1 2 3 4 expansion · psp-miph-a01 sns20.3.171:2 @ a3 approved-600 max.1800 maximum length with...
TRANSCRIPT
Typical Panel Fixing
Arrangement
Drwg. No.:
Client:
Project:
Title:
Rev Details
Drawn by:Date: Scale:
All Saints Industrial Estate
Shildon
County Durham
DL4 2RD
Tel:
Fax:
Email:
www.pspuk.com
00 44 (0) 1388 770490
00 44 (0) 1388 778068
Unit 11
Status:
Revision:
Date
Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the
specification compliance for each project, PSP will not be held responsible for any project non conformities.
DO NOT SCALE IF IN DOUBT - ASK
PSP SYSTEM - Matrix IPH
Matrix IPH Standard Details
P.S.P.
PSP-MIPH-A01
sns20.3.17
1:2 @ A3
Approved
-
6
0
0
M
A
X
.
1
8
0
0
M
A
X
I
M
U
M
L
E
N
G
T
H
W
I
T
H
D
I
R
E
C
T
F
I
X
I
N
G
S
E
X
P
A
N
S
I
O
N
E
X
P
A
N
S
I
O
N
6
0
0
M
A
X
.
6
0
0
M
A
X
.
6
0
0
M
A
X
.
G
R
A
I
N
ISOMETRIC VIEW OF TYPICAL
PANEL FIXING ARRANGEMENT
P
A
N
E
L
S
U
N
D
E
R
1
8
0
0
L
G
F
I
X
E
D
D
I
R
E
C
T
L
Y
T
O
V
E
R
T
I
C
A
L
C
A
R
R
I
E
R
S
.
P
A
N
E
L
S
O
V
E
R
1
8
0
0
L
G
F
I
X
E
D
D
I
R
E
C
T
L
Y
I
N
C
E
N
T
R
A
L
A
R
E
A
&
W
I
T
H
F
I
X
I
N
G
C
L
I
P
S
@
P
A
N
E
L
E
N
D
S
.
(HORIZONTALLY LAID)
OP
TIO
NA
L E
ND
R
ET
UR
N
OM
IT
TE
D F
OR
C
LA
RIT
Y
3
1
24
7
24
JOINTS SIZE - PROJECT SPECIFIC;
STANDARD Matrix IPH JOINTS
ARE 5mm, 10mm, 15mm & 20mm
ITEM 24: STAINLESS STEEL FIXING CLIP
Optional colour matched cover trim
Stainless steel fixing (TBC)
8
Insulation by others
Cement particle board by others
Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max
5
6
4
1
2
3
PARTS LIST
7
9
10
11
Internal boards by others
12
Breather membrane by others
13
Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm
14
15
Additional rigid sheet insulation if required by others
16
JT4-4-4.8x19 Stainless steel fixing
JT4-6-5.5x22 A14 Stainless steel fixing
Optional PVC thermal break, 5mm
17
SFS support structure by others
18
19
20
21
22
'Top hat' profile (optional)
Aluminium flashing (Jamb/Head/Coping/Drip)
23
Fire / Smoke Barrier and fittings by others
24
EPDM by others
25
26
Weather seal by others
27
Aluminium carrier bracket, 3mm thick
Internal / External corner flashing
Stainless Steel Fixing Clip
Support Angle
Adjacent Window / Door Profile
Fixing bracket
Corner support angle (factory assembled)
Optional Ventilation profile / insect mesh
Removable panel (replacement procedure ref to PSP-MIPH-S10)
Drwg. No.:
Client:
Project:
Title:
Rev Details
Drawn by:Date: Scale:
All Saints Industrial Estate
Shildon
County Durham
DL4 2RD
Tel:
Fax:
Email:
www.pspuk.com
00 44 (0) 1388 770490
00 44 (0) 1388 778068
Unit 11
Status:
Revision:
Date
Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the
specification compliance for each project, PSP will not be held responsible for any project non conformities.
DO NOT SCALE IF IN DOUBT - ASK
PSP SYSTEM - Matrix IPH
Matrix IPH Standard Details
P.S.P.
PSP-MIPH-A02
sns20.3.17
1:2 @ A3
Approved
-
Typical Panel Section
LAY
51
OVERALL PANEL FACE SIZE
'Y'
'X' VARIES TO
SUIT JOINT WIDTH
LINE OF END RETURN (OPTIONAL
STANDARD 'X' & 'Y' DIMENSIONS
JOINT WIDTH DIM 'X' DIM 'Y' MIN. DIM 'Y' MAX.
