Gas boilers
E D E N A P r o g r e s s : t h e b e s t s uEDENA PROGRESS
2
EDEN
A EDENA PROGRESS IS THE NEWGENERATION OF EDENA BOILERS. ITSWIDE RANGE GIVES IT UNRIVALLEDADAPTABILITY FOR ALL REQUIREMENTS.ROUND ITS FAMOUS CAST IRON HEATINGBODY THIS NEW BOILER TAKESADVANTAGE OF THE LATEST CHAPPEEINNOVATIONS ESPECIALLY INMATERIALS, REGULATION AND EASE OFINSTALLATION.
tried and tested heating body;adaptability of chimney or fluemodels;instructions very simple;total safety;savings thanks to low temperatureoperation;highly adaptable with its wealth ofhot water solutions;unbelievably easy to install withCHAPPÉE kits;new design with pure lines;delivered in 2 “pre-lined” packagesfor hot water models.
UNRIVALLEDADAPTABILITY
The EDENA Progress range is one ofthe richest and most innovative onthe heating and hot waterproduction market. Available in theheating only version, with built intank on top or at the side, naturalgas chimney (LE, LEB), all gas (SE,SEB) or the flue version (FF, FFB),EDENA Progress stands with bliss inall places even the mostdemanding.Its white colour and compact size
even allow it to findits place in kitchens.4 powers for chimneyonly heating models:16 to 32 kW and threepowers for all othermodels 24, 28 and32 kW allow it to meetall requirements ofmost accommodation.All these boilers can bevery easily fittedthanks to the built inhydraulics and CHAPPÉEmodules kit.
n s h i n e , e v e n m o r e p r o g r e s sEDENA PROGRESS
3
Stainless steelburner
Gas valve withbuilt in control
50 mm glass woolinsulation
Polyurethaneinsulating shell
Fan
Hydraulic module(option)
Low spiralenamelled heatexchanger
10 litre expansiontank (option)
Cast iron heatexchanger with
profiled fins
Aluminium cover
Control panel
Electronicignition
Load pump
Inspection flapwith checkable
anode
EDENA Progress FFB boiler cut away section
E D E N A P r o g r e s s : t h e b e s t s uEDENA PROGRESS
4
QUALITIES OF FLUE MODELS
There are no more constraints linked to chimneys:the nonexistent duct, deteriorated chimneys oreven those that are no longer equivalent to thefeatures of power required for a new plantincorporating hot water for example.Installation costs are reduced; a flue system iseasily and quickly fitted and everywhere through awall or roof.Maintenance costs are reduced since the chimneydoes not have to be swept anymore. The safetyprovided by sealed combustion circuit is total; airis sampled outside and there is no risk of smokeblowback inside.
PROGRESS DESIGN
EDENA Progress is a user friendly welcomingboiler. It is attractive with its curvy linesharmonising with the advanced design trends ofCHAPPÉE. Its pure white colour enables it toeasily integrate with the house. Its clear simple control panel is protected by analuminium cover. It integrates regulation as wellas its operating instructions, so always withinreach.The luminous diode indicators for correctoperation can be read once the cover is closed.No more than 1.5 m high the compact shape ofthe B model is surprising.
STRONG POINTS FOR KEEPING WARM
First the ignition: it is electronic, easy to use,perfectly tuned and secure. The burner on theLE models is designed for reducing NOx and COpollution even more.The heating body is cast iron, so very solid, andhas a high water capacity. It is insulated with a50 mm layer of glass wool. All these strong pointscontribute to the image of reliability of CHAPPÉEboilers and are also savings generators. The proof:EDENA has a high 92% output and is classed LowTemperature according to the RT 2000 regulations.
n s h i n e , e v e n m o r e p r o g r e s sEDENA PROGRESS
THE BLISS OF HOT WATER
120 litres of hot water reheated in 10 minutes,and the bliss of plentiful hot water all the time atconstant temperature for the whole family. Thepower of the heat exchanger (27 kW) in fact makesit possible to provide hot water at will at 40°Cwith 230 litres flow in 10 minutes. The water tankcompletely built into the boiler on the B models orside by side is kept hot in a moulded polyurethaneshell to prevent any heat bridge. Inside it isenamelled to protect it thoroughly from anycorrosion; the low curves of the coil and chromefree enamel guarantee perfect hygiene.Maintenance is problem free with its very largeinspection trap (125 diameter) and magnesiumanode providing additional safety. Besides themodels with built in and side by side tanks (AB),CHAPPÉE is offering a horizontal version under theboiler (150 litres HB) and a cylindrical range (150to 200 litres CD).
