10-day quick shipment program airo - hubbellcdn · 10-day quick shipment program airo series...

3
Airo Luminaire / Pole Combination 10-DAY QUICK SHIPMENT PROGRAM PRONTO COMBO 10-DAY QUICK SHIPMENT PROGRAM One of our most popular area lights paired with our most popular poles! • Three Sizes Up to 18,000 Lumens • Single & Double 180 deg. Configurations 4000K & 5000K CCT (70 CRI) • Type III & IV Distributions • Optional 7-pin ANSI Twist-Lock PC Receptacle for Daylight and Wireless Control • Dark Bronze Powder Paint (textured) SSS Series Poles 10-Day Quick Shipments • Square Straight Steel Construction • 4˝ Square x 0.125˝ Wall Thickness • 16’, 20’, & 25’ Lengths • Pole Base Accomodates 8˝-10˝ bolt circles using four (4) 3/4˝ diameter anchor bolts • Dark Bronze Powder Paint (textured) • With or Without Anchor Bolts • Select Configurations Include Vibration Damper • All Product Manufactured and Ship From Christiansburg, VA Within 10 Days • Consolidated Shipment – Everything Arrives On One Truck! • All Configurations Available Less Anchor Bolts • Stocked Anchor Bolts & Templates Available for Advanced Foundation Construction 10 DAY QUICK SHIPMENT PROGRAM

Upload: vudien

Post on 03-Jul-2018

216 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 10-DAY QUICK SHIPMENT PROGRAM Airo - hubbellcdn · 10-DAY QUICK SHIPMENT PROGRAM Airo Series Luminaire AVAILABLE CONFIGURATIONS 8 Performance Data Series Number ... ASCE7-05 WIND

Airo L u m i n a i r e / P o l e C o m b i n a t i o n10-DAY QU ICK SH IPMENT PROGRAM

PRONTO COMBO10-DAY QUICK SHIPMENT PROGRAM

One of our most popular area lights paired with our most popular poles!

• Three Sizes Up to 18,000 Lumens• Single & Double 180 deg. Configurations 4000K & 5000K CCT (70 CRI)• Type III & IV Distributions• Optional 7-pin ANSI Twist-Lock PC Receptacle for Daylight and Wireless Control• Dark Bronze Powder Paint (textured)

SSS Series Poles 10-Day Quick Shipments

• Square Straight Steel Construction• 4˝ Square x 0.125˝ Wall Thickness• 16’, 20’, & 25’ Lengths• Pole Base Accomodates 8˝-10˝ bolt circles using four (4) 3/4˝ diameter anchor bolts • Dark Bronze Powder Paint (textured)• With or Without Anchor Bolts• Select Configurations Include Vibration Damper

• All Product Manufactured and Ship From Christiansburg, VA Within 10 Days• Consolidated Shipment – Everything Arrives On One Truck!• All Configurations Available Less Anchor Bolts• Stocked Anchor Bolts & Templates Available for Advanced Foundation Construction

10 DAY QUICK SHIPMENT PROGRAM

Page 2: 10-DAY QUICK SHIPMENT PROGRAM Airo - hubbellcdn · 10-DAY QUICK SHIPMENT PROGRAM Airo Series Luminaire AVAILABLE CONFIGURATIONS 8 Performance Data Series Number ... ASCE7-05 WIND

