Vancouver Waste Disposal Facility - Application Licence Amendment
Prepared by Bowman & Associates Pty Ltd Page 56
13.3 APPENDIX C – SOIL TEST RESULTS
![Page 2: 13.3 APPENDIX C SOIL TEST RESULTS · CLAYEY SAND - mottled red / grey DIRECT SHEAR TEST REPORT Residual @ 8 mm Displacement Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol](https://reader030.vdocuments.mx/reader030/viewer/2022040907/5e7e45d4f112da00bd21f0dc/html5/thumbnails/2.jpg)
Brisbane
346A Bilsen Road,
Geebung
QLD 4034
Ph: +61 7 3265 5656
Perth
2 Kimmer Place,
Queens Park
WA 6107
Ph: +61 8 9258 8323Soil Rock Calibration
chrisc 1919
James
Client Report No.
Address PO Box 2059 ROSSMOYNE WA 6148
Project Test Date
Report Date
18020062 18020063 18020064 18020065
Sample 1 Sample 2 Sample 3 Sample 4
Not Supplied Not Supplied Not Supplied Not Supplied
40 53 Not Obtainable Not Obtainable
19 22 Not Obtainable Not Obtainable
Plasticity Index (%) 21 31 Non Plastic Non Plastic
Linear Shrinkage (%) 9.5 * 13.0 * Not Obtainable Not Obtainable
Moisture Content (%) 12.1 19.9 9.3 2.3
Plasticity Index (%)
Linear Shrinkage (%)
Moisture Content (%)
NOTES/REMARKS: The samples were tested oven dried, dry sieved and in a 125-250mm mould.
Sample/s supplied by the client * Cracking occurred + Curling occurred Page 1 of 1 REP30101
Laboratory No. 9926
Depth (m)
Trilab Pty Ltd ABN 25 065 630 506
Reference should be made to Trilab's “Standard Terms and Conditions of Business” for further details.
The results of calibrations and tests performed apply only to the specific instrument or sample at the time of test unless otherwise clearly stated.
Liquid Limit (%)
Plastic Limit (%)
ATTERBERG LIMITS TEST REPORTTest Method: AS 1289 2.1.1, 3.1.1, 3.1.2, 3.2.1, 3.3.1, 3.4.1
Mindijup Landfill
P 18020062-AL
23/02/2018
19/02/2018
Bowman & Associates Pty Ltd
Sample No.
Client ID
Depth (m)
Client ID
Sample No.
Plastic Limit (%)
Liquid Limit (%)
Authorised Signatory
A. Harrap
Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations, and/or measurements included in
this document are traceable to Australian/National Standards.
Tested at Trilab Perth Laboratory.
Authorised Signatory
C. Channon
ACCURATE QUALITY RESULTS FOR TOMORROW'S ENGINEERING
![Page 3: 13.3 APPENDIX C SOIL TEST RESULTS · CLAYEY SAND - mottled red / grey DIRECT SHEAR TEST REPORT Residual @ 8 mm Displacement Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol](https://reader030.vdocuments.mx/reader030/viewer/2022040907/5e7e45d4f112da00bd21f0dc/html5/thumbnails/3.jpg)
Brisbane
346A Bilsen Road,
Geebung
QLD 4034
Ph: +61 7 3265 5656
Perth
2 Kimmer Place,
Queens Park
WA 6107
Ph: +61 8 9258 8323Soil Rock Calibration
chrisc 1919
James
Client Report No.
Address
Project Test Date
Report Date
Sample No. 18020062 18020063 18020064 18020065
Client ID Sample 1 Sample 2 Sample 3 Sample 4
Depth (m) Not Supplied Not Supplied Not Supplied Not Supplied
Moisture (%) 12.1 19.9 9.3 2.3
AS SIEVE SIZE
(mm)
150
75
53
37.5 100
26.5 98
19 97
9.5 97
4.75 97
2.36 97 100 100
1.18 97 99 98 100
0.600 94 99 92 90
0.425 67 96 70 78
0.300 42 94 35 69
0.150 30 83 20 37
0.075 26 68 13 9
NOTES/REMARKS:
Sample/s supplied by the client Page 1 of 1 REP31102
Laboratory No. 9926
PARTICLE SIZE DISTRIBUTION TEST REPORTTest Method: AS 1289 3.6.1, 2.1.1
Mindijup Landfill
P18020062-G
22/02/2018
19/02/2018
Bowman & Associates Pty Ltd
PO Box 2059 ROSSMOYNE WA 6148
PERCENT PASSING
Trilab Pty Ltd ABN 25 065 630 506
Reference should be made to Trilab's “Standard Terms and Conditions of Business” for further details.
The results of calibrations and tests performed apply only to the specific instrument or sample at the time of test unless otherwise clearly stated.
Authorised Signatory
A. Harrap
Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations, and/or measurements included in
this document are traceable to Australian/National Standards.
Tested at Trilab Perth Laboratory.
