1 bnsf railway company

14
1 0 Bar is one inch on original drawing. If not one inch on this drawing, adjust scales accordingly. DATE NO. BY DESCRIPTION OF REVISIONS SERVICE REQUISTION NO.: STATE PROJ. TYPE STATION FILENAME: PROJ. DESC. CHKD. DES. DRWN. DESIGN FIRM PROJ. NO. SHEET: DRAWING NUMBER OF APPROVED DRAWING DESC. TX FACILITIES HEREFORD ERIC JOHNSON 13955.114 CONCEPTUAL DESIGN 14 11/5/2021 Date Plotted: K:\a-f\BNSF\13955091\_Hereford_TX _Replacement Depot\04_Production\01_CAD\02_Sheets\HERETX-2021-B-0-G000.dwg File Path: EAL MJM EBJ MEP 70952 FACILITIES ENGINEERING 4515 KANSAS AVE. KANSAS CITY, KS. 66106 5151 Mochel Drive, Suite 205 Downers Grove, IL 60515 Phone 630 499-4110 Fax 630 499-4119 tkda.com DESIGN FIRM PROJ. MGR. 0 11/9/21 EBJ 30% ISSUE FOR BID HERETX-2021-B-0-G000.dwg TITLE SHEET, CODES, AND NOTES G000 1 REV TITLE DWG GENERAL ARCHITECTURAL G000 0 TITLE SHEET, CODES, AND NOTES A001 0 ARCHITECTURAL SITE PLAN A100 0 FLOOR PLAN A101 0 TEMPORARY MODULAR UNIT FLOOR PLAN A200 0 EXTERIOR ELEVATIONS A201 0 INTERIOR ELEVATIONS A202 0 WALL SECTIONS AND SCHEDULES A300 0 ELECTRICAL, TELECOM, AND FURNITURE PLAN REV TITLE DWG ELECTRICAL REV TITLE DWG E000 0 ELECTRICAL SYMBOLS E001 0 ELECTRICAL ABBREVIATIONS E002 0 LABELING DETAILS E003 0 LABELING DETAILS E004 0 LABELING DETAILS E005 0 GROUNDING DETAILS LIST OF DRAWINGS BNSF RAILWAY COMPANY CONCEPTUAL DESIGN FOR DEPOT FACILITY DAIRY ROAD HEREFORD, TEXAS 79045 SERVICE REQUISITION NO.: 70952 SUMMARY OF WORK BUILDING CODES 2015INTERNATIONALBUILDINGCODE 2017NATIONALELECTRICALCODE 2015INTERNATIONALENERGYCONSERVATIONCODE 2015INTERNATIONALPLUMBINGCODE 2015INTERNATIONALMECHANICAL 2015INTERNATIONALFUELGASCODE 2015INTERNATIONALFIRECODE 2012TEXASACCESSIBILITYSTANDARDS 1. ALL CONSTRUCTION SHALL COMPLY WITH THE 2015 INTERNATIONAL BUILDING CODE, CITY OF HEREFORD, COUNTY OF DEAF SMITH, STATE OF TEXAS, AND FEDERAL REGULATIONS AND THE AMERICANS WITH DISABILITIES ACT (ADA). 2. DO NOT SCALE DRAWINGS. INDICATED DIMENSIONS SHALL GOVERN. UNLESS OTHERWISE INDICATED, DIMENSIONS ARE FROM FINISHED FACE TO FINISHED FACE. 3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND RELEVANT CONDITIONS PRIOR TO PROCEEDING WITH WORK. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AS SOON AS POSSIBLE. 4. ALL GYPSUM BOARD WITHIN 24" OF PLUMBING FIXTURES SHALL BE WATER-RESISTANT TYPE. 5. PROVIDE FIRE EXTINGUISHERS AS REQUIRED BY THE LOCAL FIRE MARSHALL. EXTINGUISHERS IN FINISHED AREAS SHALL BE INSTALLED IN CABINETS. 6. THE CONTRACTOR SHALL COORDINATE ANY INTERFACE WITH LOCAL JURISDICTIONS AND UTILITY COMPANIES FOR CONNECTIONS. ALL PERMIT APPLICATION FEES AND TAP FEES SHALL BE INCLUDED IN THE BIDDERS PROPOSAL. 7. PROVIDE IDENTIFICATION SIGNAGE FOR TOILET AND SHOWER ROOMS IN ACCORDANCE WITH IBC AND STATE ORDINANCES. 8. PROVIDE ROUGH BLOCKING FOR DOOR HARDWARE, CABINETRY, SHELVING, TOILET ACCESSORIES, ETC. TO ASSURE SOLID INSTALLATION OF FIXTURES. 9. ANYTHING SUBMITTED BY OR ON BEHALF OF BNSF IN CONNECTION WITH THE HEREFORD, TEXAS DEPOT FACILITY IS VOLUNTARY AND SHALL NOT BE DEEMED A SUBMISSION BY BNSF TO THE JURISDICTION OF ANY STATE OR LOCAL BODY OR A WAIVER OF THE PREEMPTIVE EFFORT OF ANY STATE OR FEDERAL LAW. 10. STATE AND LOCAL ZONING, ENVIRONMENTAL, NOISE, NUISANCE, LAND USE, BUILDING PERMIT, AND DEMOLITION LAWS AND REGULATIONS OF RAILROAD FACILITIES ARE PREEMPTED BY THE INTERSTATE COMMERCE COMMISSION TERMINATION ACT (49 U.S.C. 10501). THE CONTRACTOR SHALL COORDINATE ANY INTERFACE WITH LOCAL JURISDICTIONS AND UTILITIES FOR CONNECTIONS. ALL APPLICATIONS AND TAP FEES SHALL BE INCLUDED IN THE BIDDERS PROPOSAL. 11. FOUNDATION DESIGN: FOUNDATION DESIGN SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. FOUNDATIONS SHALL EXTEND BELOW LOCAL FROST DEPTH PER LOCAL ORDINANCE (LOCAL FROST DEPTH ESTIMATED AT 24" BELOW GRADE MINIMUM). GENERAL NOTES IN ACCORDANCE WITH THE LATEST CORPORATE REQUIREMENTS, ALL PERSONS NOT EMPLOYED BY BNSF RAILWAY SHALL HAVE COMPLETED AN ONLINE SAFETY ORIENTATION PROGRAM TO BE ALLOWED ON THE PROPERTY. THE ORIENTATION CAN BE FOUND ON THE INTERNET AT HTTP://BNSFCONTRACTOR.COM THE CONTRACTOR IS FULLY RESPONSIBLE FOR ALL SAFETY ISSUES WITHIN THE CONSTRUCTION AREA. E-RAILSAFE COMPLIANCE CONSTRUCTION PERSONNEL SAFETY TRAINING ACT ACOUSTICAL CEILING TILE A.F.F. ABOVE FINISH FLOOR CONC. CONCRETE CONC-S CONCRETE - SEALED FRP FIBERGLASS REINFORCED PANEL G.B. GYPSUM BOARD HM HOLLOW METAL HORIZ. HORIZONTAL ARCHITECTURAL COLORS ABBREVIATIONS APPLICABLE CODES ARCHITECTURAL THE FOLLOWING INFORMATION IS NOT TENDED TO RESTRICT THE CONTRACTOR FROM COMPETITIVE SELECTION OF PRODUCTS, BUT TO PROVIDE BASIC COLOR DIRECTIONS. THE CONTRACTOR SHALL SUBMIT ALTERNATIVE MANUFACTURER'S COLOR SAMPLES FOR APPROVAL: EXTERIOR: METAL WALL PANELS: BUTLER MANUFACTURING "COOL COUNTRY WHEAT" OR APPROVED EQUAL METAL ROOF PANELS: BUTLER MANUFACTURING "COOL SOLAR WHITE" OR APPROVED EQUAL EAVES / SOFFIT / TRIM: BUTLER MANUFACTURING "COOL HARVEST" OR APPROVED EQUAL GUTTERS/ DOWNSPOUTS: BUTLER MANUFACTURING "COOL HARVEST" OR APPROVED EQUAL DOORS/ FRAMES: PAINT TO MATCH TRIM OVERHEAD DOORS: PAINT TO MATCH TRIM INTERIOR: WALL PROTECTION SYSTEM (WPS) : KOROGARD PROTECTIVE WALL COVERING "WHITE CORN" WALL PAINT: LOWE'S VALSPAR SIGNATURE COLORS “CREAM DELIGHT” #7002-14 DOOR/ FRAME PAINT: MATCH WALL BASE COLOR CARPET TILE: INTERFACE FLOR "BLACK BROWN" #603188 VCT FLOORING: ARMSTRONG STANDARD EXCELON IMPERIAL TEXTURE 51901 TAUPE VINYL WALL BASE: BURKE MERCER FLOORING #201 "CHOCOLATE" PLASTIC LAMINATE: FORMICA OXIDIZED BEAMWOOD FOR MILLWORK, WORKSTATION COUNTERTOPS, BACKSPLASHES AND SIDE SPLASHES SOLID SURFACE: CORIAN "BISQUE" COUNTERTOPS, BACKSPLASHES AND SIDE SPLASHES WINDOW SILLS: CORIAN "BISQUE" WINDOW BLINDS: BALI "COCONUT" 630 LOCKERS: ALMOND TOILET PARTITIONS: METPAR "ALMOND" - 300 PRE-EMPTION NOTICE THISPORTIONOFTRACKISANINTEGRALPARTOFBNSF'SINTERSTATE RAIL SYSTEM. UNDER THE ICC TERMINATION ACT {ICCTA}, 49 U.S.C. § 10501(B), THE FEDERAL SURFACE TRANSPORTATION BOARD HAS EXCLUSIVE JURISDICTION OVER RAILROAD OPERATIONS AND FACILITIES. ALTHOUGH STATE AND LOCAL AGENCIES DO NOT HAVE JURISDICTIONTOCOMPELRAILROADSTOSUBMITTOSTATEORLOCAL PERMITTING REQUIREMENTS AS A CONDITION OF IMPROVING THE RAILROADS' INTERSTATE FACILITIES, BNSF AND OTHER RAILROADS CAN AND OFTEN DO VOLUNTARILY AGREE TO COMPLY WITH REASONABLE STATE AND LOCAL ENVIRONMENTAL REQUIREMENTS IN CONNECTION WITH RAILROAD CONSTRUCTION PROJECTS. THIS VOLUNTARY COOPERATION IN NO WAY CONFERS JURISDICTION ON THE STATE OR LOCAL REGULATOR NOR IS IT AN ADMISSION OR AGREEMENT BY BNSF TO CONTINUE IN THIS PROCESS SHOULD IT INTERFERE WITH OUR ABILITY TO OPERATE THE RAILROAD EFFICIENTLY. INSTEAD IT IS A BY-PRODUCT OF BNSF'S COMMITMENT TO PARTNERSHIP WITH THE COMMUNITY. BNSF IS COMMITTED TO WORKING CLOSELY WITH YOUR AGENCY TO IDENTIFY REASONABLE REQUIREMENTS WE CAN MUTUALLY AGREE TO IMPLEMENT AS PART OFTHISPROJECT. MIN. MINIMUM O.C. ON CENTER P. LAM. PLASTIC LAMINATE PLYWD PLYWOOD PT PAINT VB VINYL BASE VCT VINYL COMPOSITION TILE TYP. TYPICAL PERSONNEL MAY REGISTER WITH THE PROGRAM UNDER THE GENERAL CONTRACTOR OR MAY CHOOSE TO COMPLETE THE SCREENING UNDER THEIR COMPANY . REFER TO THE BNSF STANDARD CONTRACT FORM, ARTICLE VII, OR VISIT HTTP://E-RAILSAFE.COM IN ACCORDANCE WITH THE LATEST CORPORATE REQUIREMENTS, ALL CONSTRUCTION PERSONNEL SHALL COMPLETE THE BACKGROUND SECURITY SCREENING AND OBTAIN BADGES PRIOR TO ENTERING THE SITE. DELIVERY PERSONNEL ON SITE FOR A SHORT PERIOD OF TIME AND UNDER THE DIRECT SUPERVISION OF AN E-RAILSAFE WORKER MAY CHOSE TO WAIVER THIS REQUIREMENT. 1. CONCEPTUAL DESIGN OF PROPOSED 4,368 SQ. FT. DEPOT FACILITY.

Upload: others

Post on 03-Apr-2022

7 views

Category:

Documents


0 download

TRANSCRIPT

10

Bar i

s one

inch

on

orig

inal

dra

win

g. If

not

one

inch

on

this

draw

ing,

adj

ust s

cale

s acc

ordi

ngly

.

DATENO. BY DESCRIPTION OF REVISIONS

SERVICE REQUISTION NO.:

STATE

PROJ. TYPE

STATION

FILENAME:

PROJ. DESC.

CHKD.

DES.

DRWN.

DESIGN FIRM PROJ. NO.

SHEET:

DRAWING NUMBER

OF

APPROVED

DRAWING DESC.

TX

FACILITIES

HEREFORD

ERIC JOHNSON13955.114

CONCEPTUAL DESIGN

14

11/5

/202

1Da

te P

lott

ed:

K:\a

-f\BN

SF\1

3955

091\

_Her

efor

d_TX

_Re

plac

emen

t Dep

ot\0

4_Pr

oduc

tion\

01_C

AD\0

2_Sh

eets

\HER

ETX-

2021

-B-0

-G00

0.dw

gFi

le P

ath:

EAL

MJM

EBJ

MEP

70952

FACILITIES ENGINEERING

4515 KANSAS AVE.

KANSAS CITY, KS. 66106

5151 Mochel Drive, Suite 205

Downers Grove, IL 60515

Phone 630 499-4110

Fax 630 499-4119

tkda.com

DESIGN FIRM PROJ. MGR.

0 11/9/21 EBJ 30% ISSUE FOR BIDHERETX-2021-B-0-G000.dwg

TITLE SHEET, CODES, AND NOTES

G000

1

REV TITLEDWG

GENERAL

ARCHITECTURAL

G000 0 TITLE SHEET, CODES, AND NOTES

A001 0 ARCHITECTURAL SITE PLAN

A100 0 FLOOR PLAN

A101 0 TEMPORARY MODULAR UNIT FLOOR PLAN

A200 0 EXTERIOR ELEVATIONS

A201 0 INTERIOR ELEVATIONS

A202 0 WALL SECTIONS AND SCHEDULES

A300 0 ELECTRICAL, TELECOM, AND FURNITURE PLAN

REV TITLEDWG

ELECTRICAL

REV TITLEDWG

E000 0 ELECTRICAL SYMBOLS

E001 0 ELECTRICAL ABBREVIATIONS

E002 0 LABELING DETAILS

E003 0 LABELING DETAILS

E004 0 LABELING DETAILS

E005 0 GROUNDING DETAILS

LIST OF DRAWINGS

BNSF RAILWAY COMPANY

CONCEPTUAL DESIGN FOR DEPOT FACILITY

DAIRY ROAD

HEREFORD, TEXAS 79045

SERVICE REQUISITION NO.: 70952

SUMMARY OF WORK BUILDING CODES

2015 INTERNATIONAL BUILDING CODE

2017 NATIONAL ELECTRICAL CODE

2015 INTERNATIONAL ENERGY CONSERVATION CODE

2015 INTERNATIONAL PLUMBING CODE

2015 INTERNATIONAL MECHANICAL

2015 INTERNATIONAL FUEL GAS CODE

2015 INTERNATIONAL FIRE CODE

2012 TEXAS ACCESSIBILITY STANDARDS

1. ALL CONSTRUCTION SHALL COMPLY WITH THE 2015 INTERNATIONAL BUILDING CODE, CITY OF

HEREFORD, COUNTY OF DEAF SMITH, STATE OF TEXAS, AND FEDERAL REGULATIONS AND THE

AMERICANS WITH DISABILITIES ACT (ADA).

2. DO NOT SCALE DRAWINGS. INDICATED DIMENSIONS SHALL GOVERN. UNLESS OTHERWISE INDICATED,

DIMENSIONS ARE FROM FINISHED FACE TO FINISHED FACE.

3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND RELEVANT CONDITIONS PRIOR TO PROCEEDING

WITH WORK. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AS SOON AS

POSSIBLE.

4. ALL GYPSUM BOARD WITHIN 24" OF PLUMBING FIXTURES SHALL BE WATER-RESISTANT TYPE.

5. PROVIDE FIRE EXTINGUISHERS AS REQUIRED BY THE LOCAL FIRE MARSHALL. EXTINGUISHERS IN

FINISHED AREAS SHALL BE INSTALLED IN CABINETS.

6. THE CONTRACTOR SHALL COORDINATE ANY INTERFACE WITH LOCAL JURISDICTIONS AND UTILITY

COMPANIES FOR CONNECTIONS. ALL PERMIT APPLICATION FEES AND TAP FEES SHALL BE INCLUDED IN

THE BIDDERS PROPOSAL.

7. PROVIDE IDENTIFICATION SIGNAGE FOR TOILET AND SHOWER ROOMS IN ACCORDANCE WITH IBC AND

STATE ORDINANCES.

8. PROVIDE ROUGH BLOCKING FOR DOOR HARDWARE, CABINETRY, SHELVING, TOILET ACCESSORIES, ETC.

TO ASSURE SOLID INSTALLATION OF FIXTURES.

9. ANYTHING SUBMITTED BY OR ON BEHALF OF BNSF IN CONNECTION WITH THE HEREFORD, TEXAS

DEPOT FACILITY IS VOLUNTARY AND SHALL NOT BE DEEMED A SUBMISSION BY BNSF TO THE

JURISDICTION OF ANY STATE OR LOCAL BODY OR A WAIVER OF THE PREEMPTIVE EFFORT OF ANY

STATE OR FEDERAL LAW.

