1 the yl9100s hplc all your needs for semi-preparative applications
TRANSCRIPT
1
The YL9100The YL9100SS HPLC HPLC
All your needs for semi-preparative applications
2
YL9100S HPLC OverviewYL9100S HPLC Overview
Superior Performance
Greater Reliability
Excellent Usability
Serviceability and Easy Maintenance
3
YL9100S HPLC – Features 1 YL9100S HPLC – Features 1
Higher performance solvent delivery pump - New designed carrier assembly and CAM - Improvement of precision
Better UV/Vis detector with new optic design - For better light intensity and higher sensitivity
New Detector – Photo Diode Array with excellent sensitivity Semi-prep flow cell is available
Superior PerformanceSuperior Performance
4
YL9100S HPLC – Features 2 YL9100S HPLC – Features 2
Greater ReliabilityGreater Reliability
Improvement of System components - New designed main parts of Pump, Detectors and Column compartment with very robust materials
Innovative manufacturing process - Three step quality control and assurance system
5
YL9100S HPLC – Features 3YL9100S HPLC – Features 3
Excellent UsabilityExcellent UsabilityExcellent UsabilityExcellent Usability
Intuitive, intelligent and powerful software - Easy control window for instruments of YL9100S HPLC - Harmonization Microsoft’s standards for accessing flies, reviewing data and reports, and other tasks - System Suitability Test with USP, EP and JP - Compliance with 21 CFR Part 11 - Diagnostics and Error detection Automation Perfectly of Analysis work - Startup, analysis operation, shut down, … , and to report generation
6
YL9100S HPLC – Features 4YL9100S HPLC – Features 4
Serviceability and Easy MaintenanceServiceability and Easy MaintenanceServiceability and Easy MaintenanceServiceability and Easy Maintenance
Better long-life components - New designed the carrier, CAM, needle bearing, seals and belt (with polyurethane) for long-life time - New designed the Deuterium and Tungsten lamp guaranteed 2,000 hours - Semi-permanent peltier in the Column Compartment
Easy Maintenance - Easy replacement and pre-alignment of lamps - Easy replacement of sample cell assembly - Diagnostics procedure by software
7
YL9100S HPLC – ModulesYL9100S HPLC – Modules
List of Modules
Degassing Module Pump Column Compartment UV/Vis Detector PDA Detector Refractive Index Detector Prep Autosampler Fraction Collector Chromatography Data System
8
YL9100S HPLC – Modules -HDVMYL9100S HPLC – Modules -HDVM
YL9101S Vacuum Degasser- - No fluctuationNo fluctuation, shorten warming upshorten warming up
Number of channel : 2 CHs (option: 4 CHs)
Maximum degassing range: 50ml/min
High capacity of chamber: 62ml per channel
Safety & maintenance : Vacuum Error detection
Wide range of Line Voltage : 100-240VAC, ±10%, Wide range
Line frequency : 50/60Hz, ±5%
Power consumption : 50W
YL9101S Vacuum Degasser will be available by JuneYL9101S Vacuum Degasser will be available by June
9
YL9100S HPLC – Modules -HDVMYL9100S HPLC – Modules -HDVM
Helium Degassing Valve Module
Number of channel : 4 CHs
Degassing type: Helium gas
(This module is required a He gas cylinder)
Wide range of Line Voltage : 100-240VAC
Line frequency : 50/60Hz
10
YL9100S HPLC – Modules -VDYL9100S HPLC – Modules -VD
Vacuum Degasser – Stand-alone type
Number of channel : 2 CHs
Maximum degassing range: 50ml/min
Wide range of Line Voltage : 100-240VAC
Line frequency : 50/60Hz
Power consumption : 46W
11
YL9100S HPLC – Modules – YL9100S HPLC – Modules – PumpPump
YL9110S Quaternary Pump
YL9111S Binary Pump
YL9112S Isocratic Pump
New design of mechanical parts of pumps
Compressibility Compensation technology
Semi-automatic Prime/Purge
Built-in Leak sensor
Wide flow range by each check valve with two balls
Ultra robust carrier, bearing, belt, etc
For isolation and purification of preparative HPLC
Flow rate: max. 50ml/min
12
YL9100S HPLC – Modules – YL9100S HPLC – Modules – BPBP
YL9111S Binary Pump (Recommended for Semi-prep)
A New Pump for higher throughput and reproducibility
The best pump for High Pressure Gradient System
Built-in Large capacity static mixer
X2 Parallel dual-plunger
Attractive price compared to QP
Ideal pump for semi-prep application
13
