1000743 switch press 4-150psi 316ss st ┌─item text ...€¦ · 1000743 │switch press 4-150psi...

22
1000743 SWITCH PRESS 4-150PSI 316SS St ┌─Item Text ──────────────────────────────────────────────────────────────────┐ PRESSURE SWITCH, 4-150 PSI, 270 PSI MAX LINE PRESSURE, NEMA 4X ENCLOSURE, STYLE C EXTERNAL BELLOWS, 316SS BELLOWS, WITH 1/4" NPT FEMALE CONNECTION, SPDT CONTACTS, 5 AMPS @ 240V, 3 AMPS @ 600V, ALLEN-BRADLEY MODEL 836-C63S (MANUAL LITERATURE REQUIRED) └──────────────────────────────────────────────────────────────────────────────────┘

Upload: others

Post on 26-Sep-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 1000743 SWITCH PRESS 4-150PSI 316SS St ┌─Item Text ...€¦ · 1000743 │switch press 4-150psi 316ss │st ┌─item text ──────────────────────────────────────────────────────────────────┐

1000743 │SWITCH PRESS 4-150PSI 316SS │St ┌─Item Text ──────────────────────────────────────────────────────────────────┐ │ PRESSURE SWITCH, 4-150 PSI, │ │ 270 PSI MAX LINE PRESSURE, NEMA 4X ENCLOSURE, │ │ STYLE C EXTERNAL BELLOWS, 316SS BELLOWS, │ │ WITH 1/4" NPT FEMALE CONNECTION, │ │ SPDT CONTACTS, 5 AMPS @ 240V, 3 AMPS @ 600V, │ │ ALLEN-BRADLEY MODEL 836-C63S │ │ (MANUAL LITERATURE REQUIRED) │ └──────────────────────────────────────────────────────────────────────────────────┘

Page 2: 1000743 SWITCH PRESS 4-150PSI 316SS St ┌─Item Text ...€¦ · 1000743 │switch press 4-150psi 316ss │st ┌─item text ──────────────────────────────────────────────────────────────────┐
Page 3: 1000743 SWITCH PRESS 4-150PSI 316SS St ┌─Item Text ...€¦ · 1000743 │switch press 4-150psi 316ss │st ┌─item text ──────────────────────────────────────────────────────────────────┐

15-1

Bulletin 836

Pressure Controls15

UL and CSA Numbers — Page 15-15.

Conversion Factors — Page Important-2.

Enclosure Information — Page Important-8.

TABLE OF CONTENTSDescription Page Description PageProduct Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-2Technical Data

Technical Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-3Theory of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-4Applications for Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-4Control Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-5Repeat Accuracy and Mechanical Life . . . . . . . . . . . . . . . . . . . 15-5Standard Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-6Standard Contact Wiring Configurations . . . . . . . . . . . . . . . . . 15-6Special Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-6Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-6Factory Set Pressure Controls . . . . . . . . . . . . . . . . . . . . . . . . . 15-6Pressure Control Selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-6

Ordering InformationHow to Order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-7Catalog Number Explanation . . . . . . . . . . . . . . . . . . . . . . . . . . 15-7

Pressure ControlsStyle A — Internal Bellows — Copper Alloy . . . . . . . . . . . . . . . 15-8Style C — External Bellows — Copper Alloy . . . . . . . . . . . . . . 15-9Style C — External Bellows — Type 316 Stainless Steel . . . . 15-10

Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-11Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-13Factory Options

Factory Set Temperature Controls . . . . . . . . . . . . . . . . . . . . . 15-15Two Style A Controls in One Enclosure . . . . . . . . . . . . . . . . . 15-15

Refrigeration Controls. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-16Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-19

Bulletin 836 Style C Without Enclosure

Bulletin 836 Style A Without Enclosure

Self Lifting Pressure Plate Terminals withCombination Slotted/Phillips Head Screw

®®

Contact Block

Differential Cam(Shown at Minimum Differential)

Trip Indicating Scale — psi

Mounting Bracket

Nameplate With Pressure andElectrical Rating Information

Finger Safe Contact Block ShieldMeets IEC 529/IP2X & CSA

Clear Contact Inspection Cover

Trip Indicating Scale — Metric

Operating Range Adjustment Screw

Differential Adjustment Screw

External Bellows Connection

Differential Reference Scale

Page 4: 1000743 SWITCH PRESS 4-150PSI 316SS St ┌─Item Text ...€¦ · 1000743 │switch press 4-150psi 316ss │st ┌─item text ──────────────────────────────────────────────────────────────────┐

Bulletin 836

Pressure Controls

15-2

5

Product Overview

Description

Style A — Small Size, Internal Copper Alloy Bellows

Style C — Wider Ranges, External Bellows

Refrigeration Controls - See page 15-16

Note: psi = pounds per square inch gauge pressure

Style A• Independently adjustable range and differential• 7/16-20 SAE flare for 1/4" copper connection tubing• Adjustable Operating Range — 30" mercury vacuum…375 psi• Maximum Line Pressure — 750 psi• Occasional Surge Pressure — 850 psi

Style C• Independently adjustable range and differential• 1/4" N.P.T.F. female pipe connection• 3/8" N.P.S.F. female pipe connection (836-C1 and 836-C1A only)

Copper Alloy Bellows

• Adjustable Operating Range — 30" mercury vacuum…900 psi• Maximum Line Pressure — 1300 psi• Occasional Surge Pressure — 1600 psi

Type 316 Stainless Steel Bellows

• Adjustable Operating Range — 30" mercury vacuum…375 psi• Maximum Line Pressure — 650 psi• Occasional Surge Pressure — 650 psi

Style H• High Pressure Refrigeration Controls

Style L• Low Pressure Refrigeration Controls

Style P• High Pressure Definite Purpose Controls

Bulletin 836 Pressure Controls aredesigned for general industrial use tocontrol and detect pressure.Allen-Bradley Bulletin 836 PressureControls can be used in pneumatic andhydraulic systems. Pressure controls usecopper alloy or stainless steel bellows.The design and high quality componentsprovide long life operation with air, water,oil, non-corrosive liquids, vapors, gases,and some corrosive liquids or gases.Pressure controls feature snap actionprecision switches equipped with silvercontacts.Thestraight in-lineandrelativelyfriction-free construction providesaccurate and consistent operationregardless of the angle at which thecontrols are mounted. Pressure controlsare designed for easy adjustment of bothtrip and reset pressures.

Allen-Bradley Bulletin 836 PressureControls are used in many types ofindustries and applications. They can beused to control pneumatic systems,maintaining preset pressures betweentwovalues.Pressurecontrols canbe usedto detect over-pressures of gases orliquids to protect machines, processes,and personnel. They can also be used todetect low pressures to protect equipmentfrom loss of coolants and lubrication.Bulletin836 Pressure Controlsareofferedin a variety of styles to meet a wide rangeof applications. The devices are availablein Type 1, 4 & 13, 4X, 7 & 9 and 4 & 13combined and Open Type withoutenclosure for panel mounting. Pressurecontrols have a wide variety of contactmodifications to meet most control circuit

requirements. The controls haveadjustable pressure ranges from 30"mercury vacuum…900 psi withcorresponding differentials. Accessoriesand modifications are available to tailorthe device to meet most applicationrequirements.