10. STATE AND LOCAL ZONING, ENVIRONMENTAL, NOISE, NUISANCE, LAND USE, BUILDING PERMIT, AND

DEMOLITION LAWS AND REGULATIONS OF RAILROAD FACILITIES ARE PREEMPTED BY THE INTERSTATE

COMMERCE COMMISSION TERMINATION ACT (49 U.S.C. 10501). THE CONTRACTOR SHALL COORDINATE

ANY INTERFACE WITH LOCAL JURISDICTIONS AND UTILITIES FOR CONNECTIONS. ALL APPLICATIONS

AND TAP FEES SHALL BE INCLUDED IN THE BIDDERS PROPOSAL.

11. FOUNDATION DESIGN: FOUNDATION DESIGN SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.

FOUNDATIONS SHALL EXTEND BELOW LOCAL FROST DEPTH PER LOCAL ORDINANCE (LOCAL FROST

DEPTH ESTIMATED AT 24" BELOW GRADE MINIMUM).

GENERAL NOTES

IN ACCORDANCE WITH THE LATEST CORPORATE REQUIREMENTS, ALL

PERSONS NOT EMPLOYED BY BNSF RAILWAY SHALL HAVE COMPLETED AN

ONLINE SAFETY ORIENTATION PROGRAM TO BE ALLOWED ON THE

PROPERTY. THE ORIENTATION CAN BE FOUND ON THE INTERNET AT

HTTP://BNSFCONTRACTOR.COM

THE CONTRACTOR IS FULLY RESPONSIBLE FOR ALL SAFETY ISSUES WITHIN

THE CONSTRUCTION AREA.

E-RAILSAFE COMPLIANCE

CONSTRUCTION PERSONNEL SAFETY TRAINING

ACT ACOUSTICAL CEILING TILEA.F.F. ABOVE FINISH FLOORCONC. CONCRETECONC-S CONCRETE - SEALEDFRP FIBERGLASS REINFORCED PANELG.B. GYPSUM BOARDHM HOLLOW METALHORIZ. HORIZONTAL

ARCHITECTURAL COLORS

ABBREVIATIONS

APPLICABLE CODES

ARCHITECTURAL

THE FOLLOWING INFORMATION IS NOT TENDED TO RESTRICT THE CONTRACTOR FROM COMPETITIVE SELECTION

OF PRODUCTS, BUT TO PROVIDE BASIC COLOR DIRECTIONS. THE CONTRACTOR SHALL SUBMIT ALTERNATIVE

MANUFACTURER'S COLOR SAMPLES FOR APPROVAL:

EXTERIOR:

METAL WALL PANELS: BUTLER MANUFACTURING "COOL COUNTRY WHEAT" OR APPROVED EQUAL

METAL ROOF PANELS: BUTLER MANUFACTURING "COOL SOLAR WHITE" OR APPROVED EQUAL

EAVES / SOFFIT / TRIM: BUTLER MANUFACTURING "COOL HARVEST" OR APPROVED EQUAL

GUTTERS/ DOWNSPOUTS: BUTLER MANUFACTURING "COOL HARVEST" OR APPROVED EQUAL

DOORS/ FRAMES: PAINT TO MATCH TRIM

OVERHEAD DOORS: PAINT TO MATCH TRIM

INTERIOR:

WALL PROTECTION SYSTEM (WPS) : KOROGARD PROTECTIVE WALL COVERING "WHITE CORN"

WALL PAINT: LOWE'S VALSPAR SIGNATURE COLORS “CREAM DELIGHT” #7002-14

DOOR/ FRAME PAINT: MATCH WALL BASE COLOR

CARPET TILE: INTERFACE FLOR "BLACK BROWN" #603188

VCT FLOORING: ARMSTRONG STANDARD EXCELON IMPERIAL TEXTURE 51901 TAUPE

VINYL WALL BASE: BURKE MERCER FLOORING #201 "CHOCOLATE"

PLASTIC LAMINATE: FORMICA OXIDIZED BEAMWOOD FOR MILLWORK, WORKSTATION

COUNTERTOPS, BACKSPLASHES AND SIDE SPLASHES

SOLID SURFACE: CORIAN "BISQUE" COUNTERTOPS, BACKSPLASHES AND SIDE SPLASHES

WINDOW SILLS: CORIAN "BISQUE"

WINDOW BLINDS: BALI "COCONUT" 630

LOCKERS: ALMOND

TOILET PARTITIONS: METPAR "ALMOND" - 300

PRE-EMPTION NOTICE

THIS PORTION OF TRACK IS AN INTEGRAL PART OF BNSF'S INTERSTATE

RAIL SYSTEM. UNDER THE ICC TERMINATION ACT {ICCTA}, 49 U.S.C. §

10501(B), THE FEDERAL SURFACE TRANSPORTATION BOARD HAS

EXCLUSIVE JURISDICTION OVER RAILROAD OPERATIONS AND

FACILITIES. ALTHOUGH STATE AND LOCAL AGENCIES DO NOT HAVE

JURISDICTION TO COMPEL RAILROADS TO SUBMIT TO STATE OR LOCAL

PERMITTING REQUIREMENTS AS A CONDITION OF IMPROVING THE

RAILROADS' INTERSTATE FACILITIES, BNSF AND OTHER RAILROADS

CAN AND OFTEN DO VOLUNTARILY AGREE TO COMPLY WITH

REASONABLE STATE AND LOCAL ENVIRONMENTAL REQUIREMENTS IN

CONNECTION WITH RAILROAD CONSTRUCTION PROJECTS. THIS

VOLUNTARY COOPERATION IN NO WAY CONFERS JURISDICTION ON

THE STATE OR LOCAL REGULATOR NOR IS IT AN ADMISSION OR

AGREEMENT BY BNSF TO CONTINUE IN THIS PROCESS SHOULD IT

INTERFERE WITH OUR ABILITY TO OPERATE THE RAILROAD

EFFICIENTLY. INSTEAD IT IS A BY-PRODUCT OF BNSF'S COMMITMENT

TO PARTNERSHIP WITH THE COMMUNITY. BNSF IS COMMITTED TO

WORKING CLOSELY WITH YOUR AGENCY TO IDENTIFY REASONABLE

REQUIREMENTS WE CAN MUTUALLY AGREE TO IMPLEMENT AS PART

OF THIS PROJECT.

MIN. MINIMUMO.C. ON CENTERP. LAM. PLASTIC LAMINATEPLYWD PLYWOODPT PAINTVB VINYL BASE

VCT VINYL COMPOSITION TILE

TYP. TYPICAL

PERSONNEL MAY REGISTER WITH THE PROGRAM UNDER THE GENERAL

CONTRACTOR OR MAY CHOOSE TO COMPLETE THE SCREENING UNDER THEIR

COMPANY .

REFER TO THE BNSF STANDARD CONTRACT FORM, ARTICLE VII, OR VISIT

HTTP://E-RAILSAFE.COM

IN ACCORDANCE WITH THE LATEST CORPORATE

REQUIREMENTS, ALL CONSTRUCTION PERSONNEL SHALL

COMPLETE THE BACKGROUND SECURITY SCREENING AND

OBTAIN BADGES PRIOR TO ENTERING THE SITE. DELIVERY

PERSONNEL ON SITE FOR A SHORT PERIOD OF TIME AND

UNDER THE DIRECT SUPERVISION OF AN E-RAILSAFE

WORKER MAY CHOSE TO WAIVER THIS REQUIREMENT.

1. CONCEPTUAL DESIGN OF PROPOSED 4,368 SQ. FT. DEPOT FACILITY.

EDGE OF GRAVEL

NEW GRAVEL

EXISTING

ACCESS ROAD

APPROX.

PROPERTY

LINE

10 LARGE VEHICLE SPACES

BUILDING DRIVE AND

DELIVERY LANE

10 SPACES

6 S

PA

CE

S

PROPOSED

DEPOT FACILITY

4,368 SQ. FT.

40'x8'

STORAGE

CONTAINERS

FOR MOW

40'x8'

STORAGE

CONTAINER

FOR SIGNAL

NEW ASPHALT

PARKING

4 S

PA

CE

S

2 A

CC

ES

SIB

LE

SP

AC

ES

PROPOSED

TEMPORARY

MODULAR

1,400 SQ FT

NEW ASPHALT APRON NEW CONCRETE WALK

SLOPE AWAY FROM

BUILDING TO EXISTING

GRADE

NEW GRAVEL

10

Bar i

s one

inch

on

orig

inal

dra

win

g. If

not

one

inch

on

this

draw

ing,

adj

ust s

cale

s acc

ordi

ngly

.

DATENO. BY DESCRIPTION OF REVISIONS

SERVICE REQUISTION NO.:

STATE

PROJ. TYPE

STATION

FILENAME:

PROJ. DESC.

CHKD.

DES.

DRWN.

DESIGN FIRM PROJ. NO.

SHEET:

DRAWING NUMBER

OF

APPROVED

DRAWING DESC.

TX

FACILITIES

HEREFORD

ERIC JOHNSON13955.114

CONCEPTUAL DESIGN

14

11/5

/202

1Da

te P

lott

ed:

K:\a

-f\BN

SF\1

3955

091\

_Her

efor

d_TX

_Re

plac

emen

t Dep

ot\0

4_Pr

oduc

tion\

01_C

AD\0

2_Sh

eets

\HER

ETX-

2021

-B-0

-A00

1.dw

gFi

le P

ath:

EAL

MJM

EBJ

MEP

70952

FACILITIES ENGINEERING

4515 KANSAS AVE.

KANSAS CITY, KS. 66106

5151 Mochel Drive, Suite 205

Downers Grove, IL 60515

Phone 630 499-4110

Fax 630 499-4119

tkda.com

DESIGN FIRM PROJ. MGR.

0 11/9/21 EBJ 30% ISSUE FOR BIDHERETX-2021-B-0-A001.dwg

ARCHITECTURAL SITE PLAN

A001

2

Scale: NOT TO SCALE

ARCHITECTURAL SITE PLAN

1

20 REGULAR PARKING SPACES (10' W x 20' L)

2 ACCESSIBLE SPACES

10 LARGE VEHICLE SPACES

PARKING SUMMARY: 32 TOTAL SPACES

PER THE CONTRACT REQUIREMENTS, THE CONTRACTOR SHALL CONTACT THE BNSF DIG

LOCATE SERVICE AND INDICATE THE PROJECT IS FOR THE USE OF THE BNSF RAILWAY SO

NO COST WILL BE INCURRED.

SITE LOCATION:

DIVISION: RED RIVER

SUB-DIVISION: HEREFORD

LINE SEGMENT: 7186

MILE POST: 598.2

BNSF DIG PERMIT

1. GRADING

THE CONTRACTOR SHALL SUBMIT A SITE PLAN WITH THE PROPOSED GRADING.

THE PLAN SHALL DEMONSTRATE POSITIVE DRAINAGE AWAY FROM AND

AROUND THE PROPOSED AND EXISTING BUILDINGS. THE PROPOSED FINISH

FLOOR SHALL BE SET A MINIMUM OF ONE FOOT ABOVE THE PROPOSED

GROUND ELEVATION, AS REQUIRED FOR POSITIVE DRAINAGE AND THE USE OF

SUITABLE EXCAVATED MATERIAL FOR A ZERO EXPORT. GRADE ALL FOUR

SIDES GRADUALLY TO BLEND IN WITH THE EXISTING EXPOSED SURFACES.

REMOVE/REPLACE EXISTING GRAVEL SURFACE AND REPAIR ANY DISTURBED

GRAVEL AREAS WITH FRESH AGGREGATE OF SIMILAR GRADATION AND TYPE

OF STONE. THE SITE PLAN WITH THE PROPOSED GRADING SHALL BE

SUBMITTED FOR APPROVAL TO BNSF PRIOR TO CONSTRUCTION.

2. WATER SERVICE

THE CONTRACTOR SHALL SUBMIT A SITE PLAN WITH THE PROPOSED GRADING.

THE PLAN SHALL DEMONSTRATE POSITIVE DRAINAGE AWAY FROM AND

AROUND THE PROPOSED AND EXISTING BUILDINGS. THE PROPOSED FINISH

FLOOR SHALL BE SET A MINIMUM OF EIGHT INCHES ABOVE THE PROPOSED

GROUND ELEVATION, AS REQUIRED FOR POSITIVE DRAINAGE AND THE USE OF

SUITABLE EXCAVATED MATERIAL FOR A ZERO EXPORT. GRADE ALL FOUR

SIDES GRADUALLY TO BLEND IN WITH THE EXISTING EXPOSED SURFACES.

REMOVE/REPLACE EXISTING GRAVEL SURFACE AND REPAIR ANY DISTURBED

GRAVEL AREAS WITH FRESH AGGREGATE OF SIMILAR GRADATION AND TYPE

OF STONE. THE SITE PLAN WITH THE PROPOSED GRADING SHALL BE

SUBMITTED FOR APPROVAL TO BNSF PRIOR TO CONSTRUCTION.

3. SANITARY SEWER SERVICE

THE NEW BUILDING SANITARY SEWER SERVICE SHALL BE CONNECTED TO

EXISTING SANITARY SEWER SYSTEM ONSITE. THE CONTRACTOR SHALL

SUBMIT A SITE PLAN WITH THE PROPOSED ROUTING, SIZE, MATERIAL, ETC. OF

THE SANITARY SERVICE LINE SHALL BE SUBMITTED FOR APPROVAL TO BNSF

PRIOR TO CONSTRUCTION. IN ADDITION, THE CONTRACTOR SHALL FIELD

VERIFY THE EXISTING LOCATION, SIZE, DEPTH, CONDITION AND MATERIAL OF

THE EXISTING SANITARY SEWER SYSTEM IN THE VICINITY OF PROPOSED

BUILDING AND INCLUDE ON THE SITE PLAN. THE CONTRACTORS' ENGINEER

PREPARING THE SITE PLAN SHALL DETERMINE THE CAPACITY OF THE EXISTING

SANITARY SYSTEM AND IF IT CAN HANDLE THE ADDITION OF THE NEW SERVICE.

4. GEOMETRIC LAYOUT

THE SITE PLAN SHALL CONTAIN SURVEY DATA TO PROVIDE HORIZONTAL AND

VERTICAL REFERENCES SUFFICIENT TO LOCATE ALL ASPECTS OF THE WORK.

THE SITE PLAN SHALL INCLUDE DIMENSIONS AND/OR COORDINATES THAT

COMPLETELY DESCRIBE THE EXISTING AND PROPOSED SITE CONDITIONS. GPS

REFERENCES IN THE APPROPRIATE STATE PLANE COORDINATE SYSTEM IS

PREFERRED. SURVEY DATA SUCH AS THE REFERENCE SYSTEM USED, GEOID,

POINT LIST, SURFACE MODEL , ETC. SHALL BE SUBMITTED WITH THE SITE

PLAN. CONTRACTOR SHALL FIELD VERIFY THE EXISTING LOCATION OF ALL

SURFACE FEATURES. DISCREPANCIES TO BE REPORTED PRIOR TO BEGINNING

WORK. THE SITE PLAN WITH THE PROPOSED GEOMETRIC LAYOUT AND SURVEY

DATA SHALL BE SUBMITTED FOR APPROVAL TO BNSF PRIOR TO

CONSTRUCTION.

5. BUILDING LOCATION

THE CONTRACTOR SHALL STAKE THE NEW BUILDING CORNERS PRIOR TO

STARTING CONSTRUCTION. BNSF REVIEW AND APPROVAL SHALL BE

REQUIRED DOCUMENTED PRIOR TO ANY WORK.

6. PROVIDE A TEMPORARY FENCE OR BARRICADE TO SEPARATE CONSTRUCTION

AREA ACTIVITIES FROM ONGOING BNSF OPERATIONS / TRACKS TO ELIMINATE

THE NEED FOR FLAGMAN SERVICES EXCEPT WHEN WORKING BETWEEN THE

TEMPORARY FENCE AND THE TRACKS.

7. INITIAL SITE DESIGN IS BASED ON LIMITED VERIFIED INFORMATION. THE

EXISTING CONDITIONS SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO

PROPOSAL SUBMITTAL. THIS INCLUDES UTILITY LOCATIONS, PAVEMENT

LOCATION, ETC. BIDDERS SHALL INCLUDE THE SERVICES OF CIVIL ENGINEERS,

SURVEYORS, GEOTECHNICAL CONSULTANTS, ETC. AS NECESSARY TO

COMPLETE THE DESIGN. AN ENGINEERING SITE PLAN SHALL BE SUBMITTED TO

BNSF PRIOR TO ANY WORK FOR APPROVAL.

8. TYPICAL ASPHALT PAVEMENT CROSS-SECTION SHALL BE 2" SURFACE COURSE,

2" BINDER COURSE, 12" OF

3

4

" AGGREG. W/ FINES (MECH. COMPACTED).

POTHOLES SHALL BE REPAIRED WITH A FULL-DEPTH SAWCUT AT LIMITS OF

REPAIR AND REPAIRED WITH THE TYPICAL ASPHALT CROSS-SECTION. TYPICAL

ASPHALT PAVEMENT CROSS-SECTION ALSO LOCATED AT BUILDING AND SITE

DEMOLITION AREAS AND PROPOSED BUILDING EXCAVATION.

9. A TOPOGRAPHIC SITE SURVEY HAS BEEN COMMISSIONED. A SITE SURVEY

COMPLETED BY A LICENSED LAND SURVEYOR OR ENGINEER DEPICTING

CURRENT SITE CONDITIONS WILL BE SUPPLIED TO THE CONTRACTOR. SEE

NOTE 4.

10. ALL GRAPHIC UTILITY INFORMATION SHOWN ON THE ARCHITECTURAL SITE

PLAN IS FOR REFERENCE ONLY. THE CONTRACTOR IS RESPONSIBLE FOR

DETERMINING LOCATIONS OF ALL UTILITIES THAT MAY BE IMPACTED BY THE

CONSTRUCTION OF THIS PROJECT.

SITE PLAN GENERAL NOTES

PARKING LIGHT POLE FIXTURES

A. THE CONTRACTOR'S ENGINEER SHALL PROPOSE

ADDITIONAL SITE LIGHTING TO PROVIDE A

DESIGN THAT MEETS THE BNSF REQUIREMENT OF

A MINIMUM OF ONE (1) FOOTCANDLE

THROUGHOUT THE PROPOSED PARKING AREA.

