Page 1: 1 IHR Brochure NOV 2016 compressed

Indust r ial Heat R ecovery

SAME ENERGY - MORE POWER™

THE CHOICE IS CLEAR

Page 2: 1 IHR Brochure NOV 2016 compressed

Industr ial Heat Recovery

Combined waste heat recovery to power generation systemSame energy – more powerClearPower Systems innovative ORC Waste Heat Generator Systems generates electricity using heat that is otherwise vented to the atmosphere as an unused resource.

This waste heat or money that has already been spent in applications such as generating electricity, distributed energy systems, manufacturing processes, incineration or any other heat source is being lost or just thrown away.

The waste heat generator (or waste heat recovery system) uses waste heat to generate electricity to be sold to the grid or used to reduce electrical costs.

The ClearPower Systems slogan of “Same Energy – More Power™” is representative of the savings customers’ can expect using the ClearPower system on a heat waste stream to recoup process related cost.

Based on proven Organic Rankine Cycle technology, ClearPower’s waste heat generator and recovery system is uniquely configu-red using off the shelf technology with a purpose designed expander which guarantees efficiency and low parasitic loss that our competition cannot match.

IHR-Energy proudly represents the ClearPower Systems waste heat generator in the European, Middle East and African markets.

Page 3: 1 IHR Brochure NOV 2016 compressed

Industr ial Heat Recovery

Air Cooled Condenser

ORC

Container

Electric Panel

Breaker Power out

Pump

Waste Heat In

Waste Heat Out

Exhaust Gas Heat Exchanger

The ClearPower System is packaged in a standard 6 meter / 20 foot shipping container.The air cooled condenser and the exhaust gas heat exchanger are included as part of the system.

Page 4: 1 IHR Brochure NOV 2016 compressed

Cost savings plus environmental savingsSave Money – Save the Environment by utilizing heat that would be traditionally wasted: Measurable Cost Savings – Measurable Environmental Savings

EFFICIENTIncreases the total electrical generation efficiency of a reci-procating engine based electrical generator or any heat based electrical generating equipment

RENEWABLEThe ClearPower Systems Inc. waste heat generator can be used in conjunction with other Green/Renewable energy alternatives such as solar, municipal solid waste, and biomass to produce electrical power

COST SAVINGS INCENTIVEClearPower Systems Inc. waste heat generator system saves you money by using heat energy that is just being vented to the at-mosphere and lost. This is energy that has been paid for and yet can still o ffer a return on that cost through electrical generation for internal consumption or compensated export to the grid

ENERGYHighly efficient while operating at a low speed. Our expan-der uniquely delivers an efficient transfer of thermal energy to electrical energy, at a low speed, without expensive system control electronics

ADAPTABLEThe waste heat generator returns a very attractive return on investment. The unique design of the systems controls and balance of plant equate to lower installed cost

CONFIGURABLEThe ClearPower System will be pre-packaged to apply to specific waste heat generator applications with minimal added engineering required.

Industr ial Heat Recovery

IHR Energy is a member of:

Page 5: 1 IHR Brochure NOV 2016 compressed
Page 6: 1 IHR Brochure NOV 2016 compressed

Industr ial Heat Recovery

System Specifications CPS 70 CPS 200 CPS 500Thermal Power Input kW/MMBtu/Hr. 732 / 2.5 1,280 / 4.36 3,220 / 10.9

Electrical Power Output 77 kW 200 kW 561 kW

Working Fluid R245fa Environmentally friendly, nonflammable hydrocarbon mixture

Input Water Temperature F/C 270 / 132 320 / 160 320 / 160

Output Water Temperature F/C 240 / 116 284 / 140 293 / 145

Water Flow Rate GPM/kg/s 120 / 7.5 408 / 14.8 856 / 54

Generator Synchronous Permanent Magnet

Rotational Speed RPM 1,500 / 1,800 8,000

Output Voltage VAC 400 / 480

Output Frequency Hz 50 / 60

Skid Size: Feet (ft.)Skid Size: Centimetres (cm)

20 x 8 x 8610 x 244 x 244

16.25 x 7 x 9.2495 x 215 x 280

23 x 9.5 x 9.5701 x 290 x 290

ORC on UK ETL list for ECA incentive ? Yes (pending) Yes (pending) n/a (>200kWe)

Specifications for the clearpower systems product line

Page 7: 1 IHR Brochure NOV 2016 compressed

Let us work together and find outhow we can boost your operating budget too!IHR-Energy delivers and connects the container-solution in close collaboration with our local, qualified installers and you. We carry out service and can also provide financing, which is paid for by part of the electricity produced from your waste heat. No downpayment, and a positive cashflow to boost your operations budget from day one.

The ClearPower Systems waste heat generator system has a life-time of 20 years, and a pay-back time on the investment of down to only a few years, depending on local tariffs, rules and regulations.

Buy now - also available fully financed with positive cashflowIndustr ial Heat Recovery

Typical clearpower biogas engine integration

• The Clearpower system integrated with a biogas engine installation

• Electrical generation efficiency gains of 6 to 15 percent based on engine size

• Adding a Clearpower waste heat generator to a biogas generator set can result in higher tariff returns based on installation location

Page 8: 1 IHR Brochure NOV 2016 compressed

Industr ial Heat Recovery

SAME ENERGY - MORE POWER™THE CHOICE IS CLEAR:

IHR-Energy ApS - Industrial Heat RecoveryKobbelgårdsvej 149DK-7000 FredericiaDenmark

Get in touch: Call +45 53 76 50 07 and ask for Martin Petersen. [email protected] represents ClearPower Systems Inc on an exclusive basis in Europe, the Middle East and Africa.