101)科學工業園區人才培育補助計畫...
TRANSCRIPT
-
1
(101) ()
101 7 1 102 8 31
-
2
3
5
5
5
17
21
23
-
3
( )
100
231 99 (//)
(-()) (-() (-)
A() B C
600,000
666,667 66,667
02-82122822 02-82122829
E-mail [email protected]
02-82122822 02-82122829
E-mail [email protected]
02-82122829
02-82122000 2841
E-mail [email protected]
-
4
()
()
4
1. Antenna Design & Manufacture
2. RF Connector & Cable Assembly
3. Vehicle Electronics
4. LED Development & Manufacture
4
()
()
EMI
:
-
5
Conformance test
Last
Mile
2/3 1/3
/
()
3 1 18
6 ()
3 1 18
6
3 1.5 27
3 1 18
6 ()
-
6
()
1
()
//
/
101 101
:
:20 36 18 54
3
101 101
:
:20 36 18 54
3
101 101
:
:20 36 18 54
3
101 101
:
:20 27 27 54
3
80 135 81 216 12
2
101
101
(EMC)
(EMI)
(TX)(RX)(:
-
7
)
1. EMC EMI
2. EMS
3. RF/EMC
4. RF/EMC
5.
6.
7.
101
101
CAD
1.
2.
3.
4.
5.
6.
101
101
MIMOMultiple InputMultiple Output
MIMO
Diversity Reception
-
8
MIMO
:
( SAR//HAC)
101
101
1. Overview microwave filter
2. Periodic structures
3. filter design by the image parameter method
4. filter design by the insertion loss method
5. filter transformations
-
9
()/
1./
2.
(1)
a. AM/FM ( LNA
)
b. CMMB (DVB-T)( LNA
)
c. WiFi ()
d. ()
(2)
7m*4m*3m
400MHz~6GHz 2
/
EMI 7m*4m*3m
30MHz~1GHz 1
3MHz~8.5GHz 10 /
10KHz~26.5GHz 6 /
-
10
1GHz 2
6GHz 1
30KHz~6GHz 2 /
30MHz~1GHz 1
PCB 2 /
(3)/
()
() 40 500/
20,000
( I-Pex ) 40 100/ 4,000
40 700/ 28,000
24 50/ 1,200
20 100/ 2,000
1 157/ 157
5 4500/ 22,500
5 1000/ 5,000
82,857
-
11
(4)/
():
(5)/
()
60%
40%
(6)
//
(Experimental Study)
(Matlab)(Ansoft HFSSSpeed 2000Microwave Office)
//
Noise Floor Co-located SAR
-
12
()
(/)
101 11
1.
2.
3.
102 5
1.
2.
3.
()()
20% 50%(
) 50%
()()
172
/
()
/
36
/
36
/
36
/
36
-
13
/
()
18
18
18
18
()()
(//
)
()
1. //
2. (Experimental
-
14
Study)
3. (Matlab)(Ansoft HFSSSpeed
2000Microwave Office)
4.
5. //
Noise Floor
Co-located SAR
6.
1. 20
2. 4
3. AM/FM
LNA
4. CMMB (DVB-T)
LNA
5. WiFi
6. ()
7. () 5
8. 3
9. 3
-
15
()
/
/ / (102 1 -102 3 ) (102 7 -102 8 )
1. AM/FM
LNA
2. CMMB (DVB-T)
LNA
3. WiFi
4. ()
4 240 /
()
1.
1990 &
LED
-
16
2.
14
3.
4
(
)
(Re-engineering)
(1). AM/FM LNA
(2). CMMB (DVB-T) LNA
(3). WiFi
(4). ()
4.
(1).
(2). ()
60% 40%
-
17
5.()
(1).
(2).
(3).
(4).
6.
(1).
( 50%)
(2).
( 50%)
()()
1.
Performance testConformance test
2.
-
18
3.
Last mile
()
1. //
2. (Experimental
Study)
3. (Matlab)(Ansoft HFSSSpeed
2000Microwave Office)
4.
