Page 1: 13.3 APPENDIX C SOIL TEST RESULTS · CLAYEY SAND - mottled red / grey DIRECT SHEAR TEST REPORT Residual @ 8 mm Displacement Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol

Vancouver Waste Disposal Facility - Application Licence Amendment

Prepared by Bowman & Associates Pty Ltd Page 56

13.3 APPENDIX C – SOIL TEST RESULTS

Page 2: 13.3 APPENDIX C SOIL TEST RESULTS · CLAYEY SAND - mottled red / grey DIRECT SHEAR TEST REPORT Residual @ 8 mm Displacement Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol

Brisbane

346A Bilsen Road,

Geebung

QLD 4034

Ph: +61 7 3265 5656

Perth

2 Kimmer Place,

Queens Park

WA 6107

Ph: +61 8 9258 8323Soil Rock Calibration

chrisc 1919

James

Client Report No.

Address PO Box 2059 ROSSMOYNE WA 6148

Project Test Date

Report Date

18020062 18020063 18020064 18020065

Sample 1 Sample 2 Sample 3 Sample 4

Not Supplied Not Supplied Not Supplied Not Supplied

40 53 Not Obtainable Not Obtainable

19 22 Not Obtainable Not Obtainable

Plasticity Index (%) 21 31 Non Plastic Non Plastic

Linear Shrinkage (%) 9.5 * 13.0 * Not Obtainable Not Obtainable

Moisture Content (%) 12.1 19.9 9.3 2.3

Plasticity Index (%)

Linear Shrinkage (%)

Moisture Content (%)

NOTES/REMARKS: The samples were tested oven dried, dry sieved and in a 125-250mm mould.

Sample/s supplied by the client * Cracking occurred + Curling occurred Page 1 of 1 REP30101

Laboratory No. 9926

Depth (m)

Trilab Pty Ltd ABN 25 065 630 506

Reference should be made to Trilab's “Standard Terms and Conditions of Business” for further details.

The results of calibrations and tests performed apply only to the specific instrument or sample at the time of test unless otherwise clearly stated.

Liquid Limit (%)

Plastic Limit (%)

ATTERBERG LIMITS TEST REPORTTest Method: AS 1289 2.1.1, 3.1.1, 3.1.2, 3.2.1, 3.3.1, 3.4.1

Mindijup Landfill

P 18020062-AL

23/02/2018

19/02/2018

Bowman & Associates Pty Ltd

Sample No.

Client ID

Depth (m)

Client ID

Sample No.

Plastic Limit (%)

Liquid Limit (%)

Authorised Signatory

A. Harrap

Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations, and/or measurements included in

this document are traceable to Australian/National Standards.

Tested at Trilab Perth Laboratory.

Authorised Signatory

C. Channon

ACCURATE QUALITY RESULTS FOR TOMORROW'S ENGINEERING

Page 3: 13.3 APPENDIX C SOIL TEST RESULTS · CLAYEY SAND - mottled red / grey DIRECT SHEAR TEST REPORT Residual @ 8 mm Displacement Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol

Brisbane

346A Bilsen Road,

Geebung

QLD 4034

Ph: +61 7 3265 5656

Perth

2 Kimmer Place,

Queens Park

WA 6107

Ph: +61 8 9258 8323Soil Rock Calibration

chrisc 1919

James

Client Report No.

Address

Project Test Date

Report Date

Sample No. 18020062 18020063 18020064 18020065

Client ID Sample 1 Sample 2 Sample 3 Sample 4

Depth (m) Not Supplied Not Supplied Not Supplied Not Supplied

Moisture (%) 12.1 19.9 9.3 2.3

AS SIEVE SIZE

(mm)

150

75

53

37.5 100

26.5 98

19 97

9.5 97

4.75 97

2.36 97 100 100

1.18 97 99 98 100

0.600 94 99 92 90

0.425 67 96 70 78

0.300 42 94 35 69

0.150 30 83 20 37

0.075 26 68 13 9

NOTES/REMARKS:

Sample/s supplied by the client Page 1 of 1 REP31102

Laboratory No. 9926

PARTICLE SIZE DISTRIBUTION TEST REPORTTest Method: AS 1289 3.6.1, 2.1.1

Mindijup Landfill

P18020062-G

22/02/2018

19/02/2018

Bowman & Associates Pty Ltd

PO Box 2059 ROSSMOYNE WA 6148

PERCENT PASSING

Trilab Pty Ltd ABN 25 065 630 506

Reference should be made to Trilab's “Standard Terms and Conditions of Business” for further details.

The results of calibrations and tests performed apply only to the specific instrument or sample at the time of test unless otherwise clearly stated.