Applications• Air Compressors• Compressed Air Monitor Systems• Liquid Level Control• Vacuum Transfer Systems• High Pressure Alert• Low Pressure Alert• Monitor Low and High Pressure

Page 5: 1000743 SWITCH PRESS 4-150PSI 316SS St ┌─Item Text ...€¦ · 1000743 │switch press 4-150psi 316ss │st ┌─item text ──────────────────────────────────────────────────────────────────┐

15-3

Bulletin 836

Pressure ControlsTechnical Data

Technical Terms

Figure 1Graphics to Illustrate Technical Terms

Adjustable Operating Range — Totalspan within which the contacts can beadjusted to trip and reset.Trip Setting — Higher pressure setting atwhich value the contacts transfer fromtheir normal state to a changed state.Reset Setting — Lower pressure settingat which value the contacts return to theirnormal state.Adjustable Differential — Differencebetween the trip and reset values.Minimum Differential — When thedifferential is set to the lowest pressuredifference between trip and reset.Maximum Differential — When thedifferential is set to the widest pressuredifference between trip and reset.Maximum Occasional SurgePressure – Maximum surge pressurethatcan be applied to the actuator. Surgesor transientscan occurduringstart-upandshut-down of a machine or system.Expressed in milliseconds, complexelectronic instrumentation is required tomeasure the varying amplitude,frequency, and duration of this wave form.Extreme surges that occur approximately8 times in a 24-hour period are negligible.

Maximum Line Pressure — Maximumsustained pressure that can be applied tothe bellows without permanent damage.The control should not be cycled at thispressure.Positive Pressure — Any pressure morethan 0 psi. See Figure 2.• Trip Setting — Increasing pressure

setting when contacts change state.• ResetSetting —Decreasingpressure

setting when contacts return to theirnormal state.

Vacuum (Negative) Pressure — Anypressure less than 0 psi, inches ofmercury vacuum. See Figure 3.• Trip Setting — Increasing vacuum

setting when contacts change state.• Reset Setting — Decreasing vacuum

setting when contacts return to theirnormal state.

psi — Devices listed are in gaugepressure units which use atmosphericpressure as a reference. Atmosphericpressure at sea level is approximately14.7 psi or 30" Hg.OperatingRangeAdjustmentScrew —This screw is used to adjust the trip settingby varying the force of the main spring.

Differential Adjustment Screw — Thisscrew is used to adjust reset setting byvarying the force of the differential bladespring.PressureMedia —There aremany typesof pressure media that are controlled.Examples include air, water, hydraulicfluids andother types of gases and liquids.The type of media and maximum systempressure will determine the type ofactuator used for the pressure controlapplication. See page 15-6.PressureConnection — Common typesof pressure connections used in controlsystems are 1/4" and 3/8" female pipethreads, and 7/16" — 20 SAE coppertubing.Contact Configuration — There aremany types of contact configurationsavailable. Bulletin 836 Style A and Cpressure controls offer a wide variety ofcontact configurations for both automaticoperation and manual reset. Seepage 15-11.

Trip Setting

Reset Setting

(Maximum Reset

(Minimum ResetAdjustment)

Adjustment)

75%

50%

25%

100%100% Operating Range

0 psi ReferenceVAC

Adju

stab

leO

pera

ting

Ran

ge

Max

imum

Line

Pres

sure

Incr

easi

ngPr

essu

reps

i

Adjustable SpanAd

just

able

Ope

ratin

gR

ange

MinimumDifferential

MaximumDifferential

Max

imum

Occ

asio

nal

Surg

ePr

essu

re

30" Vacuum Mercury Reference

C

B

A

Reset (Normal) State – B to C are closed.Trip State – B to A are closed.

Trip – on increasing pressure,contacts B to A open andcontacts B to C close.

Reset (Normal) State – B to A are closed.Trip State – B to C are closed.

C

B

A

Trip – on increasing pressure,contacts B to A open andcontacts B to C close.

Figure 3Vacuum Pressure

Figure 2Positive Pressure

Page 6: 1000743 SWITCH PRESS 4-150PSI 316SS St ┌─Item Text ...€¦ · 1000743 │switch press 4-150psi 316ss │st ┌─item text ──────────────────────────────────────────────────────────────────┐

Bulletin 836

Pressure Controls

15-4

5

Technical Data, Continued

Theory of Operation

Applications for ControlPressure controls can be used to either control or monitor a machine or process. Figure 5 shows a typical control application. Here,pressure is controlled within predetermined high and low values. Figure 6 shows a typical monitoring application. Here, pressure ismonitored between a high and low value, signaling when a preset limit has been exceeded.

Bulletin 836 Pressure Controls aredesigned to open or close electricalcircuits in response to changes inpneumatic (air or gas) or hydraulic (wateror oil) pressure. Figure 4 is a simplifieddrawing of a pressure control. Thesystem pressure is connected to thecontrol at the pressure connection. Thesystem pressure is applied directly intothe bellows. As pressure rises, thebellows exerts force on the main spring.When the threshold force of the mainspring is overcome, it transfers themotion to the contact block causing thecontacts to actuate — this is referred toas the Trip Setting. As pressuredecreases, the main spring will retract,causing the secondary differential bladespring to activate and return the contactsto their normal state - this is referred toas Reset Setting. Varying the force of themain spring (by turning the operatingrange adjustment screw) determineswhere the contacts will trip. Varying theforce of the secondary differential bladespring (by turning the differentialadjustment screw) determines where thecontacts will reset.

Figure 1Basic Mechanical Structure

Contact Block

Differential Blade Spring

Main Spring

Bellows Actuator

Pressure Connection

Trip

Differential

Reset

OutputContacts

ChangedState

NormalState

ChangedState

NormalState

Time

psi

or

Deg

rees

F

Trip

Differential

Reset

OutputContacts

ChangedState

NormalState

ChangedState

NormalState

Time

psi

or

Deg

rees

F

Figure 6Typical Monitoring Application

Figure 2Typical Control Application

Page 7: 1000743 SWITCH PRESS 4-150PSI 316SS St ┌─Item Text ...€¦ · 1000743 │switch press 4-150psi 316ss │st ┌─item text ──────────────────────────────────────────────────────────────────┐

15-5

Bulletin 836

Pressure ControlsTechnical Data, Continued

Control Settings

Repeat Accuracy and Mechanical Life

Figure 1Repeat Accuracy Versus Mechanical Life Graph

Allen-Bradley controls are designed forease of setting to help minimizeinstallation time. Standard controlsshipped from the factory are set at themaximum operating range andminimumdifferential. By following this simple two-step process, the control can be set tothe specific requirements for eachapplication. See Figure 7.

Step 1 — Adjust Trip SettingThe trip setting is set by turning theoperating range adjustment screw. Turnscrew counterclockwise to lower the tripsetting, or clockwise to raise the tripsetting. The approximate trip setting isshown on the indicating scale.Note: Turning the operating rangeadjustment screw will change both thetrip and reset settings in equalincrements.