B. ALL CONDUITS SHALL BE GALVANIZED RIGID

STEEL, 3/4" MINIMUM TRADE SIZE, EXCEPT

WHERE NOTED OTHERWISE. PROPERLY

COAT FIELD CUT ENDS.

C. JUNCTION, OUTLET, AND PULL BOXES SHALL

BE SIZED IN ACCORDANCE WITH N.E.C.

ARTICLE 314. BOXES SHALL BE NEMA 3R.

D. UNLESS OTHERWISE NOTED, FIXTURE

MOUNTING DIMENSIONS SHOWN ABOVE

FINISHED FLOOR / GRADE ARE TO BOTTOM

OF LIGHT.

E. CIRCUITS SUPPLYING LINE TO NEUTRAL

LOADS SHALL HAVE DEDICATED NEUTRALS,

i.e. ONE NEUTRAL PER PHASE. NEUTRAL

CONDUCTORS SHALL HAVE TRACER STRIPE

ALONG ENTIRE LENGTH INDICATING

ASSOCIATED PHASE.

F. FIXTURES SHALL BE LABELED WITH CIRCUIT

NUMBER.

G. PROVIDE DUPLEX RECEPTACLES ON ALL

LIGHT POLE FIXTURES

A

SITE LIGHTING GENERAL NOTES

A

A

K-2032GREENWICHLAVATORYVITREOUS CHINA

XX

XX

X

X

X

X

X

X

X

XXXXXXXX

XX

XX

XX

XX

FPHB

FPHB

XX

X

X

X

XX

XX

XX

X X X X X X X X X

ET

D S

TO

RA

GE

A

RE

A

1

2

3

4

1

2

3

4

5

6

7

8

9

100A 100B

7

5

107 108 109 110 112

113B

113A

103A 104 105 106

114D

114E

114C

114B

114A

103B

16

20

20

20

20 20 20 20 20

8

SLO

PE

1:12

SLOPE

1:12

17

38

9

A201

8

A201

7

A201

7

A201

KIT

CH

EN

ET

TE

PROVIDE PLUMBED

WATER LINE FOR

COFFEE MACHINE

24

29

6

14

8 8

8 8 8 8 8

8

8

8

8

8

8

8

12

12

33

36

34

36

40

33

34

40

33

36 30

34

36 40

33

34

40

31

32

32

35

31

31

32

32

35

31

3

A201

1

A201

BREAK

ROOM

102

VESTIBULE

100

UNISEX

SHOWER

ROOM

104

MEN'S

RESTROOM

105

9

4

2

3

CORRIDOR

101

JANITOR'S

CLOSET

106

A201

5

6

33

36

13

37

32

34

30

36

31

4

272727

GARAGE /

STORAGE

114

28

24

23

24

23

24

23

TYE BREAK

ROOM

107

14'-5"

8'-10"

23'-8"

16'-4" 11'-6" 10'-5" 10'-5" 10'-5"

10'-5"

5'-11" 14'-6"

20'-0 1/2"

26

'-10

"

10'-8"

8'-9"

VESTIBULE

113

14'-5"

5'-0"

9'-8 1/2"

17'-9"

39'-11 1/2"8'-6 1/2"

4

5'-3"

14'-0" 12'-11"12'-6"

8'-9" 7'-6" 5'-5" 11'-4" 3'-5" 5'-0" 7'-11"

12'-9 1/2"

14'-3"

7'-6"10'-3"

5'-5"16'-3"

7'-1

1"

8'-7"

2'-0"

2

A201

35

TYE

OFFICE

108

SIGNAL

OFFICE

109

TRACK

OFFICE

110

2'-0"

8'-6 1/2"

40

40

40

16

10 10

18

4

MECHANICAL

ROOM

111

TELECOM

112

26

22

22

19

19

41

41

17 17 17 17

1717171717

A

B

C

D

1 2 3 4 5

48

'-0

" O

UT

-T

O-O

UT

F

OU

ND

AT

IO

N

16

'-0

"1

6'-0

"1

6'-0

"

91'-0" OUT-TO-OUT FOUNDATION

25'-0" 24'-0" 21'-0" 21'-0"

39

39

39

39

39

39

2'-10"4'-5"5'-3"

8'-6 1/2"

6'-9 1

/2"

15

15

11

3'-0"

5'-0"

2'-0"

14

14

14 14

38

38

38

39'-9" 30'-8"

10'-1"

5'-0"

21

8'-0" TALL CHAIN LINK FENCE

WITH SWING GATES

ICE BRIDGE FROM TELECOM

TOWER TO BUILDING

25

13'-9"

15'-0"

41

CROSS HATCH INDICATES

PARTITIONS TO BE FULL HEIGHT TO

THE UNDERSIDE OF THE ROOF

CONSTRUCTION ABOVE, TYPICAL

35

35

2'-0"

1

1

10'-2"

30

111

18

2-HR

RATED

WALL

2-HR

RATED

WALL

2-HR

RATED

WALL

TELECOM TOWER. COORDINATE W/ BNSF

TELECOM FOR PLACEMENT AND DESIGN

30

30

4

4

5'-1 1/2"

5'-1

1

/2

"5

'-1

1

/2

"

SLO

PE AW

AY

FRO

M BUILDING

1:48 M

AX

SLOPE AWAY

FROM BUILDING

1:48 MAX

SLOPE AWAY

FROM BUILDING

1:48 MAX

SLO

PE AW

AY

FRO

M BUILDING

1:48 M

AX

WOMEN'S

RESTROOM

103

10

Bar i

s one

inch

on

orig

inal

dra

win

g. If

not

one

inch

on

this

draw

ing,

adj

ust s

cale

s acc

ordi

ngly

.

DATENO. BY DESCRIPTION OF REVISIONS

SERVICE REQUISTION NO.:

STATE

PROJ. TYPE

STATION

FILENAME:

PROJ. DESC.

CHKD.

DES.

DRWN.

DESIGN FIRM PROJ. NO.

SHEET:

DRAWING NUMBER

OF

APPROVED

DRAWING DESC.

TX

FACILITIES

HEREFORD

ERIC JOHNSON13955.114

CONCEPTUAL DESIGN

14

11/5

/202

1Da

te P

lott

ed:

K:\a

-f\BN

SF\1

3955

091\

_Her

efor

d_TX

_Re

plac

emen

t Dep

ot\0

4_Pr

oduc

tion\

01_C

AD\0

2_Sh

eets

\HER

ETX-

2021

-B-0

-A10

0.dw

gFi

le P

ath:

EAL

MJM

EBJ

MEP

70952

FACILITIES ENGINEERING

4515 KANSAS AVE.

KANSAS CITY, KS. 66106

5151 Mochel Drive, Suite 205

Downers Grove, IL 60515

Phone 630 499-4110

Fax 630 499-4119

tkda.com

DESIGN FIRM PROJ. MGR.

0 11/9/21 EBJ 30% ISSUE FOR BID

0 4' 8'

Scale: 3/16" = 1'-0"

FLOOR PLAN - 4,368 SQ. FT.

1

SOUND ATTENUATION

HERETX-2021-B-0-A100.dwg

FLOOR PLAN

A100

3

FREEZE PROOF WALL HYDRANT IN RECESSED BOX

W/ HOSE CONNECTION. COORDINATE PLACEMENT

W/ RIBS OF METAL SIDING

24" W X 24" D X 12" H MOP SERVICE BASIN

MOP & BROOM HOLDER (3 HOLDERS W/ ONE

POSITIONED OVER MOP BASIN)

FLOOR DRAIN

FLOOR SINK

REFRIGERATOR

EXISTING ICE MACHINE: SUPPLY WATER FILTER FROM

MANUFACTURER & ICE SCOOP

TRAFFIC BOLLARD W/ SAFETY YELLOW PLASTIC COVER

GAS WATER HEATER & RECIRCULATION PUMP

HIGH EFFICIENCY GAS FURNACE

CONC. EQUIPMENT PAD. PROVIDE FULL FOUNDATION PER LOCAL

FROST DEPTH / ORDINANCE. PROVIDE CONTROL JOINTS AS REQD.

LOCKERS : 18" WIDE X 21" DEEP X 72" TALL SINGLE

TIER LOCKERS - REFER TO DETAIL 3/202

ADA COMPLIANT SHOWER UNIT W/ SHOWER CURTAIN ROD &

ACCESSIBLE RINGS

CONCRETE STOOP / SIDEWALK / APRON / PATIO

HVAC CONDENSER UNIT

FLAT PANEL TV OR MONITOR: NOT IN CONTRACT.

PROVIDE POWER, DATA, AND BLOCKING IN PARTITION

DOWNSPOUT TIED INTO STORM DRAIN

4" CONCRETE HOUSEKEEPING PAD

GAS UNIT HEATER: CEILING MOUNTED

4'-0" x 4'-0" FIXED ALUMINUM WINDOW: PROVIDE BLINDS

CONDUIT TRENCH W/ FLUSH NON-SLIP METAL COVER PLATE

SEMI-RECESSED FIRE EXTINGUISHER CABINET

BUILT-IN WORKSTATION W/ PLASTIC LAMINATE COUNTERTOP

W/ BACK SPLASH & SIDE SPLASHES, PROVIDE (1) GROMMET PER DATA

PORT, REFER TO SHEET A300

UPPER CABINETS / SHELVES

MINI-SPLIT CONDENSER

DUCTLESS MINI-SPLIT INDOOR UNIT, WALL-MOUNTED

ADA STANDARD IDENTIFICATION SIGNAGE

COPIER MACHINE / PRINTER: NOT IN CONTRACT

MICROWAVE

SANITARY NAPKIN DISPOSAL CONTAINER

SOAP DISPENSER

24" W X 36" H FIXED POSITION TILT MIRROR

TOILET SEAT COVER DISPENSER

TOILET PAPER DISPENSER

PAPER TOWEL DISPENSER

GRAB BAR

MOUNTED HOOK

3'-0" ROOF OVERHANG

WATER PALLET STORAGE

VENDING MACHINE: NOT IN CONTRACT

FIRE EXTINGUISHER: SURFACE MOUNTED

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

18

17

19

20

22

23

24

25

26

27

28

30

31

32

33

34

35

29

KEY NOTES

LEGEND

FLOOR DRAIN

FLOOR SINK

FROST PROOF HOSE BIB

36

37

38

39

40

41

REFER TO SPECIFICATIONS

FOR ADDITIONAL INFORMATIO N

21

PROVIDE 2” SOUND ATTENUATION BLANKETS BETWEEN STUDS AT

PARTITIONS ISOLATING SENSITIVE OR LOUD ACTIVITIES AT THE

FOLLOWING LOCATIONS:

TYE BREAK ROOM 107

TYE OFFICE 108

SIGNAL OFFICE 109

TRACK OFFICE 110

ALL RESTROOMS & SHOWER ROOMS

FPHB

20

K-2032GREENWICHLAVATORYVITREOUS CHINA K-2032GREENWICHLAVATORYVITREOUS CHINA

60'-0"

11'-9"

11'-9"

23'-6"

1 2 3 4 5 6 7 8 9 10 11

12 13 14 15 16

COMMON AREA

100

3

UNISEX

SHOWER

100

TOILET

102

TOILET

103

OFFICE

104

OFFICE

107

JANITOR

106

TELECOM

105

1

17

17

17

17

17

17

17

17

18 18 18 18 18 18

18 18 18 18 18 18

19 19

18

18

18

18

18

26

26

2

8

7

KIT

CH

EN

ET

TE

555

5

6

6

9

101010

11

12

13

22

16

14

16

15

11

12

13

22

16

14

16

15

28

24

21

24

22

23

27

4

4

4

DN

RAMP DN

DN

25

29

21

1:12 MAX SLOPE

MEETING ADA GUIDELINES

1:12 MAX SLOPE

MEETING ADA GUIDELINES

10

Bar i

s one

inch

on

orig

inal

dra

win

g. If

not

one

inch

on

this

draw

ing,

adj

ust s

cale

s acc

ordi

ngly

.

DATENO. BY DESCRIPTION OF REVISIONS

SERVICE REQUISTION NO.:

STATE

PROJ. TYPE

STATION

FILENAME:

PROJ. DESC.

CHKD.

DES.

DRWN.

DESIGN FIRM PROJ. NO.

SHEET:

DRAWING NUMBER

OF

APPROVED

DRAWING DESC.

TX

FACILITIES

HEREFORD

ERIC JOHNSON13955.114

CONCEPTUAL DESIGN

14

11/5

/202

1Da

te P

lott

ed:

K:\a

-f\BN

SF\1

3955

091\

_Her

efor

d_TX

_Re

plac

emen

t Dep

ot\0

4_Pr

oduc

tion\

01_C

AD\0

2_Sh

eets

\HER

ETX-

2021

-B-0

-A10

1.dw

gFi

le P

ath:

EAL

MJM

EBJ

MEP

70952

FACILITIES ENGINEERING

4515 KANSAS AVE.

KANSAS CITY, KS. 66106

5151 Mochel Drive, Suite 205

Downers Grove, IL 60515

Phone 630 499-4110

Fax 630 499-4119

tkda.com

DESIGN FIRM PROJ. MGR.

0 11/9/21 EBJ 30% ISSUE FOR BID

0 4' 8'

Scale: 3/16" = 1'-0"

TEMPORARY MODULAR UNIT FLOOR PLAN - 1,410 SQ. FT.

1

HERETX-2021-B-0-A101.dwg

TEMPORARY MODULAR UNIT FLOOR PLAN

A101

4

LOCKERS: 18" WIDE X 21" DEEP X 72" TALL

REFRIGERATOR

MICROWAVE

4" CONCRETE PAD

WINDOW: PROVIDE BLINDS

BUILT-IN WORKSTATION WI/ PLASTIC LAMINATE COUNTERTOP

W/ BACK SPLASH & SIDE SPLASHES: PROVIDE (1) GROMMET

PER DATA PORT

SOLID SURFACE COUNTER TOP W/ BACK SPLASH & SIDE

SPLASHES

UPPER CABINETS / LOWER CABINETS

WATER CLOSET WATER ISOLATION VALVE (QUARTER-TURN)

RECESSED IN WALL W/ PAINTED STEEL ACCESS PANEL

ADA STANDARD IDENTIFICATION SIGNAGE

24" W X 36" H FIXED POSITION TILT MIRROR

SOAP DISPENSER

PAPER TOWEL DISPENSER

TOILET SEAT COVER DISPENSER

TOILET PAPER DISPENSER

GRAB BAR

EXECUTIVE CHAIR

BREAK ROOM CHAIR

BREAK ROOM TABLE

ADA BENCH: 42" LONG X 20" WIDE X 17.5" HIGH

ELECTRICAL PANEL

FLOOR DRAIN

24" W X 24" D X 12" H MOP SERVICE BASIN

SEMI-RECESSED FIRE EXTINGUISHER CABINET

MOUNTED HOOK

U-SHAPED DESK

COPIER MACHINE / PRINTER: NOT IN CONTRACT

ADA COMPLIANT SHOWER UNIT W/ SHOWER CURTAIN ROD &

ACCESSIBLE RINGS

MOP & BROOM HOLDER (3 HOLDERS W/ ONE

POSITIONED OVER MOP BASIN)

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

18

17

19

20

22

23

24

KEY NOTES

REFER TO SPECIFICATIONS

FOR ADDITIONAL INFORMATIO N

21

25

26

LEGEND

DATA J-BOX W/ 1" CONDUIT

DUPLEX POWER OUTLET

DUPLEX GFI RECEPTACLE MOUNTED 6" ABOVE COUNTER

DUPLEX RECEPTACLE MOUNTED 6" ABOVE COUNTER

27

28

29

83 2

1

2

4

5

2

2

6 112 1 19

10

1 7

1

8 126 10

1 2 3 4 5

13

13

14

1

10

107

1

1 1

1

1

8

2

3

5

C B AD

13

13

4

10

14

2

1

4

21122

8

12345

1

2

13 13

10 10

5

3

CBA D

1

4 10

8

6

1

2

7

9

6 1

3

5

14

13

13

10

Bar i

s one

inch

on

orig

inal

dra

win

g. If

not

one

inch

on

this

draw

ing,

adj

ust s

cale

s acc

ordi

ngly

.

DATENO. BY DESCRIPTION OF REVISIONS

SERVICE REQUISTION NO.:

STATE

PROJ. TYPE

STATION

FILENAME:

PROJ. DESC.

CHKD.

DES.

DRWN.

DESIGN FIRM PROJ. NO.

SHEET:

DRAWING NUMBER

OF

APPROVED

DRAWING DESC.

TX

FACILITIES

HEREFORD

ERIC JOHNSON13955.114

CONCEPTUAL DESIGN

14

11/5

/202

1Da

te P

lott

ed:

K:\a

-f\BN

SF\1

3955

091\

_Her

efor

d_TX

_Re

plac

emen

t Dep

ot\0

4_Pr

oduc

tion\

01_C

AD\0

2_Sh

eets

\HER

ETX-

2021

-B-0

-A20

0.dw

gFi

le P

ath:

EAL

MJM

EBJ

MEP

70952

FACILITIES ENGINEERING

4515 KANSAS AVE.

KANSAS CITY, KS. 66106

5151 Mochel Drive, Suite 205

Downers Grove, IL 60515

Phone 630 499-4110

Fax 630 499-4119

tkda.com

DESIGN FIRM PROJ. MGR.

0 11/9/21 EBJ 30% ISSUE FOR BIDHERETX-2021-B-0-A200.dwg

0 8' 16'

Scale: 1/8" = 1'-0"

NORTH ELEVATION

4

0 8' 16'

Scale: 1/8" = 1'-0"

SOUTH ELEVATION

1

0 8' 16'

Scale: 1/8" = 1'-0"

WEST ELEVATION

3

0 8' 16'

Scale: 1/8" = 1'-0"

EAST ELEVATION

2

EXTERIOR ELEVATIONS

A200

5

TRAFFIC BOLLARD W/ SAFETY YELLOW PLASTIC COVER

PRE-FINISHED DOWNSPOUT TIED INTO STORM DRAIN.