Authorised Signatory

A. Harrap

Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations, and/or measurements included in

this document are traceable to Australian/National Standards.

Tested at Trilab Perth Laboratory.

Authorised Signatory

C. Channon

ACCURATE QUALITY RESULTS FOR TOMORROW'S ENGINEERING

Page 4: 13.3 APPENDIX C SOIL TEST RESULTS · CLAYEY SAND - mottled red / grey DIRECT SHEAR TEST REPORT Residual @ 8 mm Displacement Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol

Brisbane

346A Bilsen Road,

Geebung

QLD 4034

Ph: +61 7 3265 5656

Perth

2 Kimmer Place,

Queens Park

WA 6107

Ph: +61 8 9258 8323Soil Rock Calibration

chrisc 1919

James

Client Report No.

Address

Project Test Date

Report Date

Client ID Depth (m)

6.00 17.00

1.60 2.00

NOTES/REMARKS: This is a computer generated plot so estimates may show some minor variations

from the results summarised.

Sample/s supplied by the client % Voids based on assumed SG of 2.48 Page 1 of 1 REP31302

Laboratory No. 9926

Sample 1

MOISTURE/DENSITY RELATIONSHIP TEST REPORTTest Method: AS 1289 5.1.1

Mindijup Landfill

P18020062-MDD

22/02/2018

21/02/2018

Not Supplied

Bowman & Associates Pty Ltd

PO Box 2059 ROSSMOYNE WA 6148

Maximum Dry Density (t/m3)

Trilab Pty Ltd ABN 25 065 630 506

Reference should be made to Trilab's “Standard Terms and Conditions of Business” for further details.

The results of calibrations and tests performed apply only to the specific instrument or sample at the time of test unless otherwise clearly stated.

3/19

12.1

Moisture Content (%) 12.1

1.79

Percentage of Oversize/Sieve Size (mm)

Optimum Moisture Content (%)

Authorised Signatory

A. Harrap

1.600

1.650

1.700

1.750

1.800

1.850

1.900

1.950

2.000

6.0 8.0 10.0 12.0 14.0 16.0

Dry

Den

sity

(t/

m3 )

Moisture Content (%)

Test Data MDD at OMC Cubic Spline Interpolation 0% Air Voids 2% Air Voids 4% Air Voids

Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations, and/or measurements included in

this document are traceable to Australian/National Standards.

Tested at Trilab Perth Laboratory.

Authorised Signatory

C. Channon

ACCURATE QUALITY RESULTS FOR TOMORROW'S ENGINEERING

Page 5: 13.3 APPENDIX C SOIL TEST RESULTS · CLAYEY SAND - mottled red / grey DIRECT SHEAR TEST REPORT Residual @ 8 mm Displacement Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol

Brisbane

346A Bilsen Road,

Geebung

QLD 4034

Ph: +61 7 3265 5656

Perth

2 Kimmer Place,

Queens Park

WA 6107

Ph: +61 8 9258 8323Soil Rock Calibrationchrisc 1919

Client Report No.

Address

Project Test Date

Report Date

Client ID

Description Sample Type

Failure Criteria

Notes/Remarks: Please review the results if the Cohesion is above 2 kPa when plotted with a line of best fit

Note: Area correction based on square sample equation.

Graph not to scale Sample/s supplied by the client Page 1 REP37101

Laboratory No. 9926 The results of calibrations and tests performed apply only to the specific instrument or sample at the time of test unless otherwise clearly stated.

Reference should be made to Trilab's “Standard Terms and Conditions of Business” for further details.Trilab Pty Ltd ABN 25 065 630 506

Three individual soil specimens - Remoulded as

requested by the client (-4.75mm material

tested)

CLAYEY SAND - mottled red / grey

DIRECT SHEAR TEST REPORT

Residual @ 8 mm Displacement

Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol. 2

8/03/2018

1/03/2018

Not SuppliedDepth (m)

Mindijup Landfill

Sample 1

P 18020062- DSBowman & Associates Pty Ltd

PO Box 2059 ROSSMOYNE WA 6148

Authorised Signatory

B. Brash

25 kPa

50.1 kPa

100.1 kPa

0

10

20

30

40

50

60

70

80

0 2 4 6 8 10 12

Sh

ear

Str

es

s (

kP

a)

Relative Displacement (mm)

Shear Stress/Displacement Plot

25 kPa

50.1 kPa 100.1 kPa

-0.1

0

0.1

0.2

0.3

0.4

0.5

0 2 4 6 8 10 12

Vert

ical D

isp

lacem

en

t (m

m)

Relative Displacement (mm)

Vertical Displacement/Relative Displacement Plot

Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations, and/or measurements included in this

document are traceable to Australian/National Standards.

