1 polarisation mode dispersion measurement piotr turowicz poznan supercomputing and networking...
TRANSCRIPT
![Page 1: 1 Polarisation Mode Dispersion Measurement Piotr Turowicz Poznan Supercomputing and Networking Center piotrek@man.poznan.pl Kiev 9-10 October 2006](https://reader034.vdocuments.mx/reader034/viewer/2022051620/56649f1c5503460f94c32866/html5/thumbnails/1.jpg)
1
Polarisation Mode DispersionPolarisation Mode DispersionMMeasurementeasurement
Piotr TurowiczPiotr TurowiczPoznan Supercomputing and Networking CenterPoznan Supercomputing and Networking Center
piotrekpiotrek@@man.poznan.plman.poznan.pl
KievKiev9-10 October 20069-10 October 2006
![Page 2: 1 Polarisation Mode Dispersion Measurement Piotr Turowicz Poznan Supercomputing and Networking Center piotrek@man.poznan.pl Kiev 9-10 October 2006](https://reader034.vdocuments.mx/reader034/viewer/2022051620/56649f1c5503460f94c32866/html5/thumbnails/2.jpg)
2
Equipment requirements.
FTB-400 mainframe equipped with GP-407.
FTB-5500B PMD analyzer
FLS-5800-xx series CD/PMD source
Toolbox office software 6.21 or higher installed on FTB-400
![Page 3: 1 Polarisation Mode Dispersion Measurement Piotr Turowicz Poznan Supercomputing and Networking Center piotrek@man.poznan.pl Kiev 9-10 October 2006](https://reader034.vdocuments.mx/reader034/viewer/2022051620/56649f1c5503460f94c32866/html5/thumbnails/3.jpg)
3
Step 1.
The FLS-5800 series source should be powered-up and allowed to complete its self test routine (less than 30 seconds). The user then has to select wavelength range and then activate the source.
C band (nominally 1510 to 1560nm) and C+L band (nominally 1510 to 1610nm).
Step 2.
Inspect and clean the connectors on the appropriate patch-cord andconnect to the source.
Step 3.
Power-on the FTB-400 and activate the FTB-5800
Step 4.
Connect the patch-cord to the input on the FTB-5800 analyser module.
![Page 4: 1 Polarisation Mode Dispersion Measurement Piotr Turowicz Poznan Supercomputing and Networking Center piotrek@man.poznan.pl Kiev 9-10 October 2006](https://reader034.vdocuments.mx/reader034/viewer/2022051620/56649f1c5503460f94c32866/html5/thumbnails/4.jpg)
4
Connecting and taking a measurement
Step 1.
The FLS-5800 series source should be powered-up and allowed to complete its self test routine.The user then has to select wavelength range and then activate the source. There are two options:C band (nominally 1510 to 1560nm) andC+L band (nominally 1510 to 1610nm).
Step 2.
Power-on the FTB-400 and activate the FTB-5500B PMD analyser software.
Step 3.
Inspect and clean the connectors on the appropriate patch-cord and connect to the source.
![Page 5: 1 Polarisation Mode Dispersion Measurement Piotr Turowicz Poznan Supercomputing and Networking Center piotrek@man.poznan.pl Kiev 9-10 October 2006](https://reader034.vdocuments.mx/reader034/viewer/2022051620/56649f1c5503460f94c32866/html5/thumbnails/5.jpg)
5
Connecting and taking a measurement
Step 5.
Check the input power level on the analyzer software. This is a basic Go/No Go indication to indicate if useable power is present before starting. This will save you time in your testing as it will indicate whether:
your source is truly activated,
if you are connected to the correct fibre(a common problem!)
and can potentially tell you to use longer averaging times(if the source signal is low)
![Page 6: 1 Polarisation Mode Dispersion Measurement Piotr Turowicz Poznan Supercomputing and Networking Center piotrek@man.poznan.pl Kiev 9-10 October 2006](https://reader034.vdocuments.mx/reader034/viewer/2022051620/56649f1c5503460f94c32866/html5/thumbnails/6.jpg)
6
Connecting and taking a measurement
Step 8
In Fiber Parameters enter the length of the link in km, select fibre type and select the wavelength range to match your FLS-5800 source settings:
The usual settings are either C+L band or O, C & L. Check the display of the FLS-5800 series source to verify.
![Page 7: 1 Polarisation Mode Dispersion Measurement Piotr Turowicz Poznan Supercomputing and Networking Center piotrek@man.poznan.pl Kiev 9-10 October 2006](https://reader034.vdocuments.mx/reader034/viewer/2022051620/56649f1c5503460f94c32866/html5/thumbnails/7.jpg)
7
Connecting and taking a measurement
Step 10
To begin a measurement, press the GREEN start button. The software automatically switches to the Results Graph screen. Note - This screen shot shows the typical data AFTER acquisition has finished and the data analysed.
![Page 8: 1 Polarisation Mode Dispersion Measurement Piotr Turowicz Poznan Supercomputing and Networking Center piotrek@man.poznan.pl Kiev 9-10 October 2006](https://reader034.vdocuments.mx/reader034/viewer/2022051620/56649f1c5503460f94c32866/html5/thumbnails/8.jpg)
8
Connecting and taking a measurement
Step 11
The output of the measurement gives the resultant interferogram, the PMD Delay in [ps] and the PMD Coefficient in [ps/Sqrt_km].
Additional information included in the output includes 2nd Order PMD, Length of sample and Wavelength range over which measurement has been performed.
![Page 9: 1 Polarisation Mode Dispersion Measurement Piotr Turowicz Poznan Supercomputing and Networking Center piotrek@man.poznan.pl Kiev 9-10 October 2006](https://reader034.vdocuments.mx/reader034/viewer/2022051620/56649f1c5503460f94c32866/html5/thumbnails/9.jpg)
9
References