PRE-FINISHED 22 GAUGE STANDING SEAM METAL ROOF

PRE-FINISHED 26 GAUGE 1 1/2" RIBBED METAL SIDING

PRE-FINISHED CONTINUOUS METAL FASCIA / GUTTER - FINISH

PAINT TO MATCH TRIM COLOR .

HVAC CONDENSER UNIT

CONCRETE EQUIPMENT PAD, PROVIDE CONTROL JOINTS

AS REQUIRED

WALL-MOUNTED LED LIGHT FIXTURE ON PHOTOCELL

CONTROL

ELECTRICAL DISCONNECT SWITCHES MOUNTED ON

ALUMINUM EQUIPMENT RACK SUPPORTED BY UNISTRUTS

PRE-FINISHED METAL TRIM - FINISH PAINT TO MATCH TRIM

COLOR

FREEZE PROOF WALL HYDRANT IN RECESSED BOX

W/ HOSE CONNECTION. COORDINATE PLACEMENT

W/ RIBS OF METAL SIDING.

ELECTRICAL DISCONNECT SWITCH FOR MINI-SPLIT

CONDENSER

SECURITY CAMERA BY OWNER. CONTRACTOR TO PROVIDE

JUNCTION BOX AND CONDUIT. COORDINATE INSTALL W/

BNSF TELECOM.

FUTURE TELECOM TOWER. COORDINATE W/ BNSF TELECOM.

1

3

4

6

7

8

9

10

11

KEY NOTES

REFER TO SPECIFICATIONS

FOR ADDITIONAL INFORMATIO N

2

12

5

13

14

AS SCHEDULED

CEILING HT.

EL. 100'-0"

FIN. FLOOR

AS SCHEDULED

CEILING HT.

EL. 100'-0"

FIN. FLOOR

WPS AS SCHEDULED, TYP.

K-4329KINGSTONC_TOILETSVITREOUS CHINA

K-4329KINGSTONC_TOILETSVITREOUS CHINA

AS SCHEDULED

CEILING HT.

EL. 100'-0"

FIN. FLOOR

MIRROR

PAPER TOWEL

DISPENSER

WALL-MOUNTED

LAVATORY

4" VINYL BASE

WATER CLOSETTOILET TISSUE

DISPENSER

TOILET SEAT COVER

DISPENSER

TOILET PARTITION

GRAB BARS

URINAL, TYP.

TOILET TISSUE

DISPENSER

WPS AS SCHEDULED, TYP.

K-4329KINGSTONC_TOILETS VITREOUS CHINA

K-4329KINGSTONC_TOILETSVITREOUS CHINA

AS SCHEDULED

CEILING HT.

EL. 100'-0"

FIN. FLOOR

WATER CLOSET TOILET TISSUE

DISPENSER

TOILET SEAT COVER

DISPENSER

TOILET PARTITION

GRAB BARS

TOILET TISSUE

DISPENSER

MIRROR

PAPER TOWEL

DISPENSER

WALL-MOUNTED

LAVATORY

4" VINYL BASE

WPS AS SCHEDULED, TYP. WPS AS SCHEDULED, TYP.

4" VINYL BASE

METAL LOCKERS,

SEE DETAIL 10/A201

METAL LOCKERS,

SEE DETAIL 10/A201

SOAP DISPENSER

SOAP DISPENSER

SANITARY

NAPKIN

DISPENSER

SANITARY NAPKIN

DISPENSER

SANITARY NAPKIN

DISPENSER

SANITARY NAPKIN

DISPENSER

KNEE

SPACE

AS SCHEDULED

CEILING HT.

EL. 100'-0"

FIN. FLOOR

4" VINYL BASE

WPS AS SCHEDULED,

TYP.

PAINTED GYP. BD.

12" D P. LAM. WALL

CABINETS

REFRIGERATOR

VENDING MACHINE, N.I.C.

4" VINYL BASE @ TOE KICK

P. LAM. BASE CABINETS

1" FILLER STRIP

SOLID SURFACE COUNTERTOP,

BACK SPLASH & SIDE SPLASH

2'-1

0"1'

-8"

2'-6

"

2'-2

"

3'-0" 3'-0" 3'-0"

MICROWAVE

K-4329KINGSTONC_TOILETSVITREOUS CHINA

AS SCHEDULED

CEILING HT.

EL. 100'-0"

FIN. FLOOR

PRE-FABRICATED

ACCESSIBLE

SHOWER UNIT

W/ GRAB BARS

AND FOLDING BENCH

WPS AS SCHEDULED,

TYP.

SHOWER CURTAIN

4" VINYL BASE

WATER CLOSET

TOILET TISSUE

DISPENSER

TOILET SEAT COVER

DISPENSER

GRAB BAR

GRAB BARS

AS SCHEDULED

CEILING HT.

EL. 100'-0"

FIN. FLOOR

WATER CLOSET

GRAB BARS

WPS AS SCHEDULED,

TYP.

MIRROR

PAPER TOWEL

DISPENSER

WALL-MOUNTED

LAVATORY

4" VINYL BASE

SOAP DISPENSER

SANITARY NAPKIN

DISPENSER

TOILET TISSUE

DISPENSER

SANITARY

NAPKIN

DISPENSER

2'-6

"2'

-0"

2'-6

"

AS SCHEDULED

CEILING HT.

EL. 100'-0"

FIN. FLOOR

2'-6

"2'

-0"

2'-6

"

AS SCHEDULED

CEILING HT.

EL. 100'-0"

FIN. FLOOR

1" FILLER STRIP, TYP.

24" D P. LAM. COUNTERTOP,

BACK SPLASH & SIDE SPLASH

12" D X 42" W / P. LAM.

LOCKING WALL CABINET

AT EACH END OF PARTITION

WALL-MOUNTED COUNTER

BRACKET: RAKKS EH SURFACE

MOUNT (OR APPROVED EQUAL)

AT 3'-0" O.C. MAX

12" D P. LAM. OPEN SHELF

UNIT W/ ADJUSTABLE

MIDDLE SHELF

PAINTED GYP. BD.

1" FILLER STRIP, TYP.

24" D P. LAM. COUNTERTOP,

BACK SPLASH & SIDE SPLASH

12" D X 36" W / P. LAM.

LOCKING WALL CABINET

TYP. OF 3

WALL-MOUNTED COUNTER

BRACKET: RAKKS EH SURFACE

MOUNT (OR APPROVED EQUAL)

AT 3'-0" O.C. MAX

PAINTED GYP. BD.

4" VINYL BASE4" VINYL BASE

18"

FRONT

21"

6"

6'-0"

TY

P.

SIDE

6"

TY

P.

SOLID SURFACE SILL, TYP.

ALUMINUM NUMBER

PLATE, TYP.

LOUVERS @

TOP / BOT., TYP.

WARDROBE HOOKS

TYP.

SHELF & COAT ROD,

TYP.

BUILT-IN HANDLE,

TYP.

FINISHED END PANEL,

TYP.

METAL ZEE BASE

PROVIDED BY

LOCKER MFR., TYP.

CEILING AS

SCHEDULED

METAL FINISHED END PANEL

BY LOCKER MFR., TYP

INDIVIDUAL CLOSED METAL

BASE PLATE PROVIDED BY

LOCKER MFR., TYP.

SLOPED HOOD, TYP.

HERETX-2021-B-0-A201.dwg

INTERIOR ELEVATIONS

6

0 4' 8'

Scale: 1/4" = 1'-0"

WOMEN'S RESTROOM 103 - EAST

1

A201

10

Bar i

s one

inch

on

orig

inal

dra

win

g. If

not

one

inch

on

this

draw

ing,

adj

ust s

cale

s acc

ordi

ngly

.

DATENO. BY DESCRIPTION OF REVISIONS

SERVICE REQUISTION NO.:

STATE

PROJ. TYPE

STATION

FILENAME:

PROJ. DESC.

CHKD.

DES.

DRWN.

DESIGN FIRM PROJ. NO.

SHEET:

DRAWING NUMBER

OF

APPROVED

DRAWING DESC.

TX

FACILITIES

HEREFORD

ERIC JOHNSON13955.114

CONCEPTUAL DESIGN

14

11/5

/202

1Da

te P

lott

ed:

K:\a

-f\BN

SF\1

3955

091\

_Her

efor

d_TX

_Re

plac

emen

t Dep

ot\0

4_Pr

oduc

tion\

01_C

AD\0

2_Sh

eets

\HER

ETX-

2021

-B-0

-A20

1.dw

gFi

le P

ath:

EAL

MJM

EBJ

MEP

70952

FACILITIES ENGINEERING

4515 KANSAS AVE.

KANSAS CITY, KS. 66106

5151 Mochel Drive, Suite 205

Downers Grove, IL 60515

Phone 630 499-4110

Fax 630 499-4119

tkda.com

DESIGN FIRM PROJ. MGR.

0 11/9/21 EBJ 30% ISSUE FOR BID

0 4' 8'

Scale: 1/4" = 1'-0"

WOMEN'S RESTROOM 103 - WEST

2

0 4' 8'

Scale: 1/4" = 1'-0"

MEN'S RESTROOM 105 - WEST

3

0 4' 8'

Scale: 1/4" = 1'-0"

MEN'S RESTROOM 105 - EAST

4

0 4' 8'

Scale: 1/4" = 1'-0"

BREAK ROOM 102 (KITCHENETTE) - EAST

9

0 4' 8'

Scale: 1/4" = 1'-0"

UNISEX SHOWER ROOM 104 - NORTH

5

0 4' 8'

Scale: 1/4" = 1'-0"

UNISEX SHOWER ROOM 104 - EAST

6

0 4' 8'

Scale: 1/4" = 1'-0"

OFFICE 109 AND 110 (BUILT-IN WORKSTATION)

7

0 4' 8'

Scale: 1/4" = 1'-0"

OFFICE 108 (BUILT-IN WORKSTATION)

8

0 4' 8'

Scale: 1/4" = 1'-0"

TYPICAL SINGLE TIER LOCKER

10

6"

8"

3'

6"

SEE DOOR

SCHEDULE

SE

E D

OO

R S

CH

ED

UL

E

C

TEMPERED

HALF LITE

GLASS

D

SEE DOOR

SCHEDULE

SEE D

OO

R SC

HED

ULE

VINYL BASE @ TOE KICK

4"

4"

ADJUSTABLE SHELF,

1

2

" CORE MATERIAL

1

4

"x4" WIRE PULLS. - FINISH

TO MATCH SPEC.

1'-1

0 1

/2

"

SOLID SURFACE COUNTERTOP AND

BACKSPLASH WITH RETURN AT

SIDE WALL, SCRIBE TO WALL

6"

1 1

/2

"

4" DEEP DRAWER w/ METAL

SLIDES &

1

4

"x4" WIRE PULLS.

2'-1

0"

3'-2

"

NOTE:

BASE CABINETS BUILT ENTIRELY OF A FINISH

WOOD MATERIAL (ALL SURFACES).

2' 1"

SEE DOOR

SCHEDULE

6"

8"

KICK PLATE

WHERE

SCHEDULED

2'

SE

E D

OO

R S

CH

ED

UL

E

SEE DOOR

SCHEDULE

SE

E D

OO

R S

CH

ED

UL

E

BA

TEMPERED

VISION

GLASS

DOOR STATION STRIKE RELEASE

(AL-1802C-2-2-01 18/2)

REQ (BELDEN 6441FE - 20-2PAIR)

DOOR CONTACT (BELDEN B88442 - 22/2)

LOCK POWER (AL-1802C-2-2-01 18/2)

READER DATA (ALPHA WIRE 58136 - 18-6C)

NOTE:

DOORS SHALL RECEIVE WIRING FOR

FUTURE CARD ACCESS READERS.

COORDINATE W/ BNSF TELECOM.

1'-4" 1'-4" 1'-4"

TWO LAYERS 5/8" THICK GYPSUM BOARD (UL TYPE SCX)

3-5/8" STEEL STUDS, SPACED 16' O.C.

3 1/2" GLASS FIBER BATT INSULATION W/ VAPOR BARRIER IN CAVITY

6 1/

8" NOTE: STUD GAUGE

TO BE DETERMINED BY

CONTRACTOR'S

ENGINEER OF RECORD

TO SPAN FULL HEIGHT

TO UNDERSIDE OF

ROOF DECK.

3'-6

"

6"

3'-0

"

2'-0"

SAFETY YELLOW HDPE

BOLLARD COVER SLEEVE

W/ DOMED TOP AND

REFLECTIVE TAPE

SHOP-PRIMED 6" DIA.

SCH 40 MIN. STEEL

PIPE FILLED W/ CONC.

T/ GRADE

ERL.: VARIES

GRADE - SLOPE AWAY

FROM FOOTING

24" DIAMETER AUGERED

CONC. PIER - 3500 PSI

CONC. FOOTING. USE

SONOTUBE WHEN

EMBEDDED

1'

PROVIDE BLOCKING AS REQUIRED

FOR CABINET MOUNTING - VERIFY

w/ MANUFACTURER & INSTALLER

NOTE:

NO SHELF REQ'D. IN CABINETS 12" HIGH OR LESS

VA

RIE

S

RE

F. E

LE

VA

TIO

NS

4'-6"

A.F

.F

.

1

4

"x4" WIRE PULLS. - FINISH

TO MATCH SPEC.

ADJUSTABLE SHELF,

1

2

" CORE MATERIAL

NOTE:

WALL CABINETS BUILT ENTIRELY OF A FINISH

WOOD MATERIAL (ALL SURFACES). (REF. SPEC.)

MODELNUMBERTRADENAMEPRODUCTMATERIAL

VINYL BASE

1'-6"

5 1/2"

1 1/2"

PLUMBING NOTE:

USE STAINLESS STEEL SINK. USE

POLISHED CHROME GOOSENECK

FAUCET, ADA COMPLIANT, w/ SINGLE

LEVER ADA COMPLIANT CONTROL

(OFFSET FROM FAUCET)

2' 1"

1'-1"

2'-10"

3'-2"

SOLID SURFACE COUNTERTOP AND

BACKSPLASH WITH RETURN AT

SIDE WALL, SCRIBE TO WALL

REMOVABLE ACCESS PANEL

NOTE:

BASE CABINETS BUILT ENTIRELY OF A FINISH

WOOD MATERIAL (ALL SURFACES).

9"

8"3"

6"

ANGLE BRACKET w/ Z-CLIPS

ATTACHED TO CABINET BEYOND

TO HOLD ACCESS PANEL

BASE TRIM

PANEL CLOSURE

12

4

METAL LINER PANEL

TO 8'-0" A.F.F.

METAL STUDS

R-19 WALL INSULATION

26 GAUGE

FACTORY-FINISHED

METAL WALL PANELS

EL. 100'-0"

T/ FINISHED FLOOR

EL. 117'-1"

FRAMING EAVE

FLOORING AS SCHEDULED

3'-0"PRE-ENGINEERED

METAL BUILDING

FRAMING

R-19 OR CODE MIN. BATT

INSULATION @ METAL GIRTS W/

SMART VAPOR BARRIER

MIN. R-19 BATT INSULATION

BETWEEN 6" METAL STUDS

@ 16" O.C. MIN. W/ METAL

LINER PANELS

FIXED ALUMINUM WINDOW

(SEE PLAN)

SOLID SURFACE

WINDOW STOOL

MIN. R-19 BATT INSULATION

BETWEEN 6" METAL STUDS @

16" O.C. MIN. W/ 5/8" GYPSUM

BOARD INTERIOR FINISH

BASE TRIM

6" REINFORCED CONC. SLAB

ON COMPACTED SUB-GRADE

OVER 15 MIL VAPOR BARRIER

WALL BASE AS SCHEDULED

MIN. 6 MIL VAPOR BARRIER

6" SILL RUNNER TRACK

ANCHORED TO FOUNDATION

WINDOW BASE FLASHING

CLOSURE

FLOORING AS SCHEDULED

PANEL CLOSURE

INSIDE CLOSURE

6" CONC. SIDEWALK WITH

WWF REINFORCEMENT -

SLOPE AWAY FROM

BUILDING. MAINTAIN

SEPARATION FROM BASE

OF METAL WALL PANELS

AND SLOPE UP TO MEET

EXTERIOR MAN DOORS

DOWNSPOUT BEYOND

12

4

EL. 100'-0"

T/ FINISHED FLOOR

3'-0"

ACT CEILING TILES W/

METAL GRID

PRE-ENGINEERED

METAL BUILDING

FRAMING

PROVIDE 1" HORIZ.

MINIBLINDS AT ALL

EXTERIOR WINDOWS

R-19 OR CODE MIN. BATT

INSULATION @ METAL GIRTS W/

SMART VAPOR BARRIER

GIRT

PRE-FINISHED 22 GAUGE STANDING

SEAM METAL ROOF

R-38 OR CODE MIN. BATT INSULATION

AT ROOF W/ SMART VAPOR BARRIER /

FALL PROTECTION

PRE-FINISHED METAL SOFFIT

PANEL EAVE CLOSURE

PRE-FINISHED CONTINUOUS

METAL FASCIA / GUTTER -

PROVIDE HEAT TRACING IN

GUTTER - TRIM PAINT COLOR

SNOW GUARD

PRE-FINISHED

DOWNSPOUT - PROVIDE HEAT

TRACING IN DOWNSPOUT, TYP.

EL. 117'-1"

FRAMING EAVE

EL. 103'-2"

WINDOW SILL

EL. 107'-2"

WINDOW HEAD

PROVIDE PERIMETER INSULATION

AS REQUIRED BY ENERGY CODE

OR LOCAL DESIGN PRACTICE

FOUNDATION DESIGN BY G.C.'S

STRUCTURAL AND GEOTECHNICAL

ENGINEERS. FOUNDATION DEPTH

TO BE BASED ON LOCAL MUNICIPAL

CODE

EL. 109'-4"

WALL GIRT

10

Bar i

s one

inch

on

orig

inal

dra

win

g. If

not

one

inch

on

this

draw

ing,

adj

ust s

cale

s acc

ordi

ngly

.

