1 vertex distance 2 pupilar distance - fea industries, inc.hold the personalization key vertically...

2
Pupilar Distance 2 Personalization Key can easily measure the pupilar distances as you would with any PD Ruler Vertex Distance 1 Personalization Key can easily measure the vertex distances, which is the measurement between the cornea and the back surface of the lens. Hold the Personalization Key horizontally, aligning the Vertex Distance Scale with the wearer’s corne. Measure between the cornea and the back side of the lens for the vertex distance. Wrapping Scale Frame Reference Line Pantoscopic Indicator R Ruler For Box M Measurements Frame Supporting Curve Pantoscopic Scale Lens Edge Reference Line Wrapping Indicator Ve ertex Distance Scale Pupilar Pupilar Distance Scale Powered By

Upload: others

Post on 20-May-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 1 Vertex Distance 2 Pupilar Distance - FEA Industries, Inc.Hold the Personalization Key vertically with the frame reference line facing the patient’s eyewear, both upper and lower

Pupilar Distance2

Personalization Key can easily measure the pupilar distances as you would with any PD Ruler

Vertex Distance1

Personalization Key can easily measure the vertex

distances, which is the measurement between the

cornea and the back surface of the lens.

Hold the Personalization Key horizontally, aligning the Vertex Distance Scale with the wearer’s corne. Measure between the cornea and the back side of the lens for the vertex distance.

WrappingScale

Frame Reference Line

PantoscopicIndicator

RRuler For BoxMMeasurements

FrameSupporting Curve

PantoscopicScaleLens Edge

Reference Line

Wrapping Indicator

Veertex Distance Scale

PupilarPupilarDistance Scale

Powered By

Page 2: 1 Vertex Distance 2 Pupilar Distance - FEA Industries, Inc.Hold the Personalization Key vertically with the frame reference line facing the patient’s eyewear, both upper and lower

Pantoscopic Tilt3

The wearer should be standing

in a normal posture wearing the

eyewear to be measured.

Hold the PersonalizationKey vertically with the frame reference line

facing the patient’s eyewear, both upper and lower borders of the frame have to touch the frame supporting curve. Center the frame in

respect to the frame reference line.

Pantoscopic indicator shows the Pantoscopic angle value on the

pantoscopic scale.

a

b

Wrapping (Faceform) AnglePlace Parameter Key on the desk and open it

as illustrated below

4

The wrapping angle

will be given by the

Wrapping indicator.

Open the ruler as illustrated. Place the frame so that the centre of the bridge lays directly over the Personalization Key center screw. Adjust the Lens Edge Reference Lines so that both reach the frame corner to corner.

Powered By