15.75 in
DESCRIPTION
quick check of fields in a test structure – design will be improved. water jetted plate. A Ross Engineering Toroid. 20 kV bias. 15.75 in. ~5.6 cm. ground plane. shaped button cable connection electrode. read C/cm as kV/cm. Tipped toroid connection. - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: 15.75 in](https://reader035.vdocuments.mx/reader035/viewer/2022062814/568167d3550346895ddd26f6/html5/thumbnails/1.jpg)
15.75 in
quick check of fields in a test structure – design will be improved
A Ross Engineering Toroidwater jetted plate
ground planeshaped button cable connection electrode
20 kV bias
~5.6 cm
![Page 2: 15.75 in](https://reader035.vdocuments.mx/reader035/viewer/2022062814/568167d3550346895ddd26f6/html5/thumbnails/2.jpg)
read C/cm as kV/cm
![Page 3: 15.75 in](https://reader035.vdocuments.mx/reader035/viewer/2022062814/568167d3550346895ddd26f6/html5/thumbnails/3.jpg)
![Page 4: 15.75 in](https://reader035.vdocuments.mx/reader035/viewer/2022062814/568167d3550346895ddd26f6/html5/thumbnails/4.jpg)
![Page 5: 15.75 in](https://reader035.vdocuments.mx/reader035/viewer/2022062814/568167d3550346895ddd26f6/html5/thumbnails/5.jpg)
Tipped toroid connection
top of 3/8 in plate ¾ in below toroid center
plate to floor 5.3 cm
![Page 6: 15.75 in](https://reader035.vdocuments.mx/reader035/viewer/2022062814/568167d3550346895ddd26f6/html5/thumbnails/6.jpg)
tipped toroid connection
![Page 7: 15.75 in](https://reader035.vdocuments.mx/reader035/viewer/2022062814/568167d3550346895ddd26f6/html5/thumbnails/7.jpg)
can raise toroid to equalize field on disk with plate corner
![Page 8: 15.75 in](https://reader035.vdocuments.mx/reader035/viewer/2022062814/568167d3550346895ddd26f6/html5/thumbnails/8.jpg)
6 in radius sphere section
3/8 inch high
1/8 inch hole fillet radius .02 inch
![Page 9: 15.75 in](https://reader035.vdocuments.mx/reader035/viewer/2022062814/568167d3550346895ddd26f6/html5/thumbnails/9.jpg)
![Page 10: 15.75 in](https://reader035.vdocuments.mx/reader035/viewer/2022062814/568167d3550346895ddd26f6/html5/thumbnails/10.jpg)
Hot spot is on disk edge for this case with top 7/8 inch below toroid center
![Page 11: 15.75 in](https://reader035.vdocuments.mx/reader035/viewer/2022062814/568167d3550346895ddd26f6/html5/thumbnails/11.jpg)
![Page 12: 15.75 in](https://reader035.vdocuments.mx/reader035/viewer/2022062814/568167d3550346895ddd26f6/html5/thumbnails/12.jpg)
Ross Engineering T201 toroid
21 inch outside diameter3 inch diameter ring
![Page 13: 15.75 in](https://reader035.vdocuments.mx/reader035/viewer/2022062814/568167d3550346895ddd26f6/html5/thumbnails/13.jpg)
The T201 is rated for 200 kV
This is a check of this design to see what field they are running with a 200 kV rating.
Calculate the field with toroid far from ground boundaries with a 200 kV bias
The potential is shown here.
![Page 14: 15.75 in](https://reader035.vdocuments.mx/reader035/viewer/2022062814/568167d3550346895ddd26f6/html5/thumbnails/14.jpg)
The field strength is shown here.
The maximum field on the surface of the toroid is 20 kV/cm with a 200 kV bias. This is 2/3 of the breakdown field in air.
Ross Engineering T201 toroid biased to 200 kV