Page 1: 1 Bosch Solution 16i Intrusion Control System. 2 STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property

1

Bosch Solution 16iIntrusion Control System

Page 2: 1 Bosch Solution 16i Intrusion Control System. 2 STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property

2 STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.

Features & Benefits

Quick Specs - Solution 16i New Bosch Text / ICON User Interface 16 RF or Hard Wired Zones in total 4 Areas 4 outputs on board 48 Users

Options 1A power supply Input expansion module - 16 zones Output expansion module - 8 outputs Proximity Readers in Code pads Night arm station Voice Command Module Conettix IP Module

Page 3: 1 Bosch Solution 16i Intrusion Control System. 2 STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property

3 STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.

Features & Benefits

Bosch Text-Icon Code Pad Combines industry leading ICON interface

with text display.

Full programming from the code pad facilitates easy installation and maintenance

Customers familiar with icon code pad programming will directly relate to the panel reducing training requirements

Multi area control and status display of all areas on all code pads reduces inventory as only one code pad is required. Maintenance is available from any code pad in the building reducing labour.

Optional proximity reader versions reduces false alarms due to user error

Page 4: 1 Bosch Solution 16i Intrusion Control System. 2 STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property

4

Features & Benefits

STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.

Wired or Wireless Inputs Flexible configuration of both wired and wireless

inputs facilitates easy installation and customisation to the unique needs of each installation

Wired input features Selectable EOL values Single EOL, dual / split EOL (8 zone expansion

module) Alarm + tamper 4 state monitoring Separate tamper input PGM input for RF and key-switch Sensor watch alert

Wireless input features Any combination of wired or wireless in any area RF supervision Easy enrolment of devices – learn or key in Multi RF receiver card 3 x RX (CM195) Refer to page 3 -1

of your manual

Page 5: 1 Bosch Solution 16i Intrusion Control System. 2 STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property

5

Bosch Security Systems

STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.

Refer to page 3 -4 of your manual

Page 6: 1 Bosch Solution 16i Intrusion Control System. 2 STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property

6

Features & Benefits

STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.

Communications Flexible and multiple reporting options are

available Dual reporting routes SIA, CID, Domestic dialler reporting SMS to mobiles with full text Email reports direct from the dialer Voice message reporting with addition of voice

module IP reporting with addition of IP module

Advanced features are included to aid remote programming

Compatible with most commercial modems CLI Caller Line Identification Tone bypass Fax bypass 2400 baud upload and download IP remote programming sessions with addition of

IP module

Page 7: 1 Bosch Solution 16i Intrusion Control System. 2 STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property

7

Features & Benefits

STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.

New RS485 panel LAN Commercial strength panel LAN less

susceptible to interference. It ensures system integrity is maintained and maximises customer security

Provides secure, encrypted transmission of panel data

Anti substitution protection on modules

Page 8: 1 Bosch Solution 16i Intrusion Control System. 2 STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property

8

Bosch Security Systems

STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.

Solution Common features Common Wireless options across entire

range for ease of system upgrades with minimal inventory *

All panels are Bosch DSRF compatible All panels use the RF3212E receiver

Common hold down functions across all panels increases user familiarity across sites

Fire, panic and medical

* The above applies to Solution 880Ultima, Solution 16i, Solution 16plus and Solution 64. The Solution 844 is not wireless compatible.

Page 9: 1 Bosch Solution 16i Intrusion Control System. 2 STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property

9

Features & Benefits

STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.

Solution Common features Sensor watch Area watch Line fault detection Dial and busy tone detection Reports in CID, SIA, e-mail, SMS, domestic. Redundant reporting Dual reporting 32 digit Telco numbers Call forward CLI smart answer mode All zones with programmable EOL and pulse

count Burglary and fire report delay Part mode entry timer Dual entry timers Auto arming and auto disarming

3 fully supervised and protected high current outputs

1 change over 2amp relay Optional Proximity reader built into code

pad All users with variable pin lengths 1-8 digits Programmable zone, user, output, area text In premise wireless compatible Service reminder User test reminder Time executed functions, holiday schedules

and daylight savings Senior watch Swinger siren swinger dialler

Page 10: 1 Bosch Solution 16i Intrusion Control System. 2 STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property

10 STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.

Page 11: 1 Bosch Solution 16i Intrusion Control System. 2 STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property

11

Solution 16i Modules

STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.

Night Arm Station Allows arming and disarming in part mode 1

and part mode providing no alarm has been activated

Two button panic alarm Built in sounder provides entry warning and

alarm alerts LED indicators provide system and zone

status Unobtrusive surface mount design Ideally suited to residential installations Lower price alternative to second code pad

( CP050B)

Page 12: 1 Bosch Solution 16i Intrusion Control System. 2 STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property

12

Solution 16i Modules

STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.

Relay output expander module 4 x Form C relays 2 Amp contact rating at 24VDC May be remotely located and controlled

from panel Separate tamper input Service code pad input

( CM710B)

Refer to page 2 -8 of your manual

Page 13: 1 Bosch Solution 16i Intrusion Control System. 2 STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property

13

Solution 16i Modules

STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.

8 / 16 Zone expansion module Provides 8 physical zone input terminations

per module Allows zones to be remotely located away

from control panel to reduce cabling costs Supports both LAN or external power Separate tamper input

Refer to page 2 -7 of your manual

( CM704B)

Page 14: 1 Bosch Solution 16i Intrusion Control System. 2 STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property

14

Solution 16i Modules

STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.

Multi RF Receiver Interface 3 x independent wireless receiver inputs Support for multiple vendors RF

technologies Allows increased wireless coverage and

reliability Easy 3 wire connection to the control panel Data received and processed indicators

( CM195 )

Refer to page 2 -9 of your manual

Page 15: 1 Bosch Solution 16i Intrusion Control System. 2 STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property

15

Features & Benefits

STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.

SolutionLink Installation and maintenance can be taken a

step further with the use of our advanced SolutionLink remote programming software

Built on MS SQL technology Direct & remote link options Live remote system diagnostics Resistance, voltage, version, temperature On line code pad simulator Online database / panel synchronization Summary & detail views Real time interactive mode PDF report formats Account import/export and email Comprehensive user authority levels Windows Vista and Windows 7 Compatible

Full English text for all different sensors, areas, users, time schedules. For example Kitchen Dual Tech PIR (instead of Zone 1)