1508-1t1412 - midea · 1508-1t1412 commercial air ... 2014 launched the all dc inverter v5x...

25
COMMERCIAL AIR CONDITIONERS Precision AC / Base Station AC Precision AC / Base Station AC ss Units ditioner Department, Industry Avenue, hina without notice for further improvement

Upload: hoangdan

Post on 17-Apr-2018

228 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: 1508-1T1412 - Midea · 1508-1T1412 COMMERCIAL AIR ... 2014 Launched the All DC Inverter V5X globally ... Midea can supply this kind of precision air conditioner, the Micool and MDP

1508-1T1412

COMMERCIAL AIR CONDITIONERS

Precision AC / Base Station ACP

recision AC

/ Base S

tation AC

D e a l e r i n f o r m a t i o n

Commercial Air Conditioner Business Units

Midea Group

Add: West Region of Midea Commercial Air Conditioner Department, Industry Avenue,

Beijiao, Shunde, Foshan, Guangdong, P. R. China

Postal code: 528311

Tel: +86-757-26338346 Fax: +86-757-22390205

http://global.midea.com.cn

http://www.midea.com

Note: The data in this book may be changed without notice for further improvement

on quality and performance.

Ver.2014.12

Page 2: 1508-1T1412 - Midea · 1508-1T1412 COMMERCIAL AIR ... 2014 Launched the All DC Inverter V5X globally ... Midea can supply this kind of precision air conditioner, the Micool and MDP

Midea CAC (MCAC)As a key subsidiary of Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial solutions. Since 1999 MCAC has contributed to the R&D and innovation of technologically-based commercial solutions. Cooperation with leading global enterprises coupled with independent R&D has enabled MCAC to implement thousands of commercial air-conditioning projects worldwide.

At present, MCAC is one of the globally leading product suppliers, underpinned by a mature marketing, sales, and project design framework.

There are three production bases in Shunde, Chongqing and Hefei.MCAC Shunde: 38 product lines focusing on VRF (DC inverters and digital scroll products), split products, heat pump water heaters, and AHU/FCU.MCAC Chongqing: 14 product lines focusing on water cooled centrifugal/screw/scroll chillers, air cooled screw/scroll chillers, and AHU/FCU.MCAC Hefei: 11 product lines focusing on VRF, chillers, and heat pump water heaters.

Year

2000

2004

20062001 2013

2007

20101999

2011 2014

2014 Launched the All DC Inverter V5X globally2013 Launched the super high efficiency centrifugal chiller with full falling film technology2011 Launched the DC Inverter V4 Plus globally2010 Built the 3rd manufacturing base in Hefei2007 Won the first Midea centrifugal chiller project oversea2006 Launched the first VSD centrifugal chiller 2004 Acquired MGRE entered the chiller industry2001 Partnered with Copeland to develop the digital scroll VRF system2000 Developed the first inverter VRF With Toshiba1999 Entered the CAC field

Page 3: 1508-1T1412 - Midea · 1508-1T1412 COMMERCIAL AIR ... 2014 Launched the All DC Inverter V5X globally ... Midea can supply this kind of precision air conditioner, the Micool and MDP

Midea CAC (MCAC)As a key subsidiary of Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial solutions. Since 1999 MCAC has contributed to the R&D and innovation of technologically-based commercial solutions. Cooperation with leading global enterprises coupled with independent R&D has enabled MCAC to implement thousands of commercial air-conditioning projects worldwide.

At present, MCAC is one of the globally leading product suppliers, underpinned by a mature marketing, sales, and project design framework.

There are three production bases in Shunde, Chongqing and Hefei.MCAC Shunde: 38 product lines focusing on VRF (DC inverters and digital scroll products), split products, heat pump water heaters, and AHU/FCU.MCAC Chongqing: 14 product lines focusing on water cooled centrifugal/screw/scroll chillers, air cooled screw/scroll chillers, and AHU/FCU.MCAC Hefei: 11 product lines focusing on VRF, chillers, and heat pump water heaters.

Year

2000

2004

20062001 2013

2007

20101999

2011 2014

2014 Launched the All DC Inverter V5X globally2013 Launched the super high efficiency centrifugal chiller with full falling film technology2011 Launched the DC Inverter V4 Plus globally2010 Built the 3rd manufacturing base in Hefei2007 Won the first Midea centrifugal chiller project oversea2006 Launched the first VSD centrifugal chiller 2004 Acquired MGRE entered the chiller industry2001 Partnered with Copeland to develop the digital scroll VRF system2000 Developed the first inverter VRF With Toshiba1999 Entered the CAC field

Page 4: 1508-1T1412 - Midea · 1508-1T1412 COMMERCIAL AIR ... 2014 Launched the All DC Inverter V5X globally ... Midea can supply this kind of precision air conditioner, the Micool and MDP

Contents04

05

07

17

22

04

Product lineups

Nomenclature

Precision AC

Base station AC

Project references

Product lineups

Project references

Nom

enclatureP

roduct lineupsP

recision AC

Base station A

C

Project references

Nom

enclatureP

roduct lineupsP

recision AC

Base station A

C

PrecisionAC

Base staticonAC

MDP series(R22, R410A)

Micool DXair cool series(R22, R410A)

Compact type(R22,R407c customized)

Split type(R22, R410A customized)

With free cooling

Without free cooling

Front delivery (Up)Front intake (Down)

Top deliveryFront intake

Universaloutdoor unit

5.5kW 7.5kW 12.5kW

20.2~30.9kW 35kW

35kW

40.3~58.9kW 71.1~90.1kW

20.2~30.9kW 40.3~58.9kW 71.1~90.1kW

Underfloor deliveryTop intake

6.0kW,7.5kW 12.0kW

5.5kW 13.0kW

5.5kW 7.59kW

7.59kW

13.0kW

Page 5: 1508-1T1412 - Midea · 1508-1T1412 COMMERCIAL AIR ... 2014 Launched the All DC Inverter V5X globally ... Midea can supply this kind of precision air conditioner, the Micool and MDP

Contents04

05

07

17

22

04

Product lineups

Nomenclature

Precision AC

Base station AC

Project references

Product lineups

Project references

Nom

enclatureP

roduct lineupsP

recision AC

Base station A

C

Project references

Nom

enclatureP

roduct lineupsP

recision AC

Base station A

C

PrecisionAC

Base staticonAC

MDP series(R22, R410A)

Micool DXair cool series(R22, R410A)

Compact type(R22,R407c customized)

Split type(R22, R410A customized)

With free cooling

Without free cooling

Front delivery (Up)Front intake (Down)

Top deliveryFront intake

Universaloutdoor unit

5.5kW 7.5kW 12.5kW

20.2~30.9kW 35kW

35kW

40.3~58.9kW 71.1~90.1kW

20.2~30.9kW 40.3~58.9kW 71.1~90.1kW

Underfloor deliveryTop intake

6.0kW,7.5kW 12.0kW

5.5kW 13.0kW

5.5kW 7.59kW

7.59kW

13.0kW

Page 6: 1508-1T1412 - Midea · 1508-1T1412 COMMERCIAL AIR ... 2014 Launched the All DC Inverter V5X globally ... Midea can supply this kind of precision air conditioner, the Micool and MDP

NomenclaturePrecision AC

Air Cool Series

Midea

Power SupplyT: 380V~ 3Ph 50HzS: 220V~ 1Ph 50Hz

Compressor Quantity

Nominal Cooling Capacity (20kW)

Indoor Unit TypeU: Top delivery & front intakeD: Underfloor delivery & top intakeV: Front delivery & front intake

Series Number

Humidification FunctionS: With humidification function0: Without humidification function

Electric Heater Function1: With electric heater0: Without electric heater

Refrigerant TypeN: R410AR: R22

M A T 1 1 1020U N

Indoor unit:

Base Station AC

Nominal Cooling Capacity (6kW)

Series Number

Cooling with Electric Heater Type

Compact Type

Base Station AC

Power SupplyS: 380V~ 3Ph 50Hz

KC JZ60D S (E1)

Compact type:

Midea

Fan Quantity

Nominal Heat-exchange Capacity (33kW)

Refrigerant TypeN: R410AOmit: R22

1 N033MA

Outdoor unit:

Power SupplySC: 380V~ 3Ph 50HzCX: 220V~ 1Ph 50Hz

Floor Standing Type

Function Type1(R2): Without free cooling function2(R2): With free cooling function

55 JZCXL

Split Type - Indoor unit:

Nominal Cooling Capacity (5.5kW)

Split Type

Base Station AC

KF 1(R2)

Power SupplyC: 220V~ 1Ph 50Hz

Outdoor Unit

Series Number

55 210CW

Split Type - Outdoor unit:

Nominal Cooling Capacity (5.5kW)

Split Type

KF

05 06

Nom

enclature

Nom

enclature

S

Page 7: 1508-1T1412 - Midea · 1508-1T1412 COMMERCIAL AIR ... 2014 Launched the All DC Inverter V5X globally ... Midea can supply this kind of precision air conditioner, the Micool and MDP

NomenclaturePrecision AC

Air Cool Series

Midea

Power SupplyT: 380V~ 3Ph 50HzS: 220V~ 1Ph 50Hz

Compressor Quantity

Nominal Cooling Capacity (20kW)

Indoor Unit TypeU: Top delivery & front intakeD: Underfloor delivery & top intakeV: Front delivery & front intake

Series Number

Humidification FunctionS: With humidification function0: Without humidification function

Electric Heater Function1: With electric heater0: Without electric heater

Refrigerant TypeN: R410AR: R22

M A T 1 1 1020U N

Indoor unit:

Base Station AC

Nominal Cooling Capacity (6kW)

Series Number

Cooling with Electric Heater Type

Compact Type

Base Station AC

Power SupplyS: 380V~ 3Ph 50Hz

KC JZ60D S (E1)

Compact type:

Midea

Fan Quantity

Nominal Heat-exchange Capacity (33kW)

Refrigerant TypeN: R410AOmit: R22

1 N033MA

Outdoor unit:

Power SupplySC: 380V~ 3Ph 50HzCX: 220V~ 1Ph 50Hz

Floor Standing Type

Function Type1(R2): Without free cooling function2(R2): With free cooling function

55 JZCXL

Split Type - Indoor unit:

Nominal Cooling Capacity (5.5kW)

Split Type

Base Station AC

KF 1(R2)

Power SupplyC: 220V~ 1Ph 50Hz

Outdoor Unit

Series Number

55 210CW

Split Type - Outdoor unit:

Nominal Cooling Capacity (5.5kW)

Split Type

KF

05 06

Nom

enclature

Nom

enclature

S

Page 8: 1508-1T1412 - Midea · 1508-1T1412 COMMERCIAL AIR ... 2014 Launched the All DC Inverter V5X globally ... Midea can supply this kind of precision air conditioner, the Micool and MDP

07 08

FeaturesIDC rooms solutions

Higher reliable scroll compressor

High efficient evaporator, energy-saving dehumidify

Immersed electrode humidifier

Computer equipment in IDC rooms generates heat, and is sensitive to heat, humidity, and dust, but also the need for every high resilience and failover requirements. Maintaining a stable temperature and humidity within tight tolerances is critical to IT system reliability.Midea can supply this kind of precision air conditioner, the Micool and MDP series. They can control temperature, humidity and particle filtration within tight tolerances 24 hours a day and can be remotely monitored.

