11 case for co axis angled implants

46
Guide Right™ CASE FOR ANGLED IMPLANTS ZHEN 2.2013 # 10 & # 6 Vacuform Shell Offset Guide Posts Open Guide Sleeves Evaluation using Software Lineal Corrections Angular Corrections I nvi vo5 Featuring :

Upload: cmeitner

Post on 02-Jun-2015

248 views

Category:

Health & Medicine


2 download

DESCRIPTION

Guide Right Surgical Guide System: fabrication and correction of Diagnostic & Surgical Guides with 2D & 3D X-ray Images

TRANSCRIPT

Page 1: 11 case for co axis angled implants

Guide Right™

CASE FOR ANGLED IMPLANTS

ZHEN 2.2013

# 10 & # 6 Vacuform Shell Offset Guide Posts Open Guide Sleeves Evaluation using Software Lineal Corrections Angular Corrections

Invivo5

Featuring:

Page 2: 11 case for co axis angled implants

Vacuform 3 mm guide posts 3 mm guide sleeves

Fabrication of DIAGNOSTIC guide

Page 3: 11 case for co axis angled implants

Cast of the patient as he presented at initial exam.

Page 4: 11 case for co axis angled implants

Temporary partial denture

Page 5: 11 case for co axis angled implants

Impression and cast with partial denture in place.

Page 6: 11 case for co axis angled implants

Vacuform shell on cast marked to indicate the planned axis holes for the implants.

Page 7: 11 case for co axis angled implants

Holes are drilled through the plastic shell into the incisal edge with 3/32” drills.

Page 8: 11 case for co axis angled implants

Vacuform shell on cast with holes drilled indicatingthe proposed axis holes for the implants.

Page 9: 11 case for co axis angled implants

The vacuform shell removed.

Page 10: 11 case for co axis angled implants

The drills are removed and replaced with two short 3 mm straight guide posts.

Page 11: 11 case for co axis angled implants

3 mm diagnostic guide sleeves (with 1 cleat) are placed on the guide posts with cleats positioned on the palatal surface.

Page 12: 11 case for co axis angled implants

Triad® Gel is applied capturing the cleats on the guide posts and adjacent teeth to form the DIAGNOSTIC guide

which is used for the cone beam imaging.

Page 13: 11 case for co axis angled implants

PREOPERATIVE

Software EvaluationInvivo5 Anatomage

# 6

Page 14: 11 case for co axis angled implants

# 6Initial Alignment of guide sleeve with implant

axial cross sectional

tangential view volumetric

Invivo5 Anatomage

Page 15: 11 case for co axis angled implants

Cone beam image showing alignment of the guide sleeve in the # 6 position. A 12 º bend is required for this site.

# 6Utilizing 12º Angled Southern Implant ▪

axial cross sectional

tangential view volumetric

Invivo5 Anatomage

Page 16: 11 case for co axis angled implants

Southern Implant & Guide Right™ Guide Sleeve in Place

▪ 12º facial correction needed to place implant ▪

cross sectional view

#6

Invivo5Anatomge

Page 17: 11 case for co axis angled implants

# 6Initial Alignment of guide sleeve with implant

axial cross sectional

tangential view volumetric

Invivo5 Anatomage

Page 18: 11 case for co axis angled implants

The guide sleeve is in line with the virtual implant, but close to root of #5. So a 1.5 mm offset post will be used to move the position of the guide sleeve to the mesial.

# 6

tangential viewInvivo5

Anatomage

Page 19: 11 case for co axis angled implants

PREOPERATIVE

Software EvaluationInvivo5 Anatomage

# 10

Page 20: 11 case for co axis angled implants

Invivo5Anatomage ▪ Initial Alignment ▪

occlusal cross sectional

tangential view volumetric

Invivo5Anatomage

#10Showing virtual implant and the guide sleeve in two planes.

Page 21: 11 case for co axis angled implants

#10 A Southern 12° Co-axis Implant will be used, Angular Correction for guide sleeve: 12º toward the facial

Invivo5Anatomage

cross sectional

Page 22: 11 case for co axis angled implants

Invivo5Anatomage

▪ Southern Implant 12º co-axis virtual image ▪

Linear Correction:

1 mm offset guide post > moving closer to root of # 11

# 10

tangential viewInvivo5Anatomage

Page 23: 11 case for co axis angled implants

Fabrication of SURGICAL guide

Magnetic Guide Posts

Open Guide Sleeves

Page 24: 11 case for co axis angled implants

Fabrication of SURGICAL Guide

Magnetic Guide Posts

Open Guide Sleeves

Page 25: 11 case for co axis angled implants

Corrected magnetic offset guide posts in place: # 6 > 1.5 mm offset guide post to move mesially, away from # 5 #10 > 1.0 mm offset guide post to move distally, closer to # 11

Page 26: 11 case for co axis angled implants

3.3 mm open guide sleeves positioned over the magnetic guide posts with cleats positioned toward the palatal surface.