Characteristics of the DHW tankAccording to RT 2000
5
Quick selection method (reserved for individual use)PIM AB Plant
Levels of use and built in PIM HB PIM CB120 l 150 l 150 l 200 l1 bath 1 luxurious bath 1 luxurious bath
COMFORTand 1 shower and 1 douche and 1 shower
2 baths
1 bath 1 bath 1 bathGREAT COMFORT
or 2 showers and 1 shower and 1 shower2 baths
1 bath 1 bathINTENSIVE -
or 2 showers or 2 showers2 baths
* Hot water at 40°C cold water 10°C.** According to EN 303.6 on 32 model.
EDENA FF/FFB LE/LEB SE/SEBModel B and AB B BStorage capacity l 120 120 120Heating surface m2 0.97 0.97 0.97Storage temperature °C 60 60 60Required flow in 10 minutes* l 230 230 230Required continuous flow
t = 30 K l/h 830 830 830Reheating time mn 15 15 15Cooling constant Wh/l/°C/day 0.38 0.38 0.38Nominal power** kW 28.7 28.7 28.7Room temperature at NP °C 20 20 20Max domestic operating pressure bar 7 7 7Auxiliary electric power(DHW pump) W 114 114 114
New PIM AB
E D E N A P r o g r e s s : t h e b e s t s uEDENA PROGRESS
6
THE CONTROL PANEL
Positioned at a good height and sloping for easyuse, it shall be made to measure according toregulation requirements with the appropriatecomfort module. The simplified operatinginstructions are within reach on the control panel.
Basic moduleIt incorporates the main boiler instructions as wellas the control and operating indicators.
Comfort modulesThe choice of a comfort module is required forensuring EDENA Progress operation and controlunder the best conditions of ease for energysavings and comfort. All models in the ECOCONTROLrange are easily integrated in the control panelaccording to the desired price and comfort level.All regulators are delivered preset according to analways accessible standard programme.ECOCONTROL SP regulators controlheating and domestic hot water production(each ECOCONTROL SP box is delivered with awater temperature measuring probe).
ECOCONTROL SP OB version 5This is an electronic module controlling the boilerand managing hot water priorities when installingcomfort regulation is not wanted. Boilertemperature is chosen manually.
12
9 10 118
3 4 5 76
2
13 14
16 1715
ECOCONTROL SP OB comfort module.
Basic module.
1 Prewired housing forcomfort module of choice
2 Thermometer3 Overheating safety
thermostat4 Thermostat testing button5 Burner reset button6 Boiler switch7 Fuse8 Overheating safety indicator9 Burner operating indicator10 Burner safety indicator
11 On indicator12 SUMMER/WINTER switch13 Heating thermostat14 Hot water thermostat15 Heating on indicator16 Probe fault indicator17 Domestic water on indicator
1
n s h i n e , e v e n m o r e p r o g r e s sEDENA PROGRESS
7
REGULATORS
How to choose the regulatorIt is very easy to choose an ECOCONTROL SPregulator: you have to fix its programmingprinciple according to its life style, and sopredictable times when the heated room will beoccupied. The regulator model is selectedaccording to the features of its installation:radiator, low temperature, underfloor heating,separate heating areas (2 apartments), or onefurnished with radiators, and the other underfloorheating.
ECOCONTROL SP 1 daily programming• Life style: identical predictable tempo every day
of the week (including the weekend).The regulator is programmed to raise or lowerthe temperature according to a timetableselected by the user. Introduction of the “clock”type benefited touch instruction for fans of dialsand needles;
• features of heating plants with or withoutdomestic hot water:- single radiator system with burner control
• main advantages: ease of setting.
ECOCONTROL SP 2, 3, 4 daily or weeklyprogramming• Life style: different tempo and activities
according to the days of the week. Suits activityusers or business premises especially.
Introduction of “digital” type benefits comfortinstructions and information on screens, etc.
• Features of heating and domestic hot waterplants: - single radiator system with burner control(ECOCONTROL SP 2);
- system of low temperature radiators orunderfloor heating with control of 3 way valveand burner (ECOCONTROL SP 3).
