higher-level devices (such as controllers and computers)

1784-U2CNPanelView Plus

1788-CN2DN

DeviceNetPowerFlex 700SPLC-540CControlLogix

Redundant Media

ControlLogix1756-CNBR

ControlNet Node

ControlNet Node

Cat No Description Communication Rate Number of Nodes

1756-DNB DeviceNet bridge 125 Kbps (500 m max)250 Kbps (250 m max)500 Kbps (100 m max)

64

Publication 1756-SG001P-EN-P - May 2011 21

Example Configuration - DeviceNet Network

Accessories - DeviceNet Network

PLC-51771-SDN ControlLogix

1756-DNB

Ultra3000

PanelView Plus1784-U2DN

Ultra5000

IO

Motor starter

PowerFlex AC

Sensor Pushbuttons

LightsBar Code Scanner

Cat No Description

KwikLink Lite flat media KwikLink Lite flat media is a newer ODVA-approved solution for wiring DeviceNet networks Drop-lines for connecting nodes are added by using the KwikLink Lite two-piece connectors This cable system supports the intermixing of DeviceNet cable types (thin-round with flat) All of the KwikLink Lite connectors provide insulation displacement technology with reduced assembly time

KwikLink flat media The KwikLink flat media system provides a modular cabling method with its flat 4-wire cable and insulation displacement connectors (IDCs) The KwikLink system allows nodes to be added to the network without severing the trunkline Cutting or stripping of the trunkline is eliminated as is the need for predetermined cable lengths

Round media Round trunk cable is available in bulk spools or as pre-molded cordsets or patchcords in varying lengths A wide variety of rugged durable DeviceNet components is available for use in round trunk systems Stainless steel versions of round cable system components are also available Thick-trunk round media systems use thick cable for maximum DeviceNet trunk line length Round media thin-trunk systems use thin cable to reduce maximum trunk line distances with a more

compact and cost-effective installation for some applications Thin-cable outer jacket material is TPE for additional chemical resistance

22 Publication 1756-SG001P-EN-P - May 2011

Data Highway Plus and Remote IO Communication Modules

The Data Highway Plus network supports messaging between devices The remote IO link connects to remote IO chassis and other intelligent devices

The 1756-DHRIO module supports messaging between devices on DH+ networks The remote IO functionality enables the module to act as a scanner for transferring digital and block-transfer data to and from remote IO devices

The 1756-RIO module can act as a scanner or adapter on a remote IO network In addition to digital and block-transfer data the 1756-RIO module transfers analog and specialty data without message instructions

Cat No Description Communication Rate DH+ Connections RIO Connections Maximum Recommended Logix Connections

1756-DHRIO Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

1756-RIO Remote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

mdash Remote IO scanner or adapter32 physical racks (076) any combination of rack size and block transfers

10 scheduled IO

1756-DHRIOXT ControlLogix-XT extended temperature Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

Publication 1756-SG001P-EN-P - May 2011 23

Example Configuration - DH+ Network

Example Configuration - Remote IO Network

Accessories - DH+ and Remote IO Networks

PanelView Plus

PLC-5 1784-U2DHPRSLogix 5000

ControlLogix1756-DHRIO

SLC 504

PanelView PlusPLC-5

1791 IO1794 IO

1756-RIO as a Remote IO Adapter

1756-DHRIO as a Remote IO Scanner

Cat No Description Specifications

1770-CD Cable to connect communication module to DH+ network Belden 9463 twinaxial

9300-RADKIT Remote access dial-in kit 56 Kbps modem connection to devices on a DH+ network includes pre-configured modem communication module DIN rail mounting hardware associated cables

24 Publication 1756-SG001P-EN-P - May 2011

FOUNDATION Fieldbus Linking Devices

The FOUNDATION Fieldbus protocol is a network designed for distributed control of process applications

Example Configuration - Bridge to EtherNetIP Network

Cat No Description Communication Rate Number of H1 Ports

Devices per H1 Link

Devices per Linking Device

1757FFLD2 FOUNDATION Fieldbus bridge to an Ethernet network

FOUNDATION Fieldbus 3125 KbpsEtherNetIP 10100 Mbps

2 16(8hellip10 recommended)

32

1757-FFLD4 4 64

1757-FFLDC2 FOUNDATION Fieldbus bridge to a ControlNet network

FOUNDATION Fieldbus 3125 KbpsControlNet 5 Mbps

2 16(8hellip10 recommended)

32

1757-FFLDC4 4 64

FactoryTalk View SERSFieldbusRSLogix 5000

1757-FFLD4

H1(1)

H1(2)H1(3)H1(4)

HSEIP

Publication 1756-SG001P-EN-P - May 2011 25

Example Configuration - Bridge to ControlNet Network

Other Connectivity Options

ControlLogix RedundancyFactoryTalk View SERSFieldbusRSLogix 5000

ControlNet Redundant Media

1757-FFLDC2

FF H1

EtherNetIP

Option Consideration

USB connection The 1756-L7x controller has a USB port in place of the serial port If your application requires RS-232 functionality see the many Encompass partners at httpwwwrockwellautomationcomencompass

Serial connection The serial port on the 1756-L6x controller is compatible with RS-232 serial communication The serial port supports the DF1 protocol to communicate with other devices on the serial linkTo use Logix5000 controllers on Modbus you connect through the serial port and execute a specific ladder logic routine The controller project is available with RSLogix 5000 Enterprise programming software For more information see Using Logix5000 Controllers as Masters or Slaves on Modbus Application Solution publication CIG-AP129

DH-485 network The controller serial port is compatible with DH-485 communication The DH-485 connection does support remote programming and monitoring via RSLogix 5000 softwareOr add a DH-485 communication bridge module (cat no 1756-DH485)

SynchLink network The SynchLink communication module (1756-SYNCH) provides time synchronization and data broadcasting capabilities for distributed motion and coordinated drive control The module connects a ControlLogix chassis to a SynchLink fiber-optic communication link

26 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Controllers The ControlLogix controller provides a scalable controller solution that is capable of addressing a large amount of IO points

The controller can be placed into any slot of a ControlLogix chassis and multiple controllers can be installed in the same chassis Multiple controllers in the same chassis communicate with each other over the backplane (just as controllers can communicate over networks) but operate independently

ControlLogix controllers can monitor and control IO across the ControlLogix backplane as well as over IO links ControlLogix controllers can communicate over EtherNetIP ControlNet DeviceNet DH+ Remote IO and RS-232-C (DF1DH-485 protocol) networks and many third party process and device networks To provide communication for a ControlLogix controller install the appropriate communication interface module into the chassis

For detailed specifications see 1756 ControlLogix Controllers Specifications publication 1756-TD001

Cat No Description User Memory

1756-L72 ControlLogix controller 1 built-in USB port 4 MB

1756-L73 8 MB

1756-L74 16 MB

1756-L75 32 MB

1756-L61 ControlLogix controller 1 built-in RS-232 port 2 MB

1756-L62 4 MB

1756-L63 8 MB

1756-L64 16 MB

1756-L65 32 MB

1756-L61S GuardLogix safety controller 2 MB standard1 MB safety

1756-L62S 4 MB standard1 MB safety

1756-L63S 8 MB standard375 MB safety

1756-LSP GuardLogix safety partner (one is required for each GuardLogix controller) mdash

1756-L63XT ControlLogix-XT controller extreme environment 8 MB

IMPORTANT Scan time for a project loaded in a 1756-L64 or 1756-L65 controller may be slower than for the same project loaded in one of the other 1756-L6x controllers See the Logix5000 Controllers Instruction Execution Time and Memory Use Reference Manual publication 1756-RM087 for instruction execution times

Publication 1756-SG001P-EN-P - May 2011 27

Standard ControlLogix Controllers

The ControlLogix controller is part of the Logix5000 family of controllers A ControlLogix system includes the following

The ControlLogix controller available in different combinations of user memory

RSLogix 5000 programming software 1756 ControlLogix IO modules that reside in a 1756 chassis Separate communication modules for network communication

Features - Standard ControlLogix Controllers

Feature 1756-L61 1756-L62 1756-L63 1756-L64 1756-L65

1756-L72 1756-L73 1756-L74 1756-L75

Controller tasks 32 tasks 100 programstask Event tasks all event triggers

Built-in communication ports 1 port RS-232 serial 1 port USB

Communication options EtherNetIP ControlNet DeviceNet Data Highway Plus Remote IO SynchLink Third-party process and device networks

Built-in port Serial USB

Controller connections supported max 250 500

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Full support

Integrated motion EtherNetIP connection SERCOS interface Analog options (encoder input LDT input SSI input)

Programming languages Relay ladder Structured text Function block SFC

28 Publication 1756-SG001P-EN-P - May 2011

GuardLogix Controllers

A GuardLogix controller is a ControlLogix controller that also provides safety control The GuardLogix system is a dual controller solutionmdashyou must use a 1756-L6xS primary controller and a 1756-LSP safety partner to achieve SIL 3CAT 4

During development safety and standard have the same rules multiple programmers online editing and forcing are all allowed Once the project is tested and ready for final validation you set the Safety Task to a SIL 3 integrity level which is then enforced by the GuardLogix controller When safety memory is locked and protected the safety logic cant be modified and all safety functions operate with SIL 3 integrity On the standard side of the GuardLogix controller all functions operate like a regular Logix controller

Use Guard IO modules for field device connectivity on Ethernet or DeviceNet networks and for safety interlocking between GuardLogix controllers use Ethernet or ControlNet networks Multiple GuardLogix controllers can share safety data for zone to zone interlocking or a single GuardLogix controller can use remote distributed safety IO between different cellsareas

In addition to the standard features of a ControlLogix controller the GuardLogix controller has these safety-related features

Application Description

SIL 1 2 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508 and applications up to and including PLeCat4 according to ISO 13849-1 For more information see GuardLogix Controllers Systems Safety Reference Manual publication 1756-RM093 GuardLogix Controllers User Manual publication 1756-UM020 GuardLogix Safety Application Instruction Set Reference Manual publication 1756-RM095

Features - GuardLogix Controllers

Feature 1756-L61S 1756-L62S 1756-L63S 1756-LSP

Safety communication options Standard and safety EtherNetIP ControlNet DeviceNet

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Not supported

Programming languages Relay ladder

Publication 1756-SG001P-EN-P - May 2011 29

ControlLogix-XT Controllers

The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh corrosive environments

When used with FLEX IO-XT products the ControlLogix-XT system can withstand temperatures range from -2070 C (-4158 F)

When used independently the ControlLogix-XT system can withstand temperature ranges from -2570 C (-13158 F)

Redundant ControlLogix Controllers

The ControlLogix controller supports controller redundancy In a redundant controller system you need these components

Two 1756 chassis each with the following the same ndash Number of slots

ndash Modules in the same slots

ndash Redundancy firmware revisions in each module

ndash Two additional ControlNet nodes outside the redundant chassis pair

You need one of these redundancy modules

One 1756-RM module per chassis that supports the followingndash Two 1756-L61 1756-L62 1761-L63 controllers or one 1756-L64

controller

ndash Maximum of seven communication modules which can be 1756-CN2 series B 1756-CN2R series B and 1756-EN2T modules

ndash One 1756-RMCx cable

One 1757-SRM module per chassis that supports the followingndash One 1756-L61 1756-L62 1756-L63 1756-L64 controller

ndash Maximum of seven communication modules which can be 1756-CNB series D or E 1756-CNBR series D or E 1756-ENBT and 1756-EWEB modules

ndash One 1757-SRCx cable

30 Publication 1756-SG001P-EN-P - May 2011

Accessories - Controllers

Memory Cards

Memory cards offer nonvolatile memory to permanently store a user program and tag data on a controller The 1756-L7x ControlLogix controller comes with 1784-SD1 Secure Digital (SD) card already installed The 1756-L6x controllers support optional CompactFlash cards that you purchase separately The memory card installs in a socket on the controller Through RSLogix 5000 software you can manually trigger the controller to save to or load from nonvolatile memory or configure the controller to load from nonvolatile memory on powerup

The GuardLogix controller does not support user program storage or retrieval by using a CompactFlash card

1756 Energy Storage Modules

Instead of a battery the 1756-L7x controller ships with a 1756-ESMCAP energy storage module (ESM) already installed

Attribute 1784-CF64 1784-CF128 1784-SD1 1784-SD2

Memory 64 MB 128 MB 1 GB 2 GB

Supported controllers 1756-L6x 1756-L7x

Weight approx 142 g (05 oz) 176 g (0062 oz)

Cat No Description

1756-ESMCAP Capacitor-based energy-storage module Comes with the controller

1756-EMNSE ESM without WallClockTime backup power Additionally you can use this ESM with a 1756-L73 (8 MB) or smaller memory-sized controller only

Use this ESM if your application requires that the installed ESM deplete its residual energy to 40 microJoule or less before transporting it into or out of your application

1756-ESMNRM Energy-storage module that secures the controller by preventing the USB connection and SD card useThis ESM provides your application an enhanced degree of security

Publication 1756-SG001P-EN-P - May 2011 31

1756 ControlLogix Batteries

Each 1756-L6x controller ships with a battery With a memory card installed the controller can be used without a battery If you do not use a battery current tag data will be at the state it was when the memory card was saved

ControlLogix Chassis The ControlLogix system is a modular system that requires a 1756 IO chassis Place any module into any slot The backplane provides a high-speed communication path between modules

All of the chassis are designed for horizontal-only back-panel mounting The chassis are available in these configurations

Standard chassis ControlLogix-XT chassis

For detailed specifications see 1756 ControlLogix Chassis Specifications Specifications publication 1756-TD006

Features - Chassis

Slot guides and snap-in retention for easy and secure module fit for any type of 1756 module

Direct mounting accommodates any 1756 power supply

Attribute 1756-BA1 1756-BA2 1756-BATM(1) 1756-BATA

Description Lithium battery (059 g) Lithium battery (059 g) Externally mounted battery assembly

Replacement lithium battery for 1756-BATM (5 g max lithium per each D cell contains 2 D cells)

ControlLogix controllers 1756-L61 1756-L62 1756-L63 series A

1756-L61 1756-L62 1756-L63 series B1756-L64 1756-L65

1756-L61 1756-L62 1756-L63 series A

1756-BATM battery module

GuardLogix controllers mdash 1756-L61S 1756-L62S 1756-L63S

mdash mdash

ControlLogix-XT controllers

mdash 1756-L63XT mdash mdash

(1) The 1756-BATM externally mounted battery assembly is highly recommended for use with all series A 1756-L6x controllers and provides longer battery life than the 1756-BA1 battery The 1756-BATM includes one 1756-BATA lithium battery assembly and a 1 m (328 ft) cable to connect housing to controller

32 Publication 1756-SG001P-EN-P - May 2011

Standard Chassis

The chassis backplane provides a high-speed communication path between modules and distributes power to each of the modules within the chassis

ControlLogix-XT Chassis

The ControlLogix-XT chassis support extreme temperature environments

Accessories - Chassis

Use a slot filler module to fill empty slots

Cat No Description Slots

1756-A4 ControlLogix standard chassis 4

1756-A7 7

1756-A10 10

1756-A13 13

1756-A17 17

Cat No Description Slots Temperature Range

1756-A4LXT ControlLogix-XT chassis 4 -2560 degC (-13140 degF)

1756-A5XT 5 -2570 degC (-13158 degF)

1756-A7LXT 7 -2560 degC (-13140 degF)

Cat No Description

1756-N2 Slot filler module for empty slots in standard ControlLogix chassis

1756-N2XT Slot filler module for empty slots in ControlLogix-XT chassis

Publication 1756-SG001P-EN-P - May 2011 33

ControlLogix Power Supplies

ControlLogix power supplies are used with the 1756 chassis to provide 12V 33V 5V and 24V DC power directly to the chassis backplane Select from these configurations

Standard power Redundant power ControlLogix-XT power

For detailed specifications see 1756 ControlLogix Power Supplies Specifications publication 1756-TD005

Standard Power Supplies

You mount a standard power supply directly on the left end of the chassis where it plugs directly into the backplane

ControlLogix-XT Power Supplies

The ControlLogix-XT power supplies support extreme temperature environments

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA72 ControlLogix standard AC 120V220V AC 85hellip265V AC Standard series A and series B

1756-PA75 120V220V AC 85hellip265V AC Standard series B

1756-PB72 ControlLogix standard DC 24V DC 18hellip32V DC Standard series A and series B

1756-PB75 24V DC 1832V DC Standard series B

1756-PC75 48V DC 30hellip60V DC Standard series B

1756-PH75 125V DC 90hellip143V DC Standard series B

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PAXT ControlLogix-XT AC power supply 85265V AC 120240V AC XT

1756-PBXT ControlLogix-XT DC power supply 24V DC 18hellip32V DC XT

34 Publication 1756-SG001P-EN-P - May 2011

Redundant Power Supplies

To build a redundant power supply system you need the following

Two redundant power supplies (both 1756-PA75R or 1756-PB75R) One 1756-PSCA2 chassis adapter module Two 1756-CPR2 cables to connect the power supplies to the

1756-PSCA2 chassis adapter module (091 m (3 ft) length) User-supplied annunciator wiring to connect the power supplies to the

input modules as needed

The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Accessories - Redundant Power Supplies

Visualization Products Visualization products together with Logix for control and NetLinx architecture for communication make up the Rockwell Automation Integrated Architecture strategy The visualization strategy combines Rockwell Automation expertise in Allen-Bradley electronic operator interface and industrialized personal computer hardware with Rockwell Software supervisory control software Current visualization products include the following

FactoryTalk View software PanelView Plus operator interface PanelView Plus CE operator interface Industrial computers and monitors

For more information see the Operator Interface catalog pages at httpwwwabcomenepubcatalogs1276221813761239781

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA75R ControlLogix redundant 120V220V AC 85hellip265V AC Standard series B

1756-PB75R 24V DC 192hellip32V DC Standard series B

Cat No Description Specifications

1756-PSCA2 Chassis adapter module Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Mounts directly to left side of 1756 chassis

1756-CPR2 Chassis adapter cable Connects redundant power supply to 1756-PCSA2 chassis adapter Length091 m (3 ft)

Publication 1756-SG001P-EN-P - May 2011 35

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU ltFEFF00560065007200770065006e00640065006e0020005300690065002000640069006500730065002000450069006e007300740065006c006c0075006e00670065006e0020007a0075006d002000450072007300740065006c006c0065006e00200076006f006e002000410064006f006200650020005000440046002d0044006f006b0075006d0065006e00740065006e002c00200076006f006e002000640065006e0065006e002000530069006500200068006f00630068007700650072007400690067006500200044007200750063006b006500200061007500660020004400650073006b0074006f0070002d0044007200750063006b00650072006e00200075006e0064002000500072006f006f0066002d00470065007200e400740065006e002000650072007a0065007500670065006e0020006d00f60063006800740065006e002e002000450072007300740065006c006c007400650020005000440046002d0044006f006b0075006d0065006e007400650020006b00f6006e006e0065006e0020006d006900740020004100630072006f00620061007400200075006e0064002000410064006f00620065002000520065006100640065007200200035002e00300020006f0064006500720020006800f600680065007200200067006500f600660066006e00650074002000770065007200640065006e002egt ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

Analog Motion Interface Modules

RSLogix 5000 Software1756-MxxSE Module

ControlLogix Controller

Three-phase Input Power

Line Interface Module

Integrated Axis Module

Motor Motor Feedback

Axis Modules

Slot Filler Module

Shunt Module

SERCOS Fiber-optic RingKinetix 6000 Multi-axis Servo Drive

Cat No Description Number of Axis

1756-M02AE Analog servo interface drives with quadrature feedback 2

1756-HYD02 Analog hydraulic servo interface drives LDT feedback 2

1756-M02AS Analog servo interface drives with SSI feedback 2

Publication 1756-SG001P-EN-P - May 2011 17

ControlLogix Communication Modules

Separate communication modules are available for different networks Install multiple communication modules into the ControlLogix backplane to bridge or route control and information data between different networks You can route a message through a maximum of four chassis (eight communication hops) You do not need a ControlLogix controller in the chassis

For detailed specifications see 1756 ControlLogix Network Specifications publication 1756-TD003

Application Network Page

Plant management (material handling) Configuration data collection and control on a single high-speed network Time-critical applications with no established schedule Inclusion of commercial technologies (such as video over IP) InternetIntranet connection Integrated CIP motion and safety

EtherNetIP network 19

High-speed transfer of time-critical data between controllers and IO devices Deterministic and repeatable data delivery Media redundancy Intrinsic safety Redundant controller systems

ControlNet network 20

Connections of low-level devices directly to plant floor controllers without interfacing them through IO modules

Data sent as needed More diagnostics for improved data collection and fault detection Less wiring and reduced start-up time than a traditional hard-wired system

DeviceNet network 21

Plant-wide and cell-level data sharing with program maintenance Data sent regularly Transfer of information between controllers

Data Highway Plus network 23

Connections between controllers and IO adapters Data sent regularly Distributed control so that each controller has its own IO and communicates with a

supervisory controller

Remote IO network 23

Fieldbus transmitters and actuators Closed-loop control Process automation

Foundation Fieldbus network 25

18 Publication 1756-SG001P-EN-P - May 2011

EtherNetIP Communication Modules

The Ethernet Industrial (EtherNetIP) network protocol is an open industrial-networking standard that supports both real-time IO messaging and message exchange The EtherNetIP network uses off-the-shelf Ethernet communication chips and physical media

Accessories - EtherNetIP Network

Cat No Description Media Communication Rate

CIP Motion Axes max

TCPIP Connections

Logix Connections

1756-EN2F EtherNetIP bridge fiber Fiber 100 Mbps 8 128 256

1756-EN2T EtherNetIP bridge copper Copper 10100 Mbps 8 128 256

1756-EN2TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 8 128 256

1756-EN3TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 255 128 256

1756-ENBT EtherNetIP bridge copper Copper 10100 Mbps mdash 64 128

1756-EWEB Ethernet web server module Copper 10100 Mbps mdash 64 128

1756-EN2TXT ControlLogix-XT extended temperature EtherNetIP bridge copper for extreme environments

Copper 10100 Mbps 8 128 256

Cat No Description Specifications

1585J-M8PBJM-x Ethernet RJ45 patchcordx = 2 (2 m) 5 (5 m) or 10 (10 m)

8-conductor Teal Riser PVC Cable (Flex Rated cable also available)

1585J-M8CC-H RJ45 insulation displacement connector (IDC) 01280325 mm2 (26hellip22 AWG) Cat 6 IDC no tool required

1585J-M8CC-C RJ45 crimp connector with boot qty = 50 pieces 01280205 mm2 (26hellip24 AWG Cat 5e requires crimp tool for assembly

1585A-Jcrimp Crimp tool mdash

9300-RADES Remote access dial-in kit 56 Kbps modem connection to devices on an Ethernet network includes pre-configured modem communication module DIN rail mounting hardware associated cables

Publication 1756-SG001P-EN-P - May 2011 19

Example Configuration - EtherNetIP Network

ControlNet Communication ModulesThe ControlNet network combines the functionality of an IO network and a peer-to-peer network providing high-speed performance The ControlNet network provides deterministic repeatable transfers of critical control data

FirewallRouter

Stratix Switch

Stratix Switch

Stratix Switch

Powermonitor 3000PowerFlex 70

Ethernet PLC-5

MicroLogix

Ethernet SLC 500

1756 IO

1794 IO

1761-NET-ENI

ControlNet

DeviceNet

1734 IO

RSLinxPanelView Plus

1769-L35E CompactLogix

Cat No Description Communication Rate

Logix Connections Number of Nodes

1756-CN2B ControlNet bridge standard media 5 Mbps 128(1) 99

1756-CN2RB ControlNet bridge redundant media 5 Mbps 128(1) 99

1756-CNB ControlNet bridge standard media 5 Mbps 64(2) 99

1756-CNBR ControlNet bridge redundant media 5 Mbps 64(2) 99

1756-CN2RXT ControlLogix-XT extended temperature ControlNet bridge redundant media

5 Mbps 128(1) 99

(1) 128 connections are available for standard use An additional three connections are reserved for redundant control

(2) Recommend using only 4048 Logix connections for IO

20 Publication 1756-SG001P-EN-P - May 2011

Example Configuration - ControlNet Network

Example Configuration - Redundant ControlNet Media

For information on ControlNet media see ControlNet Media System Components List AG-PA002

DeviceNet Communication Module

The DeviceNet network provides connections between simple industrial devices (such as sensors and actuators) and higher-level devices (such as controllers and computers)

1784-U2CNPanelView Plus

1788-CN2DN

DeviceNetPowerFlex 700SPLC-540CControlLogix

Redundant Media

ControlLogix1756-CNBR

ControlNet Node

ControlNet Node

Cat No Description Communication Rate Number of Nodes

1756-DNB DeviceNet bridge 125 Kbps (500 m max)250 Kbps (250 m max)500 Kbps (100 m max)

64

Publication 1756-SG001P-EN-P - May 2011 21

Example Configuration - DeviceNet Network

Accessories - DeviceNet Network

PLC-51771-SDN ControlLogix

1756-DNB

Ultra3000

PanelView Plus1784-U2DN

Ultra5000

IO

Motor starter

PowerFlex AC

Sensor Pushbuttons

LightsBar Code Scanner

Cat No Description

KwikLink Lite flat media KwikLink Lite flat media is a newer ODVA-approved solution for wiring DeviceNet networks Drop-lines for connecting nodes are added by using the KwikLink Lite two-piece connectors This cable system supports the intermixing of DeviceNet cable types (thin-round with flat) All of the KwikLink Lite connectors provide insulation displacement technology with reduced assembly time

KwikLink flat media The KwikLink flat media system provides a modular cabling method with its flat 4-wire cable and insulation displacement connectors (IDCs) The KwikLink system allows nodes to be added to the network without severing the trunkline Cutting or stripping of the trunkline is eliminated as is the need for predetermined cable lengths

Round media Round trunk cable is available in bulk spools or as pre-molded cordsets or patchcords in varying lengths A wide variety of rugged durable DeviceNet components is available for use in round trunk systems Stainless steel versions of round cable system components are also available Thick-trunk round media systems use thick cable for maximum DeviceNet trunk line length Round media thin-trunk systems use thin cable to reduce maximum trunk line distances with a more

compact and cost-effective installation for some applications Thin-cable outer jacket material is TPE for additional chemical resistance

22 Publication 1756-SG001P-EN-P - May 2011

Data Highway Plus and Remote IO Communication Modules

The Data Highway Plus network supports messaging between devices The remote IO link connects to remote IO chassis and other intelligent devices

The 1756-DHRIO module supports messaging between devices on DH+ networks The remote IO functionality enables the module to act as a scanner for transferring digital and block-transfer data to and from remote IO devices

The 1756-RIO module can act as a scanner or adapter on a remote IO network In addition to digital and block-transfer data the 1756-RIO module transfers analog and specialty data without message instructions

Cat No Description Communication Rate DH+ Connections RIO Connections Maximum Recommended Logix Connections

1756-DHRIO Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

1756-RIO Remote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

mdash Remote IO scanner or adapter32 physical racks (076) any combination of rack size and block transfers

10 scheduled IO

1756-DHRIOXT ControlLogix-XT extended temperature Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

Publication 1756-SG001P-EN-P - May 2011 23

Example Configuration - DH+ Network

Example Configuration - Remote IO Network

Accessories - DH+ and Remote IO Networks

PanelView Plus

PLC-5 1784-U2DHPRSLogix 5000

ControlLogix1756-DHRIO

SLC 504

PanelView PlusPLC-5

1791 IO1794 IO

1756-RIO as a Remote IO Adapter

1756-DHRIO as a Remote IO Scanner

Cat No Description Specifications

1770-CD Cable to connect communication module to DH+ network Belden 9463 twinaxial

9300-RADKIT Remote access dial-in kit 56 Kbps modem connection to devices on a DH+ network includes pre-configured modem communication module DIN rail mounting hardware associated cables

24 Publication 1756-SG001P-EN-P - May 2011

FOUNDATION Fieldbus Linking Devices

The FOUNDATION Fieldbus protocol is a network designed for distributed control of process applications

Example Configuration - Bridge to EtherNetIP Network

Cat No Description Communication Rate Number of H1 Ports

Devices per H1 Link

Devices per Linking Device

1757FFLD2 FOUNDATION Fieldbus bridge to an Ethernet network

FOUNDATION Fieldbus 3125 KbpsEtherNetIP 10100 Mbps

2 16(8hellip10 recommended)

32

1757-FFLD4 4 64

1757-FFLDC2 FOUNDATION Fieldbus bridge to a ControlNet network

FOUNDATION Fieldbus 3125 KbpsControlNet 5 Mbps

2 16(8hellip10 recommended)

32

1757-FFLDC4 4 64

FactoryTalk View SERSFieldbusRSLogix 5000

1757-FFLD4

H1(1)

H1(2)H1(3)H1(4)

HSEIP

Publication 1756-SG001P-EN-P - May 2011 25

Example Configuration - Bridge to ControlNet Network

Other Connectivity Options

ControlLogix RedundancyFactoryTalk View SERSFieldbusRSLogix 5000

ControlNet Redundant Media

1757-FFLDC2

FF H1

EtherNetIP

Option Consideration

USB connection The 1756-L7x controller has a USB port in place of the serial port If your application requires RS-232 functionality see the many Encompass partners at httpwwwrockwellautomationcomencompass

Serial connection The serial port on the 1756-L6x controller is compatible with RS-232 serial communication The serial port supports the DF1 protocol to communicate with other devices on the serial linkTo use Logix5000 controllers on Modbus you connect through the serial port and execute a specific ladder logic routine The controller project is available with RSLogix 5000 Enterprise programming software For more information see Using Logix5000 Controllers as Masters or Slaves on Modbus Application Solution publication CIG-AP129

DH-485 network The controller serial port is compatible with DH-485 communication The DH-485 connection does support remote programming and monitoring via RSLogix 5000 softwareOr add a DH-485 communication bridge module (cat no 1756-DH485)

SynchLink network The SynchLink communication module (1756-SYNCH) provides time synchronization and data broadcasting capabilities for distributed motion and coordinated drive control The module connects a ControlLogix chassis to a SynchLink fiber-optic communication link

26 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Controllers The ControlLogix controller provides a scalable controller solution that is capable of addressing a large amount of IO points

The controller can be placed into any slot of a ControlLogix chassis and multiple controllers can be installed in the same chassis Multiple controllers in the same chassis communicate with each other over the backplane (just as controllers can communicate over networks) but operate independently

ControlLogix controllers can monitor and control IO across the ControlLogix backplane as well as over IO links ControlLogix controllers can communicate over EtherNetIP ControlNet DeviceNet DH+ Remote IO and RS-232-C (DF1DH-485 protocol) networks and many third party process and device networks To provide communication for a ControlLogix controller install the appropriate communication interface module into the chassis

For detailed specifications see 1756 ControlLogix Controllers Specifications publication 1756-TD001

Cat No Description User Memory

1756-L72 ControlLogix controller 1 built-in USB port 4 MB

1756-L73 8 MB

1756-L74 16 MB

1756-L75 32 MB

1756-L61 ControlLogix controller 1 built-in RS-232 port 2 MB

1756-L62 4 MB

1756-L63 8 MB

1756-L64 16 MB

1756-L65 32 MB

1756-L61S GuardLogix safety controller 2 MB standard1 MB safety

1756-L62S 4 MB standard1 MB safety

1756-L63S 8 MB standard375 MB safety

1756-LSP GuardLogix safety partner (one is required for each GuardLogix controller) mdash

1756-L63XT ControlLogix-XT controller extreme environment 8 MB

IMPORTANT Scan time for a project loaded in a 1756-L64 or 1756-L65 controller may be slower than for the same project loaded in one of the other 1756-L6x controllers See the Logix5000 Controllers Instruction Execution Time and Memory Use Reference Manual publication 1756-RM087 for instruction execution times

Publication 1756-SG001P-EN-P - May 2011 27

Standard ControlLogix Controllers

The ControlLogix controller is part of the Logix5000 family of controllers A ControlLogix system includes the following

The ControlLogix controller available in different combinations of user memory

RSLogix 5000 programming software 1756 ControlLogix IO modules that reside in a 1756 chassis Separate communication modules for network communication

Features - Standard ControlLogix Controllers

Feature 1756-L61 1756-L62 1756-L63 1756-L64 1756-L65

1756-L72 1756-L73 1756-L74 1756-L75

Controller tasks 32 tasks 100 programstask Event tasks all event triggers

Built-in communication ports 1 port RS-232 serial 1 port USB

Communication options EtherNetIP ControlNet DeviceNet Data Highway Plus Remote IO SynchLink Third-party process and device networks

Built-in port Serial USB

Controller connections supported max 250 500

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Full support

Integrated motion EtherNetIP connection SERCOS interface Analog options (encoder input LDT input SSI input)

Programming languages Relay ladder Structured text Function block SFC

28 Publication 1756-SG001P-EN-P - May 2011

GuardLogix Controllers

A GuardLogix controller is a ControlLogix controller that also provides safety control The GuardLogix system is a dual controller solutionmdashyou must use a 1756-L6xS primary controller and a 1756-LSP safety partner to achieve SIL 3CAT 4

During development safety and standard have the same rules multiple programmers online editing and forcing are all allowed Once the project is tested and ready for final validation you set the Safety Task to a SIL 3 integrity level which is then enforced by the GuardLogix controller When safety memory is locked and protected the safety logic cant be modified and all safety functions operate with SIL 3 integrity On the standard side of the GuardLogix controller all functions operate like a regular Logix controller

Use Guard IO modules for field device connectivity on Ethernet or DeviceNet networks and for safety interlocking between GuardLogix controllers use Ethernet or ControlNet networks Multiple GuardLogix controllers can share safety data for zone to zone interlocking or a single GuardLogix controller can use remote distributed safety IO between different cellsareas

In addition to the standard features of a ControlLogix controller the GuardLogix controller has these safety-related features

Application Description

SIL 1 2 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508 and applications up to and including PLeCat4 according to ISO 13849-1 For more information see GuardLogix Controllers Systems Safety Reference Manual publication 1756-RM093 GuardLogix Controllers User Manual publication 1756-UM020 GuardLogix Safety Application Instruction Set Reference Manual publication 1756-RM095

Features - GuardLogix Controllers

Feature 1756-L61S 1756-L62S 1756-L63S 1756-LSP

Safety communication options Standard and safety EtherNetIP ControlNet DeviceNet

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Not supported

Programming languages Relay ladder

Publication 1756-SG001P-EN-P - May 2011 29

ControlLogix-XT Controllers

The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh corrosive environments

When used with FLEX IO-XT products the ControlLogix-XT system can withstand temperatures range from -2070 C (-4158 F)

When used independently the ControlLogix-XT system can withstand temperature ranges from -2570 C (-13158 F)

Redundant ControlLogix Controllers

The ControlLogix controller supports controller redundancy In a redundant controller system you need these components

Two 1756 chassis each with the following the same ndash Number of slots

ndash Modules in the same slots

ndash Redundancy firmware revisions in each module

ndash Two additional ControlNet nodes outside the redundant chassis pair

You need one of these redundancy modules

One 1756-RM module per chassis that supports the followingndash Two 1756-L61 1756-L62 1761-L63 controllers or one 1756-L64

controller

ndash Maximum of seven communication modules which can be 1756-CN2 series B 1756-CN2R series B and 1756-EN2T modules

ndash One 1756-RMCx cable

One 1757-SRM module per chassis that supports the followingndash One 1756-L61 1756-L62 1756-L63 1756-L64 controller

ndash Maximum of seven communication modules which can be 1756-CNB series D or E 1756-CNBR series D or E 1756-ENBT and 1756-EWEB modules

ndash One 1757-SRCx cable

30 Publication 1756-SG001P-EN-P - May 2011

Accessories - Controllers

Memory Cards

Memory cards offer nonvolatile memory to permanently store a user program and tag data on a controller The 1756-L7x ControlLogix controller comes with 1784-SD1 Secure Digital (SD) card already installed The 1756-L6x controllers support optional CompactFlash cards that you purchase separately The memory card installs in a socket on the controller Through RSLogix 5000 software you can manually trigger the controller to save to or load from nonvolatile memory or configure the controller to load from nonvolatile memory on powerup

The GuardLogix controller does not support user program storage or retrieval by using a CompactFlash card

1756 Energy Storage Modules

Instead of a battery the 1756-L7x controller ships with a 1756-ESMCAP energy storage module (ESM) already installed

Attribute 1784-CF64 1784-CF128 1784-SD1 1784-SD2

Memory 64 MB 128 MB 1 GB 2 GB

Supported controllers 1756-L6x 1756-L7x

Weight approx 142 g (05 oz) 176 g (0062 oz)

Cat No Description

1756-ESMCAP Capacitor-based energy-storage module Comes with the controller

1756-EMNSE ESM without WallClockTime backup power Additionally you can use this ESM with a 1756-L73 (8 MB) or smaller memory-sized controller only

Use this ESM if your application requires that the installed ESM deplete its residual energy to 40 microJoule or less before transporting it into or out of your application

1756-ESMNRM Energy-storage module that secures the controller by preventing the USB connection and SD card useThis ESM provides your application an enhanced degree of security

Publication 1756-SG001P-EN-P - May 2011 31

1756 ControlLogix Batteries

Each 1756-L6x controller ships with a battery With a memory card installed the controller can be used without a battery If you do not use a battery current tag data will be at the state it was when the memory card was saved

ControlLogix Chassis The ControlLogix system is a modular system that requires a 1756 IO chassis Place any module into any slot The backplane provides a high-speed communication path between modules

All of the chassis are designed for horizontal-only back-panel mounting The chassis are available in these configurations

Standard chassis ControlLogix-XT chassis

For detailed specifications see 1756 ControlLogix Chassis Specifications Specifications publication 1756-TD006

Features - Chassis

Slot guides and snap-in retention for easy and secure module fit for any type of 1756 module