5. //
Noise Floor Co-located
SAR
-
19
\
101
2
3
4
5
6
7
8
9
10
11
12
102
1
2
3
4
5
6
7
8
1
*1
2
*2
3
*3
4 ()
*4
5
*5
6
*6
7 ()
*7
8
*8
9
*9
() 10 30 50 60 80 100
-
20
*1. 101.2 101.4
*2. 101.3 101.5
*3. 101.6 101.8
*4. () 101.9
102.1
*5. 101.12.1 101.12.31
*6. 102 2 102.1 102.3
*7. ()
102.3
102.6
*8. 102.7 102.8
*9. 102.8
102.8
-
21
/
/
14
/
/
12
/
/
12
38
-
22
-
101
(____)
( 221 ) 276 7
www.wieson.com
&RF&LED
10 11-20 21-50 51-100 101-300
300-500 501-1000 1001-2000 2001-3000 3001
//
(02 ) 26471896 ext. 6377 ( 02 ) 26471566 email [email protected] 0920137075
(____)
66 10
www.hp.com.tw
10 11-20 21-50 51-100 101-300
300-500 501-1000 1001-2000 2001-3000 3001
-
23
//
(02 ) 87229000 ( 02 ) 25106491 email [email protected] 0928387372
(____)
88 21 (221) www.wistron.com.tw
10 11-20 21-50 51-100 101-300
300-500 501-1000 1001-2000 2001-3000 3001
//
(02 )66169999 ext.2899 ( 02 ) 66122233 email [email protected] 0910088500
(____)
88 8 (221) www.acer.com.tw
10 11-20 21-50 51-100 101-300
300-500 501-1000 1001-2000 2001-3000 3001
-
24
//
(02 )26963131 ( 02 ) 86913255 email [email protected] 0928737695
(____)
150 13 1
www.arrow.com
10 11-20 21-50 51-100 101-300
300-500 501-1000 1001-2000 2001-3000 3001 / / (02 )77225168 ( 02 ) 77238168 email [email protected] 0921821258
(____)
157 www.bsmi.gov.tw
10 11-20 21-50 51-100 101-300
300-500 501-1000 1001-2000 2001-3000 3001 / / (02 )86488058 ext.636 ( 02 ) 86484210
-
25
email [email protected] 0935885350
/ /
_____________________________________
1 3 /
-
26
-
101
/
_____________________
/
1 /400MHz~6GHz EMI 1 /30MHz~1GHz 7 /3MHz~8.5GHz 4 /10KHz~26.5GHz
25
/ /
02-82122822 02-82122829 email [email protected] / 02-82122000 ext. 2841 02-82122000 email [email protected] 0921880693
1. 2.
-
27
-
101
(O)02-82122822
(H)
(O)02-82122829
(H)
231 99
_______
/
7
(:___________________)
/
231 99
(
10 11-20 21-50 51-100 101-300
300-500 501-1000 1001-2000 2001-3000 3001
() 36 36
-
28
//////
/ TAF NCC TAF ISO 17025
TAF TAF
(O)02-82122822
(H)
(O)02-82122829
(H)
231 99
_______
/
2
2
(:___________________)
-
29
/
231 99
(
10 11-20 21-50 51-100 101-300
300-500 501-1000 1001-2000 2001-3000 3001
() 36 36
///
/ /
/ AuTO CAD Pro.
TAF ISO 17025TAF TAF
(O)0928387372
(H)02-87229000
(O)02-25106491
(H)
66 10
_______
/
6
4
2
-
30
(:___________________)
/
/
66 10
(
10 11-20 21-50 51-100 101-300
300-500 501-1000 1001-2000 2001-3000 3001
() 18
()
/
[email protected] (02 )26963131 ( 02 ) 86913255
88 8 (221)
_______
/
10
(:___________________)
-
31
/ /
88 8 (221)
(
10 11-20 21-50 51-100 101-300
300-500 501-1000 1001-2000 2001-3000 3001
() 18
/
[email protected] (02 )66169999 ext.2899 ( 02 ) 66122233
88 21 (221)
_______
/
13
(:___________________)
-
32
/ /
88 21 (221)
(
10 11-20 21-50 51-100 101-300
300-500 501-1000 1001-2000 2001-3000 3001
() 18
/
[email protected] (02 )77225168 ( 02 ) 77238168
150 13 1
_______
/
14
(:___________________)
/ /
150 13 1
-
33
(
10 11-20 21-50 51-100 101-300
300-500 501-1000 1001-2000 2001-3000 3001
() 18
/
-
34
-
101
101 36
(:Antennas : John D. Kraus )
/
MIMOMultiple
InputMultiple OutputMIMO
Diversity Reception
MIMO
:
( SAR//HAC)
-
35
101 36
(: Electromagnetic Compatibility
: Clayton Paul )
/
(EMC)(EMI)
(TX)(RX)(:
)
1. EMC EMI
2. EMS
3. RF/EMC
4. RF/EMC
5.
6.
7.
-
36
101 36
(: : )
/
1.
2. Overview microwave filter
3. Periodic structures
4. filter design by the image parameter method
5. filter design by the insertion loss method
6. filter transformations
-
37
101 36
(: Microwave Engineering
: David M. Pozar )
/
CAD
1.
2.
3.
4.
5.
6.
-
38
101 18
-
39
/
MIMO
(MIMO)
MIMO
(WLAN) MIMO
MIMO
MIMO
MIMO
MIMO
(network-aware)
MIMO
-
40
101 18
/
1.
2. EMC
3. EMC ()
8. EMC ()
-
41
101 18
(: : )
/
1.
2. LC
3.
4.
-
42
101 18
/
Smith Chart
( ADS)
-
43
-
101
(____)
( 221 ) 276 7
www.wieson.com
&RF&LED
10 11-20 21-50 51-100 101-300
300-500 501-1000 1001-2000 2001-3000 3001
//
(02 ) 26471896 ext. 6377 ( 02 ) 26471566 email [email protected] 0920137075
4 240 /
_____________________
_____________________________________
-
44
-
101
(O)26471896ext.6612
(H)
(O)26471566
(H) ( 221 ) 276 7
_______
/
14
( 221 ) 276 7
10 11-20 21-50 51-100 101-300
300-500 501-1000 1001-2000 2001-3000 3001
4 240 /
/