Famous brand, Copeland, high efficient scroll compressor.Built-in thermal multi-protectors that prevent motor overheating.Better liquid handing. Axial and radial compliance in compressor allow the scroll members to separate in the presence of liquid refrigerant to provide protection against liquid-refrigerant damage.No complex internal suction and discharge valves for quieter operation and higher reliability.Notes: Scroll comprossor is only available for Micool air cool series A/C.

High reliability, well-known brand, Carel.Adopt advantage control technology of immersed electrode humidifier. it can make the air conditioner more accuratedly control the relative humidity through the smart logic programs.Automatically self-cleaning, reduce the maintenance frequency of cylinder. Openable cylinder, quick click-on closing, with a reabber gasket to ensure perfect water- tightness between the two parts of cylinder.

Adopt V-shape evaporator, enlarge the heat exchanger surface.Inner grooved copper pipe, enhance the heat exchange ability.Change the valid evaporator’ s section by built-in electromagnetic valve to dehumidification without apparent temperature fluctuation.Inner grooved copper pipe

Traditional finAdvanced fin

0ºC 5ºC 20ºC

[60s`]

Special compressor

Normal compressor

Ambient temperature

Extend operating range

Improved 50% Improved 20%

Compressor efficiency

Precision AC

Precision A

C

Page 9: 1508-1T1412 - Midea · 1508-1T1412 COMMERCIAL AIR ... 2014 Launched the All DC Inverter V5X globally ... Midea can supply this kind of precision air conditioner, the Micool and MDP

07 08

FeaturesIDC rooms solutions

Higher reliable scroll compressor

High efficient evaporator, energy-saving dehumidify

Immersed electrode humidifier

Computer equipment in IDC rooms generates heat, and is sensitive to heat, humidity, and dust, but also the need for every high resilience and failover requirements. Maintaining a stable temperature and humidity within tight tolerances is critical to IT system reliability.Midea can supply this kind of precision air conditioner, the Micool and MDP series. They can control temperature, humidity and particle filtration within tight tolerances 24 hours a day and can be remotely monitored.

Famous brand, Copeland, high efficient scroll compressor.Built-in thermal multi-protectors that prevent motor overheating.Better liquid handing. Axial and radial compliance in compressor allow the scroll members to separate in the presence of liquid refrigerant to provide protection against liquid-refrigerant damage.No complex internal suction and discharge valves for quieter operation and higher reliability.Notes: Scroll comprossor is only available for Micool air cool series A/C.

High reliability, well-known brand, Carel.Adopt advantage control technology of immersed electrode humidifier. it can make the air conditioner more accuratedly control the relative humidity through the smart logic programs.Automatically self-cleaning, reduce the maintenance frequency of cylinder. Openable cylinder, quick click-on closing, with a reabber gasket to ensure perfect water- tightness between the two parts of cylinder.

Adopt V-shape evaporator, enlarge the heat exchanger surface.Inner grooved copper pipe, enhance the heat exchange ability.Change the valid evaporator’ s section by built-in electromagnetic valve to dehumidification without apparent temperature fluctuation.Inner grooved copper pipe

Traditional finAdvanced fin

0ºC 5ºC 20ºC

[60s`]

Special compressor

Normal compressor

Ambient temperature

Extend operating range

Improved 50% Improved 20%

Compressor efficiency

Precision AC

Precision A

C

Page 10: 1508-1T1412 - Midea · 1508-1T1412 COMMERCIAL AIR ... 2014 Launched the All DC Inverter V5X globally ... Midea can supply this kind of precision air conditioner, the Micool and MDP

09 10

High efficient indoor & outdoor motors

Accurate microprocessor control technology

Outdoor motor: Well-known brand, Ziehl-Abegg.According to different operating parameter, fan motor speeds can be automatically adjusted by frequency converter in electric box.Metal impeller, anti-corrosion design, made of die-cast aluminium.

Indoor motor:Standard - High efficient motor and FC fan. Fan speed can be adjusted through chaning different belt roller. Optional - EC fan motor, more efficient. It can automatically adjust running speed to ensure supply required air volume at different static pressure.

Indoor EC fan motor(Optional)

Indoor FC fan(Standard)

Double wall casing design, improve heat insulation

Heat-insulated casing can prevent the condensate from the unit body.Galvanized steel sheet of nitrogen treatment and powder spray coating make the casing of indoor unit anti-rust and fire resistance.

Empty

External

Internal

Reduce exchanged

heat.

Galvanized steel sheet

Powder spray coating

The valve is connected with the pipe of evaporator. When reducing the humidity, the valve will be switch off, and a part of evaporator will not be available. It will be fast to get rid of the water in air.

High sensitivity sensor can accurately detect the temperature and humidity of the condition and send the signal to the main control module.

Temperature & humidity sensor

One way electric valve Carel, high quality, humidity control module. It can receive and analyse the signal from humidity sensor and control the steam cylinder to make the relative humidity meet the requirement.

Humidity control module

Frequency converter is fixed in outdoor unit and connected with outdoor fan motor. It adopt vector control technology. The main control module of air conditioner according to the signal from all sensor, transform signal to frequency converter to adjust the outdoor fan motor speed.

Frequency converter

High quality sensor can accurately detect the pressure of the refrigerant system, and send the signal to the main control module.

Pressure sensor

High and low pressure protection.Discharge temperature protection.Lack of phase protection.Phase sequence protection.Water leakage protection.

Multiple protections

Easy maintenanceOnly open the door to all repair and maintain the units.Key components ( compressor, fan-motor, filter, main PCB board, etc. ) is designed to put in the front of indoor units.Rotalock type connection between compressor and pipes. when change the compressor, it is no need to welding.

Outdoor fan motor & Frequency converter

Multiple function control system The running parameter can be display in the screen of control panel when the air conditioner is in operating status.At least 100 pieces of error-records will be stored in the control system.Networking solution of Max. 8 units can be achieved.Rotary function, standby function, casecade function and conflict-management can be ensure the units keep operating in the whole year.Background monitoring system can be built. (Customized)

Rotary function

Start operation

Main unit Stops

Main Slave Slave Main

Runs Runs

Slave unit Stops Stops Runs

Casecade function

Start operation Slave unit runs.

Heat loadincreases.

Heat loadis normal.

Slave unit stops.

Main unit Runs

Slave unit Stops Stops Runs

Standby function

Start operation

Error on main unit.

Main unit Stops

Main Slave

Runs

Slave unit Stops Runs

Precision A

C

Precision A

C

Air plenum box as optional (Only for top delivery models)

Air filter as standard

Air plenum box as optional can change the direction of air flow. Air plenum bos with grill can ensure the evenness of air supply flow from the products.The grills in air plenum box can be adjusted by hand. It is very easy to set the direction of air supply flow.

Air filter, grade G2, is the standard for MDP series products.Air filter, grade G4, is the standard for Micool DX air cool series products.When the filter is too dirty, the unit will send the promoting message for cleaning the filter.

Page 11: 1508-1T1412 - Midea · 1508-1T1412 COMMERCIAL AIR ... 2014 Launched the All DC Inverter V5X globally ... Midea can supply this kind of precision air conditioner, the Micool and MDP

09 10

High efficient indoor & outdoor motors

Accurate microprocessor control technology

Outdoor motor: Well-known brand, Ziehl-Abegg.According to different operating parameter, fan motor speeds can be automatically adjusted by frequency converter in electric box.Metal impeller, anti-corrosion design, made of die-cast aluminium.

Indoor motor:Standard - High efficient motor and FC fan. Fan speed can be adjusted through chaning different belt roller. Optional - EC fan motor, more efficient. It can automatically adjust running speed to ensure supply required air volume at different static pressure.

Indoor EC fan motor(Optional)

Indoor FC fan(Standard)

Double wall casing design, improve heat insulation

Heat-insulated casing can prevent the condensate from the unit body.Galvanized steel sheet of nitrogen treatment and powder spray coating make the casing of indoor unit anti-rust and fire resistance.

Empty

External

Internal

Reduce exchanged

heat.

Galvanized steel sheet

Powder spray coating

The valve is connected with the pipe of evaporator. When reducing the humidity, the valve will be switch off, and a part of evaporator will not be available. It will be fast to get rid of the water in air.

High sensitivity sensor can accurately detect the temperature and humidity of the condition and send the signal to the main control module.

Temperature & humidity sensor

One way electric valve Carel, high quality, humidity control module. It can receive and analyse the signal from humidity sensor and control the steam cylinder to make the relative humidity meet the requirement.

Humidity control module

Frequency converter is fixed in outdoor unit and connected with outdoor fan motor. It adopt vector control technology. The main control module of air conditioner according to the signal from all sensor, transform signal to frequency converter to adjust the outdoor fan motor speed.

Frequency converter

High quality sensor can accurately detect the pressure of the refrigerant system, and send the signal to the main control module.

Pressure sensor

High and low pressure protection.Discharge temperature protection.Lack of phase protection.Phase sequence protection.Water leakage protection.

Multiple protections

Easy maintenanceOnly open the door to all repair and maintain the units.Key components ( compressor, fan-motor, filter, main PCB board, etc. ) is designed to put in the front of indoor units.Rotalock type connection between compressor and pipes. when change the compressor, it is no need to welding.

Outdoor fan motor & Frequency converter

Multiple function control system The running parameter can be display in the screen of control panel when the air conditioner is in operating status.At least 100 pieces of error-records will be stored in the control system.Networking solution of Max. 8 units can be achieved.Rotary function, standby function, casecade function and conflict-management can be ensure the units keep operating in the whole year.Background monitoring system can be built. (Customized)

Rotary function

Start operation

Main unit Stops

Main Slave Slave Main

Runs Runs

Slave unit Stops Stops Runs

Casecade function

Start operation Slave unit runs.

Heat loadincreases.

Heat loadis normal.

Slave unit stops.

Main unit Runs

Slave unit Stops Stops Runs

Standby function

Start operation

Error on main unit.

Main unit Stops

Main Slave

Runs

Slave unit Stops Runs

Precision A

C

Precision A

C

Air plenum box as optional (Only for top delivery models)

Air filter as standard

Air plenum box as optional can change the direction of air flow. Air plenum bos with grill can ensure the evenness of air supply flow from the products.The grills in air plenum box can be adjusted by hand. It is very easy to set the direction of air supply flow.

Air filter, grade G2, is the standard for MDP series products.Air filter, grade G4, is the standard for Micool DX air cool series products.When the filter is too dirty, the unit will send the promoting message for cleaning the filter.

Page 12: 1508-1T1412 - Midea · 1508-1T1412 COMMERCIAL AIR ... 2014 Launched the All DC Inverter V5X globally ... Midea can supply this kind of precision air conditioner, the Micool and MDP

1211

Precision AC - Micool DX air cool seriesR410AR410A R22R22

Outdoor ambient temperature range:

-20°C~45°C ( -34°C~45°C, Customized)Indoor ambient temperature range:

0°C~45°C

Notes: All the air plenum boxes are assembled on site.

