RigLine 24/7™ Support Line: 866.433.4345 | International: +1 281.774.5649 | Fax: 281.774.1940 | E-mail: [email protected] Document ID 14-033 v 1.0 | Copyright © 2014 Canrig Drilling Technology Ltd. All rights reserved. 1 of 6 Model: AC Top Drives Serial #: N/A Mar. 28, 2014 Product Bulletin # TDS-139 PanelView Unit Replacement (Standalone Top Drive System) Issue Allen Bradley no longer manufactures the following Human Machine Interface (HMI) screen models: PanelView 1000 PanelView Plus 1250 with Remote I/O Communication. Damaged units used in a standalone top drive must be upgraded to the more recent PanelView Plus 6 1250 model. Follow the steps below to identify the existing unit and select the parts required to complete the upgrade. Refer to the diagram on Figure 5 on page 6 for additional information. Requirements The new screen will be shipped already programmed, therefore the following information is required. 1. Send to RigLine Support 24/7™ the following: Top drive serial number PLC program running the top drive Ordering the new PanelView Unit 2. Order the required new PanelView Plus 6 1250 unit listed below. Table 1: PanelView Plus 6 1250 Qty Part Number Description 1 AY18938 PanelView Plus 6 1250

Upload: others

Post on 01-Oct-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 14-033 identifying replacement panelview - Nabors Industries

Model: AC Top Drives

Serial #: N/AMar. 28, 2014

Product Bulletin # TDS-139

PanelView Unit Replacement(Standalone Top Drive System)

IssueAllen Bradley no longer manufactures the following Human Machine Interface (HMI) screen models:

• PanelView 1000

• PanelView Plus 1250 with Remote I/O Communication.

Damaged units used in a standalone top drive must be upgraded to the more recent PanelView Plus 6

1250 model. Follow the steps below to identify the existing unit and select the parts required to complete

the upgrade.

Refer to the diagram on Figure 5 on page 6 for additional information.

RequirementsThe new screen will be shipped already programmed, therefore the following information is required.

1. Send to RigLine Support 24/7™ the following:

• Top drive serial number

• PLC program running the top drive

Ordering the new PanelView Unit2. Order the required new PanelView Plus 6 1250 unit listed below.

Table 1: PanelView Plus 6 1250

Qty Part Number Description

1 AY18938 PanelView Plus 6 1250

RigLine 24/7™ Support Line: 866.433.4345 | International: +1 281.774.5649 | Fax: 281.774.1940 | E-mail: [email protected]

Document ID 14-033 v 1.0 | Copyright © 2014 Canrig Drilling Technology Ltd. All rights reserved.

1 of 6

Page 2: 14-033 identifying replacement panelview - Nabors Industries

Model: AC Top Drives

Serial #: N/AMar. 28, 2014

Identifying Existing PanelView Model3. What color is the bezel of the existing PanelView unit?

a. Black (labeled PanelView 1000). See Figure 1 below.

Figure 1: PanelView 1000

When replacing a PanelView 1000 order the following parts:

Continue to “Identifying Installed Processor” on page 4.

Table 2: Power Supply and Mounting Hardware

Qty Part Number Description

1 E11409 Power Supply 24 VDC

1 E11337 DIN Rail, 4”

2 RH-P-10-32-0050-SS 10-32 Screws

2 LW-10-ET-SS Lock Washers

2 E16-1102-010 End Brackets

2 LN-10-32 Lock Nuts

RigLine 24/7™ Support Line: 866.433.4345 | International: +1 281.774.5649 | Fax: 281.774.1940 | E-mail: [email protected]

Document ID 14-033 v 1.0 | Copyright © 2014 Canrig Drilling Technology Ltd. All rights reserved.

2 of 6

Page 3: 14-033 identifying replacement panelview - Nabors Industries

Model: AC Top Drives

Serial #: N/AMar. 28, 2014

b. Gray (labeled PanelView Plus 1250). See Figure 2 below.