PRONTO COMBO10-DAY QUICK SHIPMENT PROGRAM

AVA I L A B L E C O N F I G U R AT I O N SAiro Series Luminaire

8 Performance Data

Series Number

HID Equivalency Lumens DeliveredNumber of LEDs

System Watts

Lumens Per Watt Type 4

CCT Drivers / CurrentMH HPS Type 3 Type 4

ASL-8L 175w - 250w 175w - 250w6139 6285 8 62 101 5000K 1@2100mA

5624 5757 8 62 93 4000K 1@2100mA

16 -20 ft.TYP ICAL MOUNTING

HE IGHT

16 Performance Data

Series Number

HID Equivalency Lumens DeliveredNumber of LEDs

System Watts

Lumens Per WattType 4

CCT Drivers / CurrentMH HPS Type 3 Type 4

ASL-16L 250w - 400w 250w - 400w12175 12463 16 123 101 5000K 1@2100mA

11153 11417 16 123 93 4000K 1@2100mA

20 -25 ft.TYP ICAL MOUNTING

HE IGHT

24 Performance Data

Series Number

HID Equivalency Lumens DeliveredNumber of LEDs

System Watts

Lumens Per WattType 4

CCT Drivers / CurrentMH HPS Type 3 Type 4

ASL-24L 400w+ 400w+17863 18287 24 181 101 5000K 1@2100mA

16364 16752 24 181 93 4000K 1@2100mA

25 ft.TYP ICAL MOUNTING

HE IGHT

HID

Equi

vale

nt =

250

W -

400

W L

amp

HID

Equi

vale

nt =

400

W+

Lam

p

50‘

0‘

25‘

50‘

25‘

0‘

75‘

50‘

25‘

50‘

25‘

75‘

75‘ 75‘

50‘

0‘

25‘

50‘

25‘

0‘

75‘

50‘

25‘

50‘

25‘

75‘

75‘ 75‘

40‘

20‘

40‘

20‘

60‘

40‘

20‘

40‘

20‘

60‘

60‘ 60‘

0‘ 0‘

40‘

20‘

40‘

20‘

60‘

40‘

20‘

40‘

20‘

60‘

60‘ 60‘

0‘ 0‘

32‘

0’

16‘

32‘

16‘

0’

48‘

32‘

16‘

32‘

16‘

48‘

48‘ 48‘

32‘

0’

16‘

32‘

16‘

0’

48‘

32‘

16‘

32‘

16‘

48‘

48‘ 48‘

ASL-8L-4K-T3vs. 175 MH (horizontal lamp)

ASL-8L-4K-T4vs. 175 MH (horizontal lamp)

ASL-16L-4K-T3vs. 250 MH (horizontal lamp)

ASL-16L-4K-T4vs. 250 MH (horizontal lamp)

ASL-24L-4K-T3

ASL-24L-4K-T4

HID

Equi

vale

nt =

150

W -

250

W L

amp

25 FT.GR ID SPACING

20 FT.GR ID SPACING

400W HID181W LED

0.5 Foot-candles

0.5 Foot-candles

250W HID123W LED

0.5 Foot-candles

0.5 Foot-candles

175W HID 62W LED

16 FT.GR ID SPACING

0.5 Foot-candles

0.5 Foot-candles

16´ Mounting Height

16´ Mounting Height

20´ Mounting Height

20´ Mounting Height

25´ Mounting Height

25´ Mounting Height

PRODUCT SERIES

A

SINGLE OR DOUBLE HEAD CONFIGURATION @180 DEG.

- Single Head2X Double Head @180 Deg.

LED CCT

N 4000KC 5000K

DISTRIBUTION

T3 Type 3T4 Type 4

7-PIN TWIST LOCK PC RECEPTACLE

- No Receptacle7PR Includes Recep-

tacle

ANCHOR BOLTS

- With Anchor Bolts/Template

LAB Less Anchor Bolts/Template

POLE

S16 16’ Square Straight Steel

S20 20’ Square Straight Steel

S25 25’ Square Straight Steel

ORDERING LOGIC*

LUMENS

6 6K Nominal (ASL 8L)

12 12K Nominal (ASL 16L

18 18K Nominal (ASL 24L)

ACCESSORIES - Order Separately

Catalog Number DescriptionTAB30M38 3/4˝ x 30˝ x 3˝ anchor bolt set (four individual bolts) 93062959 SSS-H Series pole anchor bolt templatePTL-1 Photocontrol-twist-lock cell (120V) - requires 7PR optionPTL-8 Photocontrol-twist-lock cell (120V-277V) - requires 7PR optionPSC Shorting-cap-twist-lock - requires 7PR option

*25 piece max order size for 10-day shipment.