DATENO. BY DESCRIPTION OF REVISIONS

SERVICE REQUISTION NO.:

STATE

PROJ. TYPE

STATION

FILENAME:

PROJ. DESC.

CHKD.

DES.

DRWN.

DESIGN FIRM PROJ. NO.

SHEET:

DRAWING NUMBER

OF

APPROVED

DRAWING DESC.

TX

FACILITIES

HEREFORD

ERIC JOHNSON13955.114

CONCEPTUAL DESIGN

14

11/5

/202

1Da

te P

lott

ed:

K:\a

-f\BN

SF\1

3955

091\

_Her

efor

d_TX

_Re

plac

emen

t Dep

ot\0

4_Pr

oduc

tion\

01_C

AD\0

2_Sh

eets

\HER

ETX-

2021

-B-0

-A20

2.dw

gFi

le P

ath:

EAL

MJM

EBJ

MEP

70952

FACILITIES ENGINEERING

4515 KANSAS AVE.

KANSAS CITY, KS. 66106

5151 Mochel Drive, Suite 205

Downers Grove, IL 60515

Phone 630 499-4110

Fax 630 499-4119

tkda.com

DESIGN FIRM PROJ. MGR.

0 11/9/21 EBJ 30% ISSUE FOR BIDHERETX-2021-B-0-A202.dwg

WALL SECTIONS AND SCHEDULES

A202

7

0 2' 4'

Scale: 3/4" = 1'-0"

TYPICAL WALL SECTION @ OFFICES

1

GROUP 1

HINGES, LOCKSET, CLOSER, KICKPLATE, THRESHOLD, OVERHEAD

STOP, WEATHERSEAL KIT, 24V ELECTRIC STRIKE AND CARD READER

GROUP 2

HINGES, PUSH/PULLS, KICKPLATE, CLOSER, WALL STOP

GROUP 3

HINGES, LOCKSET, WALL STOP

GROUP 4

HINGES, PRIVACY LOCKSET, KICKPLATE, WALL STOP

GROUP 5

HINGES, LATCHSET, PANIC BAR, CLOSER, KICKPLATE, THRESHOLD,

OVERHEAD STOP, WEATHERSEAL KIT

GROUP 6

HINGES, LOCKSET, PANIC BAR, CLOSER, THRESHOLD, OVERHEAD STOP,

WEATHERSEAL KIT, 24V ELECTRIC STRIKE AND CARD READER

GROUP 7

HINGES, LOCKSET, PANIC BAR, CLOSER, WALL STOP, KICKPLATE, 24V

ELECTRIC STRIKE AND CARD READER

GROUP 8

HINGES, LOCKSET, CLOSER, WALL STOP, 24V ELECTRIC STRIKE AND

CARD READER

HARDWARE SCHEDULE

0 2' 4'

Scale: 3/4" = 1'-0"

TYPICAL WALL SECTION @ GARAGE SPACE

2

ROOM FINISH SCHEDULE

ID. ROOM NAME FLOOR BASE

WALLS CEILING

REMARKS

100

101

102

103

106

104

105

107

108

109

110

113

112

111

VESTIBULE

PT: PAINTGB: GYPSUM BOARD CONC-S: SEALED CONCRETE

WPS: WALL PROTECTION SYSTEM

ACT: ACOUSTICAL CEILING TILE

VB: VINYL BASE

LEGEND

PLYWD: PLYWOOD GRADE AC

FULL HEIGHT WPS4" VB WPS - 8'-0"

VCT: VINYL COMPOSITION TILE

MAT FIN MAT FIN HT

MLP: METAL LINER PANEL RSF: NOT USED CPT: CARPET TILES

TELECOM PT/ PLYWD ACT -GB 10'-0"4" VB

CONT. PARTITIONS TO UNDERSIDE OF ROOF DECK

FIRE RESISTANT PAINT ON ALL WALLS

CPT RACT -

RACT: RADIANT ACOUSTICAL CEILING TILE

CONC-S

CORRIDOR 4" VB GB/WPS PT 9'-0"ACT -CPT 4' WPS WAINSCOT

BREAK ROOM 4' WPS WAINSCOTACT4" VB GB/WPS PT -CPT 9'-0"

FULL HEIGHT WPSGB4" VB WPS - 8'-0"PTVCTWOMEN'S RESTROOM

JANITOR'S CLOSET CONC-S 4" VB 4' WPS WAINSCOT AT WET WALLS OF MOP SINKGB/WPS PT 9'-0"PT GB

UNISEX SHOWER ROOM FULL HEIGHT WPSGB4" VB WPS - 8'-0"PTVCT

MEN'S RESTROOM FULL HEIGHT WPSGB4" VB WPS - 8'-0"PTVCT

TYE BREAK ROOM

TRACK OFFICE

SIGNAL OFFICE

TYE OFFICE

VESTIBULE FULL HEIGHT WPS4" VB WPS - 8'-0"CPT RACT -

MECHANICAL ROOM CONC-S GB - - -PT CONT. PARTITIONS TO UNDERSIDE OF ROOF DECK4" VB

4' WPS WAINSCOTACT4" VB GB/WPSCPT 9'-0"

4' WPS WAINSCOTACT4" VB GB/WPSCPT 9'-0"

4' WPS WAINSCOTACT4" VB GB/WPSCPT 9'-0"

4' WPS WAINSCOTACT4" VB GB/WPSCPT 9'-0"

114

-

GARAGE / STORAGE CONC-S GB/MLP- - - -PT CONT. PARTITIONS TO UNDERSIDE OF ROOF DECK

DOOR SCHEDULE

100A

ID. SIZE MAT'L. TYPE

DOOR

HDWR.

GROUP

REMARKS

FRAME

MAT'L

100B

3'-0" x 7'-0"

3'-0" x 7'-0"

INSULATE

INSULATE

ALUM

HM

ALUM

HM

C

C

5

7

GENERAL NOTES:

1. ALL DOORS, INCLUDING GLAZING AND HARDWARE, WITHIN RATED PARTITIONS SHALL

BEAR THE EQUIVALENT FIRE RATING LABEL IN ORDER TO MAINTAIN THE REQUIRED FIRE

RATING OF THE SYSTEM.

103A

103B

3'-0" x 7'-0"

3'-0" x 7'-0"

HM HMA 2 --

HM HMA 2 --

3'-0" x 7'-0" HM HMA 4 --104

105 3'-0" x 7'-0" HM HMA 2 --

3'-0" x 7'-0" HM HM 3A KICKPLATE106

107

108

109

110

3'-0" x 7'-0" HM HMB -3

3'-0" x 7'-0" HM HMB -3

3'-0" x 7'-0" HM HMB -3

3'-0" x 7'-0" HM HMB -3

111

112 3'-0" x 7'-0" HM HMA 8 -

6'-0" x 7'-0" HM HMA

INSULATE - SURFACE MOUNT

FLUSH BOLTS AT HEAD & SILL

1

113A

113B

3'-0" x 7'-0"

3'-0" x 7'-0"

INSULATE

INSULATE

ALUM

HM

ALUM

HM

C

C

5

7

114A

114B

114C

114D

114E

8'-0" x 8-0" STEEL STEEL- - INSULATE

12'-0" x 14-0" STEEL STEEL- - INSULATE

3'-0" x 7'-0" HM HMA 8 -

3'-0" x 7'-0" INSULATEALUM ALUMA 1

3'-0" x 7'-0" INSULATEHM HMA 1

-

-

-

-

PT

PT

PT

PT

0 2' 4'

Scale: 3/4" = 1'-0"

TYPICAL WALL CABINET

8

0 2' 4'

Scale: 3/4" = 1'-0"

TYPICAL BASE CABINET

6

0 2' 4'

Scale: 3/4" = 1'-0"

TYPICAL SINK CABINET

7

0 2' 4

Scale: 1/2" = 1'-0"

PIPE BOLLARD

5

0 1' 2'

Scale: 1" = 1'-0"

TWO HOUR RATED WALL (UL DESIGN NO. U419)

3

0 2' 4

Scale: 1/2" = 1'-0"

CARD ACCESS CABLE PLACEMENT - TYP.

4

DOOR TYPES

K-2032GREENWICHLAVATORYVITREOUS CHINA

XX

XX

X

X

X

X

X

X

X

XXXXXXXX

XX

XX

XX

XX

FPHB

FPHB

XX

X

X

X

XX

XX

XX

X X X X X X X X X

J

J

J

J

C

C

C

C C

C

CC

C

C

C

C

C

C

C

C

J

J

J

1

1

1

1

1

1

1

2 2 2

2 2 2

3

2

2

2

3

2

2

2

2

2

2

3

2

2

2

BREAK

ROOM

102

VESTIBULE

100

UNISEX

SHOWER

ROOM

104

WOMEN'S

RESTROOM

103

MEN'S

RESTROOM

105

CORRIDOR

101

GARAGE /

STORAGE

114

TYE BREAK

ROOM

107

VESTIBULE

113

TYE

OFFICE

108

SIGNAL

OFFICE

109

TRACK

OFFICE

110

MECHANICAL

ROOM

111

TELECOM

112

5

5

9

6

A

B

C

D

1 2 3 4 5

2

11

6

10

4

4

4

8

TELECOM TOWER W/ CAMERA MOUNTED AT

40'-0" ABOVE GRADE LOOKING NORTH

PROVIDE GROUND BAR IN

TELECOM ROOM W/ INDIVIDUAL

GROUND CONNECTION TO

GROUND BAR FROM GROUND

GRID PER BNSF ELECTRICAL

GUIDELINES

PROVIDE RECEPTACLES FOR TWO

(2) DEDICATED 240V L6-30 AMP

CIRCUITS AT 96" A.F.F. VERIFY

PLACEMENT OF RECEPTACLES W/

BNSF TELECOM PRIOR TO

INSTALLATION.

DISCONNECT SWITCH FOR MINI-SPLIT

CONDENSER MOUNTED ON WALL

9

JANITOR'S

CLOSET

106

7

EXECUTIVE CHAIR

TRAINING / READY ROOM CHAIR

TRAINING / READY ROOM TABLE

ELECTRICAL PANEL

PROVIDE RECESSED DUPLEX POWER & DATA W/ BLOCKING

FOR WALL MOUNTED MONITOR @ 7'-6" A.F.F.

TELECOM CABLE TRAY (ABOVE CEILING): COOPER

B LINE CABLE TRAY SYSTEM, FT4X8X10, CABLE

RUNWAY WIRE MESH 10' L x 8" W x 4" D STRAIGHT

SECTIONS ELECTRO-GALVANIZED

DISCONNECT SWITCHES MOUNTED ON EQUIPMENT

RACK SUPPORTED BY UNISTRUTS

TRAFFIC RATED 30" X 60" X 30" HAND HOLE: PROVIDE THREE (3) BURIED,

EMPTY 2" CONDUITS FROM TELECOM ROOM TO HAND HOLE AND

PROVIDE THREE (3) BURIED, EMPTY 2" CONDUITS TO EXISTING FIBER

LINE. COORDINATE W/ BNSF TELECOM PRIOR TO INSTALLATION.

PROVIDE COILED-UP CAT6 CABLE IN CABLE TRAY FOR

WIRELESS ACCESS POINT (WAP) BY OTHERS

SERVER RACK: NOT IN CONTRACT

TERMINATE CABLE TRAYS 3' FROM EACH FACE OF PARTITION

WHERE TRAY INTERFACES FULL-HEIGHT PARTITIONS AND

INSTALL ONE (1) HILTI 4" SPEED SLEEVE THROUGH PARTITION

IN LINE CABLE TRAY AND FIRE SEAL PENETRATION - TYP

1

2

3

4

5

6

7

10

Bar i

s one

inch

on

orig

inal

dra

win

g. If

not

one

inch

on

this

draw

ing,

adj

ust s

cale

s acc

ordi

ngly

.

DATENO. BY DESCRIPTION OF REVISIONS

SERVICE REQUISTION NO.:

STATE

PROJ. TYPE

STATION

FILENAME:

PROJ. DESC.

CHKD.

DES.

DRWN.

DESIGN FIRM PROJ. NO.

SHEET:

DRAWING NUMBER

OF

APPROVED

DRAWING DESC.

TX

FACILITIES

HEREFORD

ERIC JOHNSON13955.114

CONCEPTUAL DESIGN

14

11/5

/202

1Da

te P

lott

ed:

K:\a

-f\BN

SF\1

3955

091\

_Her

efor

d_TX

_Re

plac

emen

t Dep

ot\0

4_Pr

oduc

tion\

01_C

AD\0

2_Sh

eets

\HER

ETX-

2021

-B-0

-A30

0.dw

gFi

le P

ath:

EAL

MJM

EBJ

MEP

70952

FACILITIES ENGINEERING

4515 KANSAS AVE.

KANSAS CITY, KS. 66106

5151 Mochel Drive, Suite 205

Downers Grove, IL 60515

Phone 630 499-4110

Fax 630 499-4119

tkda.com

DESIGN FIRM PROJ. MGR.

0 11/9/21 EBJ 30% ISSUE FOR BID

0 4' 8'

Scale: 3/16" = 1'-0"

ELECTRICAL, TELECOM, AND FURNITURE PLAN

1

8

9

HERETX-2021-B-0-A300.dwg

ELECTRICAL, TELECOM, AND FURNITURE PLAN

A300

8

LEGEND

DATA J-BOX W/ 1" CONDUIT

DATA J-BOX W/ 1" CONDUIT MOUNTED 6" ABOVE COUNTER

SINGLE / DEDICATED POWER OUTLET

DUPLEX POWER OUTLET

QUADPLEX POWER OUTLET

WATERPROOF GFI DUPLEX POWER OUTLET

DUPLEX RECEPTACLE MOUNTED 6" ABOVE COUNTER

DUPLEX GFI RECEPTACLE MOUNTED 6" ABOVE COUNTER

WALL MOUNTED EXTERIOR LED LIGHT ON PHOTOCELL

FLUSH MOUNTED FLOOR DATA/POWER OUTLETS

PROVIDE CONDUIT TO DATA J-BOX

INTERCOM, PROVIDE POWER AND DATA

24-VOLT ELECTRIC STRIKE AND CARD READER

WIRELESS REMOTE

CCTV SECURITY CAMERA, PROVIDE JUNCTION BOX

AND WIRING TO ALL LOCATIONS. AT EXTERIOR

LOCATIONS, PROVIDE RIGID METAL CONDUIT

EXTENDING BACK INTO BUILDING TERMINATING ABOVE

CEILING.

LED WALL OR PENDANT-MOUNTED LIGHT FIXTURE

MOUNTED 13'-0" A.F.F. MIN. CONTROLLED BY

OCCUPANCY SENSOR

THERMOSTAT

EXIT LIGHT

EMERGENCY LIGHT

DISCONNECT SWITCH

MOTOR

PROVIDE JUNCTION BOX AND WIRING TO ALL LOCATIONS

FOR INTERCOM AND 24-VOLT ELECTRIC STRIKE AND

CARD READER. AT EXTERIOR LOCATIONS, PROVIDE RIGID

METAL CONDUIT EXTENDING BACK INTO BUILDING

TERMINATING ABOVE CEILING.

IC

24V

C

WR

KEY NOTES

REFER TO SPECIFICATIONS

FOR ADDITIONAL INFORMATIO N

10

11

FURNACE 1: 103, 104, 105, 106

FURNACE 2: 101, 102, 107, 108, 109, 110

UNIT HEATERS: 114

PROVIDE WALL-MOUNTED THERMOSTAT CONTROL FOR

DUCTLESS MINI-SPLIT SYSTEM INSIDE TELECOM ROOM 112.

HVAC ZONES

J

EXISTING CONDUIT

CONDUIT CONCEALED OR UNDERGROUND

CONDUIT CONCEALED IN CEILING OR WALL

CONDUIT DOWN

CONDUIT UP

CONDUIT STUB

LP101

1,3

GROUND CONDUCTOR

HOME RUN

P

##

PNEUMATIC TUBING

3/4" C., TO CEILING

TELEPHONE OUTLET, (W-WALL) STUB

TELEPHONE/DATA OUTLET

CONDUIT RUN EXPOSED

b

2

A

RECESSED FLUORESCENT FIXTURE

SURFACE MOUNTED LIGHTING FIXTURE

b

3

DUPLEX NEMA 5-20R RECEPTACLE

SPECIAL PURPOSE OUTLET

JUNCTION BOX

DISCONNECT SWITCH

COMBINATION MAGNETIC STARTER

MAGNETIC STARTER

MANUAL STARTER

THERMOSTAT FOR HVAC EQUIPMENT

MC-MOMENTARY CONTACT, K-KEY, P-PILOT)

THREE WAY SWITCH (2-2 POLE, 4-4 WAY,

EXIT LIGHT (ARROWS AND FACES AS SHOWN)

SINGLE POLE SWITCH AND SWITCH LETTER

SINGLE RECEPTACLE

ELECTRICAL PLAN SYMBOLS

SURFACE MOUNTED/CHAIN HUNG FLUORESCENT FIXTURE

POLE MOUNTED SITE LIGHTING FIXTURE (PARKING LOT)

PANEL AND CIRCUIT DESIGNATION

PANEL LP101, CKT 1,3

TRANSFORMER

CIRCUIT BREAKER

CIRCUIT BREAKER WITH EXTERNAL DISCONNECT HANDLE

MOTOR OVERLOAD PROTECTOR

TRANSFER SWITCH-MANUAL OR AUTOMATIC AS INDICATED

GROUND CONNECTION

GENERATOR

PANEL AS INDICATED

FUSE

SUPERVISORY CONTROL PANEL

H-O-A SELECTOR SWITCH

DISCONNECT SWITCH

WALL MOUNTED LIGHTING FIXTURE

EXIT LIGHT WITH EMERGENCY LIGHTS

DOUBLE DUPLEX RECEPTACLE

MOTOR

CONTROL DEVICE

POWER HEAD FOR HEAT TRACE

END UNIT FOR HEAT TRACE

THERMOSTAT FOR HEAT TRACE

ALARM HORN

STROBE LIGHT

CONDUIT CONTINUATION

PHOTO CELL

PEC

GREEN RUN PILOT LIGHT

H-O-A SELECTOR SWITCH

ELAPSE TIME METER

DIAMOND WITH NUMBER INDICATES

CONDUIT NUMBER AS SCHEDULED IN

DEVICE, MOTOR & EQUIPMENT OR

SUPPLEMENTAL CONDUIT SCHEDULE.