Authorised Signatory
C. Channon
ACCURATE QUALITY RESULTS FOR TOMORROW'S ENGINEERING
![Page 4: 13.3 APPENDIX C SOIL TEST RESULTS · CLAYEY SAND - mottled red / grey DIRECT SHEAR TEST REPORT Residual @ 8 mm Displacement Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol](https://reader030.vdocuments.mx/reader030/viewer/2022040907/5e7e45d4f112da00bd21f0dc/html5/thumbnails/4.jpg)
Brisbane
346A Bilsen Road,
Geebung
QLD 4034
Ph: +61 7 3265 5656
Perth
2 Kimmer Place,
Queens Park
WA 6107
Ph: +61 8 9258 8323Soil Rock Calibration
chrisc 1919
James
Client Report No.
Address
Project Test Date
Report Date
Client ID Depth (m)
6.00 17.00
1.60 2.00
NOTES/REMARKS: This is a computer generated plot so estimates may show some minor variations
from the results summarised.
Sample/s supplied by the client % Voids based on assumed SG of 2.48 Page 1 of 1 REP31302
Laboratory No. 9926
Sample 1
MOISTURE/DENSITY RELATIONSHIP TEST REPORTTest Method: AS 1289 5.1.1
Mindijup Landfill
P18020062-MDD
22/02/2018
21/02/2018
Not Supplied
Bowman & Associates Pty Ltd
PO Box 2059 ROSSMOYNE WA 6148
Maximum Dry Density (t/m3)
Trilab Pty Ltd ABN 25 065 630 506
Reference should be made to Trilab's “Standard Terms and Conditions of Business” for further details.
The results of calibrations and tests performed apply only to the specific instrument or sample at the time of test unless otherwise clearly stated.
3/19
12.1
Moisture Content (%) 12.1
1.79
Percentage of Oversize/Sieve Size (mm)
Optimum Moisture Content (%)
Authorised Signatory
A. Harrap
1.600
1.650
1.700
1.750
1.800
1.850
1.900
1.950
2.000
6.0 8.0 10.0 12.0 14.0 16.0
Dry
Den
sity
(t/
m3 )
Moisture Content (%)
Test Data MDD at OMC Cubic Spline Interpolation 0% Air Voids 2% Air Voids 4% Air Voids
Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations, and/or measurements included in
this document are traceable to Australian/National Standards.
Tested at Trilab Perth Laboratory.
Authorised Signatory
C. Channon
ACCURATE QUALITY RESULTS FOR TOMORROW'S ENGINEERING
![Page 5: 13.3 APPENDIX C SOIL TEST RESULTS · CLAYEY SAND - mottled red / grey DIRECT SHEAR TEST REPORT Residual @ 8 mm Displacement Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol](https://reader030.vdocuments.mx/reader030/viewer/2022040907/5e7e45d4f112da00bd21f0dc/html5/thumbnails/5.jpg)
Brisbane
346A Bilsen Road,
Geebung
QLD 4034
Ph: +61 7 3265 5656
Perth
2 Kimmer Place,
Queens Park
WA 6107
Ph: +61 8 9258 8323Soil Rock Calibrationchrisc 1919
Client Report No.
Address
Project Test Date
Report Date
Client ID
Description Sample Type
Failure Criteria
Notes/Remarks: Please review the results if the Cohesion is above 2 kPa when plotted with a line of best fit
Note: Area correction based on square sample equation.
Graph not to scale Sample/s supplied by the client Page 1 REP37101
Laboratory No. 9926 The results of calibrations and tests performed apply only to the specific instrument or sample at the time of test unless otherwise clearly stated.
Reference should be made to Trilab's “Standard Terms and Conditions of Business” for further details.Trilab Pty Ltd ABN 25 065 630 506
Three individual soil specimens - Remoulded as
requested by the client (-4.75mm material
tested)
CLAYEY SAND - mottled red / grey
DIRECT SHEAR TEST REPORT
Residual @ 8 mm Displacement
Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol. 2
8/03/2018
1/03/2018
Not SuppliedDepth (m)
Mindijup Landfill
Sample 1
P 18020062- DSBowman & Associates Pty Ltd
PO Box 2059 ROSSMOYNE WA 6148
Authorised Signatory
B. Brash
25 kPa
50.1 kPa
100.1 kPa
0
10
20
30
40
50
60
70
80
0 2 4 6 8 10 12
Sh
ear
Str
es
s (
kP
a)
Relative Displacement (mm)
Shear Stress/Displacement Plot
25 kPa
50.1 kPa 100.1 kPa
-0.1
0
0.1
0.2
0.3
0.4
0.5
0 2 4 6 8 10 12
Vert
ical D
isp
lacem
en
t (m
m)
Relative Displacement (mm)
Vertical Displacement/Relative Displacement Plot
Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations, and/or measurements included in this
document are traceable to Australian/National Standards.
