1 zeeman patterns in ft resolved fluorescence spectra of nih amanda ross, patrick crozet, heather...

18
Zeeman patterns in FT resolved fluorescence spectra of NiH Amanda Ross, Patrick Crozet, Heather Harker and Cyril Richard Laboratoire de Spectrométrie Ionique et Moléculaire (LASIM), Université Lyon 1 & CNRS, 69622 Villeurbanne, France. and Stephen Ashworth School of Chemistry, University of East Anglia, Norwich NR4~7TJ,UK Illustrating electronic structure variations in Doppler-limited spectra. 0,72 T 0.13 T 0 T 17408.5 17409.5 cm -1

Upload: hugo-steven-bond

Post on 13-Dec-2015

222 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 1 Zeeman patterns in FT resolved fluorescence spectra of NiH Amanda Ross, Patrick Crozet, Heather Harker and Cyril Richard Laboratoire de Spectrométrie

Zeeman patterns in FT resolved fluorescence spectra of NiH

Amanda Ross, Patrick Crozet, Heather Harker and Cyril Richard

Laboratoire de Spectrométrie Ionique et Moléculaire (LASIM),Université Lyon 1 & CNRS, 69622 Villeurbanne, France.

and

Stephen Ashworth

School of Chemistry, University of East Anglia, Norwich NR4~7TJ,UK

Illustrating electronic structure variations in Doppler-limited spectra.

0,72 T

0.13 T

0 T

17408.5 17409.5 cm-1

Page 2: 1 Zeeman patterns in FT resolved fluorescence spectra of NiH Amanda Ross, Patrick Crozet, Heather Harker and Cyril Richard Laboratoire de Spectrométrie

2

FT Zeeman experiment. LIF + Nd-Fe-B magnets

External magnetic field

fluorescence

Linearly polarisedlaser beam

FTS

Polariser (optional)

Cu anode

Ni cathode

Adjustable gap

Page 3: 1 Zeeman patterns in FT resolved fluorescence spectra of NiH Amanda Ross, Patrick Crozet, Heather Harker and Cyril Richard Laboratoire de Spectrométrie

3

Zero-field NiH fluorescence spectrum (FT)

Isotopic selection is possible.

Res. 0.05 cm-1, Rec. time 2 hrs.

Abundant rotational relaxation in B state.Strong, collisionally induced fluorescence

Page 4: 1 Zeeman patterns in FT resolved fluorescence spectra of NiH Amanda Ross, Patrick Crozet, Heather Harker and Cyril Richard Laboratoire de Spectrométrie

4

Emission from excited states E ~17400 cm-1 in NiH

Observe fluorescence from to spin-orbit mixed, and states.

Laser pumps a chosen J

and parity (sometimes)

level of v=1, B 25/2 58NiH

Collisional energy transfer

populates many more!

Q1: Are the Zeeman

patterns useful?

Q2 : Can we model them?

Q3: Is this process MJ

selective?

Emission to X 25/2, v=0-3

E cm-1

Page 5: 1 Zeeman patterns in FT resolved fluorescence spectra of NiH Amanda Ross, Patrick Crozet, Heather Harker and Cyril Richard Laboratoire de Spectrométrie

5

Some lines show more ‘potential’ than others

R branch, B-X1 58NiH, observed as rotational relaxation

when laser pumped Q(2½) B-X1. Resolution = 0.025 cm-1 , field = 0,72 T

Page 6: 1 Zeeman patterns in FT resolved fluorescence spectra of NiH Amanda Ross, Patrick Crozet, Heather Harker and Cyril Richard Laboratoire de Spectrométrie

6

The strongest line in the spectrum Q(2½) B 25/2-X1 25/2

happens to have unresolved MJ structure (and doubling)

MJ = 0, ±1

MJ = 0 MJ = +1

Dispersed fluorescence shows all allowed transitions

MJ = -1

Convenient for magnetic field calibration!

LASER

Page 7: 1 Zeeman patterns in FT resolved fluorescence spectra of NiH Amanda Ross, Patrick Crozet, Heather Harker and Cyril Richard Laboratoire de Spectrométrie

7

Pumped Q(2 ½) MJ=0 B= 7200 Gauss

17408.5 17409.0 17409.5 cm -1

Calc. MJ=±1

P(3½) [1-0] line, B 25/2–X 25/2 58NiH

Calc MJ=0

FTS, ~ Doppler limited spectrum

Landé factors are known : McCarthy et al JCP 107 4179 (1997)

+1/2

-3/2

+3/2

+5/2

+7/2

-1/2

-7/2

-5/2

-3/2

-1/2

+1/2 +3/2

MJ" -1/2 +1/2

-5/2 +5/2

+3/2-3/2

17408.6 17409.0 17409.4 cm -1

17408.6 17409.0 17409.4 cm -1

MJ"

Page 8: 1 Zeeman patterns in FT resolved fluorescence spectra of NiH Amanda Ross, Patrick Crozet, Heather Harker and Cyril Richard Laboratoire de Spectrométrie

8

Can we select MJ components ? P(3½) B-X1 again

Near laser, to v"=0Transition to X1 v"=2

Populate all MJ’

- 2½ ≤ M J' ≤ 2½

Popu1ate all MJ’ except MJ2½

Laser(scatter)