- 2 systems of independent low temperature (orunderfloor heating) radiators control of burnerand 2 three way valves (ECOCONTROL SP 4).
• Remote control and programming ofECOCONTROL SP 2, 3 and 4 (as option).
Selection table
ECOCONTROL SP OB version aThe electronic module is assisted by anECOCONTROL programmable ambience thermostat.
Ambience thermostat for SP OBa.
TYPE OF REGULATORModels ManualECOCONTROL SP
Acting on burner ECOCONTROL SP ECOCONTROL SP ECOCONTROL SP ECOCONTROL SPOB s OB a 1a analogue 1a analogue
ECOCONTROL SP ECOCONTROL SP2s digital 2s digital
Acting on burner ECOCONTROL SP ECOCONTROL SPand valve 3s 3aActing on burner ECOCONTROL SP ECOCONTROL SPand 2 valves 4s 4a
1
2
3
45678
1 Key for settinginstruction values,time and switchingtimes
2 Operating rateselector
3 Day of the weeksetting
4 Real time setting5 Selection and exit
from switchingsetting
6 Instruction valuesetting for Economyoperating
7 Instruction valuesetting for Comfortoperating
8 Validating key forprogrammeswitching settings.
ECO- Burner Burner and twoCONTROL Burner 3 way valve and 3 way valve 3 way valvesSP OB Radiator
Radiator Low temperatureSP 1 radiator or
underfloor heating
SP 2 Radiator
SP 3 Radiator and lowtemperature radiatoror underfloor heating
SP 4 Radiator and low 2 low temperaturetemperature radiator radiators systemor underfloor heating or mixer with
underfloor heating
EDENA PROGRESS
8
Daily programming
ECOCONTROL SP 1
Intended for: individual heating. Plant comprisingone single heating area with or without built inhot water production or connected to the CHAPPÉEboiler.Installation: radiators with burner and lowtemperature radiators control.
Weekly or daily programming
ECOCONTROL SP 2
Intended for: individual heating. Installationcomprising one single heating area with or withoutbuilt in hot water production or connected to theCHAPPÉE boiler.Installation: radiators with burner control.
ECOCONTROL SP 3
Intended for: individual heating. Installationcomprising one single heating area with or withoutbuilt in hot water production or connected to theCHAPPÉE boiler.Installation with radiators, low temperatureradiators or underfloor heating with burner andvalve control.
ECOCONTROL SP 4
Intended for: the ECOCONTROL SP 4’s speciality isits capacity to control 2 completely independentheating areas, for example 1 area with underfloorheating + 1 area with radiators, 2 radiator areas,2 underfloor heating areas or 2 separateapartments. Hot water production may be built inor connected to the boiler.Installation with radiators, low temperatureradiators or underfloor heating, air heaters, hotwater convector with burner and 2 valves control.
Digital screen weekly programming
Remote controlDigital screen weekly programming of allregulation functions. The QAA 70 programmer isfor remote control ofCHAPPÉE boilers fitted withECOCONTROL SP 2s, 3s or 4sregulation; that is to say theECOCONTROL SP boxesdelivered with no ambiencesensor. Its control screen isfor displaying alltemperatures, ambient andoutside and hot water as well as operating rates.
Advantages• 3 heating periods per day, everyday of the week
able to be customised;• Plant delivered with standard programming for
fast starting;• Display of temperatures and operating rate.
2
E D E N A P r o g r e s s : t h e b e s t s u
EDENA PROGRESS
9
n s h i n e , e v e n m o r e p r o g r e s s
EDENA HEATING MODULES
Integrated hydraulic kitTo make it easier to install the EDENA in reducedareas or to improve presentation, a kit may bebuilt in the lining. This hydraulic kit comprises a3 speed loading pump, a 10 litre expansion tankthat is located in front of the boiler for easiermaintenance.
1. Heating module for circuit with nomixer valve (ref: 12000201)Intended for: boiler with or without regulatordirectly controlling burner for a radiator circuit.Packaging: delivered in 1 package ref: 12000201(module 1).
2. Heating module for circuit with nomixer valve but with differential valve(ref: 12000202)Intended for: boiler with or without regulatordirectly controlling burner for a radiator circuit.The differential valve balances pressure in theevent of the thermostat valves on the radiatorcircuit closing.Packaging: delivered in 2 packages (1 module 1package ref: 12000201 and 1 differential valvepackage ref: 12000207).
