1-877-QUANICS. www. qaunics .net. Single Container Advanced Treatment. Effluent Path. Applications. Single Family Residential Commercial Cluster/Community Sensitive Environments. Single Family Residential. Commercial. Cluster Community. Sensitive Environment. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: 1-877-QUANICS

1-877-QUANICS www.qaunics.net

Page 2: 1-877-QUANICS
Page 3: 1-877-QUANICS

Single Container Advanced Treatment

Page 4: 1-877-QUANICS
Page 5: 1-877-QUANICS

Effluent Path

Page 6: 1-877-QUANICS

Applications

• Single Family Residential

• Commercial

• Cluster/Community

• Sensitive Environments

Page 7: 1-877-QUANICS

Single Family Residential

Page 8: 1-877-QUANICS

Commercial

Page 9: 1-877-QUANICS

Cluster Community

Page 10: 1-877-QUANICS

Sensitive Environment

Actual effluent sample from NSF testing facility

Page 11: 1-877-QUANICS

Installation

Page 12: 1-877-QUANICS

Install the Zabel A300 Series Filter in the septic tank.

Pre-Treatment

Page 13: 1-877-QUANICS

Install Quanics Access Systems

Access System

Page 14: 1-877-QUANICS

Install the Quanics Filtered Pump Vault and STEP package

STEP System

Page 15: 1-877-QUANICS

Place the module on a level site. Aerocell can be carried into place. Bio-COIR must be moved with heavy equipment.

Pre-plumbed pipes are attached with

unions. The air vent is glued on.

Treatment Module

Page 16: 1-877-QUANICS

Connect piping

Treatment Module

Page 17: 1-877-QUANICS

Adjust the recirculation device and cover it up.After the effluent works its way through the SCAT system, it will go to the Recirculation Device. Adjust all the outlet openings by turning them so the levels are all equal. This is how you get the 80% back to the tank and the 20% to the drainfield.

Recirculation

Page 18: 1-877-QUANICS

Fill the septic tank and turn the pump on. Then set the pressure at the spray nozzles from 5-8 psi.

Set timer to design dose

Operation

Page 19: 1-877-QUANICS

• Septic Tank• Effluent Filter• Dosing system

• Treatment Module• Recirculation Device• Dispersal System

Maintenance (at six month intervals)

Page 20: 1-877-QUANICS

• The tank should be inspected for excessive scum and solids build-up. Determine the pumping frequency.

• Homeowners should be encouraged not to use excessive amounts of cleaners. Also, limit non-biodegradable materials such as grease, garbage disposal, personal hygiene products, chemicals, diapers, etc.

Septic Tank

Page 21: 1-877-QUANICS

• Inspect the septic tank effluent filter and clean as needed.

• Remove the filter plates on the pump vault and clean as needed.

• Installation and maintenance directions are included with the filter and pump vault.

Effluent Filter and Pump Vault

Page 22: 1-877-QUANICS

• Inspect wiring connections and control panel for proper operation. Correct as needed.

• Inspect floats for proper placement and make sure they are not tangled.

• Activate the pump through the panel or manually trip the floats to test for proper pump operation.

• Activate the alarm system to verify proper operation.

Dosing Systems

Page 23: 1-877-QUANICS

• A gray biomat on the media should be present and is normal. An excessive accumulation of solids may indicate that the septic tank is functioning poorly.

• If necessary, remove the upper layers of media and clean them by squeezing or rinsing. If you replace media, make sure it is compacted below the spray nozzles.

• Remove the spray nozzles by unclipping the clamp from the pipe. Clean of any debris and replace.

Treatment Modules

Page 24: 1-877-QUANICS

• If the recirculation system includes a pump, activate and check for proper operation.

• If the recirculation is by gravity, check by observing the discharge rates and adjust, if necessary by leveling.

Recirculation Devices

Page 25: 1-877-QUANICS

• If monitoring ports are installed, check the trenches for excessive ponding. Ponding may indicate poor soil, excessive water use or a timer that is not set properly.

• Inspect the overall system for signs of seepages or excessive vegetative growth. Determine the cause and make corrections.

Dispersal Systems

Page 26: 1-877-QUANICS

• Proper installation• Completed installation checklist• Completed operation checklist

Your Responsibility to Dealer

Page 27: 1-877-QUANICS

• Proper use of Quanics products• Proper installation of the system

Your Responsibility to Quanics

Page 28: 1-877-QUANICS

• Proper training• Warranty support• Promoting your professionalism