1700 shielded rooms

2
Due to increased Electro Magnetic pollution, sensitive and accurate measurements are often affected by RF noise. The application of Comtest Shielded Rooms provides the highest shielding attenuation, creating a well protected and quiet environment to execute instrument calibrations and highly sensitive measurements. Application of Shielded Rooms can also be found in standard instrument calibration laboratories, security environments as well as in hospitals . Shielded Rooms Model 1700 Comtest Engineering BV Industrieweg 12 - NL-2382 NV Zoeterwoude - The Netherlands. T: +31-(0)71-5417531 - F: +31-(0)71-5420375 - @: [email protected] - www.comtest.eu Today’s electronic manufacturer needs more than just a production line. EMC requirements demand advanced development and test facilities, as well as the knowledge to design and implement effective EMC requirements. Since sophisticated electronics permeate modern life, carefully controlled electromagnetic environ- ments become essential. Shielded rooms and architectural shielding are an integral component in modern facility designs. Communication centers, Calibration and EMC laboratories, Hospitals and many other facilities all require electromagnetic shielding. • Wide choice of swing and sliding doors, both manual, semi and full automatic operation • In house design and production of shielded panels, doors etc. • Experienced engineering team for shielding and EMC facility technology • Service and maintenance contracting. Benefits • Flexible design for small enclosures up to large facilities • Use of 2 mm modular ZMA-140 folded panels • Self supporting construction of enclosures up to 4m length or width • Various applications such as calibration chambers, military and hospital environment as well as EMC facilities • Turnkey design and installation Features

Upload: bal3x

Post on 02-May-2017

238 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 1700 Shielded Rooms

Due to increased Electro Magnetic pollution, sensitive and accurate measurements are often affected by RF noise. The application of Comtest Shielded Rooms provides the highest shielding attenuation, creating a well protected and quiet environment to execute instrument calibrations and highly sensitive measurements.Application of Shielded Rooms can also be found in standard instrument calibration laboratories, security environments as well as in hospitals .

Shielded Rooms

Model 1700

Comtest Engineering BVIndustrieweg 12 - NL-2382 NV Zoeterwoude - The Netherlands.T: +31-(0)71-5417531 - F: +31-(0)71-5420375 - @: [email protected] - www.comtest.eu

Today’s electronic manufacturer needs more than just a production line. EMC requirements demand advanced development and test facilities, as well as the knowledge to design and implement effective EMC requirements.Since sophisticated electronics permeate modern life, carefully controlled electromagnetic environ-ments become essential.Shielded rooms and architectural shielding are an integral component in modern facility designs. Communication centers, Calibration and EMC laboratories, Hospitals and many other facilities all require electromagnetic shielding.

• Wide choice of swing and sliding doors, both manual, semi and full automatic operation• In house design and production of shielded panels, doors etc.• Experienced engineering team for shielding and EMC facility technology• Service and maintenance contracting.

Benefits• Flexible design for small enclosures up to large facilities• Use of 2 mm modular ZMA-140 folded panels• Self supporting construction of enclosures up to 4m length or width• Various applications such as calibration chambers, military and hospital environment as well as EMC facilities• Turnkey design and installation

Features

Page 2: 1700 Shielded Rooms

The Comtest Shielded Rooms, model 1700-000 takes advantage of their flexible design. Following items can be included upon customer request:• Swing doors, 1766-series• Sliding doors, 1752-series• Honey combs, 1791/1792-series• Main power line filters, 4800/4900 series• Shielded windows, 2800 series• Entry panels, 1795-series• Data communication filters, 4700-series.

In addition to our standardized models all chambers are available in customized dimensions to satisfy ourcustomers’ individual requirements.

Comtest Engineering BVIndustrieweg 12 - NL-2382 NV Zoeterwoude - The Netherlands.T: +31-(0)71-5417531 - F: +31-(0)71-5420375 - @: [email protected] - www.comtest.euAll specifications subject to change without prior notice. Printed in The Netherlands. (rev. 1.0, March 2010)

Shielded Rooms

Model 1700

COMTEST are dedicated to provide its customers with a complete solution and the latest products that meet their requirements. Through a network of qualified distributors in Europe, USA and Asia, COMTEST is able to supply a full range of products and services including:

✓ Shielding enclosures ✓ Turnkey project management✓ Worldwide service support✓ Maintenance contracts✓ Consultancy services✓ EMC training✓ System integration✓ Application software✓ Acceptance and pre-compliance EMC testing

For detailed information and latest update of our products visit www.comtest.eu

Specifications Shielding Performance(IEEE-299 / EN 50147-1)

Typical Performance

Atte

nuat

ion

(dB

)0

20

40

60

80

100

120

140

1kHz 10kHz 100kHz 1Mhz 10MHz 100MHz 1GHz 10GHz 40GHz

Frequency

Magnetic fieldElectric fieldPlane Wave