Dimension (Air plenum box)

MF4010HM

MF6010HM

MF4015HM

MF6015HM

MF4020HM

MF6020HM

MF4030HM

MF6030HM

895mm 870mm 400mm 711.8mm 345.6mm 1

1

2

2

2

2

3

3

545.6mm

545.6mm

545.6mm

545.6mm

345.6mm

345.6mm

345.6mm

711.8mm

516.8mm

516.8mm

711.8mm

711.8mm

711.8mm

711.8mm

400mm

400mm

400mm

600mm

600mm

600mm

600mm

975mm

1,270mm

1,865mm

2,810mm

2,810mm

1,865mm

1,480mm

975mm

920mm

920mm

930mm

920mm

920mm

930mm

920mm

920mm

175mm

175mm

145mm

195mm

250mm

230mm

205mm

310mm 32.5kg 48.5kg

38.0kg 50.0kg

46.0kg 60.0kg

49.0kg 59.0kg

58.0kg 72.0kg

65.0kg 84.0kg

79.0kg 104.0kg

32.5kg24.5kg

870mm

870mm

870mm

870mm

870mm

870mm

870mm

895mm

1,400mm

1,400mm

1,790mm

1,790mm

2,685mm

2,685mm

ModelLength

Dimension (Assembled) Outlet grille

LengthWidth Width QuantityHeight Length

Packing

Width Height

Weight

Net Gross

20.2kW~30.9kW 34.0kW 40.3kW~59.1kW 71.1kW~90.1kW

Top delivery

Front intake

34.0kW 40.3kW~59.1kW 71.1kW~90.1kW20.2kW~30.9kW

Underfloor delivery

Top intake

Air plenum box

(Optional)

Specifications are subject to change without prior notice for product improvement.

[2] (In specification): Vertical installation of outdoor unit.

[1] (In specification): Horizontal installation of outdoor unit.

Cooling 24 17 35

Entering air DB (°C) Entering air DB (°C)Entering air WB (°C)

Indoor side Outdoor side

Nominal test condition (Temperature)

Universal

outdoor unit

MDP series

Specifications (R410A)

Specifications (R22)Indoor unit MAV006S1R2S

MA0071 MA0101 MA0101 MA0162

MAV008S1R2S MAV008T1R2S MAV013T1R2S

Outdoor unit

Power supply (Indoor unit) 220V~, 1Ph, 50Hz 220V~, 1Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-

Power supply (Outdoor unit) 220V~, 1Ph, 50Hz 220V~, 1Ph, 50Hz 220V~, 1Ph, 50Hz 220V~, 1Ph, 50Hz-

Ф16.5

105/117

30/33 40/43 40/43 65/76

107/119 107/119 140/151

956×770×420

842×695×324 945×810×395 945×810×395 904×1,332×414

1,050×900×490 1,050×900×490 1,030×1,456×435

Ф16.5 Ф16.5 Ф16.5mm

mm

mm

kg

kg

Drainage pipe (OD)

Packing (W×H×D)

810×2,030×530 810×2,030×530 810×2,030×530 880×2,030×620mmPacking (W×H×D)

700×1,880×425 700×1,880×425 700×1,880×425 760×1,880×515mmDimension (W×H×D)

Dimension (W×H×D)

Indoor unit

Outdoor unit

Net/gross weight

Weight

5.5

4.95

1,550

3.5

2.5

5.6

27

Ф6/Ф12.7 Ф6/Ф16 Ф6/Ф16 Ф9.52/Ф19

32 18 23

6.7 6.7 9.4

2.5 2.5 2.5

3.5 3.5 4.0

2,050 2,050 2,950

3.003.003.003.00

7.5

6.75 6.75 11.25

7.5 12.5

Cooling

Total capacity kW

kW

kW

kW

A

mm

W/W

kg/h

Sensible capacity

EER

Air volume

Rated input

Humidification capacity

Rated current

Size (Liquid/gas)Rfrigerant pipe

Elect. heater input

m3/h

Notes:1. The nominal cooling capacity is based on the following conditons: Indoor temperature: 24°CDB, 17°CWB; Outdoor temperature: 35°CDB.2. If the refrigerant pipe length is less than 40m and more than 20m, the long-pipe accessories is necessary.3. Specifications are subject to change without prior notice for product improvement.

Front delivery, front intake 5.5kW, 7.5kW 12.5kW, 17kW

R410AR410A R22R22

Outdoor ambient temperature range:

-15°C~48°C

Indoor ambient temperature range:

0°C~40°C

Indoor unit MAV006S1N2S

MA0071N MA0101N MA0162N MA0212N

MAV008T1N2S MAV013T1N2S MAV018T1N2S

Outdoor unit

Power supply (Indoor unit) 220V~, 1Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-

Power supply (Outdoor unit) 220V~, 1Ph, 50Hz 220V~, 1Ph, 50Hz 220V~, 1Ph, 50Hz 220V~, 1Ph, 50Hz-

Ф16.5

105/117

30/33 40/43 65/76 89/106

107/119 140/151 190/208

956×770×420

842×695×324 945×810×395 904×1,332×414 1,120×1,558×528

1,050×900×490 1,030×1,456×435 1,270×1,720×565

Ф16.5 Ф16.5 Ф16.5mm

mm

mm

kg

kg

Drainage pipe (OD)

Packing (W×H×D)

810×2,030×530 810×2,030×530 880×2,030×620 920×2,030×775mmPacking (W×H×D)

700×1,880×425 700×1,880×425 760×1,880×515 800×1,880×670mmDimension (W×H×D)

Dimension (W×H×D)

Indoor unit

Outdoor unit

Net/gross weight

Weight

5.5

4.95

1,550

3.5

2.5

5.6

27

Ф6/Ф12.7 Ф6/Ф16 Ф9.52/Ф19 Ф9.52/Ф19

18 23 26

6.7 9.4 11.2

2.5 2.5 2.5

3.5 4.0 4.0

2,050 2,950 4,500

2.903.002.902.91

7.45

6.75 11.25 15.3

12.5 17.0

Cooling

Total capacity kW

kW

kW

kW

A

mm

W/W

kg/h

Sensible capacity

EER

Air volume

Rated input

Humidification capacity

Rated current

Size (Liquid/gas)Rfrigerant pipe

Elect. heater input

m3/h

Precision A

C

Precision A

C

Page 13: 1508-1T1412 - Midea · 1508-1T1412 COMMERCIAL AIR ... 2014 Launched the All DC Inverter V5X globally ... Midea can supply this kind of precision air conditioner, the Micool and MDP

1211

Precision AC - Micool DX air cool seriesR410AR410A R22R22

Outdoor ambient temperature range:

-20°C~45°C ( -34°C~45°C, Customized)Indoor ambient temperature range:

0°C~45°C

Notes: All the air plenum boxes are assembled on site.

Dimension (Air plenum box)

MF4010HM

MF6010HM

MF4015HM

MF6015HM

MF4020HM

MF6020HM

MF4030HM

MF6030HM

895mm 870mm 400mm 711.8mm 345.6mm 1

1

2

2

2

2

3

3

545.6mm

545.6mm

545.6mm

545.6mm

345.6mm

345.6mm

345.6mm

711.8mm

516.8mm

516.8mm

711.8mm

711.8mm

711.8mm

711.8mm

400mm

400mm

400mm

600mm

600mm

600mm

600mm

975mm

1,270mm

1,865mm

2,810mm

2,810mm

1,865mm

1,480mm

975mm

920mm

920mm

930mm

920mm

920mm

930mm

920mm

920mm

175mm

175mm

145mm

195mm

250mm

230mm

205mm

310mm 32.5kg 48.5kg

38.0kg 50.0kg

46.0kg 60.0kg

49.0kg 59.0kg

58.0kg 72.0kg

65.0kg 84.0kg

79.0kg 104.0kg

32.5kg24.5kg

870mm

870mm

870mm

870mm

870mm

870mm

870mm

895mm

1,400mm

1,400mm

1,790mm

1,790mm

2,685mm

2,685mm

ModelLength

Dimension (Assembled) Outlet grille

LengthWidth Width QuantityHeight Length

Packing

Width Height

Weight

Net Gross

20.2kW~30.9kW 34.0kW 40.3kW~59.1kW 71.1kW~90.1kW

Top delivery

Front intake

34.0kW 40.3kW~59.1kW 71.1kW~90.1kW20.2kW~30.9kW

Underfloor delivery

Top intake

Air plenum box

(Optional)

Specifications are subject to change without prior notice for product improvement.

[2] (In specification): Vertical installation of outdoor unit.

[1] (In specification): Horizontal installation of outdoor unit.

Cooling 24 17 35

Entering air DB (°C) Entering air DB (°C)Entering air WB (°C)

Indoor side Outdoor side

Nominal test condition (Temperature)

Universal

outdoor unit

MDP series

Specifications (R410A)

Specifications (R22)Indoor unit MAV006S1R2S

MA0071 MA0101 MA0101 MA0162

MAV008S1R2S MAV008T1R2S MAV013T1R2S

Outdoor unit

Power supply (Indoor unit) 220V~, 1Ph, 50Hz 220V~, 1Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-

Power supply (Outdoor unit) 220V~, 1Ph, 50Hz 220V~, 1Ph, 50Hz 220V~, 1Ph, 50Hz 220V~, 1Ph, 50Hz-

Ф16.5

105/117

30/33 40/43 40/43 65/76

107/119 107/119 140/151

956×770×420

842×695×324 945×810×395 945×810×395 904×1,332×414

1,050×900×490 1,050×900×490 1,030×1,456×435

Ф16.5 Ф16.5 Ф16.5mm

mm

mm

kg

kg

Drainage pipe (OD)

Packing (W×H×D)

810×2,030×530 810×2,030×530 810×2,030×530 880×2,030×620mmPacking (W×H×D)

700×1,880×425 700×1,880×425 700×1,880×425 760×1,880×515mmDimension (W×H×D)

Dimension (W×H×D)

Indoor unit

Outdoor unit

Net/gross weight

Weight

5.5

4.95

1,550

3.5

2.5

5.6

27

Ф6/Ф12.7 Ф6/Ф16 Ф6/Ф16 Ф9.52/Ф19

32 18 23

6.7 6.7 9.4

2.5 2.5 2.5

3.5 3.5 4.0

2,050 2,050 2,950

3.003.003.003.00

7.5

6.75 6.75 11.25

7.5 12.5

Cooling

Total capacity kW

kW

kW

kW

A

mm

W/W

kg/h

Sensible capacity

EER

Air volume

Rated input

Humidification capacity

Rated current

Size (Liquid/gas)Rfrigerant pipe

Elect. heater input

m3/h

Notes:1. The nominal cooling capacity is based on the following conditons: Indoor temperature: 24°CDB, 17°CWB; Outdoor temperature: 35°CDB.2. If the refrigerant pipe length is less than 40m and more than 20m, the long-pipe accessories is necessary.3. Specifications are subject to change without prior notice for product improvement.