Direct mounting accommodates any 1756 power supply

Attribute 1756-BA1 1756-BA2 1756-BATM(1) 1756-BATA

Description Lithium battery (059 g) Lithium battery (059 g) Externally mounted battery assembly

Replacement lithium battery for 1756-BATM (5 g max lithium per each D cell contains 2 D cells)

ControlLogix controllers 1756-L61 1756-L62 1756-L63 series A

1756-L61 1756-L62 1756-L63 series B1756-L64 1756-L65

1756-L61 1756-L62 1756-L63 series A

1756-BATM battery module

GuardLogix controllers mdash 1756-L61S 1756-L62S 1756-L63S

mdash mdash

ControlLogix-XT controllers

mdash 1756-L63XT mdash mdash

(1) The 1756-BATM externally mounted battery assembly is highly recommended for use with all series A 1756-L6x controllers and provides longer battery life than the 1756-BA1 battery The 1756-BATM includes one 1756-BATA lithium battery assembly and a 1 m (328 ft) cable to connect housing to controller

32 Publication 1756-SG001P-EN-P - May 2011

Standard Chassis

The chassis backplane provides a high-speed communication path between modules and distributes power to each of the modules within the chassis

ControlLogix-XT Chassis

The ControlLogix-XT chassis support extreme temperature environments

Accessories - Chassis

Use a slot filler module to fill empty slots

Cat No Description Slots

1756-A4 ControlLogix standard chassis 4

1756-A7 7

1756-A10 10

1756-A13 13

1756-A17 17

Cat No Description Slots Temperature Range

1756-A4LXT ControlLogix-XT chassis 4 -2560 degC (-13140 degF)

1756-A5XT 5 -2570 degC (-13158 degF)

1756-A7LXT 7 -2560 degC (-13140 degF)

Cat No Description

1756-N2 Slot filler module for empty slots in standard ControlLogix chassis

1756-N2XT Slot filler module for empty slots in ControlLogix-XT chassis

Publication 1756-SG001P-EN-P - May 2011 33

ControlLogix Power Supplies

ControlLogix power supplies are used with the 1756 chassis to provide 12V 33V 5V and 24V DC power directly to the chassis backplane Select from these configurations

Standard power Redundant power ControlLogix-XT power

For detailed specifications see 1756 ControlLogix Power Supplies Specifications publication 1756-TD005

Standard Power Supplies

You mount a standard power supply directly on the left end of the chassis where it plugs directly into the backplane

ControlLogix-XT Power Supplies

The ControlLogix-XT power supplies support extreme temperature environments

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA72 ControlLogix standard AC 120V220V AC 85hellip265V AC Standard series A and series B

1756-PA75 120V220V AC 85hellip265V AC Standard series B

1756-PB72 ControlLogix standard DC 24V DC 18hellip32V DC Standard series A and series B

1756-PB75 24V DC 1832V DC Standard series B

1756-PC75 48V DC 30hellip60V DC Standard series B

1756-PH75 125V DC 90hellip143V DC Standard series B

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PAXT ControlLogix-XT AC power supply 85265V AC 120240V AC XT

1756-PBXT ControlLogix-XT DC power supply 24V DC 18hellip32V DC XT

34 Publication 1756-SG001P-EN-P - May 2011

Redundant Power Supplies

To build a redundant power supply system you need the following

Two redundant power supplies (both 1756-PA75R or 1756-PB75R) One 1756-PSCA2 chassis adapter module Two 1756-CPR2 cables to connect the power supplies to the

1756-PSCA2 chassis adapter module (091 m (3 ft) length) User-supplied annunciator wiring to connect the power supplies to the

input modules as needed

The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Accessories - Redundant Power Supplies

Visualization Products Visualization products together with Logix for control and NetLinx architecture for communication make up the Rockwell Automation Integrated Architecture strategy The visualization strategy combines Rockwell Automation expertise in Allen-Bradley electronic operator interface and industrialized personal computer hardware with Rockwell Software supervisory control software Current visualization products include the following

FactoryTalk View software PanelView Plus operator interface PanelView Plus CE operator interface Industrial computers and monitors

For more information see the Operator Interface catalog pages at httpwwwabcomenepubcatalogs1276221813761239781

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA75R ControlLogix redundant 120V220V AC 85hellip265V AC Standard series B

1756-PB75R 24V DC 192hellip32V DC Standard series B

Cat No Description Specifications

1756-PSCA2 Chassis adapter module Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Mounts directly to left side of 1756 chassis

1756-CPR2 Chassis adapter cable Connects redundant power supply to 1756-PCSA2 chassis adapter Length091 m (3 ft)

Publication 1756-SG001P-EN-P - May 2011 35

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA ltFEFF005500740069006c006900730065007a00200063006500730020006f007000740069006f006e00730020006100660069006e00200064006500200063007200e900650072002000640065007300200064006f00630075006d0065006e00740073002000410064006f00620065002000500044004600200070006f007500720020006400650073002000e90070007200650075007600650073002000650074002000640065007300200069006d007000720065007300730069006f006e00730020006400650020006800610075007400650020007100750061006c0069007400e90020007300750072002000640065007300200069006d007000720069006d0061006e0074006500730020006400650020006200750072006500610075002e0020004c0065007300200064006f00630075006d0065006e00740073002000500044004600200063007200e900e90073002000700065007500760065006e0074002000ea0074007200650020006f007500760065007200740073002000640061006e00730020004100630072006f006200610074002c002000610069006e00730069002000710075002700410064006f00620065002000520065006100640065007200200035002e0030002000650074002000760065007200730069006f006e007300200075006c007400e90072006900650075007200650073002egt ITA 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 JPN ltFEFF9ad854c18cea51fa529b7528002000410064006f0062006500200050004400460020658766f8306e4f5c6210306b4f7f75283057307e30593002537052376642306e753b8cea3092670059279650306b4fdd306430533068304c3067304d307e3059300230c730b930af30c830c330d730d730ea30f330bf3067306e53705237307e305f306f30d730eb30fc30d57528306b9069305730663044307e305930023053306e8a2d5b9a30674f5c62103055308c305f0020005000440046002030d530a130a430eb306f3001004100630072006f0062006100740020304a30883073002000410064006f00620065002000520065006100640065007200200035002e003000204ee5964d3067958b304f30533068304c3067304d307e30593002gt KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO ltFEFF004b00e40079007400e40020006e00e40069007400e4002000610073006500740075006b007300690061002c0020006b0075006e0020006c0075006f0074002000410064006f0062006500200050004400460020002d0064006f006b0075006d0065006e007400740065006a00610020006c0061006100640075006b006100730074006100200074007900f6007000f60079007400e400740075006c006f0073007400750073007400610020006a00610020007600650064006f007300740075007300740061002000760061007200740065006e002e00200020004c0075006f0064007500740020005000440046002d0064006f006b0075006d0065006e00740069007400200076006f0069006400610061006e0020006100760061007400610020004100630072006f0062006100740069006c006c00610020006a0061002000410064006f00620065002000520065006100640065007200200035002e0030003a006c006c00610020006a006100200075007500640065006d006d0069006c006c0061002egt SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

ControlLogix Communication Modules

Separate communication modules are available for different networks Install multiple communication modules into the ControlLogix backplane to bridge or route control and information data between different networks You can route a message through a maximum of four chassis (eight communication hops) You do not need a ControlLogix controller in the chassis

For detailed specifications see 1756 ControlLogix Network Specifications publication 1756-TD003

Application Network Page

Plant management (material handling) Configuration data collection and control on a single high-speed network Time-critical applications with no established schedule Inclusion of commercial technologies (such as video over IP) InternetIntranet connection Integrated CIP motion and safety

EtherNetIP network 19

High-speed transfer of time-critical data between controllers and IO devices Deterministic and repeatable data delivery Media redundancy Intrinsic safety Redundant controller systems

ControlNet network 20

Connections of low-level devices directly to plant floor controllers without interfacing them through IO modules

Data sent as needed More diagnostics for improved data collection and fault detection Less wiring and reduced start-up time than a traditional hard-wired system

DeviceNet network 21

Plant-wide and cell-level data sharing with program maintenance Data sent regularly Transfer of information between controllers

Data Highway Plus network 23

Connections between controllers and IO adapters Data sent regularly Distributed control so that each controller has its own IO and communicates with a

supervisory controller

Remote IO network 23

Fieldbus transmitters and actuators Closed-loop control Process automation

Foundation Fieldbus network 25

18 Publication 1756-SG001P-EN-P - May 2011

EtherNetIP Communication Modules

The Ethernet Industrial (EtherNetIP) network protocol is an open industrial-networking standard that supports both real-time IO messaging and message exchange The EtherNetIP network uses off-the-shelf Ethernet communication chips and physical media

Accessories - EtherNetIP Network

Cat No Description Media Communication Rate

CIP Motion Axes max

TCPIP Connections

Logix Connections

1756-EN2F EtherNetIP bridge fiber Fiber 100 Mbps 8 128 256

1756-EN2T EtherNetIP bridge copper Copper 10100 Mbps 8 128 256

1756-EN2TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 8 128 256

1756-EN3TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 255 128 256

1756-ENBT EtherNetIP bridge copper Copper 10100 Mbps mdash 64 128

1756-EWEB Ethernet web server module Copper 10100 Mbps mdash 64 128

1756-EN2TXT ControlLogix-XT extended temperature EtherNetIP bridge copper for extreme environments

Copper 10100 Mbps 8 128 256

Cat No Description Specifications

1585J-M8PBJM-x Ethernet RJ45 patchcordx = 2 (2 m) 5 (5 m) or 10 (10 m)

8-conductor Teal Riser PVC Cable (Flex Rated cable also available)

1585J-M8CC-H RJ45 insulation displacement connector (IDC) 01280325 mm2 (26hellip22 AWG) Cat 6 IDC no tool required

1585J-M8CC-C RJ45 crimp connector with boot qty = 50 pieces 01280205 mm2 (26hellip24 AWG Cat 5e requires crimp tool for assembly

1585A-Jcrimp Crimp tool mdash

9300-RADES Remote access dial-in kit 56 Kbps modem connection to devices on an Ethernet network includes pre-configured modem communication module DIN rail mounting hardware associated cables

Publication 1756-SG001P-EN-P - May 2011 19

Example Configuration - EtherNetIP Network

ControlNet Communication ModulesThe ControlNet network combines the functionality of an IO network and a peer-to-peer network providing high-speed performance The ControlNet network provides deterministic repeatable transfers of critical control data

FirewallRouter

Stratix Switch

Stratix Switch

Stratix Switch

Powermonitor 3000PowerFlex 70

Ethernet PLC-5

MicroLogix

Ethernet SLC 500

1756 IO

1794 IO

1761-NET-ENI

ControlNet

DeviceNet

1734 IO

RSLinxPanelView Plus

1769-L35E CompactLogix

Cat No Description Communication Rate

Logix Connections Number of Nodes

1756-CN2B ControlNet bridge standard media 5 Mbps 128(1) 99

1756-CN2RB ControlNet bridge redundant media 5 Mbps 128(1) 99

1756-CNB ControlNet bridge standard media 5 Mbps 64(2) 99

1756-CNBR ControlNet bridge redundant media 5 Mbps 64(2) 99

1756-CN2RXT ControlLogix-XT extended temperature ControlNet bridge redundant media

5 Mbps 128(1) 99

(1) 128 connections are available for standard use An additional three connections are reserved for redundant control

(2) Recommend using only 4048 Logix connections for IO

20 Publication 1756-SG001P-EN-P - May 2011

Example Configuration - ControlNet Network

Example Configuration - Redundant ControlNet Media

For information on ControlNet media see ControlNet Media System Components List AG-PA002

DeviceNet Communication Module

The DeviceNet network provides connections between simple industrial devices (such as sensors and actuators) and higher-level devices (such as controllers and computers)

1784-U2CNPanelView Plus

1788-CN2DN

DeviceNetPowerFlex 700SPLC-540CControlLogix

Redundant Media

ControlLogix1756-CNBR

ControlNet Node

ControlNet Node

Cat No Description Communication Rate Number of Nodes

1756-DNB DeviceNet bridge 125 Kbps (500 m max)250 Kbps (250 m max)500 Kbps (100 m max)

64

Publication 1756-SG001P-EN-P - May 2011 21

Example Configuration - DeviceNet Network

Accessories - DeviceNet Network

PLC-51771-SDN ControlLogix

1756-DNB

Ultra3000

PanelView Plus1784-U2DN

Ultra5000

IO

Motor starter

PowerFlex AC

Sensor Pushbuttons

LightsBar Code Scanner

Cat No Description

KwikLink Lite flat media KwikLink Lite flat media is a newer ODVA-approved solution for wiring DeviceNet networks Drop-lines for connecting nodes are added by using the KwikLink Lite two-piece connectors This cable system supports the intermixing of DeviceNet cable types (thin-round with flat) All of the KwikLink Lite connectors provide insulation displacement technology with reduced assembly time

KwikLink flat media The KwikLink flat media system provides a modular cabling method with its flat 4-wire cable and insulation displacement connectors (IDCs) The KwikLink system allows nodes to be added to the network without severing the trunkline Cutting or stripping of the trunkline is eliminated as is the need for predetermined cable lengths

Round media Round trunk cable is available in bulk spools or as pre-molded cordsets or patchcords in varying lengths A wide variety of rugged durable DeviceNet components is available for use in round trunk systems Stainless steel versions of round cable system components are also available Thick-trunk round media systems use thick cable for maximum DeviceNet trunk line length Round media thin-trunk systems use thin cable to reduce maximum trunk line distances with a more

compact and cost-effective installation for some applications Thin-cable outer jacket material is TPE for additional chemical resistance

22 Publication 1756-SG001P-EN-P - May 2011

Data Highway Plus and Remote IO Communication Modules

The Data Highway Plus network supports messaging between devices The remote IO link connects to remote IO chassis and other intelligent devices

The 1756-DHRIO module supports messaging between devices on DH+ networks The remote IO functionality enables the module to act as a scanner for transferring digital and block-transfer data to and from remote IO devices

The 1756-RIO module can act as a scanner or adapter on a remote IO network In addition to digital and block-transfer data the 1756-RIO module transfers analog and specialty data without message instructions

Cat No Description Communication Rate DH+ Connections RIO Connections Maximum Recommended Logix Connections

1756-DHRIO Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

1756-RIO Remote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

mdash Remote IO scanner or adapter32 physical racks (076) any combination of rack size and block transfers

10 scheduled IO

1756-DHRIOXT ControlLogix-XT extended temperature Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

Publication 1756-SG001P-EN-P - May 2011 23

Example Configuration - DH+ Network

Example Configuration - Remote IO Network

Accessories - DH+ and Remote IO Networks

PanelView Plus

PLC-5 1784-U2DHPRSLogix 5000

ControlLogix1756-DHRIO

SLC 504

PanelView PlusPLC-5

1791 IO1794 IO

1756-RIO as a Remote IO Adapter

1756-DHRIO as a Remote IO Scanner

Cat No Description Specifications

1770-CD Cable to connect communication module to DH+ network Belden 9463 twinaxial

9300-RADKIT Remote access dial-in kit 56 Kbps modem connection to devices on a DH+ network includes pre-configured modem communication module DIN rail mounting hardware associated cables

24 Publication 1756-SG001P-EN-P - May 2011

FOUNDATION Fieldbus Linking Devices

The FOUNDATION Fieldbus protocol is a network designed for distributed control of process applications

Example Configuration - Bridge to EtherNetIP Network

Cat No Description Communication Rate Number of H1 Ports

Devices per H1 Link

Devices per Linking Device

1757FFLD2 FOUNDATION Fieldbus bridge to an Ethernet network

FOUNDATION Fieldbus 3125 KbpsEtherNetIP 10100 Mbps

2 16(8hellip10 recommended)

32

1757-FFLD4 4 64

1757-FFLDC2 FOUNDATION Fieldbus bridge to a ControlNet network

FOUNDATION Fieldbus 3125 KbpsControlNet 5 Mbps

2 16(8hellip10 recommended)

32

1757-FFLDC4 4 64

FactoryTalk View SERSFieldbusRSLogix 5000

1757-FFLD4

H1(1)

H1(2)H1(3)H1(4)

HSEIP

Publication 1756-SG001P-EN-P - May 2011 25

Example Configuration - Bridge to ControlNet Network

Other Connectivity Options

ControlLogix RedundancyFactoryTalk View SERSFieldbusRSLogix 5000

ControlNet Redundant Media

1757-FFLDC2

FF H1

EtherNetIP

Option Consideration

USB connection The 1756-L7x controller has a USB port in place of the serial port If your application requires RS-232 functionality see the many Encompass partners at httpwwwrockwellautomationcomencompass

Serial connection The serial port on the 1756-L6x controller is compatible with RS-232 serial communication The serial port supports the DF1 protocol to communicate with other devices on the serial linkTo use Logix5000 controllers on Modbus you connect through the serial port and execute a specific ladder logic routine The controller project is available with RSLogix 5000 Enterprise programming software For more information see Using Logix5000 Controllers as Masters or Slaves on Modbus Application Solution publication CIG-AP129

DH-485 network The controller serial port is compatible with DH-485 communication The DH-485 connection does support remote programming and monitoring via RSLogix 5000 softwareOr add a DH-485 communication bridge module (cat no 1756-DH485)

SynchLink network The SynchLink communication module (1756-SYNCH) provides time synchronization and data broadcasting capabilities for distributed motion and coordinated drive control The module connects a ControlLogix chassis to a SynchLink fiber-optic communication link

26 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Controllers The ControlLogix controller provides a scalable controller solution that is capable of addressing a large amount of IO points

The controller can be placed into any slot of a ControlLogix chassis and multiple controllers can be installed in the same chassis Multiple controllers in the same chassis communicate with each other over the backplane (just as controllers can communicate over networks) but operate independently

ControlLogix controllers can monitor and control IO across the ControlLogix backplane as well as over IO links ControlLogix controllers can communicate over EtherNetIP ControlNet DeviceNet DH+ Remote IO and RS-232-C (DF1DH-485 protocol) networks and many third party process and device networks To provide communication for a ControlLogix controller install the appropriate communication interface module into the chassis

For detailed specifications see 1756 ControlLogix Controllers Specifications publication 1756-TD001

Cat No Description User Memory

1756-L72 ControlLogix controller 1 built-in USB port 4 MB

1756-L73 8 MB

1756-L74 16 MB

1756-L75 32 MB

1756-L61 ControlLogix controller 1 built-in RS-232 port 2 MB

1756-L62 4 MB

1756-L63 8 MB

1756-L64 16 MB

1756-L65 32 MB

1756-L61S GuardLogix safety controller 2 MB standard1 MB safety

1756-L62S 4 MB standard1 MB safety

1756-L63S 8 MB standard375 MB safety

1756-LSP GuardLogix safety partner (one is required for each GuardLogix controller) mdash

1756-L63XT ControlLogix-XT controller extreme environment 8 MB

IMPORTANT Scan time for a project loaded in a 1756-L64 or 1756-L65 controller may be slower than for the same project loaded in one of the other 1756-L6x controllers See the Logix5000 Controllers Instruction Execution Time and Memory Use Reference Manual publication 1756-RM087 for instruction execution times

Publication 1756-SG001P-EN-P - May 2011 27

Standard ControlLogix Controllers

The ControlLogix controller is part of the Logix5000 family of controllers A ControlLogix system includes the following

The ControlLogix controller available in different combinations of user memory

RSLogix 5000 programming software 1756 ControlLogix IO modules that reside in a 1756 chassis Separate communication modules for network communication

Features - Standard ControlLogix Controllers

Feature 1756-L61 1756-L62 1756-L63 1756-L64 1756-L65

1756-L72 1756-L73 1756-L74 1756-L75

Controller tasks 32 tasks 100 programstask Event tasks all event triggers

Built-in communication ports 1 port RS-232 serial 1 port USB

Communication options EtherNetIP ControlNet DeviceNet Data Highway Plus Remote IO SynchLink Third-party process and device networks

Built-in port Serial USB

Controller connections supported max 250 500

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Full support

Integrated motion EtherNetIP connection SERCOS interface Analog options (encoder input LDT input SSI input)

Programming languages Relay ladder Structured text Function block SFC

28 Publication 1756-SG001P-EN-P - May 2011

GuardLogix Controllers

A GuardLogix controller is a ControlLogix controller that also provides safety control The GuardLogix system is a dual controller solutionmdashyou must use a 1756-L6xS primary controller and a 1756-LSP safety partner to achieve SIL 3CAT 4

During development safety and standard have the same rules multiple programmers online editing and forcing are all allowed Once the project is tested and ready for final validation you set the Safety Task to a SIL 3 integrity level which is then enforced by the GuardLogix controller When safety memory is locked and protected the safety logic cant be modified and all safety functions operate with SIL 3 integrity On the standard side of the GuardLogix controller all functions operate like a regular Logix controller

Use Guard IO modules for field device connectivity on Ethernet or DeviceNet networks and for safety interlocking between GuardLogix controllers use Ethernet or ControlNet networks Multiple GuardLogix controllers can share safety data for zone to zone interlocking or a single GuardLogix controller can use remote distributed safety IO between different cellsareas

In addition to the standard features of a ControlLogix controller the GuardLogix controller has these safety-related features

Application Description

SIL 1 2 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508 and applications up to and including PLeCat4 according to ISO 13849-1 For more information see GuardLogix Controllers Systems Safety Reference Manual publication 1756-RM093 GuardLogix Controllers User Manual publication 1756-UM020 GuardLogix Safety Application Instruction Set Reference Manual publication 1756-RM095

Features - GuardLogix Controllers

Feature 1756-L61S 1756-L62S 1756-L63S 1756-LSP

Safety communication options Standard and safety EtherNetIP ControlNet DeviceNet

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Not supported

Programming languages Relay ladder

Publication 1756-SG001P-EN-P - May 2011 29

ControlLogix-XT Controllers

The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh corrosive environments

When used with FLEX IO-XT products the ControlLogix-XT system can withstand temperatures range from -2070 C (-4158 F)

When used independently the ControlLogix-XT system can withstand temperature ranges from -2570 C (-13158 F)

Redundant ControlLogix Controllers

The ControlLogix controller supports controller redundancy In a redundant controller system you need these components

Two 1756 chassis each with the following the same ndash Number of slots

ndash Modules in the same slots

ndash Redundancy firmware revisions in each module

ndash Two additional ControlNet nodes outside the redundant chassis pair

You need one of these redundancy modules

One 1756-RM module per chassis that supports the followingndash Two 1756-L61 1756-L62 1761-L63 controllers or one 1756-L64

controller

ndash Maximum of seven communication modules which can be 1756-CN2 series B 1756-CN2R series B and 1756-EN2T modules

ndash One 1756-RMCx cable

One 1757-SRM module per chassis that supports the followingndash One 1756-L61 1756-L62 1756-L63 1756-L64 controller

ndash Maximum of seven communication modules which can be 1756-CNB series D or E 1756-CNBR series D or E 1756-ENBT and 1756-EWEB modules

ndash One 1757-SRCx cable

30 Publication 1756-SG001P-EN-P - May 2011

Accessories - Controllers

Memory Cards

Memory cards offer nonvolatile memory to permanently store a user program and tag data on a controller The 1756-L7x ControlLogix controller comes with 1784-SD1 Secure Digital (SD) card already installed The 1756-L6x controllers support optional CompactFlash cards that you purchase separately The memory card installs in a socket on the controller Through RSLogix 5000 software you can manually trigger the controller to save to or load from nonvolatile memory or configure the controller to load from nonvolatile memory on powerup

The GuardLogix controller does not support user program storage or retrieval by using a CompactFlash card

1756 Energy Storage Modules

Instead of a battery the 1756-L7x controller ships with a 1756-ESMCAP energy storage module (ESM) already installed

Attribute 1784-CF64 1784-CF128 1784-SD1 1784-SD2

Memory 64 MB 128 MB 1 GB 2 GB

Supported controllers 1756-L6x 1756-L7x

Weight approx 142 g (05 oz) 176 g (0062 oz)

Cat No Description

1756-ESMCAP Capacitor-based energy-storage module Comes with the controller

1756-EMNSE ESM without WallClockTime backup power Additionally you can use this ESM with a 1756-L73 (8 MB) or smaller memory-sized controller only

Use this ESM if your application requires that the installed ESM deplete its residual energy to 40 microJoule or less before transporting it into or out of your application

1756-ESMNRM Energy-storage module that secures the controller by preventing the USB connection and SD card useThis ESM provides your application an enhanced degree of security

Publication 1756-SG001P-EN-P - May 2011 31

1756 ControlLogix Batteries

Each 1756-L6x controller ships with a battery With a memory card installed the controller can be used without a battery If you do not use a battery current tag data will be at the state it was when the memory card was saved

ControlLogix Chassis The ControlLogix system is a modular system that requires a 1756 IO chassis Place any module into any slot The backplane provides a high-speed communication path between modules

All of the chassis are designed for horizontal-only back-panel mounting The chassis are available in these configurations

Standard chassis ControlLogix-XT chassis

For detailed specifications see 1756 ControlLogix Chassis Specifications Specifications publication 1756-TD006

Features - Chassis

Slot guides and snap-in retention for easy and secure module fit for any type of 1756 module

Direct mounting accommodates any 1756 power supply

Attribute 1756-BA1 1756-BA2 1756-BATM(1) 1756-BATA

Description Lithium battery (059 g) Lithium battery (059 g) Externally mounted battery assembly

Replacement lithium battery for 1756-BATM (5 g max lithium per each D cell contains 2 D cells)

ControlLogix controllers 1756-L61 1756-L62 1756-L63 series A

1756-L61 1756-L62 1756-L63 series B1756-L64 1756-L65

1756-L61 1756-L62 1756-L63 series A

1756-BATM battery module

GuardLogix controllers mdash 1756-L61S 1756-L62S 1756-L63S

mdash mdash

ControlLogix-XT controllers

mdash 1756-L63XT mdash mdash

(1) The 1756-BATM externally mounted battery assembly is highly recommended for use with all series A 1756-L6x controllers and provides longer battery life than the 1756-BA1 battery The 1756-BATM includes one 1756-BATA lithium battery assembly and a 1 m (328 ft) cable to connect housing to controller

32 Publication 1756-SG001P-EN-P - May 2011

Standard Chassis

The chassis backplane provides a high-speed communication path between modules and distributes power to each of the modules within the chassis

ControlLogix-XT Chassis

The ControlLogix-XT chassis support extreme temperature environments

Accessories - Chassis

Use a slot filler module to fill empty slots

Cat No Description Slots

1756-A4 ControlLogix standard chassis 4

1756-A7 7

1756-A10 10

1756-A13 13

1756-A17 17

Cat No Description Slots Temperature Range

1756-A4LXT ControlLogix-XT chassis 4 -2560 degC (-13140 degF)

1756-A5XT 5 -2570 degC (-13158 degF)

1756-A7LXT 7 -2560 degC (-13140 degF)

Cat No Description

1756-N2 Slot filler module for empty slots in standard ControlLogix chassis

1756-N2XT Slot filler module for empty slots in ControlLogix-XT chassis

Publication 1756-SG001P-EN-P - May 2011 33

ControlLogix Power Supplies

ControlLogix power supplies are used with the 1756 chassis to provide 12V 33V 5V and 24V DC power directly to the chassis backplane Select from these configurations

Standard power Redundant power ControlLogix-XT power

For detailed specifications see 1756 ControlLogix Power Supplies Specifications publication 1756-TD005

Standard Power Supplies

You mount a standard power supply directly on the left end of the chassis where it plugs directly into the backplane

ControlLogix-XT Power Supplies

The ControlLogix-XT power supplies support extreme temperature environments

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA72 ControlLogix standard AC 120V220V AC 85hellip265V AC Standard series A and series B

1756-PA75 120V220V AC 85hellip265V AC Standard series B

1756-PB72 ControlLogix standard DC 24V DC 18hellip32V DC Standard series A and series B

1756-PB75 24V DC 1832V DC Standard series B

1756-PC75 48V DC 30hellip60V DC Standard series B

1756-PH75 125V DC 90hellip143V DC Standard series B

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PAXT ControlLogix-XT AC power supply 85265V AC 120240V AC XT

1756-PBXT ControlLogix-XT DC power supply 24V DC 18hellip32V DC XT

34 Publication 1756-SG001P-EN-P - May 2011

Redundant Power Supplies

To build a redundant power supply system you need the following

Two redundant power supplies (both 1756-PA75R or 1756-PB75R) One 1756-PSCA2 chassis adapter module Two 1756-CPR2 cables to connect the power supplies to the

1756-PSCA2 chassis adapter module (091 m (3 ft) length) User-supplied annunciator wiring to connect the power supplies to the

input modules as needed

The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Accessories - Redundant Power Supplies

Visualization Products Visualization products together with Logix for control and NetLinx architecture for communication make up the Rockwell Automation Integrated Architecture strategy The visualization strategy combines Rockwell Automation expertise in Allen-Bradley electronic operator interface and industrialized personal computer hardware with Rockwell Software supervisory control software Current visualization products include the following

FactoryTalk View software PanelView Plus operator interface PanelView Plus CE operator interface Industrial computers and monitors

For more information see the Operator Interface catalog pages at httpwwwabcomenepubcatalogs1276221813761239781

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA75R ControlLogix redundant 120V220V AC 85hellip265V AC Standard series B

1756-PB75R 24V DC 192hellip32V DC Standard series B

Cat No Description Specifications

1756-PSCA2 Chassis adapter module Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Mounts directly to left side of 1756 chassis

1756-CPR2 Chassis adapter cable Connects redundant power supply to 1756-PCSA2 chassis adapter Length091 m (3 ft)

Publication 1756-SG001P-EN-P - May 2011 35

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA ltFEFF005500740069006c0069007a007a006100720065002000710075006500730074006500200069006d0070006f007300740061007a0069006f006e00690020007000650072002000630072006500610072006500200064006f00630075006d0065006e00740069002000410064006f006200650020005000440046002000700065007200200075006e00610020007300740061006d007000610020006400690020007100750061006c0069007400e00020007300750020007300740061006d00700061006e0074006900200065002000700072006f006f0066006500720020006400650073006b0074006f0070002e0020004900200064006f00630075006d0065006e007400690020005000440046002000630072006500610074006900200070006f00730073006f006e006f0020006500730073006500720065002000610070006500720074006900200063006f006e0020004100630072006f00620061007400200065002000410064006f00620065002000520065006100640065007200200035002e003000200065002000760065007200730069006f006e006900200073007500630063006500730073006900760065002egt JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

EtherNetIP Communication Modules

The Ethernet Industrial (EtherNetIP) network protocol is an open industrial-networking standard that supports both real-time IO messaging and message exchange The EtherNetIP network uses off-the-shelf Ethernet communication chips and physical media

Accessories - EtherNetIP Network

Cat No Description Media Communication Rate

CIP Motion Axes max

TCPIP Connections

Logix Connections

1756-EN2F EtherNetIP bridge fiber Fiber 100 Mbps 8 128 256

1756-EN2T EtherNetIP bridge copper Copper 10100 Mbps 8 128 256

1756-EN2TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 8 128 256

1756-EN3TR EtherNetIP bridge embedded switch copper

Dual copper 10100 Mbps 255 128 256

1756-ENBT EtherNetIP bridge copper Copper 10100 Mbps mdash 64 128

1756-EWEB Ethernet web server module Copper 10100 Mbps mdash 64 128

1756-EN2TXT ControlLogix-XT extended temperature EtherNetIP bridge copper for extreme environments

Copper 10100 Mbps 8 128 256

Cat No Description Specifications

1585J-M8PBJM-x Ethernet RJ45 patchcordx = 2 (2 m) 5 (5 m) or 10 (10 m)

8-conductor Teal Riser PVC Cable (Flex Rated cable also available)

1585J-M8CC-H RJ45 insulation displacement connector (IDC) 01280325 mm2 (26hellip22 AWG) Cat 6 IDC no tool required

1585J-M8CC-C RJ45 crimp connector with boot qty = 50 pieces 01280205 mm2 (26hellip24 AWG Cat 5e requires crimp tool for assembly

1585A-Jcrimp Crimp tool mdash

9300-RADES Remote access dial-in kit 56 Kbps modem connection to devices on an Ethernet network includes pre-configured modem communication module DIN rail mounting hardware associated cables

Publication 1756-SG001P-EN-P - May 2011 19

Example Configuration - EtherNetIP Network

ControlNet Communication ModulesThe ControlNet network combines the functionality of an IO network and a peer-to-peer network providing high-speed performance The ControlNet network provides deterministic repeatable transfers of critical control data

FirewallRouter

Stratix Switch

Stratix Switch

Stratix Switch

Powermonitor 3000PowerFlex 70

Ethernet PLC-5

MicroLogix

Ethernet SLC 500

1756 IO

1794 IO

1761-NET-ENI

ControlNet

DeviceNet

1734 IO

RSLinxPanelView Plus

1769-L35E CompactLogix

Cat No Description Communication Rate

Logix Connections Number of Nodes

1756-CN2B ControlNet bridge standard media 5 Mbps 128(1) 99

1756-CN2RB ControlNet bridge redundant media 5 Mbps 128(1) 99

1756-CNB ControlNet bridge standard media 5 Mbps 64(2) 99

1756-CNBR ControlNet bridge redundant media 5 Mbps 64(2) 99

1756-CN2RXT ControlLogix-XT extended temperature ControlNet bridge redundant media

5 Mbps 128(1) 99

(1) 128 connections are available for standard use An additional three connections are reserved for redundant control

(2) Recommend using only 4048 Logix connections for IO

20 Publication 1756-SG001P-EN-P - May 2011

Example Configuration - ControlNet Network

Example Configuration - Redundant ControlNet Media

For information on ControlNet media see ControlNet Media System Components List AG-PA002

DeviceNet Communication Module

The DeviceNet network provides connections between simple industrial devices (such as sensors and actuators) and higher-level devices (such as controllers and computers)

1784-U2CNPanelView Plus

1788-CN2DN

DeviceNetPowerFlex 700SPLC-540CControlLogix

Redundant Media

ControlLogix1756-CNBR

ControlNet Node

ControlNet Node

Cat No Description Communication Rate Number of Nodes

1756-DNB DeviceNet bridge 125 Kbps (500 m max)250 Kbps (250 m max)500 Kbps (100 m max)

64

Publication 1756-SG001P-EN-P - May 2011 21

Example Configuration - DeviceNet Network

Accessories - DeviceNet Network

PLC-51771-SDN ControlLogix

1756-DNB

Ultra3000

PanelView Plus1784-U2DN

Ultra5000

IO

Motor starter

PowerFlex AC

Sensor Pushbuttons

LightsBar Code Scanner

Cat No Description

KwikLink Lite flat media KwikLink Lite flat media is a newer ODVA-approved solution for wiring DeviceNet networks Drop-lines for connecting nodes are added by using the KwikLink Lite two-piece connectors This cable system supports the intermixing of DeviceNet cable types (thin-round with flat) All of the KwikLink Lite connectors provide insulation displacement technology with reduced assembly time

KwikLink flat media The KwikLink flat media system provides a modular cabling method with its flat 4-wire cable and insulation displacement connectors (IDCs) The KwikLink system allows nodes to be added to the network without severing the trunkline Cutting or stripping of the trunkline is eliminated as is the need for predetermined cable lengths

Round media Round trunk cable is available in bulk spools or as pre-molded cordsets or patchcords in varying lengths A wide variety of rugged durable DeviceNet components is available for use in round trunk systems Stainless steel versions of round cable system components are also available Thick-trunk round media systems use thick cable for maximum DeviceNet trunk line length Round media thin-trunk systems use thin cable to reduce maximum trunk line distances with a more

compact and cost-effective installation for some applications Thin-cable outer jacket material is TPE for additional chemical resistance

22 Publication 1756-SG001P-EN-P - May 2011

Data Highway Plus and Remote IO Communication Modules

The Data Highway Plus network supports messaging between devices The remote IO link connects to remote IO chassis and other intelligent devices

The 1756-DHRIO module supports messaging between devices on DH+ networks The remote IO functionality enables the module to act as a scanner for transferring digital and block-transfer data to and from remote IO devices

The 1756-RIO module can act as a scanner or adapter on a remote IO network In addition to digital and block-transfer data the 1756-RIO module transfers analog and specialty data without message instructions

Cat No Description Communication Rate DH+ Connections RIO Connections Maximum Recommended Logix Connections

1756-DHRIO Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

1756-RIO Remote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

mdash Remote IO scanner or adapter32 physical racks (076) any combination of rack size and block transfers

10 scheduled IO

1756-DHRIOXT ControlLogix-XT extended temperature Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

Publication 1756-SG001P-EN-P - May 2011 23

Example Configuration - DH+ Network

Example Configuration - Remote IO Network

Accessories - DH+ and Remote IO Networks

PanelView Plus

PLC-5 1784-U2DHPRSLogix 5000

ControlLogix1756-DHRIO

SLC 504

PanelView PlusPLC-5

1791 IO1794 IO

1756-RIO as a Remote IO Adapter

1756-DHRIO as a Remote IO Scanner

Cat No Description Specifications

1770-CD Cable to connect communication module to DH+ network Belden 9463 twinaxial

9300-RADKIT Remote access dial-in kit 56 Kbps modem connection to devices on a DH+ network includes pre-configured modem communication module DIN rail mounting hardware associated cables

24 Publication 1756-SG001P-EN-P - May 2011

FOUNDATION Fieldbus Linking Devices

The FOUNDATION Fieldbus protocol is a network designed for distributed control of process applications

Example Configuration - Bridge to EtherNetIP Network

Cat No Description Communication Rate Number of H1 Ports

Devices per H1 Link

Devices per Linking Device

1757FFLD2 FOUNDATION Fieldbus bridge to an Ethernet network

FOUNDATION Fieldbus 3125 KbpsEtherNetIP 10100 Mbps

2 16(8hellip10 recommended)

