Page 1: 11 Going Above & Beyond in Above Ground Storage Tank Equipment Solutions

11

Going Above & Beyond in Above Ground Storage Tank

Equipment Solutions

Page 2: 11 Going Above & Beyond in Above Ground Storage Tank Equipment Solutions

2

Going Above & Beyond in AST Solutions

The Only CARB-Certified AST Phase I EVR System in the Industry

The standards required by the California Air Resources Board (CARB) are among the most stringent in the world. Now – All OPW AST Products come standard with CARB AST-EVR Certification

Page 3: 11 Going Above & Beyond in Above Ground Storage Tank Equipment Solutions

3

301 Emergency Vent Valve

331/332 AST Spill Container

61fstop Overfill Prevention Valve

200TG Mechanical Tank Gauge

144TA and 444TA AST Tank Alarms

1711T /1711LPC Vapor Recovery Cap

21BV Full PortTwo-Way Ball Valve

199ASV Anti-Siphon Valve

821 Solenoid Valve

211-RMOT Remote-Fill Above

Ground Storage Tank Spill Container

61VSA Rotatable Swivel Adaptor

1611/1612 Kamvalok Poppeted Adaptor

CARB-Certified OPW AST Phase I EVR products ensure that you are provided unmatched environmental protection, durability and longer-life performance

Going Above & Beyond in a Class By Themselves

Page 4: 11 Going Above & Beyond in Above Ground Storage Tank Equipment Solutions

4

301 Emergency Vent Valve

• Weighted, mushroom-style emergency vent

• When AST pressure builds, weighted cast iron lid is forced up off seat to relieve pressure. When pressure is relieved, the lid lowers and is automatically reset.

• Unique seal design and stainless steel plate facilitates zero emissions

• Available in 3", 4", 6" and 8" openings with female NPT, male NPT or flanged connections (8" and 10") to allow for easy installation in new or existing above ground tanks

Page 5: 11 Going Above & Beyond in Above Ground Storage Tank Equipment Solutions

5

61ƒSTOP Overfill Prevention Valve with 1611/1612 Kamvalok Poppeted Adaptor

• The OPW 61fSTOP is designed to prevent overfilling of ASTs by providing a positive shut-off during a pressurized-fill (pump-on fill) delivery

• Incorporating the 1611/1612 Kamvalok Poppeted adaptor into the 61fSTOP prevents emissions into the atmosphere

• Available for both direct-fill and remote-fill applications

Time/Date Sample 1 Sample 2

Aug 18 70 Deg F

Start 2.08

5 min 2.08

30 min 2.08

Aug 19 100 Deg F

Start 2.03

5 min 2.04

30 min 2.09

Aug 19 0 Deg F

Start 2.15

5 min 2.04

30 min 2.12

Aug 18 Went into Soak

Aug 25 Came out of Soak

Sept 9 160 Deg F

Start 2.00

5 min 1.99

15 min 2.04

30 min 2.07

55 min 2.18

120 min 2.42Sept 9 0 Deg F

Start 2.10

5 min 2.20

30 min 2.42

Pressure Decay Test Results

* Unit of measurement of pressure decay test results is in WC

Page 6: 11 Going Above & Beyond in Above Ground Storage Tank Equipment Solutions

6

331 and 332 AST Direct-Fill Spill Container

• Catches spillage to help prevent soil contamination and groundwater pollution

• Special drain valve and one-piece casting base enables compliance with new CARB AST EVR standards

• Easy Installation – 4" and 6" NPT threaded base screws directly to the tank riser pipe

• Capacity: 7-gallon

OPW vs. Competitor

Valve Initial Pressure (ln wc)

Pressure after 5 minutes (ln wc)

OPW 2.2 2.2

OPW -2.0 -2.0

Competitor 2.0 0.9

Competitor -2.0 -0.8

TIMESample

1Sample

2Sample

3Sample

4Sample

5Sample

6Sample

7Sample

8

Day 1 70 Deg F

Start 2.08 2.08 2.08

5 min 2.11 2.11 2.06

30 min 2.13 2.12 2.11

Day 2 100 Deg F

Start 2.03 2.03 2.03

5 min 2.04 2.06 2.04

30 min 2.19 2.17 2.21

Day 2 0 Deg F

Start 2.15 2.15 2.15

5 min 2.20 2.09 2.12

30 min 2.08 2.08 2.12

Day 3 160 Deg F

Start 2.15 2.15 2.15 2.15 2.15

5 min 2.37 2.37 2.39 2.34 2.28

15 min 2.48 2.49 2.49 2.42 2.31

30 min 2.42 2.49 2.46 2.49 2.65

45 min 2.55 2.61 2.62 2.62 2.68

60 min 2.73 2.74 2.78 2.78 2.81

* Unit of measurement of pressure decay test results is in WC

Page 7: 11 Going Above & Beyond in Above Ground Storage Tank Equipment Solutions

7

211-RMOT Remote-Fill Spill Container

• Designed to prevent spilled product from entering soil near remote, horizontal-fill and vapor return connections on an above ground storage tank during normal tank filling operation

