100w uv cob flood · 100 u co flood user manual 6 dmx mode: operating in a dmx control mode...

12
Order code: LEDJ187 100W UV COB Flood User Manual

Upload: others

Post on 06-Apr-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 100W UV COB Flood · 100 U CO Flood User Manual 6 DMX mode: Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating

Order code: LEDJ187

100W UV COB Flood User Manual

Page 2: 100W UV COB Flood · 100 U CO Flood User Manual 6 DMX mode: Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating

www.prolight.co.uk 100W UV COB Flood User Manual 2

Safety advice

WARNINGFOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP!• Beforeyourinitialstart-up,pleasemakesurethatthereisnodamagecausedduringtransportation.

• Shouldtherebeanydamage,consultyourdealeranddonotusetheequipment.

• Tomaintaintheequipmentingoodworkingconditionandtoensuresafeoperation,itisnecessaryfortheusertofollowthesafetyinstructionsandwarningnoteswritteninthismanual.

• Pleasenotethatdamagescausedbyusermodificationstothisequipmentarenotsubjecttowarranty.

IMPORTANT:The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorised modification to the equipment.

OPERATING DETERMINATIONSIfthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageandthewarrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.

Donotendangeryourownsafetyandthesafetyofothers!

Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.

CAUTION!KEEP THIS EQUIPMENT AWAY FROM RAIN, MOISTURE AND LIQUIDS

CAUTION! TAKE CARE USING THIS EQUIPMENT!HIGH VOLTAGE-RISK OF ELECTRIC SHOCK!!

• Neverletthepowercablecomeintocontactwithothercables.Handlethepowercableandallmainsvoltageconnectionswithparticularcaution!

• Neverremovewarningorinformativelabelsfromtheunit.

• Donotopentheequipmentanddonotmodifytheunit.

• Donotconnectthisequipmenttoadimmerpack.

• Donotswitchtheequipmentonandoffinshortintervals,asthiswillreducethesystem’slife.

• Onlyusetheequipmentindoors.

• Donotexposetoflammablesources,liquidsorgases.

• Alwaysdisconnectthepowerfromthemainswhenequipmentisnotinuseorbeforecleaning!Onlyhandlethepower-cablebytheplug.Neverpullouttheplugbypullingthepower-cable.

• Makesurethattheavailablemainssupplyvoltageisbetween100~240VAC,50/60Hz.

• Makesurethatthepowercableisnevercrimpedordamaged.Checktheequipmentandthepowercableperiodically.

• Iftheequipmentisdroppedordamaged,disconnectthemainspowersupplyimmediatelyandhaveaqualifiedengineerinspecttheequipmentbeforeoperatingagain.

• Iftheequipmenthasbeenexposedtodrastictemperaturefluctuation(e.g.aftertransportation),donotconnectpowerorswitchitonimmediately.Thearisingcondensationmightdamagetheequipment.Leavetheequipmentswitchedoffuntilithasreachedroomtemperature.

• Ifyourproductfailstofunctioncorrectly,stopuseimmediately.Packtheunitsecurely(preferablyintheoriginalpackingmaterial),andreturnittoyourProLightdealerforservice.

• Onlyusefusesofsametypeandrating.

• Repairs,servicingandpowerconnectionmustonlybecarriedoutbyaqualifiedtechnician.THISUNITCONTAINSNOUSERSERVICEABLEPARTS.

• Thislightingfixtureisforprofessionaluseonly-itisnotdesignedfororsuitableforhouseholduse.Theproductmustbeinstalledbyaqualifiedtechnicianinaccordancewithlocalterritoryregulations.Thesafetyoftheinstallationistheresponsibilityoftheinstaller.Thefixturepresentsrisksofsevereinjuryordeathduetofirehazards,electricshockandfalls.

• Warning!RiskGroup2LEDproductaccordingtoEN62471.Donotviewthelightoutputwithopticalinstrumentsoranydevicethatmayconcentratethebeam.

• WARRANTY:Oneyearfromdateofpurchase.

