1 20-03-2013 «be-rf-pm» updates on thermal tests for clic prototype module type 0 ioannis...

16
1 20-03-2013 «BE-RF-PM» Updates on thermal tests for CLIC prototype module type 0 Ioannis Kossyvakis, Roberto Mondello, Fabrizio Rossi

Upload: darcy-harvey

Post on 12-Jan-2016

217 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: 1 20-03-2013 «BE-RF-PM» Updates on thermal tests for CLIC prototype module type 0 Ioannis Kossyvakis, Roberto Mondello, Fabrizio Rossi

120-03-2013 «BE-RF-PM»

Updates on thermal tests for

CLIC prototype module type 0

Ioannis Kossyvakis, Roberto Mondello, Fabrizio Rossi

Page 2: 1 20-03-2013 «BE-RF-PM» Updates on thermal tests for CLIC prototype module type 0 Ioannis Kossyvakis, Roberto Mondello, Fabrizio Rossi

220-03-2013 «BE-RF-PM»

2

2

Contents

1. Thermal test program

2. Position of temperature sensors

3. Data acquisition and LabVIEW software

4. Data analysis

Page 3: 1 20-03-2013 «BE-RF-PM» Updates on thermal tests for CLIC prototype module type 0 Ioannis Kossyvakis, Roberto Mondello, Fabrizio Rossi

320-03-2013 «BE-RF-PM»

3

3

Thermal test programSTEP #

INPUTOUTPUTTamb (°C) vair (m/s) Heat power (%) Ti,water (°C)

To,water (°C)SAS AS Load PETS RFN Load DBQ SAS (+10 °C) PETS (+15 °C)

0

1

20

0.1

0 0 0 01. WPS system (study influence of

vibrations induced by air speed on WPS measuring system)

2 0.23 0.34 0.45 0.56 0.67 0.78 0.8

11 20

0.3 0 0 0 0 1. Temperature sensors2. Alignment2 30

3 40

2

1

200.4

50 500

25

30

0 1. Temperature sensors2. Alignment

2 100 100 353

0.850 50

030

4 100 100 355

400.4

50 500

306 100 100 357

0.850 50

030

8 100 100 35

3

1

200.4 0

50 50 50

25 0

32.5

1. Temperature sensors2. Alignment

2 100 100 100 403

0.8 050 50 50 32.5

4 100 100 100 405

400.4 0

50 50 50 32.56 100 100 100 407

0.8 050 50 50 32.5

8 100 100 100 40

4

1

200.4

50

25

30 32.5

1. Temperature sensors2. Alignment

2 100 35 403

0.850 30 32.5

4 100 35 405

400.4

50 30 32.56 100 35 407

0.850 30 32.5

8 100 35 40

Page 4: 1 20-03-2013 «BE-RF-PM» Updates on thermal tests for CLIC prototype module type 0 Ioannis Kossyvakis, Roberto Mondello, Fabrizio Rossi

420-03-2013 «BE-RF-PM»

4

4

Temperature sensors : SAS #1 + CL

TS1

TS2 TS3 TS4 TS5 TS6

TS7

TS29.C

TS29.ATS29.B

TS29.D

Thermocouples type J• Material: Fe/CuNi• Accuracy = ± 1.5 °C

RTD sensor• PT 100 (4-wire resistance)• Accuracy = ± 0.1 °C

Page 5: 1 20-03-2013 «BE-RF-PM» Updates on thermal tests for CLIC prototype module type 0 Ioannis Kossyvakis, Roberto Mondello, Fabrizio Rossi

520-03-2013 «BE-RF-PM»

5

5

Temperature sensors : SAS #2 + CL

TS8

TS9

TS10

TS30.C

TS30.ATS30.B

TS30.D

Thermocouples type J• Material: Fe/CuNi• Accuracy = ± 1.5 °C

RTD sensor• PT 100 (4-wire resistance)• Accuracy = ± 0.1 °C

Page 6: 1 20-03-2013 «BE-RF-PM» Updates on thermal tests for CLIC prototype module type 0 Ioannis Kossyvakis, Roberto Mondello, Fabrizio Rossi

620-03-2013 «BE-RF-PM»