Tested at Trilab Perth Laboratory
Authorised Signatory
C. Channon
ACCURATE QUALITY RESULTS FOR TOMORROW'S ENGINEERING
![Page 6: 13.3 APPENDIX C SOIL TEST RESULTS · CLAYEY SAND - mottled red / grey DIRECT SHEAR TEST REPORT Residual @ 8 mm Displacement Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol](https://reader030.vdocuments.mx/reader030/viewer/2022040907/5e7e45d4f112da00bd21f0dc/html5/thumbnails/6.jpg)
Brisbane
346A Bilsen Road,
Geebung
QLD 4034
Ph: +61 7 3265 5656
Perth
2 Kimmer Place,
Queens Park
WA 6107
Ph: +61 8 9258 8323Soil Rock Calibration
Client Report No.
Address
Project Test Date
Report Date
Client ID
Description Sample Type
Failure Criteria
33.1 5.5 R2
Specimen Condition Shear Stress (kPa)
Specimen Dimensions (mm)
Rate of Strain (mm/min)
Initial Moisture Content (%)
Initial Wet Density(t/m3)
Notes/Remarks: Please review the results if the Cohesion is above 2 kPa when plotted with a line of best fit
Note: Area correction based on square sample equation.
Graph not to scale Sample/s supplied by the client Page 2 REP37101
Laboratory No. 9926
0.008
0.00
Inundated Normal Stress (kPa)
70.7
38.1
100.1
50.1
21.8
DIRECT SHEAR TEST REPORT
Residual @ 8 mm Displacement
Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol. 2
Mindijup Landfill
25.0
Sample 1 Depth (m) Not Supplied
CLAYEY SAND - mottled red / grey Three individual soil specimens - Remoulded as
requested by the client (-4.75mm material
tested)
Stage 1
1/03/2018
8/03/2018
Cohesion (kPa)
P 18020062- DS
1.000
12.1
100*100
The results of calibrations and tests performed apply only to the specific instrument or sample at the time of test unless otherwise clearly stated.
Reference should be made to Trilab's “Standard Terms and Conditions of Business” for further details.Trilab Pty Ltd ABN 25 065 630 506
Stage 3
Stage 2
Shear Angle (o)
PO Box 2059 ROSSMOYNE WA 6148
Bowman & Associates Pty Ltd
Authorised Signatory
B. Brash
0
20
40
60
80
100
0 20 40 60 80 100 120
Sh
ea
r S
tre
ss
(k
Pa
)
Normal Stress (kPa)
Residual - Normal Stress vs Shear Stress
Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations, and/or measurements included in this
document are traceable to Australian/National Standards.
Tested at Trilab Perth Laboratory
Authorised Signatory
C. Channon
ACCURATE QUALITY RESULTS FOR TOMORROW'S ENGINEERING
![Page 7: 13.3 APPENDIX C SOIL TEST RESULTS · CLAYEY SAND - mottled red / grey DIRECT SHEAR TEST REPORT Residual @ 8 mm Displacement Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol](https://reader030.vdocuments.mx/reader030/viewer/2022040907/5e7e45d4f112da00bd21f0dc/html5/thumbnails/7.jpg)
Brisbane
346A Bilsen Road,
Geebung
QLD 4034
Ph: +61 7 3265 5656
Perth
2 Kimmer Place,
Queens Park
WA 6107
Ph: +61 8 9258 8323Soil Rock Calibration
Client Report No.
Address
Project Test Date
Report Date
Client ID
Description Sample Type
Failure Criteria
32.5 8.7 R2
Specimen Condition Shear Stress (kPa)
Specimen Dimensions (mm)
Rate of Strain (mm/min)
Initial Moisture Content (%)
Initial Wet Density(t/m3)
Notes/Remarks: Please review the results if the Cohesion is above 2 kPa when plotted with a line of best fit
Note: Area correction based on square sample equation.
Graph not to scale Sample/s supplied by the client Page 3 REP37101
Laboratory No. 9926
Mindijup Landfill
DIRECT SHEAR TEST REPORT
P 18020062- DS
Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol. 2
Shear Angle (o) 0.999
Bowman & Associates Pty Ltd
Stage 3
Stage 2
Stage 1
Cohesion (kPa)
Normal Stress (kPa)
0.008
12.1
The results of calibrations and tests performed apply only to the specific instrument or sample at the time of test unless otherwise clearly stated.
Reference should be made to Trilab's “Standard Terms and Conditions of Business” for further details.Trilab Pty Ltd ABN 25 065 630 506
39.7
25.3
100.1
50.1
25.0
72.9
0.00
100*100
Inundated
Peak
PO Box 2059 ROSSMOYNE WA 6148
1/03/2018
8/03/2018
Sample 1 Depth (m) Not Supplied
CLAYEY SAND - mottled red / grey Three individual soil specimens - Remoulded as
requested by the client (-4.75mm material
tested)
Authorised Signatory
B. Brash
0
20
40
60
80
100
0 20 40 60 80 100 120
Sh
ea
r S
tre
ss
(k
Pa
)
Normal Stress (kPa)
Peak - Normal Stress vs Shear Stress
Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations, and/or measurements included in this
document are traceable to Australian/National Standards.