Page 3: 10-DAY QUICK SHIPMENT PROGRAM Airo - hubbellcdn · 10-DAY QUICK SHIPMENT PROGRAM Airo Series Luminaire AVAILABLE CONFIGURATIONS 8 Performance Data Series Number ... ASCE7-05 WIND

ASCE7-05 WIND MAP

180180

170

170

160

160150

150

140

140140150

140150

130120 115

115120

130

Standard ASCE7-05 Wind Map

85 MPH Zone 90 MPH Zone 100 MPH Zone 105 MPH Zone (HI) 110 MPH Zone 120 MPH Zone 145 MPH Zone (PR)

Pole Height (4”Sq x 0.125” wall thickness) 16’ 20’ 25’ 16’ 20’ 25’ 16’ 20’ 25’ 16’ 20’ 25’ 16’ 20’ 25’ 16’ 20’ 25’ 16’ 20’ 25’

Allowable EPAs (ft/sq) 19 12.7 7.3 16.7 10.9 5.9 13 7.9 3.8 11.5 6.9 2.9 7.9 4.2 0.8 7.9 4.2 0.8 4.1 1.3 NR

ASL Series - Single NR

ASL Series - DBL @ 180 deg. NR NO ASL 24 NR

Florida Region Wind Map (2010 Building Code)

115 MPH Zone 120 MPH Zone 130 MPH Zone 140 MPH Zone 150 MPH Zone 160 MPH Zone 170 MPH Zone 180 MPH Zone

Pole Height (4”Sq x 0.125” wall thickness) 16’ 20’ 25’ 16’ 20’ 25’ 16’ 20’ 25’ 16’ 20’ 25’ 16’ 20’ 25’ 16’ 20’ 25’ 16’ 20’ 25’ 16’ 20’ 25’

Allowable EPAs (ft/sq) 20.8 13.6 7.4 18.7 11.9 6.2 15.2 9.2 4.1 12.3 7.1 2.5 10.1 5.3 1.1 8.2 3.9 NR 6.7 2.7 NR 5.4 1.7 NR

ASL Series - Single NR NR NR

ASL Series - DBL @ 180 deg. NR NR NR

Acceptable Includes Vibration Damper1 ASL-24 Exceeds Allowable Pole EPA Not Recommended

Notes: 1 Pole used in program includes a vibration damper (VM2 style) due to low luminaire EPA and 25’ mounting height. *Consult the complete list of pole notes on the pole specification sheets located on the Hubbell Lighting web site.

7.16

FLORIDA REGION WIND MAP (2010 FLORIDA BUILDING CODE)

Florida Building Code utilizes a different calculation method than ASCE, which results in different allowable EPAs. Consult your local authorities to determine which standard to use for your project

HAWAII – 105 mph PUERTO RICO – 145 mph

NOTES:• Values are based on 50 year mean recurrence interval 30’

above grade.• Hawaii has an 105 mph wind velocity.• Puerto Rico has a 125 mph wind velocity.• Caution must be exercised in determining wind velocities

in special wind areas such as:Mountainous RegionsAreas surrounding the Great Lakes or other large bodies of water or open land.Areas subject to extreme wind conditions, such as hurricanes, typhoons, cyclones, and tornadoes.Areas adjacent to airports.Any specific area with a known or suspected abnormally high intermittent wind condition caused by geography, adjacent structures, or other specific local conditions that may not be recorded in National Weather Service records.

• Allowable pole EPA for jobsite wind conditions must be equal to or greater than fixture EPA. Responsibility lies with the specifier for correct pole selection based on AASHTO wind map and job location.

• The Wind Map is intended only as a general guide. Always consult local authorities to determine maximum wind velocities, gusting and unique wind conditions for each specific application.

• CAUTION: Wind speeds and listed EPAs are for ground mounted installations. Poles mounted on structures (such as bridges and buildings) must consider vibration and coefficient of height factors beyond this general guide. Consult AASHTO standards.

• Extreme Wind Events: Hurricanes, Typhoons, Cyclones, or Tornadoes expose poles to flying debris, wind shear, and other unpredictable aerodynamic forces not indicated by the wind velocity ratings.

• Pole Strength Limited Warranty: Standard, unmodified Kim lighting Poles installed as recommended, undamaged by corrosion, or lack of maintenance, shall withstand steady wind conditions as provided on page 2 (Allowable Pole EPA). Installation of poles without luminaires, or attachment of any unauthorized accessories to poles shall void this warranty.

85

90

90100110120130

130

140

140

140

150

150

140130

12011010090

Special Wind Region(Consult Local Authorities)

90Wind Map

United States and Canada

• Florida region wind map above is based upon 3-second gust winds and the 2010 Florida Building Code

120 110100

90

90

90

100110120

130

130130

130