Page 27: 11 case for co axis angled implants

Triad® Gel is added to form the completed SURGICAL guide.

Page 28: 11 case for co axis angled implants

POST-OPERATIVE

Final X-rays

Page 29: 11 case for co axis angled implants

Final X-rays of implant placement

# 10# 6

Page 30: 11 case for co axis angled implants

RESTORATION

Page 31: 11 case for co axis angled implants

Axis indicator (3 mm guide posts) in place

Page 32: 11 case for co axis angled implants

Posts indicating the long axis of the abutments

Page 33: 11 case for co axis angled implants

Atlantis abutments

Page 34: 11 case for co axis angled implants

Final restoration

Page 35: 11 case for co axis angled implants

Final restoration

Page 36: 11 case for co axis angled implants

Atlantis Abutment

Page 37: 11 case for co axis angled implants

Final Restoration

Page 38: 11 case for co axis angled implants

Final Restoration

Page 39: 11 case for co axis angled implants

Step 2 Locate 3/32” hole in the center of the v-cut and place the bottom half of the guide post into the hole. Tighten the set screw.

Step 1 Place bending tool plate on a secure flat surface with the degree increments at the top & the stainless steel bar with the v-cut at the bottom.

Step 3 Locate the hole in the bottom of the stylus that you will use that will fit over the top half of the guide post (3.0 mm, 4.0 mm or 5.0 mm).

Step 5 Using the stylus as a lever, bend the guide post to the degree of angle of correction. You may need to ease the point of the stylus beyond the point of the desired degree.

Step 6 Loosen screw and remove guide post and the stylus to find the guide post bent to the desired angle.

Step 4 Fit the stylus over the guide post securely with the point directed at zero degrees and the bottom of the stylus in contact with the V block.

Guide Right™ GENERATION II BENDING TOOL

SINGLE BEND review

Page 40: 11 case for co axis angled implants

COMPOUND BEND overview

Step 1 Position a straight or offset guide post in the bending plate, tightening the set screw against one of the flat surfaces on the lower half of the guide post.

Step 4 The 2nd bend in the second plane is made after rotating the guide post up away from the surface of the bending plate to register the stylus point back at 0 degrees.Step 5 Slide the stylus support bar down under the stylus until it supports the stylus. Tighten the side screws before making the second bend.

Step 7 Remove the stylus and place the guide post back in the cast with the appropriate side indicated by a mark facing the buccal or lingual surface.

Be sure the post is in the correct position.If the post needs to be corrected by a linear movement an offset guide post can be used.

Off sets available in the 3 mm guide post: 0.5,1,1.5, 2.0 ,or 3.0 mm.

Step 3 The set screw is loosened and the guide post is rotated 90 ° next flat surface.

Step 2 The 1st bend can be made to the right or left direction.

Step 6 The second bend can be made in either direction according to the x-ray.

Guide Right™ GENERATION II BENDING TOOL

Page 41: 11 case for co axis angled implants

Guide Right™

Generation ll Bending Tool

For more information on use of the bending tool go towww.deplaque.com ▪ Guide Right™ Generation ll Bending Tool

10 ° example

Page 42: 11 case for co axis angled implants

Close up of Offset Guide Posts in bending block

Guide Right™

Generation ll Bending Tool

Page 43: 11 case for co axis angled implants

Magnetic Guide Posts

Straight 3.0 mm od Offset

3.0 od X 0.5 mm os

3.0 od X 1.0 mm os

3.0 od X 1.5 mm os

3.0 od X 2.0 mm os

3.0 od X 2.5 mm os

3.0 od X 3.0 mm os

Page 44: 11 case for co axis angled implants

Guide Right™ Products shown in this case

2 - 3/32” Drill

2 - 3 mm Straight Guide Posts (short)

2 - 3 mm Guide Sleeves

1 - 3 mm X 1.0 mm Offset Magnetic Guide Post

1 - 3 mm X 1.5 mm Offset Magnetic Guide Post

2 - 3 mm Open Guide Sleeve

Generation ll Bending Tool

Triad® Gel

Page 45: 11 case for co axis angled implants

In-office or lab fabrication

Evaluate with 2D & 3D imaging

Allows linear and angular correction

Enables precision implant placement

Cost effective

A System of Components

for the fabrication and correction of DIAGNOSTIC & SURGICAL guides in one or two dimensions

1.800.314.0065 • www.deplaque.com

Page 46: 11 case for co axis angled implants

Guide Right™ Surgical Guide System

Start With Precision. Place With Confidence.™

1.800.314.0065 • www.deplaque.com

fabricate ▪ evaluate ▪ correct ▪ verify ▪ place