32

1757-FFLD4 4 64

1757-FFLDC2 FOUNDATION Fieldbus bridge to a ControlNet network

FOUNDATION Fieldbus 3125 KbpsControlNet 5 Mbps

2 16(8hellip10 recommended)

32

1757-FFLDC4 4 64

FactoryTalk View SERSFieldbusRSLogix 5000

1757-FFLD4

H1(1)

H1(2)H1(3)H1(4)

HSEIP

Publication 1756-SG001P-EN-P - May 2011 25

Example Configuration - Bridge to ControlNet Network

Other Connectivity Options

ControlLogix RedundancyFactoryTalk View SERSFieldbusRSLogix 5000

ControlNet Redundant Media

1757-FFLDC2

FF H1

EtherNetIP

Option Consideration

USB connection The 1756-L7x controller has a USB port in place of the serial port If your application requires RS-232 functionality see the many Encompass partners at httpwwwrockwellautomationcomencompass

Serial connection The serial port on the 1756-L6x controller is compatible with RS-232 serial communication The serial port supports the DF1 protocol to communicate with other devices on the serial linkTo use Logix5000 controllers on Modbus you connect through the serial port and execute a specific ladder logic routine The controller project is available with RSLogix 5000 Enterprise programming software For more information see Using Logix5000 Controllers as Masters or Slaves on Modbus Application Solution publication CIG-AP129

DH-485 network The controller serial port is compatible with DH-485 communication The DH-485 connection does support remote programming and monitoring via RSLogix 5000 softwareOr add a DH-485 communication bridge module (cat no 1756-DH485)

SynchLink network The SynchLink communication module (1756-SYNCH) provides time synchronization and data broadcasting capabilities for distributed motion and coordinated drive control The module connects a ControlLogix chassis to a SynchLink fiber-optic communication link

26 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Controllers The ControlLogix controller provides a scalable controller solution that is capable of addressing a large amount of IO points

The controller can be placed into any slot of a ControlLogix chassis and multiple controllers can be installed in the same chassis Multiple controllers in the same chassis communicate with each other over the backplane (just as controllers can communicate over networks) but operate independently

ControlLogix controllers can monitor and control IO across the ControlLogix backplane as well as over IO links ControlLogix controllers can communicate over EtherNetIP ControlNet DeviceNet DH+ Remote IO and RS-232-C (DF1DH-485 protocol) networks and many third party process and device networks To provide communication for a ControlLogix controller install the appropriate communication interface module into the chassis

For detailed specifications see 1756 ControlLogix Controllers Specifications publication 1756-TD001

Cat No Description User Memory

1756-L72 ControlLogix controller 1 built-in USB port 4 MB

1756-L73 8 MB

1756-L74 16 MB

1756-L75 32 MB

1756-L61 ControlLogix controller 1 built-in RS-232 port 2 MB

1756-L62 4 MB

1756-L63 8 MB

1756-L64 16 MB

1756-L65 32 MB

1756-L61S GuardLogix safety controller 2 MB standard1 MB safety

1756-L62S 4 MB standard1 MB safety

1756-L63S 8 MB standard375 MB safety

1756-LSP GuardLogix safety partner (one is required for each GuardLogix controller) mdash

1756-L63XT ControlLogix-XT controller extreme environment 8 MB

IMPORTANT Scan time for a project loaded in a 1756-L64 or 1756-L65 controller may be slower than for the same project loaded in one of the other 1756-L6x controllers See the Logix5000 Controllers Instruction Execution Time and Memory Use Reference Manual publication 1756-RM087 for instruction execution times

Publication 1756-SG001P-EN-P - May 2011 27

Standard ControlLogix Controllers

The ControlLogix controller is part of the Logix5000 family of controllers A ControlLogix system includes the following

The ControlLogix controller available in different combinations of user memory

RSLogix 5000 programming software 1756 ControlLogix IO modules that reside in a 1756 chassis Separate communication modules for network communication

Features - Standard ControlLogix Controllers

Feature 1756-L61 1756-L62 1756-L63 1756-L64 1756-L65

1756-L72 1756-L73 1756-L74 1756-L75

Controller tasks 32 tasks 100 programstask Event tasks all event triggers

Built-in communication ports 1 port RS-232 serial 1 port USB

Communication options EtherNetIP ControlNet DeviceNet Data Highway Plus Remote IO SynchLink Third-party process and device networks

Built-in port Serial USB

Controller connections supported max 250 500

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Full support

Integrated motion EtherNetIP connection SERCOS interface Analog options (encoder input LDT input SSI input)

Programming languages Relay ladder Structured text Function block SFC

28 Publication 1756-SG001P-EN-P - May 2011

GuardLogix Controllers

A GuardLogix controller is a ControlLogix controller that also provides safety control The GuardLogix system is a dual controller solutionmdashyou must use a 1756-L6xS primary controller and a 1756-LSP safety partner to achieve SIL 3CAT 4

During development safety and standard have the same rules multiple programmers online editing and forcing are all allowed Once the project is tested and ready for final validation you set the Safety Task to a SIL 3 integrity level which is then enforced by the GuardLogix controller When safety memory is locked and protected the safety logic cant be modified and all safety functions operate with SIL 3 integrity On the standard side of the GuardLogix controller all functions operate like a regular Logix controller

Use Guard IO modules for field device connectivity on Ethernet or DeviceNet networks and for safety interlocking between GuardLogix controllers use Ethernet or ControlNet networks Multiple GuardLogix controllers can share safety data for zone to zone interlocking or a single GuardLogix controller can use remote distributed safety IO between different cellsareas

In addition to the standard features of a ControlLogix controller the GuardLogix controller has these safety-related features

Application Description

SIL 1 2 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508 and applications up to and including PLeCat4 according to ISO 13849-1 For more information see GuardLogix Controllers Systems Safety Reference Manual publication 1756-RM093 GuardLogix Controllers User Manual publication 1756-UM020 GuardLogix Safety Application Instruction Set Reference Manual publication 1756-RM095

Features - GuardLogix Controllers

Feature 1756-L61S 1756-L62S 1756-L63S 1756-LSP

Safety communication options Standard and safety EtherNetIP ControlNet DeviceNet

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Not supported

Programming languages Relay ladder

Publication 1756-SG001P-EN-P - May 2011 29

ControlLogix-XT Controllers

The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh corrosive environments

When used with FLEX IO-XT products the ControlLogix-XT system can withstand temperatures range from -2070 C (-4158 F)

When used independently the ControlLogix-XT system can withstand temperature ranges from -2570 C (-13158 F)

Redundant ControlLogix Controllers

The ControlLogix controller supports controller redundancy In a redundant controller system you need these components

Two 1756 chassis each with the following the same ndash Number of slots

ndash Modules in the same slots

ndash Redundancy firmware revisions in each module

ndash Two additional ControlNet nodes outside the redundant chassis pair

You need one of these redundancy modules

One 1756-RM module per chassis that supports the followingndash Two 1756-L61 1756-L62 1761-L63 controllers or one 1756-L64

controller

ndash Maximum of seven communication modules which can be 1756-CN2 series B 1756-CN2R series B and 1756-EN2T modules

ndash One 1756-RMCx cable

One 1757-SRM module per chassis that supports the followingndash One 1756-L61 1756-L62 1756-L63 1756-L64 controller

ndash Maximum of seven communication modules which can be 1756-CNB series D or E 1756-CNBR series D or E 1756-ENBT and 1756-EWEB modules

ndash One 1757-SRCx cable

30 Publication 1756-SG001P-EN-P - May 2011

Accessories - Controllers

Memory Cards

Memory cards offer nonvolatile memory to permanently store a user program and tag data on a controller The 1756-L7x ControlLogix controller comes with 1784-SD1 Secure Digital (SD) card already installed The 1756-L6x controllers support optional CompactFlash cards that you purchase separately The memory card installs in a socket on the controller Through RSLogix 5000 software you can manually trigger the controller to save to or load from nonvolatile memory or configure the controller to load from nonvolatile memory on powerup

The GuardLogix controller does not support user program storage or retrieval by using a CompactFlash card

1756 Energy Storage Modules

Instead of a battery the 1756-L7x controller ships with a 1756-ESMCAP energy storage module (ESM) already installed

Attribute 1784-CF64 1784-CF128 1784-SD1 1784-SD2

Memory 64 MB 128 MB 1 GB 2 GB

Supported controllers 1756-L6x 1756-L7x

Weight approx 142 g (05 oz) 176 g (0062 oz)

Cat No Description

1756-ESMCAP Capacitor-based energy-storage module Comes with the controller

1756-EMNSE ESM without WallClockTime backup power Additionally you can use this ESM with a 1756-L73 (8 MB) or smaller memory-sized controller only

Use this ESM if your application requires that the installed ESM deplete its residual energy to 40 microJoule or less before transporting it into or out of your application

1756-ESMNRM Energy-storage module that secures the controller by preventing the USB connection and SD card useThis ESM provides your application an enhanced degree of security

Publication 1756-SG001P-EN-P - May 2011 31

1756 ControlLogix Batteries

Each 1756-L6x controller ships with a battery With a memory card installed the controller can be used without a battery If you do not use a battery current tag data will be at the state it was when the memory card was saved

ControlLogix Chassis The ControlLogix system is a modular system that requires a 1756 IO chassis Place any module into any slot The backplane provides a high-speed communication path between modules

All of the chassis are designed for horizontal-only back-panel mounting The chassis are available in these configurations

Standard chassis ControlLogix-XT chassis

For detailed specifications see 1756 ControlLogix Chassis Specifications Specifications publication 1756-TD006

Features - Chassis

Slot guides and snap-in retention for easy and secure module fit for any type of 1756 module

Direct mounting accommodates any 1756 power supply

Attribute 1756-BA1 1756-BA2 1756-BATM(1) 1756-BATA

Description Lithium battery (059 g) Lithium battery (059 g) Externally mounted battery assembly

Replacement lithium battery for 1756-BATM (5 g max lithium per each D cell contains 2 D cells)

ControlLogix controllers 1756-L61 1756-L62 1756-L63 series A

1756-L61 1756-L62 1756-L63 series B1756-L64 1756-L65

1756-L61 1756-L62 1756-L63 series A

1756-BATM battery module

GuardLogix controllers mdash 1756-L61S 1756-L62S 1756-L63S

mdash mdash

ControlLogix-XT controllers

mdash 1756-L63XT mdash mdash

(1) The 1756-BATM externally mounted battery assembly is highly recommended for use with all series A 1756-L6x controllers and provides longer battery life than the 1756-BA1 battery The 1756-BATM includes one 1756-BATA lithium battery assembly and a 1 m (328 ft) cable to connect housing to controller

32 Publication 1756-SG001P-EN-P - May 2011

Standard Chassis

The chassis backplane provides a high-speed communication path between modules and distributes power to each of the modules within the chassis

ControlLogix-XT Chassis

The ControlLogix-XT chassis support extreme temperature environments

Accessories - Chassis

Use a slot filler module to fill empty slots

Cat No Description Slots

1756-A4 ControlLogix standard chassis 4

1756-A7 7

1756-A10 10

1756-A13 13

1756-A17 17

Cat No Description Slots Temperature Range

1756-A4LXT ControlLogix-XT chassis 4 -2560 degC (-13140 degF)

1756-A5XT 5 -2570 degC (-13158 degF)

1756-A7LXT 7 -2560 degC (-13140 degF)

Cat No Description

1756-N2 Slot filler module for empty slots in standard ControlLogix chassis

1756-N2XT Slot filler module for empty slots in ControlLogix-XT chassis

Publication 1756-SG001P-EN-P - May 2011 33

ControlLogix Power Supplies

ControlLogix power supplies are used with the 1756 chassis to provide 12V 33V 5V and 24V DC power directly to the chassis backplane Select from these configurations

Standard power Redundant power ControlLogix-XT power

For detailed specifications see 1756 ControlLogix Power Supplies Specifications publication 1756-TD005

Standard Power Supplies

You mount a standard power supply directly on the left end of the chassis where it plugs directly into the backplane

ControlLogix-XT Power Supplies

The ControlLogix-XT power supplies support extreme temperature environments

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA72 ControlLogix standard AC 120V220V AC 85hellip265V AC Standard series A and series B

1756-PA75 120V220V AC 85hellip265V AC Standard series B

1756-PB72 ControlLogix standard DC 24V DC 18hellip32V DC Standard series A and series B

1756-PB75 24V DC 1832V DC Standard series B

1756-PC75 48V DC 30hellip60V DC Standard series B

1756-PH75 125V DC 90hellip143V DC Standard series B

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PAXT ControlLogix-XT AC power supply 85265V AC 120240V AC XT

1756-PBXT ControlLogix-XT DC power supply 24V DC 18hellip32V DC XT

34 Publication 1756-SG001P-EN-P - May 2011

Redundant Power Supplies

To build a redundant power supply system you need the following

Two redundant power supplies (both 1756-PA75R or 1756-PB75R) One 1756-PSCA2 chassis adapter module Two 1756-CPR2 cables to connect the power supplies to the

1756-PSCA2 chassis adapter module (091 m (3 ft) length) User-supplied annunciator wiring to connect the power supplies to the

input modules as needed

The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Accessories - Redundant Power Supplies

Visualization Products Visualization products together with Logix for control and NetLinx architecture for communication make up the Rockwell Automation Integrated Architecture strategy The visualization strategy combines Rockwell Automation expertise in Allen-Bradley electronic operator interface and industrialized personal computer hardware with Rockwell Software supervisory control software Current visualization products include the following

FactoryTalk View software PanelView Plus operator interface PanelView Plus CE operator interface Industrial computers and monitors

For more information see the Operator Interface catalog pages at httpwwwabcomenepubcatalogs1276221813761239781

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA75R ControlLogix redundant 120V220V AC 85hellip265V AC Standard series B

1756-PB75R 24V DC 192hellip32V DC Standard series B

Cat No Description Specifications

1756-PSCA2 Chassis adapter module Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Mounts directly to left side of 1756 chassis

1756-CPR2 Chassis adapter cable Connects redundant power supply to 1756-PCSA2 chassis adapter Length091 m (3 ft)

Publication 1756-SG001P-EN-P - May 2011 35

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO ltFEFF004b00e40079007400e40020006e00e40069007400e4002000610073006500740075006b007300690061002c0020006b0075006e0020006c0075006f0074002000410064006f0062006500200050004400460020002d0064006f006b0075006d0065006e007400740065006a00610020006c0061006100640075006b006100730074006100200074007900f6007000f60079007400e400740075006c006f0073007400750073007400610020006a00610020007600650064006f007300740075007300740061002000760061007200740065006e002e00200020004c0075006f0064007500740020005000440046002d0064006f006b0075006d0065006e00740069007400200076006f0069006400610061006e0020006100760061007400610020004100630072006f0062006100740069006c006c00610020006a0061002000410064006f00620065002000520065006100640065007200200035002e0030003a006c006c00610020006a006100200075007500640065006d006d0069006c006c0061002egt SVE ltFEFF0041006e007600e4006e00640020006400650020006800e4007200200069006e0073007400e4006c006c006e0069006e006700610072006e00610020006f006d002000640075002000760069006c006c00200073006b006100700061002000410064006f006200650020005000440046002d0064006f006b0075006d0065006e00740020006600f600720020006b00760061006c00690074006500740073007500740073006b0072006900660074006500720020007000e5002000760061006e006c00690067006100200073006b0072006900760061007200650020006f006300680020006600f600720020006b006f007200720065006b007400750072002e002000200053006b006100700061006400650020005000440046002d0064006f006b0075006d0065006e00740020006b0061006e002000f600700070006e00610073002000690020004100630072006f0062006100740020006f00630068002000410064006f00620065002000520065006100640065007200200035002e00300020006f00630068002000730065006e006100720065002egt ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

Example Configuration - EtherNetIP Network

ControlNet Communication ModulesThe ControlNet network combines the functionality of an IO network and a peer-to-peer network providing high-speed performance The ControlNet network provides deterministic repeatable transfers of critical control data

FirewallRouter

Stratix Switch

Stratix Switch

Stratix Switch

Powermonitor 3000PowerFlex 70

Ethernet PLC-5

MicroLogix

Ethernet SLC 500

1756 IO

1794 IO

1761-NET-ENI

ControlNet

DeviceNet

1734 IO

RSLinxPanelView Plus

1769-L35E CompactLogix

Cat No Description Communication Rate

Logix Connections Number of Nodes

1756-CN2B ControlNet bridge standard media 5 Mbps 128(1) 99

1756-CN2RB ControlNet bridge redundant media 5 Mbps 128(1) 99

1756-CNB ControlNet bridge standard media 5 Mbps 64(2) 99

1756-CNBR ControlNet bridge redundant media 5 Mbps 64(2) 99

1756-CN2RXT ControlLogix-XT extended temperature ControlNet bridge redundant media

5 Mbps 128(1) 99

(1) 128 connections are available for standard use An additional three connections are reserved for redundant control

(2) Recommend using only 4048 Logix connections for IO

20 Publication 1756-SG001P-EN-P - May 2011

Example Configuration - ControlNet Network

Example Configuration - Redundant ControlNet Media

For information on ControlNet media see ControlNet Media System Components List AG-PA002

DeviceNet Communication Module

The DeviceNet network provides connections between simple industrial devices (such as sensors and actuators) and higher-level devices (such as controllers and computers)

1784-U2CNPanelView Plus

1788-CN2DN

DeviceNetPowerFlex 700SPLC-540CControlLogix

Redundant Media

ControlLogix1756-CNBR

ControlNet Node

ControlNet Node

Cat No Description Communication Rate Number of Nodes

1756-DNB DeviceNet bridge 125 Kbps (500 m max)250 Kbps (250 m max)500 Kbps (100 m max)

64

Publication 1756-SG001P-EN-P - May 2011 21

Example Configuration - DeviceNet Network

Accessories - DeviceNet Network

PLC-51771-SDN ControlLogix

1756-DNB

Ultra3000

PanelView Plus1784-U2DN

Ultra5000

IO

Motor starter

PowerFlex AC

Sensor Pushbuttons

LightsBar Code Scanner

Cat No Description

KwikLink Lite flat media KwikLink Lite flat media is a newer ODVA-approved solution for wiring DeviceNet networks Drop-lines for connecting nodes are added by using the KwikLink Lite two-piece connectors This cable system supports the intermixing of DeviceNet cable types (thin-round with flat) All of the KwikLink Lite connectors provide insulation displacement technology with reduced assembly time

KwikLink flat media The KwikLink flat media system provides a modular cabling method with its flat 4-wire cable and insulation displacement connectors (IDCs) The KwikLink system allows nodes to be added to the network without severing the trunkline Cutting or stripping of the trunkline is eliminated as is the need for predetermined cable lengths

Round media Round trunk cable is available in bulk spools or as pre-molded cordsets or patchcords in varying lengths A wide variety of rugged durable DeviceNet components is available for use in round trunk systems Stainless steel versions of round cable system components are also available Thick-trunk round media systems use thick cable for maximum DeviceNet trunk line length Round media thin-trunk systems use thin cable to reduce maximum trunk line distances with a more

compact and cost-effective installation for some applications Thin-cable outer jacket material is TPE for additional chemical resistance

22 Publication 1756-SG001P-EN-P - May 2011

Data Highway Plus and Remote IO Communication Modules

The Data Highway Plus network supports messaging between devices The remote IO link connects to remote IO chassis and other intelligent devices

The 1756-DHRIO module supports messaging between devices on DH+ networks The remote IO functionality enables the module to act as a scanner for transferring digital and block-transfer data to and from remote IO devices

The 1756-RIO module can act as a scanner or adapter on a remote IO network In addition to digital and block-transfer data the 1756-RIO module transfers analog and specialty data without message instructions

Cat No Description Communication Rate DH+ Connections RIO Connections Maximum Recommended Logix Connections

1756-DHRIO Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

1756-RIO Remote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

mdash Remote IO scanner or adapter32 physical racks (076) any combination of rack size and block transfers

10 scheduled IO

1756-DHRIOXT ControlLogix-XT extended temperature Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

Publication 1756-SG001P-EN-P - May 2011 23

Example Configuration - DH+ Network

Example Configuration - Remote IO Network

Accessories - DH+ and Remote IO Networks

PanelView Plus

PLC-5 1784-U2DHPRSLogix 5000

ControlLogix1756-DHRIO

SLC 504

PanelView PlusPLC-5

1791 IO1794 IO

1756-RIO as a Remote IO Adapter

1756-DHRIO as a Remote IO Scanner

Cat No Description Specifications

1770-CD Cable to connect communication module to DH+ network Belden 9463 twinaxial

9300-RADKIT Remote access dial-in kit 56 Kbps modem connection to devices on a DH+ network includes pre-configured modem communication module DIN rail mounting hardware associated cables

24 Publication 1756-SG001P-EN-P - May 2011

FOUNDATION Fieldbus Linking Devices

The FOUNDATION Fieldbus protocol is a network designed for distributed control of process applications

Example Configuration - Bridge to EtherNetIP Network

Cat No Description Communication Rate Number of H1 Ports

Devices per H1 Link

Devices per Linking Device

1757FFLD2 FOUNDATION Fieldbus bridge to an Ethernet network

FOUNDATION Fieldbus 3125 KbpsEtherNetIP 10100 Mbps

2 16(8hellip10 recommended)

32

1757-FFLD4 4 64

1757-FFLDC2 FOUNDATION Fieldbus bridge to a ControlNet network

FOUNDATION Fieldbus 3125 KbpsControlNet 5 Mbps

2 16(8hellip10 recommended)

32

1757-FFLDC4 4 64

FactoryTalk View SERSFieldbusRSLogix 5000

1757-FFLD4

H1(1)

H1(2)H1(3)H1(4)

HSEIP

Publication 1756-SG001P-EN-P - May 2011 25

Example Configuration - Bridge to ControlNet Network

Other Connectivity Options

ControlLogix RedundancyFactoryTalk View SERSFieldbusRSLogix 5000

ControlNet Redundant Media

1757-FFLDC2

FF H1

EtherNetIP

Option Consideration

USB connection The 1756-L7x controller has a USB port in place of the serial port If your application requires RS-232 functionality see the many Encompass partners at httpwwwrockwellautomationcomencompass

Serial connection The serial port on the 1756-L6x controller is compatible with RS-232 serial communication The serial port supports the DF1 protocol to communicate with other devices on the serial linkTo use Logix5000 controllers on Modbus you connect through the serial port and execute a specific ladder logic routine The controller project is available with RSLogix 5000 Enterprise programming software For more information see Using Logix5000 Controllers as Masters or Slaves on Modbus Application Solution publication CIG-AP129

DH-485 network The controller serial port is compatible with DH-485 communication The DH-485 connection does support remote programming and monitoring via RSLogix 5000 softwareOr add a DH-485 communication bridge module (cat no 1756-DH485)

SynchLink network The SynchLink communication module (1756-SYNCH) provides time synchronization and data broadcasting capabilities for distributed motion and coordinated drive control The module connects a ControlLogix chassis to a SynchLink fiber-optic communication link

26 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Controllers The ControlLogix controller provides a scalable controller solution that is capable of addressing a large amount of IO points

The controller can be placed into any slot of a ControlLogix chassis and multiple controllers can be installed in the same chassis Multiple controllers in the same chassis communicate with each other over the backplane (just as controllers can communicate over networks) but operate independently

ControlLogix controllers can monitor and control IO across the ControlLogix backplane as well as over IO links ControlLogix controllers can communicate over EtherNetIP ControlNet DeviceNet DH+ Remote IO and RS-232-C (DF1DH-485 protocol) networks and many third party process and device networks To provide communication for a ControlLogix controller install the appropriate communication interface module into the chassis

For detailed specifications see 1756 ControlLogix Controllers Specifications publication 1756-TD001

Cat No Description User Memory

1756-L72 ControlLogix controller 1 built-in USB port 4 MB

1756-L73 8 MB

1756-L74 16 MB

1756-L75 32 MB

1756-L61 ControlLogix controller 1 built-in RS-232 port 2 MB

1756-L62 4 MB

1756-L63 8 MB

1756-L64 16 MB

1756-L65 32 MB

1756-L61S GuardLogix safety controller 2 MB standard1 MB safety

1756-L62S 4 MB standard1 MB safety

1756-L63S 8 MB standard375 MB safety

1756-LSP GuardLogix safety partner (one is required for each GuardLogix controller) mdash

1756-L63XT ControlLogix-XT controller extreme environment 8 MB

IMPORTANT Scan time for a project loaded in a 1756-L64 or 1756-L65 controller may be slower than for the same project loaded in one of the other 1756-L6x controllers See the Logix5000 Controllers Instruction Execution Time and Memory Use Reference Manual publication 1756-RM087 for instruction execution times

Publication 1756-SG001P-EN-P - May 2011 27

Standard ControlLogix Controllers

The ControlLogix controller is part of the Logix5000 family of controllers A ControlLogix system includes the following

The ControlLogix controller available in different combinations of user memory

RSLogix 5000 programming software 1756 ControlLogix IO modules that reside in a 1756 chassis Separate communication modules for network communication

Features - Standard ControlLogix Controllers

Feature 1756-L61 1756-L62 1756-L63 1756-L64 1756-L65

1756-L72 1756-L73 1756-L74 1756-L75

Controller tasks 32 tasks 100 programstask Event tasks all event triggers

Built-in communication ports 1 port RS-232 serial 1 port USB

Communication options EtherNetIP ControlNet DeviceNet Data Highway Plus Remote IO SynchLink Third-party process and device networks

Built-in port Serial USB

Controller connections supported max 250 500

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Full support

Integrated motion EtherNetIP connection SERCOS interface Analog options (encoder input LDT input SSI input)

Programming languages Relay ladder Structured text Function block SFC

28 Publication 1756-SG001P-EN-P - May 2011

GuardLogix Controllers

A GuardLogix controller is a ControlLogix controller that also provides safety control The GuardLogix system is a dual controller solutionmdashyou must use a 1756-L6xS primary controller and a 1756-LSP safety partner to achieve SIL 3CAT 4

During development safety and standard have the same rules multiple programmers online editing and forcing are all allowed Once the project is tested and ready for final validation you set the Safety Task to a SIL 3 integrity level which is then enforced by the GuardLogix controller When safety memory is locked and protected the safety logic cant be modified and all safety functions operate with SIL 3 integrity On the standard side of the GuardLogix controller all functions operate like a regular Logix controller

Use Guard IO modules for field device connectivity on Ethernet or DeviceNet networks and for safety interlocking between GuardLogix controllers use Ethernet or ControlNet networks Multiple GuardLogix controllers can share safety data for zone to zone interlocking or a single GuardLogix controller can use remote distributed safety IO between different cellsareas

In addition to the standard features of a ControlLogix controller the GuardLogix controller has these safety-related features

Application Description

SIL 1 2 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508 and applications up to and including PLeCat4 according to ISO 13849-1 For more information see GuardLogix Controllers Systems Safety Reference Manual publication 1756-RM093 GuardLogix Controllers User Manual publication 1756-UM020 GuardLogix Safety Application Instruction Set Reference Manual publication 1756-RM095

Features - GuardLogix Controllers

Feature 1756-L61S 1756-L62S 1756-L63S 1756-LSP

Safety communication options Standard and safety EtherNetIP ControlNet DeviceNet

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Not supported

Programming languages Relay ladder

Publication 1756-SG001P-EN-P - May 2011 29

ControlLogix-XT Controllers

The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh corrosive environments

When used with FLEX IO-XT products the ControlLogix-XT system can withstand temperatures range from -2070 C (-4158 F)

When used independently the ControlLogix-XT system can withstand temperature ranges from -2570 C (-13158 F)

Redundant ControlLogix Controllers

The ControlLogix controller supports controller redundancy In a redundant controller system you need these components

Two 1756 chassis each with the following the same ndash Number of slots

ndash Modules in the same slots

ndash Redundancy firmware revisions in each module

ndash Two additional ControlNet nodes outside the redundant chassis pair

You need one of these redundancy modules

One 1756-RM module per chassis that supports the followingndash Two 1756-L61 1756-L62 1761-L63 controllers or one 1756-L64

controller

ndash Maximum of seven communication modules which can be 1756-CN2 series B 1756-CN2R series B and 1756-EN2T modules

ndash One 1756-RMCx cable

One 1757-SRM module per chassis that supports the followingndash One 1756-L61 1756-L62 1756-L63 1756-L64 controller

ndash Maximum of seven communication modules which can be 1756-CNB series D or E 1756-CNBR series D or E 1756-ENBT and 1756-EWEB modules

ndash One 1757-SRCx cable

30 Publication 1756-SG001P-EN-P - May 2011

Accessories - Controllers

Memory Cards

Memory cards offer nonvolatile memory to permanently store a user program and tag data on a controller The 1756-L7x ControlLogix controller comes with 1784-SD1 Secure Digital (SD) card already installed The 1756-L6x controllers support optional CompactFlash cards that you purchase separately The memory card installs in a socket on the controller Through RSLogix 5000 software you can manually trigger the controller to save to or load from nonvolatile memory or configure the controller to load from nonvolatile memory on powerup

The GuardLogix controller does not support user program storage or retrieval by using a CompactFlash card

1756 Energy Storage Modules

Instead of a battery the 1756-L7x controller ships with a 1756-ESMCAP energy storage module (ESM) already installed

Attribute 1784-CF64 1784-CF128 1784-SD1 1784-SD2

Memory 64 MB 128 MB 1 GB 2 GB

Supported controllers 1756-L6x 1756-L7x

Weight approx 142 g (05 oz) 176 g (0062 oz)

Cat No Description

1756-ESMCAP Capacitor-based energy-storage module Comes with the controller

1756-EMNSE ESM without WallClockTime backup power Additionally you can use this ESM with a 1756-L73 (8 MB) or smaller memory-sized controller only

Use this ESM if your application requires that the installed ESM deplete its residual energy to 40 microJoule or less before transporting it into or out of your application

1756-ESMNRM Energy-storage module that secures the controller by preventing the USB connection and SD card useThis ESM provides your application an enhanced degree of security

Publication 1756-SG001P-EN-P - May 2011 31

1756 ControlLogix Batteries

Each 1756-L6x controller ships with a battery With a memory card installed the controller can be used without a battery If you do not use a battery current tag data will be at the state it was when the memory card was saved

ControlLogix Chassis The ControlLogix system is a modular system that requires a 1756 IO chassis Place any module into any slot The backplane provides a high-speed communication path between modules

All of the chassis are designed for horizontal-only back-panel mounting The chassis are available in these configurations

Standard chassis ControlLogix-XT chassis

For detailed specifications see 1756 ControlLogix Chassis Specifications Specifications publication 1756-TD006

Features - Chassis

Slot guides and snap-in retention for easy and secure module fit for any type of 1756 module

Direct mounting accommodates any 1756 power supply

Attribute 1756-BA1 1756-BA2 1756-BATM(1) 1756-BATA

Description Lithium battery (059 g) Lithium battery (059 g) Externally mounted battery assembly

Replacement lithium battery for 1756-BATM (5 g max lithium per each D cell contains 2 D cells)

ControlLogix controllers 1756-L61 1756-L62 1756-L63 series A

1756-L61 1756-L62 1756-L63 series B1756-L64 1756-L65

1756-L61 1756-L62 1756-L63 series A

1756-BATM battery module

GuardLogix controllers mdash 1756-L61S 1756-L62S 1756-L63S

mdash mdash

ControlLogix-XT controllers

mdash 1756-L63XT mdash mdash

(1) The 1756-BATM externally mounted battery assembly is highly recommended for use with all series A 1756-L6x controllers and provides longer battery life than the 1756-BA1 battery The 1756-BATM includes one 1756-BATA lithium battery assembly and a 1 m (328 ft) cable to connect housing to controller

32 Publication 1756-SG001P-EN-P - May 2011

Standard Chassis

The chassis backplane provides a high-speed communication path between modules and distributes power to each of the modules within the chassis

ControlLogix-XT Chassis

The ControlLogix-XT chassis support extreme temperature environments

Accessories - Chassis

Use a slot filler module to fill empty slots

Cat No Description Slots

1756-A4 ControlLogix standard chassis 4

1756-A7 7

1756-A10 10

1756-A13 13

1756-A17 17

Cat No Description Slots Temperature Range

1756-A4LXT ControlLogix-XT chassis 4 -2560 degC (-13140 degF)

1756-A5XT 5 -2570 degC (-13158 degF)

1756-A7LXT 7 -2560 degC (-13140 degF)

Cat No Description

1756-N2 Slot filler module for empty slots in standard ControlLogix chassis

1756-N2XT Slot filler module for empty slots in ControlLogix-XT chassis

Publication 1756-SG001P-EN-P - May 2011 33

ControlLogix Power Supplies

ControlLogix power supplies are used with the 1756 chassis to provide 12V 33V 5V and 24V DC power directly to the chassis backplane Select from these configurations

Standard power Redundant power ControlLogix-XT power

For detailed specifications see 1756 ControlLogix Power Supplies Specifications publication 1756-TD005

Standard Power Supplies

You mount a standard power supply directly on the left end of the chassis where it plugs directly into the backplane

ControlLogix-XT Power Supplies

The ControlLogix-XT power supplies support extreme temperature environments

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA72 ControlLogix standard AC 120V220V AC 85hellip265V AC Standard series A and series B

1756-PA75 120V220V AC 85hellip265V AC Standard series B

1756-PB72 ControlLogix standard DC 24V DC 18hellip32V DC Standard series A and series B

1756-PB75 24V DC 1832V DC Standard series B

1756-PC75 48V DC 30hellip60V DC Standard series B

1756-PH75 125V DC 90hellip143V DC Standard series B

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PAXT ControlLogix-XT AC power supply 85265V AC 120240V AC XT

1756-PBXT ControlLogix-XT DC power supply 24V DC 18hellip32V DC XT

34 Publication 1756-SG001P-EN-P - May 2011

Redundant Power Supplies

To build a redundant power supply system you need the following

Two redundant power supplies (both 1756-PA75R or 1756-PB75R) One 1756-PSCA2 chassis adapter module Two 1756-CPR2 cables to connect the power supplies to the

1756-PSCA2 chassis adapter module (091 m (3 ft) length) User-supplied annunciator wiring to connect the power supplies to the

input modules as needed

The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Accessories - Redundant Power Supplies

Visualization Products Visualization products together with Logix for control and NetLinx architecture for communication make up the Rockwell Automation Integrated Architecture strategy The visualization strategy combines Rockwell Automation expertise in Allen-Bradley electronic operator interface and industrialized personal computer hardware with Rockwell Software supervisory control software Current visualization products include the following

FactoryTalk View software PanelView Plus operator interface PanelView Plus CE operator interface Industrial computers and monitors

For more information see the Operator Interface catalog pages at httpwwwabcomenepubcatalogs1276221813761239781

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA75R ControlLogix redundant 120V220V AC 85hellip265V AC Standard series B

1756-PB75R 24V DC 192hellip32V DC Standard series B

Cat No Description Specifications

1756-PSCA2 Chassis adapter module Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Mounts directly to left side of 1756 chassis

1756-CPR2 Chassis adapter cable Connects redundant power supply to 1756-PCSA2 chassis adapter Length091 m (3 ft)

Publication 1756-SG001P-EN-P - May 2011 35

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE ltFEFF0041006e007600e4006e00640020006400650020006800e4007200200069006e0073007400e4006c006c006e0069006e006700610072006e00610020006f006d002000640075002000760069006c006c00200073006b006100700061002000410064006f006200650020005000440046002d0064006f006b0075006d0065006e00740020006600f600720020006b00760061006c00690074006500740073007500740073006b0072006900660074006500720020007000e5002000760061006e006c00690067006100200073006b0072006900760061007200650020006f006300680020006600f600720020006b006f007200720065006b007400750072002e002000200053006b006100700061006400650020005000440046002d0064006f006b0075006d0065006e00740020006b0061006e002000f600700070006e00610073002000690020004100630072006f0062006100740020006f00630068002000410064006f00620065002000520065006100640065007200200035002e00300020006f00630068002000730065006e006100720065002egt ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

Example Configuration - ControlNet Network

Example Configuration - Redundant ControlNet Media

For information on ControlNet media see ControlNet Media System Components List AG-PA002

DeviceNet Communication Module

The DeviceNet network provides connections between simple industrial devices (such as sensors and actuators) and higher-level devices (such as controllers and computers)

1784-U2CNPanelView Plus

1788-CN2DN

DeviceNetPowerFlex 700SPLC-540CControlLogix

Redundant Media

ControlLogix1756-CNBR

ControlNet Node

ControlNet Node

Cat No Description Communication Rate Number of Nodes

1756-DNB DeviceNet bridge 125 Kbps (500 m max)250 Kbps (250 m max)500 Kbps (100 m max)

64

Publication 1756-SG001P-EN-P - May 2011 21

Example Configuration - DeviceNet Network

Accessories - DeviceNet Network

PLC-51771-SDN ControlLogix

1756-DNB

Ultra3000

PanelView Plus1784-U2DN

Ultra5000

IO

Motor starter

PowerFlex AC

Sensor Pushbuttons

LightsBar Code Scanner

Cat No Description

KwikLink Lite flat media KwikLink Lite flat media is a newer ODVA-approved solution for wiring DeviceNet networks Drop-lines for connecting nodes are added by using the KwikLink Lite two-piece connectors This cable system supports the intermixing of DeviceNet cable types (thin-round with flat) All of the KwikLink Lite connectors provide insulation displacement technology with reduced assembly time

KwikLink flat media The KwikLink flat media system provides a modular cabling method with its flat 4-wire cable and insulation displacement connectors (IDCs) The KwikLink system allows nodes to be added to the network without severing the trunkline Cutting or stripping of the trunkline is eliminated as is the need for predetermined cable lengths

Round media Round trunk cable is available in bulk spools or as pre-molded cordsets or patchcords in varying lengths A wide variety of rugged durable DeviceNet components is available for use in round trunk systems Stainless steel versions of round cable system components are also available Thick-trunk round media systems use thick cable for maximum DeviceNet trunk line length Round media thin-trunk systems use thin cable to reduce maximum trunk line distances with a more

compact and cost-effective installation for some applications Thin-cable outer jacket material is TPE for additional chemical resistance