Tested at Trilab Perth Laboratory

Authorised Signatory

C. Channon

ACCURATE QUALITY RESULTS FOR TOMORROW'S ENGINEERING

Page 6: 13.3 APPENDIX C SOIL TEST RESULTS · CLAYEY SAND - mottled red / grey DIRECT SHEAR TEST REPORT Residual @ 8 mm Displacement Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol

Brisbane

346A Bilsen Road,

Geebung

QLD 4034

Ph: +61 7 3265 5656

Perth

2 Kimmer Place,

Queens Park

WA 6107

Ph: +61 8 9258 8323Soil Rock Calibration

Client Report No.

Address

Project Test Date

Report Date

Client ID

Description Sample Type

Failure Criteria

33.1 5.5 R2

Specimen Condition Shear Stress (kPa)

Specimen Dimensions (mm)

Rate of Strain (mm/min)

Initial Moisture Content (%)

Initial Wet Density(t/m3)

Notes/Remarks: Please review the results if the Cohesion is above 2 kPa when plotted with a line of best fit

Note: Area correction based on square sample equation.

Graph not to scale Sample/s supplied by the client Page 2 REP37101

Laboratory No. 9926

0.008

0.00

Inundated Normal Stress (kPa)

70.7

38.1

100.1

50.1

21.8

DIRECT SHEAR TEST REPORT

Residual @ 8 mm Displacement

Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol. 2

Mindijup Landfill

25.0

Sample 1 Depth (m) Not Supplied

CLAYEY SAND - mottled red / grey Three individual soil specimens - Remoulded as

requested by the client (-4.75mm material

tested)

Stage 1

1/03/2018

8/03/2018

Cohesion (kPa)

P 18020062- DS

1.000

12.1

100*100

The results of calibrations and tests performed apply only to the specific instrument or sample at the time of test unless otherwise clearly stated.

Reference should be made to Trilab's “Standard Terms and Conditions of Business” for further details.Trilab Pty Ltd ABN 25 065 630 506

Stage 3

Stage 2

Shear Angle (o)

PO Box 2059 ROSSMOYNE WA 6148

Bowman & Associates Pty Ltd

Authorised Signatory

B. Brash

0

20

40

60

80

100

0 20 40 60 80 100 120

Sh

ea

r S

tre

ss

(k

Pa

)

Normal Stress (kPa)

Residual - Normal Stress vs Shear Stress

Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations, and/or measurements included in this

document are traceable to Australian/National Standards.

Tested at Trilab Perth Laboratory

Authorised Signatory

C. Channon

ACCURATE QUALITY RESULTS FOR TOMORROW'S ENGINEERING

Page 7: 13.3 APPENDIX C SOIL TEST RESULTS · CLAYEY SAND - mottled red / grey DIRECT SHEAR TEST REPORT Residual @ 8 mm Displacement Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol

Brisbane

346A Bilsen Road,

Geebung

QLD 4034

Ph: +61 7 3265 5656

Perth

2 Kimmer Place,

Queens Park

WA 6107

Ph: +61 8 9258 8323Soil Rock Calibration

Client Report No.

Address

Project Test Date

Report Date

Client ID

Description Sample Type

Failure Criteria

32.5 8.7 R2

Specimen Condition Shear Stress (kPa)

Specimen Dimensions (mm)

Rate of Strain (mm/min)

Initial Moisture Content (%)

Initial Wet Density(t/m3)

Notes/Remarks: Please review the results if the Cohesion is above 2 kPa when plotted with a line of best fit

Note: Area correction based on square sample equation.

Graph not to scale Sample/s supplied by the client Page 3 REP37101

Laboratory No. 9926

Mindijup Landfill

DIRECT SHEAR TEST REPORT

P 18020062- DS

Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol. 2

Shear Angle (o) 0.999

Bowman & Associates Pty Ltd

Stage 3

Stage 2

Stage 1

Cohesion (kPa)

Normal Stress (kPa)

0.008

12.1

The results of calibrations and tests performed apply only to the specific instrument or sample at the time of test unless otherwise clearly stated.

Reference should be made to Trilab's “Standard Terms and Conditions of Business” for further details.Trilab Pty Ltd ABN 25 065 630 506

39.7

25.3

100.1

50.1

25.0

72.9

0.00

100*100

Inundated

Peak

PO Box 2059 ROSSMOYNE WA 6148

1/03/2018

8/03/2018

Sample 1 Depth (m) Not Supplied

CLAYEY SAND - mottled red / grey Three individual soil specimens - Remoulded as

requested by the client (-4.75mm material

tested)

Authorised Signatory

B. Brash

0

20

40

60

80

100

0 20 40 60 80 100 120

Sh

ea

r S

tre

ss

(k

Pa

)

Normal Stress (kPa)

Peak - Normal Stress vs Shear Stress

Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations, and/or measurements included in this

document are traceable to Australian/National Standards.