Step 2 — Adjust Reset SettingThe reset setting is set by turning thedifferential adjustment screwcounterclockwise to increase thedifferential, or clockwise to decrease thedifferential.Note: Adjusting the differential does notaffect the trip setting.

Figure 1Trip and Reset Adjustment

Finger Safe Contact Block ShieldMeets IEC 529/IP2X & CSA

Terminal A

Clear ContactInspection Cover

Indicating Scale (psi)(Approximate Trip Setting)

Terminal B

Test Button (Optional)

Terminal C

Operating RangeAdjustment Screw

(Trip Pressure)

Indicating Scale (Metric)(ApproximateTrip Setting)

DifferentialAdjustment Screw(Reset Pressure)

Differential Reference Scale

The design and construction ofBulletin 836 Styles A and C controlsprovide a typical repeat accuracy of+ 0.5% or better. Repeat accuracy isbased on percent of maximum range,evaluated from test data and calculatedusing the formula per ICS 2-225standards.

Repeat accuracy and mechanical life ofbellows type controls is graphicallyillustrated in Figure 8. For generalapplications, controls selected where thecontacts operatebetween30…80%of theoperating range and where the maximumline and surge pressures do not exceedthe specified values will provide excellent

life and repeat accuracy. For morespecific applications, it is important tonotethat the controls are designed to operatebelow or above these values. However,there may be a small trade-off betweenthe factors of repeat accuracy andmechanical life.

75%

50%

25%

100%

Adju

stab

leO

pera

ting

Ran

ge

0 psi Reference

VAC

Adju

stab

leO

pera

ting

Ran

ge

Incr

easi

ngPr

essu

reps

i

30" Vacuum Mercury Reference

80%

30%

RecommendedSelection Rangefor GeneralApplications

Usable area of range that provides best repeat accu-racy and possible slightly decreased operating life.

Usable area of range that provides longest lifeand possible slightly reduced repeat accuracy.

Life(BellowsControls

Only)

RepeatAccuracy(Bellows

and PistonControls)

Improved Life/Accuracy

Page 8: 1000743 SWITCH PRESS 4-150PSI 316SS St ┌─Item Text ...€¦ · 1000743 │switch press 4-150psi 316ss │st ┌─item text ──────────────────────────────────────────────────────────────────┐

Bulletin 836

Pressure Controls

15-6

5

Technical Data, Continued

Standard Contacts

Note: NEMA does not rate contacts to switch low voltage and current.Bulletin 836 Styles A and C Pressure Controls are supplied with silver contacts. The devices are designed to deliver high force snapaction to the contacts. This provides exceptional contact fidelity at 24V DC I/O card current level entry when the control is protectedin a suitable enclosure for the surrounding environment.

Pressure Control SelectionThe selection table below is an overview of the three types of Bulletin 836 Pressure Controls Allen-Bradley offers. Each type ofcontrol is suitable for use on many types of applications. Pressure ranges, pressure connections, enclosure types and thecompatibility of the actuator with different types of pressure media are given to assist in the selection of which type of control to use.

➊ Corrosive liquids and gases compatible with Type 316 Stainless Steel.

Snap-Action Contact OperationContact blocks are single-pole, double-throw and can be wired to open or closeon increasing or decreasing pressures.

Non-Inductive Ratings5 A, 240V3 A, 600V

Control Circuit RatingsAC - 125 VA, 24…600VDC - 57.5 VA, 115…230V

Standard Contact Wiring Configurations

836 Style A 836 Style C 836 Style C

Actuator TypeInternal Bellows,

Copper AlloyExternal Bellows,

Copper AlloyExternal Bellows,

Stainless Steel Type 316Adjustable Operating Ranges 30" Hg Vacuum to 375 psi 30" Hg Vacuum to 900 psi 30" Hg Vacuum to 375 psiAdjustable Differentials 2 to 95 psi 0.2 to 125 psi 0.4 to 80 psiMaximum Line Pressures 750 psi 1300 psi 650 psiOccasional Surge Pressures 850 psi 1600 psi 650 psi

Pressure MediaAir ● ● ●

Water ● ● ●

Hydraulic Fluids ● ● ●

Liquids:Corrosive ➊

Non-Corrosive ● ● ●

Gases:Corrosive ➊

Non-Corrosive ● ● ●

EnclosuresOpen Type ● ● ●

Type 1 ● ● ●

Type 4 & 13 ● ● ●

Type 4X ● ●

Type 7 & 9 and 4 & 13 ● ● ●

Pipe Connections

Pressure Connection7/16"-20 SAE Flare for 1/4"

Copper Tubing

1/4" N.P.T.F. Female Pipe Thread or3/8" N.P.S.F. Female Pipe connection

(836-C1 and 836-C1A only)

1/4" N.P.T.F.Female Pipe Thread

Single Pole Double Throw

C

B

A

Positive Pressure Vacuum Pressure

C

B

A

Special ControlsA large number of unlisted catalogmodifications and complete devices areavailable for specific and OEMapplications.Special controls and modification serviceis available to meet many applicationsunique to the OEM market.Consult your nearest Allen-Bradley SalesOffice for assistance with specificmodified controls and accessories.

Temperature RangeTemperature range at +32° F (0°C) orbelow is based on the absence of freezingmoisture, water, or other fluids that maysolidify and impede operation of thecontrol. Temperature ratings are asfollows:Operating: –22… +150°F

(–30…+66°C)Storage: –22…+200°F

(–30…+93°C)

Factory-Set Pressure ControlsAllen-Bradley will factory set pressurecontrols to customer-specified values.See Factory Options, page 15-15.

Page 9: 1000743 SWITCH PRESS 4-150PSI 316SS St ┌─Item Text ...€¦ · 1000743 │switch press 4-150psi 316ss │st ┌─item text ──────────────────────────────────────────────────────────────────┐

15-7

Bulletin 836

Pressure ControlsOrdering Information

Ordering Bulletin 836 Pressure Controls

How to Order

Catalog Number ExplanationNote: Catalog numbers must not include blank spaces.

Conversion Factors

Step 1: Basic DeviceSelect a catalog number for the basic device. . . . . . . . . . . . See pages 15-8…15-9.

Step 2: ModificationsIf required, add the appropriate modificationsuffix code(s) to the catalog number of the basic device. . . . See page 15-11 and 15-12.

Step 3: AccessoriesIf required, select appropriate accessories. . . . . . . . . . . . . . See page 15-13 and 15-14.

Step 4: Factory OptionsFactory-Set Pressure Controls.. . . . . . . . . . . . . . . . . . . . . . . See page 15-15.

Conversion Factors (Rounded)

psi x 703.1 = mm/H2Opsi x 27.68 = in. H2Opsi x 51.71 = mm/Hgpsi x 2.036 = in. Hgpsi x 0.0703 = kg/cm2

psi x 0.0689 = barpsi x 68.95 = mbarpsi x 6895 = Papsi x 6.895 = kPa

Note:psi — pounds per square inch (gauge)H2O at 39.2°F/Hg at 32°F

When ordering Bulletin 836 Pressure Controls, consider the following:

• Device Style• Adjustable Operating Range• Adjustable Differential• Maximum Line Pressure

• Occasional Surge Pressure• Pressure Media• Enclosure Type• Pressure Connection

836 – A 1 A X9

Style of Device:A=Internal BellowsC=External Bellows

Pressure Specifications:Adjustable Operating RangeAdjustable DifferentialMaximum Line PressureMax. Occasional Surge PressureSee Specifications Tables

Letter = Enclosure Type:A = Type 1E = Type 7 & 9 and 4 & 13 Combined

Metallic (Aluminum)J = Type 4 & 13 Metallic (Aluminum)S = Type 4X Non-MetallicNone = Without Enclosure

Modification to basic deviceselected from Modifications table.Add suffix codes in descending order.(Optional. See pages 15-11 and 15-12.)