22 Publication 1756-SG001P-EN-P - May 2011

Data Highway Plus and Remote IO Communication Modules

The Data Highway Plus network supports messaging between devices The remote IO link connects to remote IO chassis and other intelligent devices

The 1756-DHRIO module supports messaging between devices on DH+ networks The remote IO functionality enables the module to act as a scanner for transferring digital and block-transfer data to and from remote IO devices

The 1756-RIO module can act as a scanner or adapter on a remote IO network In addition to digital and block-transfer data the 1756-RIO module transfers analog and specialty data without message instructions

Cat No Description Communication Rate DH+ Connections RIO Connections Maximum Recommended Logix Connections

1756-DHRIO Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

1756-RIO Remote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

mdash Remote IO scanner or adapter32 physical racks (076) any combination of rack size and block transfers

10 scheduled IO

1756-DHRIOXT ControlLogix-XT extended temperature Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

Publication 1756-SG001P-EN-P - May 2011 23

Example Configuration - DH+ Network

Example Configuration - Remote IO Network

Accessories - DH+ and Remote IO Networks

PanelView Plus

PLC-5 1784-U2DHPRSLogix 5000

ControlLogix1756-DHRIO

SLC 504

PanelView PlusPLC-5

1791 IO1794 IO

1756-RIO as a Remote IO Adapter

1756-DHRIO as a Remote IO Scanner

Cat No Description Specifications

1770-CD Cable to connect communication module to DH+ network Belden 9463 twinaxial

9300-RADKIT Remote access dial-in kit 56 Kbps modem connection to devices on a DH+ network includes pre-configured modem communication module DIN rail mounting hardware associated cables

24 Publication 1756-SG001P-EN-P - May 2011

FOUNDATION Fieldbus Linking Devices

The FOUNDATION Fieldbus protocol is a network designed for distributed control of process applications

Example Configuration - Bridge to EtherNetIP Network

Cat No Description Communication Rate Number of H1 Ports

Devices per H1 Link

Devices per Linking Device

1757FFLD2 FOUNDATION Fieldbus bridge to an Ethernet network

FOUNDATION Fieldbus 3125 KbpsEtherNetIP 10100 Mbps

2 16(8hellip10 recommended)

32

1757-FFLD4 4 64

1757-FFLDC2 FOUNDATION Fieldbus bridge to a ControlNet network

FOUNDATION Fieldbus 3125 KbpsControlNet 5 Mbps

2 16(8hellip10 recommended)

32

1757-FFLDC4 4 64

FactoryTalk View SERSFieldbusRSLogix 5000

1757-FFLD4

H1(1)

H1(2)H1(3)H1(4)

HSEIP

Publication 1756-SG001P-EN-P - May 2011 25

Example Configuration - Bridge to ControlNet Network

Other Connectivity Options

ControlLogix RedundancyFactoryTalk View SERSFieldbusRSLogix 5000

ControlNet Redundant Media

1757-FFLDC2

FF H1

EtherNetIP

Option Consideration

USB connection The 1756-L7x controller has a USB port in place of the serial port If your application requires RS-232 functionality see the many Encompass partners at httpwwwrockwellautomationcomencompass

Serial connection The serial port on the 1756-L6x controller is compatible with RS-232 serial communication The serial port supports the DF1 protocol to communicate with other devices on the serial linkTo use Logix5000 controllers on Modbus you connect through the serial port and execute a specific ladder logic routine The controller project is available with RSLogix 5000 Enterprise programming software For more information see Using Logix5000 Controllers as Masters or Slaves on Modbus Application Solution publication CIG-AP129

DH-485 network The controller serial port is compatible with DH-485 communication The DH-485 connection does support remote programming and monitoring via RSLogix 5000 softwareOr add a DH-485 communication bridge module (cat no 1756-DH485)

SynchLink network The SynchLink communication module (1756-SYNCH) provides time synchronization and data broadcasting capabilities for distributed motion and coordinated drive control The module connects a ControlLogix chassis to a SynchLink fiber-optic communication link

26 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Controllers The ControlLogix controller provides a scalable controller solution that is capable of addressing a large amount of IO points

The controller can be placed into any slot of a ControlLogix chassis and multiple controllers can be installed in the same chassis Multiple controllers in the same chassis communicate with each other over the backplane (just as controllers can communicate over networks) but operate independently

ControlLogix controllers can monitor and control IO across the ControlLogix backplane as well as over IO links ControlLogix controllers can communicate over EtherNetIP ControlNet DeviceNet DH+ Remote IO and RS-232-C (DF1DH-485 protocol) networks and many third party process and device networks To provide communication for a ControlLogix controller install the appropriate communication interface module into the chassis

For detailed specifications see 1756 ControlLogix Controllers Specifications publication 1756-TD001

Cat No Description User Memory

1756-L72 ControlLogix controller 1 built-in USB port 4 MB

1756-L73 8 MB

1756-L74 16 MB

1756-L75 32 MB

1756-L61 ControlLogix controller 1 built-in RS-232 port 2 MB

1756-L62 4 MB

1756-L63 8 MB

1756-L64 16 MB

1756-L65 32 MB

1756-L61S GuardLogix safety controller 2 MB standard1 MB safety

1756-L62S 4 MB standard1 MB safety

1756-L63S 8 MB standard375 MB safety

1756-LSP GuardLogix safety partner (one is required for each GuardLogix controller) mdash

1756-L63XT ControlLogix-XT controller extreme environment 8 MB

IMPORTANT Scan time for a project loaded in a 1756-L64 or 1756-L65 controller may be slower than for the same project loaded in one of the other 1756-L6x controllers See the Logix5000 Controllers Instruction Execution Time and Memory Use Reference Manual publication 1756-RM087 for instruction execution times

Publication 1756-SG001P-EN-P - May 2011 27

Standard ControlLogix Controllers

The ControlLogix controller is part of the Logix5000 family of controllers A ControlLogix system includes the following

The ControlLogix controller available in different combinations of user memory

RSLogix 5000 programming software 1756 ControlLogix IO modules that reside in a 1756 chassis Separate communication modules for network communication

Features - Standard ControlLogix Controllers

Feature 1756-L61 1756-L62 1756-L63 1756-L64 1756-L65

1756-L72 1756-L73 1756-L74 1756-L75

Controller tasks 32 tasks 100 programstask Event tasks all event triggers

Built-in communication ports 1 port RS-232 serial 1 port USB

Communication options EtherNetIP ControlNet DeviceNet Data Highway Plus Remote IO SynchLink Third-party process and device networks

Built-in port Serial USB

Controller connections supported max 250 500

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Full support

Integrated motion EtherNetIP connection SERCOS interface Analog options (encoder input LDT input SSI input)

Programming languages Relay ladder Structured text Function block SFC

28 Publication 1756-SG001P-EN-P - May 2011

GuardLogix Controllers

A GuardLogix controller is a ControlLogix controller that also provides safety control The GuardLogix system is a dual controller solutionmdashyou must use a 1756-L6xS primary controller and a 1756-LSP safety partner to achieve SIL 3CAT 4

During development safety and standard have the same rules multiple programmers online editing and forcing are all allowed Once the project is tested and ready for final validation you set the Safety Task to a SIL 3 integrity level which is then enforced by the GuardLogix controller When safety memory is locked and protected the safety logic cant be modified and all safety functions operate with SIL 3 integrity On the standard side of the GuardLogix controller all functions operate like a regular Logix controller

Use Guard IO modules for field device connectivity on Ethernet or DeviceNet networks and for safety interlocking between GuardLogix controllers use Ethernet or ControlNet networks Multiple GuardLogix controllers can share safety data for zone to zone interlocking or a single GuardLogix controller can use remote distributed safety IO between different cellsareas

In addition to the standard features of a ControlLogix controller the GuardLogix controller has these safety-related features

Application Description

SIL 1 2 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508 and applications up to and including PLeCat4 according to ISO 13849-1 For more information see GuardLogix Controllers Systems Safety Reference Manual publication 1756-RM093 GuardLogix Controllers User Manual publication 1756-UM020 GuardLogix Safety Application Instruction Set Reference Manual publication 1756-RM095

Features - GuardLogix Controllers

Feature 1756-L61S 1756-L62S 1756-L63S 1756-LSP

Safety communication options Standard and safety EtherNetIP ControlNet DeviceNet

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Not supported

Programming languages Relay ladder

Publication 1756-SG001P-EN-P - May 2011 29

ControlLogix-XT Controllers

The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh corrosive environments

When used with FLEX IO-XT products the ControlLogix-XT system can withstand temperatures range from -2070 C (-4158 F)

When used independently the ControlLogix-XT system can withstand temperature ranges from -2570 C (-13158 F)

Redundant ControlLogix Controllers

The ControlLogix controller supports controller redundancy In a redundant controller system you need these components

Two 1756 chassis each with the following the same ndash Number of slots

ndash Modules in the same slots

ndash Redundancy firmware revisions in each module

ndash Two additional ControlNet nodes outside the redundant chassis pair

You need one of these redundancy modules

One 1756-RM module per chassis that supports the followingndash Two 1756-L61 1756-L62 1761-L63 controllers or one 1756-L64

controller

ndash Maximum of seven communication modules which can be 1756-CN2 series B 1756-CN2R series B and 1756-EN2T modules

ndash One 1756-RMCx cable

One 1757-SRM module per chassis that supports the followingndash One 1756-L61 1756-L62 1756-L63 1756-L64 controller

ndash Maximum of seven communication modules which can be 1756-CNB series D or E 1756-CNBR series D or E 1756-ENBT and 1756-EWEB modules

ndash One 1757-SRCx cable

30 Publication 1756-SG001P-EN-P - May 2011

Accessories - Controllers

Memory Cards

Memory cards offer nonvolatile memory to permanently store a user program and tag data on a controller The 1756-L7x ControlLogix controller comes with 1784-SD1 Secure Digital (SD) card already installed The 1756-L6x controllers support optional CompactFlash cards that you purchase separately The memory card installs in a socket on the controller Through RSLogix 5000 software you can manually trigger the controller to save to or load from nonvolatile memory or configure the controller to load from nonvolatile memory on powerup

The GuardLogix controller does not support user program storage or retrieval by using a CompactFlash card

1756 Energy Storage Modules

Instead of a battery the 1756-L7x controller ships with a 1756-ESMCAP energy storage module (ESM) already installed

Attribute 1784-CF64 1784-CF128 1784-SD1 1784-SD2

Memory 64 MB 128 MB 1 GB 2 GB

Supported controllers 1756-L6x 1756-L7x

Weight approx 142 g (05 oz) 176 g (0062 oz)

Cat No Description

1756-ESMCAP Capacitor-based energy-storage module Comes with the controller

1756-EMNSE ESM without WallClockTime backup power Additionally you can use this ESM with a 1756-L73 (8 MB) or smaller memory-sized controller only

Use this ESM if your application requires that the installed ESM deplete its residual energy to 40 microJoule or less before transporting it into or out of your application

1756-ESMNRM Energy-storage module that secures the controller by preventing the USB connection and SD card useThis ESM provides your application an enhanced degree of security

Publication 1756-SG001P-EN-P - May 2011 31

1756 ControlLogix Batteries

Each 1756-L6x controller ships with a battery With a memory card installed the controller can be used without a battery If you do not use a battery current tag data will be at the state it was when the memory card was saved

ControlLogix Chassis The ControlLogix system is a modular system that requires a 1756 IO chassis Place any module into any slot The backplane provides a high-speed communication path between modules

All of the chassis are designed for horizontal-only back-panel mounting The chassis are available in these configurations

Standard chassis ControlLogix-XT chassis

For detailed specifications see 1756 ControlLogix Chassis Specifications Specifications publication 1756-TD006

Features - Chassis

Slot guides and snap-in retention for easy and secure module fit for any type of 1756 module

Direct mounting accommodates any 1756 power supply

Attribute 1756-BA1 1756-BA2 1756-BATM(1) 1756-BATA

Description Lithium battery (059 g) Lithium battery (059 g) Externally mounted battery assembly

Replacement lithium battery for 1756-BATM (5 g max lithium per each D cell contains 2 D cells)

ControlLogix controllers 1756-L61 1756-L62 1756-L63 series A

1756-L61 1756-L62 1756-L63 series B1756-L64 1756-L65

1756-L61 1756-L62 1756-L63 series A

1756-BATM battery module

GuardLogix controllers mdash 1756-L61S 1756-L62S 1756-L63S

mdash mdash

ControlLogix-XT controllers

mdash 1756-L63XT mdash mdash

(1) The 1756-BATM externally mounted battery assembly is highly recommended for use with all series A 1756-L6x controllers and provides longer battery life than the 1756-BA1 battery The 1756-BATM includes one 1756-BATA lithium battery assembly and a 1 m (328 ft) cable to connect housing to controller

32 Publication 1756-SG001P-EN-P - May 2011

Standard Chassis

The chassis backplane provides a high-speed communication path between modules and distributes power to each of the modules within the chassis

ControlLogix-XT Chassis

The ControlLogix-XT chassis support extreme temperature environments

Accessories - Chassis

Use a slot filler module to fill empty slots

Cat No Description Slots

1756-A4 ControlLogix standard chassis 4

1756-A7 7

1756-A10 10

1756-A13 13

1756-A17 17

Cat No Description Slots Temperature Range

1756-A4LXT ControlLogix-XT chassis 4 -2560 degC (-13140 degF)

1756-A5XT 5 -2570 degC (-13158 degF)

1756-A7LXT 7 -2560 degC (-13140 degF)

Cat No Description

1756-N2 Slot filler module for empty slots in standard ControlLogix chassis

1756-N2XT Slot filler module for empty slots in ControlLogix-XT chassis

Publication 1756-SG001P-EN-P - May 2011 33

ControlLogix Power Supplies

ControlLogix power supplies are used with the 1756 chassis to provide 12V 33V 5V and 24V DC power directly to the chassis backplane Select from these configurations

Standard power Redundant power ControlLogix-XT power

For detailed specifications see 1756 ControlLogix Power Supplies Specifications publication 1756-TD005

Standard Power Supplies

You mount a standard power supply directly on the left end of the chassis where it plugs directly into the backplane

ControlLogix-XT Power Supplies

The ControlLogix-XT power supplies support extreme temperature environments

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA72 ControlLogix standard AC 120V220V AC 85hellip265V AC Standard series A and series B

1756-PA75 120V220V AC 85hellip265V AC Standard series B

1756-PB72 ControlLogix standard DC 24V DC 18hellip32V DC Standard series A and series B

1756-PB75 24V DC 1832V DC Standard series B

1756-PC75 48V DC 30hellip60V DC Standard series B

1756-PH75 125V DC 90hellip143V DC Standard series B

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PAXT ControlLogix-XT AC power supply 85265V AC 120240V AC XT

1756-PBXT ControlLogix-XT DC power supply 24V DC 18hellip32V DC XT

34 Publication 1756-SG001P-EN-P - May 2011

Redundant Power Supplies

To build a redundant power supply system you need the following

Two redundant power supplies (both 1756-PA75R or 1756-PB75R) One 1756-PSCA2 chassis adapter module Two 1756-CPR2 cables to connect the power supplies to the

1756-PSCA2 chassis adapter module (091 m (3 ft) length) User-supplied annunciator wiring to connect the power supplies to the

input modules as needed

The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Accessories - Redundant Power Supplies

Visualization Products Visualization products together with Logix for control and NetLinx architecture for communication make up the Rockwell Automation Integrated Architecture strategy The visualization strategy combines Rockwell Automation expertise in Allen-Bradley electronic operator interface and industrialized personal computer hardware with Rockwell Software supervisory control software Current visualization products include the following

FactoryTalk View software PanelView Plus operator interface PanelView Plus CE operator interface Industrial computers and monitors

For more information see the Operator Interface catalog pages at httpwwwabcomenepubcatalogs1276221813761239781

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA75R ControlLogix redundant 120V220V AC 85hellip265V AC Standard series B

1756-PB75R 24V DC 192hellip32V DC Standard series B

Cat No Description Specifications

1756-PSCA2 Chassis adapter module Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Mounts directly to left side of 1756 chassis

1756-CPR2 Chassis adapter cable Connects redundant power supply to 1756-PCSA2 chassis adapter Length091 m (3 ft)

Publication 1756-SG001P-EN-P - May 2011 35

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU ltFEFF00560065007200770065006e00640065006e0020005300690065002000640069006500730065002000450069006e007300740065006c006c0075006e00670065006e0020007a0075006d002000450072007300740065006c006c0065006e00200076006f006e002000410064006f006200650020005000440046002d0044006f006b0075006d0065006e00740065006e002c00200076006f006e002000640065006e0065006e002000530069006500200068006f00630068007700650072007400690067006500200044007200750063006b006500200061007500660020004400650073006b0074006f0070002d0044007200750063006b00650072006e00200075006e0064002000500072006f006f0066002d00470065007200e400740065006e002000650072007a0065007500670065006e0020006d00f60063006800740065006e002e002000450072007300740065006c006c007400650020005000440046002d0044006f006b0075006d0065006e007400650020006b00f6006e006e0065006e0020006d006900740020004100630072006f00620061007400200075006e0064002000410064006f00620065002000520065006100640065007200200035002e00300020006f0064006500720020006800f600680065007200200067006500f600660066006e00650074002000770065007200640065006e002egt ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

Example Configuration - DeviceNet Network

Accessories - DeviceNet Network

PLC-51771-SDN ControlLogix

1756-DNB

Ultra3000

PanelView Plus1784-U2DN

Ultra5000

IO

Motor starter

PowerFlex AC

Sensor Pushbuttons

LightsBar Code Scanner

Cat No Description

KwikLink Lite flat media KwikLink Lite flat media is a newer ODVA-approved solution for wiring DeviceNet networks Drop-lines for connecting nodes are added by using the KwikLink Lite two-piece connectors This cable system supports the intermixing of DeviceNet cable types (thin-round with flat) All of the KwikLink Lite connectors provide insulation displacement technology with reduced assembly time

KwikLink flat media The KwikLink flat media system provides a modular cabling method with its flat 4-wire cable and insulation displacement connectors (IDCs) The KwikLink system allows nodes to be added to the network without severing the trunkline Cutting or stripping of the trunkline is eliminated as is the need for predetermined cable lengths

Round media Round trunk cable is available in bulk spools or as pre-molded cordsets or patchcords in varying lengths A wide variety of rugged durable DeviceNet components is available for use in round trunk systems Stainless steel versions of round cable system components are also available Thick-trunk round media systems use thick cable for maximum DeviceNet trunk line length Round media thin-trunk systems use thin cable to reduce maximum trunk line distances with a more

compact and cost-effective installation for some applications Thin-cable outer jacket material is TPE for additional chemical resistance

22 Publication 1756-SG001P-EN-P - May 2011

Data Highway Plus and Remote IO Communication Modules

The Data Highway Plus network supports messaging between devices The remote IO link connects to remote IO chassis and other intelligent devices

The 1756-DHRIO module supports messaging between devices on DH+ networks The remote IO functionality enables the module to act as a scanner for transferring digital and block-transfer data to and from remote IO devices

The 1756-RIO module can act as a scanner or adapter on a remote IO network In addition to digital and block-transfer data the 1756-RIO module transfers analog and specialty data without message instructions

Cat No Description Communication Rate DH+ Connections RIO Connections Maximum Recommended Logix Connections

1756-DHRIO Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

1756-RIO Remote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

mdash Remote IO scanner or adapter32 physical racks (076) any combination of rack size and block transfers

10 scheduled IO

1756-DHRIOXT ControlLogix-XT extended temperature Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

Publication 1756-SG001P-EN-P - May 2011 23

Example Configuration - DH+ Network

Example Configuration - Remote IO Network

Accessories - DH+ and Remote IO Networks

PanelView Plus

PLC-5 1784-U2DHPRSLogix 5000

ControlLogix1756-DHRIO

SLC 504

PanelView PlusPLC-5

1791 IO1794 IO

1756-RIO as a Remote IO Adapter

1756-DHRIO as a Remote IO Scanner

Cat No Description Specifications

1770-CD Cable to connect communication module to DH+ network Belden 9463 twinaxial

9300-RADKIT Remote access dial-in kit 56 Kbps modem connection to devices on a DH+ network includes pre-configured modem communication module DIN rail mounting hardware associated cables

24 Publication 1756-SG001P-EN-P - May 2011

FOUNDATION Fieldbus Linking Devices

The FOUNDATION Fieldbus protocol is a network designed for distributed control of process applications

Example Configuration - Bridge to EtherNetIP Network

Cat No Description Communication Rate Number of H1 Ports

Devices per H1 Link

Devices per Linking Device

1757FFLD2 FOUNDATION Fieldbus bridge to an Ethernet network

FOUNDATION Fieldbus 3125 KbpsEtherNetIP 10100 Mbps

2 16(8hellip10 recommended)

32

1757-FFLD4 4 64

1757-FFLDC2 FOUNDATION Fieldbus bridge to a ControlNet network

FOUNDATION Fieldbus 3125 KbpsControlNet 5 Mbps

2 16(8hellip10 recommended)

32

1757-FFLDC4 4 64

FactoryTalk View SERSFieldbusRSLogix 5000

1757-FFLD4

H1(1)

H1(2)H1(3)H1(4)

HSEIP

Publication 1756-SG001P-EN-P - May 2011 25

Example Configuration - Bridge to ControlNet Network

Other Connectivity Options

ControlLogix RedundancyFactoryTalk View SERSFieldbusRSLogix 5000

ControlNet Redundant Media

1757-FFLDC2

FF H1

EtherNetIP

Option Consideration

USB connection The 1756-L7x controller has a USB port in place of the serial port If your application requires RS-232 functionality see the many Encompass partners at httpwwwrockwellautomationcomencompass

Serial connection The serial port on the 1756-L6x controller is compatible with RS-232 serial communication The serial port supports the DF1 protocol to communicate with other devices on the serial linkTo use Logix5000 controllers on Modbus you connect through the serial port and execute a specific ladder logic routine The controller project is available with RSLogix 5000 Enterprise programming software For more information see Using Logix5000 Controllers as Masters or Slaves on Modbus Application Solution publication CIG-AP129

DH-485 network The controller serial port is compatible with DH-485 communication The DH-485 connection does support remote programming and monitoring via RSLogix 5000 softwareOr add a DH-485 communication bridge module (cat no 1756-DH485)

SynchLink network The SynchLink communication module (1756-SYNCH) provides time synchronization and data broadcasting capabilities for distributed motion and coordinated drive control The module connects a ControlLogix chassis to a SynchLink fiber-optic communication link

26 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Controllers The ControlLogix controller provides a scalable controller solution that is capable of addressing a large amount of IO points

The controller can be placed into any slot of a ControlLogix chassis and multiple controllers can be installed in the same chassis Multiple controllers in the same chassis communicate with each other over the backplane (just as controllers can communicate over networks) but operate independently

ControlLogix controllers can monitor and control IO across the ControlLogix backplane as well as over IO links ControlLogix controllers can communicate over EtherNetIP ControlNet DeviceNet DH+ Remote IO and RS-232-C (DF1DH-485 protocol) networks and many third party process and device networks To provide communication for a ControlLogix controller install the appropriate communication interface module into the chassis

For detailed specifications see 1756 ControlLogix Controllers Specifications publication 1756-TD001

Cat No Description User Memory

1756-L72 ControlLogix controller 1 built-in USB port 4 MB

1756-L73 8 MB

1756-L74 16 MB

1756-L75 32 MB

1756-L61 ControlLogix controller 1 built-in RS-232 port 2 MB

1756-L62 4 MB

1756-L63 8 MB

1756-L64 16 MB

1756-L65 32 MB

1756-L61S GuardLogix safety controller 2 MB standard1 MB safety

1756-L62S 4 MB standard1 MB safety

1756-L63S 8 MB standard375 MB safety

1756-LSP GuardLogix safety partner (one is required for each GuardLogix controller) mdash

1756-L63XT ControlLogix-XT controller extreme environment 8 MB

IMPORTANT Scan time for a project loaded in a 1756-L64 or 1756-L65 controller may be slower than for the same project loaded in one of the other 1756-L6x controllers See the Logix5000 Controllers Instruction Execution Time and Memory Use Reference Manual publication 1756-RM087 for instruction execution times

Publication 1756-SG001P-EN-P - May 2011 27

Standard ControlLogix Controllers

The ControlLogix controller is part of the Logix5000 family of controllers A ControlLogix system includes the following

The ControlLogix controller available in different combinations of user memory

RSLogix 5000 programming software 1756 ControlLogix IO modules that reside in a 1756 chassis Separate communication modules for network communication

Features - Standard ControlLogix Controllers

Feature 1756-L61 1756-L62 1756-L63 1756-L64 1756-L65

1756-L72 1756-L73 1756-L74 1756-L75

Controller tasks 32 tasks 100 programstask Event tasks all event triggers

Built-in communication ports 1 port RS-232 serial 1 port USB

Communication options EtherNetIP ControlNet DeviceNet Data Highway Plus Remote IO SynchLink Third-party process and device networks

Built-in port Serial USB

Controller connections supported max 250 500

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Full support

Integrated motion EtherNetIP connection SERCOS interface Analog options (encoder input LDT input SSI input)

Programming languages Relay ladder Structured text Function block SFC

28 Publication 1756-SG001P-EN-P - May 2011

GuardLogix Controllers

A GuardLogix controller is a ControlLogix controller that also provides safety control The GuardLogix system is a dual controller solutionmdashyou must use a 1756-L6xS primary controller and a 1756-LSP safety partner to achieve SIL 3CAT 4

During development safety and standard have the same rules multiple programmers online editing and forcing are all allowed Once the project is tested and ready for final validation you set the Safety Task to a SIL 3 integrity level which is then enforced by the GuardLogix controller When safety memory is locked and protected the safety logic cant be modified and all safety functions operate with SIL 3 integrity On the standard side of the GuardLogix controller all functions operate like a regular Logix controller

Use Guard IO modules for field device connectivity on Ethernet or DeviceNet networks and for safety interlocking between GuardLogix controllers use Ethernet or ControlNet networks Multiple GuardLogix controllers can share safety data for zone to zone interlocking or a single GuardLogix controller can use remote distributed safety IO between different cellsareas

In addition to the standard features of a ControlLogix controller the GuardLogix controller has these safety-related features

Application Description

SIL 1 2 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508 and applications up to and including PLeCat4 according to ISO 13849-1 For more information see GuardLogix Controllers Systems Safety Reference Manual publication 1756-RM093 GuardLogix Controllers User Manual publication 1756-UM020 GuardLogix Safety Application Instruction Set Reference Manual publication 1756-RM095

Features - GuardLogix Controllers

Feature 1756-L61S 1756-L62S 1756-L63S 1756-LSP

Safety communication options Standard and safety EtherNetIP ControlNet DeviceNet

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Not supported

Programming languages Relay ladder

Publication 1756-SG001P-EN-P - May 2011 29

ControlLogix-XT Controllers

The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh corrosive environments

When used with FLEX IO-XT products the ControlLogix-XT system can withstand temperatures range from -2070 C (-4158 F)

When used independently the ControlLogix-XT system can withstand temperature ranges from -2570 C (-13158 F)

Redundant ControlLogix Controllers

The ControlLogix controller supports controller redundancy In a redundant controller system you need these components

Two 1756 chassis each with the following the same ndash Number of slots

ndash Modules in the same slots

ndash Redundancy firmware revisions in each module

ndash Two additional ControlNet nodes outside the redundant chassis pair

You need one of these redundancy modules

One 1756-RM module per chassis that supports the followingndash Two 1756-L61 1756-L62 1761-L63 controllers or one 1756-L64

controller

ndash Maximum of seven communication modules which can be 1756-CN2 series B 1756-CN2R series B and 1756-EN2T modules

ndash One 1756-RMCx cable

One 1757-SRM module per chassis that supports the followingndash One 1756-L61 1756-L62 1756-L63 1756-L64 controller

ndash Maximum of seven communication modules which can be 1756-CNB series D or E 1756-CNBR series D or E 1756-ENBT and 1756-EWEB modules

ndash One 1757-SRCx cable

30 Publication 1756-SG001P-EN-P - May 2011

Accessories - Controllers

Memory Cards

Memory cards offer nonvolatile memory to permanently store a user program and tag data on a controller The 1756-L7x ControlLogix controller comes with 1784-SD1 Secure Digital (SD) card already installed The 1756-L6x controllers support optional CompactFlash cards that you purchase separately The memory card installs in a socket on the controller Through RSLogix 5000 software you can manually trigger the controller to save to or load from nonvolatile memory or configure the controller to load from nonvolatile memory on powerup

The GuardLogix controller does not support user program storage or retrieval by using a CompactFlash card

1756 Energy Storage Modules

Instead of a battery the 1756-L7x controller ships with a 1756-ESMCAP energy storage module (ESM) already installed

Attribute 1784-CF64 1784-CF128 1784-SD1 1784-SD2

Memory 64 MB 128 MB 1 GB 2 GB

Supported controllers 1756-L6x 1756-L7x

Weight approx 142 g (05 oz) 176 g (0062 oz)

Cat No Description

1756-ESMCAP Capacitor-based energy-storage module Comes with the controller

1756-EMNSE ESM without WallClockTime backup power Additionally you can use this ESM with a 1756-L73 (8 MB) or smaller memory-sized controller only

Use this ESM if your application requires that the installed ESM deplete its residual energy to 40 microJoule or less before transporting it into or out of your application

1756-ESMNRM Energy-storage module that secures the controller by preventing the USB connection and SD card useThis ESM provides your application an enhanced degree of security

Publication 1756-SG001P-EN-P - May 2011 31

1756 ControlLogix Batteries

Each 1756-L6x controller ships with a battery With a memory card installed the controller can be used without a battery If you do not use a battery current tag data will be at the state it was when the memory card was saved

ControlLogix Chassis The ControlLogix system is a modular system that requires a 1756 IO chassis Place any module into any slot The backplane provides a high-speed communication path between modules

All of the chassis are designed for horizontal-only back-panel mounting The chassis are available in these configurations

Standard chassis ControlLogix-XT chassis

For detailed specifications see 1756 ControlLogix Chassis Specifications Specifications publication 1756-TD006

Features - Chassis

Slot guides and snap-in retention for easy and secure module fit for any type of 1756 module

Direct mounting accommodates any 1756 power supply

Attribute 1756-BA1 1756-BA2 1756-BATM(1) 1756-BATA

Description Lithium battery (059 g) Lithium battery (059 g) Externally mounted battery assembly

Replacement lithium battery for 1756-BATM (5 g max lithium per each D cell contains 2 D cells)

ControlLogix controllers 1756-L61 1756-L62 1756-L63 series A

1756-L61 1756-L62 1756-L63 series B1756-L64 1756-L65

1756-L61 1756-L62 1756-L63 series A

1756-BATM battery module

GuardLogix controllers mdash 1756-L61S 1756-L62S 1756-L63S

mdash mdash

ControlLogix-XT controllers

mdash 1756-L63XT mdash mdash

(1) The 1756-BATM externally mounted battery assembly is highly recommended for use with all series A 1756-L6x controllers and provides longer battery life than the 1756-BA1 battery The 1756-BATM includes one 1756-BATA lithium battery assembly and a 1 m (328 ft) cable to connect housing to controller

32 Publication 1756-SG001P-EN-P - May 2011

Standard Chassis

The chassis backplane provides a high-speed communication path between modules and distributes power to each of the modules within the chassis

ControlLogix-XT Chassis

The ControlLogix-XT chassis support extreme temperature environments

Accessories - Chassis

Use a slot filler module to fill empty slots

Cat No Description Slots

1756-A4 ControlLogix standard chassis 4

1756-A7 7

1756-A10 10

1756-A13 13

1756-A17 17

Cat No Description Slots Temperature Range

1756-A4LXT ControlLogix-XT chassis 4 -2560 degC (-13140 degF)

1756-A5XT 5 -2570 degC (-13158 degF)

1756-A7LXT 7 -2560 degC (-13140 degF)

Cat No Description

1756-N2 Slot filler module for empty slots in standard ControlLogix chassis

1756-N2XT Slot filler module for empty slots in ControlLogix-XT chassis

Publication 1756-SG001P-EN-P - May 2011 33

ControlLogix Power Supplies

ControlLogix power supplies are used with the 1756 chassis to provide 12V 33V 5V and 24V DC power directly to the chassis backplane Select from these configurations

Standard power Redundant power ControlLogix-XT power

For detailed specifications see 1756 ControlLogix Power Supplies Specifications publication 1756-TD005

Standard Power Supplies

You mount a standard power supply directly on the left end of the chassis where it plugs directly into the backplane

ControlLogix-XT Power Supplies

The ControlLogix-XT power supplies support extreme temperature environments

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA72 ControlLogix standard AC 120V220V AC 85hellip265V AC Standard series A and series B

1756-PA75 120V220V AC 85hellip265V AC Standard series B

1756-PB72 ControlLogix standard DC 24V DC 18hellip32V DC Standard series A and series B

1756-PB75 24V DC 1832V DC Standard series B

1756-PC75 48V DC 30hellip60V DC Standard series B

1756-PH75 125V DC 90hellip143V DC Standard series B

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PAXT ControlLogix-XT AC power supply 85265V AC 120240V AC XT

1756-PBXT ControlLogix-XT DC power supply 24V DC 18hellip32V DC XT

34 Publication 1756-SG001P-EN-P - May 2011

Redundant Power Supplies

To build a redundant power supply system you need the following

Two redundant power supplies (both 1756-PA75R or 1756-PB75R) One 1756-PSCA2 chassis adapter module Two 1756-CPR2 cables to connect the power supplies to the

1756-PSCA2 chassis adapter module (091 m (3 ft) length) User-supplied annunciator wiring to connect the power supplies to the

input modules as needed

The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Accessories - Redundant Power Supplies

Visualization Products Visualization products together with Logix for control and NetLinx architecture for communication make up the Rockwell Automation Integrated Architecture strategy The visualization strategy combines Rockwell Automation expertise in Allen-Bradley electronic operator interface and industrialized personal computer hardware with Rockwell Software supervisory control software Current visualization products include the following

FactoryTalk View software PanelView Plus operator interface PanelView Plus CE operator interface Industrial computers and monitors

For more information see the Operator Interface catalog pages at httpwwwabcomenepubcatalogs1276221813761239781

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA75R ControlLogix redundant 120V220V AC 85hellip265V AC Standard series B

1756-PB75R 24V DC 192hellip32V DC Standard series B

Cat No Description Specifications

1756-PSCA2 Chassis adapter module Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Mounts directly to left side of 1756 chassis

1756-CPR2 Chassis adapter cable Connects redundant power supply to 1756-PCSA2 chassis adapter Length091 m (3 ft)

Publication 1756-SG001P-EN-P - May 2011 35

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN ltFEFF9ad854c18cea51fa529b7528002000410064006f0062006500200050004400460020658766f8306e4f5c6210306b4f7f75283057307e30593002537052376642306e753b8cea3092670059279650306b4fdd306430533068304c3067304d307e3059300230c730b930af30c830c330d730d730ea30f330bf3067306e53705237307e305f306f30d730eb30fc30d57528306b9069305730663044307e305930023053306e8a2d5b9a30674f5c62103055308c305f0020005000440046002030d530a130a430eb306f3001004100630072006f0062006100740020304a30883073002000410064006f00620065002000520065006100640065007200200035002e003000204ee5964d3067958b304f30533068304c3067304d307e30593002gt KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

Data Highway Plus and Remote IO Communication Modules

The Data Highway Plus network supports messaging between devices The remote IO link connects to remote IO chassis and other intelligent devices

The 1756-DHRIO module supports messaging between devices on DH+ networks The remote IO functionality enables the module to act as a scanner for transferring digital and block-transfer data to and from remote IO devices

The 1756-RIO module can act as a scanner or adapter on a remote IO network In addition to digital and block-transfer data the 1756-RIO module transfers analog and specialty data without message instructions

Cat No Description Communication Rate DH+ Connections RIO Connections Maximum Recommended Logix Connections

1756-DHRIO Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

1756-RIO Remote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

mdash Remote IO scanner or adapter32 physical racks (076) any combination of rack size and block transfers

10 scheduled IO

1756-DHRIOXT ControlLogix-XT extended temperature Data Highway PlusRemote IO communication module

576 Kbps 1152 Kbps 2304 Kbps

32 DH+ messages per DH+ module

Remote IO scanner only32 logical rack connections per remote IO channel16 block-transfer connections per remote IO channel

32

Publication 1756-SG001P-EN-P - May 2011 23

Example Configuration - DH+ Network

Example Configuration - Remote IO Network

Accessories - DH+ and Remote IO Networks

PanelView Plus

PLC-5 1784-U2DHPRSLogix 5000

ControlLogix1756-DHRIO

SLC 504

PanelView PlusPLC-5

1791 IO1794 IO

1756-RIO as a Remote IO Adapter

1756-DHRIO as a Remote IO Scanner

Cat No Description Specifications

1770-CD Cable to connect communication module to DH+ network Belden 9463 twinaxial

9300-RADKIT Remote access dial-in kit 56 Kbps modem connection to devices on a DH+ network includes pre-configured modem communication module DIN rail mounting hardware associated cables

24 Publication 1756-SG001P-EN-P - May 2011

FOUNDATION Fieldbus Linking Devices

The FOUNDATION Fieldbus protocol is a network designed for distributed control of process applications

Example Configuration - Bridge to EtherNetIP Network

Cat No Description Communication Rate Number of H1 Ports

Devices per H1 Link

Devices per Linking Device

1757FFLD2 FOUNDATION Fieldbus bridge to an Ethernet network

FOUNDATION Fieldbus 3125 KbpsEtherNetIP 10100 Mbps

2 16(8hellip10 recommended)

