30"76.2cm
24"60.96cm
X2118"
299.72cm
75"190.5cm
AA
64 12 "
163.83cm52"
131.45cm
13 12 "
33.79cm
113"287.02cm
50"126.37cm
57"144.78cm
B
B
SECTION A-A
INFLUENTSUBMERSIBLE PUMP
DISCHARGE LINE
3"7.62cm
4"10.16cm
57"144.78cm
3 12 "
8.89cm70"
177.8cm
3 12 "
8.89cm
4 12 "
11.43cm
SECTION B-B
APPROVED BY:
DRAWN BY:
REVPART NUMBER
DESCRIPTION
DO NOT SCALE DRAWING
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OF
BIO-MICROBICS, INC., ANY REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OFBIO-MICROBICS, INC. IS
PROHIBITED.
X° ±1°
SCALE: OREGON STD 0.5 LOWBOY
HRA
HRA
1:25SHEET 1 OF 1
04/15/2020
SIZE:
.X ± .50.XX ± .25
B
DATE:
APPROVED DATE:
OREGON STD MCF 0.5 LOW BOY
UNLESS OTHERWISE SPECIFIEDDIMENSIONS ARE IN INCHES ANDTOLERANCES ARE AS FOLLOWS
04/15/2020 A
Unit preceded by Oregon-approved septic tank
(/) [ ]
(/) -
[ ] ]
[
(/) [ ]
[ ]
[ ]
1·
[ ] [ ]
[ ]-- -
I [ ] [ ]
[ ]
]
[ ] ]
Pump Control Panel
Blower Housing
Ii--.. _ ___.:. 78" ----1
Vent
56_1" 2
,-------..--
Not es: State of Oregon • The inlet will not be interfered with. Deparbnentof • The outlet tee will be removed to Environmental
allow the FAST® treatment system Quality outlet to be installed properly.
• See WilJamette Graystone Tank drawing "l 000 Gallon Clamshell Septic Tank" for detailed tank dimensions.
• All exterior pipe size as per Oregon requirements.
• The volume of the septic and dosing tank will be as required in OAR 340-071.
• All connections into and out of pumping system shall be sealed and water tight.
• The pumping system must be properly vented.
• All electrical connections shall meet local codes.
• Reference "Short-FAST-ModuleProcedure" and MicroFAST drawings for additional information.
DO NOT SCALE
UNLESS NOTED DIMENSIONS ARE IN INCHES [CENTIMETERS]
TOLERANCES ± 0.02 IN/IN [± 0.05 CM/CM] Willamette MCF 0~5
WEIGHT lb SIZE DRAWING NUMBER
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIOaMICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THE INTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
BIO-MICROBICS © 2013 NAME DATE A D . s t· SHEET
i-=-D=RA""""W'-'-'N_c_TC-+-'-8/l-'l/_20_09-l-_,__ ___ o_s_1n_g_e_p_l c __ __, 1 OF 3 CHECKED PF 7/23/2013 REVISED 7/23/2013 REV. INl-02-R
-----------------------------~----~--~---------------- - -----
State of Oregon Department of Environmental Quality
Blower Housing
------- 71 "------i
Notes: • The inlet will not be interfered with. • The outlet tee will be removed to allow the FAST® treatment system
outlet to be installed properly. • See Willamette Graystone Tank drawing 111000 Gallon Clamshell Septic
Tank11 for detailed tank dimensions. • All exterior pipe size as per Oregon requirements. • The volume of the septic and dosing tank will be as required in OAR
340-071. • All connections into and out of pumping system shall be sealed and
water tight. • The pumping system must be properly vented. • All electrical connections shall meet local codes. • Reference 11Short-FAST-Module-Procedure11 and MicroFAST drawings for
additional information.
Vent
481." 4
Pump Control Panel
DO NOT SCALE
UNLESS NOTED DIMENSIONS ARE IN INCHES [CENTIMETERS]
TOLERANCES ±0.02 IN/IN [± 0.05 CM/CM]
Discharge Pipe
Pump
Willamette MCF 0.5 WEIGHT lb SIZE DRAWING NUMBER
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THE INTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
,___N_A_ME_,__D_AT_E __, A Distribution Tank SHEET B10-MICROBICS © 2013 i-=D=RA-'-'-'W'-'-'N_c_rc-+-'-a/--'ll/_20_09--1-_,__-----~------l 2 OF 3
CHECKED PF 7/23/2013 REVISED 7/23/2013 REV. INl-02-R
Pump Control Panel
64_1" 2 ~---- 71" -----.-i
--I--- 78" ----1
Vent
63"
Notes: State of Oregon Department of Environmental Qu~lity
• The inlet will not be interfered with. • The outlet tee will be removed to
•
•
•
•
•
•
•
allow the FAST® treatment system outlet to be installed properly. See Willamette Graystone Tank drawing "l 000 Gallon Clamshell Septic Tank" for detailed tank dimensions. All exterior pipe size as per Oregon requirements. · The volume of the septic and dosing tank will be as required in OAR 340-071. All connections into and out of pumping system shall be sealed and water tight. The pumping system must be properly vented. All electrical connections shall meet local codes. Reference "Short-FAST-ModuleProcedure" and MicroFAST drawings for additional information.
DO NOT SCALE
UNLESS NOTED DIMENSIONS ARE IN INCHES [CENTIMETERS]
TOLERANCES ±0.02 IN/IN [± 0.05 CM/CM] Willamette MCF 0.75
WEIGHT lb SIZE DRAWING NUMBER
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THE INTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
1------'N=AM=Ec+--:D=AT=-E --l A Dos·,ng Sept·,c SHEET 810-MICROBICS © 2013 i-=D=RA"-'-'W-'-'-N_c_rc--+-'-a/1-'11_200_9-+---'-------~-------l 1 OF 3
CHECKED PF 7/23/2013 REVISED 7/23/2013 REV. INl-02-R
State of Oregon Department of Environmental Quality
Notes: • The inlet will not be interfered with. • The outlet tee will be removed to allow the FAST® treatment system
outlet to be installed properly. · • See Willamette Graystone Tank drawing "1000 Gallon Clamshell Septic
Tank" for detailed tank dimensions. • All exterior pipe size as per Oregon requirements. • The volume of the septic and dosing tank will be as required in OAR
340-071. • All connections into and out of pumping system shall be sealed and
water tight. • The pumping system must be properly vented. • All electrical connections shall meet local codes. _ • Reference "Short-FAST-Module-Procedure" and MicroFAST drawings for
additional information.
Vent
481_" 4
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THE INTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
B10-MICROBICS © 2013
Pump Control Panel
DO NOT SCALE
UNLESS NOTED DIMENSIONS ARE IN INCHES [CENTIMETERS].
TOLERANCES ± 0.02 IN/IN [± 0.05 CM/CM]
Discharge Pipe
Pump
Willamette MCF 0.75 WEIGHT lb SIZE DRAWING NUMBER
®
NAME DATE A Distribution Tank SHEET 1--D=RA~W~N_c_rc-i--s/1_11_200_9-+--~-----,r--------1 2 OF 3 CHECKED PF 7/23/2013 REVISED 7/23/2013 REV. INl-02-R