Bulletin Number

Page 10: 1000743 SWITCH PRESS 4-150PSI 316SS St ┌─Item Text ...€¦ · 1000743 │switch press 4-150psi 316ss │st ┌─item text ──────────────────────────────────────────────────────────────────┐

Bulletin 836

Pressure Controls

15-8

5

Style A Internal Bellows — Copper Alloy

Style A Internal Bellows —Copper Alloy Bellows ➊➊➊➊ With 7/16" — 20 SAE Flare for 1/4" Copper Tubing Connection

Style A Internal Bellows —Copper Alloy Bellows ➊➊➊➊ With 7/16" — 20 SAE Flare for 1/4" Copper Tubing Connection

➊ Copper alloy bellows may be used on water or air, and other liquids or gases not corrosive to this alloy.➋ For applications where settings approach 0 psi, select a control that has an adjustable range that goes into vacuum.➌ Transients (pulses) can occur in a system prior to reaching a steady-state condition. Surge pressures within published values generated during

start-up or shut-down of a machine or system, not exceeding 8 times in a 24 hour period, are negligible.➍ To determine differential in inches of mercury vacuum multiply value in table by 2.036 (or approximately 2).➎ The combined Type 7 & 9 and 4 & 13 Hazardous Gas and Dust service enclosure is supplied with special gasket and O-ring seal to diminish/

exclude moisture, fluids, and dust from entering the enclosure. Enclosures rated 7 & 9 only are not designed to restrict moisture from enteringthe enclosure, which is common to outdoor service.

Pressure Specifications Enclosure Type

AdjustableOperating Range

Hg Vacuum to psi ➋

AdjustableDifferential psi(Approximate

Mid-Range Values)

Maximum psiOpen Type

Without EnclosureType 1

LinePressure

OccasionalSurge

Pressure ➌

Cat. No. Cat. No.

30" Vacuum…756…140

12…25016…375

2…20 ➍

3…356…658…95

160280500750

160340600850

836-A1836-A2836-A3836-A4

836-A1A836-A2A836-A3A836-A4A

Pressure Specifications Enclosure Type

AdjustableOperating Range

Hg Vacuum to psi ➋

AdjustableDifferential psi(Approximate

Mid-Range Values)

Maximum psi Type 4 & 13 Type 7 & 9 and 4 & 13 ➎

LinePressure

OccasionalSurge

Pressure ➌

Cat. No. Cat. No.

30" Vacuum…756…140

12…25016…375

2…203…356…658…95

160280500750

160340600850

836-A1J836-A2J836-A3J836-A4J

836-A1E836-A2E836-A3E836-A4E

Style A Internal Bellows —Copper Alloy, Type 1

Style A Internal Bellows —Copper Alloy, Type 4 & 13

Page 11: 1000743 SWITCH PRESS 4-150PSI 316SS St ┌─Item Text ...€¦ · 1000743 │switch press 4-150psi 316ss │st ┌─item text ──────────────────────────────────────────────────────────────────┐

15-9

Bulletin 836

Pressure ControlsStyle C External Bellows — Copper Alloy

Style C External Bellows —Copper Alloy Bellows ➊➊➊➊ With 1/4" N.P.T.F. Female Pipe Connection

Style C External Bellows —Copper Alloy Bellows ➊➊➊➊ With 1/4" N.P.T.F. Female Pipe Connection

➊ Copper alloy bellows may be used on water or air, and other liquids or gases not corrosive to this alloy.➋ For applications where settings approach 0 psi, select a control that has an adjustable range that goes into vacuum.➌ Transients (pulses) can occur in a system prior to reaching a steady-state condition. Surge pressures within published values generated during

start-up or shut-down of a machine or system, not exceeding 8 times in a 24 hour period, are negligible.➍ With 3/8" N.P.S.F. female pipe connection.➎ To determine differential in inches of mercury vacuum multiply value in table by 2.036 (or approximately 2).➏ The combined Type 7 & 9 and 4 & 13 Hazardous Gas and Dust service enclosure is supplied with special gasket and O-ring seal to diminish/

exclude moisture, fluids, and dust from entering the enclosure. Enclosures rated 7 & 9 only are not designed to restrict moisture from enteringthe enclosure, which is common to outdoor service.

Pressure Specifications Enclosure Type

AdjustableOperating Range

Hg Vacuum to psi ➋

Adjustable Differentialpsi (Approximate

Mid-Range Values)

Maximum psiOpen Type

Without EnclosureType 1 Type 4 & 13

LinePressure

OccasionalSurge

Pressure ➌

Cat. No. Cat. No. Cat. No.

12" Vacuum…8 ➍

30" Vacuum…100.8…30

30" Vacuum…452…80

30" Vacuum…1004…1506…25035…37550…50050…650

200…900

0.2…2.50.4…60.4…61…121…122…252…254…456…80

12…11516…12525…125

256580

175190300300500900

130013001300

307580190210375375650

1200160016001600

836-C1836-C2836-C3836-C4836-C5836-C6836-C7836-C8836-C9

836-C10836-C11836-C12

836-C1A836-C2A836-C3A836-C4A836-C5A836-C6A836-C7A836-C8A836-C9A

836-C10A836-C11A836-C12A

—836-C2J836-C3J836-C4J836-C5J836-C6J836-C7J836-C8J836-C9J

836-C10J836-C11J836-C12J

Pressure Specifications Enclosure Type

AdjustableOperating Range

Hg Vacuum to psi ➋

Adjustable Differential psi(Approximate

Mid-Range Values)

Maximum psi Type 4X Type 7 & 9 and 4 & 13 ➏

LinePressure

OccasionalSurge

Pressure ➌

Cat. No. Cat. No.