Tested at Trilab Perth Laboratory
Authorised Signatory
C. Channon
ACCURATE QUALITY RESULTS FOR TOMORROW'S ENGINEERING
![Page 8: 13.3 APPENDIX C SOIL TEST RESULTS · CLAYEY SAND - mottled red / grey DIRECT SHEAR TEST REPORT Residual @ 8 mm Displacement Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol](https://reader030.vdocuments.mx/reader030/viewer/2022040907/5e7e45d4f112da00bd21f0dc/html5/thumbnails/8.jpg)
Brisbane
10/104 Newmarket Rd,
Windsor
QLD 4030
Ph: +61 7 3357 5535
Perth
2 Kimmer Place,
Queens Park
WA 6107
Ph: +61 8 9258 8323Soil Rock Calibration
chrisc 1919
Client Report No.
Address
Project Test Date
Report Date
Client ID
Description Sample Type
Compaction Method AS1289.5.1.1 - Standard Compaction
Maximum Dry Density (t/m3) Hydraulic Gradient
Optimum Moisture Content (%) Surcharge (kPa)
Placement Moisture Content (%) Head Pressure Applied (kPa)
Moisture Ratio (%) Water Type
Placement Wet Density (t/m3) Percentage Material Retained/Sieve Size (mm)
Density Ratio (%) Sample Height and Diameter (mm)
Remarks: The above specimen was remoulded to a target of 98% of Standard Maximum Dry Density and at Optimum Moisture Content.
Sample/s supplied by client REP36301
PO Box 2059 ROSSMOYNE WA 6148
98.1
The results of calibrations and tests performed apply only to the specific instrument or sample at the time of test unless otherwise clearly stated.
Reference should be made to Trilab's “Standard Terms and Conditions of Business” for further details.
Depth (m) Not Supplied
3 / 19
Distilled
1.97
CLAY SANDY- mottled red / grey
99.7
Trilab Pty Ltd ABN 25 065 630 506
Laboratory No. 9926
116.5 / 101.1
PERMEABILITY k(20) =
Page: 1 of 1
4.5E-10 (m/sec)
PERMEABILITY BY FALLING HEAD TEST REPORT
Test Method AS 1289 6.7.2, 5.1.1 , KH2 (Based on K H Head (1988) Manual of Laboratory Testing,10.7)
10.1
3.0
11.58
RESULTS OF TESTING
1.79
12.1
12.1
Mindijup Landfill
Remoulded Soil Specimen
23/02/2018
2/03/2018
P 18020062-FHPT
Sample 1
Bowman & Associates Pty Ltd
Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations, and/or measurements included in
this document are traceable to Australian/National Standards.
Tested at Trilab Perth Laboratory
1.000E-10
2.000E-10
3.000E-10
4.000E-10
5.000E-10
6.000E-10
7.000E-10
8.000E-10
9.000E-10
0 1000 2000 3000 4000 5000 6000 7000
k20
(m
/sec
)
Elapsed Time of Test (mins)
Permeability
Authorised Signatory
C. Channon
ACCURATE QUALITY RESULTS FOR TOMORROW'S ENGINEERING
![Page 9: 13.3 APPENDIX C SOIL TEST RESULTS · CLAYEY SAND - mottled red / grey DIRECT SHEAR TEST REPORT Residual @ 8 mm Displacement Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol](https://reader030.vdocuments.mx/reader030/viewer/2022040907/5e7e45d4f112da00bd21f0dc/html5/thumbnails/9.jpg)
Brisbane
346A Bilsen Road,
Geebung
QLD 4034
Ph: +61 7 3265 5656
Perth
2 Kimmer Place,
Queens Park
WA 6107
Ph: +61 8 9258 8323Soil Rock Calibration
Client Report No.
Address
Project Test Date
Report Date
Client ID
Description Sample Type
Notes/Remarks:
Photo not to scale Sample/s supplied by the client Page 4 REP37101
Laboratory No. 9926
P 18020062- DS
Mindijup Landfill 1/03/2018
8/03/2018
Sample 1
DIRECT SHEAR TEST REPORTTest Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol. 2
Bowman & Associates Pty Ltd
The results of calibrations and tests performed apply only to the specific instrument or sample at the time of test unless otherwise clearly stated.
Reference should be made to Trilab's “Standard Terms and Conditions of Business” for further details.Trilab Pty Ltd ABN 25 065 630 506
PO Box 2059 ROSSMOYNE WA 6148
Depth (m) Not Supplied
CLAYEY SAND - mottled red / grey Three individual soil specimens - Remoulded as
requested by the client (-4.75mm material
tested)
Authorised Signatory
B. Brash
Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations, and/or measurements included in this
document are traceable to Australian/National Standards.
