1 prototype calibration system for forward hadron calorimeter l. almeida, m. baarmand, l. caraway,...

25
1 Prototype Calibration System for Forward Hadron Calorimeter L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH 1->9 light splitter w/ pulsed LEDs, input for UV laser pulses, and PIN diode light monitoring 1->4 light splitter Electronic pulser for ~100 ns LED pulses w/ single-shot and external trigger capability 10 m jacketed light fiber

Upload: leona-flowers

Post on 20-Jan-2016

214 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 1 Prototype Calibration System for Forward Hadron Calorimeter L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH

1

Prototype Calibration System for Forward Hadron Calorimeter

L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. VodopianovFLORIDA TECH

1->9 light splitter w/ pulsed LEDs, input for UV laser pulses, and PIN diode light monitoring

1->4 light splitter

Electronic pulser for~100 ns LED pulsesw/ single-shot andexternal triggercapability10 m jacketed light fiber

Page 2: 1 Prototype Calibration System for Forward Hadron Calorimeter L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH

2

N2 Laser

300 QQ 75m

9 PMT Boxes

9 PMT Boxes

9 PMT Boxes

9 PMT Boxes

Calib

Box

1 4

Counting Room

HF Calibration Optical Fiber Path Test Beam 2002

200 J 337 nm

Bottom Rack 9

600 QP 18m

300 QQ

9m

Page 3: 1 Prototype Calibration System for Forward Hadron Calorimeter L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH

3

LED 2

MIXER 50mm 15mm 15mm

PolystyrenePIN3

ADC

9600 QP

300 QQ

Blue Scintilator 8mm 4mm 8mm

Calibration Box 1 x 9 splitter

To PMT Box

PIN Diode 4mm 4mm

Pulser

PIN1PIN2

LED 1

Page 4: 1 Prototype Calibration System for Forward Hadron Calorimeter L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH

4

Page 5: 1 Prototype Calibration System for Forward Hadron Calorimeter L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH

5

Calibration Tube

Empty PMT TUBE (CLI)

Light GuideNon-reflective coating

Light Guide

600 QP

PMT BOX

5

120

SHIELDING

600 QP

40cm

Light GuidePMT

Page 6: 1 Prototype Calibration System for Forward Hadron Calorimeter L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH

6

SMA Connector

Fiber 600 QP

Jacket

SMA Connectors

Holographic Diffuser

Plate 2Plate 3

SMA-SMA connector

Fiber Ferrule

Calibration Light Injector (CLI)

Calibration Tube

9cm

Aspheric Lens 11mm Focal Length

Collimation Assembly

Page 7: 1 Prototype Calibration System for Forward Hadron Calorimeter L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH

7

One-PE Response:

Plot#1 111 or 117 ADC counts

Plot#2 106 ADC counts

Plot#3 104 ADC counts

=> stable laser pulse

1 2

3

Page 8: 1 Prototype Calibration System for Forward Hadron Calorimeter L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH

8

Page 9: 1 Prototype Calibration System for Forward Hadron Calorimeter L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH

9

PMT 154 (315 E22) behavior

PMT relative gains for ROBOX 3 measured in Iowa:

PMT N 148 149 150 151 152 153 154 155 156 157 158 159 160 161…Gain % 48 74 74 76 76 76 77 78 96 97 98 100 102 104…

High output, narrow peak Usual pedestal …

Page 10: 1 Prototype Calibration System for Forward Hadron Calorimeter L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH

10

PM

T (

PE)

/ (L

aser

/ Laser1

00%

)

Page 11: 1 Prototype Calibration System for Forward Hadron Calorimeter L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH

11

1 LED at threshold V

2 LED at 10 V

LED Data

Page 12: 1 Prototype Calibration System for Forward Hadron Calorimeter L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH

12

Page 13: 1 Prototype Calibration System for Forward Hadron Calorimeter L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH

13

Comparison of PMT response to laser and LED at similar light intensity

Page 14: 1 Prototype Calibration System for Forward Hadron Calorimeter L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH

14

2 LED at 10 V (close intensity) Laser 48%

Page 15: 1 Prototype Calibration System for Forward Hadron Calorimeter L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH

15

ADCC = (ADC-Pedestal) / Gain

Page 16: 1 Prototype Calibration System for Forward Hadron Calorimeter L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH

16ADCC

Page 17: 1 Prototype Calibration System for Forward Hadron Calorimeter L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH

17

300QQ 1000 QQ (Silica) 300 QQ

SMA Connectors

1 x 4 splitter

75 mm

Fiber to Fiber ratio = (1/0.3)2 11

Average in/out measurement 22

Page 18: 1 Prototype Calibration System for Forward Hadron Calorimeter L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH

18

Splitter studyPMT 154 “best”

1 2

3 4

1 4splitter attenuation:

no redfiber

light

1 50 43 252 49 42 223 42 36 224 43 37 18

Page 19: 1 Prototype Calibration System for Forward Hadron Calorimeter L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH

19

Page 20: 1 Prototype Calibration System for Forward Hadron Calorimeter L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH

20

Page 21: 1 Prototype Calibration System for Forward Hadron Calorimeter L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH

21

Page 22: 1 Prototype Calibration System for Forward Hadron Calorimeter L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH

22

100% laser intensity corresponds to

360 GeV electron

Page 23: 1 Prototype Calibration System for Forward Hadron Calorimeter L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH

23

100% laser int.corresponds to

933 GeV forE-PMT

1467 GeV forH-PMT

Page 24: 1 Prototype Calibration System for Forward Hadron Calorimeter L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH

24

Questions

• Are fibers in calibration and PMT bundles polished?

• How many calibration fibers are used for PMT 154 (315)? What is different in calibration lightpipe for this PMT?

• Which PMTs have bad light guides?

Page 25: 1 Prototype Calibration System for Forward Hadron Calorimeter L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH

25

Concerns• Insufficient laser intensity (attenuation factor 12 in 150m

fiber)

place UV laser closer to detector or use blue laser

• Build (or buy) low attenuation splitter