32

1757-FFLD4 4 64

1757-FFLDC2 FOUNDATION Fieldbus bridge to a ControlNet network

FOUNDATION Fieldbus 3125 KbpsControlNet 5 Mbps

2 16(8hellip10 recommended)

32

1757-FFLDC4 4 64

FactoryTalk View SERSFieldbusRSLogix 5000

1757-FFLD4

H1(1)

H1(2)H1(3)H1(4)

HSEIP

Publication 1756-SG001P-EN-P - May 2011 25

Example Configuration - Bridge to ControlNet Network

Other Connectivity Options

ControlLogix RedundancyFactoryTalk View SERSFieldbusRSLogix 5000

ControlNet Redundant Media

1757-FFLDC2

FF H1

EtherNetIP

Option Consideration

USB connection The 1756-L7x controller has a USB port in place of the serial port If your application requires RS-232 functionality see the many Encompass partners at httpwwwrockwellautomationcomencompass

Serial connection The serial port on the 1756-L6x controller is compatible with RS-232 serial communication The serial port supports the DF1 protocol to communicate with other devices on the serial linkTo use Logix5000 controllers on Modbus you connect through the serial port and execute a specific ladder logic routine The controller project is available with RSLogix 5000 Enterprise programming software For more information see Using Logix5000 Controllers as Masters or Slaves on Modbus Application Solution publication CIG-AP129

DH-485 network The controller serial port is compatible with DH-485 communication The DH-485 connection does support remote programming and monitoring via RSLogix 5000 softwareOr add a DH-485 communication bridge module (cat no 1756-DH485)

SynchLink network The SynchLink communication module (1756-SYNCH) provides time synchronization and data broadcasting capabilities for distributed motion and coordinated drive control The module connects a ControlLogix chassis to a SynchLink fiber-optic communication link

26 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Controllers The ControlLogix controller provides a scalable controller solution that is capable of addressing a large amount of IO points

The controller can be placed into any slot of a ControlLogix chassis and multiple controllers can be installed in the same chassis Multiple controllers in the same chassis communicate with each other over the backplane (just as controllers can communicate over networks) but operate independently

ControlLogix controllers can monitor and control IO across the ControlLogix backplane as well as over IO links ControlLogix controllers can communicate over EtherNetIP ControlNet DeviceNet DH+ Remote IO and RS-232-C (DF1DH-485 protocol) networks and many third party process and device networks To provide communication for a ControlLogix controller install the appropriate communication interface module into the chassis

For detailed specifications see 1756 ControlLogix Controllers Specifications publication 1756-TD001

Cat No Description User Memory

1756-L72 ControlLogix controller 1 built-in USB port 4 MB

1756-L73 8 MB

1756-L74 16 MB

1756-L75 32 MB

1756-L61 ControlLogix controller 1 built-in RS-232 port 2 MB

1756-L62 4 MB

1756-L63 8 MB

1756-L64 16 MB

1756-L65 32 MB

1756-L61S GuardLogix safety controller 2 MB standard1 MB safety

1756-L62S 4 MB standard1 MB safety

1756-L63S 8 MB standard375 MB safety

1756-LSP GuardLogix safety partner (one is required for each GuardLogix controller) mdash

1756-L63XT ControlLogix-XT controller extreme environment 8 MB

IMPORTANT Scan time for a project loaded in a 1756-L64 or 1756-L65 controller may be slower than for the same project loaded in one of the other 1756-L6x controllers See the Logix5000 Controllers Instruction Execution Time and Memory Use Reference Manual publication 1756-RM087 for instruction execution times

Publication 1756-SG001P-EN-P - May 2011 27

Standard ControlLogix Controllers

The ControlLogix controller is part of the Logix5000 family of controllers A ControlLogix system includes the following

The ControlLogix controller available in different combinations of user memory

RSLogix 5000 programming software 1756 ControlLogix IO modules that reside in a 1756 chassis Separate communication modules for network communication

Features - Standard ControlLogix Controllers

Feature 1756-L61 1756-L62 1756-L63 1756-L64 1756-L65

1756-L72 1756-L73 1756-L74 1756-L75

Controller tasks 32 tasks 100 programstask Event tasks all event triggers

Built-in communication ports 1 port RS-232 serial 1 port USB

Communication options EtherNetIP ControlNet DeviceNet Data Highway Plus Remote IO SynchLink Third-party process and device networks

Built-in port Serial USB

Controller connections supported max 250 500

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Full support

Integrated motion EtherNetIP connection SERCOS interface Analog options (encoder input LDT input SSI input)

Programming languages Relay ladder Structured text Function block SFC

28 Publication 1756-SG001P-EN-P - May 2011

GuardLogix Controllers

A GuardLogix controller is a ControlLogix controller that also provides safety control The GuardLogix system is a dual controller solutionmdashyou must use a 1756-L6xS primary controller and a 1756-LSP safety partner to achieve SIL 3CAT 4

During development safety and standard have the same rules multiple programmers online editing and forcing are all allowed Once the project is tested and ready for final validation you set the Safety Task to a SIL 3 integrity level which is then enforced by the GuardLogix controller When safety memory is locked and protected the safety logic cant be modified and all safety functions operate with SIL 3 integrity On the standard side of the GuardLogix controller all functions operate like a regular Logix controller

Use Guard IO modules for field device connectivity on Ethernet or DeviceNet networks and for safety interlocking between GuardLogix controllers use Ethernet or ControlNet networks Multiple GuardLogix controllers can share safety data for zone to zone interlocking or a single GuardLogix controller can use remote distributed safety IO between different cellsareas

In addition to the standard features of a ControlLogix controller the GuardLogix controller has these safety-related features

Application Description

SIL 1 2 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508 and applications up to and including PLeCat4 according to ISO 13849-1 For more information see GuardLogix Controllers Systems Safety Reference Manual publication 1756-RM093 GuardLogix Controllers User Manual publication 1756-UM020 GuardLogix Safety Application Instruction Set Reference Manual publication 1756-RM095

Features - GuardLogix Controllers

Feature 1756-L61S 1756-L62S 1756-L63S 1756-LSP

Safety communication options Standard and safety EtherNetIP ControlNet DeviceNet

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Not supported

Programming languages Relay ladder

Publication 1756-SG001P-EN-P - May 2011 29

ControlLogix-XT Controllers

The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh corrosive environments

When used with FLEX IO-XT products the ControlLogix-XT system can withstand temperatures range from -2070 C (-4158 F)

When used independently the ControlLogix-XT system can withstand temperature ranges from -2570 C (-13158 F)

Redundant ControlLogix Controllers

The ControlLogix controller supports controller redundancy In a redundant controller system you need these components

Two 1756 chassis each with the following the same ndash Number of slots

ndash Modules in the same slots

ndash Redundancy firmware revisions in each module

ndash Two additional ControlNet nodes outside the redundant chassis pair

You need one of these redundancy modules

One 1756-RM module per chassis that supports the followingndash Two 1756-L61 1756-L62 1761-L63 controllers or one 1756-L64

controller

ndash Maximum of seven communication modules which can be 1756-CN2 series B 1756-CN2R series B and 1756-EN2T modules

ndash One 1756-RMCx cable

One 1757-SRM module per chassis that supports the followingndash One 1756-L61 1756-L62 1756-L63 1756-L64 controller

ndash Maximum of seven communication modules which can be 1756-CNB series D or E 1756-CNBR series D or E 1756-ENBT and 1756-EWEB modules

ndash One 1757-SRCx cable

30 Publication 1756-SG001P-EN-P - May 2011

Accessories - Controllers

Memory Cards

Memory cards offer nonvolatile memory to permanently store a user program and tag data on a controller The 1756-L7x ControlLogix controller comes with 1784-SD1 Secure Digital (SD) card already installed The 1756-L6x controllers support optional CompactFlash cards that you purchase separately The memory card installs in a socket on the controller Through RSLogix 5000 software you can manually trigger the controller to save to or load from nonvolatile memory or configure the controller to load from nonvolatile memory on powerup

The GuardLogix controller does not support user program storage or retrieval by using a CompactFlash card

1756 Energy Storage Modules

Instead of a battery the 1756-L7x controller ships with a 1756-ESMCAP energy storage module (ESM) already installed

Attribute 1784-CF64 1784-CF128 1784-SD1 1784-SD2

Memory 64 MB 128 MB 1 GB 2 GB

Supported controllers 1756-L6x 1756-L7x

Weight approx 142 g (05 oz) 176 g (0062 oz)

Cat No Description

1756-ESMCAP Capacitor-based energy-storage module Comes with the controller

1756-EMNSE ESM without WallClockTime backup power Additionally you can use this ESM with a 1756-L73 (8 MB) or smaller memory-sized controller only

Use this ESM if your application requires that the installed ESM deplete its residual energy to 40 microJoule or less before transporting it into or out of your application

1756-ESMNRM Energy-storage module that secures the controller by preventing the USB connection and SD card useThis ESM provides your application an enhanced degree of security

Publication 1756-SG001P-EN-P - May 2011 31

1756 ControlLogix Batteries

Each 1756-L6x controller ships with a battery With a memory card installed the controller can be used without a battery If you do not use a battery current tag data will be at the state it was when the memory card was saved

ControlLogix Chassis The ControlLogix system is a modular system that requires a 1756 IO chassis Place any module into any slot The backplane provides a high-speed communication path between modules

All of the chassis are designed for horizontal-only back-panel mounting The chassis are available in these configurations

Standard chassis ControlLogix-XT chassis

For detailed specifications see 1756 ControlLogix Chassis Specifications Specifications publication 1756-TD006

Features - Chassis

Slot guides and snap-in retention for easy and secure module fit for any type of 1756 module

Direct mounting accommodates any 1756 power supply

Attribute 1756-BA1 1756-BA2 1756-BATM(1) 1756-BATA

Description Lithium battery (059 g) Lithium battery (059 g) Externally mounted battery assembly

Replacement lithium battery for 1756-BATM (5 g max lithium per each D cell contains 2 D cells)

ControlLogix controllers 1756-L61 1756-L62 1756-L63 series A

1756-L61 1756-L62 1756-L63 series B1756-L64 1756-L65

1756-L61 1756-L62 1756-L63 series A

1756-BATM battery module

GuardLogix controllers mdash 1756-L61S 1756-L62S 1756-L63S

mdash mdash

ControlLogix-XT controllers

mdash 1756-L63XT mdash mdash

(1) The 1756-BATM externally mounted battery assembly is highly recommended for use with all series A 1756-L6x controllers and provides longer battery life than the 1756-BA1 battery The 1756-BATM includes one 1756-BATA lithium battery assembly and a 1 m (328 ft) cable to connect housing to controller

32 Publication 1756-SG001P-EN-P - May 2011

Standard Chassis

The chassis backplane provides a high-speed communication path between modules and distributes power to each of the modules within the chassis

ControlLogix-XT Chassis

The ControlLogix-XT chassis support extreme temperature environments

Accessories - Chassis

Use a slot filler module to fill empty slots

Cat No Description Slots

1756-A4 ControlLogix standard chassis 4

1756-A7 7

1756-A10 10

1756-A13 13

1756-A17 17

Cat No Description Slots Temperature Range

1756-A4LXT ControlLogix-XT chassis 4 -2560 degC (-13140 degF)

1756-A5XT 5 -2570 degC (-13158 degF)

1756-A7LXT 7 -2560 degC (-13140 degF)

Cat No Description

1756-N2 Slot filler module for empty slots in standard ControlLogix chassis

1756-N2XT Slot filler module for empty slots in ControlLogix-XT chassis

Publication 1756-SG001P-EN-P - May 2011 33

ControlLogix Power Supplies

ControlLogix power supplies are used with the 1756 chassis to provide 12V 33V 5V and 24V DC power directly to the chassis backplane Select from these configurations

Standard power Redundant power ControlLogix-XT power

For detailed specifications see 1756 ControlLogix Power Supplies Specifications publication 1756-TD005

Standard Power Supplies

You mount a standard power supply directly on the left end of the chassis where it plugs directly into the backplane

ControlLogix-XT Power Supplies

The ControlLogix-XT power supplies support extreme temperature environments

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA72 ControlLogix standard AC 120V220V AC 85hellip265V AC Standard series A and series B

1756-PA75 120V220V AC 85hellip265V AC Standard series B

1756-PB72 ControlLogix standard DC 24V DC 18hellip32V DC Standard series A and series B

1756-PB75 24V DC 1832V DC Standard series B

1756-PC75 48V DC 30hellip60V DC Standard series B

1756-PH75 125V DC 90hellip143V DC Standard series B

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PAXT ControlLogix-XT AC power supply 85265V AC 120240V AC XT

1756-PBXT ControlLogix-XT DC power supply 24V DC 18hellip32V DC XT

34 Publication 1756-SG001P-EN-P - May 2011

Redundant Power Supplies

To build a redundant power supply system you need the following

Two redundant power supplies (both 1756-PA75R or 1756-PB75R) One 1756-PSCA2 chassis adapter module Two 1756-CPR2 cables to connect the power supplies to the

1756-PSCA2 chassis adapter module (091 m (3 ft) length) User-supplied annunciator wiring to connect the power supplies to the

input modules as needed

The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Accessories - Redundant Power Supplies

Visualization Products Visualization products together with Logix for control and NetLinx architecture for communication make up the Rockwell Automation Integrated Architecture strategy The visualization strategy combines Rockwell Automation expertise in Allen-Bradley electronic operator interface and industrialized personal computer hardware with Rockwell Software supervisory control software Current visualization products include the following

FactoryTalk View software PanelView Plus operator interface PanelView Plus CE operator interface Industrial computers and monitors

For more information see the Operator Interface catalog pages at httpwwwabcomenepubcatalogs1276221813761239781

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA75R ControlLogix redundant 120V220V AC 85hellip265V AC Standard series B

1756-PB75R 24V DC 192hellip32V DC Standard series B

Cat No Description Specifications

1756-PSCA2 Chassis adapter module Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Mounts directly to left side of 1756 chassis

1756-CPR2 Chassis adapter cable Connects redundant power supply to 1756-PCSA2 chassis adapter Length091 m (3 ft)

Publication 1756-SG001P-EN-P - May 2011 35

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

Example Configuration - DH+ Network

Example Configuration - Remote IO Network

Accessories - DH+ and Remote IO Networks

PanelView Plus

PLC-5 1784-U2DHPRSLogix 5000

ControlLogix1756-DHRIO

SLC 504

PanelView PlusPLC-5

1791 IO1794 IO

1756-RIO as a Remote IO Adapter

1756-DHRIO as a Remote IO Scanner

Cat No Description Specifications

1770-CD Cable to connect communication module to DH+ network Belden 9463 twinaxial

9300-RADKIT Remote access dial-in kit 56 Kbps modem connection to devices on a DH+ network includes pre-configured modem communication module DIN rail mounting hardware associated cables

24 Publication 1756-SG001P-EN-P - May 2011

FOUNDATION Fieldbus Linking Devices

The FOUNDATION Fieldbus protocol is a network designed for distributed control of process applications

Example Configuration - Bridge to EtherNetIP Network

Cat No Description Communication Rate Number of H1 Ports

Devices per H1 Link

Devices per Linking Device

1757FFLD2 FOUNDATION Fieldbus bridge to an Ethernet network

FOUNDATION Fieldbus 3125 KbpsEtherNetIP 10100 Mbps

2 16(8hellip10 recommended)

32

1757-FFLD4 4 64

1757-FFLDC2 FOUNDATION Fieldbus bridge to a ControlNet network

FOUNDATION Fieldbus 3125 KbpsControlNet 5 Mbps

2 16(8hellip10 recommended)

32

1757-FFLDC4 4 64

FactoryTalk View SERSFieldbusRSLogix 5000

1757-FFLD4

H1(1)

H1(2)H1(3)H1(4)

HSEIP

Publication 1756-SG001P-EN-P - May 2011 25

Example Configuration - Bridge to ControlNet Network

Other Connectivity Options

ControlLogix RedundancyFactoryTalk View SERSFieldbusRSLogix 5000

ControlNet Redundant Media

1757-FFLDC2

FF H1

EtherNetIP

Option Consideration

USB connection The 1756-L7x controller has a USB port in place of the serial port If your application requires RS-232 functionality see the many Encompass partners at httpwwwrockwellautomationcomencompass

Serial connection The serial port on the 1756-L6x controller is compatible with RS-232 serial communication The serial port supports the DF1 protocol to communicate with other devices on the serial linkTo use Logix5000 controllers on Modbus you connect through the serial port and execute a specific ladder logic routine The controller project is available with RSLogix 5000 Enterprise programming software For more information see Using Logix5000 Controllers as Masters or Slaves on Modbus Application Solution publication CIG-AP129

DH-485 network The controller serial port is compatible with DH-485 communication The DH-485 connection does support remote programming and monitoring via RSLogix 5000 softwareOr add a DH-485 communication bridge module (cat no 1756-DH485)

SynchLink network The SynchLink communication module (1756-SYNCH) provides time synchronization and data broadcasting capabilities for distributed motion and coordinated drive control The module connects a ControlLogix chassis to a SynchLink fiber-optic communication link

26 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Controllers The ControlLogix controller provides a scalable controller solution that is capable of addressing a large amount of IO points

The controller can be placed into any slot of a ControlLogix chassis and multiple controllers can be installed in the same chassis Multiple controllers in the same chassis communicate with each other over the backplane (just as controllers can communicate over networks) but operate independently

ControlLogix controllers can monitor and control IO across the ControlLogix backplane as well as over IO links ControlLogix controllers can communicate over EtherNetIP ControlNet DeviceNet DH+ Remote IO and RS-232-C (DF1DH-485 protocol) networks and many third party process and device networks To provide communication for a ControlLogix controller install the appropriate communication interface module into the chassis

For detailed specifications see 1756 ControlLogix Controllers Specifications publication 1756-TD001

Cat No Description User Memory

1756-L72 ControlLogix controller 1 built-in USB port 4 MB

1756-L73 8 MB

1756-L74 16 MB

1756-L75 32 MB

1756-L61 ControlLogix controller 1 built-in RS-232 port 2 MB

1756-L62 4 MB

1756-L63 8 MB

1756-L64 16 MB

1756-L65 32 MB

1756-L61S GuardLogix safety controller 2 MB standard1 MB safety

1756-L62S 4 MB standard1 MB safety

1756-L63S 8 MB standard375 MB safety

1756-LSP GuardLogix safety partner (one is required for each GuardLogix controller) mdash

1756-L63XT ControlLogix-XT controller extreme environment 8 MB

IMPORTANT Scan time for a project loaded in a 1756-L64 or 1756-L65 controller may be slower than for the same project loaded in one of the other 1756-L6x controllers See the Logix5000 Controllers Instruction Execution Time and Memory Use Reference Manual publication 1756-RM087 for instruction execution times

Publication 1756-SG001P-EN-P - May 2011 27

Standard ControlLogix Controllers

The ControlLogix controller is part of the Logix5000 family of controllers A ControlLogix system includes the following

The ControlLogix controller available in different combinations of user memory

RSLogix 5000 programming software 1756 ControlLogix IO modules that reside in a 1756 chassis Separate communication modules for network communication

Features - Standard ControlLogix Controllers

Feature 1756-L61 1756-L62 1756-L63 1756-L64 1756-L65

1756-L72 1756-L73 1756-L74 1756-L75

Controller tasks 32 tasks 100 programstask Event tasks all event triggers

Built-in communication ports 1 port RS-232 serial 1 port USB

Communication options EtherNetIP ControlNet DeviceNet Data Highway Plus Remote IO SynchLink Third-party process and device networks

Built-in port Serial USB

Controller connections supported max 250 500

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Full support

Integrated motion EtherNetIP connection SERCOS interface Analog options (encoder input LDT input SSI input)

Programming languages Relay ladder Structured text Function block SFC

28 Publication 1756-SG001P-EN-P - May 2011

GuardLogix Controllers

A GuardLogix controller is a ControlLogix controller that also provides safety control The GuardLogix system is a dual controller solutionmdashyou must use a 1756-L6xS primary controller and a 1756-LSP safety partner to achieve SIL 3CAT 4

During development safety and standard have the same rules multiple programmers online editing and forcing are all allowed Once the project is tested and ready for final validation you set the Safety Task to a SIL 3 integrity level which is then enforced by the GuardLogix controller When safety memory is locked and protected the safety logic cant be modified and all safety functions operate with SIL 3 integrity On the standard side of the GuardLogix controller all functions operate like a regular Logix controller

Use Guard IO modules for field device connectivity on Ethernet or DeviceNet networks and for safety interlocking between GuardLogix controllers use Ethernet or ControlNet networks Multiple GuardLogix controllers can share safety data for zone to zone interlocking or a single GuardLogix controller can use remote distributed safety IO between different cellsareas

In addition to the standard features of a ControlLogix controller the GuardLogix controller has these safety-related features

Application Description

SIL 1 2 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508 and applications up to and including PLeCat4 according to ISO 13849-1 For more information see GuardLogix Controllers Systems Safety Reference Manual publication 1756-RM093 GuardLogix Controllers User Manual publication 1756-UM020 GuardLogix Safety Application Instruction Set Reference Manual publication 1756-RM095

Features - GuardLogix Controllers

Feature 1756-L61S 1756-L62S 1756-L63S 1756-LSP

Safety communication options Standard and safety EtherNetIP ControlNet DeviceNet

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Not supported

Programming languages Relay ladder

Publication 1756-SG001P-EN-P - May 2011 29

ControlLogix-XT Controllers

The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh corrosive environments

When used with FLEX IO-XT products the ControlLogix-XT system can withstand temperatures range from -2070 C (-4158 F)

When used independently the ControlLogix-XT system can withstand temperature ranges from -2570 C (-13158 F)

Redundant ControlLogix Controllers

The ControlLogix controller supports controller redundancy In a redundant controller system you need these components

Two 1756 chassis each with the following the same ndash Number of slots

ndash Modules in the same slots

ndash Redundancy firmware revisions in each module

ndash Two additional ControlNet nodes outside the redundant chassis pair

You need one of these redundancy modules

One 1756-RM module per chassis that supports the followingndash Two 1756-L61 1756-L62 1761-L63 controllers or one 1756-L64

controller

ndash Maximum of seven communication modules which can be 1756-CN2 series B 1756-CN2R series B and 1756-EN2T modules

ndash One 1756-RMCx cable

One 1757-SRM module per chassis that supports the followingndash One 1756-L61 1756-L62 1756-L63 1756-L64 controller

ndash Maximum of seven communication modules which can be 1756-CNB series D or E 1756-CNBR series D or E 1756-ENBT and 1756-EWEB modules

ndash One 1757-SRCx cable

30 Publication 1756-SG001P-EN-P - May 2011

Accessories - Controllers

Memory Cards

Memory cards offer nonvolatile memory to permanently store a user program and tag data on a controller The 1756-L7x ControlLogix controller comes with 1784-SD1 Secure Digital (SD) card already installed The 1756-L6x controllers support optional CompactFlash cards that you purchase separately The memory card installs in a socket on the controller Through RSLogix 5000 software you can manually trigger the controller to save to or load from nonvolatile memory or configure the controller to load from nonvolatile memory on powerup

The GuardLogix controller does not support user program storage or retrieval by using a CompactFlash card

1756 Energy Storage Modules

Instead of a battery the 1756-L7x controller ships with a 1756-ESMCAP energy storage module (ESM) already installed

Attribute 1784-CF64 1784-CF128 1784-SD1 1784-SD2

Memory 64 MB 128 MB 1 GB 2 GB

Supported controllers 1756-L6x 1756-L7x

Weight approx 142 g (05 oz) 176 g (0062 oz)

Cat No Description

1756-ESMCAP Capacitor-based energy-storage module Comes with the controller

1756-EMNSE ESM without WallClockTime backup power Additionally you can use this ESM with a 1756-L73 (8 MB) or smaller memory-sized controller only

Use this ESM if your application requires that the installed ESM deplete its residual energy to 40 microJoule or less before transporting it into or out of your application

1756-ESMNRM Energy-storage module that secures the controller by preventing the USB connection and SD card useThis ESM provides your application an enhanced degree of security

Publication 1756-SG001P-EN-P - May 2011 31

1756 ControlLogix Batteries

Each 1756-L6x controller ships with a battery With a memory card installed the controller can be used without a battery If you do not use a battery current tag data will be at the state it was when the memory card was saved

ControlLogix Chassis The ControlLogix system is a modular system that requires a 1756 IO chassis Place any module into any slot The backplane provides a high-speed communication path between modules

All of the chassis are designed for horizontal-only back-panel mounting The chassis are available in these configurations

Standard chassis ControlLogix-XT chassis

For detailed specifications see 1756 ControlLogix Chassis Specifications Specifications publication 1756-TD006

Features - Chassis

Slot guides and snap-in retention for easy and secure module fit for any type of 1756 module

Direct mounting accommodates any 1756 power supply

Attribute 1756-BA1 1756-BA2 1756-BATM(1) 1756-BATA

Description Lithium battery (059 g) Lithium battery (059 g) Externally mounted battery assembly

Replacement lithium battery for 1756-BATM (5 g max lithium per each D cell contains 2 D cells)

ControlLogix controllers 1756-L61 1756-L62 1756-L63 series A

1756-L61 1756-L62 1756-L63 series B1756-L64 1756-L65

1756-L61 1756-L62 1756-L63 series A

1756-BATM battery module

GuardLogix controllers mdash 1756-L61S 1756-L62S 1756-L63S

mdash mdash

ControlLogix-XT controllers

mdash 1756-L63XT mdash mdash

(1) The 1756-BATM externally mounted battery assembly is highly recommended for use with all series A 1756-L6x controllers and provides longer battery life than the 1756-BA1 battery The 1756-BATM includes one 1756-BATA lithium battery assembly and a 1 m (328 ft) cable to connect housing to controller

32 Publication 1756-SG001P-EN-P - May 2011

Standard Chassis

The chassis backplane provides a high-speed communication path between modules and distributes power to each of the modules within the chassis

ControlLogix-XT Chassis

The ControlLogix-XT chassis support extreme temperature environments

Accessories - Chassis

Use a slot filler module to fill empty slots

Cat No Description Slots

1756-A4 ControlLogix standard chassis 4

1756-A7 7

1756-A10 10

1756-A13 13

1756-A17 17

Cat No Description Slots Temperature Range

1756-A4LXT ControlLogix-XT chassis 4 -2560 degC (-13140 degF)

1756-A5XT 5 -2570 degC (-13158 degF)

1756-A7LXT 7 -2560 degC (-13140 degF)

Cat No Description

1756-N2 Slot filler module for empty slots in standard ControlLogix chassis

1756-N2XT Slot filler module for empty slots in ControlLogix-XT chassis

Publication 1756-SG001P-EN-P - May 2011 33

ControlLogix Power Supplies

ControlLogix power supplies are used with the 1756 chassis to provide 12V 33V 5V and 24V DC power directly to the chassis backplane Select from these configurations

Standard power Redundant power ControlLogix-XT power

For detailed specifications see 1756 ControlLogix Power Supplies Specifications publication 1756-TD005

Standard Power Supplies

You mount a standard power supply directly on the left end of the chassis where it plugs directly into the backplane

ControlLogix-XT Power Supplies

The ControlLogix-XT power supplies support extreme temperature environments

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA72 ControlLogix standard AC 120V220V AC 85hellip265V AC Standard series A and series B

1756-PA75 120V220V AC 85hellip265V AC Standard series B

1756-PB72 ControlLogix standard DC 24V DC 18hellip32V DC Standard series A and series B

1756-PB75 24V DC 1832V DC Standard series B

1756-PC75 48V DC 30hellip60V DC Standard series B

1756-PH75 125V DC 90hellip143V DC Standard series B

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PAXT ControlLogix-XT AC power supply 85265V AC 120240V AC XT

1756-PBXT ControlLogix-XT DC power supply 24V DC 18hellip32V DC XT

34 Publication 1756-SG001P-EN-P - May 2011

Redundant Power Supplies

To build a redundant power supply system you need the following

Two redundant power supplies (both 1756-PA75R or 1756-PB75R) One 1756-PSCA2 chassis adapter module Two 1756-CPR2 cables to connect the power supplies to the

1756-PSCA2 chassis adapter module (091 m (3 ft) length) User-supplied annunciator wiring to connect the power supplies to the

input modules as needed

The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Accessories - Redundant Power Supplies

Visualization Products Visualization products together with Logix for control and NetLinx architecture for communication make up the Rockwell Automation Integrated Architecture strategy The visualization strategy combines Rockwell Automation expertise in Allen-Bradley electronic operator interface and industrialized personal computer hardware with Rockwell Software supervisory control software Current visualization products include the following

FactoryTalk View software PanelView Plus operator interface PanelView Plus CE operator interface Industrial computers and monitors

For more information see the Operator Interface catalog pages at httpwwwabcomenepubcatalogs1276221813761239781

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA75R ControlLogix redundant 120V220V AC 85hellip265V AC Standard series B

1756-PB75R 24V DC 192hellip32V DC Standard series B

Cat No Description Specifications

1756-PSCA2 Chassis adapter module Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Mounts directly to left side of 1756 chassis

1756-CPR2 Chassis adapter cable Connects redundant power supply to 1756-PCSA2 chassis adapter Length091 m (3 ft)

Publication 1756-SG001P-EN-P - May 2011 35

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA ltFEFF005500740069006c006900730065007a00200063006500730020006f007000740069006f006e00730020006100660069006e00200064006500200063007200e900650072002000640065007300200064006f00630075006d0065006e00740073002000410064006f00620065002000500044004600200070006f007500720020006400650073002000e90070007200650075007600650073002000650074002000640065007300200069006d007000720065007300730069006f006e00730020006400650020006800610075007400650020007100750061006c0069007400e90020007300750072002000640065007300200069006d007000720069006d0061006e0074006500730020006400650020006200750072006500610075002e0020004c0065007300200064006f00630075006d0065006e00740073002000500044004600200063007200e900e90073002000700065007500760065006e0074002000ea0074007200650020006f007500760065007200740073002000640061006e00730020004100630072006f006200610074002c002000610069006e00730069002000710075002700410064006f00620065002000520065006100640065007200200035002e0030002000650074002000760065007200730069006f006e007300200075006c007400e90072006900650075007200650073002egt ITA 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 JPN ltFEFF9ad854c18cea51fa529b7528002000410064006f0062006500200050004400460020658766f8306e4f5c6210306b4f7f75283057307e30593002537052376642306e753b8cea3092670059279650306b4fdd306430533068304c3067304d307e3059300230c730b930af30c830c330d730d730ea30f330bf3067306e53705237307e305f306f30d730eb30fc30d57528306b9069305730663044307e305930023053306e8a2d5b9a30674f5c62103055308c305f0020005000440046002030d530a130a430eb306f3001004100630072006f0062006100740020304a30883073002000410064006f00620065002000520065006100640065007200200035002e003000204ee5964d3067958b304f30533068304c3067304d307e30593002gt KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB ltFEFF005500740069006c0069007a006500200065007300730061007300200063006f006e00660069006700750072006100e700f50065007300200064006500200066006f0072006d00610020006100200063007200690061007200200064006f00630075006d0065006e0074006f0073002000410064006f0062006500200050004400460020007000610072006100200069006d0070007200650073007300f5006500730020006400650020007100750061006c0069006400610064006500200065006d00200069006d00700072006500730073006f0072006100730020006400650073006b0074006f00700020006500200064006900730070006f00730069007400690076006f0073002000640065002000700072006f00760061002e0020004f007300200064006f00630075006d0065006e0074006f00730020005000440046002000630072006900610064006f007300200070006f00640065006d0020007300650072002000610062006500720074006f007300200063006f006d0020006f0020004100630072006f006200610074002000650020006f002000410064006f00620065002000520065006100640065007200200035002e0030002000650020007600650072007300f50065007300200070006f00730074006500720069006f007200650073002egt SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

FOUNDATION Fieldbus Linking Devices

The FOUNDATION Fieldbus protocol is a network designed for distributed control of process applications

Example Configuration - Bridge to EtherNetIP Network

Cat No Description Communication Rate Number of H1 Ports

Devices per H1 Link

Devices per Linking Device

1757FFLD2 FOUNDATION Fieldbus bridge to an Ethernet network

FOUNDATION Fieldbus 3125 KbpsEtherNetIP 10100 Mbps

2 16(8hellip10 recommended)

32

1757-FFLD4 4 64

1757-FFLDC2 FOUNDATION Fieldbus bridge to a ControlNet network

FOUNDATION Fieldbus 3125 KbpsControlNet 5 Mbps

2 16(8hellip10 recommended)

32

1757-FFLDC4 4 64

FactoryTalk View SERSFieldbusRSLogix 5000

1757-FFLD4

H1(1)

H1(2)H1(3)H1(4)

HSEIP

Publication 1756-SG001P-EN-P - May 2011 25

Example Configuration - Bridge to ControlNet Network

Other Connectivity Options

ControlLogix RedundancyFactoryTalk View SERSFieldbusRSLogix 5000

ControlNet Redundant Media

1757-FFLDC2

FF H1

EtherNetIP

Option Consideration

USB connection The 1756-L7x controller has a USB port in place of the serial port If your application requires RS-232 functionality see the many Encompass partners at httpwwwrockwellautomationcomencompass

Serial connection The serial port on the 1756-L6x controller is compatible with RS-232 serial communication The serial port supports the DF1 protocol to communicate with other devices on the serial linkTo use Logix5000 controllers on Modbus you connect through the serial port and execute a specific ladder logic routine The controller project is available with RSLogix 5000 Enterprise programming software For more information see Using Logix5000 Controllers as Masters or Slaves on Modbus Application Solution publication CIG-AP129

DH-485 network The controller serial port is compatible with DH-485 communication The DH-485 connection does support remote programming and monitoring via RSLogix 5000 softwareOr add a DH-485 communication bridge module (cat no 1756-DH485)

SynchLink network The SynchLink communication module (1756-SYNCH) provides time synchronization and data broadcasting capabilities for distributed motion and coordinated drive control The module connects a ControlLogix chassis to a SynchLink fiber-optic communication link

26 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Controllers The ControlLogix controller provides a scalable controller solution that is capable of addressing a large amount of IO points

The controller can be placed into any slot of a ControlLogix chassis and multiple controllers can be installed in the same chassis Multiple controllers in the same chassis communicate with each other over the backplane (just as controllers can communicate over networks) but operate independently

ControlLogix controllers can monitor and control IO across the ControlLogix backplane as well as over IO links ControlLogix controllers can communicate over EtherNetIP ControlNet DeviceNet DH+ Remote IO and RS-232-C (DF1DH-485 protocol) networks and many third party process and device networks To provide communication for a ControlLogix controller install the appropriate communication interface module into the chassis

For detailed specifications see 1756 ControlLogix Controllers Specifications publication 1756-TD001

Cat No Description User Memory

1756-L72 ControlLogix controller 1 built-in USB port 4 MB

1756-L73 8 MB

1756-L74 16 MB

1756-L75 32 MB

1756-L61 ControlLogix controller 1 built-in RS-232 port 2 MB

1756-L62 4 MB

1756-L63 8 MB

1756-L64 16 MB

1756-L65 32 MB

1756-L61S GuardLogix safety controller 2 MB standard1 MB safety

1756-L62S 4 MB standard1 MB safety

1756-L63S 8 MB standard375 MB safety

1756-LSP GuardLogix safety partner (one is required for each GuardLogix controller) mdash

1756-L63XT ControlLogix-XT controller extreme environment 8 MB

IMPORTANT Scan time for a project loaded in a 1756-L64 or 1756-L65 controller may be slower than for the same project loaded in one of the other 1756-L6x controllers See the Logix5000 Controllers Instruction Execution Time and Memory Use Reference Manual publication 1756-RM087 for instruction execution times

Publication 1756-SG001P-EN-P - May 2011 27

Standard ControlLogix Controllers

The ControlLogix controller is part of the Logix5000 family of controllers A ControlLogix system includes the following

The ControlLogix controller available in different combinations of user memory

RSLogix 5000 programming software 1756 ControlLogix IO modules that reside in a 1756 chassis Separate communication modules for network communication

Features - Standard ControlLogix Controllers

Feature 1756-L61 1756-L62 1756-L63 1756-L64 1756-L65

1756-L72 1756-L73 1756-L74 1756-L75

Controller tasks 32 tasks 100 programstask Event tasks all event triggers

Built-in communication ports 1 port RS-232 serial 1 port USB

Communication options EtherNetIP ControlNet DeviceNet Data Highway Plus Remote IO SynchLink Third-party process and device networks

Built-in port Serial USB

Controller connections supported max 250 500

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Full support

Integrated motion EtherNetIP connection SERCOS interface Analog options (encoder input LDT input SSI input)

Programming languages Relay ladder Structured text Function block SFC

28 Publication 1756-SG001P-EN-P - May 2011

GuardLogix Controllers

A GuardLogix controller is a ControlLogix controller that also provides safety control The GuardLogix system is a dual controller solutionmdashyou must use a 1756-L6xS primary controller and a 1756-LSP safety partner to achieve SIL 3CAT 4

During development safety and standard have the same rules multiple programmers online editing and forcing are all allowed Once the project is tested and ready for final validation you set the Safety Task to a SIL 3 integrity level which is then enforced by the GuardLogix controller When safety memory is locked and protected the safety logic cant be modified and all safety functions operate with SIL 3 integrity On the standard side of the GuardLogix controller all functions operate like a regular Logix controller

Use Guard IO modules for field device connectivity on Ethernet or DeviceNet networks and for safety interlocking between GuardLogix controllers use Ethernet or ControlNet networks Multiple GuardLogix controllers can share safety data for zone to zone interlocking or a single GuardLogix controller can use remote distributed safety IO between different cellsareas

In addition to the standard features of a ControlLogix controller the GuardLogix controller has these safety-related features

Application Description

SIL 1 2 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508 and applications up to and including PLeCat4 according to ISO 13849-1 For more information see GuardLogix Controllers Systems Safety Reference Manual publication 1756-RM093 GuardLogix Controllers User Manual publication 1756-UM020 GuardLogix Safety Application Instruction Set Reference Manual publication 1756-RM095