QAA 50 sensor. MT 31 telephoneinterface.
BP 30 sound generator.
Mixing valve package. Outside temperaturesensor.
ECOCONTROL SP connectors.ECOCONTROL SP OBambience thermostat.
REGULATION OPTIONS
Module 1.
Boiler
Example of connection withdifferential valve diagram.
Module 2.
E D E N A P r o g r e s s : t h e b e s t s uEDENA PROGRESS
10
3. Heating module for circuit with 3 wayvalve with no motor (ref: 12000203)Intended for: boiler with or without regulatorcontrolling valve and burner for a radiator circuitor underfloor heating.Packaging: delivered in 1 package ref: 12000203(module 3).
4. Heating module for circuit with 3 wayvalve with no motor and differentialvalve (ref: 12000204)Intended for: boiler with or without regulatorcontrolling valve and burner for 1 radiator circuitwith thermostat valve or underfloor heating.Packaging: delivered in 2 packages (1 module 3package ref: 12000203 and 1 differential valvepackage ref: 12000207).
5. Heating module for 2 circuits withone of them on 3 way valve with nomotor (ref: 12000205)Intended for: boiler with regulator controlling2 circuits, first circuit radiator or underfloorheating, second circuit exclusively radiators withdifferential valve. For one DHW production boilerthis module is for making 2 heating circuits.Packaging: delivered in 4 packages (1 module 1package ref: 12000201, 1 module 3 packageref: 12000203, 1 manifold package ref: 12000208and 1 differential valve package ref: 12000207).
6. Heating module for 2 circuits on two3 way valves with no motor(ref: 12000206)Intended for: boiler with regulator controlling2 circuits, acting on two 3 way valves.Packaging: delivered in 4 packages (2 module 3packages ref: 12000203, 1 manifold packageref: 12000208 and 1 differential valve packageref: 12000207).
Module 3.
Mandatory mixing valve
Boiler
Example of connection layout.
Module 4.
Boiler
Examples of radiator or underfloorheating connection layout.
Module 5.
Boiler
Example of connection layout.
Module 6.
Boiler
Example of connection layout.
n s h i n e , e v e n m o r e p r o g r e s sEDENA PROGRESS
11
7. Valve motor with QAD 21 outputsensor and VFAS (ref: 12000209)
8. Insulated connection piping(ref: 17401530)Intended for: connecting modules below, onEDENA boilers up to 32 kW. These insulated pipesare fitted on the left or right of the boiler.Possibility of connecting the safety module andexpansion tank (not supplied).Packaging: delivered in 2 packages.
9. Safety module (ref: 12000211)Intended for: this insulated module consists of asafety valve, degasser and pressure gauge.The safety valve is fitted on the insulatedconnection pipes. It cannot be fitted separately.
10. Wall bracket (ref: 12000213)
11. ECO heating module(ref: 12000224)The ECO heating module designed for EDENAgroups together all the additional boilercomponents to make a complete installation ofquality and in less time. Intended for: a heating circuit with 3 way valve,fitted on left or right or in double circuit with the2 outputs kit.Packaging: delivered in 1 package: pump, valve,3 way valve, safety valve, pressure gauge, 18 litresexpansion tank, degasser, isolating valves,compression connections, insulated connectionpipes and isolation shell.Option: motor (ref: 12000209)
12. Hydraulic module (ref: 90190025)Module comprising heating pump, expansion tank,valve, pressure gauge, integrable at the front, inthe EDENA jacket.
2 output sensors delivered with all our valvemotors. Piping mounted operation.
Module 3 with valvemotor as option.
Safety module piping.Insulated connection piping of heatingmodule.
Safety module.
ECO heating module with expansion tank built in front face.
Modules ECOCONTROL 1 ECOCONTROL 2 ECOCONTROL 3 ECOCONTROL 41 • •2 • •3 •4 •5 •6 •
ECO module.
Assembled heating module.
E D E N A P r o g r e s s : t h e b e s t s uEDENA PROGRESS
12
BLISS TO BE INSTALLED
The very low model with tank is easily fitted.Hydraulic connections: comprising two outputsand two returns, male ones for heating with one26 x 34 diameter and 20 x 27 tapped female onesfor direct connection of hot water tanks to theboiler.