HATCH MARKS INDICATE #12 AWG

CONDUCTORS UNLESS NOTED

OTHERWISE NO HATCH MARKS = 2 #12

FIXTURE TYPE

CIRCUIT NUMBER

SWITCH IDENTIFICATION

SCHEMATIC SYMBOLS

PUSHBUTTON

NORMALLY OPEN

MUSHROOM HEAD

PUSHBUTTON

R

COLOR OF LIGHT

LETTER INDICATES

ILLUMINATED

PUSHBUTTON

SELECTOR SWITCH

3 POSITION

H

O

XOO

A

LIMIT SWITCH

RELAY CONTACTOR OR

MOTOR STARTER COIL

RELAY CONTACT

NORMALLY OPEN

RELAY CONTACT

NORMALLY CLOSED

PRESSURE SWITCH

TEMPERATURE SWITCH

FLOW SWITCH

FLOAT SWITCH

PROXIMITY SWITCH

FOOT SWITCH

PULLCORD SWITCH

PHOTOEYE SWITCH

TIME DELAY RELAY

TERMINAL

SHIELD GROUND TERMINAL

ANALOG SWITCHABLE TERMINAL

WIRE CONNECTION

R

PILOT LIGHT

LETTER INDICATES COLOR

R

PRESS TO TEST

PILOT LIGHT

ALARM BELL

ALARM BUZZER

ALARM HORN

V

VOLT METER

A

AMP METER

BATTERY

CAPACITOR

RESISTOR

OHMS

EARTH GROUND

EQUIPMENT GROUND

SOLENOID

CABLE MARKER

SHLD

CIRCUIT BREAKER

FUSED SWITCH

SINGLE PHASE

FUSED DISCONNECT

DISCONNECT SWITCH

OVERLOAD

SINGLE PHASE

MOTOR

HP

THREE PHASE

MOTOR

HP

NORMALLY CLOSED

OPEN ON RISE

NORMALLY OPEN

CLOSE ON RISE

THESE CONFIGURATIONS TYPICAL

FOR ALL SWITCHES

??

12

DIGITAL OUTPUT POWER

WIRE NUMBER

SOURCE OR DESTINATION RUNG

DESCRIPTION

PBLT2174-1

EMERGENCY STOP

CS1001

2174

DESCRIPTION

ID TAG

XREF LOCATION

CR137-1

MAIN POWER ON

611

A1 A2

NO

NC

DESCRIPTION

ID TAG

XREF LOCATION

DESCRIPTIVE TEXT

PINS

H1 H2

TRANSFORMER

X2X1

NORMALLY OPEN

CLOSE ON FALL

NORMALLY CLOSED

OPEN ON FALL

THREE WIRE

PROXIMITY SWITCH

HIGH MAST DROP RING LIGHT TOWER

PAD/RACK MOUNT TRANSFORMER

PANELBOARD

JUNCTION BOX

CONTROL PANEL

LIGHTING CONTACTOR

UNDERGROUND CONDUIT

AERIAL

##CONSTRUCTION KEYED NOTE

CROSSARM MOUNTED LIGHTING FIXTURE

CONNEX STORAGE TRAILERCON

POLE TOP MOUNTED TRANSFORMERT

LPX

HANDHOLE

HH1000

ONE-LINE SYMBOLS

CAMCAMERA

ON POLE MT# = LIGHT POLE #

JB

CP

LC

LOAD BREAK CABINET

MEDIUM VOLTAGE SWITCHMVS

MT#

T

LBC

# - POLE NUMBER

A - POLE CLASS

B - POLE HEIGHT

DOWN GUY

#

A B

FUSED CUTOUT

LOAD BREAK ELBOW

TERMINATION

DEAD BREAK ELBOW

LIGHTNING ARRESTOR

M

METER

BOLLARD

WOOD POLE

X INDICATES CONTACT CLOSED

IN THE ASSOCIATED POSITION

S

P

S

P

E N

10

Bar i

s one

inch

on

orig

inal

dra

win

g. If

not

one

inch

on

this

draw

ing,

adj

ust s

cale

s acc

ordi

ngly

.

DATENO. BY DESCRIPTION OF REVISIONS

SERVICE REQUISTION NO.:

STATE

PROJ. TYPE

STATION

FILENAME:

PROJ. DESC.

CHKD.

DES.

DRWN.

DESIGN FIRM PROJ. NO.

SHEET:

DRAWING NUMBER

OF

APPROVED

DRAWING DESC.

TX

FACILITIES

HEREFORD

ERIC JOHNSON13955.114

CONCEPTUAL DESIGN

14

11/5

/202

1Da

te P

lott

ed:

K:\a

-f\BN

SF\1

3955

091\

_Her

efor

d_TX

_Re

plac

emen

t Dep

ot\0

4_Pr

oduc

tion\

01_C

AD\0

2_Sh

eets

\HER

ETX-

2021

-B-0

-E00

0.dw

gFi

le P

ath:

EAL

MJM

EBJ

MEP

70952

FACILITIES ENGINEERING

4515 KANSAS AVE.

KANSAS CITY, KS. 66106

5151 Mochel Drive, Suite 205

Downers Grove, IL 60515

Phone 630 499-4110

Fax 630 499-4119

tkda.com

DESIGN FIRM PROJ. MGR.

0 11/9/21 EBJ 30% ISSUE FOR BIDHERETX-2021-B-0-E000.dwg

ELECTRICAL SYMBOLS

E000

9

PROJECT GENERAL NOTES:

A. CONDUIT ROUTING SHOWN IS SCHEMATIC. VERIFY ROUTING OF

ALL, PROPOSED AND EXISTING, CONDUITS, FEEDERS AND

CABLES. NOT ALL EXISTING FEEDERS ARE INDICATED ON THESE

PLANS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR

REPLACING ALL ITEMS DAMAGED DURING ELECTRICAL

EXCAVATION. UTILITY LOCATES SHALL BE COMPLETED PRIOR TO

ANY SAW CUTTING, EXCAVATION, PLOWING, OR BORING.

B. COORDINATE WORK WITH OWNER'S SYSTEMS.

C. ROUTE ALL UNDERGROUND CABLING IN CONDUIT.

D. MINIMUM BURIED DEPTH OF 600V OR LESS CONDUIT IS 2'-0"

BELOW FINISHED SURFACE. TRENCH BACK-FILL SHALL BE IN 6"

COMPACTED LIFTS. CONDUIT 600V OR GREATER SHALL HAVE A

BURIED DEPTH OF 30". CONDUIT UNDER TRACK SHALL HAVE A

MAINTAINED BURIAL DEPTH OF 6' BELOW TOP OF RAIL.

E. RETURN SITE / SURFACE CONDITIONS TO PRE-CONSTRUCTION

STATE. REMOVE ALL SURFACE PILES AND DEBRIS.

F. DURING CONSTRUCTION, PROVIDE DUST CONTROL FOR VEHICLE

AND EQUIPMENT USAGE.

G. UNDERGROUND CONDUIT SHALL BE SCHEDULE 80 PVC OR

EQUIVALENT SCHEDULE 80 WALL THICKNESS HDPE. SEE

SPECIFIC CONDUIT SCHEDULES FOR CONDUIT SIZES.

UNDERGROUND 90-DEGREE ELBOWS SHALL BE LONG SWEEP,

PVC COATED RMC. UNLESS OTHERWISE NOTED, INTERIOR

CONDUIT SHALL BE RMC.

H. UNLESS OTHERWISE NOTED, EXPOSED CONDUIT STUB

TRANSITIONS TO ABOVE GRADE SHALL BE THREADED CONDUIT

(RMC) AND SHALL HAVE FIELD APPLIED ANTI-CORRSION

PROTECTION.

I. WIRING SHALL BE PROVIDED TO EQUIPMENT AND DEVICES AS

INDICATED. AMPACITY, DERATING (VOLTAGE DROP) AND CONDUIT

SHALL BE AS REQUIRED BY THE NEC AND ENERGY CODE AS

INDICATED.

J. RECEPTACLE DEVICES ON SITE PLAN INDICATED WP SHALL BE

GFCI AND LISTED WEATHER-RESISTANT, SHALL HAVE "EXTRA

DUTY" TYPE WEATHER-PROOF COVERS AND WEATHER-PROOF

ENCLOSURES.

K. RACEWAYS SHALL CONTAIN A GROUNDING CONDUCTOR. SIZE

GROUNDING CONDUCTOR PER NEC.

L. ALL CIRCUIT CONDUCTOR SIZING SHALL BE INCREASED WHERE

REQUIRED FOR VOLTAGE DROP AND INCREASED TO ACCOUNT

FOR DERATING DUE TO AMBIENT TEMPERATURE. THE VOLTAGE

DROP CALCULATION SHALL BE BASED ON 80% OF THE AMPACITY

OF THE WIRE AND NOT THE PROJECTED LOAD, UNLESS

OTHERWISE APPROVED IN WRITING BY THE ENGINEER. ALL

BRANCH CIRCUIT AND FEEDER WIRING SHALL LIMIT THE VOLTAGE

DROP TO 3% FOR EITHER SEGMENT AND 5% OVERALL.

M. UNLESS OTHERWISE NOTED, CIRCUITS SUPPLYING LINE TO

NEUTRAL LOADS SHALL HAVE DEDICATED NEUTRALS, i.e. ONE

NEUTRAL PER PHASE. NEUTRAL CONDUCTORS SHALL HAVE

TRACER STRIPE ALONG ENTIRE LENGTH INDICATING ASSOCIATED

PHASE.

N. EXTERIOR, INCLUDING UNDERGROUND, CONDUCTORS SHALL BE

XHHW, UNLESS OTHERWISE NOTED.

O. CRITICAL DEVICES / EQUIPMENT, INCLUDING TELEPHONE,

COMPUTER, AND SECURITY, AFFECT ASSOCIATED SYSTEMS RAIL

YARD WIDE. THESE SYSTEMS MUST REMAIN OPERATIONAL

DURING THE CONSTRUCTION. INDIVIDUAL DEVICES MAY BE

DISCONNECTED AND/OR RECONNECTED DURING

CONSTRUCTION. COORDINATE OUTAGES AND DISRUPTIONS

WITH OWNER. PROVIDE TEMPORARY PANEL(S) AND/OR

CIRCUIT(S) AS NECESSARY TO MAINTAIN CONTINUITY. PROTECT

FROM PHYSICAL AND DUST DAMAGE.

P. COORDINATE ALL CUTTING AND PATCHING LOCATIONS WITH

OWNER. PATCHING SHALL MATCH EXISTING FINISH.

Q. WHERE USED IN THE DRAWINGS, THE TERM "DEMOLISHED"

INCLUDES ALL LABOR AND EQUIPMENT NEEDED TO COMPLETE

REMOVAL. UNLESS OTHERWISE NOTED, ANY REMOVAL OF

DEVICES AND/OR EQUIPMENT INCLUDES REMOVAL OF RACEWAY

AND ASSOCIATED CONDUCTORS BACK TO LAST ACTIVE SOURCE.

PROVIDE WP KO SEALS FOR ALL UNUSED CONDUIT OPENINGS IN

EQUIPMENT TO REMAIN. REMOVE ALL DEMOLITION FROM SITE.

R. SITE BACKGROUND IS CREATED FROM AERIAL PHOTO. FIELD

VERIFY SCALED DIMENSIONS.

S. ALL JUNCTION/PULL BOXES SHALL BE NEMA 4X, HINGED,

STAINLESS STEEL UNLESS OTHERWISE NOTED.

T. ALL 600V RATED CONDUCTORS SHALL BE COPPER UNLESS

OTHERWISE NOTED.

U. ALL CONDUIT PENETRATIONS TO EQUIPMENT LOCATED OUTSIDE

BUILDINGS SHALL BE MADE WITH "MYERS" TYPE WEATHERPROOF

HUBS. ALL PENETRATIONS SHALL BE FROM THE BOTTOM OR

SIDE NEAR BOTTOM OF PANEL ONLY. IN THE CASE WHERE TOP

PENETRATIONS ARE THE ONLY OPTION CONTACT THE ENGINEER

FOR APPROVAL.

V. ALL TOP SIDE CONDUIT PENETRATIONS TO EQUIPMENT LOCATED

INSIDE BUILDINGS SHALL BE MADE WITH "MYERS" TYPE

WEATHERPROOF HUBS.

W. ALL UNISTRUT CHANNEL SHALL BE GALVANIZED. ALL

GALVANIZED CHANNEL SHALL BE COATED WITH TWO COATS OF

COLD GALVANIZE PAINT WHERE CUTS AND/OR WELDS OCCUR.

X. PROVIDE PROPER COATING TO ALL EXPOSED CONDUIT THREADS

AND FIELD CUT ENDS OF CONDUIT. COATING SHALL BE

APPROVED ELECTRICALLY CONDUCTIVE CORROSION-RESISTANT

COMPOUND SUITABLE FOR THE APPLICATION.

Y. ALL ELECTRICAL WORK SHALL COMPLY WITH THE NEC AND ALL

LOCAL CODES.

Z. CONTRACTOR SHALL SIZE AND PROVIDE PULL BOXES, JUNCTION

BOXES, VAULTS, AND HAND HOLES AS REQUIRED BY THE NFPA

NATIONAL ELECTRICAL CODE (NEC) AND THE WIRE

MANUFACTURER'S SPECIFICATIONS, UNLESS OTHERWISE NOTED.

AA. CONTRACTOR SHALL PROVIDE THE ENGINEER WITH A COMPLETE

SET OF REDLINE AS-BUILT DRAWINGS.

AB. PROVIDE ALL RACEWAYS, CONDUCTORS, CABLES,

TERMINATIONS, AND TESTING REQUIRED TO COMPLETE

PROJECT.

AC. PROVIDE ALL GROUNDING REQUIRED PER THE DRAWINGS,

SPECIFICATIONS, AND NEC.

AD. PROVIDE LABELING FOR ALL ELECTRICAL EQUIPMENT INCLUDING

EXISTING EQUIPMENT INVOLVED IN PROJECT PER DRAWINGS

AND SPECIFICATIONS.

AE. WHERE USED IN THE DRAWINGS, THE TERM "PROVIDE" INCLUDES

ALL EQUIPMENT, MATERIAL, AND LABOR REQUIRED TO COMPLETE

INSTALLATION.

AF. COORDINATE ALL SHUTDOWNS, CUTOVERS, AND THEIR

DURATIONS WITH OWNER AND UTILITY COMPANY. PROVIDE

TEMPORARY POWER AS REQUIRED DURING OUTAGES.

AG. COORDINATE AND ASSIST WITH STARTUP AND TESTING OF ALL

EQUIPMENT WITH ASSOCIATED MANUFACTURERS. PROVIDE

TESTING DOCUMENTATION.

AH. THE PROJECT PLANS AND SPECIFICATIONS ARE NOT TO BE USED

SEPARATELY.