Front delivery, front intake 5.5kW, 7.5kW 12.5kW, 17kW

R410AR410A R22R22

Outdoor ambient temperature range:

-15°C~48°C

Indoor ambient temperature range:

0°C~40°C

Indoor unit MAV006S1N2S

MA0071N MA0101N MA0162N MA0212N

MAV008T1N2S MAV013T1N2S MAV018T1N2S

Outdoor unit

Power supply (Indoor unit) 220V~, 1Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-

Power supply (Outdoor unit) 220V~, 1Ph, 50Hz 220V~, 1Ph, 50Hz 220V~, 1Ph, 50Hz 220V~, 1Ph, 50Hz-

Ф16.5

105/117

30/33 40/43 65/76 89/106

107/119 140/151 190/208

956×770×420

842×695×324 945×810×395 904×1,332×414 1,120×1,558×528

1,050×900×490 1,030×1,456×435 1,270×1,720×565

Ф16.5 Ф16.5 Ф16.5mm

mm

mm

kg

kg

Drainage pipe (OD)

Packing (W×H×D)

810×2,030×530 810×2,030×530 880×2,030×620 920×2,030×775mmPacking (W×H×D)

700×1,880×425 700×1,880×425 760×1,880×515 800×1,880×670mmDimension (W×H×D)

Dimension (W×H×D)

Indoor unit

Outdoor unit

Net/gross weight

Weight

5.5

4.95

1,550

3.5

2.5

5.6

27

Ф6/Ф12.7 Ф6/Ф16 Ф9.52/Ф19 Ф9.52/Ф19

18 23 26

6.7 9.4 11.2

2.5 2.5 2.5

3.5 4.0 4.0

2,050 2,950 4,500

2.903.002.902.91

7.45

6.75 11.25 15.3

12.5 17.0

Cooling

Total capacity kW

kW

kW

kW

A

mm

W/W

kg/h

Sensible capacity

EER

Air volume

Rated input

Humidification capacity

Rated current

Size (Liquid/gas)Rfrigerant pipe

Elect. heater input

m3/h

Precision A

C

Precision A

C

Page 14: 1508-1T1412 - Midea · 1508-1T1412 COMMERCIAL AIR ... 2014 Launched the All DC Inverter V5X globally ... Midea can supply this kind of precision air conditioner, the Micool and MDP

13 14

Indoor unit MAU070T2N1S1 MAU080T2N1S1 MAU090T2N1S1

MA0601N (×2) MA0752N (×2) MA0982N (×2)Outdoor unit (×Quantity)

Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-

mm

kg

kg

Dimension (W×H×D)

Dimension (W×H×D) [1]

Dimension (W×H×D) [2]

Indoor unit

Outdoor unit

Net/gross weight

Net weight

71.5

65.78

42.0

19,600

12

10

R410A

935/1,125 950/1,140 960/1,150

1,660×1,290×690 1,980×1,290×690

220/330170/300150/260

2,685×1,971×8702,685×1,971×8702,685×1,971×870

2,480×1,050×1,2901,660×1,050×1,290 1,980×1,050×1,290

2,480×1,290×690

R410A R410A

10 10

12 12

22,200 23,800

48.0 55.0

98.085.074.0

78.8

70.92 81.09

90.1Cooling

Total capacity kW

kW

kW

-

A

mm

Packing (W×H×D) 2,805×2,160×9952,805×2,160×9952,805×2,160×995mm

Packing (W×H×D) 2,604×1,446×8242,200×1,475×9401,838×1,470×910mm

mm

kW

kg/h

Sensible capacity

Air volume

Rated input

Humidification capacity

Rated current

Refrigerant type

Elect. heater input

m3/h

Indoor unit MAU040T2N1S1 MAU045T1N1S1 MAU050T2N1S1 MAU060T2N1S1

MA0331N (×2) MA0752N (×1) MA0431N (×2) MA0541N (×2)Outdoor unit (×Quantity)

Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-

mm

kg

kg

Dimension (W×H×D)

Dimension (W×H×D) [1]

Dimension (W×H×D) [2]

Indoor unit

Outdoor unit

Net/gross weight

Net weight

40.3

37.08

32.0

10,980

9

10

R410A

620/770 565/715 670/820 680/830

1,470×988×690 1,980×1,290×690

140/240105/210170/300105/190

1,790×1,971×870 1,790×1,971×8701,790×1,971×8701,790×1,971×870

1,470×1,050×9881,470×1,050×988 1,980×1,050×1,290 1,660×1,050×1,290

1,470×988×690 1,660×1,290×690

R410A R410A R410A

10 10 10

9 9 9

12,030 13,500 16,200

33.0 36.0 39.0

70.065.062.060.0

45.3

40.77 45.99 53.01

51.1 58.9Cooling

Total capacity kW

kW

kW

-

A

mm

Packing (W×H×D) 1,910×2,155×985 1,910×2,155×9851,910×2,155×9851,910×2,155×985mm

Packing (W×H×D) 1,700×1,190×940 1,838×1,470×9102,200×1,475×9401,700×1,990×940mm

mm

kW

kg/h

Sensible capacity

Air volume

Rated input

Humidification capacity

Rated current

Refrigerant type

Elect. heater input

m3/h

Specification (R410A, Top delivery/front intake)Indoor unit MAU020T1N1S1 MAU025T1N1S1 MAU030T1N1S1 MAU035T1N1S1

MA0331N (×1) MA0431N (×1) MA0541N (×1) MA0601N (×1)Outdoor unit (×Quantity)

Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-

mm

kg

kg

Dimension (W×H×D)

Dimension (W×H×D) [1]

Dimension (W×H×D) [2]

Indoor unit

Outdoor unit

Net/gross weight

Net weight

20.2

18.58

15.0

6,125

6

5

R410A

340/425 365/445 370/450 510/620

1,470×988×690 1,470×988×690

150/260140/240105/210105/190

895×1,971×870 1,400×1,971×870895×1,971×870895×1,971×870

1,660×1,050×1,2901,470×1,050×988 1,470×1,050×988 1,660×1,050×1,290

1,660×1,290×690 1,660×1,290×690

R410A R410A R410A

5 5 5

6 6 6

6,810 8,525 10,000

16.5 18.5 25.0

46.033.030.026.8

25.6

23.04 26.55 32.20

29.7 35.0Cooling

Total capacity kW

kW

kW

-

A

mm

Packing (W×H×D) 1,015×2,150×970 1,520×2,155×9851,015×2,150×9701,015×2,150×970mm

Packing (W×H×D) 1,838×1,470×910 1,838×1,470×9101,700×1,190×9401,700×1,190×940mm

mm

kW

kg/h

Sensible capacity

Air volume

Rated input

Humidification capacity

Rated current

Refrigerant type

Elect. heater input

m3/h

Indoor unit MAD070T2N1S1 MAD080T2N1S1 MAD090T2N1S1

MA0601N (×2) MA0752N (×2) MA0982N (×2)Outdoor unit (×Quantity)

Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-

mm

kg

kg

Dimension (W×H×D)

Dimension (W×H×D) [1]

Dimension (W×H×D) [2]

Indoor unit

Outdoor unit

Net/gross weight

Net weight

71.1

67.55

42.0

20,800

12

10

R410A

890/1,080 905/1,095 915/1,105

1,660×1,290×690 1,980×1,290×690

220/330170/300150/260

2,685×1,971×8702,685×1,971×8702,685×1,971×870

2,480×1,050×1,2901,660×1,050×1,290 1,980×1,050×1,290

2,480×1,290×690

R410A R410A

10 10

12 12

23,300 24,800

48.0 55.0

98.085.074.0

81.1

73.80 81.09

90.1Cooling

Total capacity kW

kW

kW

-

A

mm

Packing (W×H×D) 2,805×2,160×9952,805×2,160×9952,805×2,160×995mm

Packing (W×H×D) 2,604×1,446×8242,200×1,475×9401,838×1,470×910mm

mm

kW

kg/h

Sensible capacity

Air volume

Rated input

Humidification capacity

Rated current

Refrigerant type

Elect. heater input

m3/h

Indoor unit MAD040T2N1S1 MAD045T1N1S1 MAD050T2N1S1 MAD060T2N1S1

MA0331N (×2) MA0752N (×1) MA0431N (×2) MA0541N (×2)Outdoor unit (×Quantity)

Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-

mm

kg

kg

Dimension (W×H×D)

Dimension (W×H×D) [1]

Dimension (W×H×D) [2]

Indoor unit

Outdoor unit

Net/gross weight

Net weight

40.3

38.29

32.0

11,980

9

10

R410A

610/760 560/710 660/810 670/820

1,470×988×690 1,980×1,290×690

140/240105/210170/300105/190

1,790×1,971×870 1,790×1,971×8701,790×1,971×8701,790×1,971×870

1,470×1,050×9881,470×1,050×988 1,980×1,050×1,290 1,660×1,050×1,290

1,470×988×690 1,660×1,290×690

R410A R410A R410A

10 10 10

9 9 9

13,030 14,500 17,000

33.0 36.0 39.0

70.065.062.060.0

44.9

41.31 45.23 53.19

49.7 59.1Cooling

Total capacity kW

kW

kW

-

A

mm

Packing (W×H×D) 1,910×2,155×985 1,910×2,155×9851,910×2,155×9851,910×2,155×985mm

Packing (W×H×D) 1,700×1,190×940 1,838×1,470×9102,200×1,475×9401,700×1,190×940mm

mm

kW

kg/h

Sensible capacity

Air volume

Rated input

Humidification capacity

Rated current

Refrigerant type

Elect. heater input

m3/h

Specification (R410A, Underfloor delivery/top intake)Indoor unit MAD020T1N1S1 MAD025T1N1S1 MAD030T1N1S1 MAD035T1N1S1

MA0331N (×1) MA0431N (×1) MA0541N (×1) MA0601N (×1)Outdoor unit (×Quantity)

Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-

mm

kg

kg

Dimension (W×H×D)

Dimension (W×H×D) [1]

Dimension (W×H×D) [2]

Indoor unit

Outdoor unit

Net/gross weight

Net weight

20.2

18.58

15.0

6,225

6

5

R410A

340/425 360/440 365/445 500/610

1,470×988×690 1,470×988×690

150/260140/240105/210105/190

895×1,971×870 1,400×1,971×870895×1,971×870895×1,971×870

1,660×1,050×1,2901,470×1,050×988 1,470×1,050×988 1,660×1,050×1,290

1,660×1,290×690 1,660×1,290×690

R410A R410A R410A

5 5 5

6 6 6

7,010 8,825 10,400

16.5 18.5 25

46333026.8

26.0

23.92 27.81 31.28

30.9 34.0Cooling

Total capacity kW

kW

kW

-

A

mm

Packing (W×H×D) 1,015×2,150×970 1,520×2,155×9851,015×2,150×9701,015×2,150×970mm

Packing (W×H×D) 1,838×1,470×910 1,838×1,470×9101,700×1,190×9401,700×1,190×940mm

mm

kW

kg/h

Sensible capacity

Air volume

Rated input

Humidification capacity

Rated current

Refrigerant type

Elect. heater input

m3/h

Precision A

C

Precision A

C

Page 15: 1508-1T1412 - Midea · 1508-1T1412 COMMERCIAL AIR ... 2014 Launched the All DC Inverter V5X globally ... Midea can supply this kind of precision air conditioner, the Micool and MDP