Electrical installation: a specific connectionterminal is for cabling through the top withoutopening the control panel.
FLUE:LAYOUT RULES
RequirementsA = 0.40 m: Minimum distance from centreline of burnt
gas vent to any hole.
B = 0.60m: Minimum distance from centreline of burntgas vent to any other ventilation hole.
C = 1.80m: Exhaust holes opening directly onto anoutside traffic road, public or private roadat least 1.80m above the ground, exceptfor condensation equipment, shall includea fixed deflector steering the exhaustedgases noticeably parallel to the wall.Exhaust holes and air intakes of sealedcircuit equipment opening at least 1.80mabove the ground shall be efficientlyprotected against any outside occurrencecapable of harming their normal operation.
RecommendationsD = 0.30m: Distance between centres of burnt gas
vent to the ground or roof overhang orabove a balcony.
E = 1.50m: Distance between centres of burnt gasvent to a wall at 90°, with windowventilation hole.
F = 0.80m: Distance between centres of burnt gasvent to a wall at 90°, with no opening.
G = 2.00m: Distance of burnt gas vent to a hedge ortrees
H = 0.10m: Distance between centres of burnt gasvent to a gutter or downpipe.
HDA
A
D
D
B
CB
G
E F
A B
n s h i n e , e v e n m o r e p r o g r e s sEDENA PROGRESS
13
Two 45° bends.
CONNECTIONS USING FLUE PACKAGE � FF 000002AND OPTIONS REAR OUTPUT (HORIZONTAL OUTLET)
REAR OUTPUT (horizontal outlet)
Rear direct outlet.Basic package � adjustable425 to 685 mm FF 000002.
Adjustable zoom outlet.
CONNECTIONS USING FLUE PACKAGE FF 000003
VERTICAL OUTPUT (vertical outlet)
Vertical flue adaptor canbe used with Ubbink orPoujoulat ducts.
8 m possible height.
Rear direct outlet� basic package+ � 1mextensionFP 119736.
3 m possible length, adjustable zoom outlet.
Raised outlet basic package �+ � 1mextensionFP 119736+ � 2 90° bendsFP 119830+ � terminalbend adaptorFP 000004.
1 90° bend = 1 m.3 m possible length, adjustable zoom outlet.
Offset rear outlet� basic package+ � 2 45°bends FP119832+ � 1m
extension FP 119736 + � terminal bendadaptor FP 000004.
2 45° bends = 1 m.3 m possible length, adjustable zoom outlet.
CONNECTIONS USING FLUE PACKAGE � FF 000001AND OPTIONS
LATERAL OR VERTICAL OUTPUT (horizontal outlet)
Rear direct outletBasic package �adjustable 710 to965 mm FF 000001.
Adjustable zoom outlet.
Basic package �lateral output usedfor raised output180° adjustable + � 90° bendFP 119830+ � terminal bendadaptor FP 000004.
1 90° bend = 1 m.3 m possible length, adjustable zoom outlet.
Basic package �extended lateraloutput + � 1mextensionFP 119736.
3 m possible length, adjustable zoom outlet.
Basic package� lateraloutput usedfor raisedoutput 180°adjustable + � 1mextension
FP 119736 + � 90° bend FP 119830+ � terminal bend adaptor FP 000004.
1 90° bend = 1 m.3 m possible length, adjustable zoom outlet.
1
1
2
132
3
41
1 6
26
41
5
53
4 5
5
52
5
53
4 2 5
PoujoulatouUbbink
FournitureCHAPPÉE
One 90° bend. Terminal bendadaptor.
400/600 mmadjustable rearoutput.
180° adjustable600/800 mm lateraloutput.
Vertical output.