ABBREVIATIONS

℄ CENTER LINE

3P THREE POLE

AC AIR CONDITIONER

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AFS AIR FLOW SWITCH

AH ALARM HORN

AHU AIR HANDLING UNIT

AI ANALOG INPUT

AL ALARM

AM AMMETER

AO ANALOG OUTPUT

APPROX APPROXIMATE

AQ AQUA STAT

ATS AUTO TRANSFER SWITCH

AUTO AUTOMATIC

AUX AUXILIARY SWITCH

BCP BURNER CONTROL PANEL

BFG BELOW FINISHED GRADE

BLDG BUILDING

BS BOLT SWITCH

BSMT BASEMENT

C CONTACTOR

CAB CABINET

CB CIRCUIT BREAKER

CBL CABLE

CKT CIRCUIT

CLG CEILING

CLS CAM LIMIT SWITCH

CONC CONCRETE

CP CONTROL PANEL

CPF CONTROL PANEL FAN KIT

CPT CONTROL POWER TRANSFORMER

CR CONTROL RELAY

CS CONTROL STATION

CT CURRENT TRANSFORMER

CTB CUSTOMER TERMINAL BOARD

CTP CURRENT TRANSFORMER PANEL

DB DISTRIBUTION BLOCK

DCON DATA CONCENTRATOR PANEL

DCS DISTRIBUTED CONTROL SYSTEM

DCU DISTRIBUTED CONTROL UNIT

DI DIGITAL INPUT

DIM DIMENSION

DIV DIVISION

DM DISPLAY METER

DN DOWN

DNP DNP COMMUNICATIONS MODULE

DO DIGITAL OUTPUT

DP DISTRIBUTION PANEL - ABOVE 240V

DS DISCONNECT SWITCH

DSW DOOR SWITCH

DT DOUBLE THROW

DV DEVICE

DWG DRAWING

E-STOP EMERGENCY STOP

EA EACH

ELECT ELECTRICAL

ELEV ELEVATION

EPB E-STOP PUSHBUTTON

EPC EMERGENCY PULL CORD

EQUIP EQUIPMENT

ES EMERGENCY STOP

ESW ETHERNET SWITCH

ETM ELAPSED TIME METER

ETH ETHERNET PLC MODULE

F FAN

FFN FUEL FLOW NETWORK

FI FAULT INTERRUPTER

FL FLOOR

FM FLOW METER

FOC FIBER OPTIC CONVERTER

FPB FLASH PROTECTION BOUNDARY

FS FLOW SWITCH

FT FEET

FT FLOW TRANSMITTER

FTP FIBER TERMINATION PANEL

FU FUSE

FVMS MAGNETIC FULL VOLTAGE MULTI-SPEED MOTOR STARTER

FVNR MAGNETIC FULL VOLTAGE NON-REVERSING MOTOR STARTER

FVR MAGNETIC FULL VOLTAGE REVERSING MOTOR STARTER

G GROUNDED

GEN GENERATOR

GFEPGROUND FAULT EQUIPMENT PROTECTION

GFI GROUND FAULT INTERRUPTER

GND GROUND

HC HEATER CONTACTOR

HCV HYDRAULIC CONTROL VALVE

HE HEAT EXCHANGER

HH HAND HOLE

HMI HUMAN MACHINE INTERFACE

HOA HAND-OFF-AUTO

HP HORSE POWER

HT HEAT TRACE

HTMP HEAT TRACE MONITORING PANEL

HTR HEATER

HZ HERTZ

I/P CURRENT TO PRESSURE

ID INSIDE DIAMETER

ILPB ILLUMINATED PUSHBUTTON

IN INCHES

INSTR INSTRUMENT

ISB INTRINSIC SAFETY BARRIER

ISO MODBUS TO FIBER OPTIC CONVERTER

JB JUNCTION BOX OR PULL BOX

kcMIL THOUSANDS OF CIRCULAR MILS

KS KEY SWITCH

KVA KILOVOLT AMPERES

KVAR KILOVOLT AMPERES REACTIVE

KW KILOWATT

KWH KILOWATT HOUR

LA LIGHTNING ARRESTOR

LBC LOAD BREAK CABINET

LCP LIGHTING CONTROL PANEL

LCV LEVEL CONTROL VALVE

LF FLUORESCENT LIGHT

LFTP LOCAL FIBER TERMINATION PANEL

LI LOAD INTERRUPTER

LP LOW VOLTAGE PANEL - 240V AND BELOW

LR LINE OR LOAD REACTOR

LSW LIMIT SWITCH

LS LEVEL SWITCH

LT LEVEL TRANSMITTER

M MOTOR

MA MOTOR ALARM CONTACT

MAX MAXIMUM

MB MAIN BREAKER

MCC MOTOR CONTROL CENTER

MCP MOTOR CIRCUIT PROTECTOR OR MOTOR CONTROL PANEL

MECH MECHANICAL

MH MANHOLE

MIN MINIMUM

MISC MISCELLANEOUS

MOD MODBUS COMMUNICATION MODULE

MPF MOTOR PROTECTOR FILTER

MPZ MINI POWER-ZONE

MR MOTOR RUNNING INDICATION

MS MOTOR STARTER

MT EMPTY

MTS MANUAL TRANSFER SWITCH

MV MOTORIZED VALVE

NC NORMALLY CLOSED

NCS NON-CONTACT SWITCH

NEUT NEUTRAL

NIC NOT IN CONTRACT

NO NORMALLY OPEN

NTS NOT TO SCALE

OC ON CENTER

OD OUTSIDE DIAMETER

OI OPTICAL ISOLATOR

OL OVERLOAD RELAY

OPG OPENING

OWS OIL WATER SEPERATOR

P PUMP

P/I PRESSURE TO CURRENT

PB PUSH BUTTON

PBS PUSH BUTTON STATION

PCON PROCESS CONTROL PANEL

PEC PHOTO ELECTRIC CELL

PER PHOTO ELECTRIC RELAY

PH PHASE

PHS PHASE SENSOR

PI PULSE INPUT

PL PILOT LIGHT

PLC PROGRAMMABLE LOGIC CONTROLLER

PM POWER METER

PO PULSE OUTPUT

POT POTENTIOMETER

PPEPERSONAL PROTECTIVE EQUIPMENT

PRI PRIMARY

PS PRESSURE SWITCH

PT PRESSURE TRANSMITTER

PVC POLYVINYL CONDUIT

PWS POWER SUPPLY

REC RECEPTACLE

REQD REQUIRED

RMC RIGID METAL CONDUIT

RP RADIO PANEL

RST RESET

RT RAIN TIGHT

RTD RESISTANCE TEMPERATURE DETECTOR

RVNR MAGNETIC REDUCED VOLTAGE NON-REVERSING MOTOR STARTER

SCADASUPERVISORY CONTROL AND DATA ACQUISITION

SCC SHORT CIRCUIT CURRENT

SCCR SHORT CIRCUIT CURRENT RATING

SE SENSOR

SEC SECONDARY

SFS SOFT START MOTOR STARTER

SH SHEET

SIG

SIGNAL (POLES)

SL STROBE LIGHT

SP SINGLE POLE

SPD SURGE PROTECTION DEVICE

SR SAFETY RELAY

SS SELECTOR SWITCH

ST SINGLE THROW

SU SURGE SUPPRESSOR

SV SOLENOID VALVE

SW SWITCH

SWGR SWITCHGEAR

T TRANSFORMER

TB TERMINAL BOARD

TC THERMOCOUPLE

TD TIME DELAY

TEL TELEPHONE TERMINAL

TELE

TELEPHONE (POLES)

TMR TIMER RELAY

TP NETWORK TAP

TS TEMPERATURE SWITCH

TT TEMPERATURE TRANSMITTER

TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR

TYP TYPICAL

UAL UNIVERSAL ALARM LOGIC

UH UNIT HEATER

UPS UNINTERRUPTIBLE POWER SUPPLY

V VOLTS

VFDVARIABLE FREQUENCY DRIVE

VM VOLT METER

VT VAPOR TIGHT

W WATTS

WD WIRE DUCT

WHM WATT HOUR METER

WP WEATHER PROOF

WR WIRELESS RADIO

WT WATER TIGHT

XFMR TRANSFORMER

XP EXPLOSION PROOF

ZS LIMIT SWITCH

10

Bar i

s one

inch

on

orig

inal

dra

win

g. If

not

one

inch

on

this

draw

ing,

adj

ust s

cale

s acc

ordi

ngly

.

DATENO. BY DESCRIPTION OF REVISIONS

SERVICE REQUISTION NO.:

STATE

PROJ. TYPE

STATION

FILENAME:

PROJ. DESC.

CHKD.

DES.

DRWN.

DESIGN FIRM PROJ. NO.

SHEET:

DRAWING NUMBER

OF

APPROVED

DRAWING DESC.

TX

FACILITIES

HEREFORD

ERIC JOHNSON13955.114

CONCEPTUAL DESIGN

14

11/5

/202

1Da

te P

lott

ed:

K:\a

-f\BN

SF\1

3955

091\

_Her

efor

d_TX

_Re

plac

emen

t Dep

ot\0

4_Pr

oduc

tion\

01_C

AD\0

2_Sh

eets

\HER

ETX-

2021

-B-0

-E00

1.dw

gFi

le P

ath:

EAL

MJM

EBJ

MEP

70952

FACILITIES ENGINEERING

4515 KANSAS AVE.

KANSAS CITY, KS. 66106

5151 Mochel Drive, Suite 205

Downers Grove, IL 60515

Phone 630 499-4110

Fax 630 499-4119

tkda.com

DESIGN FIRM PROJ. MGR.

0 11/9/21 EBJ 30% ISSUE FOR BIDHERETX-2021-B-0-E001.dwg

ELECTRICAL ABBREVIATIONS

E001

10

NOTES:

1. LABEL SHALL BE RED PHENOLIC WITH 1/2" HEIGHT

MINIMUM WHITE ENGRAVED LETTERING.

2. EQUIPMENT CONTAINING MULTIPLE POWER

SOURCES SHALL INCLUDE LABELS DETAILING EACH

POWER SOURCE.

3. SEE ELECTRICAL PLAN SET FOR REQUIRED X, XX,

XXX, OR XXXX DATA. FIELD VERIFY IF PLAN SET IS

NOT AVAILABLE.

4. USE NEC 110 TO DETERMINE THE PROPER

CLEARANCE. USE PRE-PRINTED BRADY LABELS.

5. USE BRADY LABEL MODEL NUMBER 101519 OR AN

APPROVED EQUAL.

6. DETAIL D IS THE EQUIPMENT ID LABEL. SEE

ELECTRICAL PLAN SET FOR REQUIRED DATA. FIELD

VERIFY IF PLAN SET IS NOT AVAILABLE.

7. SUBMIT, TO ENGINEER FOR APPROVAL, A SCHEDULE

OF ALL NAMEPLATES PRIOR TO MANUFACTURE.

8. SERVICE ENTRANCE EQUIPMENT SHALL BE LABELED

WITH SHORT CIRCUIT CURRENT RATING (SCCR) AND

AVAILABLE SHORT CIRCUIT CURRENT.

9. MOTOR CONTROL CENTERS (MCC) AND AUTOMATIC

TRANSFER SWITCHES SHALL BE LABELED WITH

SHORT CIRCUIT CURRENT RATING (SCCR).

NO SCALE

1

E002

TRANSFORMER LABELING TYPICAL DETAILS

NO SCALE

2

E002

PANELBOARD LABELING TYPICAL DETAILS

NO SCALE

3

E002

MOTOR CONTROL CENTER LABELING TYPICAL DETAILS

NO SCALE

4

E002

DISCONNECT LABELING TYPICAL DETAILS

1

2

3

4

5

6

FRONT

TXXXX

XXXXKVA, X PHASE

PRIMARY SUPPLIED VIA A DELTA OR WYE

GROUNDED OR UNGROUNDED SYSTEM

FROM XXX LOCATED ON/OR IN XXX

PRI WINDING CONFIGURATIONS IS DELTA OR WYE.

XX.XXk VOLT PHASE TO PHASE OR NEUTRAL

SEC WINDING CONFIGURATION IS DELTA OR WYE,

GROUNDED OR UNGROUNDED

XXX/XXX VOLT, X-PHASE, X-WIRE

SECONDARY FEEDS XXX LOCATED AT THE

XXXXXXXX AREA

AREA IN FRONT OF THIS

ELECTRICAL EQUIPMENT MUST BE

KEPT CLEAR FOR XX INCHES.

OSHA-NEC REGULATIONS

CAUTION

DETAIL B

WARNING

DETAIL C

ARC FLASH & SHOCK HAZARD

APPROPRIATE PERSONAL PROTECTION

EQUIPMENT REQUIRED

DETAIL A

A

B

C

1

2

3

4

5

NOTE:

DIRECTORY

MUST

BE TYPED

AND

CURRENT

E

B

A

DETAIL E

FRONT

INSIDE DOOR

PANELBOARD EXTERIORPANELBOARD INTERIOR

C

MAIN OR SUB PANEL

LP/DPXXXX

XXX/XXX VOLT, X PHASE, X-WIRE

XXXX AMPERE

PANEL IS FED FROM XXXX

LOCATED ON/OR IN XXXX

AREA IN FRONT OF THIS

ELECTRICAL EQUIPMENT MUST BE

KEPT CLEAR FOR XX INCHES.

OSHA-NEC REGULATIONS

CAUTION

DETAIL B

WARNING

DETAIL C

ARC FLASH & SHOCK HAZARD

APPROPRIATE PERSONAL PROTECTION

EQUIPMENT REQUIRED

DETAIL A

1

2

3

4

5

MAIN FEEDER SECTION

EQUIPMENT ID MCCXXXX

XXX/XXX VOLT, X PHASE, X-WIRE

XXXX AMPERE

MCC IS FED FROM XXXX

LOCATED ON/OR IN XXXX

AREA IN FRONT OF THIS

ELECTRICAL EQUIPMENT MUST BE

KEPT CLEAR FOR XX INCHES.

OSHA-NEC REGULATIONS

CAUTION

DETAIL B

WARNING

DETAIL C

ARC FLASH & SHOCK HAZARD

APPROPRIATE PERSONAL PROTECTION

EQUIPMENT REQUIRED

E

INSIDE DOOR

SECTION 1 SECTION 2 SECTION 3

FRONT

A

CONTROL CIRCUIT IS FED FROM

XXXX LOCATED IN XXXXX

DETAIL E

B

C

DETAIL A

XXXX

DETAIL D

D

D

D

D

D

D

D D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

1

2

3

4

5

1

3

3

6

1

A

FRONT

MAIN SERVICE OR EQUIPMENT OR

TRANSFORMER DISCONNECT

DSXXXX

XXX/XXX VOLT, X PHASE, X-WIRE

XXXX AMPERE

DISCONNECT IS FED FROM XXXX

LOCATED ON/OR IN XXXX.

AREA IN FRONT OF THIS

ELECTRICAL EQUIPMENT MUST BE

KEPT CLEAR FOR XX INCHES.

OSHA-NEC REGULATIONS

CAUTION

DETAIL B

DETAIL A

WARNING

DETAIL C

ARC FLASH & SHOCK HAZARD

APPROPRIATE PERSONAL PROTECTION

EQUIPMENT REQUIRED

B

C

1

2

3

4

5

10

Bar i

s one

inch

on

orig

inal

dra

win

g. If

not

one

inch

on

this

draw

ing,

adj

ust s

cale

s acc

ordi

ngly

.

DATENO. BY DESCRIPTION OF REVISIONS

SERVICE REQUISTION NO.:

STATE

PROJ. TYPE

STATION

FILENAME:

PROJ. DESC.

CHKD.

DES.

DRWN.

DESIGN FIRM PROJ. NO.

SHEET:

DRAWING NUMBER

OF

APPROVED

DRAWING DESC.

TX

FACILITIES

HEREFORD

ERIC JOHNSON13955.114

CONCEPTUAL DESIGN

14

11/5

/202

1Da

te P

lott

ed:

K:\a

-f\BN

SF\1

3955

091\

_Her

efor

d_TX

_Re

plac

emen

t Dep

ot\0

4_Pr

oduc

tion\

01_C

AD\0

2_Sh

eets

\HER

ETX-

2021

-B-0

-E00

2.dw

gFi

le P

ath:

EAL

MJM

EBJ

MEP

70952

FACILITIES ENGINEERING

4515 KANSAS AVE.

KANSAS CITY, KS. 66106

5151 Mochel Drive, Suite 205

Downers Grove, IL 60515

Phone 630 499-4110

Fax 630 499-4119

tkda.com

DESIGN FIRM PROJ. MGR.

0 11/9/21 EBJ 30% ISSUE FOR BIDHERETX-2021-B-0-E002.dwg

LABELING DETAILS

E002

11

NOTES:

1. LABEL SHALL BE RED PHENOLIC WITH 1/2" HEIGHT

MINIMUM WHITE ENGRAVED LETTERING.

2. EQUIPMENT CONTAINING MULTIPLE POWER

SOURCES SHALL INCLUDE LABELS DETAILING EACH

POWER SOURCE.

3. SEE ELECTRICAL PLAN SET FOR REQUIRED X, XX,

XXX, OR XXXX DATA. FIELD VERIFY IF PLAN SET IS

NOT AVAILABLE.

4. USE NEC 110 TO DETERMINE THE PROPER

CLEARANCE. USE PRE-PRINTED BRADY LABELS.

5. USE BRADY LABEL MODEL NUMBER 101519 OR AN

APPROVED EQUAL.

6. PROVIDE 2.25" WIDE YELLOW VINYL WITH BLACK

LETTERING SELF STICKING PRINTED LABELS.

7. DETAIL D IS THE EQUIPMENT ID LABEL. SEE

ELECTRICAL PLAN SET FOR REQUIRED DATA. FIELD

VERIFY IF PLAN SET IS NOT AVAILABLE.

8. SUBMIT, TO ENGINEER FOR APPROVAL, A SCHEDULE

OF ALL NAMEPLATES PRIOR TO MANUFACTURE.

9. SERVICE ENTRANCE EQUIPMENT SHALL BE LABELED

WITH SHORT CIRCUIT CURRENT RATING (SCCR) AND

AVAILABLE SHORT CIRCUIT CURRENT.

NO SCALE

2

E003

INDOOR MEDIUM VOLTAGE SWITCH GEAR > 600V LABELING TYPICAL DETAILS

NO SCALE

3

E003

OUTDOOR MEDIUM VOLTAGE SWITCH GEAR > 600V LABELING TYPICAL DETAILS

1

2

3

4

5

6

7

MAIN FEEDER SECTION

EQUIPMENT ID XXXX

XXX/XXX VOLT, X PHASE, X-WIRE

XXXX AMPERE

SWITCH GEAR IS FED FROM XXXX

LOCATED ON/OR IN XXXX

AREA IN FRONT OF THIS

ELECTRICAL EQUIPMENT MUST BE

KEPT CLEAR FOR XX INCHES.

OSHA-NEC REGULATIONS

CAUTION

DETAIL B

WARNING

DETAIL C

ARC FLASH & SHOCK HAZARD

APPROPRIATE PERSONAL PROTECTION

EQUIPMENT REQUIRED

SECTION 1 SECTION 2 SECTION 3

FRONT

A

B

C

DETAIL A

XXXX

DETAIL D

DD

1

2

3

4

5

1

3

7

BACK

B

CD

FRONT

A

C D

SIDE

E

C

D

F

INTERIOR TANK (TOP)

F F F

WAY X

EQUIPMENT ID XXXX

XXXX AMPERE

DETAIL F

F F F F

6

OPERATION SECTION

EQUIPMENT ID XXXX

XXX/XXX VOLT, X PHASE, X-WIRE

XXXX AMPERE

SWITCH GEAR IS FED FROM XXXX

LOCATED ON/OR IN XXXX

AREA IN FRONT OF THIS

ELECTRICAL EQUIPMENT MUST BE

KEPT CLEAR FOR XX INCHES.

OSHA-NEC REGULATIONS

CAUTION

DETAIL C

WARNING

DETAIL D

ARC FLASH & SHOCK HAZARD

APPROPRIATE PERSONAL PROTECTION

EQUIPMENT REQUIRED

DETAIL A

1

2

3

4

5

TERMINATION SECTION

EQUIPMENT ID XXXX

XXX/XXX VOLT, X PHASE, X-WIRE

XXXX AMPERE

SWITCH GEAR IS FED FROM XXXX

LOCATED ON/OR IN XXXX

DETAIL B

1

2

3

CONTROL PANEL

CPXXXX

XXX/XXX VOLT, X PHASE, X-WIRE

XXXX AMPERE

PANEL IS FED FROM XXXX

LOCATED ON/OR IN XXXX.