13 14

Indoor unit MAU070T2N1S1 MAU080T2N1S1 MAU090T2N1S1

MA0601N (×2) MA0752N (×2) MA0982N (×2)Outdoor unit (×Quantity)

Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-

mm

kg

kg

Dimension (W×H×D)

Dimension (W×H×D) [1]

Dimension (W×H×D) [2]

Indoor unit

Outdoor unit

Net/gross weight

Net weight

71.5

65.78

42.0

19,600

12

10

R410A

935/1,125 950/1,140 960/1,150

1,660×1,290×690 1,980×1,290×690

220/330170/300150/260

2,685×1,971×8702,685×1,971×8702,685×1,971×870

2,480×1,050×1,2901,660×1,050×1,290 1,980×1,050×1,290

2,480×1,290×690

R410A R410A

10 10

12 12

22,200 23,800

48.0 55.0

98.085.074.0

78.8

70.92 81.09

90.1Cooling

Total capacity kW

kW

kW

-

A

mm

Packing (W×H×D) 2,805×2,160×9952,805×2,160×9952,805×2,160×995mm

Packing (W×H×D) 2,604×1,446×8242,200×1,475×9401,838×1,470×910mm

mm

kW

kg/h

Sensible capacity

Air volume

Rated input

Humidification capacity

Rated current

Refrigerant type

Elect. heater input

m3/h

Indoor unit MAU040T2N1S1 MAU045T1N1S1 MAU050T2N1S1 MAU060T2N1S1

MA0331N (×2) MA0752N (×1) MA0431N (×2) MA0541N (×2)Outdoor unit (×Quantity)

Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-

mm

kg

kg

Dimension (W×H×D)

Dimension (W×H×D) [1]

Dimension (W×H×D) [2]

Indoor unit

Outdoor unit

Net/gross weight

Net weight

40.3

37.08

32.0

10,980

9

10

R410A

620/770 565/715 670/820 680/830

1,470×988×690 1,980×1,290×690

140/240105/210170/300105/190

1,790×1,971×870 1,790×1,971×8701,790×1,971×8701,790×1,971×870

1,470×1,050×9881,470×1,050×988 1,980×1,050×1,290 1,660×1,050×1,290

1,470×988×690 1,660×1,290×690

R410A R410A R410A

10 10 10

9 9 9

12,030 13,500 16,200

33.0 36.0 39.0

70.065.062.060.0

45.3

40.77 45.99 53.01

51.1 58.9Cooling

Total capacity kW

kW

kW

-

A

mm

Packing (W×H×D) 1,910×2,155×985 1,910×2,155×9851,910×2,155×9851,910×2,155×985mm

Packing (W×H×D) 1,700×1,190×940 1,838×1,470×9102,200×1,475×9401,700×1,990×940mm

mm

kW

kg/h

Sensible capacity

Air volume

Rated input

Humidification capacity

Rated current

Refrigerant type

Elect. heater input

m3/h

Specification (R410A, Top delivery/front intake)Indoor unit MAU020T1N1S1 MAU025T1N1S1 MAU030T1N1S1 MAU035T1N1S1

MA0331N (×1) MA0431N (×1) MA0541N (×1) MA0601N (×1)Outdoor unit (×Quantity)

Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-

mm

kg

kg

Dimension (W×H×D)

Dimension (W×H×D) [1]

Dimension (W×H×D) [2]

Indoor unit

Outdoor unit

Net/gross weight

Net weight

20.2

18.58

15.0

6,125

6

5

R410A

340/425 365/445 370/450 510/620

1,470×988×690 1,470×988×690

150/260140/240105/210105/190

895×1,971×870 1,400×1,971×870895×1,971×870895×1,971×870

1,660×1,050×1,2901,470×1,050×988 1,470×1,050×988 1,660×1,050×1,290

1,660×1,290×690 1,660×1,290×690

R410A R410A R410A

5 5 5

6 6 6

6,810 8,525 10,000

16.5 18.5 25.0

46.033.030.026.8

25.6

23.04 26.55 32.20

29.7 35.0Cooling

Total capacity kW

kW

kW

-

A

mm

Packing (W×H×D) 1,015×2,150×970 1,520×2,155×9851,015×2,150×9701,015×2,150×970mm

Packing (W×H×D) 1,838×1,470×910 1,838×1,470×9101,700×1,190×9401,700×1,190×940mm

mm

kW

kg/h

Sensible capacity

Air volume

Rated input

Humidification capacity

Rated current

Refrigerant type

Elect. heater input

m3/h

Indoor unit MAD070T2N1S1 MAD080T2N1S1 MAD090T2N1S1

MA0601N (×2) MA0752N (×2) MA0982N (×2)Outdoor unit (×Quantity)

Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-

mm

kg

kg

Dimension (W×H×D)

Dimension (W×H×D) [1]

Dimension (W×H×D) [2]

Indoor unit

Outdoor unit

Net/gross weight

Net weight

71.1

67.55

42.0

20,800

12

10

R410A

890/1,080 905/1,095 915/1,105

1,660×1,290×690 1,980×1,290×690

220/330170/300150/260

2,685×1,971×8702,685×1,971×8702,685×1,971×870

2,480×1,050×1,2901,660×1,050×1,290 1,980×1,050×1,290

2,480×1,290×690

R410A R410A

10 10

12 12

23,300 24,800

48.0 55.0

98.085.074.0

81.1

73.80 81.09

90.1Cooling

Total capacity kW

kW

kW

-

A

mm

Packing (W×H×D) 2,805×2,160×9952,805×2,160×9952,805×2,160×995mm

Packing (W×H×D) 2,604×1,446×8242,200×1,475×9401,838×1,470×910mm

mm

kW

kg/h

Sensible capacity

Air volume

Rated input

Humidification capacity

Rated current

Refrigerant type

Elect. heater input

m3/h

Indoor unit MAD040T2N1S1 MAD045T1N1S1 MAD050T2N1S1 MAD060T2N1S1

MA0331N (×2) MA0752N (×1) MA0431N (×2) MA0541N (×2)Outdoor unit (×Quantity)

Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-

mm

kg

kg

Dimension (W×H×D)

Dimension (W×H×D) [1]

Dimension (W×H×D) [2]

Indoor unit

Outdoor unit

Net/gross weight

Net weight

40.3

38.29

32.0

11,980

9

10

R410A

610/760 560/710 660/810 670/820

1,470×988×690 1,980×1,290×690

140/240105/210170/300105/190

1,790×1,971×870 1,790×1,971×8701,790×1,971×8701,790×1,971×870

1,470×1,050×9881,470×1,050×988 1,980×1,050×1,290 1,660×1,050×1,290

1,470×988×690 1,660×1,290×690

R410A R410A R410A

10 10 10

9 9 9

13,030 14,500 17,000

33.0 36.0 39.0

70.065.062.060.0

44.9

41.31 45.23 53.19

49.7 59.1Cooling

Total capacity kW

kW

kW

-

A

mm

Packing (W×H×D) 1,910×2,155×985 1,910×2,155×9851,910×2,155×9851,910×2,155×985mm

Packing (W×H×D) 1,700×1,190×940 1,838×1,470×9102,200×1,475×9401,700×1,190×940mm

mm

kW

kg/h

Sensible capacity

Air volume

Rated input

Humidification capacity

Rated current

Refrigerant type

Elect. heater input

m3/h

Specification (R410A, Underfloor delivery/top intake)Indoor unit MAD020T1N1S1 MAD025T1N1S1 MAD030T1N1S1 MAD035T1N1S1

MA0331N (×1) MA0431N (×1) MA0541N (×1) MA0601N (×1)Outdoor unit (×Quantity)

Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-

mm

kg

kg

Dimension (W×H×D)

Dimension (W×H×D) [1]

Dimension (W×H×D) [2]

Indoor unit

Outdoor unit

Net/gross weight

Net weight

20.2

18.58

15.0

6,225

6

5

R410A

340/425 360/440 365/445 500/610

1,470×988×690 1,470×988×690

150/260140/240105/210105/190

895×1,971×870 1,400×1,971×870895×1,971×870895×1,971×870

1,660×1,050×1,2901,470×1,050×988 1,470×1,050×988 1,660×1,050×1,290

1,660×1,290×690 1,660×1,290×690

R410A R410A R410A

5 5 5

6 6 6

7,010 8,825 10,400

16.5 18.5 25

46333026.8

26.0

23.92 27.81 31.28

30.9 34.0Cooling

Total capacity kW

kW

kW

-

A

mm

Packing (W×H×D) 1,015×2,150×970 1,520×2,155×9851,015×2,150×9701,015×2,150×970mm

Packing (W×H×D) 1,838×1,470×910 1,838×1,470×9101,700×1,190×9401,700×1,190×940mm

mm

kW

kg/h

Sensible capacity

Air volume

Rated input

Humidification capacity

Rated current

Refrigerant type

Elect. heater input

m3/h

Precision A

C

Precision A

C

Page 16: 1508-1T1412 - Midea · 1508-1T1412 COMMERCIAL AIR ... 2014 Launched the All DC Inverter V5X globally ... Midea can supply this kind of precision air conditioner, the Micool and MDP

15 16

Indoor unit MAU070T2R1S3 MAU080T2R1S3 MAU090T2R1S3

MA0601 (×2) MA0752 (×2) MA0982 (×2)Outdoor unit (×Quantity)

Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-

mm

kg

kg

Dimension (W×H×D)

Dimension (W×H×D) [1]

Dimension (W×H×D) [2]

Indoor unit

Outdoor unit

Net/gross weight

Net weight

71.5

65.78

42.0

19,600

12

10

R22

935/1,125 950/1,140 960/1,150

1,660×1,290×690 1,980×1,290×690

220/330170/300150/260

2,685×1,971×8702,685×1,971×8702,685×1,971×870

2,480×1,050×1,2901,660×1,050×1,290 1,980×1,050×1,290

2,480×1,290×690

R22 R22

10 10

12 12

22,200 23,800

48.0 55.0

98.085.074.0

78.8

70.92 81.09

90.1Cooling

Total capacity kW

kW

kW

-

A

mm

Packing (W×H×D) 2,805×2,160×9952,805×2,160×9952,805×2,160×995mm

Packing (W×H×D) 2,604×1,446×8242,200×1,475×9401,838×1,470×910mm

mm

kW

kg/h

Sensible capacity

Air volume

Rated input

Humidification capacity

Rated current

Refrigerant type

Elect. heater input

m3/h

Indoor unit MAU040T2R1S3 MAU045T1R1S3 MAU050T2R1S3 MAU060T2R1S3

MA0331 (×2) MA0752 (×1) MA0431 (×2) MA0541 (×2)Outdoor unit (×Quantity)

Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-

mm

kg

kg

Dimension (W×H×D)

Dimension (W×H×D) [1]

Dimension (W×H×D) [2]