CONNECTION FITTINGS
E D E N A P r o g r e s s : t h e b e s t s uEDENA PROGRESS
14
Models EDENA FF EDENA FFB EDENA LE EDENA LEB EDENA SE EDENA SEB24 28 32 24 28 32 16 24 28 32 24 28 32 18 24 28 32 24 28 32
Type of generator Heating Mixed Heating Mixed Heating MixedType of boiler Low TemperatureVenting Flue Flue Chimney Chimney Chimney ChimneyNominal power kW 24 28 32 24 28 32 16 24 29 32 24 29 32 20 24 28 32 24 28 32Heat output kW 26.14 30.70 35.56 26.14 30.70 35.56 17.9 26.7 31.8 35.5 26.7 31.8 35.5 21.5 25.9 30.8 34.8 25.9 30.8 34.8Smoke discharge kg/h - - - - - - 47.0 62.0 77.0 85.0 62.0 77.0 85.0 63.2 75.1 88.0 101.1 75.1 88.0 101.1Smoke volume l - - - - - - 3,712 5,537 6,595 7,363 2,237 6,595 7,363 4,459 5,372 6,388 7,218 5,372 6,388 7,218Required draught daPa - - - - - - 5 à 10 5 à 10 5 à 10 5 à 10 5 à 10 5 à 10 5 à 10 5 à 10 5 à 10 5 à 10 5 à 10 5 à 10 5 à 10 5 à 10100% and 70 C load output % 90.5 89.9 90.0 90.5 89.9 90.0 89.5 90.1 91.1 90.0 90.1 91.1 90.0 93.6 93.6 93.6 92.4 93.6 93.6 92.430% and 50 C load output % 90.7 89.7 90.2 90.7 89.7 90.0 90.0 90.2 92.3 90.2 90.2 92.3 90.2 90.3 92.0 91.4 92.1 92.0 91.4 92.1Losses when shut down t = 30 K W 62 62 74 116 116 128 121 149 176 188 203 230 242 87 110 125 140 164 176 194Auxiliary electric power 60 60 60 60 60 60 10 10 10 10 10 10 10 10 10 10 10 10 10 10Nominal water flow at NP = t = 15 K m3/h 1.37 1.60 1.83 1.37 1.60 1.83 0.91 1.37 1.66 1.83 1.37 1.66 1.83 1.14 1.37 1.60 1.83 1.37 1.60 1.83Boiler P at nominal flow mbar 6.8 7.0 7.6 10.0 2.0 3.2 6.1 6.8 7.0 7.6 6.8 7.0 7.6 6.4 6.8 7.0 7.6 6.8 7.0 7.6Water content l 15.4 15.4 18.8 15.4 18.8 18.8 15.4 15.4 18.8 18.8 15.4 18.8 18.8 15.4 15.4 18.8 18.8 15.4 18.8 18.8Max operating pressure (primary) bar 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4Test report reference n° 9770038 9 770 038/1 9770038 9 770 038/1 TD16143 TD16142 TD16211 TD16138 TD16142 TD16211 TD16138 16018 16018 16109 16010 16018 16109 16010Body CETIAT CTIF CTIFEC Reference 49AS 49AS 49AS 49AS 49AS 49AS 49BL 49BL 49BM 49BL 49BL 49BM 49BL 49AP 49AP 49BL 49AP 49AP 49BL 49AP
2257 2258 2259 2257 2258 2259 3272 3273 3561 3273 3273 3561 3273 0464 0465 3205 0466 0465 3205 0466Gas flow G.20 m3/h 2.81 3.22 3.69 2.81 3.22 3.69 1.89 2.82 3.60 3.75 2.82 3.60 3.75 2.27 2.75 3.26 3.69 2.75 3.26 3.69
G.25 m3/h 3.27 3.75 4.28 3.27 3.75 4.28 2.05 3.07 3.80 4.08 3.07 3.80 4.08 2.40 2.90 3.05 3.90 2.90 3.05 3.90Propane kg/h 2.066 2.369 2.704 2.066 2.369 2.704 - - - - - - - 1.712 2.014 2.398 2.706 2.014 2.398 2.706
* Performances obtained with 28 kW EDENA.