Tested at Trilab Perth Laboratory

Authorised Signatory

C. Channon

ACCURATE QUALITY RESULTS FOR TOMORROW'S ENGINEERING

Page 8: 13.3 APPENDIX C SOIL TEST RESULTS · CLAYEY SAND - mottled red / grey DIRECT SHEAR TEST REPORT Residual @ 8 mm Displacement Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol

Brisbane

10/104 Newmarket Rd,

Windsor

QLD 4030

Ph: +61 7 3357 5535

Perth

2 Kimmer Place,

Queens Park

WA 6107

Ph: +61 8 9258 8323Soil Rock Calibration

chrisc 1919

Client Report No.

Address

Project Test Date

Report Date

Client ID

Description Sample Type

Compaction Method AS1289.5.1.1 - Standard Compaction

Maximum Dry Density (t/m3) Hydraulic Gradient

Optimum Moisture Content (%) Surcharge (kPa)

Placement Moisture Content (%) Head Pressure Applied (kPa)

Moisture Ratio (%) Water Type

Placement Wet Density (t/m3) Percentage Material Retained/Sieve Size (mm)

Density Ratio (%) Sample Height and Diameter (mm)

Remarks: The above specimen was remoulded to a target of 98% of Standard Maximum Dry Density and at Optimum Moisture Content.

Sample/s supplied by client REP36301

PO Box 2059 ROSSMOYNE WA 6148

98.1

The results of calibrations and tests performed apply only to the specific instrument or sample at the time of test unless otherwise clearly stated.

Reference should be made to Trilab's “Standard Terms and Conditions of Business” for further details.

Depth (m) Not Supplied

3 / 19

Distilled

1.97

CLAY SANDY- mottled red / grey

99.7

Trilab Pty Ltd ABN 25 065 630 506

Laboratory No. 9926

116.5 / 101.1

PERMEABILITY k(20) =

Page: 1 of 1

4.5E-10 (m/sec)

PERMEABILITY BY FALLING HEAD TEST REPORT

Test Method AS 1289 6.7.2, 5.1.1 , KH2 (Based on K H Head (1988) Manual of Laboratory Testing,10.7)

10.1

3.0

11.58

RESULTS OF TESTING

1.79

12.1

12.1

Mindijup Landfill

Remoulded Soil Specimen

23/02/2018

2/03/2018

P 18020062-FHPT

Sample 1

Bowman & Associates Pty Ltd

Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations, and/or measurements included in

this document are traceable to Australian/National Standards.

Tested at Trilab Perth Laboratory

1.000E-10

2.000E-10

3.000E-10

4.000E-10

5.000E-10

6.000E-10

7.000E-10

8.000E-10

9.000E-10

0 1000 2000 3000 4000 5000 6000 7000

k20

(m

/sec

)

Elapsed Time of Test (mins)

Permeability

Authorised Signatory

C. Channon

ACCURATE QUALITY RESULTS FOR TOMORROW'S ENGINEERING

Page 9: 13.3 APPENDIX C SOIL TEST RESULTS · CLAYEY SAND - mottled red / grey DIRECT SHEAR TEST REPORT Residual @ 8 mm Displacement Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol

Brisbane

346A Bilsen Road,

Geebung

QLD 4034

Ph: +61 7 3265 5656

Perth

2 Kimmer Place,

Queens Park

WA 6107

Ph: +61 8 9258 8323Soil Rock Calibration

Client Report No.

Address

Project Test Date

Report Date

Client ID

Description Sample Type

Notes/Remarks:

Photo not to scale Sample/s supplied by the client Page 4 REP37101

Laboratory No. 9926

P 18020062- DS

Mindijup Landfill 1/03/2018

8/03/2018

Sample 1

DIRECT SHEAR TEST REPORTTest Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol. 2

Bowman & Associates Pty Ltd

The results of calibrations and tests performed apply only to the specific instrument or sample at the time of test unless otherwise clearly stated.

Reference should be made to Trilab's “Standard Terms and Conditions of Business” for further details.Trilab Pty Ltd ABN 25 065 630 506

PO Box 2059 ROSSMOYNE WA 6148

Depth (m) Not Supplied

CLAYEY SAND - mottled red / grey Three individual soil specimens - Remoulded as

requested by the client (-4.75mm material

tested)

Authorised Signatory

B. Brash

Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations, and/or measurements included in this

document are traceable to Australian/National Standards.