Tested at Trilab Perth Laboratory
Authorised Signatory
C. Channon
ACCURATE QUALITY RESULTS FOR TOMORROW'S ENGINEERING
![Page 10: 13.3 APPENDIX C SOIL TEST RESULTS · CLAYEY SAND - mottled red / grey DIRECT SHEAR TEST REPORT Residual @ 8 mm Displacement Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol](https://reader030.vdocuments.mx/reader030/viewer/2022040907/5e7e45d4f112da00bd21f0dc/html5/thumbnails/10.jpg)
Brisbane
346A Bilsen Road,
Geebung
QLD 4034
Ph: +61 7 3265 5656
Perth
2 Kimmer Place,
Queens Park
WA 6107
Ph: +61 8 9258 8323Soil Rock Calibration
chrisc 1919
James
Client Report No.
Address
Project Test Date
Report Date
Client ID Depth (m)
17.00 31.00
1.40 1.70
NOTES/REMARKS: This is a computer generated plot so estimates may show some minor variations
from the results summarised.
Sample/s supplied by the client % Voids based on assumed SG of 2.67 Page 1 of 1 REP31302
Laboratory No. 9926
Maximum Dry Density (t/m3)
Trilab Pty Ltd ABN 25 065 630 506
Reference should be made to Trilab's “Standard Terms and Conditions of Business” for further details.
The results of calibrations and tests performed apply only to the specific instrument or sample at the time of test unless otherwise clearly stated.
0/19
22.4
Moisture Content (%) 19.9
1.56
Percentage of Oversize/Sieve Size (mm)
Optimum Moisture Content (%)
Sample 2
MOISTURE/DENSITY RELATIONSHIP TEST REPORTTest Method: AS 1289 5.1.1
Mindijup Landfill
P18020063-MDD
22/02/2018
21/02/2018
Not Supplied
Bowman & Associates Pty Ltd
PO Box 2059 ROSSMOYNE WA 6148
Authorised Signatory
A. Harrap
1.400
1.450
1.500
1.550
1.600
1.650
1.700
17.0 19.0 21.0 23.0 25.0 27.0 29.0 31.0
Dry
Den
sity
(t/
m3 )
Moisture Content (%)
Test Data MDD at OMC Cubic Spline Interpolation 0% Air Voids 2% Air Voids 4% Air Voids
Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations, and/or measurements included in
this document are traceable to Australian/National Standards.
Tested at Trilab Perth Laboratory.
Authorised Signatory
C. Channon
ACCURATE QUALITY RESULTS FOR TOMORROW'S ENGINEERING
![Page 11: 13.3 APPENDIX C SOIL TEST RESULTS · CLAYEY SAND - mottled red / grey DIRECT SHEAR TEST REPORT Residual @ 8 mm Displacement Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol](https://reader030.vdocuments.mx/reader030/viewer/2022040907/5e7e45d4f112da00bd21f0dc/html5/thumbnails/11.jpg)
Brisbane
10/104 Newmarket Rd,
Windsor
QLD 4030
Ph: +61 7 3357 5535
Perth
2 Kimmer Place,
Queens Park
WA 6107
Ph: +61 8 9258 8323Soil Rock Calibration
chrisc 1919
Client Report No.
Address
Project Test Date
Report Date
Client ID
Description Sample Type
Compaction Method AS1289.5.1.1 - Standard Compaction
Maximum Dry Density (t/m3) Hydraulic Gradient
Optimum Moisture Content (%) Surcharge (kPa)
Placement Moisture Content (%) Head Pressure Applied (kPa)
Moisture Ratio (%) Water Type
Placement Wet Density (t/m3) Percentage Material Retained/Sieve Size (mm)
Density Ratio (%) Sample Height and Diameter (mm)
Remarks: The above specimen was remoulded to a target of 98% of Standard Maximum Dry Density and at Optimum Moisture Content.
Sample/s supplied by client REP36301
PO Box 2059 ROSSMOYNE WA 6148
97.7
The results of calibrations and tests performed apply only to the specific instrument or sample at the time of test unless otherwise clearly stated.
Reference should be made to Trilab's “Standard Terms and Conditions of Business” for further details.
Depth (m) Not Supplied
0 / 19
Distilled
1.87
CLAY - mottled grey / brown
101.7
Trilab Pty Ltd ABN 25 065 630 506
Laboratory No. 9926
116.5 / 101.1
PERMEABILITY k(20) =
Page: 1 of 1
6.1E-10 (m/sec)
PERMEABILITY BY FALLING HEAD TEST REPORT
Test Method AS 1289 6.7.2, 5.1.1 , KH2 (Based on K H Head (1988) Manual of Laboratory Testing,10.7)
10.1
3.0
11.58
RESULTS OF TESTING
1.56
22.4
22.8
Mindijup Landfill
Remoulded Soil Specimen
23/02/2018
3/02/2018
P 18020063-FHPT
Sample 2
Bowman & Associates Pty Ltd
Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations, and/or measurements included in
this document are traceable to Australian/National Standards.