12" Vacuum…8 ➍

30" Vacuum…100.8…30

30" Vacuum…452…80

30" Vacuum…1004…1506…250

35…37550…50050…650200…900

0.2…2.5 ➎

0.4…6 ➎

0.4…61…12 ➎

1…122…25 ➎

2…254…456…80

12…11516…12525…125

256580

175190300300500900130013001300

307580

1902103753756501200160016001600

—836-C2S836-C3S836-C4S836-C5S836-C6S836-C7S836-C8S836-C9S

836-C10S836-C11S836-C12S

—836-C2E836-C3E836-C4E836-C5E836-C6E836-C7E836-C8E836-C9E

836-C10E836-C11E836-C12E

Style C External Bellows —Copper Alloy, Type 1 With Pilot Light Option

Style C External Bellows —Copper Alloy, Type 4 & 13

Page 12: 1000743 SWITCH PRESS 4-150PSI 316SS St ┌─Item Text ...€¦ · 1000743 │switch press 4-150psi 316ss │st ┌─item text ──────────────────────────────────────────────────────────────────┐

Bulletin 836

Pressure Controls

15-10

5

Style C External Bellows — Type 316 Stainless Steel

Style C External Bellows —Type 316 Stainless Steel Bellows ➊➊➊➊ With 1/4" N.P.T.F. Female Pipe Connection

➊ Type 316 stainless steel bellows are available for more corrosive liquids or gases.➋ For applications where settings approach 0 psi, select a control that has an adjustable range that goes into vacuum.➌ Transients (pulses) can occur in a system prior to reaching a steady-state condition. Surge pressures within published values generated during

start-up or shut-down of a machine or system, not exceeding 8 times in a 24 hour period, are negligible.➍ To determine differential in inches of mercury vacuum multiply value in table by 2.036 (or approximately 2).➎ The combined Type 7 & 9 and 4 & 13 Hazardous Gas and Dust service enclosure is supplied with special gasket and O-ring seal to diminish/

exclude moisture, fluids, and dust from entering the enclosure. Enclosures rated 7 & 9 only are not designed to restrict moisture from enteringthe enclosure, which is common to outdoor service.

Pressure Specifications Enclosure Type

AdjustableOperating Range

Hg Vacuum to psi ➋

AdjustableDifferential psi(Approximate

Mid-Range Values)

Maximum psiOpen Type

WithoutEnclosure

Type 1 Type 4 & 13 Type 4XType 7 & 9

and 4 & 13 ➎

LinePressure

OccasionalSurge

Pressure ➌

Cat. No. Cat. No. Cat. No. Cat. No. Cat. No.

30" Vacuum…100.8…30

30" Vacuum…1004…1506…250

35…375

0.4…6 ➍

0.4…62…25 ➍

2…254…458…80

6565

270270450650

6565

270270450650

836-C60836-C61836-C62836-C63836-C64836-C65

836-C60A836-C61A836-C62A836-C63A836-C64A836-C65A

836-C60J836-C61J836-C62J836-C63J836-C64J836-C65J

836-C60S836-C61S836-C62S836-C63S836-C64S836-C65S

836-C60E836-C61E836-C62E836-C63E836-C64E836-C65E

Style C External Bellows —Type 4X Glass Polyester Enclosure

Style C External Bellows —Stainless Steel, Type 7 & 9 and 4 & 13 Combined

Page 13: 1000743 SWITCH PRESS 4-150PSI 316SS St ┌─Item Text ...€¦ · 1000743 │switch press 4-150psi 316ss │st ┌─item text ──────────────────────────────────────────────────────────────────┐

15-11

Bulletin 836

Pressure ControlsModifications

Ordering ModificationsModifications are ordered by adding the appropriate modification suffix code to the catalog number of the basic device. Add suffixcodes to the catalog number in descending order (highest number first).

ModificationsContact Blocks ➊ — Trip pressure-indicating scales are supplied on controls with standard contact block.

➊ Contact blocks not available for field conversion or replacement.➋ Minimum specified differential value approximately doubles.➌ Manual reset devices cannot be supplied with an adjustable differential. Inherent differential is approximately three times the differential

of the corresponding adjustable differential control.➍ Available only for replacement of complete open type control in an existing Type 1 or 4 & 13 enclosure. Replacement in a Type 7 & 9 enclosure

is not available because it would void UL and CSA.➎ Type 7 & 9 enclosures for manual reset devices are not also rated Type 4 & 13.

Note: NEMA does not rate contacts to switch low voltage and current. Bulletin 836 Styles A and C Pressure Controls are suppliedwith silver contacts. The devices are designed to deliver high force snap action to the contacts. This provides exceptional contactfidelity at 24V DC I/O card current level entry when the control is protected in a suitable enclosure for the surrounding environment.

Description Rating SymbolSuffixCode

Automatic Operation

Standard Contact Block — Single-pole, single-throw, snap-action.Supplied when a contact block suffix is not added to the catalognumber.

Control Circuit Rating: SeeSpecifications on page 15-6

Single-pole double throw — slow acting contact with no snap action.Contacts close on rise and close on fall with an open circuit betweencontact closures.

Control Circuit Rating:AC-125VA, 24…250V

X171 ➋

Single pole single throw, normallyopen — closes on rise.

0.5 HP, 115V AC1 HP, 230V AC

Control Circuit Rating:AC-125 VA, 24…110VAC-345 VA, 110…600VDC-57.5 VA, 110…250V

X221 ➋

Single pole single throw, normally closed — opens on rise. X231 ➋

Single pole single throw, normallyopen — closes on rise.

1 HP, 115V AC1.5 HP, 230V AC

Control Circuit Rating:AC-600 VA, 110…600VDC-57.5 VA, 110…250V

X321 ➋

Single pole single throw, normally closed — opens on rise. X331 ➋

Two circuit, single pole single throw, normally open — a commonterminal is connected to two separate contacts which close on rise.

Non-inductive:5 A, 240V…3 A, 600VControl Circuit Rating:AC-125 VA, 24…600V

DC-57.5 VA, 115…230V

X021 ➋

Two circuit, single pole single throw, normally closed — a commonterminal is connected to two separate contacts which open on rise.

X031 ➋

External Manual Reset (Not available in Type 7 & 9 Enclosures) ➌➍

Single pole single throw, normallyopen — contacts open at a predetermined setting on fall and remainopen until system is restored to normal run conditions at which timecontacts can be manually reset.

Non-inductive:5 A, 240V3 A, 600V

Control Circuit Rating:AC-125 VA, 24…600V

DC-57.5 VA, 115…230V

X140 ➌➍➎

Single pole single throw, normally closed — contacts open on riseand remain open until system is restored to normal run conditionsat which time contacts can be manually reset.

X150 ➌➍➎

Single pole double throw, one contact normally closed — contactopens on rise and remains open until system is restored to normalrun condition at which time contact can be manually reset. A secondcontact closes when the first contact opens.

X15A ➌➍➎

Page 14: 1000743 SWITCH PRESS 4-150PSI 316SS St ┌─Item Text ...€¦ · 1000743 │switch press 4-150psi 316ss │st ┌─item text ──────────────────────────────────────────────────────────────────┐

Bulletin 836

Pressure Controls

15-12

5

Modifications, Continued

Ordering Modifications (cont’d)Modifications are ordered by adding the appropriate modification suffix code to the catalog number of the basic device. Add suffixcodes to the catalog number in descending order (highest number first).

Modifications

➊ Not available on combined Type 7 & 9 and 4 & 13, Type 4X, and manual reset devices.

Modification Description Suffix Code

Oxygen/Nitrous Oxide ServiceBellows and fittings are specially prepared for oxygen and nitrous oxide service. Thedevices are tested with pure oxygen, bellows are plugged for protection fromcontamination, and a tag warning against contamination is applied.

X2

Tamper Resistant Adjustment

Range and differential adjustment screws are designed so that after a setting has beenapplied to the control, the adjustment screws can be broken off with a pliers. Note: The“break-off” adjustment screw(s) will not be broken off unless a factory setting is given andthe order specifies “Break-off Adjustment Screw(s)”. See paragraph entitled “FactorySet Pressure Controls” on page 15-15.