Page 3: 100W UV COB Flood · 100 U CO Flood User Manual 6 DMX mode: Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating

www.prolight.co.uk 100W UV COB Flood User Manual 3

Product overview & technical specifications

FeaturingCOBtechnologythisrobustfloodisloadedwitha100WUVLEDwhichishousedina80°reflectorandsuppliedwiththreebeamreductionlenses(25°,40°and50°).ThisfixturehasbeendesignedtofillavarietyofvenueswithanoutstandingUVglowandiseasytotransportandinstall.ThehighoutputLEDisidealforwashingstages,nightclubs,bowlingcentresandskatingrinks.

100W UV COB Flood

257mm 245mm

310mm

•1x100WUVCOBLED

•Beamangle:80°native,25°,40°and50°beamreductionlensessupplied

•Ultravioletwavelength:400nm

•1.1kHzrefreshrate

•DMXchannels:1or2selectable

•Staticandsoundactivemodes

•0-100%dimmingandvariablestrobe

•Bracketallowsformultipleriggingandfloorstandingapplications

•4pushbuttonmenuwithLEDdisplay

•PowerCONinput/output

•3-PinXLRinput/output

•Fancooled

Specifications 100W UV COB Flood

Powerconsumption 105W

Powersupply 100~240V,50/60Hz

Fuse T2A250V

Dimensions 310x257x245mm

Weight 3.6kg

Ordercode LEDJ187

Page 4: 100W UV COB Flood · 100 U CO Flood User Manual 6 DMX mode: Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating

www.prolight.co.uk 100W UV COB Flood User Manual 4

Technical specifications

01-Earthpoint

02-Safetyeye

03-LEDdisplay

04-Functionbuttons

05-3-PinDMXinput

06-3-PinDMXoutput

07-PowerCONinput

08-PowerCONoutput

09-FuseT2A250V

10-Hangingbracket

11-Hangingbracketadjustableknob

Inthebox:1 x fixture, 1 x 25° beam reduction lens, 1 x 40° beam reduction lens, 1 x 50° beam reduction lens, 1 x power cable & 1 x user manual

100W UV COB Flood

MENU

DMX INPUT

POWER INPUT:100-240V~50/60Hz

FUSE:T2A 250V

POWER OUTPUT:100-240V~50/60Hz

DMX OUTPUT

UPENTER DOWN

www.prolight.co.uk

10

05

11

07

0901 02

04

03

11

10

06

08

Page 5: 100W UV COB Flood · 100 U CO Flood User Manual 6 DMX mode: Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating

www.prolight.co.uk 100W UV COB Flood User Manual 5

Operating instructions

MENU

S L A u Slave mode

d o n

d o n

d o F FDisplay backlight

S t n d

rEv Display inverse

d E F A Reset factory settings

S J - 1

S J - 8

Sound active/sound sensitivityS J - 5

U. 0 0 0

U. 2 5 5

F 5. 0 0

F 5. 1 5

Manual dimming modeU. 2 5 5

d. 0 0 1

d. 5 1 2

C h 0 1

C h 0 2

DMX address/channel settingd. 0 0 1

Page 6: 100W UV COB Flood · 100 U CO Flood User Manual 6 DMX mode: Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating

www.prolight.co.uk 100W UV COB Flood User Manual 6

DMX mode:

OperatinginaDMXcontrolmodeenvironmentgivestheuserthegreatestflexibilitywhenitcomestocustomisingorcreatingashow.Inthismodeyouwillbeabletocontroleachindividualtraitofthefixtureandeachfixtureindependently.

ToaccesstheDMXaddressmode,pressthe“MENU”buttonontherearoftheunittoshowd.001ontheLEDdisplay.Nowusethe“UP”and“DOWN”buttonstosettherequiredDMXaddress.Pressthe“ENTER”buttontoconfirmthesetting. TheDMXchannelmodewillnowbedisplayed,usethe“UP”and“DOWN”buttonsontherearoftheunittoselecteither1or2DMXchannelmode.Pressthe“ENTER”buttontoconfirmthesetting.

Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.

Master/slave mode:

Tosetthemasterunit,pressthe“MENU”buttonontherearofthemasterunitthenselectyourdesiredprogram(soundactiveordimmermodes).Tosettheotherunitsinslavemode,pressthe“MENU”buttonontherearoftheunittoshowSLAuontheLEDdisplayandpressthe“ENTER”buttontocon-firmthesetting.Theunitswillnowruninsequencewiththemasterunit.Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.