Indoor unit

Outdoor unit

Net/gross weight

Net weight

40.3

37.08

32.0

10,980

9

10

R22

620/770 565/715 670/820 680/830

1,470×988×690 1,980×1,290×690

140/240105/210170/300105/190

1,790×1,971×870 1,790×1,971×8701,790×1,971×8701,790×1,971×870

1,470×1,050×9881,470×1,050×988 1,980×1,050×1,290 1,660×1,050×1,290

1,470×988×690 1,660×1,290×690

R22 R22 R22

10 10 10

9 9 9

12,030 13,500 16,200

33.0 36.0 39.0

70.065.062.060.0

45.3

40.77 45.99 53.01

51.1 58.9Cooling

Total capacity kW

kW

kW

-

A

mm

Packing (W×H×D) 1,910×2,155×985 1,910×2,155×9851,910×2,155×9851,910×2,155×985mm

Packing (W×H×D) 1,700×1,190×940 1,838×1,470×9102,200×1,475×9401,700×1,990×940mm

mm

kW

kg/h

Sensible capacity

Air volume

Rated input

Humidification capacity

Rated current

Refrigerant type

Elect. heater input

m3/h

Specification (R22, Top delivery/front intake)Indoor unit MAU020T1R1S1 MAU025T1R1S3 MAU030T1R1S3 MAU035T1R1S3

MA0331 (×1) MA0431 (×1) MA0541 (×1) MA0601 (×1)Outdoor unit (×Quantity)

Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-

mm

kg

kg

Dimension (W×H×D)

Dimension (W×H×D) [1]

Dimension (W×H×D) [2]

Indoor unit

Outdoor unit

Net/gross weight

Net weight

20.2

18.58

15.0

6,125

6

5

R22

340/425 365/445 370/450 510/620

1,470×988×690 1,470×988×690

150/260140/240105/210105/190

895×1,971×870 1,400×1,971×870895×1,971×870895×1,971×870

1,660×1,050×1,2901,470×1,050×988 1,470×1,050×988 1,660×1,050×1,290

1,660×1,290×690 1,660×1,290×690

R22 R22 R22

5 5 5

6 6 6

6,810 8,525 10,000

16.5 18.5 25.0

46.033.030.026.8

25.6

23.04 26.55 32.20

29.7 35.0Cooling

Total capacity kW

kW

kW

-

A

mm

Packing (W×H×D) 1,015×2,150×970 1,520×2,155×9851,015×2,150×9701,015×2,150×970mm

Packing (W×H×D) 1,838×1,470×910 1,838×1,470×9101,700×1,190×9401,700×1,190×940mm

mm

kW

kg/h

Sensible capacity

Air volume

Rated input

Humidification capacity

Rated current

Refrigerant type

Elect. heater input

m3/h

Indoor unit MAD070T2R1S3 MAD080T2R1S3 MAD090T2R1S3

MA0601 (×2) MA0752 (×2) MA0982 (×2)Outdoor unit (×Quantity)

Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-

mm

kg

kg

Dimension (W×H×D)

Dimension (W×H×D) [1]

Dimension (W×H×D) [2]

Indoor unit

Outdoor unit

Net/gross weight

Net weight

71.1

67.55

42.0

20,800

12

10

R22

890/1,080 905/1,095 915/1,105

1,660×1,290×690 1,980×1,290×690

220/330170/300150/260

2,685×1,971×8702,685×1,971×8702,685×1,971×870

2,480×1,050×1,2901,660×1,050×1,290 1,980×1,050×1,290

2,480×1,290×690

R22 R22

10 10

12 12

23,300 24,800

48.0 55.0

98.085.074.0

81.1

73.80 81.09

90.1Cooling

Total capacity kW

kW

kW

-

A

mm

Packing (W×H×D) 2,805×2,160×9952,805×2,160×9952,805×2,160×995mm

Packing (W×H×D) 2,604×1,446×8242,200×1,475×9401,838×1,470×910mm

mm

kW

kg/h

Sensible capacity

Air volume

Rated input

Humidification capacity

Rated current

Refrigerant type

Elect. heater input

m3/h

Indoor unit MAD040T2R1S3 MAD045T1R1S3 MAD050T2R1S3 MAD060T2R1S3

MA0331 (×2) MA0752 (×1) MA0431 (×2) MA0541 (×2)Outdoor unit (×Quantity)

Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-

mm

kg

kg

Dimension (W×H×D)

Dimension (W×H×D) [1]

Dimension (W×H×D) [2]

Indoor unit

Outdoor unit

Net/gross weight

Net weight

40.3

38.29

32.0

11,980

9

10

R22

610/760 560/710 660/810 670/820

1,470×988×690 1,980×1,290×690

140/240105/210170/300105/190

1,790×1,971×870 1,790×1,971×8701,790×1,971×8701,790×1,971×870

1,470×1,050×9881,470×1,050×988 1,980×1,050×1,290 1,660×1,050×1,290

1,470×988×690 1,660×1,290×690

R22 R22 R22

10 10 10

9 9 9

13,030 14,500 17,000

33.0 36.0 39.0

70.065.062.060.0

44.9

41.31 45.23 53.19

49.7 59.1Cooling

Total capacity kW

kW

kW

-

A

mm

Packing (W×H×D) 1,910×2,155×985 1,910×2,155×9851,910×2,155×9851,910×2,155×985mm

Packing (W×H×D) 1,700×1,190×940 1,838×1,470×9102,200×1,475×9401,700×1,190×940mm

mm

kW

kg/h

Sensible capacity

Air volume

Rated input

Humidification capacity

Rated current

Refrigerant type

Elect. heater input

m3/h

Specification (R22, Underfloor delivery/top intake)Indoor unit MAD020T1R1S1 MAD025T1R1S3 MAD030T1R1S3 MAD035T1R1S3

MA0331 (×1) MA0431 (×1) MA0541 (×1) MA0601 (×1)Outdoor unit (×Quantity)

Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-

mm

kg

kg

Dimension (W×H×D)

Dimension (W×H×D) [1]

Dimension (W×H×D) [2]

Indoor unit

Outdoor unit

Net/gross weight

Net weight

20.2

18.58

15.0

6,225

6

5

R22

340/425 360/440 365/445 500/610

1,470×988×690 1,470×988×690

150/260140/240105/210105/190

895×1,971×870 1,400×1,971×870895×1,971×870895×1,971×870

1,660×1,050×1,2901,470×1,050×988 1,470×1,050×988 1,660×1,050×1,290

1,660×1,290×690 1,660×1,290×690

R22 R22 R22

5 5 5

6 6 6

7,010 8,825 10,400

16.5 18.5 25.0

46.033.030.026.8

26.0

23.92 27.81 31.28

30.9 34.0Cooling

Total capacity kW

kW

kW

-

A

mm

Packing (W×H×D) 1,015×2,150×970 1,520×2,155×9851,015×2,150×9701,015×2,150×970mm

Packing (W×H×D) 1,838×1,470×910 1,838×1,470×9101,700×1,190×9401,700×1,190×940mm

mm

kW

kg/h

Sensible capacity

Air volume

Rated input

Humidification capacity

Rated current

Refrigerant type

Elect. heater input

m3/h

Precision A

C

Precision A

C

Page 17: 1508-1T1412 - Midea · 1508-1T1412 COMMERCIAL AIR ... 2014 Launched the All DC Inverter V5X globally ... Midea can supply this kind of precision air conditioner, the Micool and MDP

15 16

Indoor unit MAU070T2R1S3 MAU080T2R1S3 MAU090T2R1S3

MA0601 (×2) MA0752 (×2) MA0982 (×2)Outdoor unit (×Quantity)

Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-

mm

kg

kg

Dimension (W×H×D)

Dimension (W×H×D) [1]

Dimension (W×H×D) [2]

Indoor unit

Outdoor unit

Net/gross weight

Net weight

71.5

65.78

42.0

19,600

12

10

R22

935/1,125 950/1,140 960/1,150

1,660×1,290×690 1,980×1,290×690

220/330170/300150/260

2,685×1,971×8702,685×1,971×8702,685×1,971×870

2,480×1,050×1,2901,660×1,050×1,290 1,980×1,050×1,290

2,480×1,290×690

R22 R22

10 10

12 12

22,200 23,800

48.0 55.0

98.085.074.0

78.8

70.92 81.09

90.1Cooling

Total capacity kW

kW

kW

-

A

mm

Packing (W×H×D) 2,805×2,160×9952,805×2,160×9952,805×2,160×995mm

Packing (W×H×D) 2,604×1,446×8242,200×1,475×9401,838×1,470×910mm

mm

kW

kg/h

Sensible capacity

Air volume

Rated input

Humidification capacity

Rated current

Refrigerant type

Elect. heater input

m3/h

Indoor unit MAU040T2R1S3 MAU045T1R1S3 MAU050T2R1S3 MAU060T2R1S3

MA0331 (×2) MA0752 (×1) MA0431 (×2) MA0541 (×2)Outdoor unit (×Quantity)

Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-

mm

kg

kg

Dimension (W×H×D)

Dimension (W×H×D) [1]

Dimension (W×H×D) [2]

Indoor unit

Outdoor unit

Net/gross weight

Net weight

40.3

37.08

32.0

10,980

9

10

R22

620/770 565/715 670/820 680/830

1,470×988×690 1,980×1,290×690

140/240105/210170/300105/190

1,790×1,971×870 1,790×1,971×8701,790×1,971×8701,790×1,971×870

1,470×1,050×9881,470×1,050×988 1,980×1,050×1,290 1,660×1,050×1,290

1,470×988×690 1,660×1,290×690

R22 R22 R22

10 10 10

9 9 9

12,030 13,500 16,200

33.0 36.0 39.0

70.065.062.060.0

45.3

40.77 45.99 53.01

51.1 58.9Cooling

Total capacity kW

kW

kW

-

A

mm

Packing (W×H×D) 1,910×2,155×985 1,910×2,155×9851,910×2,155×9851,910×2,155×985mm

Packing (W×H×D) 1,700×1,190×940 1,838×1,470×9102,200×1,475×9401,700×1,990×940mm

mm

kW

kg/h

Sensible capacity

Air volume

Rated input

Humidification capacity

Rated current

Refrigerant type

Elect. heater input

m3/h

Specification (R22, Top delivery/front intake)Indoor unit MAU020T1R1S1 MAU025T1R1S3 MAU030T1R1S3 MAU035T1R1S3

MA0331 (×1) MA0431 (×1) MA0541 (×1) MA0601 (×1)Outdoor unit (×Quantity)

Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-

mm

kg

kg

Dimension (W×H×D)

Dimension (W×H×D) [1]

Dimension (W×H×D) [2]

Indoor unit

Outdoor unit

Net/gross weight

Net weight

20.2

18.58

15.0

6,125

6

5

R22

340/425 365/445 370/450 510/620

1,470×988×690 1,470×988×690

150/260140/240105/210105/190

895×1,971×870 1,400×1,971×870895×1,971×870895×1,971×870

1,660×1,050×1,2901,470×1,050×988 1,470×1,050×988 1,660×1,050×1,290

1,660×1,290×690 1,660×1,290×690

R22 R22 R22

5 5 5

6 6 6

6,810 8,525 10,000

16.5 18.5 25.0

46.033.030.026.8

25.6

23.04 26.55 32.20

29.7 35.0Cooling

Total capacity kW

kW

kW

-

A

mm

Packing (W×H×D) 1,015×2,150×970 1,520×2,155×9851,015×2,150×9701,015×2,150×970mm

Packing (W×H×D) 1,838×1,470×910 1,838×1,470×9101,700×1,190×9401,700×1,190×940mm

mm

kW

kg/h

Sensible capacity

Air volume

Rated input

Humidification capacity

Rated current

Refrigerant type

Elect. heater input

m3/h

Indoor unit MAD070T2R1S3 MAD080T2R1S3 MAD090T2R1S3

MA0601 (×2) MA0752 (×2) MA0982 (×2)Outdoor unit (×Quantity)

Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-

mm

kg

kg

Dimension (W×H×D)

Dimension (W×H×D) [1]

Dimension (W×H×D) [2]

Indoor unit

Outdoor unit

Net/gross weight

Net weight

71.1

67.55

42.0

20,800

12

10

R22

890/1,080 905/1,095 915/1,105

1,660×1,290×690 1,980×1,290×690

220/330170/300150/260

2,685×1,971×8702,685×1,971×8702,685×1,971×870

2,480×1,050×1,2901,660×1,050×1,290 1,980×1,050×1,290

2,480×1,290×690

R22 R22

10 10

12 12

23,300 24,800

48.0 55.0

98.085.074.0

81.1

73.80 81.09

90.1Cooling

Total capacity kW

kW

kW

-

A

mm

Packing (W×H×D) 2,805×2,160×9952,805×2,160×9952,805×2,160×995mm

Packing (W×H×D) 2,604×1,446×8242,200×1,475×9401,838×1,470×910mm

mm

kW

kg/h

Sensible capacity

Air volume

Rated input

Humidification capacity

Rated current

Refrigerant type

Elect. heater input

m3/h

Indoor unit MAD040T2R1S3 MAD045T1R1S3 MAD050T2R1S3 MAD060T2R1S3

MA0331 (×2) MA0752 (×1) MA0431 (×2) MA0541 (×2)Outdoor unit (×Quantity)

Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-

mm

kg

kg

Dimension (W×H×D)

Dimension (W×H×D) [1]

Dimension (W×H×D) [2]

Indoor unit

Outdoor unit

Net/gross weight

Net weight

40.3

38.29

32.0

11,980

9

10

R22

610/760 560/710 660/810 670/820

1,470×988×690 1,980×1,290×690

140/240105/210170/300105/190

1,790×1,971×870 1,790×1,971×8701,790×1,971×8701,790×1,971×870

1,470×1,050×9881,470×1,050×988 1,980×1,050×1,290 1,660×1,050×1,290

1,470×988×690 1,660×1,290×690

R22 R22 R22

10 10 10

9 9 9

13,030 14,500 17,000

33.0 36.0 39.0

70.065.062.060.0

44.9

41.31 45.23 53.19

49.7 59.1Cooling

Total capacity kW

kW

kW

-

A

mm

Packing (W×H×D) 1,910×2,155×985 1,910×2,155×9851,910×2,155×9851,910×2,155×985mm

Packing (W×H×D) 1,700×1,190×940 1,838×1,470×9102,200×1,475×9401,700×1,190×940mm

mm

kW

kg/h

Sensible capacity

Air volume

Rated input

Humidification capacity

Rated current

Refrigerant type

Elect. heater input

m3/h

Specification (R22, Underfloor delivery/top intake)Indoor unit MAD020T1R1S1 MAD025T1R1S3 MAD030T1R1S3 MAD035T1R1S3

MA0331 (×1) MA0431 (×1) MA0541 (×1) MA0601 (×1)Outdoor unit (×Quantity)

Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-

mm

kg

kg

Dimension (W×H×D)

Dimension (W×H×D) [1]

Dimension (W×H×D) [2]

Indoor unit

Outdoor unit

Net/gross weight

Net weight

20.2

18.58

15.0

6,225

6

5

R22

340/425 360/440 365/445 500/610

1,470×988×690 1,470×988×690

150/260140/240105/210105/190

895×1,971×870 1,400×1,971×870895×1,971×870895×1,971×870

1,660×1,050×1,2901,470×1,050×988 1,470×1,050×988 1,660×1,050×1,290

1,660×1,290×690 1,660×1,290×690

R22 R22 R22

5 5 5

6 6 6

7,010 8,825 10,400

16.5 18.5 25.0

46.033.030.026.8

26.0

23.92 27.81 31.28

30.9 34.0Cooling

Total capacity kW

kW

kW

-

A

mm

Packing (W×H×D) 1,015×2,150×970 1,520×2,155×9851,015×2,150×9701,015×2,150×970mm

Packing (W×H×D) 1,838×1,470×910 1,838×1,470×9101,700×1,190×9401,700×1,190×940mm

mm

kW

kg/h

Sensible capacity

Air volume

Rated input

Humidification capacity

Rated current

Refrigerant type

Elect. heater input

m3/h

Precision A

C

Precision A

C

Page 18: 1508-1T1412 - Midea · 1508-1T1412 COMMERCIAL AIR ... 2014 Launched the All DC Inverter V5X globally ... Midea can supply this kind of precision air conditioner, the Micool and MDP

17

Base station AC

FeaturesBase station solutionsBase station is normally used in the context of mobile telephony, wireless computer networking and other wireless communications and in land surveying. Telecommunication system usually using containers, machines rooms faces special challenges on air conditioning. Normally the equipments in stations generate heat. So it is important that maintaining a stable temperature is critical to equipments reliability.Midea can supply this kind of air conditioner, split type and compact type. They can control temperature within tight tolerances 24 hours a day.

Base station ACNormal AC

Sensible capacityLatent capacity

Big airflow, high sensible heat ratioAdopt high-temperature-airflow and low-enthalpy design to avoid the threat of condensation in device surface.High-sensible-heat-ratio design, energy is saved.More save, more reliable.

Free cooling functionIndoor side is designed with free cooling function. it can help to save more energy.Down side air supply to take full removal of heat load and eliminating local hot spots.

Indoor sideOutdoor side

Air exchangeouttake

Fresh air intake

Air supplyouttake

Built-in compressor in indoor sideBuilt-in compressor in indoor side, the operating condition of compressor and reliability of system is apparently improved.

Long piping lengthThe outdoor unit is available for installation of any well ventilation location.

Notes: This is only available for split type units.

25mMax. equivalent piping length

Permitted value

10m

5mMax. height drop

Height drop betweenindoor unit and outdoor unit

Outdoor unit is up

Outdoor unit is down

Base station A

C

18

Page 19: 1508-1T1412 - Midea · 1508-1T1412 COMMERCIAL AIR ... 2014 Launched the All DC Inverter V5X globally ... Midea can supply this kind of precision air conditioner, the Micool and MDP

17

Base station AC

FeaturesBase station solutionsBase station is normally used in the context of mobile telephony, wireless computer networking and other wireless communications and in land surveying. Telecommunication system usually using containers, machines rooms faces special challenges on air conditioning. Normally the equipments in stations generate heat. So it is important that maintaining a stable temperature is critical to equipments reliability.Midea can supply this kind of air conditioner, split type and compact type. They can control temperature within tight tolerances 24 hours a day.

Base station ACNormal AC

Sensible capacityLatent capacity

Big airflow, high sensible heat ratioAdopt high-temperature-airflow and low-enthalpy design to avoid the threat of condensation in device surface.High-sensible-heat-ratio design, energy is saved.More save, more reliable.

Free cooling functionIndoor side is designed with free cooling function. it can help to save more energy.Down side air supply to take full removal of heat load and eliminating local hot spots.

Indoor sideOutdoor side

Air exchangeouttake

Fresh air intake

Air supplyouttake

Built-in compressor in indoor sideBuilt-in compressor in indoor side, the operating condition of compressor and reliability of system is apparently improved.

Long piping lengthThe outdoor unit is available for installation of any well ventilation location.

Notes: This is only available for split type units.

25mMax. equivalent piping length

Permitted value

10m

5mMax. height drop

Height drop betweenindoor unit and outdoor unit

Outdoor unit is up

Outdoor unit is down

Base station A

C

18

Page 20: 1508-1T1412 - Midea · 1508-1T1412 COMMERCIAL AIR ... 2014 Launched the All DC Inverter V5X globally ... Midea can supply this kind of precision air conditioner, the Micool and MDP

2019

Wide operating ambient temperature rangeThe operating ambient temperature range of units with free cooling is from -40°C to 45°C.The operating ambient temperature range of units without free cooling is from -15°C to 45°C.

Adopt RS485 standard communication protocol, long-distance centralized control is realized.Bulit-in many protections function and malfunction alarm function, more reliable and stable operation.The limit of upper and lower temperature can be set through the operator in indoor unit to ensure the temperature remains steady in the pre-set temperature range.The function of temperature locked can be used to restricts unintended operation.Multi-functions, include dual-unit-switch function, auto-restart function, standby function, join-in function and rotary function, can be ensure the units keep normally operating in the whole year.

Multi-electronic control technology

Outdoor ambient temperature °C(D.B.)

-40°C

45°C

45°C

-40 -30 -20 -10 10 20 30 40 500

-15°C

Units with free cooling

Units without free cooling

Outdoor ambient temperature

Outdoor ambient temperature

Rotary function

Start operation

Stops

Main Slave Slave Main

Runs RunsMain unit

Slave unit Stops Stops Runs

Join-in function

Start operation Slave unit runs. Slave unit stops.

RunsMain unit

Slave unit

Heat loadincreases.

Heat loadis normal.

Stops Stops Runs

Standby function

Start operation

Stops

Main Slave

RunsMain unit

Slave unit

Error on main unit.

Stops Runs

Base station AC

Split typewith free cooling

OptionalStandard R410AR410AR22R22

5.5kW 13.0kW7.59kW

Split type without free cooling

OptionalStandard R410AR410AR22R22

5.5kW 13.0kW7.59kW

Compact typewith free cooling

OptionalStandard R407CR407CR22R22

6.0kW,7.5kW 12.0kW

Specifications - Compact typeKCD-60L/S-JZ(E1) KCD-75L/S-JZ(E2) KCD-120L/S-JZModel

Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-

mm

kg

Throttle type

Dimension (W×H×D)

Packing (W×H×D)Unit

Net/Gross weight

5.70

6.0

1,824

3.29

1,550

3.45

15

R22

1,025×1,930×675 1,025×1,930×675

270/285205/220205/220

CapillaryCapillaryCapillary

1,250×1,900×6001,000×1,900×600 1,000×1,900×600

1,280×1,930×675

R22 R22

8.2 15.2

3.60 5.90

1,700 2,300

2.90 2.80

3.513.503.35

6.66

7.5

2.580 4,280

9.12

12.0

Cooling

Total capacity kW

kW

kW

-

-

mm

W

kW

W/W

A

Sensible capacity

Elect. heater

Input

EER

Air volume

Rated current

Refrigerant type

Rated input

m3/h

Specifications are subject to change without prior notice for product improvement.

Cooling 28 20 2635

Entering air DB (°C) Entering air WB (°C)Entering air DB (°C)Entering air WB (°C)

Indoor side Outdoor side

Nominal test condition (Temperature)

Base station A

C

Base station A

C

Page 21: 1508-1T1412 - Midea · 1508-1T1412 COMMERCIAL AIR ... 2014 Launched the All DC Inverter V5X globally ... Midea can supply this kind of precision air conditioner, the Micool and MDP

2019

Wide operating ambient temperature rangeThe operating ambient temperature range of units with free cooling is from -40°C to 45°C.The operating ambient temperature range of units without free cooling is from -15°C to 45°C.