X4

Neon Pilot Light 120V ACA high intensity neon pilot light is available for 120V AC, 60 Hz applications and can bewired for ON or OFF operation. The current rating is 1.0 mA. ➊

X9

Red LED Pilot Light 24V DCA high intensity LED 24V DC pilot light is available to meet the requirements of theautomotive, machine tool builders and other industries. The current rating is 22 mA andcan be wired for ON or OFF operation. ➊

X15

Green LED Pilot Light 24V DCA high intensity LED 24V DC pilot light is available to meet the requirements of theautomotive, machine tool builders and other industries. The current rating is 22 mA andcan be wired for ON or OFF operation. ➊

X18

5-Pin Mini-Type Receptacle —No Pilot Light

Supplied with Receptacle ready for field wiring. X42

5-Pin Mini-Type Receptacle —With Pilot Light

Supplied with receptacle and pilot light ready for field wiring. Pilot light Suffix Code X9(120V AC Neon) or Suffix Code X15 or X18 (24V DC LED) must also be specified. SeeSuffix Codes X9, X15 or X18 description above.

X43

5-Pin Micro-Type Receptacle —No Pilot Light

Supplied with receptacle ready for field wiring. X142

5-Pin Micro-Type Receptacle —With Pilot Light

Supplied with Receptacle and Pilot Light ready for field wiring. Pilot Light Suffix Code X9(120V AC Neon) or Suffix Code X15 or X18 (24V DC LED) must also be specified. SeeSuffix Codes X9, X15 or X18 description above.

X143

Manual Test Button —Standard Contact Block

Allows electrical testing of circuit - positive pressure setting only. Normally Closed contact(A-B) opens. Normally Open contact (B-C) closes. See photo page 15-5 and Suffix CodesX221 and X321.

X47

Page 15: 1000743 SWITCH PRESS 4-150PSI 316SS St ┌─Item Text ...€¦ · 1000743 │switch press 4-150psi 316ss │st ┌─item text ──────────────────────────────────────────────────────────────────┐

15-13

Bulletin 836

Pressure ControlsAccessories

Ordering AccessoriesAccessories are ordered as separate catalog numbers. Select the required accessories from the tables below.

Accessories

Pipe Adapter

Contact Block Replacement Kit

Hardware Kits for Mounting Open Type Controls in Special Enclosures

Angle Mounting Brackets

Steam and/or Corrosive Media Applications — Isolation Traps

Description Cat. No.

1/4" male pipe adapter with copper seating washer for Style A only. 836-N1

Description Cat. No.

Kit consists of a standard contact block and instructions. 836-N2

Description Type Material Cat. No.

Hardware kits for mounting open type controls in special enclosures allow easeof connecting pressure lines to the enclosure. For use with Type 1 and Type 4& 13 enclosures with wall thickness up to 0.25" (6.35 mm).

Style A Controls

Open Type Controls Plated Steel 836-N5

Style C Controls

Open Type ControlsBrass 836-N8

Stainless Steel 836-N10

Description Bracket Type Cat. No.

For mounting one or two open type Bulletin 836 Style A Pressure Controls on an enclosure mountingplate.

Single Bracket 836-N11

Dual MountingBracket

836-N12

Description Type Cat. No.

An isolation trap is available for high temperature media applications above 150°F and corrosiveapplications compatible with Type 316 stainless steel tubing and fittings. The isolation coil is insertedbetween the bellows of the pressure control and the elevated temperature line of the system. The isolationtrap will fill with condensed water or can be filled with water or suitable fluid when installed. A siliconebuffer fluid is available in a convenient dispenser. Copper alloy lower and higher pressure range bellowscan be applied to many applications using the isolation trap. The silicone buffer fluid is used to isolatemany corrosive substances from coming in contact with the bellows. The isolation trap is rated at 3000psi working pressure.

Isolation Trap WithTwo 1/4" Male Pipe

Fittings836-N25

Isolation Trap WithOne 1/4" Male andOne 1/4" Female

Pipe Fitting

836-N26

Two Ounces ofBuffer Fluid to Fill

Bellows and Tubing836-N27

Isolation Trap and Silicone Buffer Fluid

Page 16: 1000743 SWITCH PRESS 4-150PSI 316SS St ┌─Item Text ...€¦ · 1000743 │switch press 4-150psi 316ss │st ┌─item text ──────────────────────────────────────────────────────────────────┐

Bulletin 836

Pressure Controls

15-14

5

Accessories, Continued

Ordering Accessories (cont'd)Accessories are ordered as separate catalog numbers. Select the required accessories from the tables below.

Accessories

External Fixed Pulsation Snubbers

Selectable Element Pulsation Snubbers

Selectable Pulsation Snubber Porosity Elements

➊ SSU Saybolt Seconds Universal — units of viscosity measurement.

Note: Color code is located on end of element.

Pulsation Snubbers

Description Type Cat. No.

Controls are supplied as standard with an internal pulsation snubber. However, a control properly selectedand used within the adjustable range values yet having a short bellows life is a good indication of thepresence of extreme surge pressures. External fixed pulsation snubbers are available to provideadditional dampening when extreme pulsations or surges are present.

Snubber forStyle A Controls

836-N6

Snubber forStyle C Controls

836-N7

Description Type Cat. No.

Controls are supplied as standard with an internal pulsation snubber. However, a control properly selectedand used within the adjustable range values yet having a short bellows life is a good indication of thepresence of extreme surge pressures. Selectable element pulsation snubbers are supplied with fivedifferent elements to provide a selectable balance between maximizing pressure control life andminimizing control response time. Pulsation snubbers are supplied with the mid-range element alreadymounted and four other color-coded porosity elements included in the package. See the SelectablePulsation Snubber Porosity Elements table below for porosity specifications.

Snubber forStyle C Controls

836-N40

Description Recommended Type of Service Color Code Porosity Cat. No.

Package consists of five porosity elements andcomplete instructions. Elements are color-coded foreasy identification. Elements are available in fivedifferent porosities for a wide range of applications.

Viscous fluids (over 500 SSU) ➊ None Coarser 836-N43

Medium type oils (225…500 SSU) ➊ Black 836-N44

Water and light oils (30… 225 SSU) ➊ Brown 836-N45

Low viscosity fluids (under 30 SSU) ➊ Green 836-N46

Air and other gases Red Finer 836-N47

One (1) of each of the above — Assorted 836-N48

Fixed Pulsation SnubbersMale/Female Pipe Threads

Selectable Element Pulsation SnubbersMale/Female Threads

Porosity Elements

Pulsation Snubbers

Page 17: 1000743 SWITCH PRESS 4-150PSI 316SS St ┌─Item Text ...€¦ · 1000743 │switch press 4-150psi 316ss │st ┌─item text ──────────────────────────────────────────────────────────────────┐

15-15

Bulletin 836

Pressure ControlsFactory Options

Factory Options

➊ Specify psi (pounds per square inch) or, in Hg Vacuum (inches of mercury vacuum).➋ Per ANSI B40.1 Grade 2A (0.5% accuracy full scale), Grade 3A (0.25% accuracy full scale), etc.