• Slips on the remote-fill and vapor return piping connected to an above ground tank

Page 8: 11 Going Above & Beyond in Above Ground Storage Tank Equipment Solutions

8

61VSA Rotatable Swivel Adaptor and 1711T-1711LPC Caps

• These adaptors and caps are installed on the vapor recovery riser pipe from an underground gasoline storage tank

• 61VSA Rotatable Swivel Adaptor– Mates with the vapor recovery elbow on the

delivery transport truck when recovery of gasoline vapors is required

– Features a top section that rotates with hose movement while the bottom section remains securely sealed to the 4 inch tank riser.

• 1711T & 1711LPC Caps– Feature enhanced ribbed seals and increased

sealing forces to provided a bubble tight seal

Page 9: 11 Going Above & Beyond in Above Ground Storage Tank Equipment Solutions

9

200TG Mechanical Tank Gauge

• Designed for reading liquid levels in horizontal or vertical above ground storage tanks with angled face for easy reading

• Provides accurate numerical counter readout, eliminating the need for any on-site manual gauging

• Vapor Tight – Allows for standard tank pressure testing, sealing up to 25-psig (1.72 bar)

• Available for tanks up to 40 feet

• English or Metric unit readouts

Page 10: 11 Going Above & Beyond in Above Ground Storage Tank Equipment Solutions

10

144TA & 444TA AST Four Signal Tank Alarm

• Designed to sense up to four different liquidlevels or other signals using just one device

• Audible Alarm – Sounds a 90-decibel alarm at 4 feet away

• Visual Notifications – Red alarm light will flash during use for notification to the user

• Intrinsically Safe – Complies with ANSI/UL 913 for Class 1, Division 1 & 2 for Groups C & D hazardous locations

• May be assembled remotely - up to 1,000 feet (304.8 meter) or directly on top of tank

• Up to four alarm signals – for high or low liquid level sensing, interstitial monitoring, and/or other signals in one to four separate tanks

444TA

144TA

Page 11: 11 Going Above & Beyond in Above Ground Storage Tank Equipment Solutions

11

199ASV Anti-Siphon Valve/21BV Ball Valve/821 Solenoid Valve

• Designed to help prevent siphoning of an above ground storage tank, should a leak or break occur in the fuel supply line

• Installs on the top of an aboveground storage tank with a suction rod on the inlet and the fuel supply line (to a remote pump) on the outlet of the valve

• Available in female NPT threads with four different factory-adjusted hydrostatic head pressure settings

• Used throughout fueling systems where a shut-off point is desirable to isolate a section of the piping system

• Compatible with gasoline, alcohol fuels, diesel and MTBE

• Designed to prevent accidental siphoning of above ground storage tanks if a leak or break occurs in the fuel supply line

• A two-way, normally closed diaphragm valve that opens when energized to allow fuel to flow to the pump or dispenser

• Available in female NPT threads

199ASV Anti-Siphon Valve

21BV Full PortTwo-Way Ball Valve

821 Solenoid Valve

Page 12: 11 Going Above & Beyond in Above Ground Storage Tank Equipment Solutions

12

Micro Website

PowerPoint Presentations

Brochures

Trade Publication Ads

Trade Show Graphics

Publicity

– Press Releases

– Email Blasts

Mini-AST Catalog

Counter Mat

Going Above & Beyond – Sales Support Tools

Page 13: 11 Going Above & Beyond in Above Ground Storage Tank Equipment Solutions

13

Going Above & Beyond – OPW AST Product Summer Sale

Page 14: 11 Going Above & Beyond in Above Ground Storage Tank Equipment Solutions

14

Going Above & Beyond – OPW AST Product Summer Sale

Page 15: 11 Going Above & Beyond in Above Ground Storage Tank Equipment Solutions

15

Going Above & Beyond – OPW AST Product Summer Sale

Sale only applies to products listed above.

Page 16: 11 Going Above & Beyond in Above Ground Storage Tank Equipment Solutions

16

• The highest level of protection against AST emissions• Helps to protect the air we breathe• Affordable – System comparably priced with non-CARB certified products• Special Summer Sale – To help you sell more AST Products

OPW AST System Offers Best Overall Value in the Industry

Going Above & Beyond – AST Product Solutions

Page 17: 11 Going Above & Beyond in Above Ground Storage Tank Equipment Solutions

17

Thank You!

Going Above & Beyond – AST Product Solutions