Tested at Trilab Perth Laboratory

Authorised Signatory

C. Channon

ACCURATE QUALITY RESULTS FOR TOMORROW'S ENGINEERING

Page 10: 13.3 APPENDIX C SOIL TEST RESULTS · CLAYEY SAND - mottled red / grey DIRECT SHEAR TEST REPORT Residual @ 8 mm Displacement Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol

Brisbane

346A Bilsen Road,

Geebung

QLD 4034

Ph: +61 7 3265 5656

Perth

2 Kimmer Place,

Queens Park

WA 6107

Ph: +61 8 9258 8323Soil Rock Calibration

chrisc 1919

James

Client Report No.

Address

Project Test Date

Report Date

Client ID Depth (m)

17.00 31.00

1.40 1.70

NOTES/REMARKS: This is a computer generated plot so estimates may show some minor variations

from the results summarised.

Sample/s supplied by the client % Voids based on assumed SG of 2.67 Page 1 of 1 REP31302

Laboratory No. 9926

Maximum Dry Density (t/m3)

Trilab Pty Ltd ABN 25 065 630 506

Reference should be made to Trilab's “Standard Terms and Conditions of Business” for further details.

The results of calibrations and tests performed apply only to the specific instrument or sample at the time of test unless otherwise clearly stated.

0/19

22.4

Moisture Content (%) 19.9

1.56

Percentage of Oversize/Sieve Size (mm)

Optimum Moisture Content (%)

Sample 2

MOISTURE/DENSITY RELATIONSHIP TEST REPORTTest Method: AS 1289 5.1.1

Mindijup Landfill

P18020063-MDD

22/02/2018

21/02/2018

Not Supplied

Bowman & Associates Pty Ltd

PO Box 2059 ROSSMOYNE WA 6148

Authorised Signatory

A. Harrap

1.400

1.450

1.500

1.550

1.600

1.650

1.700

17.0 19.0 21.0 23.0 25.0 27.0 29.0 31.0

Dry

Den

sity

(t/

m3 )

Moisture Content (%)

Test Data MDD at OMC Cubic Spline Interpolation 0% Air Voids 2% Air Voids 4% Air Voids

Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations, and/or measurements included in

this document are traceable to Australian/National Standards.

Tested at Trilab Perth Laboratory.

Authorised Signatory

C. Channon

ACCURATE QUALITY RESULTS FOR TOMORROW'S ENGINEERING

Page 11: 13.3 APPENDIX C SOIL TEST RESULTS · CLAYEY SAND - mottled red / grey DIRECT SHEAR TEST REPORT Residual @ 8 mm Displacement Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol

Brisbane

10/104 Newmarket Rd,

Windsor

QLD 4030

Ph: +61 7 3357 5535

Perth

2 Kimmer Place,

Queens Park

WA 6107

Ph: +61 8 9258 8323Soil Rock Calibration

chrisc 1919

Client Report No.

Address

Project Test Date

Report Date

Client ID

Description Sample Type

Compaction Method AS1289.5.1.1 - Standard Compaction

Maximum Dry Density (t/m3) Hydraulic Gradient

Optimum Moisture Content (%) Surcharge (kPa)

Placement Moisture Content (%) Head Pressure Applied (kPa)

Moisture Ratio (%) Water Type

Placement Wet Density (t/m3) Percentage Material Retained/Sieve Size (mm)

Density Ratio (%) Sample Height and Diameter (mm)

Remarks: The above specimen was remoulded to a target of 98% of Standard Maximum Dry Density and at Optimum Moisture Content.

Sample/s supplied by client REP36301

PO Box 2059 ROSSMOYNE WA 6148

97.7

The results of calibrations and tests performed apply only to the specific instrument or sample at the time of test unless otherwise clearly stated.

Reference should be made to Trilab's “Standard Terms and Conditions of Business” for further details.

Depth (m) Not Supplied

0 / 19

Distilled

1.87

CLAY - mottled grey / brown

101.7

Trilab Pty Ltd ABN 25 065 630 506

Laboratory No. 9926

116.5 / 101.1

PERMEABILITY k(20) =

Page: 1 of 1

6.1E-10 (m/sec)

PERMEABILITY BY FALLING HEAD TEST REPORT

Test Method AS 1289 6.7.2, 5.1.1 , KH2 (Based on K H Head (1988) Manual of Laboratory Testing,10.7)

10.1

3.0

11.58

RESULTS OF TESTING

1.56

22.4

22.8

Mindijup Landfill

Remoulded Soil Specimen

23/02/2018

3/02/2018

P 18020063-FHPT

Sample 2

Bowman & Associates Pty Ltd

Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations, and/or measurements included in

this document are traceable to Australian/National Standards.