Tested at Trilab Perth Laboratory
1.000E-10
2.000E-10
3.000E-10
4.000E-10
5.000E-10
6.000E-10
7.000E-10
8.000E-10
9.000E-10
0 1000 2000 3000 4000 5000 6000 7000
k20
(m
/sec
)
Elapsed Time of Test (mins)
Permeability
Authorised Signatory
C. Channon
ACCURATE QUALITY RESULTS FOR TOMORROW'S ENGINEERING
![Page 12: 13.3 APPENDIX C SOIL TEST RESULTS · CLAYEY SAND - mottled red / grey DIRECT SHEAR TEST REPORT Residual @ 8 mm Displacement Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol](https://reader030.vdocuments.mx/reader030/viewer/2022040907/5e7e45d4f112da00bd21f0dc/html5/thumbnails/12.jpg)
Brisbane
346A Bilsen Road,
Geebung
QLD 4034
Ph: +61 7 3265 5656
Perth
2 Kimmer Place,
Queens Park
WA 6107
Ph: +61 8 9258 8323Soil Rock Calibration
chrisc 1919
James
Client Report No.
Address
Project Test Date
Report Date
Client ID Depth (m)
6.00 17.00
1.70 2.10
NOTES/REMARKS: This is a computer generated plot so estimates may show some minor variations
from the results summarised.
Sample/s supplied by the client % Voids based on assumed SG of 2.59 Page 1 of 1 REP31302
Laboratory No. 9926
Sample 3
MOISTURE/DENSITY RELATIONSHIP TEST REPORTTest Method: AS 1289 5.1.1
Mindijup Landfill
P18020064-MDD
7/03/2018
6/03/2018
Not Supplied
Bowman & Associates Pty Ltd
PO Box 2059 ROSSMOYNE WA 6148
Maximum Dry Density (t/m3)
Trilab Pty Ltd ABN 25 065 630 506
Reference should be made to Trilab's “Standard Terms and Conditions of Business” for further details.
The results of calibrations and tests performed apply only to the specific instrument or sample at the time of test unless otherwise clearly stated.
0/19
11.2
Moisture Content (%) 9.3
1.87
Percentage of Oversize/Sieve Size (mm)
Optimum Moisture Content (%)
Authorised Signatory
A. Harrap
1.700
1.750
1.800
1.850
1.900
1.950
2.000
2.050
2.100
6.0 8.0 10.0 12.0 14.0 16.0
Dry
Den
sity
(t/
m3 )
Moisture Content (%)
Test Data MDD at OMC Cubic Spline Interpolation 0% Air Voids 2% Air Voids 4% Air Voids
Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations, and/or measurements included in
this document are traceable to Australian/National Standards.
Tested at Trilab Perth Laboratory.
Authorised Signatory
C. Channon
ACCURATE QUALITY RESULTS FOR TOMORROW'S ENGINEERING
![Page 13: 13.3 APPENDIX C SOIL TEST RESULTS · CLAYEY SAND - mottled red / grey DIRECT SHEAR TEST REPORT Residual @ 8 mm Displacement Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol](https://reader030.vdocuments.mx/reader030/viewer/2022040907/5e7e45d4f112da00bd21f0dc/html5/thumbnails/13.jpg)
Brisbane
346A Bilsen Road,
Geebung
QLD 4034
Ph: +61 7 3265 5656
Perth
2 Kimmer Place,
Queens Park
WA 6107
Ph: +61 8 9258 8323Soil Rock Calibrationchrisc 1919
Client Report No.
Address
Project Test Date
Report Date
Client ID
Description Sample Type
Failure Criteria
Notes/Remarks: Please review the results if the Cohesion is above 2 kPa when plotted with a line of best fit
Note: Area correction based on square sample equation.
Graph not to scale Sample/s supplied by the client Page 1 REP37101
Laboratory No. 9926
DIRECT SHEAR TEST REPORT
Residual @ 7 mm Displacement
Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol. 2
16/03/2018
7/03/2018
Not SuppliedDepth (m)
Mindijup Landfill
Sample 4
P 18020065- DSBowman & Associates Pty Ltd
PO Box 2059 ROSSMOYNE WA 6148
Trilab Pty Ltd ABN 25 065 630 506
Three individual soil specimens - Remoulded as
requested by the client (-4.75mmmaterial tested)SAND- white
The results of calibrations and tests performed apply only to the specific instrument or sample at the time of test unless otherwise clearly stated.
Reference should be made to Trilab's “Standard Terms and Conditions of Business” for further details.
Authorised Signatory
B. Brash
25 kPa
50.1 kPa
100 kPa
0
10
20
30
40
50
60
70
80
90
100
0 2 4 6 8 10 12
Sh
ear
Str
es
s (
kP
a)
Relative Displacement (mm)
Shear Stress/Displacement Plot
25 kPa
50.1 kPa
100 kPa
-0.10
0.10.20.30.40.50.6
0 2 4 6 8 10 12
Vert
ical D
isp
lacem
en
t (m
m)
Relative Displacement (mm)
Vertical Displacement/Relative Displacement Plot
Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations, and/or measurements included in this
document are traceable to Australian/National Standards.