YL9100S HPLC – Modules – YL9100S HPLC – Modules – QP/IPQP/IP
YL9110S Quaternary Pump
Attached 4-way mixing valve to QP
YL9112S Isocratic Pump
Improved Isocratic Pump with parallel dual-plunger
Easy upgraded from IP to QP
14
YL9100S HPLC – Modules -CCYL9100S HPLC – Modules -CC
YL9130S Column Compartment- - Powerful temperature controlPowerful temperature control
The best temperature precision: ±0.05°C
Powerful Cooling is the standard: down to 4 °C
Preheating available
Semi-automatic injector/Switching valve: up to 1(option)
Column capacity: 300mm – 2ea
Leak sensor
40 steps programming
Column OD: up to 28mm
15
YL9100S HPLC – Modules -UVDYL9100S HPLC – Modules -UVD
YL9120S UV/Vis Detector- - Excellent sensitivityExcellent sensitivity
New designed Optic structure: Seya-Namioka
New Blazed Holographic Concave Grating
Excellent Data acquisition rate: up to 50 Hz
Long-life D2 lamp, 2000 hours guarantee
Advanced band width: 5.5 nm
Excellent Sensitivity: <±0.5 x 10-5 AU at 254nm
Integrated cell and slit assembly
Greater cooling of the lamp’s thermal environment
Optimal cell volume and path length for semi-preparative purpose
Leak sensor
16
YL9100S HPLC – Modules -UVDYL9100S HPLC – Modules -UVD
YL9120S UV/Vis Detector
What is the Seya-Namioka monochromator
- To attach New Blazed Holographic Concave Grating
- Extremely low stray light
- Highest light intensity
- Reduced astigmatism
- Very compact design and size
- More serviceability
- High performance beam splitter
- New designed an integrated cell+slit assembly
- Excellent band width, 5.5nm
17
YL9100S HPLC – Modules -PDAYL9100S HPLC – Modules -PDA
YL9160S PDA Detector
Optimum wavelength resolution: 1,024 diodes
Wide range from 190 to 950 nm
Highest Sensitivity
<±1.0 x 10-5 AU at 254nm, 2 sec rise time
<±2.0 x 10-5 AU at 254nm, 1 sec rise time
Fast data acquisition: 50 Hz
Greatest drift level
<2.0 x 10-4 AU/h at 254nm, Baseline correction
<1.0 x 10-3 AU/h at 254nm
- Highest Sensitivity- Highest Sensitivity
18
YL9100S HPLC – Modules -RIDYL9100S HPLC – Modules -RID
YL9170S RID
- For universal detection- For universal detection
RI Range : 1.00 ~ 1.75 RIU
Noise : < ±1.0 x 10-7 RIU
Linear dynamic range : 0-20000 μRIUFlow rate range : 1 ~ 50.0 ml/min
Cell pressure : 6 kg/cm2(84 psi)
19
YL9100S HPLC – Modules -ASYL9100S HPLC – Modules -AS
YL9150 Autosampler – Prep Autosampler
- Fully automated work- Fully automated work
Sample capacity: 24 vials(10ml for prep)
Sample loop: 10ml
Injection: partial loop
RSD ≤ 1.0% for partial loopfill.
Carry-over < 0.1%
Option: Built-in Peltier cooling (4oC ~ ambient –3oC)
20
YL9100S HPLC – Modules -FCYL9100S HPLC – Modules -FC
Fraction Collector – FC204/203B
A stand-alone operation using time, drop or peak based collection
Collect fractions by time, drop or peak with ease; manual collection is also available
Simply set the time or number of drops, press START and walk away
Drop counting: Up to 9,999 drops per fraction Maximum rate: 20 drops/sec
HELP, YES, NO, 0-9 numeric hard keys/four soft keys
2-line, 24-character display on backlit LCD
21
YL9100S HPLC – Modules -CDSYL9100S HPLC – Modules -CDS
YL-Clarity CDS
- Intelligent and Powerful Chromatography Data Station- Intelligent and Powerful Chromatography Data Station
1
MeasuringFour Instruments up to 12 detectors.
2
Post-runAutomatically displays, prints, exports and starts other programs
22
YL9100S HPLC – Modules -CDSYL9100S HPLC – Modules -CDS
3Column performanceMethod validationBy USP, EP and JP
4User accountsSets up access rights and passwords
5Audit trailRecords selected events and operations into a special file.
6Electronic signatureEach chromatogram can be signed electronically.
7Networked SolutionClarity files can be accessed from networked computers using Clarity Offline software.
8Great CompatibilityWindow XP/2000.Window Me/98, and Window Vista (32bit) is available
23
YL9100S HPLC – Modules -CDSYL9100S HPLC – Modules -CDS
YL-Clarity CDS
Perfectly compliance with 21CFR Part 11
GPC option available
System Suitability Test option available(Method validation)
PDA module option available: 3-D data analysis
Software Validation option available: Software OQS/W validation kit