Tested at Trilab Perth Laboratory

1.000E-10

2.000E-10

3.000E-10

4.000E-10

5.000E-10

6.000E-10

7.000E-10

8.000E-10

9.000E-10

0 1000 2000 3000 4000 5000 6000 7000

k20

(m

/sec

)

Elapsed Time of Test (mins)

Permeability

Authorised Signatory

C. Channon

ACCURATE QUALITY RESULTS FOR TOMORROW'S ENGINEERING

Page 12: 13.3 APPENDIX C SOIL TEST RESULTS · CLAYEY SAND - mottled red / grey DIRECT SHEAR TEST REPORT Residual @ 8 mm Displacement Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol

Brisbane

346A Bilsen Road,

Geebung

QLD 4034

Ph: +61 7 3265 5656

Perth

2 Kimmer Place,

Queens Park

WA 6107

Ph: +61 8 9258 8323Soil Rock Calibration

chrisc 1919

James

Client Report No.

Address

Project Test Date

Report Date

Client ID Depth (m)

6.00 17.00

1.70 2.10

NOTES/REMARKS: This is a computer generated plot so estimates may show some minor variations

from the results summarised.

Sample/s supplied by the client % Voids based on assumed SG of 2.59 Page 1 of 1 REP31302

Laboratory No. 9926

Sample 3

MOISTURE/DENSITY RELATIONSHIP TEST REPORTTest Method: AS 1289 5.1.1

Mindijup Landfill

P18020064-MDD

7/03/2018

6/03/2018

Not Supplied

Bowman & Associates Pty Ltd

PO Box 2059 ROSSMOYNE WA 6148

Maximum Dry Density (t/m3)

Trilab Pty Ltd ABN 25 065 630 506

Reference should be made to Trilab's “Standard Terms and Conditions of Business” for further details.

The results of calibrations and tests performed apply only to the specific instrument or sample at the time of test unless otherwise clearly stated.

0/19

11.2

Moisture Content (%) 9.3

1.87

Percentage of Oversize/Sieve Size (mm)

Optimum Moisture Content (%)

Authorised Signatory

A. Harrap

1.700

1.750

1.800

1.850

1.900

1.950

2.000

2.050

2.100

6.0 8.0 10.0 12.0 14.0 16.0

Dry

Den

sity

(t/

m3 )

Moisture Content (%)

Test Data MDD at OMC Cubic Spline Interpolation 0% Air Voids 2% Air Voids 4% Air Voids

Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations, and/or measurements included in

this document are traceable to Australian/National Standards.

Tested at Trilab Perth Laboratory.

Authorised Signatory

C. Channon

ACCURATE QUALITY RESULTS FOR TOMORROW'S ENGINEERING

Page 13: 13.3 APPENDIX C SOIL TEST RESULTS · CLAYEY SAND - mottled red / grey DIRECT SHEAR TEST REPORT Residual @ 8 mm Displacement Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol

Brisbane

346A Bilsen Road,

Geebung

QLD 4034

Ph: +61 7 3265 5656

Perth

2 Kimmer Place,

Queens Park

WA 6107

Ph: +61 8 9258 8323Soil Rock Calibrationchrisc 1919

Client Report No.

Address

Project Test Date

Report Date

Client ID

Description Sample Type

Failure Criteria

Notes/Remarks: Please review the results if the Cohesion is above 2 kPa when plotted with a line of best fit

Note: Area correction based on square sample equation.

Graph not to scale Sample/s supplied by the client Page 1 REP37101

Laboratory No. 9926

DIRECT SHEAR TEST REPORT

Residual @ 7 mm Displacement

Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol. 2

16/03/2018

7/03/2018

Not SuppliedDepth (m)

Mindijup Landfill

Sample 4

P 18020065- DSBowman & Associates Pty Ltd

PO Box 2059 ROSSMOYNE WA 6148

Trilab Pty Ltd ABN 25 065 630 506

Three individual soil specimens - Remoulded as

requested by the client (-4.75mmmaterial tested)SAND- white

The results of calibrations and tests performed apply only to the specific instrument or sample at the time of test unless otherwise clearly stated.

Reference should be made to Trilab's “Standard Terms and Conditions of Business” for further details.

Authorised Signatory

B. Brash

25 kPa

50.1 kPa

100 kPa

0

10

20

30

40

50

60

70

80

90

100

0 2 4 6 8 10 12

Sh

ear

Str

es

s (

kP

a)

Relative Displacement (mm)

Shear Stress/Displacement Plot

25 kPa

50.1 kPa

100 kPa

-0.10

0.10.20.30.40.50.6

0 2 4 6 8 10 12

Vert

ical D

isp

lacem

en

t (m

m)

Relative Displacement (mm)

Vertical Displacement/Relative Displacement Plot

Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations, and/or measurements included in this

document are traceable to Australian/National Standards.