Populate only MJ' = 2½

MJ" = 3½

0.72 T

0.73 T

Caveat :even uglier because of the onset of doubling

Page 9: 1 Zeeman patterns in FT resolved fluorescence spectra of NiH Amanda Ross, Patrick Crozet, Heather Harker and Cyril Richard Laboratoire de Spectrométrie

9

MJ is enhanced even after collisions (J+1) within a given state

0.7 T

Page 10: 1 Zeeman patterns in FT resolved fluorescence spectra of NiH Amanda Ross, Patrick Crozet, Heather Harker and Cyril Richard Laboratoire de Spectrométrie

10

Simplify by recording fluorescence through a polarizer. Example : collisionally induced fluorescence, R head, F 27/2 -X1 25/2

R(J") 2.5 3.5

6.5 5.5 4.5

MJ = 0

MJ = ± 1

MJ = 0, ± 1

Page 11: 1 Zeeman patterns in FT resolved fluorescence spectra of NiH Amanda Ross, Patrick Crozet, Heather Harker and Cyril Richard Laboratoire de Spectrométrie

11

Another example where the polariser really helps

P(3½) B 25/2 – X1 25/2 P(3½) I – X2

23/2

all

MJ 0, ± 1 can be distinguished for some ‘new’ transitions

Page 12: 1 Zeeman patterns in FT resolved fluorescence spectra of NiH Amanda Ross, Patrick Crozet, Heather Harker and Cyril Richard Laboratoire de Spectrométrie

12

Zeeman structure does not always collapse at high J

Example : P branch, I – W 23/2

Pf (6½) Pe (6½)

0.72 Tesla

Page 13: 1 Zeeman patterns in FT resolved fluorescence spectra of NiH Amanda Ross, Patrick Crozet, Heather Harker and Cyril Richard Laboratoire de Spectrométrie

13

Any new results ?

58NiH : extension to v" =1, 2 in X125/2 , X2

23/2 and to v=1 in

the W1 23/2 state.

60NiH : a lot of measurements …

Fit ~ 1100 transitions (from 2 spectra) to simple expression

to find T, geff(J, parity)

Effective Landé factors geff can be predicted from the Field group

Supermultiplet model (zero field fit) & Zeeman Matrix.

Page 14: 1 Zeeman patterns in FT resolved fluorescence spectra of NiH Amanda Ross, Patrick Crozet, Heather Harker and Cyril Richard Laboratoire de Spectrométrie

14

Spin-Orbit Coupling + L and S uncoupling off diagonal matrix elements

v 0 Idem x FC factors

Current fit status : unstable !

2+ 21/2 23/2

23/2 25/2

2+ Spin-Orbit A.L.S

Rotation 2.L.S -2.J.S - 2 J.L

Rotation - 2 J.L

21/2 Rotation -2.J.S Rotation - 2 J.L

23/2 Rotation 2.L.S

Rotation - 2 J.L

23/2 Spin-Orbit A L.S

Rotation -2.J.S

25/2

Supermultiplet model given by Gray et al, J. Chem. Phys 95 7164 (1991)

Page 15: 1 Zeeman patterns in FT resolved fluorescence spectra of NiH Amanda Ross, Patrick Crozet, Heather Harker and Cyril Richard Laboratoire de Spectrométrie

15

Zeeman matrix, at given J.

1/2 3/23/2 5/2

gs

(6/2) . J(J+1)-3/4

1/2 gs

gs J(J+1)-3/4

2 J(J+1)-15/4

J(J+1)-15/4

3/2 gs

gs J(J+1)-15/4

2

3/2 gs

5/2 gs

Page 16: 1 Zeeman patterns in FT resolved fluorescence spectra of NiH Amanda Ross, Patrick Crozet, Heather Harker and Cyril Richard Laboratoire de Spectrométrie

16

Satisfactory outcome … Example, W1, 23/2

v=0 2

v=0 69 67

v=0 6 6

v=1 1

v=1 0 2 79

v=1 20 20 8

v=2 2

v=2 8

% Composition Parity e f e

f

Pe( 5½)

I – W1 (0-0)

Pf (5½)

Page 17: 1 Zeeman patterns in FT resolved fluorescence spectra of NiH Amanda Ross, Patrick Crozet, Heather Harker and Cyril Richard Laboratoire de Spectrométrie

17

Comments, Conclusions and Acknowledgements

Isotopic selectivity is a real advantage.

Collecting all data in identical conditions is great!

S/N ratio is a problem, particularly with single MJ selection

Polariser alignment is critical.

Analysis is the rate determining step.

We are grateful to the CNRS and to ANR for the financial support received for this project.

Many thanks for comments, encouragement and suggestions from R. Field, D. Tokaryk, C. Linton, T. Steimle, A. Ariste-Lopez …

Page 18: 1 Zeeman patterns in FT resolved fluorescence spectra of NiH Amanda Ross, Patrick Crozet, Heather Harker and Cyril Richard Laboratoire de Spectrométrie

18

More examples in collisionally induced systems Q branch of F 27/2 -X1 25/2 and R branch of A 25/2 -X1 25/2

Analysis of Zeeman structure gives g ~ 3 for F 27/2 , as expected; but g ~ 2 for A 25/2 . Already established by RWF and coworkers …

0.71 Tesla

Zero field

Resolution 0.02 cm-1.330 scans

12000 – 17500 cm-1