DETAIL E

1

2

3

FRONT

AREA IN FRONT OF THIS

ELECTRICAL EQUIPMENT MUST BE

KEPT CLEAR FOR XX INCHES.

OSHA-NEC REGULATIONS

CAUTION

DETAIL B

WARNING

DETAIL C

ARC FLASH & SHOCK HAZARD

APPROPRIATE PERSONAL PROTECTION

EQUIPMENT REQUIRED

DETAIL A

A

B

C

1

2

3

4

5

NOTE:

DIRECTORY

MUST

BE TYPED

AND

CURRENT

E

DETAIL E

INSIDE DOOR

PANELBOARD INTERIOR

SUB PANEL

LPXXXX

XXX/XXX VOLT, X PHASE, X-WIRE

XXXX AMPERE

DETAIL D

1

2

3

D

TXXXX

XXXXKVA, X PHASE

PRIMARY SUPPLIED VIA A DELTA OR WYE

GROUNDED OR UNGROUNDED SYSTEM

FROM XXX LOCATED ON/OR IN XXX

PRI WINDING CONFIGURATION IS DELTA OR WYE.

XX.XXk VOLT PHASE TO PHASE OR NEUTRAL

SEC WINDING CONFIGURATION IS DELTA OR WYE,

GROUNDED OR UNGROUNDED

XXX/XXX VOLT, X-PHASE, X-WIRE

NO SCALE

1

E003

MINI POWER-ZONE LABELING DETAILS

10

Bar i

s one

inch

on

orig

inal

dra

win

g. If

not

one

inch

on

this

draw

ing,

adj

ust s

cale

s acc

ordi

ngly

.

DATENO. BY DESCRIPTION OF REVISIONS

SERVICE REQUISTION NO.:

STATE

PROJ. TYPE

STATION

FILENAME:

PROJ. DESC.

CHKD.

DES.

DRWN.

DESIGN FIRM PROJ. NO.

SHEET:

DRAWING NUMBER

OF

APPROVED

DRAWING DESC.

TX

FACILITIES

HEREFORD

ERIC JOHNSON13955.114

CONCEPTUAL DESIGN

14

11/5

/202

1Da

te P

lott

ed:

K:\a

-f\BN

SF\1

3955

091\

_Her

efor

d_TX

_Re

plac

emen

t Dep

ot\0

4_Pr

oduc

tion\

01_C

AD\0

2_Sh

eets

\HER

ETX-

2021

-B-0

-E00

3.dw

gFi

le P

ath:

EAL

MJM

EBJ

MEP

70952

FACILITIES ENGINEERING

4515 KANSAS AVE.

KANSAS CITY, KS. 66106

5151 Mochel Drive, Suite 205

Downers Grove, IL 60515

Phone 630 499-4110

Fax 630 499-4119

tkda.com

DESIGN FIRM PROJ. MGR.

0 11/9/21 EBJ 30% ISSUE FOR BIDHERETX-2021-B-0-E003.dwg

LABELING DETAILS

E003

12

NOTES:

1. LABEL SHALL BE RED PHENOLIC WITH 1/2" HEIGHT MINIMUM

WHITE ENGRAVED LETTERING.

2. EQUIPMENT CONTAINING MULTIPLE POWER SOURCES SHALL

INCLUDE LABELS DETAILING EACH POWER SOURCE.

3. SEE ELECTRICAL PLAN SET FOR REQUIRED X, XX, XXX, OR

XXXX DATA. FIELD VERIFY IF PLAN SET IS NOT AVAILABLE.

4. USE NEC 110 TO DETERMINE THE PROPER CLEARANCE. USE

PRE-PRINTED BRADY LABELS.

5. USE BRADY LABEL MODEL NUMBER 101519 OR AN APPROVED

EQUAL.

6. LABEL SHALL BE 3"X1" DOUBLE SIDED REVERSE ENGRAVED

ACRYLIC, RED WITH WHITE LETTERS (14PT ARIAL). SEE

CONTROL WIRING SCHEMATIC FOR DEVICE NUMBERS.

7. SUBMIT, TO ENGINEER FOR APPROVAL, A SCHEDULE OF ALL

NAMEPLATES PRIOR TO MANUFACTURE.

8. INDUSTRIAL CONTROL PANELS SHALL BE LABELED WITH

SHORT CIRCUIT CURRENT RATING (SCCR) AND AVAILABLE

SHORT CIRCUIT CURRENT.

6

DEVICE NUMBER

VOLTAGE

DEVICE DESCRIPTION

FRONT

1" BLACK CHARACTERS ON YELLOW BACKGROUND;

ELECTROMARK ET1041-KY-1S SERIES OR EQUAL.

ATTACH CABLE MARKER HOLDER TO CABLE WITH WEATHER

RESISTANT CABLE TIES

(A) TO XXXX

NO SCALE

1

E004

CONTROL PANEL LABELING TYPICAL DETAILS

NO SCALE

2

E004

JUNCTION BOX LABELING TYPICAL DETAILS

NO SCALE

3

E004

CABLE LABEL TYPICAL DETAIL

NO SCALE

4

E004

PULL BOX LABELING TYPICAL DETAILS

NO SCALE

5

E004

GENERAL LABELING TYPICAL DETAILS

NO SCALE

6

E004

GENERAL CONTROL DEVICE LABEL TYPICAL DETAIL

1

2

3

4

5

6

B

A

FRONT

CONTROL PANEL

CPXXXX

XXX/XXX VOLT, X PHASE, X-WIRE

XXXX AMPERE

PANEL IS FED FROM XXXX

LOCATED ON/OR IN XXXX.

AREA IN FRONT OF THIS

ELECTRICAL EQUIPMENT MUST BE

KEPT CLEAR FOR XX INCHES.

OSHA-NEC REGULATIONS

CAUTION

DETAIL B

WARNING

DETAIL C

ARC FLASH & SHOCK HAZARD

APPROPRIATE PERSONAL PROTECTION

EQUIPMENT REQUIRED

DETAIL A

1

2

3

4

5

C

JUNCTION BOX

JBXXXX

XXX/XXX VOLT, X PHASE, X-WIRE

XXXX AMPERE

CIRCUIT IS FED FROM XXXX

LOCATED ON/OR IN XXXX.

DETAIL A

FRONT

WARNING

DETAIL B

ARC FLASH & SHOCK HAZARD

APPROPRIATE PERSONAL PROTECTION

EQUIPMENT REQUIRED

A

B

1

2

3

5

PULL BOX

JBXXXX

XXX/XXX VOLT, X PHASE, X-WIRE

XXXX AMPERE

CIRCUIT IS FED FROM XXXX

LOCATED ON/OR IN XXXX

DETAIL A

FRONT

A

1

2

3

WARNING

THIS CABINET IS SUPPLIED WITH

MULTIPLE POWER SOURCES

BE SURE ALL ARE DISCONNECTED

BEFORE SERVICING

DETAIL A

1

2

3

10

Bar i

s one

inch

on

orig

inal

dra

win

g. If

not

one

inch

on

this

draw

ing,

adj

ust s

cale

s acc

ordi

ngly

.

DATENO. BY DESCRIPTION OF REVISIONS

SERVICE REQUISTION NO.:

STATE

PROJ. TYPE

STATION

FILENAME:

PROJ. DESC.

CHKD.

DES.

DRWN.

DESIGN FIRM PROJ. NO.

SHEET:

DRAWING NUMBER

OF

APPROVED

DRAWING DESC.

TX

FACILITIES

HEREFORD

ERIC JOHNSON13955.114

CONCEPTUAL DESIGN

14

11/5

/202

1Da

te P

lott

ed:

K:\a

-f\BN

SF\1

3955

091\

_Her

efor

d_TX

_Re

plac

emen

t Dep

ot\0

4_Pr

oduc

tion\

01_C

AD\0

2_Sh

eets

\HER

ETX-

2021

-B-0

-E00

4.dw

gFi

le P

ath:

EAL

MJM

EBJ

MEP

70952

FACILITIES ENGINEERING

4515 KANSAS AVE.

KANSAS CITY, KS. 66106

5151 Mochel Drive, Suite 205

Downers Grove, IL 60515

Phone 630 499-4110

Fax 630 499-4119

tkda.com

DESIGN FIRM PROJ. MGR.

0 11/9/21 EBJ 30% ISSUE FOR BIDHERETX-2021-B-0-E004.dwg

LABELING DETAILS

E004

13

NOTES:

1. #4/0 BARE STRANDED COPPER GROUND

ELECTRODE CONDUCTOR. CONNECTIONS MADE IN/UNDER

CONCRETE OR INACCESSIBLE LOCATIONS SHALL BE

EXOTHERMICALLY WELDED.

2. GROUND RODS - 3/4"x10' COPPER WELD TYPE. PLACE IN

OPPOSITE CORNERS OF CONTAINMENT & EQUIPMENT PADS.

CONNECT TO GROUND GRID AS SHOWN.

3. IN TRANSFORMER PADS AND FREE STANDING EQUIPMENT PAD,

PROVIDE #4/0 BARE COPPER GROUND PIG TAIL. ROUTE THRU

PAD UP INTO EQUIPMENT COMPARTMENTS AND CONNECT TO

THE GROUND BAR OR BUS.

4. FOR CONTAINMENT GROUND RING, PROVIDE #4/0 COPPER

GROUND PIG TAIL. PROVIDE RMC LOOP OVER TOP EDGE OF PAD

AND BOND TO STEEL EQUIPMENT HOUSINGS.

5. REFER TO PLANS FOR ACTUAL PAD DIMENSIONS.

6. COORDINATE TRANSFORMER PAD AND WINDOWS WITH ACTUAL

EQUIPMENT FURNISHED AND UTILITY REQUIREMENTS.

7. REBAR / CONCRETE ENCASED ELECTRODE - CONNECT

TO GRID / BUILDING GROUND BAR WITH BARE #4/0 COPPER PIG

TAIL .

8. PROVIDE 20 FOOT MINIMUM SPACING BETWEEN GROUND RODS.

9. PROVIDE COPPER BONDING JUMPERS AS REQUIRED PER THE

NEC ARTICLE 250.

10. EQUIPMENT GROUNDING CONDUCTORS SHALL BE INSULATED

COPPER AND SIZED PER NEC ARTICLE 250 OR AS NOTED PER

THE PLANS.

11. SERVICE ENTRANCE NEUTRAL CONDUCTOR SHALL BE

INSULATED. SEE RISER OR CONDUIT SCHEDULE FOR SIZING.

12. GROUND ELECTRODE CONDUCTORS SHALL BE SIZED PER NEC

ARTICLE 250 OR AS NOTED PER THE PLANS.

13. ALL BENDS IN GROUNDING CONDUCTORS SHALL HAVE A 12" MIN.

RADIUS.

14. GROUND RODS SHALL NOT BE DRIVEN AT AN ANGLE OF MORE

THAN 30 DEGREES.

15. GROUNDING ELECTRODE CONDUCTORS SHALL BE INSTALLED IN

ONE CONTINUOUS LENGTH, WITHOUT SPLICES AND/OR JOINTS.

16. USE PVC CONDUIT TO PROTECT GROUND CABLE WHEN ROUTING

THROUGH CONCRETE, ASPHALT, OR ANY OTHER ABRASIVE

MATERIAL.

17. THE CONTRACTOR SHALL PROVIDE ALL MATERIALS REQUIRED

TO PROVIDE A COMPLETE GROUNDING SYSTEM PER THE

SPECIFICATIONS, DRAWINGS, AND NFPA NATIONAL ELECTRIC

CODE.

18. ALL AVAILABLE ELECTRODES SHALL BE CONNECTED TO

COMPLETE THE GROUNDING SYSTEM (IE. BUILDING STEEL,

CONCRETE ENCASED, WATER MAIN, GROUNDING RING, ETC.).

NOTES:

1.

2.

MAIN GROUND CABLE TO BE #4/0 AWG BARE COPPER.

TAPS TO BE #4/0 AWG UNLESS NOTED OTHERWISE.

GROUND CABLE TO BE BURIED A MINIMUM OF 30"

BELOW GRADE EXCEPT DIKED AREA.

CABLE TO REBAR

CABLE TO COLUMN

CABLE SPLICE

CABLE TO CABLE

NOTES:

1. MAIN GROUND RING CABLE TO BE #4/0 AWG BARE COPPER. TAPS TO BE

#4/0 AWG UNLESS NOTED OTHERWISE.

2. GROUND CABLE TO BE BURIED A MINIMUM OF 30" BELOW GRADE.

3. GROUND CONNECTIONS SHOWN ARE BASED ON ERICO CADWELD

PRODUCTS. EQUIVALENT EXOTHERMIC WELDS SHALL BE ACCEPTABLE

BONDING METHODS.

G G

GG

G

G G

G G

GG

R

R

R R

CONTAINMENT PAD TRANSFORMER PAD

2'-0" TYP

2'-0" TYP EW

CONTAINMENT PAD

GROUND ROD, TYPICAL

BUILDING

BUILDING

R R

G

GROUND ROD, TYPICAL

SEE DETAIL 1/E005

BUILDING GROUND BAR

SEE DETAIL 5/E005

STRUCTURAL STEEL

COLUMN, TYPICAL

SEE DETAIL 3/E005

GROUND ROD, TYPICAL

SEE DETAIL 1/E005

TYPICAL SUB PANEL

TYPICAL SEPARATELY

DERIVED SYSTEM

M

WATER

METER

NEUTRAL BUS

TYPICAL GROUND BUS

TELECOMM GROUND BAR

SEE DETAIL 5/E005

NEUTRAL BUS

SERVICE ENTRANCE

SWITCH GEAR /

PANELBOARD

TYPICAL

BONDING

JUMPER

BONDING

JUMPER

9

TYPICAL EQUIPMENT

BONDING JUMPER

SERVICE MAIN

BONDING JUMPER

TYPICAL

TRANSFORMER

10

11

12

10

12

7

CONDUIT

GROUND WIRE OR CABLE

#4/0 STRANDED

BARE COPPER

DUAL GROUND WIRE

ATTACHMENTS

3/4" X 10' GROUND ROD

(COPPERWELD)

USE SINGLE ATTACHMENT

FITTING FOR THIRD GROUND

CABLE ATTACHMENT

EXOTHERMIC WELD

GROUND ROD

GROUND ROD

GROUND WIRE

TYPICAL OF CADWELD "RJ"

CONNECTION. VERIFY SIZE

AND QUANTITY OF

TAPS FOR EACH FITTING.

TYPICAL OF CADWELD TYPE "SS"

FOR GROUNDING APPLICATIONS.

SPLICE SHALL BE APPROVED FOR

DIRECT BURIAL.

GROUNDING ELECTRODE

CONDUCTOR

STRUCTURAL STEEL COLUMN. VERIFY

WITH STRUCTURAL DRAWINGS FOR

COLUMN SIZE AND TYPE.

GROUNDING ELECTRODE CONDUCTOR

GROUND RING CONDUCTOR

TYPICAL OF CADWELD

TYPE "PC" CONNECTOR

GROUNDING ELECTRODE

CONDUCTOR

LOCKWASHER

INSULATING BUSHING

PLASTIC WASHER

1/4" X 2" COPPER

GROUND BAR

WALL MOUNTING

BRACKET

CADWELD TYPE

GT CONNECTION

GRADE

GROUND GRID

CONDUCTOR

5/16" HOT DIP GALVANIZED

STEEL COVER

1" DIA. LIFT HOLE AT

CENTER OF COVER

12" DIA. X 24"

GROUND ROD

LUG DISCONNECT TO VERTICAL STEEL

TYPE HM

TYPE GL

TWO HOLE LUG PREFERRED TO PREVENT

LOOSENING FROM TWISTING.

USING B121 OR B122 SERIES LUGS

GROUND WELL

SEE DETAIL 2/E005

NO SCALE

1

E005

GROUNDING DETAIL

NO SCALE

2

E005

GROUNDING WELL DETAIL

NO SCALE

3

E005

GROUNDING CONNECTIONS TYPICAL DETAIL

NO SCALE

5

E005

GROUND BAR DETAIL

NO SCALE

4

E005

EQUIPMENT, BUILDING AND TRANSFORMER PAD GROUNDING TYPICAL DETAILS

11

PIG TAIL

GG

G

R

9

10

11

12

7

10

Bar i

s one

inch

on

orig

inal

dra

win

g. If

not

one

inch

on

this

draw

ing,

adj

ust s

cale

s acc

ordi

ngly

.

DATENO. BY DESCRIPTION OF REVISIONS

SERVICE REQUISTION NO.:

STATE

PROJ. TYPE

STATION

FILENAME:

PROJ. DESC.

CHKD.

DES.

DRWN.

DESIGN FIRM PROJ. NO.

SHEET:

DRAWING NUMBER

OF

APPROVED

DRAWING DESC.

TX

FACILITIES

HEREFORD

ERIC JOHNSON13955.114

CONCEPTUAL DESIGN

14

11/5

/202

1Da

te P

lott

ed:

K:\a

-f\BN

SF\1

3955

091\

_Her

efor

d_TX

_Re

plac

emen

t Dep

ot\0

4_Pr

oduc

tion\

01_C

AD\0

2_Sh

eets

\HER

ETX-

2021

-B-0

-E00

5.dw

gFi

le P

ath:

EAL

MJM

EBJ

MEP

70952

FACILITIES ENGINEERING

4515 KANSAS AVE.

KANSAS CITY, KS. 66106

5151 Mochel Drive, Suite 205

Downers Grove, IL 60515

Phone 630 499-4110

Fax 630 499-4119

tkda.com

DESIGN FIRM PROJ. MGR.

0 11/9/21 EBJ 30% ISSUE FOR BIDHERETX-2021-B-0-E005.dwg

GROUNDING DETAILS

E005

14