Tested at Trilab Perth Laboratory
Authorised Signatory
C. Channon
ACCURATE QUALITY RESULTS FOR TOMORROW'S ENGINEERING
![Page 14: 13.3 APPENDIX C SOIL TEST RESULTS · CLAYEY SAND - mottled red / grey DIRECT SHEAR TEST REPORT Residual @ 8 mm Displacement Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol](https://reader030.vdocuments.mx/reader030/viewer/2022040907/5e7e45d4f112da00bd21f0dc/html5/thumbnails/14.jpg)
Brisbane
346A Bilsen Road,
Geebung
QLD 4034
Ph: +61 7 3265 5656
Perth
2 Kimmer Place,
Queens Park
WA 6107
Ph: +61 8 9258 8323Soil Rock Calibration
chrisc 1919
James
Client Report No.
Address
Project Test Date
Report Date
Client ID Depth (m)
10.00 20.00
1.50 1.90
NOTES/REMARKS: This is a computer generated plot so estimates may show some minor variations
from the results summarised.
Sample/s supplied by the client % Voids based on assumed SG of 2.48 Page 1 of 1 REP31302
Laboratory No. 9926
Maximum Dry Density (t/m3)
Trilab Pty Ltd ABN 25 065 630 506
Reference should be made to Trilab's “Standard Terms and Conditions of Business” for further details.
The results of calibrations and tests performed apply only to the specific instrument or sample at the time of test unless otherwise clearly stated.
0/19
14.9
Moisture Content (%) 2.3
1.69
Percentage of Oversize/Sieve Size (mm)
Optimum Moisture Content (%)
Sample 4
MOISTURE/DENSITY RELATIONSHIP TEST REPORTTest Method: AS 1289 5.1.1
Mindijup Landfill
P18020065-MDD
7/03/2018
6/03/2018
Not Supplied
Bowman & Associates Pty Ltd
PO Box 2059 ROSSMOYNE WA 6148
Authorised Signatory
A. Harrap
1.500
1.550
1.600
1.650
1.700
1.750
1.800
1.850
1.900
10.0 11.0 12.0 13.0 14.0 15.0 16.0 17.0 18.0 19.0 20.0
Dry
Den
sity
(t/
m3 )
Moisture Content (%)
Test Data MDD at OMC Cubic Spline Interpolation 0% Air Voids 2% Air Voids 4% Air Voids
Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations, and/or measurements included in
this document are traceable to Australian/National Standards.
Tested at Trilab Perth Laboratory.
Authorised Signatory
C. Channon
ACCURATE QUALITY RESULTS FOR TOMORROW'S ENGINEERING
![Page 15: 13.3 APPENDIX C SOIL TEST RESULTS · CLAYEY SAND - mottled red / grey DIRECT SHEAR TEST REPORT Residual @ 8 mm Displacement Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol](https://reader030.vdocuments.mx/reader030/viewer/2022040907/5e7e45d4f112da00bd21f0dc/html5/thumbnails/15.jpg)
Brisbane
346A Bilsen Road,
Geebung
QLD 4034
Ph: +61 7 3265 5656
Perth
2 Kimmer Place,
Queens Park
WA 6107
Ph: +61 8 9258 8323Soil Rock Calibration
Client Report No.
Address
Project Test Date
Report Date
Client ID
Description Sample Type
Failure Criteria
40.1 2.9 R2
Specimen Condition Shear Stress (kPa)
Specimen Dimensions (mm)
Rate of Strain (mm/min)
Initial Moisture Content (%)
Initial Wet Density(t/m3)
Notes/Remarks: Please review the results if the Cohesion is above 2 kPa when plotted with a line of best fit
Note: Area correction based on square sample equation.
Graph not to scale Sample/s supplied by the client Page 2 REP37101
Laboratory No. 9926
PO Box 2059 ROSSMOYNE WA 6148
0.991
14.5
100*100
The results of calibrations and tests performed apply only to the specific instrument or sample at the time of test unless otherwise clearly stated.
Reference should be made to Trilab's “Standard Terms and Conditions of Business” for further details.Trilab Pty Ltd ABN 25 065 630 506
Stage 3
Stage 2
Shear Angle (o)
Bowman & Associates Pty Ltd
20.8
DIRECT SHEAR TEST REPORT
Residual @ 7 mm Displacement
Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol. 2
Mindijup Landfill
25.0
Sample 4 Depth (m) Not Supplied
SAND- white Three individual soil specimens - Remoulded as
requested by the client (-4.75mmmaterial tested)
Stage 1
7/03/2018
16/03/2018
Cohesion (kPa)
P 18020065- DS
0.008
1.90
Inundated Normal Stress (kPa)
85.5
49.9
100.0
50.1
Authorised Signatory
B. Brash
0
20
40
60
80
100
0 20 40 60 80 100 120
Sh
ea
r S
tre
ss
(k
Pa
)
Normal Stress (kPa)
Residual - Normal Stress vs Shear Stress
Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations, and/or measurements included in this
document are traceable to Australian/National Standards.