Tested at Trilab Perth Laboratory

Authorised Signatory

C. Channon

ACCURATE QUALITY RESULTS FOR TOMORROW'S ENGINEERING

Page 14: 13.3 APPENDIX C SOIL TEST RESULTS · CLAYEY SAND - mottled red / grey DIRECT SHEAR TEST REPORT Residual @ 8 mm Displacement Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol

Brisbane

346A Bilsen Road,

Geebung

QLD 4034

Ph: +61 7 3265 5656

Perth

2 Kimmer Place,

Queens Park

WA 6107

Ph: +61 8 9258 8323Soil Rock Calibration

chrisc 1919

James

Client Report No.

Address

Project Test Date

Report Date

Client ID Depth (m)

10.00 20.00

1.50 1.90

NOTES/REMARKS: This is a computer generated plot so estimates may show some minor variations

from the results summarised.

Sample/s supplied by the client % Voids based on assumed SG of 2.48 Page 1 of 1 REP31302

Laboratory No. 9926

Maximum Dry Density (t/m3)

Trilab Pty Ltd ABN 25 065 630 506

Reference should be made to Trilab's “Standard Terms and Conditions of Business” for further details.

The results of calibrations and tests performed apply only to the specific instrument or sample at the time of test unless otherwise clearly stated.

0/19

14.9

Moisture Content (%) 2.3

1.69

Percentage of Oversize/Sieve Size (mm)

Optimum Moisture Content (%)

Sample 4

MOISTURE/DENSITY RELATIONSHIP TEST REPORTTest Method: AS 1289 5.1.1

Mindijup Landfill

P18020065-MDD

7/03/2018

6/03/2018

Not Supplied

Bowman & Associates Pty Ltd

PO Box 2059 ROSSMOYNE WA 6148

Authorised Signatory

A. Harrap

1.500

1.550

1.600

1.650

1.700

1.750

1.800

1.850

1.900

10.0 11.0 12.0 13.0 14.0 15.0 16.0 17.0 18.0 19.0 20.0

Dry

Den

sity

(t/

m3 )

Moisture Content (%)

Test Data MDD at OMC Cubic Spline Interpolation 0% Air Voids 2% Air Voids 4% Air Voids

Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations, and/or measurements included in

this document are traceable to Australian/National Standards.

Tested at Trilab Perth Laboratory.

Authorised Signatory

C. Channon

ACCURATE QUALITY RESULTS FOR TOMORROW'S ENGINEERING

Page 15: 13.3 APPENDIX C SOIL TEST RESULTS · CLAYEY SAND - mottled red / grey DIRECT SHEAR TEST REPORT Residual @ 8 mm Displacement Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol

Brisbane

346A Bilsen Road,

Geebung

QLD 4034

Ph: +61 7 3265 5656

Perth

2 Kimmer Place,

Queens Park

WA 6107

Ph: +61 8 9258 8323Soil Rock Calibration

Client Report No.

Address

Project Test Date

Report Date

Client ID

Description Sample Type

Failure Criteria

40.1 2.9 R2

Specimen Condition Shear Stress (kPa)

Specimen Dimensions (mm)

Rate of Strain (mm/min)

Initial Moisture Content (%)

Initial Wet Density(t/m3)

Notes/Remarks: Please review the results if the Cohesion is above 2 kPa when plotted with a line of best fit

Note: Area correction based on square sample equation.

Graph not to scale Sample/s supplied by the client Page 2 REP37101

Laboratory No. 9926

PO Box 2059 ROSSMOYNE WA 6148

0.991

14.5

100*100

The results of calibrations and tests performed apply only to the specific instrument or sample at the time of test unless otherwise clearly stated.

Reference should be made to Trilab's “Standard Terms and Conditions of Business” for further details.Trilab Pty Ltd ABN 25 065 630 506

Stage 3

Stage 2

Shear Angle (o)

Bowman & Associates Pty Ltd

20.8

DIRECT SHEAR TEST REPORT

Residual @ 7 mm Displacement

Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol. 2

Mindijup Landfill

25.0

Sample 4 Depth (m) Not Supplied

SAND- white Three individual soil specimens - Remoulded as

requested by the client (-4.75mmmaterial tested)

Stage 1

7/03/2018

16/03/2018

Cohesion (kPa)

P 18020065- DS

0.008

1.90

Inundated Normal Stress (kPa)

85.5

49.9

100.0

50.1

Authorised Signatory

B. Brash

0

20

40

60

80

100

0 20 40 60 80 100 120

Sh

ea

r S

tre

ss

(k

Pa

)

Normal Stress (kPa)

Residual - Normal Stress vs Shear Stress

Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations, and/or measurements included in this

document are traceable to Australian/National Standards.