PleaseensurethatallslaveunitsaresettothesameDMXchannelmodeasthemasterunit.

Manual dimming mode:

Toaccessthemanualdimmingmode,pressthe“MENU”buttonuntilthedisplayshowsU.255ontheLEDdisplay.Usethe“UP”and“DOWN”buttonstoselecttherequiredbrightnessfromU.000~U.255.Toadjusttheflashspeedpressthe“ENTER” buttonandthenusethe“UP”and“DOWN”but-tonstoselectanyvaluefromF5.00~F5.15.Pressthe“ENTER” buttontoconfirmthesetting.

Value: 000 - 255 (000 = low brightness, 255 = high brightness) Value: 00 - 15 (00 = no flash, 15 = fast flash speed)

Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.

Operating instructions

Channel Value Function

1 000-255 Masterdimmer(0-100%)

2 000-015 Nofunction

016-255 Strobe(slow-fast)

2 channel mode:

Channel Value Function

1 000-255 Masterdimmer(0-100%)

1 channel mode:

Page 7: 100W UV COB Flood · 100 U CO Flood User Manual 6 DMX mode: Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating

www.prolight.co.uk 100W UV COB Flood User Manual 7

Operating instructions

Sound active:

Toaccessthesoundactivemode,pressthe“MENU”buttonuntilthedisplayshowsSJ-5ontheLEDdisplay.Usethe“UP”and“DOWN”buttonstoselecttherequiredsoundsensitivityfromSJ-1~SJ-8.Pressthe“ENTER” buttontoconfirmthesetting.

Value: 1 - 8 (1 = low sensitivity, 8 = high sensitivity)

Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.

Display backlight:

Toaccessthedisplaybacklightsetting,pressthe“MENU”buttonuntilthedisplayshowsdonontheLEDdisplay.Usethe“UP”and“DOWN”buttonstoselecteitherdon(displaybacklighton)~doff(displaybacklightoff).Pressthe“ENTER” buttontoconfirmthesetting.

Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.

Display inverse:

Toaccessthedisplayinversesetting,pressthe“MENU”buttonuntilthedisplayshowsdonontheLEDdisplay.Pressthe“ENTER” buttontodisplayStndandusethe“UP”and“DOWN”buttonstoselecteitherStnd(displaystandard)~ (displayinverse).Pressthe“ENTER” buttontoconfirmthesetting.

Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.

Reset factory settings:

Toresetthefactorysettings,pressthe“MENU”buttonuntilthedisplayshowsdonontheLEDdisplay.Pressthe“ENTER” buttontwicetodisplaydEFa.Pressthe“UP”and“DOWN”buttonstogetherandthefixturewillberesettoitsfactorysettings.

Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.rEv

Page 8: 100W UV COB Flood · 100 U CO Flood User Manual 6 DMX mode: Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating

www.prolight.co.uk 100W UV COB Flood User Manual 8

Setting the DMX address:

TheDMXmodeenablestheuseofauniversalDMXcontroller.Eachfixturerequiresa“startaddress”from1-511.Afixturerequiringoneormorechannelsforcontrolbeginstoreadthedataonthechannelindicatedbythestartaddress.Forexample,afixturethatoccupiesoruses7channelsofDMXandwasaddressedtostartonDMXchannel100,wouldreaddatafromchannels:100,101,102,103,104,105and106.Chooseastartaddresssothatthechannelsuseddonotoverlap.E.g.thenextunitinthechainstartsat107.

DMX 512:

DMX(DigitalMultiplex)isauniversalprotocolusedasaformofcommunicationbetweenintelligentfixturesandcontrollers.ADMXcontrollersendsDMXdatainstructionsformthecontrollertothefixture.DMXdataissentasserialdatathattravelsfromfixturetofixtureviatheDATA“IN”andDATA“OUT”XLRterminalslocatedonallDMXfixtures(mostcontrollersonlyhaveadata“out”terminal).