Figure 2: PanelView Plus 1250

Figure 3: Back view of HMI Displays

If the existing unit is a PanelView Plus 1250 (display on the left on Figure 3) continue to “Identifying

Installed Processor” on page 4.

If the existing unit is a PanelView Plus 6 1250, part number AY18938 (display on the right on

Figure 3) the procedure is complete. No additional parts are required.

PanelView Plus 1250 PanelView Plus 6 1250Two modules in the back Only one module in the back

RigLine 24/7™ Support Line: 866.433.4345 | International: +1 281.774.5649 | Fax: 281.774.1940 | E-mail: [email protected]

Document ID 14-033 v 1.0 | Copyright © 2014 Canrig Drilling Technology Ltd. All rights reserved.

3 of 6

Page 4: 14-033 identifying replacement panelview - Nabors Industries

Model: AC Top Drives

Serial #: N/AMar. 28, 2014

Identifying Installed ProcessorThe processor SLC 5/03 will not work with the new PanelView Plus 6 1250, therefore a new processor

must be ordered. Follow the steps below to identify if a new processor is required:

4. What processor is installed?

a. SLC 5/03

Figure 4: SLC 5/03 Processor

When replacing a SLC 5/03 processor unit order the following parts:

Continue to “Selecting Required Cable Kit” on page 5.

b. SLC 5/05

No extra parts required. Continue to “Selecting Required Cable Kit” on page 5.

Table 3: SLC 5/05 Processor

Qty Part Number Description

1 N10150 SLC 5/05 Processor

RigLine 24/7™ Support Line: 866.433.4345 | International: +1 281.774.5649 | Fax: 281.774.1940 | E-mail: [email protected]

Document ID 14-033 v 1.0 | Copyright © 2014 Canrig Drilling Technology Ltd. All rights reserved.

4 of 6

Page 5: 14-033 identifying replacement panelview - Nabors Industries

Model: AC Top Drives

Serial #: N/AMar. 28, 2014

Selecting Required Cable KitThe location of the building that contains the processor determines the length of the required cable kit:

5. Where is the building (with the processor) installed?

a. On the ground

Order the following kit:

The procedure is complete.

b. On the rig’s deck

The procedure is complete.

Table 4: 265’ Cable Kit

Qty Part Number Description

1 AY20104-265Kit, Cable, PV1250 Plus 6

upgrade. w/265' Cable

Table 5: 160’ Cable Kit

Qty Part Number Description

1 AY20104-160Kit, Cable, PV1250 Plus 6

upgrade. w/160' Cable

RigLine 24/7™ Support Line: 866.433.4345 | International: +1 281.774.5649 | Fax: 281.774.1940 | E-mail: [email protected]

Document ID 14-033 v 1.0 | Copyright © 2014 Canrig Drilling Technology Ltd. All rights reserved.

5 of 6

Page 6: 14-033 identifying replacement panelview - Nabors Industries

Model: AC Top Drives

Serial #: N/AMar. 28, 2014

Figure 5: Procedure Flowchart

1. TOP DRIVE SERIAL NUMBER2. PLC PROGRAM

ORDER NEWPANELVIEW PLUS 6 1250AY18938

WHATCOLOR

IS THE BEZELOF EXISTING

UNIT?

SLC 5/03

ORDERE11409E11337RH-P-10-32-0050-SSLW-10-ET-SSE16-1102-010LN-10-32

SLC 5/05

WHAT MODELIS THE

PROCESSOR?

BLACK

GRAY

ORDER SLC 5/05N10150

WHERE ISTHE BUILDING

LOCATED?

ORDER 160-FT CABLE KITAY-20104-160

ORDER 265-FT CABLE KITAY-20104-265

PANELVIEW 1000

PANELVIEWPLUS 1250WITH RIO

RIG’S DECK

GROUND

SEND TO RIGLINE SUPPORT 24/7™:

RigLine 24/7™ Support Line: 866.433.4345 | International: +1 281.774.5649 | Fax: 281.774.1940 | E-mail: [email protected]