Tested at Trilab Perth Laboratory
Authorised Signatory
C. Channon
ACCURATE QUALITY RESULTS FOR TOMORROW'S ENGINEERING
![Page 16: 13.3 APPENDIX C SOIL TEST RESULTS · CLAYEY SAND - mottled red / grey DIRECT SHEAR TEST REPORT Residual @ 8 mm Displacement Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol](https://reader030.vdocuments.mx/reader030/viewer/2022040907/5e7e45d4f112da00bd21f0dc/html5/thumbnails/16.jpg)
Brisbane
346A Bilsen Road,
Geebung
QLD 4034
Ph: +61 7 3265 5656
Perth
2 Kimmer Place,
Queens Park
WA 6107
Ph: +61 8 9258 8323Soil Rock Calibration
Client Report No.
Address
Project Test Date
Report Date
Client ID
Description Sample Type
Failure Criteria
40.6 6.2 R2
Specimen Condition Shear Stress (kPa)
Specimen Dimensions (mm)
Rate of Strain (mm/min)
Initial Moisture Content (%)
Initial Wet Density(t/m3)
Notes/Remarks: Please review the results if the Cohesion is above 2 kPa when plotted with a line of best fit
Note: Area correction based on square sample equation.
Graph not to scale Sample/s supplied by the client Page 3 REP37101
Laboratory No. 9926
Inundated
Peak
PO Box 2059 ROSSMOYNE WA 6148
7/03/2018
16/03/2018
Sample 4 Depth (m) Not Supplied
The results of calibrations and tests performed apply only to the specific instrument or sample at the time of test unless otherwise clearly stated.
Reference should be made to Trilab's “Standard Terms and Conditions of Business” for further details.Trilab Pty Ltd ABN 25 065 630 506
52.7
25.3
100.0
50.1
25.0
90.6
1.90
100*100
Stage 3
Stage 2
Stage 1
Cohesion (kPa)
Normal Stress (kPa)
0.008
14.5
SAND- white Three individual soil specimens - Remoulded as
requested by the client (-4.75mmmaterial tested)
Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol. 2
Shear Angle (o) 0.995
Bowman & Associates Pty Ltd
DIRECT SHEAR TEST REPORT
P 18020065- DS
Mindijup Landfill
Authorised Signatory
B. Brash
0
20
40
60
80
100
0 20 40 60 80 100 120
Sh
ea
r S
tre
ss
(k
Pa
)
Normal Stress (kPa)
Peak - Normal Stress vs Shear Stress
Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations, and/or measurements included in this
document are traceable to Australian/National Standards.
Tested at Trilab Perth Laboratory
Authorised Signatory
C. Channon
ACCURATE QUALITY RESULTS FOR TOMORROW'S ENGINEERING
![Page 17: 13.3 APPENDIX C SOIL TEST RESULTS · CLAYEY SAND - mottled red / grey DIRECT SHEAR TEST REPORT Residual @ 8 mm Displacement Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol](https://reader030.vdocuments.mx/reader030/viewer/2022040907/5e7e45d4f112da00bd21f0dc/html5/thumbnails/17.jpg)
Brisbane
346A Bilsen Road,
Geebung
QLD 4034
Ph: +61 7 3265 5656
Perth
2 Kimmer Place,
Queens Park
WA 6107
Ph: +61 8 9258 8323Soil Rock Calibration
Client Report No.
Address
Project Test Date
Report Date
Client ID
Description Sample Type
Notes/Remarks:
Photo not to scale Sample/s supplied by the client Page 4 REP37101
Laboratory No. 9926
PO Box 2059 ROSSMOYNE WA 6148
Depth (m) Not Supplied
SAND- white Three individual soil specimens - Remoulded as
requested by the client (-4.75mmmaterial tested)
The results of calibrations and tests performed apply only to the specific instrument or sample at the time of test unless otherwise clearly stated.
Reference should be made to Trilab's “Standard Terms and Conditions of Business” for further details.Trilab Pty Ltd ABN 25 065 630 506
DIRECT SHEAR TEST REPORTTest Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol. 2
Bowman & Associates Pty Ltd
Mindijup Landfill 7/03/2018
16/03/2018
Sample 4
P 18020065- DS
Authorised Signatory
B. Brash
Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations, and/or measurements included in this
document are traceable to Australian/National Standards.
Tested at Trilab Perth Laboratory
Authorised Signatory
C. Channon
ACCURATE QUALITY RESULTS FOR TOMORROW'S ENGINEERING
![Page 18: 13.3 APPENDIX C SOIL TEST RESULTS · CLAYEY SAND - mottled red / grey DIRECT SHEAR TEST REPORT Residual @ 8 mm Displacement Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol](https://reader030.vdocuments.mx/reader030/viewer/2022040907/5e7e45d4f112da00bd21f0dc/html5/thumbnails/18.jpg)
Vancouver Waste Disposal Facility - Application Licence Amendment
Prepared by Bowman & Associates Pty Ltd Page 73