DMX linking:

DMXisalanguageallowingallmakesandmodelsofdifferentmanufacturestobelinkedtogetherandoperatefromasinglecontroller,aslongasallfixturesandthecontrollerareDMXcompliant.ToensureproperDMXdatatransmission,whenusingseveralDMXfixturestrytousetheshortestcablepathpossible.TheorderinwhichfixturesareconnectedinaDMXlinedoesnotinfluencetheDMXaddressing.Forexample;afixtureassignedtoaDMXaddressof1maybeplacedanywhereinaDMXline,atthebeginning,attheend,oranywhereinthemiddle.WhenafixtureisassignedaDMXaddressof1,theDMXcontrollerknowstosendDATAassignedtoaddress1tothatunit,nomatterwhereitislocatedintheDMXchain.

DATA cable (DMX cable) requirements (for DMX operation):

ThisfixturecanbecontrolledviaDMX-512protocol.TheDMXaddressissetonthebackoftheunit.YourunitandyourDMXcontrollerrequireastandard3-pinXLRconnectorfordatainput/output,seeimagebelow.

Note: DMX cable must be daisy chained and cannot be split.

DMX setup

FurtherDMXcablescanbepurchasedfromallgoodsoundandlightingsuppliersorProLightConceptsdealers.Pleasequote:

CABL10 – 2mCABL11 – 5mCABL12 – 10m

Page 9: 100W UV COB Flood · 100 U CO Flood User Manual 6 DMX mode: Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating

www.prolight.co.uk 100W UV COB Flood User Manual 9

Notice:

Besuretofollowthediagramsbelowwhenmakingyourowncables.DonotconnectthecablesshieldconductortothegroundlugorallowtheshieldconductortocomeincontactwiththeXLRsoutercasing.Groundingtheshieldcouldcauseashortcircuitanderraticbehaviour.

Special note:

Line termination:

Whenlongerrunsofcableareused,youmayneedtouseaterminatoronthelastunittoavoiderraticbehaviour.

Using a cable terminator will decrease the possibilities of erratic behaviour. (3-pin - Order ref: CABL90, 5-pin - Order ref: CABL89)

5-pin XLR DMX connectors:

Somemanufacturesuse5-pinXLRconnectorsfordatatransmissioninplaceof3-pin.5-pinXLRfixturesmaybeimplementedina3-pinXLRDMXline.Wheninsertingstandard5-pinXLRconnectorsintoa3-pinlineacableadaptormustbeused.Thediagrambelowdetailsthecorrectcableconversion.

Terminationreducessignaltransmissionproblemsandinterference.ItisalwaysadvisabletoconnectaDMXterminal,(resistance120Ohm1/4W)betweenpin2(DMX-)andpin3(DMX+)ofthelastfixture.

5-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)Pin 4: N/CPin 5: N/C

3-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)

3-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)

5-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)Pin 4: N/CPin 5: N/C

DMX setup

Page 10: 100W UV COB Flood · 100 U CO Flood User Manual 6 DMX mode: Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating

www.prolight.co.uk 100W UV COB Flood User Manual 10

WEEE notice

Correct Disposal of this Product (Waste Electrical & Electronic Equipment)

(Applicable in the European Union and other European countries with separate collection systems)

Thismarkingshownontheproductoritsliterature,indicatesthatitshouldnotbedisposedwithotherhouseholdwastesattheendofitsworkinglife.Topreventpossibleharmtotheenvironmentorhumanhealthfromuncontrolledwastedisposal,pleaseseparatethisfromothertypesofwastesandrecycleitresponsiblytopromotethesustainablereuseofmaterialresources.

Householdusersshouldcontacteithertheretailerwheretheypurchasedthisproduct,ortheirlocalgovernmentoffice,fordetailsofwhereandhowtheycantakethisitemforenvironmentallysaferecycling.

Businessusersshouldcontacttheirsupplierandcheckthetermsandconditionsofthepurchasecontract.Thisproductshouldnotbemixedwithothercommercialwastesfordisposal.

Page 11: 100W UV COB Flood · 100 U CO Flood User Manual 6 DMX mode: Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating

www.prolight.co.uk 100W UV COB Flood User Manual 11

Page 12: 100W UV COB Flood · 100 U CO Flood User Manual 6 DMX mode: Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating

www.prolight.co.uk 100W UV COB Flood User Manual 12