Tested at Trilab Perth Laboratory

Authorised Signatory

C. Channon

ACCURATE QUALITY RESULTS FOR TOMORROW'S ENGINEERING

Page 16: 13.3 APPENDIX C SOIL TEST RESULTS · CLAYEY SAND - mottled red / grey DIRECT SHEAR TEST REPORT Residual @ 8 mm Displacement Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol

Brisbane

346A Bilsen Road,

Geebung

QLD 4034

Ph: +61 7 3265 5656

Perth

2 Kimmer Place,

Queens Park

WA 6107

Ph: +61 8 9258 8323Soil Rock Calibration

Client Report No.

Address

Project Test Date

Report Date

Client ID

Description Sample Type

Failure Criteria

40.6 6.2 R2

Specimen Condition Shear Stress (kPa)

Specimen Dimensions (mm)

Rate of Strain (mm/min)

Initial Moisture Content (%)

Initial Wet Density(t/m3)

Notes/Remarks: Please review the results if the Cohesion is above 2 kPa when plotted with a line of best fit

Note: Area correction based on square sample equation.

Graph not to scale Sample/s supplied by the client Page 3 REP37101

Laboratory No. 9926

Inundated

Peak

PO Box 2059 ROSSMOYNE WA 6148

7/03/2018

16/03/2018

Sample 4 Depth (m) Not Supplied

The results of calibrations and tests performed apply only to the specific instrument or sample at the time of test unless otherwise clearly stated.

Reference should be made to Trilab's “Standard Terms and Conditions of Business” for further details.Trilab Pty Ltd ABN 25 065 630 506

52.7

25.3

100.0

50.1

25.0

90.6

1.90

100*100

Stage 3

Stage 2

Stage 1

Cohesion (kPa)

Normal Stress (kPa)

0.008

14.5

SAND- white Three individual soil specimens - Remoulded as

requested by the client (-4.75mmmaterial tested)

Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol. 2

Shear Angle (o) 0.995

Bowman & Associates Pty Ltd

DIRECT SHEAR TEST REPORT

P 18020065- DS

Mindijup Landfill

Authorised Signatory

B. Brash

0

20

40

60

80

100

0 20 40 60 80 100 120

Sh

ea

r S

tre

ss

(k

Pa

)

Normal Stress (kPa)

Peak - Normal Stress vs Shear Stress

Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations, and/or measurements included in this

document are traceable to Australian/National Standards.

Tested at Trilab Perth Laboratory

Authorised Signatory

C. Channon

ACCURATE QUALITY RESULTS FOR TOMORROW'S ENGINEERING

Page 17: 13.3 APPENDIX C SOIL TEST RESULTS · CLAYEY SAND - mottled red / grey DIRECT SHEAR TEST REPORT Residual @ 8 mm Displacement Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol

Brisbane

346A Bilsen Road,

Geebung

QLD 4034

Ph: +61 7 3265 5656

Perth

2 Kimmer Place,

Queens Park

WA 6107

Ph: +61 8 9258 8323Soil Rock Calibration

Client Report No.

Address

Project Test Date

Report Date

Client ID

Description Sample Type

Notes/Remarks:

Photo not to scale Sample/s supplied by the client Page 4 REP37101

Laboratory No. 9926

PO Box 2059 ROSSMOYNE WA 6148

Depth (m) Not Supplied

SAND- white Three individual soil specimens - Remoulded as

requested by the client (-4.75mmmaterial tested)

The results of calibrations and tests performed apply only to the specific instrument or sample at the time of test unless otherwise clearly stated.

Reference should be made to Trilab's “Standard Terms and Conditions of Business” for further details.Trilab Pty Ltd ABN 25 065 630 506

DIRECT SHEAR TEST REPORTTest Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol. 2

Bowman & Associates Pty Ltd

Mindijup Landfill 7/03/2018

16/03/2018

Sample 4

P 18020065- DS

Authorised Signatory

B. Brash

Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations, and/or measurements included in this

document are traceable to Australian/National Standards.

Tested at Trilab Perth Laboratory

Authorised Signatory

C. Channon

ACCURATE QUALITY RESULTS FOR TOMORROW'S ENGINEERING

Page 18: 13.3 APPENDIX C SOIL TEST RESULTS · CLAYEY SAND - mottled red / grey DIRECT SHEAR TEST REPORT Residual @ 8 mm Displacement Test Method: AS 1289.6.2.2 / KH2 based on K.H. Head Vol

Vancouver Waste Disposal Facility - Application Licence Amendment

Prepared by Bowman & Associates Pty Ltd Page 73

13.4 APPENDIX D – ODOUR ASSESSMENT REPORT