6

6

Temperature sensors : PETS + RF NETWORK + CL

TS23

TS17

TS18

TS19

TS20

TS21

TS22

TS24

TS25

TS26

TS36

TS35

TS34

TS33RTD sensor• PT 100 (4-wire resistance)• Accuracy = ± 0.1 °C

Thermocouples type J• Material: Fe/CuNi• Accuracy = ± 1.5 °C

Page 7: 1 20-03-2013 «BE-RF-PM» Updates on thermal tests for CLIC prototype module type 0 Ioannis Kossyvakis, Roberto Mondello, Fabrizio Rossi

720-03-2013 «BE-RF-PM»

7

7

Temperature sensors : DBQ

TS27

TS28

RTD sensor• PT 100 (4-wire resistance)• Accuracy = ± 0.1 °C

Page 8: 1 20-03-2013 «BE-RF-PM» Updates on thermal tests for CLIC prototype module type 0 Ioannis Kossyvakis, Roberto Mondello, Fabrizio Rossi

820-03-2013 «BE-RF-PM»

8

8

Temperature sensors : air temperature

1222

1339

650

770

275

245

200

TS39

TS41

TS38 TS40TS42

189

979

979

TS43 TS45TS44

TS38 TS40TS39

TS48 TS50TS49AIR TEMPERATURE AROUND TM0• 3 cross sections• 5 thermocouples type T for each cross section

Thermocouples type T• Material: Cu/CuNi• Accuracy = ± 0.5 °C

Page 9: 1 20-03-2013 «BE-RF-PM» Updates on thermal tests for CLIC prototype module type 0 Ioannis Kossyvakis, Roberto Mondello, Fabrizio Rossi

920-03-2013 «BE-RF-PM»

9

9

Temperature sensors (pictures in the lab)

Temperature sensors on the air

Temperature sensors on the accelerating structures

Temperature sensors on the DB Q and PETS

Temperature sensors on the waveguides

Page 10: 1 20-03-2013 «BE-RF-PM» Updates on thermal tests for CLIC prototype module type 0 Ioannis Kossyvakis, Roberto Mondello, Fabrizio Rossi

1020-03-2013 «BE-RF-PM»

10

10

Data acquisition and LabVIEW softwareData acquisition from the

accelerating structures Data acquisition from the waveguides

Data acquisition from the PETS

Data acquisition from the magnets

Page 11: 1 20-03-2013 «BE-RF-PM» Updates on thermal tests for CLIC prototype module type 0 Ioannis Kossyvakis, Roberto Mondello, Fabrizio Rossi

1120-03-2013 «BE-RF-PM»

11

11

Data acquisition and LabVIEW software

Data acquisition from the air

thermocouples

Real time plots

Steady state condition at

40 oC

Page 12: 1 20-03-2013 «BE-RF-PM» Updates on thermal tests for CLIC prototype module type 0 Ioannis Kossyvakis, Roberto Mondello, Fabrizio Rossi

1220-03-2013 «BE-RF-PM»

12

12

Data analysis (20 oC)

Super AS - 1 PETS - 1

DB Q - 1 Air thermocouples - 1

Page 13: 1 20-03-2013 «BE-RF-PM» Updates on thermal tests for CLIC prototype module type 0 Ioannis Kossyvakis, Roberto Mondello, Fabrizio Rossi

1320-03-2013 «BE-RF-PM»

13

13

Data analysis (from 20 oC to 30 oC)

Super AS - 1 PETS - 1

DB Q - 1 Air thermocouples - 1

Page 14: 1 20-03-2013 «BE-RF-PM» Updates on thermal tests for CLIC prototype module type 0 Ioannis Kossyvakis, Roberto Mondello, Fabrizio Rossi

1420-03-2013 «BE-RF-PM»

14

14

Data analysis (30 oC)

Super AS - 1 PETS - 1

DB Q - 1 Air thermocouples - 1

Page 15: 1 20-03-2013 «BE-RF-PM» Updates on thermal tests for CLIC prototype module type 0 Ioannis Kossyvakis, Roberto Mondello, Fabrizio Rossi

1520-03-2013 «BE-RF-PM»

15

15

Data analysis (from 30 oC to 40 oC)

Super AS - 1 PETS - 1

DB Q - 1 Air thermocouples - 1

Page 16: 1 20-03-2013 «BE-RF-PM» Updates on thermal tests for CLIC prototype module type 0 Ioannis Kossyvakis, Roberto Mondello, Fabrizio Rossi

1620-03-2013 «BE-RF-PM»

16

16

Data analysis (effect of air speed on air temperature: 0.8 m/s 0.3 m/s)

Air thermocouples - 3

Air thermocouples - 1 Air thermocouples - 2