File and Guide Numbers

Bulletin 836

UL CSA

File Number Guide Number File Number Class

E14842E53048 (Haz. Loc.)

(NKPZ2)NKPZNOWT

LR1234LR11924 (Haz. Loc.)

1222-013211-033218-02

Hazardous Location Enclosure not CE compliant.

Factory Set Pressure ControlsOrdering Factory-Set PressureControls.• When a specific differential is

unimportant, and the approximateinherent minimum differential satisfiesthe application, specify the factorysetting as follows:

–OR–

• When a specific differential is required,specify factory settings as follows:

Quality analog “Test” ➋ gauges are usedwhen applying requested factory settingsto these rugged industrial grade pressurecontrols. (Gauges are calibrated and theaccuracy is traceable to National Bureauof Standards.) The actual requestedsetting is applied to the control by readingthe set point directly from the test gaugebeing used. However, traceable gaugetolerance variance between source anduser, and possible severe shock duringshipping and installation, may contributeto the factory settings deviating slightlyfrom the specified values. Slightrecalibration can easily be accomplishedupon final installation to meet specificrequirements for the more demandingapplications. When installed, the controlswill perform with a repeat accuracy asestablished in the paragraph on page15-5 entitled “Repeat Accuracy andMechanical Life”. Special service isavailable to factory set controls on DigitalLaboratory Instruments, up to 600 psi,when required for the more criticalapplications. An additional charge may beadded for this service contingent uponsetting tolerance and quantity. Consultyour nearest Allen-Bradley Sales Office.

Two Style A Controls In One EnclosureBulletin 836 Style pressure controls whichfunction independently may be mountedside by side in a single Type 1 enclosure.This design is ideal for installations wheretwo controls would ordinarily be mounted.Each dual unit can be a combination of aStyle A pressure control and a bulb andcapillary type temperature control. Seerespective product tables.Toorder this arrangement,specify the twodesired catalog numbers in their mountedposition within the dual enclosure to forma single catalog number. The list price isthe sum of the two Type 1 encloseddevices.For more information on special controls,consult your nearest Allen-Bradley SalesOffice.

Ref: Set to open at ➊ increasingpressure. Minimum differential.

Ref: Set to close at ➊ decreasingpressure. Minimum differential.

Ref: Set to open at ➊ .Close at ➊ .

Page 18: 1000743 SWITCH PRESS 4-150PSI 316SS St ┌─Item Text ...€¦ · 1000743 │switch press 4-150psi 316ss │st ┌─item text ──────────────────────────────────────────────────────────────────┐

Bulletin 836

Pressure Controls

15-16

5

Product Overview

Refrigeration Controls

Description

Style H — High Pressure Refrigeration Controls

Style L — Low Pressure Refrigeration Controls

Style P — High Pressure Definite Purpose Refrigeration Controls

Style H• Copper alloy bellows with built-in pulsation snubber• 7/16" — 20 SAE male thread for 45 degree flare fitting• Adjustable Operating Range — 30…120 psi• Maximum Line Pressure — 450 psi• Occasional Surge Pressure — 800 psi• With capillary and flare connection

Style L• Copper alloy bellows with built-in pulsation snubber• With capillary and tubing connection• Adjustable Operating Range — 20" Hg Vacuum…120 psi• Maximum Line Pressure — 220 psi

Style P• Copper alloy bellows with built-in pulsation snubber• 7/16" — 20 SAE male thread for 45 degree flare fitting• Operating Range — 30…700 psi• Line and Occasional Surge Pressure — 800 psi• Fixed Differential — 30 psi

Bulletin 836 Refrigeration Controls aresimilar to Bulletin 836 Style A PressureControls. However, refrigeration controlsare constructed with additional pulsationdampening to filter out the severepulsations generated by reciprocatingrefrigeration compressors. Pressurecontrols not supplied with the addedsnubber function may result in reducedbellows life. The reduced life results frompulsations severe enough to cause thebellows to squeal at the pump frequencyor at the harmonic wave generated at

specific pump loading demands.Refrigeration controls are supplied asstandard with the pulsation snubber builtinto the stem of the bellows.Allen-Bradley heavy duty refrigerationcontrols have copper alloy bellows for usewith non-corrosive refrigerants. Thedevices can be supplied as single OpenType devices or mounted in a Type 1enclosure. Standard controls have7/16" – 20 SAE male threads for a45 degree flare fuel and lubricant fitting.Optionally, the refrigeration controls can

be supplied with capillary tubing. Thecapillary terminates with 1/4" N.P.T.F.tubing which is flared and supplied with afemale nut. To modify the standardpressure connection, add suffix “-36”(denotes 36") to the catalog number.There is no price addition for changing toa capillary type pressure connection.Example: Cat. No. 836-H11-XHC,modified for a 36" capillary connection, isCat. No. 836-H11-XHC-36.

Page 19: 1000743 SWITCH PRESS 4-150PSI 316SS St ┌─Item Text ...€¦ · 1000743 │switch press 4-150psi 316ss │st ┌─item text ──────────────────────────────────────────────────────────────────┐

15-17

Bulletin 836

Pressure ControlsStyle H, L and P Refrigeration Controls — Copper Alloy Bellows

Style H High Pressure — Copper Alloy Bellows ➊➊➊➊

Style L Low Pressure — Copper Alloy Bellows ➊➊➊➊

Style P High Pressure Definite Purpose — Copper Alloy Bellows ➊➊➊➊

Contact Reference Number Table

➊ Copper alloy bellows may be used on water or air, and other liquids or gases not corrosive to this alloy.➋ To determine differential in inches of mercury vacuum multiply value in table by 2.036 (or approximately 2).

Pressure Specifications Enclosure TypeContact

ReferenceNumber (Seetable below)

AdjustableOperatingRange psi

AdjustableDifferential psi

(Approximate Mid-Range Values)

Maximum LinePressure psi

LimitedMaximum Stop

psi

Open TypeWithout Enclosure

Type 1

Cat. No. Cat. No.

30…27050…450100…285200…425125…280

30…8040…10040…9040…90

60…120

600800600800800

——

285425280

836-H11-XHCS836-H11-BLCS836-H33-XKKS836-H33-BLKS836-H33-BKKS

836-H11-XHC836-H11-BLC836-H33-XKK836-H33-BLK836-H33-BKK

11333

Customer Specified, Factory Locked Operating Range With Fixed Differential of 30 psi

75…350 35 800 — 836-H33-XNAS 836-H33-XNA 3

Pressure Specifications Enclosure Type ContactReference

Number (Seetable below)

Adjustable OperatingRange

Hg Vacuum to psi

Adjustable Differentialpsi (Approximate

Mid-Range Values)

Maximum LinePressure psi

Open Type WithoutEnclosure

Type 1

Cat. No. Cat. No.

20" Hg Vacuum…120 psi20" Hg Vacuum…120 psi

5…30 ➋

9…50 ➋

220220

836-AL11-NKCS836-AL32-NKCHS

836-AL11-NKC836-AL32-NKCH

12

Pressure Specifications Enclosure Type

AdjustableOperatingRange psi

FixedDifferential psi

Maximum LinePressure psi

LimitedMaximum Stop

psi

Open Type WithoutEnclosure

Type 1Contact

ReferenceNumber (Seetable below)Cat. No. Cat. No.