Features - GuardLogix Controllers

Feature 1756-L61S 1756-L62S 1756-L63S 1756-LSP

Safety communication options Standard and safety EtherNetIP ControlNet DeviceNet

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Not supported

Programming languages Relay ladder

Publication 1756-SG001P-EN-P - May 2011 29

ControlLogix-XT Controllers

The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh corrosive environments

When used with FLEX IO-XT products the ControlLogix-XT system can withstand temperatures range from -2070 C (-4158 F)

When used independently the ControlLogix-XT system can withstand temperature ranges from -2570 C (-13158 F)

Redundant ControlLogix Controllers

The ControlLogix controller supports controller redundancy In a redundant controller system you need these components

Two 1756 chassis each with the following the same ndash Number of slots

ndash Modules in the same slots

ndash Redundancy firmware revisions in each module

ndash Two additional ControlNet nodes outside the redundant chassis pair

You need one of these redundancy modules

One 1756-RM module per chassis that supports the followingndash Two 1756-L61 1756-L62 1761-L63 controllers or one 1756-L64

controller

ndash Maximum of seven communication modules which can be 1756-CN2 series B 1756-CN2R series B and 1756-EN2T modules

ndash One 1756-RMCx cable

One 1757-SRM module per chassis that supports the followingndash One 1756-L61 1756-L62 1756-L63 1756-L64 controller

ndash Maximum of seven communication modules which can be 1756-CNB series D or E 1756-CNBR series D or E 1756-ENBT and 1756-EWEB modules

ndash One 1757-SRCx cable

30 Publication 1756-SG001P-EN-P - May 2011

Accessories - Controllers

Memory Cards

Memory cards offer nonvolatile memory to permanently store a user program and tag data on a controller The 1756-L7x ControlLogix controller comes with 1784-SD1 Secure Digital (SD) card already installed The 1756-L6x controllers support optional CompactFlash cards that you purchase separately The memory card installs in a socket on the controller Through RSLogix 5000 software you can manually trigger the controller to save to or load from nonvolatile memory or configure the controller to load from nonvolatile memory on powerup

The GuardLogix controller does not support user program storage or retrieval by using a CompactFlash card

1756 Energy Storage Modules

Instead of a battery the 1756-L7x controller ships with a 1756-ESMCAP energy storage module (ESM) already installed

Attribute 1784-CF64 1784-CF128 1784-SD1 1784-SD2

Memory 64 MB 128 MB 1 GB 2 GB

Supported controllers 1756-L6x 1756-L7x

Weight approx 142 g (05 oz) 176 g (0062 oz)

Cat No Description

1756-ESMCAP Capacitor-based energy-storage module Comes with the controller

1756-EMNSE ESM without WallClockTime backup power Additionally you can use this ESM with a 1756-L73 (8 MB) or smaller memory-sized controller only

Use this ESM if your application requires that the installed ESM deplete its residual energy to 40 microJoule or less before transporting it into or out of your application

1756-ESMNRM Energy-storage module that secures the controller by preventing the USB connection and SD card useThis ESM provides your application an enhanced degree of security

Publication 1756-SG001P-EN-P - May 2011 31

1756 ControlLogix Batteries

Each 1756-L6x controller ships with a battery With a memory card installed the controller can be used without a battery If you do not use a battery current tag data will be at the state it was when the memory card was saved

ControlLogix Chassis The ControlLogix system is a modular system that requires a 1756 IO chassis Place any module into any slot The backplane provides a high-speed communication path between modules

All of the chassis are designed for horizontal-only back-panel mounting The chassis are available in these configurations

Standard chassis ControlLogix-XT chassis

For detailed specifications see 1756 ControlLogix Chassis Specifications Specifications publication 1756-TD006

Features - Chassis

Slot guides and snap-in retention for easy and secure module fit for any type of 1756 module

Direct mounting accommodates any 1756 power supply

Attribute 1756-BA1 1756-BA2 1756-BATM(1) 1756-BATA

Description Lithium battery (059 g) Lithium battery (059 g) Externally mounted battery assembly

Replacement lithium battery for 1756-BATM (5 g max lithium per each D cell contains 2 D cells)

ControlLogix controllers 1756-L61 1756-L62 1756-L63 series A

1756-L61 1756-L62 1756-L63 series B1756-L64 1756-L65

1756-L61 1756-L62 1756-L63 series A

1756-BATM battery module

GuardLogix controllers mdash 1756-L61S 1756-L62S 1756-L63S

mdash mdash

ControlLogix-XT controllers

mdash 1756-L63XT mdash mdash

(1) The 1756-BATM externally mounted battery assembly is highly recommended for use with all series A 1756-L6x controllers and provides longer battery life than the 1756-BA1 battery The 1756-BATM includes one 1756-BATA lithium battery assembly and a 1 m (328 ft) cable to connect housing to controller

32 Publication 1756-SG001P-EN-P - May 2011

Standard Chassis

The chassis backplane provides a high-speed communication path between modules and distributes power to each of the modules within the chassis

ControlLogix-XT Chassis

The ControlLogix-XT chassis support extreme temperature environments

Accessories - Chassis

Use a slot filler module to fill empty slots

Cat No Description Slots

1756-A4 ControlLogix standard chassis 4

1756-A7 7

1756-A10 10

1756-A13 13

1756-A17 17

Cat No Description Slots Temperature Range

1756-A4LXT ControlLogix-XT chassis 4 -2560 degC (-13140 degF)

1756-A5XT 5 -2570 degC (-13158 degF)

1756-A7LXT 7 -2560 degC (-13140 degF)

Cat No Description

1756-N2 Slot filler module for empty slots in standard ControlLogix chassis

1756-N2XT Slot filler module for empty slots in ControlLogix-XT chassis

Publication 1756-SG001P-EN-P - May 2011 33

ControlLogix Power Supplies

ControlLogix power supplies are used with the 1756 chassis to provide 12V 33V 5V and 24V DC power directly to the chassis backplane Select from these configurations

Standard power Redundant power ControlLogix-XT power

For detailed specifications see 1756 ControlLogix Power Supplies Specifications publication 1756-TD005

Standard Power Supplies

You mount a standard power supply directly on the left end of the chassis where it plugs directly into the backplane

ControlLogix-XT Power Supplies

The ControlLogix-XT power supplies support extreme temperature environments

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA72 ControlLogix standard AC 120V220V AC 85hellip265V AC Standard series A and series B

1756-PA75 120V220V AC 85hellip265V AC Standard series B

1756-PB72 ControlLogix standard DC 24V DC 18hellip32V DC Standard series A and series B

1756-PB75 24V DC 1832V DC Standard series B

1756-PC75 48V DC 30hellip60V DC Standard series B

1756-PH75 125V DC 90hellip143V DC Standard series B

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PAXT ControlLogix-XT AC power supply 85265V AC 120240V AC XT

1756-PBXT ControlLogix-XT DC power supply 24V DC 18hellip32V DC XT

34 Publication 1756-SG001P-EN-P - May 2011

Redundant Power Supplies

To build a redundant power supply system you need the following

Two redundant power supplies (both 1756-PA75R or 1756-PB75R) One 1756-PSCA2 chassis adapter module Two 1756-CPR2 cables to connect the power supplies to the

1756-PSCA2 chassis adapter module (091 m (3 ft) length) User-supplied annunciator wiring to connect the power supplies to the

input modules as needed

The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Accessories - Redundant Power Supplies

Visualization Products Visualization products together with Logix for control and NetLinx architecture for communication make up the Rockwell Automation Integrated Architecture strategy The visualization strategy combines Rockwell Automation expertise in Allen-Bradley electronic operator interface and industrialized personal computer hardware with Rockwell Software supervisory control software Current visualization products include the following

FactoryTalk View software PanelView Plus operator interface PanelView Plus CE operator interface Industrial computers and monitors

For more information see the Operator Interface catalog pages at httpwwwabcomenepubcatalogs1276221813761239781

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA75R ControlLogix redundant 120V220V AC 85hellip265V AC Standard series B

1756-PB75R 24V DC 192hellip32V DC Standard series B

Cat No Description Specifications

1756-PSCA2 Chassis adapter module Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Mounts directly to left side of 1756 chassis

1756-CPR2 Chassis adapter cable Connects redundant power supply to 1756-PCSA2 chassis adapter Length091 m (3 ft)

Publication 1756-SG001P-EN-P - May 2011 35

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

Example Configuration - Bridge to ControlNet Network

Other Connectivity Options

ControlLogix RedundancyFactoryTalk View SERSFieldbusRSLogix 5000

ControlNet Redundant Media

1757-FFLDC2

FF H1

EtherNetIP

Option Consideration

USB connection The 1756-L7x controller has a USB port in place of the serial port If your application requires RS-232 functionality see the many Encompass partners at httpwwwrockwellautomationcomencompass

Serial connection The serial port on the 1756-L6x controller is compatible with RS-232 serial communication The serial port supports the DF1 protocol to communicate with other devices on the serial linkTo use Logix5000 controllers on Modbus you connect through the serial port and execute a specific ladder logic routine The controller project is available with RSLogix 5000 Enterprise programming software For more information see Using Logix5000 Controllers as Masters or Slaves on Modbus Application Solution publication CIG-AP129

DH-485 network The controller serial port is compatible with DH-485 communication The DH-485 connection does support remote programming and monitoring via RSLogix 5000 softwareOr add a DH-485 communication bridge module (cat no 1756-DH485)

SynchLink network The SynchLink communication module (1756-SYNCH) provides time synchronization and data broadcasting capabilities for distributed motion and coordinated drive control The module connects a ControlLogix chassis to a SynchLink fiber-optic communication link

26 Publication 1756-SG001P-EN-P - May 2011

ControlLogix Controllers The ControlLogix controller provides a scalable controller solution that is capable of addressing a large amount of IO points

The controller can be placed into any slot of a ControlLogix chassis and multiple controllers can be installed in the same chassis Multiple controllers in the same chassis communicate with each other over the backplane (just as controllers can communicate over networks) but operate independently

ControlLogix controllers can monitor and control IO across the ControlLogix backplane as well as over IO links ControlLogix controllers can communicate over EtherNetIP ControlNet DeviceNet DH+ Remote IO and RS-232-C (DF1DH-485 protocol) networks and many third party process and device networks To provide communication for a ControlLogix controller install the appropriate communication interface module into the chassis

For detailed specifications see 1756 ControlLogix Controllers Specifications publication 1756-TD001

Cat No Description User Memory

1756-L72 ControlLogix controller 1 built-in USB port 4 MB

1756-L73 8 MB

1756-L74 16 MB

1756-L75 32 MB

1756-L61 ControlLogix controller 1 built-in RS-232 port 2 MB

1756-L62 4 MB

1756-L63 8 MB

1756-L64 16 MB

1756-L65 32 MB

1756-L61S GuardLogix safety controller 2 MB standard1 MB safety

1756-L62S 4 MB standard1 MB safety

1756-L63S 8 MB standard375 MB safety

1756-LSP GuardLogix safety partner (one is required for each GuardLogix controller) mdash

1756-L63XT ControlLogix-XT controller extreme environment 8 MB

IMPORTANT Scan time for a project loaded in a 1756-L64 or 1756-L65 controller may be slower than for the same project loaded in one of the other 1756-L6x controllers See the Logix5000 Controllers Instruction Execution Time and Memory Use Reference Manual publication 1756-RM087 for instruction execution times

Publication 1756-SG001P-EN-P - May 2011 27

Standard ControlLogix Controllers

The ControlLogix controller is part of the Logix5000 family of controllers A ControlLogix system includes the following

The ControlLogix controller available in different combinations of user memory

RSLogix 5000 programming software 1756 ControlLogix IO modules that reside in a 1756 chassis Separate communication modules for network communication

Features - Standard ControlLogix Controllers

Feature 1756-L61 1756-L62 1756-L63 1756-L64 1756-L65

1756-L72 1756-L73 1756-L74 1756-L75

Controller tasks 32 tasks 100 programstask Event tasks all event triggers

Built-in communication ports 1 port RS-232 serial 1 port USB

Communication options EtherNetIP ControlNet DeviceNet Data Highway Plus Remote IO SynchLink Third-party process and device networks

Built-in port Serial USB

Controller connections supported max 250 500

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Full support

Integrated motion EtherNetIP connection SERCOS interface Analog options (encoder input LDT input SSI input)

Programming languages Relay ladder Structured text Function block SFC

28 Publication 1756-SG001P-EN-P - May 2011

GuardLogix Controllers

A GuardLogix controller is a ControlLogix controller that also provides safety control The GuardLogix system is a dual controller solutionmdashyou must use a 1756-L6xS primary controller and a 1756-LSP safety partner to achieve SIL 3CAT 4

During development safety and standard have the same rules multiple programmers online editing and forcing are all allowed Once the project is tested and ready for final validation you set the Safety Task to a SIL 3 integrity level which is then enforced by the GuardLogix controller When safety memory is locked and protected the safety logic cant be modified and all safety functions operate with SIL 3 integrity On the standard side of the GuardLogix controller all functions operate like a regular Logix controller

Use Guard IO modules for field device connectivity on Ethernet or DeviceNet networks and for safety interlocking between GuardLogix controllers use Ethernet or ControlNet networks Multiple GuardLogix controllers can share safety data for zone to zone interlocking or a single GuardLogix controller can use remote distributed safety IO between different cellsareas

In addition to the standard features of a ControlLogix controller the GuardLogix controller has these safety-related features

Application Description

SIL 1 2 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508 and applications up to and including PLeCat4 according to ISO 13849-1 For more information see GuardLogix Controllers Systems Safety Reference Manual publication 1756-RM093 GuardLogix Controllers User Manual publication 1756-UM020 GuardLogix Safety Application Instruction Set Reference Manual publication 1756-RM095

Features - GuardLogix Controllers

Feature 1756-L61S 1756-L62S 1756-L63S 1756-LSP

Safety communication options Standard and safety EtherNetIP ControlNet DeviceNet

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Not supported

Programming languages Relay ladder

Publication 1756-SG001P-EN-P - May 2011 29

ControlLogix-XT Controllers

The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh corrosive environments

When used with FLEX IO-XT products the ControlLogix-XT system can withstand temperatures range from -2070 C (-4158 F)

When used independently the ControlLogix-XT system can withstand temperature ranges from -2570 C (-13158 F)

Redundant ControlLogix Controllers

The ControlLogix controller supports controller redundancy In a redundant controller system you need these components

Two 1756 chassis each with the following the same ndash Number of slots

ndash Modules in the same slots

ndash Redundancy firmware revisions in each module

ndash Two additional ControlNet nodes outside the redundant chassis pair

You need one of these redundancy modules

One 1756-RM module per chassis that supports the followingndash Two 1756-L61 1756-L62 1761-L63 controllers or one 1756-L64

controller

ndash Maximum of seven communication modules which can be 1756-CN2 series B 1756-CN2R series B and 1756-EN2T modules

ndash One 1756-RMCx cable

One 1757-SRM module per chassis that supports the followingndash One 1756-L61 1756-L62 1756-L63 1756-L64 controller

ndash Maximum of seven communication modules which can be 1756-CNB series D or E 1756-CNBR series D or E 1756-ENBT and 1756-EWEB modules

ndash One 1757-SRCx cable

30 Publication 1756-SG001P-EN-P - May 2011

Accessories - Controllers

Memory Cards

Memory cards offer nonvolatile memory to permanently store a user program and tag data on a controller The 1756-L7x ControlLogix controller comes with 1784-SD1 Secure Digital (SD) card already installed The 1756-L6x controllers support optional CompactFlash cards that you purchase separately The memory card installs in a socket on the controller Through RSLogix 5000 software you can manually trigger the controller to save to or load from nonvolatile memory or configure the controller to load from nonvolatile memory on powerup

The GuardLogix controller does not support user program storage or retrieval by using a CompactFlash card

1756 Energy Storage Modules

Instead of a battery the 1756-L7x controller ships with a 1756-ESMCAP energy storage module (ESM) already installed

Attribute 1784-CF64 1784-CF128 1784-SD1 1784-SD2

Memory 64 MB 128 MB 1 GB 2 GB

Supported controllers 1756-L6x 1756-L7x

Weight approx 142 g (05 oz) 176 g (0062 oz)

Cat No Description

1756-ESMCAP Capacitor-based energy-storage module Comes with the controller

1756-EMNSE ESM without WallClockTime backup power Additionally you can use this ESM with a 1756-L73 (8 MB) or smaller memory-sized controller only

Use this ESM if your application requires that the installed ESM deplete its residual energy to 40 microJoule or less before transporting it into or out of your application

1756-ESMNRM Energy-storage module that secures the controller by preventing the USB connection and SD card useThis ESM provides your application an enhanced degree of security

Publication 1756-SG001P-EN-P - May 2011 31

1756 ControlLogix Batteries

Each 1756-L6x controller ships with a battery With a memory card installed the controller can be used without a battery If you do not use a battery current tag data will be at the state it was when the memory card was saved

ControlLogix Chassis The ControlLogix system is a modular system that requires a 1756 IO chassis Place any module into any slot The backplane provides a high-speed communication path between modules

All of the chassis are designed for horizontal-only back-panel mounting The chassis are available in these configurations

Standard chassis ControlLogix-XT chassis

For detailed specifications see 1756 ControlLogix Chassis Specifications Specifications publication 1756-TD006

Features - Chassis

Slot guides and snap-in retention for easy and secure module fit for any type of 1756 module

Direct mounting accommodates any 1756 power supply

Attribute 1756-BA1 1756-BA2 1756-BATM(1) 1756-BATA

Description Lithium battery (059 g) Lithium battery (059 g) Externally mounted battery assembly

Replacement lithium battery for 1756-BATM (5 g max lithium per each D cell contains 2 D cells)

ControlLogix controllers 1756-L61 1756-L62 1756-L63 series A

1756-L61 1756-L62 1756-L63 series B1756-L64 1756-L65

1756-L61 1756-L62 1756-L63 series A

1756-BATM battery module

GuardLogix controllers mdash 1756-L61S 1756-L62S 1756-L63S

mdash mdash

ControlLogix-XT controllers

mdash 1756-L63XT mdash mdash

(1) The 1756-BATM externally mounted battery assembly is highly recommended for use with all series A 1756-L6x controllers and provides longer battery life than the 1756-BA1 battery The 1756-BATM includes one 1756-BATA lithium battery assembly and a 1 m (328 ft) cable to connect housing to controller

32 Publication 1756-SG001P-EN-P - May 2011

Standard Chassis

The chassis backplane provides a high-speed communication path between modules and distributes power to each of the modules within the chassis

ControlLogix-XT Chassis

The ControlLogix-XT chassis support extreme temperature environments

Accessories - Chassis

Use a slot filler module to fill empty slots

Cat No Description Slots

1756-A4 ControlLogix standard chassis 4

1756-A7 7

1756-A10 10

1756-A13 13

1756-A17 17

Cat No Description Slots Temperature Range

1756-A4LXT ControlLogix-XT chassis 4 -2560 degC (-13140 degF)

1756-A5XT 5 -2570 degC (-13158 degF)

1756-A7LXT 7 -2560 degC (-13140 degF)

Cat No Description

1756-N2 Slot filler module for empty slots in standard ControlLogix chassis

1756-N2XT Slot filler module for empty slots in ControlLogix-XT chassis

Publication 1756-SG001P-EN-P - May 2011 33

ControlLogix Power Supplies

ControlLogix power supplies are used with the 1756 chassis to provide 12V 33V 5V and 24V DC power directly to the chassis backplane Select from these configurations

Standard power Redundant power ControlLogix-XT power

For detailed specifications see 1756 ControlLogix Power Supplies Specifications publication 1756-TD005

Standard Power Supplies

You mount a standard power supply directly on the left end of the chassis where it plugs directly into the backplane

ControlLogix-XT Power Supplies

The ControlLogix-XT power supplies support extreme temperature environments

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA72 ControlLogix standard AC 120V220V AC 85hellip265V AC Standard series A and series B

1756-PA75 120V220V AC 85hellip265V AC Standard series B

1756-PB72 ControlLogix standard DC 24V DC 18hellip32V DC Standard series A and series B

1756-PB75 24V DC 1832V DC Standard series B

1756-PC75 48V DC 30hellip60V DC Standard series B

1756-PH75 125V DC 90hellip143V DC Standard series B

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PAXT ControlLogix-XT AC power supply 85265V AC 120240V AC XT

1756-PBXT ControlLogix-XT DC power supply 24V DC 18hellip32V DC XT

34 Publication 1756-SG001P-EN-P - May 2011

Redundant Power Supplies

To build a redundant power supply system you need the following

Two redundant power supplies (both 1756-PA75R or 1756-PB75R) One 1756-PSCA2 chassis adapter module Two 1756-CPR2 cables to connect the power supplies to the

1756-PSCA2 chassis adapter module (091 m (3 ft) length) User-supplied annunciator wiring to connect the power supplies to the

input modules as needed

The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Accessories - Redundant Power Supplies

Visualization Products Visualization products together with Logix for control and NetLinx architecture for communication make up the Rockwell Automation Integrated Architecture strategy The visualization strategy combines Rockwell Automation expertise in Allen-Bradley electronic operator interface and industrialized personal computer hardware with Rockwell Software supervisory control software Current visualization products include the following

FactoryTalk View software PanelView Plus operator interface PanelView Plus CE operator interface Industrial computers and monitors

For more information see the Operator Interface catalog pages at httpwwwabcomenepubcatalogs1276221813761239781

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA75R ControlLogix redundant 120V220V AC 85hellip265V AC Standard series B

1756-PB75R 24V DC 192hellip32V DC Standard series B

Cat No Description Specifications

1756-PSCA2 Chassis adapter module Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Mounts directly to left side of 1756 chassis

1756-CPR2 Chassis adapter cable Connects redundant power supply to 1756-PCSA2 chassis adapter Length091 m (3 ft)

Publication 1756-SG001P-EN-P - May 2011 35

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB ltFEFF005500740069006c0069007a006500200065007300730061007300200063006f006e00660069006700750072006100e700f50065007300200064006500200066006f0072006d00610020006100200063007200690061007200200064006f00630075006d0065006e0074006f0073002000410064006f0062006500200050004400460020007000610072006100200069006d0070007200650073007300f5006500730020006400650020007100750061006c0069006400610064006500200065006d00200069006d00700072006500730073006f0072006100730020006400650073006b0074006f00700020006500200064006900730070006f00730069007400690076006f0073002000640065002000700072006f00760061002e0020004f007300200064006f00630075006d0065006e0074006f00730020005000440046002000630072006900610064006f007300200070006f00640065006d0020007300650072002000610062006500720074006f007300200063006f006d0020006f0020004100630072006f006200610074002000650020006f002000410064006f00620065002000520065006100640065007200200035002e0030002000650020007600650072007300f50065007300200070006f00730074006500720069006f007200650073002egt SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

ControlLogix Controllers The ControlLogix controller provides a scalable controller solution that is capable of addressing a large amount of IO points

The controller can be placed into any slot of a ControlLogix chassis and multiple controllers can be installed in the same chassis Multiple controllers in the same chassis communicate with each other over the backplane (just as controllers can communicate over networks) but operate independently

ControlLogix controllers can monitor and control IO across the ControlLogix backplane as well as over IO links ControlLogix controllers can communicate over EtherNetIP ControlNet DeviceNet DH+ Remote IO and RS-232-C (DF1DH-485 protocol) networks and many third party process and device networks To provide communication for a ControlLogix controller install the appropriate communication interface module into the chassis

For detailed specifications see 1756 ControlLogix Controllers Specifications publication 1756-TD001

Cat No Description User Memory

1756-L72 ControlLogix controller 1 built-in USB port 4 MB

1756-L73 8 MB

1756-L74 16 MB

1756-L75 32 MB

1756-L61 ControlLogix controller 1 built-in RS-232 port 2 MB

1756-L62 4 MB

1756-L63 8 MB

1756-L64 16 MB

1756-L65 32 MB

1756-L61S GuardLogix safety controller 2 MB standard1 MB safety

1756-L62S 4 MB standard1 MB safety

1756-L63S 8 MB standard375 MB safety

1756-LSP GuardLogix safety partner (one is required for each GuardLogix controller) mdash

1756-L63XT ControlLogix-XT controller extreme environment 8 MB

IMPORTANT Scan time for a project loaded in a 1756-L64 or 1756-L65 controller may be slower than for the same project loaded in one of the other 1756-L6x controllers See the Logix5000 Controllers Instruction Execution Time and Memory Use Reference Manual publication 1756-RM087 for instruction execution times

Publication 1756-SG001P-EN-P - May 2011 27

Standard ControlLogix Controllers

The ControlLogix controller is part of the Logix5000 family of controllers A ControlLogix system includes the following

The ControlLogix controller available in different combinations of user memory

RSLogix 5000 programming software 1756 ControlLogix IO modules that reside in a 1756 chassis Separate communication modules for network communication

Features - Standard ControlLogix Controllers

Feature 1756-L61 1756-L62 1756-L63 1756-L64 1756-L65

1756-L72 1756-L73 1756-L74 1756-L75

Controller tasks 32 tasks 100 programstask Event tasks all event triggers

Built-in communication ports 1 port RS-232 serial 1 port USB

Communication options EtherNetIP ControlNet DeviceNet Data Highway Plus Remote IO SynchLink Third-party process and device networks

Built-in port Serial USB

Controller connections supported max 250 500

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Full support

Integrated motion EtherNetIP connection SERCOS interface Analog options (encoder input LDT input SSI input)

Programming languages Relay ladder Structured text Function block SFC

28 Publication 1756-SG001P-EN-P - May 2011

GuardLogix Controllers

A GuardLogix controller is a ControlLogix controller that also provides safety control The GuardLogix system is a dual controller solutionmdashyou must use a 1756-L6xS primary controller and a 1756-LSP safety partner to achieve SIL 3CAT 4

During development safety and standard have the same rules multiple programmers online editing and forcing are all allowed Once the project is tested and ready for final validation you set the Safety Task to a SIL 3 integrity level which is then enforced by the GuardLogix controller When safety memory is locked and protected the safety logic cant be modified and all safety functions operate with SIL 3 integrity On the standard side of the GuardLogix controller all functions operate like a regular Logix controller

Use Guard IO modules for field device connectivity on Ethernet or DeviceNet networks and for safety interlocking between GuardLogix controllers use Ethernet or ControlNet networks Multiple GuardLogix controllers can share safety data for zone to zone interlocking or a single GuardLogix controller can use remote distributed safety IO between different cellsareas

In addition to the standard features of a ControlLogix controller the GuardLogix controller has these safety-related features

Application Description

SIL 1 2 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508 and applications up to and including PLeCat4 according to ISO 13849-1 For more information see GuardLogix Controllers Systems Safety Reference Manual publication 1756-RM093 GuardLogix Controllers User Manual publication 1756-UM020 GuardLogix Safety Application Instruction Set Reference Manual publication 1756-RM095

Features - GuardLogix Controllers

Feature 1756-L61S 1756-L62S 1756-L63S 1756-LSP

Safety communication options Standard and safety EtherNetIP ControlNet DeviceNet

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Not supported

Programming languages Relay ladder

Publication 1756-SG001P-EN-P - May 2011 29

ControlLogix-XT Controllers

The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh corrosive environments

When used with FLEX IO-XT products the ControlLogix-XT system can withstand temperatures range from -2070 C (-4158 F)

When used independently the ControlLogix-XT system can withstand temperature ranges from -2570 C (-13158 F)

Redundant ControlLogix Controllers

The ControlLogix controller supports controller redundancy In a redundant controller system you need these components

Two 1756 chassis each with the following the same ndash Number of slots

ndash Modules in the same slots

ndash Redundancy firmware revisions in each module

ndash Two additional ControlNet nodes outside the redundant chassis pair

You need one of these redundancy modules

One 1756-RM module per chassis that supports the followingndash Two 1756-L61 1756-L62 1761-L63 controllers or one 1756-L64

controller

ndash Maximum of seven communication modules which can be 1756-CN2 series B 1756-CN2R series B and 1756-EN2T modules

ndash One 1756-RMCx cable

One 1757-SRM module per chassis that supports the followingndash One 1756-L61 1756-L62 1756-L63 1756-L64 controller

ndash Maximum of seven communication modules which can be 1756-CNB series D or E 1756-CNBR series D or E 1756-ENBT and 1756-EWEB modules

ndash One 1757-SRCx cable

30 Publication 1756-SG001P-EN-P - May 2011

Accessories - Controllers

Memory Cards

Memory cards offer nonvolatile memory to permanently store a user program and tag data on a controller The 1756-L7x ControlLogix controller comes with 1784-SD1 Secure Digital (SD) card already installed The 1756-L6x controllers support optional CompactFlash cards that you purchase separately The memory card installs in a socket on the controller Through RSLogix 5000 software you can manually trigger the controller to save to or load from nonvolatile memory or configure the controller to load from nonvolatile memory on powerup

The GuardLogix controller does not support user program storage or retrieval by using a CompactFlash card

1756 Energy Storage Modules

Instead of a battery the 1756-L7x controller ships with a 1756-ESMCAP energy storage module (ESM) already installed

Attribute 1784-CF64 1784-CF128 1784-SD1 1784-SD2

Memory 64 MB 128 MB 1 GB 2 GB

Supported controllers 1756-L6x 1756-L7x

Weight approx 142 g (05 oz) 176 g (0062 oz)

Cat No Description

1756-ESMCAP Capacitor-based energy-storage module Comes with the controller

1756-EMNSE ESM without WallClockTime backup power Additionally you can use this ESM with a 1756-L73 (8 MB) or smaller memory-sized controller only

Use this ESM if your application requires that the installed ESM deplete its residual energy to 40 microJoule or less before transporting it into or out of your application

1756-ESMNRM Energy-storage module that secures the controller by preventing the USB connection and SD card useThis ESM provides your application an enhanced degree of security

Publication 1756-SG001P-EN-P - May 2011 31

1756 ControlLogix Batteries

Each 1756-L6x controller ships with a battery With a memory card installed the controller can be used without a battery If you do not use a battery current tag data will be at the state it was when the memory card was saved

ControlLogix Chassis The ControlLogix system is a modular system that requires a 1756 IO chassis Place any module into any slot The backplane provides a high-speed communication path between modules

All of the chassis are designed for horizontal-only back-panel mounting The chassis are available in these configurations

Standard chassis ControlLogix-XT chassis

For detailed specifications see 1756 ControlLogix Chassis Specifications Specifications publication 1756-TD006

Features - Chassis

Slot guides and snap-in retention for easy and secure module fit for any type of 1756 module

Direct mounting accommodates any 1756 power supply

Attribute 1756-BA1 1756-BA2 1756-BATM(1) 1756-BATA

Description Lithium battery (059 g) Lithium battery (059 g) Externally mounted battery assembly

Replacement lithium battery for 1756-BATM (5 g max lithium per each D cell contains 2 D cells)

ControlLogix controllers 1756-L61 1756-L62 1756-L63 series A

1756-L61 1756-L62 1756-L63 series B1756-L64 1756-L65

1756-L61 1756-L62 1756-L63 series A

1756-BATM battery module

GuardLogix controllers mdash 1756-L61S 1756-L62S 1756-L63S

mdash mdash

ControlLogix-XT controllers

mdash 1756-L63XT mdash mdash

(1) The 1756-BATM externally mounted battery assembly is highly recommended for use with all series A 1756-L6x controllers and provides longer battery life than the 1756-BA1 battery The 1756-BATM includes one 1756-BATA lithium battery assembly and a 1 m (328 ft) cable to connect housing to controller

32 Publication 1756-SG001P-EN-P - May 2011

Standard Chassis

The chassis backplane provides a high-speed communication path between modules and distributes power to each of the modules within the chassis

ControlLogix-XT Chassis

The ControlLogix-XT chassis support extreme temperature environments

Accessories - Chassis

Use a slot filler module to fill empty slots

Cat No Description Slots

1756-A4 ControlLogix standard chassis 4

1756-A7 7

1756-A10 10

1756-A13 13

1756-A17 17

Cat No Description Slots Temperature Range

1756-A4LXT ControlLogix-XT chassis 4 -2560 degC (-13140 degF)

1756-A5XT 5 -2570 degC (-13158 degF)

1756-A7LXT 7 -2560 degC (-13140 degF)

Cat No Description

1756-N2 Slot filler module for empty slots in standard ControlLogix chassis

1756-N2XT Slot filler module for empty slots in ControlLogix-XT chassis

Publication 1756-SG001P-EN-P - May 2011 33

ControlLogix Power Supplies

ControlLogix power supplies are used with the 1756 chassis to provide 12V 33V 5V and 24V DC power directly to the chassis backplane Select from these configurations

Standard power Redundant power ControlLogix-XT power

For detailed specifications see 1756 ControlLogix Power Supplies Specifications publication 1756-TD005

Standard Power Supplies

You mount a standard power supply directly on the left end of the chassis where it plugs directly into the backplane

ControlLogix-XT Power Supplies

The ControlLogix-XT power supplies support extreme temperature environments

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA72 ControlLogix standard AC 120V220V AC 85hellip265V AC Standard series A and series B

1756-PA75 120V220V AC 85hellip265V AC Standard series B

1756-PB72 ControlLogix standard DC 24V DC 18hellip32V DC Standard series A and series B

1756-PB75 24V DC 1832V DC Standard series B

1756-PC75 48V DC 30hellip60V DC Standard series B

1756-PH75 125V DC 90hellip143V DC Standard series B

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PAXT ControlLogix-XT AC power supply 85265V AC 120240V AC XT

1756-PBXT ControlLogix-XT DC power supply 24V DC 18hellip32V DC XT

34 Publication 1756-SG001P-EN-P - May 2011

Redundant Power Supplies

To build a redundant power supply system you need the following

Two redundant power supplies (both 1756-PA75R or 1756-PB75R) One 1756-PSCA2 chassis adapter module Two 1756-CPR2 cables to connect the power supplies to the

1756-PSCA2 chassis adapter module (091 m (3 ft) length) User-supplied annunciator wiring to connect the power supplies to the

input modules as needed

The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Accessories - Redundant Power Supplies

Visualization Products Visualization products together with Logix for control and NetLinx architecture for communication make up the Rockwell Automation Integrated Architecture strategy The visualization strategy combines Rockwell Automation expertise in Allen-Bradley electronic operator interface and industrialized personal computer hardware with Rockwell Software supervisory control software Current visualization products include the following

FactoryTalk View software PanelView Plus operator interface PanelView Plus CE operator interface Industrial computers and monitors

For more information see the Operator Interface catalog pages at httpwwwabcomenepubcatalogs1276221813761239781

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA75R ControlLogix redundant 120V220V AC 85hellip265V AC Standard series B

1756-PB75R 24V DC 192hellip32V DC Standard series B

Cat No Description Specifications

1756-PSCA2 Chassis adapter module Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Mounts directly to left side of 1756 chassis

1756-CPR2 Chassis adapter cable Connects redundant power supply to 1756-PCSA2 chassis adapter Length091 m (3 ft)

Publication 1756-SG001P-EN-P - May 2011 35

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE ltFEFF0041006e007600e4006e00640020006400650020006800e4007200200069006e0073007400e4006c006c006e0069006e006700610072006e00610020006f006d002000640075002000760069006c006c00200073006b006100700061002000410064006f006200650020005000440046002d0064006f006b0075006d0065006e00740020006600f600720020006b00760061006c00690074006500740073007500740073006b0072006900660074006500720020007000e5002000760061006e006c00690067006100200073006b0072006900760061007200650020006f006300680020006600f600720020006b006f007200720065006b007400750072002e002000200053006b006100700061006400650020005000440046002d0064006f006b0075006d0065006e00740020006b0061006e002000f600700070006e00610073002000690020004100630072006f0062006100740020006f00630068002000410064006f00620065002000520065006100640065007200200035002e00300020006f00630068002000730065006e006100720065002egt ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

Standard ControlLogix Controllers

The ControlLogix controller is part of the Logix5000 family of controllers A ControlLogix system includes the following

The ControlLogix controller available in different combinations of user memory

RSLogix 5000 programming software 1756 ControlLogix IO modules that reside in a 1756 chassis Separate communication modules for network communication

Features - Standard ControlLogix Controllers

Feature 1756-L61 1756-L62 1756-L63 1756-L64 1756-L65

1756-L72 1756-L73 1756-L74 1756-L75

Controller tasks 32 tasks 100 programstask Event tasks all event triggers

Built-in communication ports 1 port RS-232 serial 1 port USB

Communication options EtherNetIP ControlNet DeviceNet Data Highway Plus Remote IO SynchLink Third-party process and device networks

Built-in port Serial USB

Controller connections supported max 250 500

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Full support

Integrated motion EtherNetIP connection SERCOS interface Analog options (encoder input LDT input SSI input)

Programming languages Relay ladder Structured text Function block SFC

28 Publication 1756-SG001P-EN-P - May 2011

GuardLogix Controllers

A GuardLogix controller is a ControlLogix controller that also provides safety control The GuardLogix system is a dual controller solutionmdashyou must use a 1756-L6xS primary controller and a 1756-LSP safety partner to achieve SIL 3CAT 4

During development safety and standard have the same rules multiple programmers online editing and forcing are all allowed Once the project is tested and ready for final validation you set the Safety Task to a SIL 3 integrity level which is then enforced by the GuardLogix controller When safety memory is locked and protected the safety logic cant be modified and all safety functions operate with SIL 3 integrity On the standard side of the GuardLogix controller all functions operate like a regular Logix controller

Use Guard IO modules for field device connectivity on Ethernet or DeviceNet networks and for safety interlocking between GuardLogix controllers use Ethernet or ControlNet networks Multiple GuardLogix controllers can share safety data for zone to zone interlocking or a single GuardLogix controller can use remote distributed safety IO between different cellsareas

In addition to the standard features of a ControlLogix controller the GuardLogix controller has these safety-related features