5mm 15mm 185mm 685mm
10mm 20mm 180mm 680mm
15mm 25mm 175mm 675mm
20mm 30mm 170mm 670mm
(DATUM EDGE)
(If Stainless Steel Fixing Clip to be used)
TYPICAL PANEL SECTION
ROLLFORM PLANK
1
57
(Standard Joint)
Optional colour matched cover trim
Stainless steel fixing (TBC)
8
Insulation by others
Cement particle board by others
Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max
5
6
4
1
2
3
PARTS LIST
7
9
10
11
Internal boards by others
12
Breather membrane by others
13
Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm
14
15
Additional rigid sheet insulation if required by others
16
JT4-4-4.8x19 Stainless steel fixing
JT4-6-5.5x22 A14 Stainless steel fixing
Optional PVC thermal break, 5mm
17
SFS support structure by others
18
19
20
21
22
'Top hat' profile (optional)
Aluminium flashing (Jamb/Head/Coping/Drip)
23
Fire / Smoke Barrier and fittings by others
24
EPDM by others
25
26
Weather seal by others
27
Aluminium carrier bracket, 3mm thick
Internal / External corner flashing
Stainless Steel Fixing Clip
Support Angle
Adjacent Window / Door Profile
Fixing bracket
Corner support angle (factory assembled)
Optional Ventilation profile / insect mesh
Removable panel (replacement procedure ref to PSP-MIPH-S10)
JOINTS SIZE - PROJECT SPECIFIC;
STANDARD Matrix IPH JOINTS
ARE 5mm, 10mm, 15mm & 20mm
Typical Double Female Panel
Section
Drwg. No.:
Client:
Project:
Title:
Rev Details
Drawn by:Date: Scale:
All Saints Industrial Estate
Shildon
County Durham
DL4 2RD
Tel:
Fax:
Email:
www.pspuk.com
00 44 (0) 1388 770490
00 44 (0) 1388 778068
Unit 11
Status:
Revision:
Date
Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the
specification compliance for each project, PSP will not be held responsible for any project non conformities.
DO NOT SCALE IF IN DOUBT - ASK
PSP SYSTEM - Matrix IPH
Matrix IPH Standard Details
P.S.P.
PSP-MIPH-A03
sns20.3.17
1:2 @ A3
Approved
-
JOINTS SIZE - PROJECT SPECIFIC;
STANDARD Matrix IPH JOINTS
ARE 5mm, 10mm, 15mm & 20mm
Optional colour matched cover trim
Stainless steel fixing (TBC)
8
Insulation by others
Cement particle board by others
Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max
5
6
4
1
2
3
PARTS LIST
7
9
10
11
Internal boards by others
12
Breather membrane by others
13
Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm
14
15
Additional rigid sheet insulation if required by others
16
JT4-4-4.8x19 Stainless steel fixing
JT4-6-5.5x22 A14 Stainless steel fixing
Optional PVC thermal break, 5mm
17
SFS support structure by others
18
19
20
21
22
'Top hat' profile (optional)
Aluminium flashing (Jamb/Head/Coping/Drip)
23
Fire / Smoke Barrier and fittings by others
24
EPDM by others
25
26
Weather seal by others
27
Aluminium carrier bracket, 3mm thick
Internal / External corner flashing
Stainless Steel Fixing Clip
Support Angle
Adjacent Window / Door Profile
Fixing bracket
Corner support angle (factory assembled)
Optional Ventilation profile / insect mesh
Removable panel (replacement procedure ref to PSP-MIPH-S10)
51
OVERALL PANEL FACE SIZE
LINE OF END RETURN (OPTIONAL)
51
1
TYPICAL DOUBLE FEMALE PANEL SECTION
ROLLFORM PLANK
(If Stainless Steel Fixing Clip to be used)
57
(Standard Joint)
(If Stainless Steel Fixing Clip to be used)
57
(Standard Joint)
Typical Double Male Panel Section
Drwg. No.:
Client:
Project:
Title:
Rev Details
Drawn by:Date: Scale:
All Saints Industrial Estate
Shildon
County Durham
DL4 2RD
Tel:
Fax:
Email:
www.pspuk.com
00 44 (0) 1388 770490
00 44 (0) 1388 778068
Unit 11
Status:
Revision:
Date
Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the
specification compliance for each project, PSP will not be held responsible for any project non conformities.