Adopt RS485 standard communication protocol, long-distance centralized control is realized.Bulit-in many protections function and malfunction alarm function, more reliable and stable operation.The limit of upper and lower temperature can be set through the operator in indoor unit to ensure the temperature remains steady in the pre-set temperature range.The function of temperature locked can be used to restricts unintended operation.Multi-functions, include dual-unit-switch function, auto-restart function, standby function, join-in function and rotary function, can be ensure the units keep normally operating in the whole year.

Multi-electronic control technology

Outdoor ambient temperature °C(D.B.)

-40°C

45°C

45°C

-40 -30 -20 -10 10 20 30 40 500

-15°C

Units with free cooling

Units without free cooling

Outdoor ambient temperature

Outdoor ambient temperature

Rotary function

Start operation

Stops

Main Slave Slave Main

Runs RunsMain unit

Slave unit Stops Stops Runs

Join-in function

Start operation Slave unit runs. Slave unit stops.

RunsMain unit

Slave unit

Heat loadincreases.

Heat loadis normal.

Stops Stops Runs

Standby function

Start operation

Stops

Main Slave

RunsMain unit

Slave unit

Error on main unit.

Stops Runs

Base station AC

Split typewith free cooling

OptionalStandard R410AR410AR22R22

5.5kW 13.0kW7.59kW

Split type without free cooling

OptionalStandard R410AR410AR22R22

5.5kW 13.0kW7.59kW

Compact typewith free cooling

OptionalStandard R407CR407CR22R22

6.0kW,7.5kW 12.0kW

Specifications - Compact typeKCD-60L/S-JZ(E1) KCD-75L/S-JZ(E2) KCD-120L/S-JZModel

Power supply 380V~, 3Ph, 50Hz380V~, 3Ph, 50Hz 380V~, 3Ph, 50Hz-

mm

kg

Throttle type

Dimension (W×H×D)

Packing (W×H×D)Unit

Net/Gross weight

5.70

6.0

1,824

3.29

1,550

3.45

15

R22

1,025×1,930×675 1,025×1,930×675

270/285205/220205/220

CapillaryCapillaryCapillary

1,250×1,900×6001,000×1,900×600 1,000×1,900×600

1,280×1,930×675

R22 R22

8.2 15.2

3.60 5.90

1,700 2,300

2.90 2.80

3.513.503.35

6.66

7.5

2.580 4,280

9.12

12.0

Cooling

Total capacity kW

kW

kW

-

-

mm

W

kW

W/W

A

Sensible capacity

Elect. heater

Input

EER

Air volume

Rated current

Refrigerant type

Rated input

m3/h

Specifications are subject to change without prior notice for product improvement.

Cooling 28 20 2635

Entering air DB (°C) Entering air WB (°C)Entering air DB (°C)Entering air WB (°C)

Indoor side Outdoor side

Nominal test condition (Temperature)

Base station A

C

Base station A

C

Page 22: 1508-1T1412 - Midea · 1508-1T1412 COMMERCIAL AIR ... 2014 Launched the All DC Inverter V5X globally ... Midea can supply this kind of precision air conditioner, the Micool and MDP

21 22

Specifications - Split type indoor unit with free coolingKF-55L/CX-JZ2(R2) KF-75L/SC-JZ2(R2) KF-130L/SC-JZ2(R2)Model

Power supply 380V~, 3Ph, 50Hz220V~, 1Ph, 50Hz 380V~, 3Ph, 50Hz-

mm

kg

Liquid/Gas pipe size

Dimension (W×H×D)

Packing (W×H×D)Indoor unit

Net/Gross weight

4.51

5.5

1,666

3.30

1,200

2.13

11.7

R22

810×1,920×720 810×1,920×720

134/146114/12496/106

Φ9.52/Φ19.0Φ6.35/Φ16.0Φ6.35/Φ12.7

Electric expansion valveElectric expansion valveElectric expansion valve

855×1,880×690700×1,880×610 700×1,880×610

875×1,920×795

R22 R22

6.7 12.0

3.20 5.30

1,700 2,850

3.30 3.35

6.072

7.59

2.300 3,880

10.4

13.0

Cooling

Total capacity kW

kW

kW

-

-

mm

mm

W

W/W

A

Sensible capacity

Input

EER

Air volume

Rated current

Refrigerant type

Throttle type

Rated input

m3/h

Specifications - Split type indoor unit without free coolingKF-55L/CX-JZ1(R2) KF-75L/SC-JZ1(R2) KF-130L/SC-JZ1(R2)Model

Power supply 380V~, 3Ph, 50Hz220V~, 1Ph, 50Hz 380V~, 3Ph, 50Hz-

mm

kg

Liquid/Gas pipe size

Dimension (W×H×D)

Packing (W×H×D)Indoor unit

Net/Gross weight

4.51

5.5

1,666

3.30

1,200

2.13

11.7

R22

810×1,640×530 810×1,640×530

126/13694.5/103.577/86

Φ9.52/Φ19.0Φ6.35/Φ16.0Φ6.35/Φ12.7

Electric expansion valveElectric expansion valveElectric expansion valve

855×1,660×505700×1,600×425 700×1,600×425

875×1,700×615

R22 R22

6.7 12.0

3.20 5.30

1,700 2,850

3.30 3.35

6.072

7.59

2.300 3,880

10.4

13.0

Cooling

Total capacity kW

kW

kW

-

-

mm

mm

W

W/W

A

Sensible capacity

Input

EER

Air volume

Rated current

Refrigerant type

Throttle type

Rated input

m3/h

Specifications - Universal outdoor unitKF-55W/C-210 KF-75W/C-350 KF-130W/C-610Model

Power supply 220V~, 1Ph, 50Hz220V~, 1Ph, 50Hz 220V~, 1Ph, 50Hz-

mm

kg

Liquid/Gas pipe size

Dimension (W×H×D)

Packing (W×H×D)Outdoor unit

Net/Gross weight

0.46

0.105

R22

2,365

965×755×420 1,050×870×490

65/7339.5/45.627/32

Φ9.52/Φ19.0Φ6.35/Φ16.0Φ6.35/Φ12.7

904×1,332×414842×695×324 945×810×395

1,016×1,377×435

3,600 6,430

0.65

0.170

R22 R22

1.70

0.380Rated input kW

A

mm

mm

W

Rated current

Air volume

Refrigerant type

m3/h

Project references

Base station A

C

Page 23: 1508-1T1412 - Midea · 1508-1T1412 COMMERCIAL AIR ... 2014 Launched the All DC Inverter V5X globally ... Midea can supply this kind of precision air conditioner, the Micool and MDP

21 22

Specifications - Split type indoor unit with free coolingKF-55L/CX-JZ2(R2) KF-75L/SC-JZ2(R2) KF-130L/SC-JZ2(R2)Model

Power supply 380V~, 3Ph, 50Hz220V~, 1Ph, 50Hz 380V~, 3Ph, 50Hz-

mm

kg

Liquid/Gas pipe size

Dimension (W×H×D)

Packing (W×H×D)Indoor unit

Net/Gross weight

4.51

5.5

1,666

3.30

1,200

2.13

11.7

R22

810×1,920×720 810×1,920×720

134/146114/12496/106

Φ9.52/Φ19.0Φ6.35/Φ16.0Φ6.35/Φ12.7

Electric expansion valveElectric expansion valveElectric expansion valve

855×1,880×690700×1,880×610 700×1,880×610

875×1,920×795

R22 R22

6.7 12.0

3.20 5.30

1,700 2,850

3.30 3.35

6.072

7.59

2.300 3,880

10.4

13.0

Cooling

Total capacity kW

kW

kW

-

-

mm

mm

W

W/W

A

Sensible capacity

Input

EER

Air volume

Rated current

Refrigerant type

Throttle type

Rated input

m3/h

Specifications - Split type indoor unit without free coolingKF-55L/CX-JZ1(R2) KF-75L/SC-JZ1(R2) KF-130L/SC-JZ1(R2)Model

Power supply 380V~, 3Ph, 50Hz220V~, 1Ph, 50Hz 380V~, 3Ph, 50Hz-

mm

kg

Liquid/Gas pipe size

Dimension (W×H×D)

Packing (W×H×D)Indoor unit

Net/Gross weight

4.51

5.5

1,666

3.30

1,200

2.13

11.7

R22

810×1,640×530 810×1,640×530

126/13694.5/103.577/86

Φ9.52/Φ19.0Φ6.35/Φ16.0Φ6.35/Φ12.7

Electric expansion valveElectric expansion valveElectric expansion valve

855×1,660×505700×1,600×425 700×1,600×425

875×1,700×615

R22 R22

6.7 12.0

3.20 5.30

1,700 2,850

3.30 3.35

6.072

7.59

2.300 3,880

10.4

13.0

Cooling

Total capacity kW

kW

kW

-

-

mm

mm

W

W/W

A

Sensible capacity

Input

EER

Air volume

Rated current

Refrigerant type

Throttle type

Rated input

m3/h

Specifications - Universal outdoor unitKF-55W/C-210 KF-75W/C-350 KF-130W/C-610Model

Power supply 220V~, 1Ph, 50Hz220V~, 1Ph, 50Hz 220V~, 1Ph, 50Hz-

mm

kg

Liquid/Gas pipe size

Dimension (W×H×D)

Packing (W×H×D)Outdoor unit

Net/Gross weight

0.46

0.105

R22

2,365

965×755×420 1,050×870×490

65/7339.5/45.627/32

Φ9.52/Φ19.0Φ6.35/Φ16.0Φ6.35/Φ12.7

904×1,332×414842×695×324 945×810×395

1,016×1,377×435

3,600 6,430

0.65

0.170

R22 R22

1.70

0.380Rated input kW

A

mm

mm

W

Rated current

Air volume

Refrigerant type

m3/h

Project references

Base station A

C

Page 24: 1508-1T1412 - Midea · 1508-1T1412 COMMERCIAL AIR ... 2014 Launched the All DC Inverter V5X globally ... Midea can supply this kind of precision air conditioner, the Micool and MDP

23 24

China Unicom

Shijiazhuang customs China Mobile

Hebei Provincial Administration of Quality and Technical Supervision

Shenzhen North Railway Station

Project references

Page 25: 1508-1T1412 - Midea · 1508-1T1412 COMMERCIAL AIR ... 2014 Launched the All DC Inverter V5X globally ... Midea can supply this kind of precision air conditioner, the Micool and MDP

1508-1T1412

COMMERCIAL AIR CONDITIONERS

Precision AC / Base Station AC

Precision A

C / B

ase Station A

C

D e a l e r i n f o r m a t i o n

Commercial Air Conditioner Business Units

Midea Group

Add: West Region of Midea Commercial Air Conditioner Department, Industry Avenue,

Beijiao, Shunde, Foshan, Guangdong, P. R. China

Postal code: 528311

Tel: +86-757-26338346 Fax: +86-757-22390205

http://global.midea.com.cn

http://www.midea.com

Note: The data in this book may be changed without notice for further improvement

on quality and performance.

Ver.2014.12