Application Description

SIL 1 2 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508 and applications up to and including PLeCat4 according to ISO 13849-1 For more information see GuardLogix Controllers Systems Safety Reference Manual publication 1756-RM093 GuardLogix Controllers User Manual publication 1756-UM020 GuardLogix Safety Application Instruction Set Reference Manual publication 1756-RM095

Features - GuardLogix Controllers

Feature 1756-L61S 1756-L62S 1756-L63S 1756-LSP

Safety communication options Standard and safety EtherNetIP ControlNet DeviceNet

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Not supported

Programming languages Relay ladder

Publication 1756-SG001P-EN-P - May 2011 29

ControlLogix-XT Controllers

The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh corrosive environments

When used with FLEX IO-XT products the ControlLogix-XT system can withstand temperatures range from -2070 C (-4158 F)

When used independently the ControlLogix-XT system can withstand temperature ranges from -2570 C (-13158 F)

Redundant ControlLogix Controllers

The ControlLogix controller supports controller redundancy In a redundant controller system you need these components

Two 1756 chassis each with the following the same ndash Number of slots

ndash Modules in the same slots

ndash Redundancy firmware revisions in each module

ndash Two additional ControlNet nodes outside the redundant chassis pair

You need one of these redundancy modules

One 1756-RM module per chassis that supports the followingndash Two 1756-L61 1756-L62 1761-L63 controllers or one 1756-L64

controller

ndash Maximum of seven communication modules which can be 1756-CN2 series B 1756-CN2R series B and 1756-EN2T modules

ndash One 1756-RMCx cable

One 1757-SRM module per chassis that supports the followingndash One 1756-L61 1756-L62 1756-L63 1756-L64 controller

ndash Maximum of seven communication modules which can be 1756-CNB series D or E 1756-CNBR series D or E 1756-ENBT and 1756-EWEB modules

ndash One 1757-SRCx cable

30 Publication 1756-SG001P-EN-P - May 2011

Accessories - Controllers

Memory Cards

Memory cards offer nonvolatile memory to permanently store a user program and tag data on a controller The 1756-L7x ControlLogix controller comes with 1784-SD1 Secure Digital (SD) card already installed The 1756-L6x controllers support optional CompactFlash cards that you purchase separately The memory card installs in a socket on the controller Through RSLogix 5000 software you can manually trigger the controller to save to or load from nonvolatile memory or configure the controller to load from nonvolatile memory on powerup

The GuardLogix controller does not support user program storage or retrieval by using a CompactFlash card

1756 Energy Storage Modules

Instead of a battery the 1756-L7x controller ships with a 1756-ESMCAP energy storage module (ESM) already installed

Attribute 1784-CF64 1784-CF128 1784-SD1 1784-SD2

Memory 64 MB 128 MB 1 GB 2 GB

Supported controllers 1756-L6x 1756-L7x

Weight approx 142 g (05 oz) 176 g (0062 oz)

Cat No Description

1756-ESMCAP Capacitor-based energy-storage module Comes with the controller

1756-EMNSE ESM without WallClockTime backup power Additionally you can use this ESM with a 1756-L73 (8 MB) or smaller memory-sized controller only

Use this ESM if your application requires that the installed ESM deplete its residual energy to 40 microJoule or less before transporting it into or out of your application

1756-ESMNRM Energy-storage module that secures the controller by preventing the USB connection and SD card useThis ESM provides your application an enhanced degree of security

Publication 1756-SG001P-EN-P - May 2011 31

1756 ControlLogix Batteries

Each 1756-L6x controller ships with a battery With a memory card installed the controller can be used without a battery If you do not use a battery current tag data will be at the state it was when the memory card was saved

ControlLogix Chassis The ControlLogix system is a modular system that requires a 1756 IO chassis Place any module into any slot The backplane provides a high-speed communication path between modules

All of the chassis are designed for horizontal-only back-panel mounting The chassis are available in these configurations

Standard chassis ControlLogix-XT chassis

For detailed specifications see 1756 ControlLogix Chassis Specifications Specifications publication 1756-TD006

Features - Chassis

Slot guides and snap-in retention for easy and secure module fit for any type of 1756 module

Direct mounting accommodates any 1756 power supply

Attribute 1756-BA1 1756-BA2 1756-BATM(1) 1756-BATA

Description Lithium battery (059 g) Lithium battery (059 g) Externally mounted battery assembly

Replacement lithium battery for 1756-BATM (5 g max lithium per each D cell contains 2 D cells)

ControlLogix controllers 1756-L61 1756-L62 1756-L63 series A

1756-L61 1756-L62 1756-L63 series B1756-L64 1756-L65

1756-L61 1756-L62 1756-L63 series A

1756-BATM battery module

GuardLogix controllers mdash 1756-L61S 1756-L62S 1756-L63S

mdash mdash

ControlLogix-XT controllers

mdash 1756-L63XT mdash mdash

(1) The 1756-BATM externally mounted battery assembly is highly recommended for use with all series A 1756-L6x controllers and provides longer battery life than the 1756-BA1 battery The 1756-BATM includes one 1756-BATA lithium battery assembly and a 1 m (328 ft) cable to connect housing to controller

32 Publication 1756-SG001P-EN-P - May 2011

Standard Chassis

The chassis backplane provides a high-speed communication path between modules and distributes power to each of the modules within the chassis

ControlLogix-XT Chassis

The ControlLogix-XT chassis support extreme temperature environments

Accessories - Chassis

Use a slot filler module to fill empty slots

Cat No Description Slots

1756-A4 ControlLogix standard chassis 4

1756-A7 7

1756-A10 10

1756-A13 13

1756-A17 17

Cat No Description Slots Temperature Range

1756-A4LXT ControlLogix-XT chassis 4 -2560 degC (-13140 degF)

1756-A5XT 5 -2570 degC (-13158 degF)

1756-A7LXT 7 -2560 degC (-13140 degF)

Cat No Description

1756-N2 Slot filler module for empty slots in standard ControlLogix chassis

1756-N2XT Slot filler module for empty slots in ControlLogix-XT chassis

Publication 1756-SG001P-EN-P - May 2011 33

ControlLogix Power Supplies

ControlLogix power supplies are used with the 1756 chassis to provide 12V 33V 5V and 24V DC power directly to the chassis backplane Select from these configurations

Standard power Redundant power ControlLogix-XT power

For detailed specifications see 1756 ControlLogix Power Supplies Specifications publication 1756-TD005

Standard Power Supplies

You mount a standard power supply directly on the left end of the chassis where it plugs directly into the backplane

ControlLogix-XT Power Supplies

The ControlLogix-XT power supplies support extreme temperature environments

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA72 ControlLogix standard AC 120V220V AC 85hellip265V AC Standard series A and series B

1756-PA75 120V220V AC 85hellip265V AC Standard series B

1756-PB72 ControlLogix standard DC 24V DC 18hellip32V DC Standard series A and series B

1756-PB75 24V DC 1832V DC Standard series B

1756-PC75 48V DC 30hellip60V DC Standard series B

1756-PH75 125V DC 90hellip143V DC Standard series B

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PAXT ControlLogix-XT AC power supply 85265V AC 120240V AC XT

1756-PBXT ControlLogix-XT DC power supply 24V DC 18hellip32V DC XT

34 Publication 1756-SG001P-EN-P - May 2011

Redundant Power Supplies

To build a redundant power supply system you need the following

Two redundant power supplies (both 1756-PA75R or 1756-PB75R) One 1756-PSCA2 chassis adapter module Two 1756-CPR2 cables to connect the power supplies to the

1756-PSCA2 chassis adapter module (091 m (3 ft) length) User-supplied annunciator wiring to connect the power supplies to the

input modules as needed

The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Accessories - Redundant Power Supplies

Visualization Products Visualization products together with Logix for control and NetLinx architecture for communication make up the Rockwell Automation Integrated Architecture strategy The visualization strategy combines Rockwell Automation expertise in Allen-Bradley electronic operator interface and industrialized personal computer hardware with Rockwell Software supervisory control software Current visualization products include the following

FactoryTalk View software PanelView Plus operator interface PanelView Plus CE operator interface Industrial computers and monitors

For more information see the Operator Interface catalog pages at httpwwwabcomenepubcatalogs1276221813761239781

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA75R ControlLogix redundant 120V220V AC 85hellip265V AC Standard series B

1756-PB75R 24V DC 192hellip32V DC Standard series B

Cat No Description Specifications

1756-PSCA2 Chassis adapter module Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Mounts directly to left side of 1756 chassis

1756-CPR2 Chassis adapter cable Connects redundant power supply to 1756-PCSA2 chassis adapter Length091 m (3 ft)

Publication 1756-SG001P-EN-P - May 2011 35

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR ltFEFF004200720075006b00200064006900730073006500200069006e006e007300740069006c006c0069006e00670065006e0065002000740069006c002000e50020006f0070007000720065007400740065002000410064006f006200650020005000440046002d0064006f006b0075006d0065006e00740065007200200066006f00720020007500740073006b00720069006600740020006100760020006800f800790020006b00760061006c00690074006500740020007000e500200062006f007200640073006b0072006900760065007200200065006c006c00650072002000700072006f006f006600650072002e0020005000440046002d0064006f006b0075006d0065006e00740065006e00650020006b0061006e002000e50070006e00650073002000690020004100630072006f00620061007400200065006c006c00650072002000410064006f00620065002000520065006100640065007200200035002e003000200065006c006c00650072002000730065006e006500720065002egt PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

GuardLogix Controllers

A GuardLogix controller is a ControlLogix controller that also provides safety control The GuardLogix system is a dual controller solutionmdashyou must use a 1756-L6xS primary controller and a 1756-LSP safety partner to achieve SIL 3CAT 4

During development safety and standard have the same rules multiple programmers online editing and forcing are all allowed Once the project is tested and ready for final validation you set the Safety Task to a SIL 3 integrity level which is then enforced by the GuardLogix controller When safety memory is locked and protected the safety logic cant be modified and all safety functions operate with SIL 3 integrity On the standard side of the GuardLogix controller all functions operate like a regular Logix controller

Use Guard IO modules for field device connectivity on Ethernet or DeviceNet networks and for safety interlocking between GuardLogix controllers use Ethernet or ControlNet networks Multiple GuardLogix controllers can share safety data for zone to zone interlocking or a single GuardLogix controller can use remote distributed safety IO between different cellsareas

In addition to the standard features of a ControlLogix controller the GuardLogix controller has these safety-related features

Application Description

SIL 1 2 3 The GuardLogix controller system is type-approved and certified for use in safety applications up to and including SIL 3 according to IEC 61508 and applications up to and including PLeCat4 according to ISO 13849-1 For more information see GuardLogix Controllers Systems Safety Reference Manual publication 1756-RM093 GuardLogix Controllers User Manual publication 1756-UM020 GuardLogix Safety Application Instruction Set Reference Manual publication 1756-RM095

Features - GuardLogix Controllers

Feature 1756-L61S 1756-L62S 1756-L63S 1756-LSP

Safety communication options Standard and safety EtherNetIP ControlNet DeviceNet

Network connections per network module 100 ControlNet (1756-CN2A) 40 ControlNet (1756-CNB) 256 EtherNetIP 128 TCP (1756-EN2x) 128 EtherNetIP 64 TCP (1756-ENBT)

Controller redundancy Not supported

Programming languages Relay ladder

Publication 1756-SG001P-EN-P - May 2011 29

ControlLogix-XT Controllers

The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh corrosive environments

When used with FLEX IO-XT products the ControlLogix-XT system can withstand temperatures range from -2070 C (-4158 F)

When used independently the ControlLogix-XT system can withstand temperature ranges from -2570 C (-13158 F)

Redundant ControlLogix Controllers

The ControlLogix controller supports controller redundancy In a redundant controller system you need these components

Two 1756 chassis each with the following the same ndash Number of slots

ndash Modules in the same slots

ndash Redundancy firmware revisions in each module

ndash Two additional ControlNet nodes outside the redundant chassis pair

You need one of these redundancy modules

One 1756-RM module per chassis that supports the followingndash Two 1756-L61 1756-L62 1761-L63 controllers or one 1756-L64

controller

ndash Maximum of seven communication modules which can be 1756-CN2 series B 1756-CN2R series B and 1756-EN2T modules

ndash One 1756-RMCx cable

One 1757-SRM module per chassis that supports the followingndash One 1756-L61 1756-L62 1756-L63 1756-L64 controller

ndash Maximum of seven communication modules which can be 1756-CNB series D or E 1756-CNBR series D or E 1756-ENBT and 1756-EWEB modules

ndash One 1757-SRCx cable

30 Publication 1756-SG001P-EN-P - May 2011

Accessories - Controllers

Memory Cards

Memory cards offer nonvolatile memory to permanently store a user program and tag data on a controller The 1756-L7x ControlLogix controller comes with 1784-SD1 Secure Digital (SD) card already installed The 1756-L6x controllers support optional CompactFlash cards that you purchase separately The memory card installs in a socket on the controller Through RSLogix 5000 software you can manually trigger the controller to save to or load from nonvolatile memory or configure the controller to load from nonvolatile memory on powerup

The GuardLogix controller does not support user program storage or retrieval by using a CompactFlash card

1756 Energy Storage Modules

Instead of a battery the 1756-L7x controller ships with a 1756-ESMCAP energy storage module (ESM) already installed

Attribute 1784-CF64 1784-CF128 1784-SD1 1784-SD2

Memory 64 MB 128 MB 1 GB 2 GB

Supported controllers 1756-L6x 1756-L7x

Weight approx 142 g (05 oz) 176 g (0062 oz)

Cat No Description

1756-ESMCAP Capacitor-based energy-storage module Comes with the controller

1756-EMNSE ESM without WallClockTime backup power Additionally you can use this ESM with a 1756-L73 (8 MB) or smaller memory-sized controller only

Use this ESM if your application requires that the installed ESM deplete its residual energy to 40 microJoule or less before transporting it into or out of your application

1756-ESMNRM Energy-storage module that secures the controller by preventing the USB connection and SD card useThis ESM provides your application an enhanced degree of security

Publication 1756-SG001P-EN-P - May 2011 31

1756 ControlLogix Batteries

Each 1756-L6x controller ships with a battery With a memory card installed the controller can be used without a battery If you do not use a battery current tag data will be at the state it was when the memory card was saved

ControlLogix Chassis The ControlLogix system is a modular system that requires a 1756 IO chassis Place any module into any slot The backplane provides a high-speed communication path between modules

All of the chassis are designed for horizontal-only back-panel mounting The chassis are available in these configurations

Standard chassis ControlLogix-XT chassis

For detailed specifications see 1756 ControlLogix Chassis Specifications Specifications publication 1756-TD006

Features - Chassis

Slot guides and snap-in retention for easy and secure module fit for any type of 1756 module

Direct mounting accommodates any 1756 power supply

Attribute 1756-BA1 1756-BA2 1756-BATM(1) 1756-BATA

Description Lithium battery (059 g) Lithium battery (059 g) Externally mounted battery assembly

Replacement lithium battery for 1756-BATM (5 g max lithium per each D cell contains 2 D cells)

ControlLogix controllers 1756-L61 1756-L62 1756-L63 series A

1756-L61 1756-L62 1756-L63 series B1756-L64 1756-L65

1756-L61 1756-L62 1756-L63 series A

1756-BATM battery module

GuardLogix controllers mdash 1756-L61S 1756-L62S 1756-L63S

mdash mdash

ControlLogix-XT controllers

mdash 1756-L63XT mdash mdash

(1) The 1756-BATM externally mounted battery assembly is highly recommended for use with all series A 1756-L6x controllers and provides longer battery life than the 1756-BA1 battery The 1756-BATM includes one 1756-BATA lithium battery assembly and a 1 m (328 ft) cable to connect housing to controller

32 Publication 1756-SG001P-EN-P - May 2011

Standard Chassis

The chassis backplane provides a high-speed communication path between modules and distributes power to each of the modules within the chassis

ControlLogix-XT Chassis

The ControlLogix-XT chassis support extreme temperature environments

Accessories - Chassis

Use a slot filler module to fill empty slots

Cat No Description Slots

1756-A4 ControlLogix standard chassis 4

1756-A7 7

1756-A10 10

1756-A13 13

1756-A17 17

Cat No Description Slots Temperature Range

1756-A4LXT ControlLogix-XT chassis 4 -2560 degC (-13140 degF)

1756-A5XT 5 -2570 degC (-13158 degF)

1756-A7LXT 7 -2560 degC (-13140 degF)

Cat No Description

1756-N2 Slot filler module for empty slots in standard ControlLogix chassis

1756-N2XT Slot filler module for empty slots in ControlLogix-XT chassis

Publication 1756-SG001P-EN-P - May 2011 33

ControlLogix Power Supplies

ControlLogix power supplies are used with the 1756 chassis to provide 12V 33V 5V and 24V DC power directly to the chassis backplane Select from these configurations

Standard power Redundant power ControlLogix-XT power

For detailed specifications see 1756 ControlLogix Power Supplies Specifications publication 1756-TD005

Standard Power Supplies

You mount a standard power supply directly on the left end of the chassis where it plugs directly into the backplane

ControlLogix-XT Power Supplies

The ControlLogix-XT power supplies support extreme temperature environments

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA72 ControlLogix standard AC 120V220V AC 85hellip265V AC Standard series A and series B

1756-PA75 120V220V AC 85hellip265V AC Standard series B

1756-PB72 ControlLogix standard DC 24V DC 18hellip32V DC Standard series A and series B

1756-PB75 24V DC 1832V DC Standard series B

1756-PC75 48V DC 30hellip60V DC Standard series B

1756-PH75 125V DC 90hellip143V DC Standard series B

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PAXT ControlLogix-XT AC power supply 85265V AC 120240V AC XT

1756-PBXT ControlLogix-XT DC power supply 24V DC 18hellip32V DC XT

34 Publication 1756-SG001P-EN-P - May 2011

Redundant Power Supplies

To build a redundant power supply system you need the following

Two redundant power supplies (both 1756-PA75R or 1756-PB75R) One 1756-PSCA2 chassis adapter module Two 1756-CPR2 cables to connect the power supplies to the

1756-PSCA2 chassis adapter module (091 m (3 ft) length) User-supplied annunciator wiring to connect the power supplies to the

input modules as needed

The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Accessories - Redundant Power Supplies

Visualization Products Visualization products together with Logix for control and NetLinx architecture for communication make up the Rockwell Automation Integrated Architecture strategy The visualization strategy combines Rockwell Automation expertise in Allen-Bradley electronic operator interface and industrialized personal computer hardware with Rockwell Software supervisory control software Current visualization products include the following

FactoryTalk View software PanelView Plus operator interface PanelView Plus CE operator interface Industrial computers and monitors

For more information see the Operator Interface catalog pages at httpwwwabcomenepubcatalogs1276221813761239781

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA75R ControlLogix redundant 120V220V AC 85hellip265V AC Standard series B

1756-PB75R 24V DC 192hellip32V DC Standard series B

Cat No Description Specifications

1756-PSCA2 Chassis adapter module Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Mounts directly to left side of 1756 chassis

1756-CPR2 Chassis adapter cable Connects redundant power supply to 1756-PCSA2 chassis adapter Length091 m (3 ft)

Publication 1756-SG001P-EN-P - May 2011 35

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

ControlLogix-XT Controllers

The ControlLogix-XT controllers function in the same way as the traditional ControlLogix controllers The ControlLogix-XT products include control and communication system components that are conformally coated to extend product life in harsh corrosive environments

When used with FLEX IO-XT products the ControlLogix-XT system can withstand temperatures range from -2070 C (-4158 F)

When used independently the ControlLogix-XT system can withstand temperature ranges from -2570 C (-13158 F)

Redundant ControlLogix Controllers

The ControlLogix controller supports controller redundancy In a redundant controller system you need these components

Two 1756 chassis each with the following the same ndash Number of slots

ndash Modules in the same slots

ndash Redundancy firmware revisions in each module

ndash Two additional ControlNet nodes outside the redundant chassis pair

You need one of these redundancy modules

One 1756-RM module per chassis that supports the followingndash Two 1756-L61 1756-L62 1761-L63 controllers or one 1756-L64

controller

ndash Maximum of seven communication modules which can be 1756-CN2 series B 1756-CN2R series B and 1756-EN2T modules

ndash One 1756-RMCx cable

One 1757-SRM module per chassis that supports the followingndash One 1756-L61 1756-L62 1756-L63 1756-L64 controller

ndash Maximum of seven communication modules which can be 1756-CNB series D or E 1756-CNBR series D or E 1756-ENBT and 1756-EWEB modules

ndash One 1757-SRCx cable

30 Publication 1756-SG001P-EN-P - May 2011

Accessories - Controllers

Memory Cards

Memory cards offer nonvolatile memory to permanently store a user program and tag data on a controller The 1756-L7x ControlLogix controller comes with 1784-SD1 Secure Digital (SD) card already installed The 1756-L6x controllers support optional CompactFlash cards that you purchase separately The memory card installs in a socket on the controller Through RSLogix 5000 software you can manually trigger the controller to save to or load from nonvolatile memory or configure the controller to load from nonvolatile memory on powerup

The GuardLogix controller does not support user program storage or retrieval by using a CompactFlash card

1756 Energy Storage Modules

Instead of a battery the 1756-L7x controller ships with a 1756-ESMCAP energy storage module (ESM) already installed

Attribute 1784-CF64 1784-CF128 1784-SD1 1784-SD2

Memory 64 MB 128 MB 1 GB 2 GB

Supported controllers 1756-L6x 1756-L7x

Weight approx 142 g (05 oz) 176 g (0062 oz)

Cat No Description

1756-ESMCAP Capacitor-based energy-storage module Comes with the controller

1756-EMNSE ESM without WallClockTime backup power Additionally you can use this ESM with a 1756-L73 (8 MB) or smaller memory-sized controller only

Use this ESM if your application requires that the installed ESM deplete its residual energy to 40 microJoule or less before transporting it into or out of your application

1756-ESMNRM Energy-storage module that secures the controller by preventing the USB connection and SD card useThis ESM provides your application an enhanced degree of security

Publication 1756-SG001P-EN-P - May 2011 31

1756 ControlLogix Batteries

Each 1756-L6x controller ships with a battery With a memory card installed the controller can be used without a battery If you do not use a battery current tag data will be at the state it was when the memory card was saved

ControlLogix Chassis The ControlLogix system is a modular system that requires a 1756 IO chassis Place any module into any slot The backplane provides a high-speed communication path between modules

All of the chassis are designed for horizontal-only back-panel mounting The chassis are available in these configurations

Standard chassis ControlLogix-XT chassis

For detailed specifications see 1756 ControlLogix Chassis Specifications Specifications publication 1756-TD006

Features - Chassis

Slot guides and snap-in retention for easy and secure module fit for any type of 1756 module

Direct mounting accommodates any 1756 power supply

Attribute 1756-BA1 1756-BA2 1756-BATM(1) 1756-BATA

Description Lithium battery (059 g) Lithium battery (059 g) Externally mounted battery assembly

Replacement lithium battery for 1756-BATM (5 g max lithium per each D cell contains 2 D cells)

ControlLogix controllers 1756-L61 1756-L62 1756-L63 series A

1756-L61 1756-L62 1756-L63 series B1756-L64 1756-L65

1756-L61 1756-L62 1756-L63 series A

1756-BATM battery module

GuardLogix controllers mdash 1756-L61S 1756-L62S 1756-L63S

mdash mdash

ControlLogix-XT controllers

mdash 1756-L63XT mdash mdash

(1) The 1756-BATM externally mounted battery assembly is highly recommended for use with all series A 1756-L6x controllers and provides longer battery life than the 1756-BA1 battery The 1756-BATM includes one 1756-BATA lithium battery assembly and a 1 m (328 ft) cable to connect housing to controller

32 Publication 1756-SG001P-EN-P - May 2011

Standard Chassis

The chassis backplane provides a high-speed communication path between modules and distributes power to each of the modules within the chassis

ControlLogix-XT Chassis

The ControlLogix-XT chassis support extreme temperature environments

Accessories - Chassis

Use a slot filler module to fill empty slots

Cat No Description Slots

1756-A4 ControlLogix standard chassis 4

1756-A7 7

1756-A10 10

1756-A13 13

1756-A17 17

Cat No Description Slots Temperature Range

1756-A4LXT ControlLogix-XT chassis 4 -2560 degC (-13140 degF)

1756-A5XT 5 -2570 degC (-13158 degF)

1756-A7LXT 7 -2560 degC (-13140 degF)

Cat No Description

1756-N2 Slot filler module for empty slots in standard ControlLogix chassis

1756-N2XT Slot filler module for empty slots in ControlLogix-XT chassis

Publication 1756-SG001P-EN-P - May 2011 33

ControlLogix Power Supplies

ControlLogix power supplies are used with the 1756 chassis to provide 12V 33V 5V and 24V DC power directly to the chassis backplane Select from these configurations

Standard power Redundant power ControlLogix-XT power

For detailed specifications see 1756 ControlLogix Power Supplies Specifications publication 1756-TD005

Standard Power Supplies

You mount a standard power supply directly on the left end of the chassis where it plugs directly into the backplane

ControlLogix-XT Power Supplies

The ControlLogix-XT power supplies support extreme temperature environments

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA72 ControlLogix standard AC 120V220V AC 85hellip265V AC Standard series A and series B

1756-PA75 120V220V AC 85hellip265V AC Standard series B

1756-PB72 ControlLogix standard DC 24V DC 18hellip32V DC Standard series A and series B

1756-PB75 24V DC 1832V DC Standard series B

1756-PC75 48V DC 30hellip60V DC Standard series B

1756-PH75 125V DC 90hellip143V DC Standard series B

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PAXT ControlLogix-XT AC power supply 85265V AC 120240V AC XT

1756-PBXT ControlLogix-XT DC power supply 24V DC 18hellip32V DC XT

34 Publication 1756-SG001P-EN-P - May 2011

Redundant Power Supplies

To build a redundant power supply system you need the following

Two redundant power supplies (both 1756-PA75R or 1756-PB75R) One 1756-PSCA2 chassis adapter module Two 1756-CPR2 cables to connect the power supplies to the

1756-PSCA2 chassis adapter module (091 m (3 ft) length) User-supplied annunciator wiring to connect the power supplies to the

input modules as needed

The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Accessories - Redundant Power Supplies

Visualization Products Visualization products together with Logix for control and NetLinx architecture for communication make up the Rockwell Automation Integrated Architecture strategy The visualization strategy combines Rockwell Automation expertise in Allen-Bradley electronic operator interface and industrialized personal computer hardware with Rockwell Software supervisory control software Current visualization products include the following

FactoryTalk View software PanelView Plus operator interface PanelView Plus CE operator interface Industrial computers and monitors

For more information see the Operator Interface catalog pages at httpwwwabcomenepubcatalogs1276221813761239781

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA75R ControlLogix redundant 120V220V AC 85hellip265V AC Standard series B

1756-PB75R 24V DC 192hellip32V DC Standard series B

Cat No Description Specifications

1756-PSCA2 Chassis adapter module Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Mounts directly to left side of 1756 chassis

1756-CPR2 Chassis adapter cable Connects redundant power supply to 1756-PCSA2 chassis adapter Length091 m (3 ft)

Publication 1756-SG001P-EN-P - May 2011 35

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

Accessories - Controllers

Memory Cards

Memory cards offer nonvolatile memory to permanently store a user program and tag data on a controller The 1756-L7x ControlLogix controller comes with 1784-SD1 Secure Digital (SD) card already installed The 1756-L6x controllers support optional CompactFlash cards that you purchase separately The memory card installs in a socket on the controller Through RSLogix 5000 software you can manually trigger the controller to save to or load from nonvolatile memory or configure the controller to load from nonvolatile memory on powerup

The GuardLogix controller does not support user program storage or retrieval by using a CompactFlash card

1756 Energy Storage Modules

Instead of a battery the 1756-L7x controller ships with a 1756-ESMCAP energy storage module (ESM) already installed

Attribute 1784-CF64 1784-CF128 1784-SD1 1784-SD2

Memory 64 MB 128 MB 1 GB 2 GB

Supported controllers 1756-L6x 1756-L7x

Weight approx 142 g (05 oz) 176 g (0062 oz)

Cat No Description

1756-ESMCAP Capacitor-based energy-storage module Comes with the controller

1756-EMNSE ESM without WallClockTime backup power Additionally you can use this ESM with a 1756-L73 (8 MB) or smaller memory-sized controller only

Use this ESM if your application requires that the installed ESM deplete its residual energy to 40 microJoule or less before transporting it into or out of your application

1756-ESMNRM Energy-storage module that secures the controller by preventing the USB connection and SD card useThis ESM provides your application an enhanced degree of security

Publication 1756-SG001P-EN-P - May 2011 31

1756 ControlLogix Batteries

Each 1756-L6x controller ships with a battery With a memory card installed the controller can be used without a battery If you do not use a battery current tag data will be at the state it was when the memory card was saved

ControlLogix Chassis The ControlLogix system is a modular system that requires a 1756 IO chassis Place any module into any slot The backplane provides a high-speed communication path between modules

All of the chassis are designed for horizontal-only back-panel mounting The chassis are available in these configurations

Standard chassis ControlLogix-XT chassis

For detailed specifications see 1756 ControlLogix Chassis Specifications Specifications publication 1756-TD006

Features - Chassis

Slot guides and snap-in retention for easy and secure module fit for any type of 1756 module

Direct mounting accommodates any 1756 power supply

Attribute 1756-BA1 1756-BA2 1756-BATM(1) 1756-BATA

Description Lithium battery (059 g) Lithium battery (059 g) Externally mounted battery assembly

Replacement lithium battery for 1756-BATM (5 g max lithium per each D cell contains 2 D cells)

ControlLogix controllers 1756-L61 1756-L62 1756-L63 series A

1756-L61 1756-L62 1756-L63 series B1756-L64 1756-L65

1756-L61 1756-L62 1756-L63 series A

1756-BATM battery module

GuardLogix controllers mdash 1756-L61S 1756-L62S 1756-L63S

mdash mdash

ControlLogix-XT controllers

mdash 1756-L63XT mdash mdash

(1) The 1756-BATM externally mounted battery assembly is highly recommended for use with all series A 1756-L6x controllers and provides longer battery life than the 1756-BA1 battery The 1756-BATM includes one 1756-BATA lithium battery assembly and a 1 m (328 ft) cable to connect housing to controller

32 Publication 1756-SG001P-EN-P - May 2011

Standard Chassis

The chassis backplane provides a high-speed communication path between modules and distributes power to each of the modules within the chassis

ControlLogix-XT Chassis

The ControlLogix-XT chassis support extreme temperature environments

Accessories - Chassis

Use a slot filler module to fill empty slots

Cat No Description Slots

1756-A4 ControlLogix standard chassis 4

1756-A7 7

1756-A10 10

1756-A13 13

1756-A17 17

Cat No Description Slots Temperature Range

1756-A4LXT ControlLogix-XT chassis 4 -2560 degC (-13140 degF)

1756-A5XT 5 -2570 degC (-13158 degF)

1756-A7LXT 7 -2560 degC (-13140 degF)

Cat No Description

1756-N2 Slot filler module for empty slots in standard ControlLogix chassis

1756-N2XT Slot filler module for empty slots in ControlLogix-XT chassis

Publication 1756-SG001P-EN-P - May 2011 33

ControlLogix Power Supplies

ControlLogix power supplies are used with the 1756 chassis to provide 12V 33V 5V and 24V DC power directly to the chassis backplane Select from these configurations

Standard power Redundant power ControlLogix-XT power

For detailed specifications see 1756 ControlLogix Power Supplies Specifications publication 1756-TD005

Standard Power Supplies

You mount a standard power supply directly on the left end of the chassis where it plugs directly into the backplane

ControlLogix-XT Power Supplies

The ControlLogix-XT power supplies support extreme temperature environments

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA72 ControlLogix standard AC 120V220V AC 85hellip265V AC Standard series A and series B

1756-PA75 120V220V AC 85hellip265V AC Standard series B

1756-PB72 ControlLogix standard DC 24V DC 18hellip32V DC Standard series A and series B

1756-PB75 24V DC 1832V DC Standard series B

1756-PC75 48V DC 30hellip60V DC Standard series B

1756-PH75 125V DC 90hellip143V DC Standard series B

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PAXT ControlLogix-XT AC power supply 85265V AC 120240V AC XT

1756-PBXT ControlLogix-XT DC power supply 24V DC 18hellip32V DC XT

34 Publication 1756-SG001P-EN-P - May 2011

Redundant Power Supplies

To build a redundant power supply system you need the following

Two redundant power supplies (both 1756-PA75R or 1756-PB75R) One 1756-PSCA2 chassis adapter module Two 1756-CPR2 cables to connect the power supplies to the

1756-PSCA2 chassis adapter module (091 m (3 ft) length) User-supplied annunciator wiring to connect the power supplies to the

input modules as needed

The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Accessories - Redundant Power Supplies

Visualization Products Visualization products together with Logix for control and NetLinx architecture for communication make up the Rockwell Automation Integrated Architecture strategy The visualization strategy combines Rockwell Automation expertise in Allen-Bradley electronic operator interface and industrialized personal computer hardware with Rockwell Software supervisory control software Current visualization products include the following

FactoryTalk View software PanelView Plus operator interface PanelView Plus CE operator interface Industrial computers and monitors

For more information see the Operator Interface catalog pages at httpwwwabcomenepubcatalogs1276221813761239781

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA75R ControlLogix redundant 120V220V AC 85hellip265V AC Standard series B

1756-PB75R 24V DC 192hellip32V DC Standard series B

Cat No Description Specifications

1756-PSCA2 Chassis adapter module Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Mounts directly to left side of 1756 chassis

1756-CPR2 Chassis adapter cable Connects redundant power supply to 1756-PCSA2 chassis adapter Length091 m (3 ft)

Publication 1756-SG001P-EN-P - May 2011 35

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

1756 ControlLogix Batteries

Each 1756-L6x controller ships with a battery With a memory card installed the controller can be used without a battery If you do not use a battery current tag data will be at the state it was when the memory card was saved

ControlLogix Chassis The ControlLogix system is a modular system that requires a 1756 IO chassis Place any module into any slot The backplane provides a high-speed communication path between modules

All of the chassis are designed for horizontal-only back-panel mounting The chassis are available in these configurations

Standard chassis ControlLogix-XT chassis

For detailed specifications see 1756 ControlLogix Chassis Specifications Specifications publication 1756-TD006

Features - Chassis

Slot guides and snap-in retention for easy and secure module fit for any type of 1756 module

Direct mounting accommodates any 1756 power supply

Attribute 1756-BA1 1756-BA2 1756-BATM(1) 1756-BATA

Description Lithium battery (059 g) Lithium battery (059 g) Externally mounted battery assembly

Replacement lithium battery for 1756-BATM (5 g max lithium per each D cell contains 2 D cells)

ControlLogix controllers 1756-L61 1756-L62 1756-L63 series A

1756-L61 1756-L62 1756-L63 series B1756-L64 1756-L65

1756-L61 1756-L62 1756-L63 series A

1756-BATM battery module

GuardLogix controllers mdash 1756-L61S 1756-L62S 1756-L63S

mdash mdash

ControlLogix-XT controllers

mdash 1756-L63XT mdash mdash

(1) The 1756-BATM externally mounted battery assembly is highly recommended for use with all series A 1756-L6x controllers and provides longer battery life than the 1756-BA1 battery The 1756-BATM includes one 1756-BATA lithium battery assembly and a 1 m (328 ft) cable to connect housing to controller

32 Publication 1756-SG001P-EN-P - May 2011

Standard Chassis

The chassis backplane provides a high-speed communication path between modules and distributes power to each of the modules within the chassis

ControlLogix-XT Chassis

The ControlLogix-XT chassis support extreme temperature environments

Accessories - Chassis

Use a slot filler module to fill empty slots

Cat No Description Slots

1756-A4 ControlLogix standard chassis 4

1756-A7 7

1756-A10 10

1756-A13 13

1756-A17 17

Cat No Description Slots Temperature Range

1756-A4LXT ControlLogix-XT chassis 4 -2560 degC (-13140 degF)

1756-A5XT 5 -2570 degC (-13158 degF)

1756-A7LXT 7 -2560 degC (-13140 degF)

Cat No Description

1756-N2 Slot filler module for empty slots in standard ControlLogix chassis

1756-N2XT Slot filler module for empty slots in ControlLogix-XT chassis

Publication 1756-SG001P-EN-P - May 2011 33

ControlLogix Power Supplies

ControlLogix power supplies are used with the 1756 chassis to provide 12V 33V 5V and 24V DC power directly to the chassis backplane Select from these configurations

Standard power Redundant power ControlLogix-XT power

For detailed specifications see 1756 ControlLogix Power Supplies Specifications publication 1756-TD005

Standard Power Supplies

You mount a standard power supply directly on the left end of the chassis where it plugs directly into the backplane

ControlLogix-XT Power Supplies

The ControlLogix-XT power supplies support extreme temperature environments

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA72 ControlLogix standard AC 120V220V AC 85hellip265V AC Standard series A and series B

1756-PA75 120V220V AC 85hellip265V AC Standard series B

1756-PB72 ControlLogix standard DC 24V DC 18hellip32V DC Standard series A and series B

1756-PB75 24V DC 1832V DC Standard series B

1756-PC75 48V DC 30hellip60V DC Standard series B

1756-PH75 125V DC 90hellip143V DC Standard series B

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PAXT ControlLogix-XT AC power supply 85265V AC 120240V AC XT

1756-PBXT ControlLogix-XT DC power supply 24V DC 18hellip32V DC XT

34 Publication 1756-SG001P-EN-P - May 2011

Redundant Power Supplies

To build a redundant power supply system you need the following

Two redundant power supplies (both 1756-PA75R or 1756-PB75R) One 1756-PSCA2 chassis adapter module Two 1756-CPR2 cables to connect the power supplies to the