DO NOT SCALE IF IN DOUBT - ASK
PSP SYSTEM - Matrix IPH
Matrix IPH Standard Details
P.S.P.
PSP-MIPH-A04
sns20.3.17
1:2 @ A3
Approved
-
JOINTS SIZE - PROJECT SPECIFIC;
STANDARD Matrix IPH JOINTS
ARE 5mm, 10mm, 15mm & 20mm
Optional colour matched cover trim
Stainless steel fixing (TBC)
8
Insulation by others
Cement particle board by others
Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max
5
6
4
1
2
3
PARTS LIST
7
9
10
11
Internal boards by others
12
Breather membrane by others
13
Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm
14
15
Additional rigid sheet insulation if required by others
16
JT4-4-4.8x19 Stainless steel fixing
JT4-6-5.5x22 A14 Stainless steel fixing
Optional PVC thermal break, 5mm
17
SFS support structure by others
18
19
20
21
22
'Top hat' profile (optional)
Aluminium flashing (Jamb/Head/Coping/Drip)
23
Fire / Smoke Barrier and fittings by others
24
EPDM by others
25
26
Weather seal by others
27
Aluminium carrier bracket, 3mm thick
Internal / External corner flashing
Stainless Steel Fixing Clip
Support Angle
Adjacent Window / Door Profile
Fixing bracket
Corner support angle (factory assembled)
Optional Ventilation profile / insect mesh
Removable panel (replacement procedure ref to PSP-MIPH-S10)
TYPICAL DOUBLE MALE PANEL SECTION
ROLLFORM PLANK
OVERALL PANEL FACE SIZE
VARIES TO
SUIT JOINT WIDTH
LINE OF END RETURN (OPTIONAL)
1
Drwg. No.:
Client:
Project:
Title:
Rev Details
Drawn by:Date: Scale:
All Saints Industrial Estate
Shildon
County Durham
DL4 2RD
Tel:
Fax:
Email:
www.pspuk.com
00 44 (0) 1388 770490
00 44 (0) 1388 778068
Unit 11
Status:
Revision:
Date
Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the
specification compliance for each project, PSP will not be held responsible for any project non conformities.
DO NOT SCALE IF IN DOUBT - ASK
TYPICAL BRACKET ARRANGEMENT
Fixed point
bracket
Sliding point
bracket
Sliding point
bracket
Sliding point
bracket
Fixed point
bracket
Sliding point
bracket
FIXED POINT BRACKET
SLIDING POINT BRACKET
absorb wind loading and allow for expansion and contraction
absorb both vertical dead loads
min 10m
m
PSP SYSTEM - Matrix IPH
Matrix IPH Standard Details
P.S.P.
PSP-MIPH-A05
sns 20.3.17 1:2 @ A3
Approved
-
Fixed & Sliding Brackets
Points Setting Out
Drwg. No.:
Client:
Project:
Title:
Rev Details
Drawn by:Date: Scale:
All Saints Industrial Estate
Shildon
County Durham
DL4 2RD
Tel:
Fax:
Email:
www.pspuk.com
00 44 (0) 1388 770490
00 44 (0) 1388 778068
Unit 11
Status:
Revision:
Date
Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the
specification compliance for each project, PSP will not be held responsible for any project non conformities.
DO NOT SCALE IF IN DOUBT - ASK
PSP SYSTEM - Matrix IPH
Matrix IPH Standard Details
P.S.P.