30…700 30 800 — 836-P11-ARBS 836-P11-ARB 1

Reference Number Description Symbol Rating

1Single pole double throw — automatically opens orcloses on rise or fall.

Non-inductive:5 A, 240V … 3 A, 600VControl Circuit Rating:AC-125VA, 24…600V

DC-57.5VA, 115…230V

2 Single pole single throw, normally open — closes on rise. 1 HP, 115V AC1.5 HP, 230V AC

Control Circuit Rating:AC-600 VA, 110…600VDC-57.5 VA, 110…250V3

Single pole single throw, normally closed — opens onrise.

Style H High Pressure —Copper Alloy, Open Type With Capillary

Adjustable Differential

Style L Low Pressure —Copper Alloy, Open Type

Adjustable Differential

Style P High Pressure —Copper Alloy, Open Type With Capillary

Fixed Differential

Page 20: 1000743 SWITCH PRESS 4-150PSI 316SS St ┌─Item Text ...€¦ · 1000743 │switch press 4-150psi 316ss │st ┌─item text ──────────────────────────────────────────────────────────────────┐

Bulletin 836

Pressure Controls

15-18

5

Factory Options

Factory Options for Refrigeration Controls

Two Controls In One EnclosureIt is common in the industry to supply a low pressure Style L and a high pressure Style H mounted in a common, dual Type 1enclosure. This factory option can be supplied with the low pressure control on the left and the high pressure control on the right.To order, combine the two desired Type 1 catalog numbers into a single number. Example: Low pressure control 836-AL11-NKC-36, plus high pressure control 836-H11-BLC-36, becomes an 836-AL11-NKC-36/836-H11-BLC-36.

Two Style A Pressure Controlsin One Enclosure

Page 21: 1000743 SWITCH PRESS 4-150PSI 316SS St ┌─Item Text ...€¦ · 1000743 │switch press 4-150psi 316ss │st ┌─item text ──────────────────────────────────────────────────────────────────┐

15-19

Bulletin 836

Pressure ControlsDimension Drawings — Style A

Approximate Dimensions and Shipping WeightsDimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.

2.6(65.9)

1.63(41.3)

1.88(47.6)

0.94(23.8)

3.5(88.9)

1(25.4)

0.75(19.2)

0.97(24.6)

7/16 - 20 Thread45° FLARE

0.19(4.8)

0.14(3.6)

3/4-14Pipe Tap

0.81(20.6)

3.75(95.2)2.88(73)

0.44(11.1)

0.38(9.5)

5.5(139.7)

6.25(158.8)

0.66(16.7)

1/4-18Pipe Tap 4.34 (8.7) Dia. Mtg. Holes

0.38(9.5)

1.44(36.5)

0.38(9.5)

3.84(97.5)

3.28(80.2)

0.69(17.5)

2.22 (5.6)Dia. Mtg. Holes

2.56(65.1)

of 0.88-22.2Dia. Holes

1/2(12.7)

Conduit

4.63(117.5)

0.94(23.8)

1.34(34.1)

1.38(34.9)

0.5(12.7)

1.28(32.5)

0.81(20.6)

0.81(20.6)

7/16-20 Thread45° Flare

1.28(32.5)

CL

3.22(81.8)

1.31(33.3)

0.5(12.7)

0.69(17.5)

4.5(114.3)

7/16-20 Thread45° Flare

4-Mtg.Holes

0.2(5.2)Dia.

0.36 (9.1)Dia.

CTBR 0.63 (15.9)

5.88(149.2)

3.81(96.8)

3(76.2)

3/4-14N.P.T.

1(25.4)

7/16-20 UNF-2B

1/4-18 N.P.T.

Fitting Set Screw

1.38(34.9)

0.25 (19)Hex

1/4-18 NPT

Element

1/4-18 (6.4) NPT

Style A

Open TypeApproximate Shipping Weight 1 lb (0.45 kg)

Type 7 & 9 and 4 & 13Approximate Shipping Weight 9 lbs (4.1 kg)

Type 1Approximate Shipping Weight 2 lbs (0.91 kg)

Type 4 & 13Approximate Shipping Weight 3 lbs (1.4 kg)

Cat. No. 836-N1Approximate Shipping Weight 1/4 lb (0.1 kg)

Cat. No. 836-N40Approximate Shipping Weight 1/4 lb (0.1 kg)

Page 22: 1000743 SWITCH PRESS 4-150PSI 316SS St ┌─Item Text ...€¦ · 1000743 │switch press 4-150psi 316ss │st ┌─item text ──────────────────────────────────────────────────────────────────┐

Bulletin 836

Pressure Controls

15-20

5

Dimension Drawings — Style C

Approximate Dimensions and Shipping WeightsDimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.

➊ Cat. No.s 836-C1 and 836-C1A require a 2" swing radius from centerline of pressure connection. Mount control on 7/8" minimum spacers.

Note: N.P.T.F. — American Standard Taper Pipe Thread (Dryseal).

3.25(62.6)

4.63(117.5)

0.69(17.5)

of 0.88(22.2)Dia.

Holes

1.75(44.4)

to2.69

(68.3)1.34

(34.1)

2.56(65.1)

1.63(41.3)

1.38(34.9)

1.28(32.5)

1.28(32.5)

1/4-18 N.P.T.F.

8.63(219.1)

2.75(69.8)

3/4-14 N.P.T. Opening

1.88(47.6)

4.25(107)

2.72(69.1)

5.44(138.2)

10.25(260.4)

1/2 (12.7) Conduit Opening

CL

1.91(48.4)

1.91(48.4)

1.5(38.1)

3.66(92.9)

1.31(33.3)

1.5(38.1)

3.81(96.8)

7.56(192.1)

1.34(42.1)

6.25(158.8)

(4)-0.2 (5.2) Dia.Mtg. Holes

1.63(41.3)

1/4-18 N.P.T.F.

0.66(16.7)

of 0.75-14(19.2)

N.P.T.F.

3/4-14 N.P.T Opening

CL

5.13(130.2)3.75

(95.2)

2.56(65.1) 0.38

(9.5)1/4-18 N.P.T.F.

7.38(187.3)

8.75(222.2)

0.69(17.5)

0.5 (12.7) Dia. CTBR2 Mtg. Holes for

0.5 (12.7) Dia. Screw 4.5(114.3)

2.06(52.4)

Style C

Open Type ➊Approximate Shipping Weight 2 lbs (0.91 kg)

Type 7 & 9 and 4 & 13Approximate Shipping Weight 10 lbs (4.5 kg)

Type 1Approximate Shipping Weight 2-1/2 lbs (1.1 kg)

Type 4 & 13Approximate Shipping Weight 5 lbs (2.3 kg)

Type 4XApproximate Shipping Weight 6 lbs (2.7 kg)

5(127)

to6.25

(158.8)

1.63(41.3)

3(76.2)

2.5(63.5)

1.19(30.2)

2.06(52.4)

1/4-18 N.P.T.F.

0.94(23.8)