1756-PSCA2 chassis adapter module (091 m (3 ft) length) User-supplied annunciator wiring to connect the power supplies to the

input modules as needed

The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Accessories - Redundant Power Supplies

Visualization Products Visualization products together with Logix for control and NetLinx architecture for communication make up the Rockwell Automation Integrated Architecture strategy The visualization strategy combines Rockwell Automation expertise in Allen-Bradley electronic operator interface and industrialized personal computer hardware with Rockwell Software supervisory control software Current visualization products include the following

FactoryTalk View software PanelView Plus operator interface PanelView Plus CE operator interface Industrial computers and monitors

For more information see the Operator Interface catalog pages at httpwwwabcomenepubcatalogs1276221813761239781

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA75R ControlLogix redundant 120V220V AC 85hellip265V AC Standard series B

1756-PB75R 24V DC 192hellip32V DC Standard series B

Cat No Description Specifications

1756-PSCA2 Chassis adapter module Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Mounts directly to left side of 1756 chassis

1756-CPR2 Chassis adapter cable Connects redundant power supply to 1756-PCSA2 chassis adapter Length091 m (3 ft)

Publication 1756-SG001P-EN-P - May 2011 35

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

Standard Chassis

The chassis backplane provides a high-speed communication path between modules and distributes power to each of the modules within the chassis

ControlLogix-XT Chassis

The ControlLogix-XT chassis support extreme temperature environments

Accessories - Chassis

Use a slot filler module to fill empty slots

Cat No Description Slots

1756-A4 ControlLogix standard chassis 4

1756-A7 7

1756-A10 10

1756-A13 13

1756-A17 17

Cat No Description Slots Temperature Range

1756-A4LXT ControlLogix-XT chassis 4 -2560 degC (-13140 degF)

1756-A5XT 5 -2570 degC (-13158 degF)

1756-A7LXT 7 -2560 degC (-13140 degF)

Cat No Description

1756-N2 Slot filler module for empty slots in standard ControlLogix chassis

1756-N2XT Slot filler module for empty slots in ControlLogix-XT chassis

Publication 1756-SG001P-EN-P - May 2011 33

ControlLogix Power Supplies

ControlLogix power supplies are used with the 1756 chassis to provide 12V 33V 5V and 24V DC power directly to the chassis backplane Select from these configurations

Standard power Redundant power ControlLogix-XT power

For detailed specifications see 1756 ControlLogix Power Supplies Specifications publication 1756-TD005

Standard Power Supplies

You mount a standard power supply directly on the left end of the chassis where it plugs directly into the backplane

ControlLogix-XT Power Supplies

The ControlLogix-XT power supplies support extreme temperature environments

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA72 ControlLogix standard AC 120V220V AC 85hellip265V AC Standard series A and series B

1756-PA75 120V220V AC 85hellip265V AC Standard series B

1756-PB72 ControlLogix standard DC 24V DC 18hellip32V DC Standard series A and series B

1756-PB75 24V DC 1832V DC Standard series B

1756-PC75 48V DC 30hellip60V DC Standard series B

1756-PH75 125V DC 90hellip143V DC Standard series B

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PAXT ControlLogix-XT AC power supply 85265V AC 120240V AC XT

1756-PBXT ControlLogix-XT DC power supply 24V DC 18hellip32V DC XT

34 Publication 1756-SG001P-EN-P - May 2011

Redundant Power Supplies

To build a redundant power supply system you need the following

Two redundant power supplies (both 1756-PA75R or 1756-PB75R) One 1756-PSCA2 chassis adapter module Two 1756-CPR2 cables to connect the power supplies to the

1756-PSCA2 chassis adapter module (091 m (3 ft) length) User-supplied annunciator wiring to connect the power supplies to the

input modules as needed

The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Accessories - Redundant Power Supplies

Visualization Products Visualization products together with Logix for control and NetLinx architecture for communication make up the Rockwell Automation Integrated Architecture strategy The visualization strategy combines Rockwell Automation expertise in Allen-Bradley electronic operator interface and industrialized personal computer hardware with Rockwell Software supervisory control software Current visualization products include the following

FactoryTalk View software PanelView Plus operator interface PanelView Plus CE operator interface Industrial computers and monitors

For more information see the Operator Interface catalog pages at httpwwwabcomenepubcatalogs1276221813761239781

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA75R ControlLogix redundant 120V220V AC 85hellip265V AC Standard series B

1756-PB75R 24V DC 192hellip32V DC Standard series B

Cat No Description Specifications

1756-PSCA2 Chassis adapter module Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Mounts directly to left side of 1756 chassis

1756-CPR2 Chassis adapter cable Connects redundant power supply to 1756-PCSA2 chassis adapter Length091 m (3 ft)

Publication 1756-SG001P-EN-P - May 2011 35

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

ControlLogix Power Supplies

ControlLogix power supplies are used with the 1756 chassis to provide 12V 33V 5V and 24V DC power directly to the chassis backplane Select from these configurations

Standard power Redundant power ControlLogix-XT power

For detailed specifications see 1756 ControlLogix Power Supplies Specifications publication 1756-TD005

Standard Power Supplies

You mount a standard power supply directly on the left end of the chassis where it plugs directly into the backplane

ControlLogix-XT Power Supplies

The ControlLogix-XT power supplies support extreme temperature environments

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA72 ControlLogix standard AC 120V220V AC 85hellip265V AC Standard series A and series B

1756-PA75 120V220V AC 85hellip265V AC Standard series B

1756-PB72 ControlLogix standard DC 24V DC 18hellip32V DC Standard series A and series B

1756-PB75 24V DC 1832V DC Standard series B

1756-PC75 48V DC 30hellip60V DC Standard series B

1756-PH75 125V DC 90hellip143V DC Standard series B

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PAXT ControlLogix-XT AC power supply 85265V AC 120240V AC XT

1756-PBXT ControlLogix-XT DC power supply 24V DC 18hellip32V DC XT

34 Publication 1756-SG001P-EN-P - May 2011

Redundant Power Supplies

To build a redundant power supply system you need the following

Two redundant power supplies (both 1756-PA75R or 1756-PB75R) One 1756-PSCA2 chassis adapter module Two 1756-CPR2 cables to connect the power supplies to the

1756-PSCA2 chassis adapter module (091 m (3 ft) length) User-supplied annunciator wiring to connect the power supplies to the

input modules as needed

The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Accessories - Redundant Power Supplies

Visualization Products Visualization products together with Logix for control and NetLinx architecture for communication make up the Rockwell Automation Integrated Architecture strategy The visualization strategy combines Rockwell Automation expertise in Allen-Bradley electronic operator interface and industrialized personal computer hardware with Rockwell Software supervisory control software Current visualization products include the following

FactoryTalk View software PanelView Plus operator interface PanelView Plus CE operator interface Industrial computers and monitors

For more information see the Operator Interface catalog pages at httpwwwabcomenepubcatalogs1276221813761239781

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA75R ControlLogix redundant 120V220V AC 85hellip265V AC Standard series B

1756-PB75R 24V DC 192hellip32V DC Standard series B

Cat No Description Specifications

1756-PSCA2 Chassis adapter module Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Mounts directly to left side of 1756 chassis

1756-CPR2 Chassis adapter cable Connects redundant power supply to 1756-PCSA2 chassis adapter Length091 m (3 ft)

Publication 1756-SG001P-EN-P - May 2011 35

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP ltFEFF005500740069006c0069006300650020006500730074006100200063006f006e0066006900670075007200610063006900f3006e0020007000610072006100200063007200650061007200200064006f00630075006d0065006e0074006f0073002000640065002000410064006f0062006500200050004400460020007000610072006100200063006f006e00730065006700750069007200200069006d0070007200650073006900f3006e002000640065002000630061006c006900640061006400200065006e00200069006d0070007200650073006f0072006100730020006400650020006500730063007200690074006f00720069006f00200079002000680065007200720061006d00690065006e00740061007300200064006500200063006f00720072006500630063006900f3006e002e002000530065002000700075006500640065006e00200061006200720069007200200064006f00630075006d0065006e0074006f00730020005000440046002000630072006500610064006f007300200063006f006e0020004100630072006f006200610074002c002000410064006f00620065002000520065006100640065007200200035002e003000200079002000760065007200730069006f006e0065007300200070006f00730074006500720069006f007200650073002egt FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

Redundant Power Supplies

To build a redundant power supply system you need the following

Two redundant power supplies (both 1756-PA75R or 1756-PB75R) One 1756-PSCA2 chassis adapter module Two 1756-CPR2 cables to connect the power supplies to the

1756-PSCA2 chassis adapter module (091 m (3 ft) length) User-supplied annunciator wiring to connect the power supplies to the

input modules as needed

The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Accessories - Redundant Power Supplies

Visualization Products Visualization products together with Logix for control and NetLinx architecture for communication make up the Rockwell Automation Integrated Architecture strategy The visualization strategy combines Rockwell Automation expertise in Allen-Bradley electronic operator interface and industrialized personal computer hardware with Rockwell Software supervisory control software Current visualization products include the following

FactoryTalk View software PanelView Plus operator interface PanelView Plus CE operator interface Industrial computers and monitors

For more information see the Operator Interface catalog pages at httpwwwabcomenepubcatalogs1276221813761239781

Cat No Description Voltage Category Operating Voltage Range

Chassis

1756-PA75R ControlLogix redundant 120V220V AC 85hellip265V AC Standard series B

1756-PB75R 24V DC 192hellip32V DC Standard series B

Cat No Description Specifications

1756-PSCA2 Chassis adapter module Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane

Mounts directly to left side of 1756 chassis

1756-CPR2 Chassis adapter cable Connects redundant power supply to 1756-PCSA2 chassis adapter Length091 m (3 ft)

Publication 1756-SG001P-EN-P - May 2011 35

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR ltFEFF004200720075006b00200064006900730073006500200069006e006e007300740069006c006c0069006e00670065006e0065002000740069006c002000e50020006f0070007000720065007400740065002000410064006f006200650020005000440046002d0064006f006b0075006d0065006e00740065007200200066006f00720020007500740073006b00720069006600740020006100760020006800f800790020006b00760061006c00690074006500740020007000e500200062006f007200640073006b0072006900760065007200200065006c006c00650072002000700072006f006f006600650072002e0020005000440046002d0064006f006b0075006d0065006e00740065006e00650020006b0061006e002000e50070006e00650073002000690020004100630072006f00620061007400200065006c006c00650072002000410064006f00620065002000520065006100640065007200200035002e003000200065006c006c00650072002000730065006e006500720065002egt PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

Programming Software Your selection of modules and network configuration determines what software packages you need to configure and program your system

1756 System Software

If you have You need Order

1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series

1756 SERCOS or analog motion module

1756-CN2 1756-CN2R1756-CN2RXT1756-CNB 1756-CNBRControlNet communication module

RSNetWorx for ControlNet software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-CNETL3 (RSNetWorx for ControlNet)

1756-DNBDeviceNet communication module

RSNetWorx for DeviceNet software(comes with the StandardNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324-RLD300NXENE (RSNetWorx option)or9324-RLD700NXENE (RSLogix 5000 Professional software)or9357-DNETL3 (RSNetWorx for DeviceNet)

1756-EN2F 1756-EN2T1756-EN2TX1756-ENBT 1756-EWEBEtherNetIP communication module(set the IP address)

RSLinx softwareorBOOTPDHCP server utility to set IP addresses(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

Optional RSNetWorx for EtherNetIP software(comes with the StandardRSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software)

9324 seriesOptional 9357-ENETL3 (RSNetWorx for EtherNetIP)

1756-DHRIO 1756-DHRIOXT communication module1756-DH485 communication module

RSLinx software 9324 series

1757-FFLD2 1757-FFLD41757-FFLDC2 1757-FFLDC4Foundation Fieldbus linking device

RSFieldbus configuration software 9308 series

Communication card in a workstation RSLinx software(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)

9324 series

36 Publication 1756-SG001P-EN-P - May 2011

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN ltFEFF004200720075006700200069006e0064007300740069006c006c0069006e006700650072006e0065002000740069006c0020006100740020006f007000720065007400740065002000410064006f006200650020005000440046002d0064006f006b0075006d0065006e007400650072002000740069006c0020006b00760061006c00690074006500740073007500640073006b007200690076006e0069006e006700200065006c006c006500720020006b006f007200720065006b007400750072006c00e60073006e0069006e0067002e0020004400650020006f007000720065007400740065006400650020005000440046002d0064006f006b0075006d0065006e0074006500720020006b0061006e002000e50062006e00650073002000690020004100630072006f00620061007400200065006c006c006500720020004100630072006f006200610074002000520065006100640065007200200035002e00300020006f00670020006e0079006500720065002egt DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder structured text function block diagram and sequential function chart editors

Description Value

Personal computer Pentium 3 833 MHz minPentium 4 28 GHz (or better) recommended

Supported operating systems RSLogix 5000 software version 19 has been tested on these operating systems Microsoft Windows 7 Professional (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (64-bit) User Account Control (UAC) set to Always notify Microsoft Windows 7 Home Premium (32-bit) User Account Control (UAC) set to Always notify Microsoft Windows Vista Business (32-bit) Service Pack 2 User Account Control (UAC) tuned on Microsoft Windows XP Professional Service Pack 3 Microsoft Windows Server 2008 Standard Edition Service Pack 2

This version is expected to operate correctly on all editions and service packs of these operating systems but has not been tested Microsoft Windows 7 Microsoft Windows Vista Microsoft Windows XP Microsoft Windows Server 2008 Microsoft Windows Server 2003

RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems and have not been tested on those operating systems RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operation systems RSLogix 5000 software version 17 is supported only on Microsoft Windows Vista with User Account Control (UAC) turned offThe Chinese Japanese and Korean editions of RSLogix 5000 software are supported only on Microsoft Windows Vista Microsoft Windows XP and Microsoft Windows Server 2003 operating systemRSLogix 5000 software also does not support Windows NT Workstation 40 Windows NT 351 Windows NT 350 Windows Me Windows 98SE Windows 98 Windows 95 or Windows 3x operating systems Starting with version 18 RSLogix 5000 software does not support Microsoft Windows 2000

RAM 512 MB min1 GB recommended

Hard disk space 3 GB of free hard disk space (or more based on application requirements)

Optical drives DVD-ROM drive

Video 1024 x 768 pixels True Colors min1280 x 1024 pixels True Colors recommended

Publication 1756-SG001P-EN-P - May 2011 37

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA ltFEFF005500740069006c0069007a007a006100720065002000710075006500730074006500200069006d0070006f007300740061007a0069006f006e00690020007000650072002000630072006500610072006500200064006f00630075006d0065006e00740069002000410064006f006200650020005000440046002000700065007200200075006e00610020007300740061006d007000610020006400690020007100750061006c0069007400e00020007300750020007300740061006d00700061006e0074006900200065002000700072006f006f0066006500720020006400650073006b0074006f0070002e0020004900200064006f00630075006d0065006e007400690020005000440046002000630072006500610074006900200070006f00730073006f006e006f0020006500730073006500720065002000610070006500720074006900200063006f006e0020004100630072006f00620061007400200065002000410064006f00620065002000520065006100640065007200200035002e003000200065002000760065007200730069006f006e006900200073007500630063006500730073006900760065002egt JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

RSLogix 5000 Enterprise Series Software Packages

Replace xx in the catalog number with the appropriate language designation ZH=Chinese EN=English FR=French DE=German IT=Italian JP=Japanese KO=Korean PT=Portuguese and ES=Spanish

For upgrades from one package to another see the StepForward program

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Logix5000 controllers supported

All(2) CompactLogixFlexLogix

CompactLogixFlexLogix

All All All(3) All

Relay ladder diagram editor(4)

Uploaddownload and view

Full support Full support Full support Full support Full support Full support

Function block diagram9324-RLDFBDENE(

4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE(4)(5)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Structured text9324-RLDSTXE(4)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Uploaddownload

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

GuardLogix Safety9324-RLDGLXE(6)

Uploaddownload and view

UploaddownloadAvailable separately

Full support UploaddownloadAvailable separately

UploaddownloadAvailable separately

Full support Full support

Highly integrated motion

Uploaddownload and view

Uploaddownload

Full support Full support Full support Full support Full support

Graphical trending Full support Full support(7) Full support(7) Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately

Available separately

Available separately

Included Included Included Included

38 Publication 1756-SG001P-EN-P - May 2011

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

PIDE Autotune9323-ATUNEENE(8)

Available separately

Available separately

Available separately

Available separately

Available separately

Included Included

Advanced Process Control instructions 9324-RLDAPCENE9324-RLDAPCCLENE(9)

Uploaddownload and view

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Routine source protection

Included Included Included Included Included Included Included

RSLogix 5000 project compare

Included Included Included Included Included Included Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) Service Edition supports controllers with firmware revision 12 and later

(3) Full Edition supports controllers with firmware revision 10 and later

(4) A multiple language editor package is available as catalog number 9324-RLDMLPE It contains the function block sequential function chart and structured text editors

(5) The Structured Text editor option (catalog number 9324-RLDSTXE) is required to program SFC actions in structured text

(6) As of RSLogix 5000 programming software version 16

(7) As of RSLogix 5000 programming software version 15

(8) PIDE Autotune is supported on 1769-L23x controllers as of RSLogix 5000 programming software version 18

(9) Select catalog number 9324-RLDAPCENE for a design license for software and a runtime license for one controller Select catalog number 9324-RLDAPCLENE for only a runtime license for one controller (for pay to deploy)

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1)

9324-RLD700NXxxF

Publication 1756-SG001P-EN-P - May 2011 39

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

RSLogix 5000 Integration with Other Applications

Available Features

Service Edition 9324-RLD000xxE

Mini Edition 9324-RLD200xxE

Lite Edition 9324-RLD250xxE

Standard Edition Node Locked 9324-RLD300xxEConcurrent License(1) 9324-RLD300xxF

Standard RSNetWorx Edition 9324-RLD300NXxxE

Full Edition Node Locked 9324-RLD600xxEConcurrent License(1) 9324-RLD600xxF

Professional Edition Node Locked 9324-RLD700NXxxEConcurrent License(1) 9324-RLD700NXxxF

RSLinx Classic software

Lite included Lite included Lite included Lite included Lite included Lite included Lite included

RSNetWorx ControlNetRSNetWorx DeviceNetRSNetWorx EtherNetIP software(2)

Available separately

Available separately

Available separately

Available separately

Included Available separately

Included

FactoryTalk AssetCentre audit support

Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE(3)

NA Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

RSLogix Emulate 50009310-WED200ENE(4)

Available separately

NA NA Available separately

Available separately

Available separately

Included

FactoryTalk Security server(5)

Included Included Included Included Included Included Included

Security server emulator(5)

Included Included Included Included Included Included Included

RSLogix Architect9326-LGXARCHENE(6)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

FactoryTalk View SE demo(50 tags2 hours)

Available separately

Available separately

Available separately

Available separately

Available separately

Available separately

Included

(1) As of RSLogix 5000 programming software version 16 The software is designed to grab the highest functionality license first For example if Standard Full and Professional Concurrent licenses are available on the FactoryTalk Activation server RSLogix 5000 software will grab the highest functionality license first

(2) RSNetWorx for ControlNet software is catalog number 9357-CNETL3 RSNetWorx for DeviceNet software is catalog number 9357-DNETL3 RSNetWorx for EtherNetIP software is catalog number 9357-ENETL3 They are available together as catalog number 9357-ANETL3

(3) As of RSLogix 5000 programming software version 16

(4) RSLogix Emulate 5000 software does not support the Microsoft Windows Vista operating system at this time

(5) FactoryTalk Automation Platform install required - included on disk

(6) As of RSLogix 5000 programming software version 15

40 Publication 1756-SG001P-EN-P - May 2011

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

Notes

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU ltFEFF00560065007200770065006e00640065006e0020005300690065002000640069006500730065002000450069006e007300740065006c006c0075006e00670065006e0020007a0075006d002000450072007300740065006c006c0065006e00200076006f006e002000410064006f006200650020005000440046002d0044006f006b0075006d0065006e00740065006e002c00200076006f006e002000640065006e0065006e002000530069006500200068006f00630068007700650072007400690067006500200044007200750063006b006500200061007500660020004400650073006b0074006f0070002d0044007200750063006b00650072006e00200075006e0064002000500072006f006f0066002d00470065007200e400740065006e002000650072007a0065007500670065006e0020006d00f60063006800740065006e002e002000450072007300740065006c006c007400650020005000440046002d0044006f006b0075006d0065006e007400650020006b00f6006e006e0065006e0020006d006900740020004100630072006f00620061007400200075006e0064002000410064006f00620065002000520065006100640065007200200035002e00300020006f0064006500720020006800f600680065007200200067006500f600660066006e00650074002000770065007200640065006e002egt ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE ltFEFF0041006e007600e4006e00640020006400650020006800e4007200200069006e0073007400e4006c006c006e0069006e006700610072006e00610020006f006d002000640075002000760069006c006c00200073006b006100700061002000410064006f006200650020005000440046002d0064006f006b0075006d0065006e00740020006600f600720020006b00760061006c00690074006500740073007500740073006b0072006900660074006500720020007000e5002000760061006e006c00690067006100200073006b0072006900760061007200650020006f006300680020006600f600720020006b006f007200720065006b007400750072002e002000200053006b006100700061006400650020005000440046002d0064006f006b0075006d0065006e00740020006b0061006e002000f600700070006e00610073002000690020004100630072006f0062006100740020006f00630068002000410064006f00620065002000520065006100640065007200200035002e00300020006f00630068002000730065006e006100720065002egt ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

Notes

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Publication 1756-SG001P-EN-P - May 2011 44Supersedes Publication 1756-SG001O-EN-P - October 2010 Copyright copy 2011 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products At httpwwwrockwellautomationcomsupport you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make thebest use of these tools

For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit httpwwwrockwellautomationcomsupport

Installation Assistance

If you experience a problem within the first 24 hours of installation review the information that is contained in this manualYou can contact Customer Support for initial help in getting your product up and running

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures

Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA-DU002 available at httpwwwrockwellautomationcomliterature

United States or Canada 14406463434

Outside United States or Canada

Use the Worldwide Locator at httpwwwrockwellautomationcomsupportamericasphone_enhtml or contact your local Rockwell Automation representative

United States Contact your distributor You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process

Outside United States Please contact your local Rockwell Automation representative for the return procedure

Allen-Bradley Rockwell Automation Rockwell Software ArmorBlock Guard IO CompactBlock Guard IO CompactLogix ControlLogix ControlLogix-XT Data Highway Plus DH+ DriveExecutive Encompass FactoryTalk View FactoryTalk View SE FactoryTalk Activation FactoryTalk Security FactoryTalk AssetCentre FactoryTalk Automation Platform FLEX Ex FLEX IO FLEX IO-XT FlexLogix Guard IO GuardLogix Kinetix KwikLink Logix5000 MicroLogix NetLinx PanelView PanelView Plus PanelView Plus CE PLC-5 PhaseManager POINT Guard IO PowerFlex PowerFlex 70 PowerFlex 755 PowerFlex 700S Powermonitor 3000 RSFieldbus RSLinx RSLogix 5000 RSLogix Architect RSLogix Emulate 5000 RSNetWorx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNetIP SLC SLC 500 SoftLogix Stratix 8000 SynchLink Ultra3000 Ultra5000 1336 Plus II and TechConnect are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • 1756-SG001P-EN-P ControlLogix System Selection Guide
  • ControlLogix System Overview
    • Example Configuration - ControlLogix System
    • ControlLogix-XT System
    • GuardLogix Safety System
    • Example Configuration - Redundant ControlLogix System
    • Example Configuration - Redundant IO System
      • ControlLogix IO Modules
        • AC Digital put Modules
        • AC Digital Output Modules
        • DC Digital Input Modules
        • DC Digital Output Modules
        • Contact Output Modules
        • Analog Input Modules
        • Analog RTD and Thermocouple Modules
        • Analog Output Modules
        • Analog Combination Input and Output Module
        • Specialty IO Modules
          • HART Smart Instrumentation
            • Typical HART Configuration
            • HART Interfaces
            • Accessories - IO Modules
              • ControlLogix Integrated Motion
                • Integrated Motion on an EtherNetIP Network
                • SERCOS Interface Modules
                • Analog Motion Interface Modules
                  • ControlLogix Communication Modules
                    • EtherNetIP Communication Modules
                    • Accessories - EtherNetIP Network
                    • Example Configuration - EtherNetIP Network
                    • ControlNet Communication Modules
                    • Example Configuration - ControlNet Network
                    • Example Configuration - Redundant ControlNet Media
                    • DeviceNet Communication Module
                    • Example Configuration - DeviceNet Network
                    • Accessories - DeviceNet Network
                    • Data Highway Plus and Remote IO Communication Modules
                    • Example Configuration - DH+ Network
                    • Example Configuration - Remote IO Network
                    • Accessories - DH+ and Remote IO Networks
                    • FOUNDATION Fieldbus Linking Devices
                    • Example Configuration - Bridge to EtherNetIP Network
                    • Example Configuration - Bridge to ControlNet Network
                    • Other Connectivity Options
                      • ControlLogix Controllers
                        • Standard ControlLogix Controllers
                        • GuardLogix Controllers
                        • ControlLogix-XT Controllers
                        • Redundant ControlLogix Controllers
                        • Accessories - Controllers
                          • ControlLogix Chassis
                            • Features - Chassis
                            • Standard Chassis
                            • ControlLogix-XT Chassis
                            • Accessories - Chassis
                              • ControlLogix Power Supplies
                                • Standard Power Supplies
                                • ControlLogix-XT Power Supplies
                                • Redundant Power Supplies
                                • Accessories - Redundant Power Supplies
                                  • Visualization Products
                                  • Programming Software
                                    • 1756 System Software
                                    • RSLogix 5000 Programming Software
                                    • RSLogix 5000 Enterprise Series Software Packages
                                      • Back Cover
                                        • Introduction_Catagory Types

                                          Print Spec Sheet

                                          ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB ltFEFF005500740069006c0069007a006500200065007300730061007300200063006f006e00660069006700750072006100e700f50065007300200064006500200066006f0072006d00610020006100200063007200690061007200200064006f00630075006d0065006e0074006f0073002000410064006f0062006500200050004400460020007000610072006100200069006d0070007200650073007300f5006500730020006400650020007100750061006c0069006400610064006500200065006d00200069006d00700072006500730073006f0072006100730020006400650073006b0074006f00700020006500200064006900730070006f00730069007400690076006f0073002000640065002000700072006f00760061002e0020004f007300200064006f00630075006d0065006e0074006f00730020005000440046002000630072006900610064006f007300200070006f00640065006d0020007300650072002000610062006500720074006f007300200063006f006d0020006f0020004100630072006f006200610074002000650020006f002000410064006f00620065002000520065006100640065007200200035002e0030002000650020007600650072007300f50065007300200070006f00730074006500720069006f007200650073002egt SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                          JIT Printing Specifications RA-QR005E-EN-P - 5192009
                                          Printing Specification YOUR DATA HERE Instructions NO
                                          (required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                          (required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                          (required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
                                          Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                          Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
                                          Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
                                          (required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
                                          (required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
                                          BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                          (required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
                                          Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
                                          Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
                                          Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
                                          Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
                                          Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
                                          Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
                                          Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
                                          Comments C2
                                          Part Number none JIT POD
                                          D1
                                          D2
                                          D3
                                          D4
                                          D5
                                          D6
                                          D7
                                          D8
                                          D9
                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                          Publication Type and Print Category
                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                          News Release (press releases should not be checked into DocMan or printed)
                                          AT B3 B4 D5 Application Techniques 5 100 Presale External
                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                          CG NA NA Catalogue Guide 1 50 Presale External
                                          CL NA NA Collection 5 50 Presale External
                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                          DM NA NA Product Demo 5 50 Presale Internal
                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                          DU B3 D5 Document Update 1 5 Post External
                                          GR B2 D6 Getting Results 1 5 Post External
                                          IN B3 D5 Installation instructions 1 5 Post External
                                          LM NA NA Launch KitMaterials 5 50 Presale Internal
                                          PC B3 D5 Packaging Contents
                                          PL E-only Primary B3 E-only Price List 5 50 Presale Internal
                                          PM B2 D6 Programming Manual 1 5 Post External
                                          PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                          QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                          QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                          RN B3 D5 Release Notes 1 5 Post External
                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                          SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                          Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
                                          A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
                                          A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
                                          A4 2 color 80 gloss cover 80 gloss text
                                          170gsm Silk ndash 120gsm Silk
                                          A5 2 color 80 gloss cover 80 matt sheet text
                                          170gsm Silk ndash 120gsm Silk
                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                          A7 4 color cover 10 Point Cover C2S
                                          2 color text Category being deleted 50 matte sheet text
                                          Selection Guide
                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                          2 color text
                                          Selection Guide
                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                          Selection Guide
                                          Post Sale Technical Communication
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                          2 color text 50 matte sheet text
                                          B2 1 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B3 1 color 50 matte sheet text self cover
                                          100gsm bond
                                          B4 2 color 60 Cover
                                          160gsm Colortech amp 100gsm Bond 50 matte sheet text
                                          B5 2 color 50 matte sheet text self cover
                                          100gsm bond
                                          Catalogs
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                          4 color text 45 Coated Sheet
                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                          2 color text 32-33 Coated Sheet
                                          JIT POD
                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                          D4 1 color 160gsm tab 90 index
                                          D5 1 color 80gsm bond 20 bond self cover
                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D7 2 color 160gsm tab 90 index
                                          D8 2 color 80gsm bond 20 bond self cover
                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

Introduction_Catagory Types

Print Spec Sheet

ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN ltFEFF004200720075006700200069006e0064007300740069006c006c0069006e006700650072006e0065002000740069006c0020006100740020006f007000720065007400740065002000410064006f006200650020005000440046002d0064006f006b0075006d0065006e007400650072002000740069006c0020006b00760061006c00690074006500740073007500640073006b007200690076006e0069006e006700200065006c006c006500720020006b006f007200720065006b007400750072006c00e60073006e0069006e0067002e0020004400650020006f007000720065007400740065006400650020005000440046002d0064006f006b0075006d0065006e0074006500720020006b0061006e002000e50062006e00650073002000690020004100630072006f00620061007400200065006c006c006500720020004100630072006f006200610074002000520065006100640065007200200035002e00300020006f00670020006e0079006500720065002egt DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

JIT Printing Specifications RA-QR005E-EN-P - 5192009
Printing Specification YOUR DATA HERE Instructions NO
(required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
(required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
(required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
(required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
(required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
(required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
Comments C2
Part Number none JIT POD
D1
D2
D3
D4
D5
D6
D7
D8
D9
This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
Publication Type and Print Category
Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
AR NA NA ArticleEditorialByline NA NA Presale Internal
News Release (press releases should not be checked into DocMan or printed)
AT B3 B4 D5 Application Techniques 5 100 Presale External
BR A2 Primary A1 NA Brochures 5 100 Presale External
CA C2 Primary C1 NA Catalogue 1 50 Presale External
CG NA NA Catalogue Guide 1 50 Presale External
CL NA NA Collection 5 50 Presale External
CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
CP E-only E-only D5 Competitive Information 5 50 NA Confidential
DC E-only E-only Discount Schedules NA NA Presale Internal
DI A1 A3 NA Direct Mail 5 100 Presale Internal
DM NA NA Product Demo 5 50 Presale Internal
DS B3 D5 Dimensions Sheet 1 5 Post External
DU B3 D5 Document Update 1 5 Post External
GR B2 D6 Getting Results 1 5 Post External
IN B3 D5 Installation instructions 1 5 Post External
LM NA NA Launch KitMaterials 5 50 Presale Internal
PC B3 D5 Packaging Contents
PL E-only Primary B3 E-only Price List 5 50 Presale Internal
PM B2 D6 Programming Manual 1 5 Post External
PP A3 D1 Product Profile NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
QR B2 Primary B3 B5 D5 D6 Quick Reference 1 5 Post External
QS B2 Primary B3 B5 D5 D6 Quick Start 1 5 Post External
RM B2 D5 D6 Reference Manual 1 5 Post External
RN B3 D5 Release Notes 1 5 Post External
SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
SG B2 D5 D6 Selection Guide BW 5 50 Presale External
SP A1 A2 A3 A4 NA Service ProfileSales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
UM B2 Primary B4 D6 User Manual BW 1 5 Post External
WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
WP B3 Primary B5 D5 White Paper 5 50 Presale External
Pre-sale Marketing All paper in this category is White Brightness 85 or better Opacity 87 or better
Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
A1 4 color 170gsm 2pp 100 gloss cover 100 gloss text
A2 4 color 170gsm folded 4pp 100 gloss cover 80 gloss text
A3 4 color Cover 170gsm with Body 120gsm gt 4pp 80 gloss cover 80 gloss text
A4 2 color 80 gloss cover 80 gloss text
170gsm Silk ndash 120gsm Silk
A5 2 color 80 gloss cover 80 matt sheet text
170gsm Silk ndash 120gsm Silk
A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
A7 4 color cover 10 Point Cover C2S
2 color text Category being deleted 50 matte sheet text
Selection Guide
A8 4 color cover Category being deleted 50 matte sheet text self cover
2 color text
Selection Guide
A9 2 color 100gsm bond 50 matte sheet text self cover
Selection Guide
Post Sale Technical Communication
Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
2 color text 50 matte sheet text
B2 1 color 60 Cover
160gsm Colortech amp 100gsm Bond 50 matte sheet text
B3 1 color 50 matte sheet text self cover
100gsm bond
B4 2 color 60 Cover
160gsm Colortech amp 100gsm Bond 50 matte sheet text
B5 2 color 50 matte sheet text self cover
100gsm bond
Catalogs
Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
4 color text 45 Coated Sheet
C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
2 color text 32-33 Coated Sheet
JIT POD
Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
D4 1 color 160gsm tab 90 index
D5 1 color 80gsm bond 20 bond self cover
D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
D7 2 color 160gsm tab 90 index
D8 2 color 80gsm bond 20 bond self cover
D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond

Print Spec Sheet

ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 14 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth 8 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter FlateEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth 8 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter FlateEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE ltFEFF0041006e007600e4006e00640020006400650020006800e4007200200069006e0073007400e4006c006c006e0069006e006700610072006e00610020006f006d002000640075002000760069006c006c00200073006b006100700061002000410064006f006200650020005000440046002d0064006f006b0075006d0065006e00740020006600f600720020006b00760061006c00690074006500740073007500740073006b0072006900660074006500720020007000e5002000760061006e006c00690067006100200073006b0072006900760061007200650020006f006300680020006600f600720020006b006f007200720065006b007400750072002e002000200053006b006100700061006400650020005000440046002d0064006f006b0075006d0065006e00740020006b0061006e002000f600700070006e00610073002000690020004100630072006f0062006100740020006f00630068002000410064006f00620065002000520065006100640065007200200035002e00300020006f00630068002000730065006e006100720065002egt ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

JIT Printing Specifications RA-QR005E-EN-P - 5192009
Printing Specification YOUR DATA HERE Instructions NO
(required) Category D5 Select Print Category ABC or D from category list on Introduction_Catagory Types tab 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
(required) Finished Trim Size Width 85rdquo x 11rdquo 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
(required) Publication Number 1756-SG001P-EN-P Sample 2030-SP001B-EN-P 3rdquo x 5rdquo SADDLE - Saddle Stitch A2 RIGHT CORNER
Use Legacy Number NO YES or NO 18rdquo x 24rdquo Poster PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
Legacy Number if applicable Sample Legacy Number 0160-533 24rdquo x 36rdquo Poster STAPLED1 -1 position A3
Publication Title ControlLogix Selection Guide Sample ElectroGuard Selling Brief 36rdquo x 24rdquo Poster STAPLED1B - bottom 1 position A5
(required) Business Group Marketing Commercial As entered in DocMan 4rdquo x 6rdquo STAPLED2 - 2 positions A6
(required) Cost Center CMKMAY IA ControlVisNet - 19021 As entered in DocMan - enter number only no description Example - 19021 CMKMKE CM Integrated Arch - 19021CMKMKE Market Access Program - 19105 475rdquo x 7rdquo (slightly smaller half-size) THERMAL - Thermal bound (Tape bound) A7
BindingStitching SADDLE - Saddle Stitch Review key on right Saddle-Stitch Items All page quantities must be divisible by 420 sheets max on 20 (text and cover) 20 sheets = 80-page pub16 sheets max on 20 (text) and 90 (cover) 16 sheets = 64-page pubPerfect Bound Items475 sheets max on 20 no cover 475 sheets = 950-page pub470 sheets max wcover 90 index unless indicated otherwise) 470 sheets = 940-page pubCoil Bound Items400 sheets max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 400 sheets = 800-page pubTape Bound Items125 sheets max on 20 no cover 125 sheets = 250-page pub120 sheets max wcover (90 index unless indicated otherwise) 120 sheets = 240-page pubDouble Wire Bound Items250 sheets max on 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise) 250 sheets = 500-page pub 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
(required) Page Count of Publication 44 Total page count including cover 55rdquo x 85rdquo (half-size) Wire O - Double Wire Bound (offline) A9
Paper Stock Color white White is assumed For color options contact your vendor 6rdquo x 4rdquo Post Sale Technical Communication
Number of Tabs Needed 0 5 tab in stock at RR Donnelley 7385rdquo x 9rdquo (RSI Std) B1
Stitching Location SIDE Blank Corner or Side 825rdquo x 10875rdquo B2
Drill Hole YESNO YES All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border 825rdquo x 11rdquo (RA product profile std) B3
Glue Location on Pad Glue location on pads 8375rdquo x 10875 B4
Number of Pages per Pad Average sheets of paper 25 50 75100 Max 9rdquo x 12rdquo (Folder) B5
Ink Color One color assumes BLACK 4 color assume CMYK Indicate PMS number herehellip A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) Catalogs
Used in Manufacturing NO A5 (583rdquo x 826rdquo) (148 x 210 mm) C1
Comments C2
Part Number none JIT POD
D1
D2
D3
D4
D5
D6
D7
D8
D9