PSP-MIPH-P01
sns9.3.17
1:2 @ A3
Approved
-
Vertical Panel Joint Detail
(Plan View - under 1800mm)
de
f
VERTICAL PANEL JOINT DETAIL
9 10 12 11
1 2
5 13
cb
module length module length
3 4 76
14
N
N
LEGEND:
part of system, provided by PSP
provided by others
N
not part of system, can be provided by PSP
8
STANDARD MATRIX-IP VERTICAL &
HORIZONTAL JOINTS ARE 20mm
a
20mm nominal
24
20
Optional end folds
a PSP Panel thickness - 24mm
LEGEND
b
c
d
e
f
Insulation by others (must be Part B Compliant)
CP board by others - thickness established by project specification
SFS by others - depth established by project specification
Internal finishes by others
Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)
and 50mm (open joints)
Optional colour matched cover trim
Stainless steel fixing (TBC)
8
Insulation by others
Cement particle board by others
Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max
5
6
4
1
2
3
PARTS LIST
7
9
10
11
Internal boards by others
12
Breather membrane by others
13
Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm
14
15
Additional rigid sheet insulation if required by others
16
JT4-4-4.8x19 Stainless steel fixing
JT4-6-5.5x22 A14 Stainless steel fixing
Optional PVC thermal break, 5mm
17
SFS support structure by others
18
19
20
21
22
'Top hat' profile (optional)
Aluminium flashing (Jamb/Head/Coping/Drip)
23
Fire / Smoke Barrier and fittings by others
24
EPDM by others
25
26
Weather seal by others
27
Aluminium carrier bracket, 3mm thick
Internal / External corner flashing
Stainless Steel Fixing Clip
Support Angle
Adjacent Window / Door Profile
Fixing bracket
Corner support angle (factory assembled)
Optional Ventilation profile / insect mesh
Removable panel (replacement procedure ref to PSP-MIPH-S10)
de
fc
b
Drwg. No.:
Client:
Project:
Title:
Rev Details
Drawn by:Date: Scale:
All Saints Industrial Estate
Shildon
County Durham
DL4 2RD
Tel:
Fax:
Email:
www.pspuk.com
00 44 (0) 1388 770490
00 44 (0) 1388 778068
Unit 11
Status:
Revision:
Date
Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the
specification compliance for each project, PSP will not be held responsible for any project non conformities.
DO NOT SCALE IF IN DOUBT - ASK
P.S.P.
sns 1:2 @ A3
Approved
-
N
N
LEGEND:
part of system, provided by PSP
provided by others
N
not part of system, can be provided by PSP
STANDARD MATRIX-IP VERTICAL &
HORIZONTAL JOINTS ARE 20mm
VERTICAL PANEL JOINT DETAIL
(over 1800mm)
ITEM 24: STAINLESS STEEL FIXING CLIP
a
20mm nominal
24
9 10 12 115 13 14
8
1 23 4 76
a PSP Panel thickness - 24mm
LEGEND
b
c
d
e
f
Insulation by others (must be Part B Compliant)
CP board by others - thickness established by project specification
SFS by others - depth established by project specification
Internal finishes by others
Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)
and 50mm (open joints)
Optional colour matched cover trim
Stainless steel fixing (TBC)
8
Insulation by others
Cement particle board by others
Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max
5
6
4
1
2
3
PARTS LIST
7
9
10
11
Internal boards by others
12
Breather membrane by others
13
Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm
14
15
Additional rigid sheet insulation if required by others
16
JT4-4-4.8x19 Stainless steel fixing
JT4-6-5.5x22 A14 Stainless steel fixing
Optional PVC thermal break, 5mm
17
SFS support structure by others
18
19
20
21
22
'Top hat' profile (optional)
Aluminium flashing (Jamb/Head/Coping/Drip)
23
Fire / Smoke Barrier and fittings by others
24
EPDM by others
25
26
Weather seal by others
27
Aluminium carrier bracket, 3mm thick
Internal / External corner flashing
Stainless Steel Fixing Clip
Support Angle
Adjacent Window / Door Profile
Fixing bracket
Corner support angle (factory assembled)
Optional Ventilation profile / insect mesh
Removable panel (replacement procedure ref to PSP-MIPH-S10)
24
PSP SYSTEM - Matrix IPH
Matrix IPH Standard Details
PSP-MIPH-P02
9.3.17
Vertical Panel Joint Detail
(Plan View - over 1800mm)
de
fc
b
Drwg. No.:
Client:
Project:
Title:
Rev Details
Drawn by:Date: Scale:
All Saints Industrial Estate
Shildon
County Durham
DL4 2RD
Tel:
Fax:
Email:
www.pspuk.com
00 44 (0) 1388 770490
00 44 (0) 1388 778068
Unit 11
Status:
Revision:
Date
Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the
specification compliance for each project, PSP will not be held responsible for any project non conformities.