Specifications of boilers according to RT 2000
EDENA Progress SUPPLIEDLEB LE • Standard o Option AlternativeSEB SE
FFB FFGENERAL FEATURESMANDATORY – AT OPTION CONTROL MODULE
• • • • ECOCONTROL SP OBa/OBs• • • • ECOCONTROL SP 1a/1s• • • • ECOCONTROL SP 2a/2s• • • • ECOCONTROL SP 3a/3s• • • • ECOCONTROL SP 4a/4s
OPTIONSo o o o Pump, expansion tank, safety valve, pressure gaugeo o o o ECOCONTROL regulation
o Bend and extension adaptor for FFH modelo o Water tank below (HB) or cylindrical (CB)
o o o o Heating modules and safety module DOMESTIC HOT WATER ALTERNATIVESAB 120 litre white side by side water tankdelivered in one single packageinspection trap with checkable anodeadjustable feet fittedwater connection and loading pump
EDENA Progress SUPPLIEDLEB LE • Standard o Option AlternativeSEB SE
FFB FFGENERAL FEATURES
• Boiler delivered in 2 packages• Boiler delivered in 3 packages
• Boiler delivered fully assembled in one singlepackage with regulation as option
• Boiler delivered fully assembled in 2 packageswith regulation as option
• • • • Cast iron heating body insulated with 50 mmglass wool
• • • • White epoxy lacquered jacket• • Casing with double insulation: 30mm of ceramic
fibre and 50mm of glass woolFITTINGS
• • • • Control panel ready for control module fitting• • • Propane kit
• • • • 1 line burner with double valve gas valve• • • • Electronic ignition of burner and ionizing flame
control• • • • Drain cock• • • • Extractor fan
• • Accessories: cleaning brush, adjustable feet fitted• • One 120 litre DHW tank comprising:
- tank and enamelled steel exchanger with nochrome/injected insulation
- white epoxy lacquered jacket- inspection trap at front with checkable anode- adjustable feet fitted- water connection and loading pump
• • 1 flue package at option
n s h i n e , e v e n m o r e p r o g r e s sEDENA PROGRESS
15
1/2" Ø malegas inlet
1/2" Ødrain cock
3/4" Ø male recycling
3/4" Ø malecold water outlet
1" Ø male heating return
1" Ø male heating output
Ø Flue
580 853
3/4" Ø malecold water inlet
1,460
1/2" Ø malegas inlet
3/4" Ø male recycling
3/4" Ø malecold water outlet
1" Ø male heating output
1" Ø male heating return
3/4" Ø malecold water
inlet
853
EDENA Progress FFB/LEB/SEB
Gas inlet
1/2" Ødrain cock
1" Ø male heating return
1" Ø male heating output
Ø Flue
A
850
580A
1/2" Ø malegas inlet
1" Ø male heating return
1" Ø male heating output
Ø Flue
EDENA Progress FF/LE/SE
Drain cock
Ø Flue
1/2" Ø malegas inlet
1" Ø male heating return
1" Ø male heating output
1,160A
8563/4" Ø male recycling
3/4" Ø male cold water inlet
3/4" Ø malecold water outlet
1,160A
856
1/2" Ø malegas inlet
3/4" Ø male recycling
3/4" Ø male cold water inlet
3/4" Ø malecold water outlet
1" Ø male heating return
1" Ø male heating output
EDENA Progress FFA/LEA/SEA with side by side PIM
EDENA Progress 1101 FFB 1111 LEB 1101 SEBModel 24 28 32 24 28 32 24 28 32Ø D FFH mm 100 100 100 - - - - - -
FFV mm 125 125 125 - - - - - -Ø D mm - - - 125 139 153 125 139 153Weight kg 249 249 268 245 264 264 245 264 264
EDENA Progress 1101 FFA 1111 1101 1111 LEAwith PIM AB LEA SEA 1101 SEAModel 24 28 32 16 18 24 28 32Capacity l 120 120 120 120 120 120 120 126Dimension A mm 853 853 853 853 853 853 853 853Ø D FH mm 100 100 100 - - - - -
FV mm 125 125 125 - - - - -Ø D mm - - - 111 125 125 139 153Weight kg 244 244 263 221 244 244 256 268
EDENA Progress 1101 FF 1111 LE 1101 SEModel 24 28 32 16 24 28 32 18 24 28 32Dimension A mm 660 660 660 760 760 760 760 660 660 660 660Ø D FFH mm 100 100 100 - - - - - - - -
FFV mm 125 125 125 - - - - - - - -Ø D mm - - - 111 125 139 153 125 125 139 153Weight kg 129 129 148 106 129 148 148 129 129 148 148
Gro
up
e M
ult
imed
ia P
rescri
pte
lR
CPa
ris B
425
058
211
- R
éf. C
H E
X 5
857
-5-0
1-20
03 -
This
doc
umen
t is
not
lega
lly b
indi
ng a
nd is
not
of
a co
ntra
ctua
l nat
ure.
Tec
hnic
al s
peci
ficat
ions
are
pro
vide
d fo
r re
fere
nce
purp
oses
onl
y.
The best sunshine, even more progress