DO NOT SCALE IF IN DOUBT - ASK
P.S.P.
sns 1:2 @ A3
Approved
N
N
LEGEND:
part of system, provided by PSP
provided by others
N
not part of system, can be provided by PSP
STANDARD MATRIX-IP VERTICAL &
HORIZONTAL JOINTS ARE 20mm
a
24
9 10 12 115 13 14
8
1 23 76
a PSP Panel thickness - 24mm
LEGEND
b
c
d
e
f
Insulation by others (must be Part B Compliant)
CP board by others - thickness established by project specification
SFS by others - depth established by project specification
Internal finishes by others
Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)
and 50mm (open joints)
Optional colour matched cover trim
Stainless steel fixing (TBC)
8
Insulation by others
Cement particle board by others
Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max
5
6
4
1
2
3
PARTS LIST
7
9
10
11
Internal boards by others
12
Breather membrane by others
13
Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm
14
15
Additional rigid sheet insulation if required by others
16
JT4-4-4.8x19 Stainless steel fixing
JT4-6-5.5x22 A14 Stainless steel fixing
Optional PVC thermal break, 5mm
17
SFS support structure by others
18
19
20
21
22
'Top hat' profile (optional)
Aluminium flashing (Jamb/Head/Coping/Drip)
23
Fire / Smoke Barrier and fittings by others
24
EPDM by others
25
26
Weather seal by others
27
Aluminium carrier bracket, 3mm thick
Internal / External corner flashing
Stainless Steel Fixing Clip
Support Angle
Adjacent Window / Door Profile
Fixing bracket
Corner support angle (factory assembled)
Optional Ventilation profile / insect mesh
Removable panel (replacement procedure ref to PSP-MIPH-S10)
PSP SYSTEM - Matrix IPH
Matrix IPH Standard Details
9.3.17
Vertical Midspan Support Detail
PSP-MIPH-P03
EXTERNAL CORNER PANEL DETAIL
20m
m nom
inal
1
3
4
7
6
8 11 9 10 13
12
14
d e fcb
2
5
Maximum corner
length to suit
material availability
Drwg. No.:
Client:
Project:
Title:
Rev Details
Drawn by:Date: Scale:
All Saints Industrial Estate
Shildon
County Durham
DL4 2RD
Tel:
Fax:
Email:
www.pspuk.com
00 44 (0) 1388 770490
00 44 (0) 1388 778068
Unit 11
Status:
Revision:
Date
Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the
specification compliance for each project, PSP will not be held responsible for any project non conformities.
DO NOT SCALE IF IN DOUBT - ASK
PSP SYSTEM - Matrix IPH
Matrix IPH Standard Details
P.S.P.
PSP-MIPH-P04
sns 10.3.17 1:2 @ A3
Approved
-
External Corner Panel Detail
(Plan View)
N
N
LEGEND:
part of system, provided by PSP
provided by others
N
not part of system, can be provided by PSP
STANDARD MATRIX-IP VERTICAL &
HORIZONTAL JOINTS ARE 20mm
20mm nominal
a
additional bracket required
if larger 400mm
24
FA
CT
OR
Y M
IT
RE
D C
OR
NE
R
a PSP Panel thickness - 24mm
LEGEND
b
c
d
e
f
Insulation by others (must be Part B Compliant)
CP board by others - thickness established by project specification
SFS by others - depth established by project specification
Internal finishes by others
Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)
and 50mm (open joints)
Optional colour matched cover trim
Stainless steel fixing (TBC)
8
Insulation by others
Cement particle board by others
Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max
5
6
4
1
2
3
PARTS LIST
7
9
10
11
Internal boards by others
12
Breather membrane by others
13
Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm
14
15
Additional rigid sheet insulation if required by others
16
JT4-4-4.8x19 Stainless steel fixing
JT4-6-5.5x22 A14 Stainless steel fixing
Optional PVC thermal break, 5mm
17
SFS support structure by others
18
19
20
21
22
'Top hat' profile (optional)
Aluminium flashing (Jamb/Head/Coping/Drip)
23
Fire / Smoke Barrier and fittings by others
24
EPDM by others
25
26
Weather seal by others
27
Aluminium carrier bracket, 3mm thick
Internal / External corner flashing
Stainless Steel Fixing Clip
Support Angle
Adjacent Window / Door Profile
Fixing bracket
Corner support angle (factory assembled)
Optional Ventilation profile / insect mesh
Removable panel (replacement procedure ref to PSP-MIPH-S10)
18
18
20m
m nom
inal
23
EXTERNAL CORNER FLASHING DETAIL
Maximum corner
length to suit
material availability
Drwg. No.:
Client:
Project:
Title:
Rev Details
Drawn by:Date: Scale:
All Saints Industrial Estate
Shildon
County Durham
DL4 2RD
Tel:
Fax:
Email:
www.pspuk.com
00 44 (0) 1388 770490
00 44 (0) 1388 778068
Unit 11
Status:
Revision:
Date
Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the
specification compliance for each project, PSP will not be held responsible for any project non conformities.
DO NOT SCALE IF IN DOUBT - ASK
PSP SYSTEM - Matrix IPH
Matrix IPH Standard Details
P.S.P.
PSP-MIPH-P05
sns 10.3.17 1:2 @ A3
Approved
-
External Corner Flashing Detail
(Plan View)
N
N
LEGEND:
part of system, provided by PSP
provided by others
N
not part of system, can be provided by PSP
20mm nominal
24
20mm nominal
additional bracket required
if larger 400mm
24
8 2
1
3
7
6
12
14
5
11 9 10 13
STANDARD MATRIX-IP VERTICAL &
HORIZONTAL JOINTS ARE 20mm
a PSP Panel thickness - 24mm
LEGEND
b
c
d
e
f
Insulation by others (must be Part B Compliant)
CP board by others - thickness established by project specification
SFS by others - depth established by project specification
Internal finishes by others
Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)
and 50mm (open joints)
Optional colour matched cover trim
Stainless steel fixing (TBC)
8
Insulation by others
Cement particle board by others
Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max
5
6
4
1
2
3
PARTS LIST
7
9
10
11
Internal boards by others
12
Breather membrane by others
13
Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm
14
15
Additional rigid sheet insulation if required by others
16
JT4-4-4.8x19 Stainless steel fixing
JT4-6-5.5x22 A14 Stainless steel fixing
Optional PVC thermal break, 5mm
17
SFS support structure by others
18
19
20
21
22
'Top hat' profile (optional)
Aluminium flashing (Jamb/Head/Coping/Drip)
23
Fire / Smoke Barrier and fittings by others
24
EPDM by others
25
26
Weather seal by others
27
Aluminium carrier bracket, 3mm thick
Internal / External corner flashing
Stainless Steel Fixing Clip
Support Angle
Adjacent Window / Door Profile
Fixing bracket
Corner support angle (factory assembled)
Optional Ventilation profile / insect mesh
Removable panel (replacement procedure ref to PSP-MIPH-S10)
18
18
def c b a
9
12
5
10
11
13
14
1
3
7
2
3
8
6
Drwg. No.:
Client:
Project:
Title:
Rev Details
Drawn by:Date: Scale:
All Saints Industrial Estate
Shildon
County Durham
DL4 2RD
Tel:
Fax:
Email:
www.pspuk.com
00 44 (0) 1388 770490
00 44 (0) 1388 778068
Unit 11
Status:
Revision:
Date
Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the
specification compliance for each project, PSP will not be held responsible for any project non conformities.
DO NOT SCALE IF IN DOUBT - ASK
PSP SYSTEM - Matrix IPH
Matrix IPH Standard Details
P.S.P.
PSP-MIPH-P06
sns 10.3.17 1:2 @ A3
Approved
-
Internal Corner Detail
(Plan View)
N
N
LEGEND:
part of system, provided by PSP
provided by others
N
not part of system, can be provided by PSP
INTERNAL CORNER DETAIL
20m
m m
in
23
a PSP Panel thickness - 24mm
LEGEND
b
c
d
e
f
Insulation by others (must be Part B Compliant)
CP board by others - thickness established by project specification
SFS by others - depth established by project specification
Internal finishes by others
Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)
and 50mm (open joints)
Optional colour matched cover trim
Stainless steel fixing (TBC)
8
Insulation by others
Cement particle board by others
Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max
5
6
4
1
2
3
PARTS LIST
7
9
10
11
Internal boards by others
12
Breather membrane by others
13
Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm
14
15
Additional rigid sheet insulation if required by others
16
JT4-4-4.8x19 Stainless steel fixing
JT4-6-5.5x22 A14 Stainless steel fixing
Optional PVC thermal break, 5mm
17
SFS support structure by others
18
19
20
21
22
'Top hat' profile (optional)
Aluminium flashing (Jamb/Head/Coping/Drip)
23
Fire / Smoke Barrier and fittings by others
24
EPDM by others
25
26
Weather seal by others
27
Aluminium carrier bracket, 3mm thick
Internal / External corner flashing
Stainless Steel Fixing Clip
Support Angle
Adjacent Window / Door Profile
Fixing bracket
Corner support angle (factory assembled)
Optional Ventilation profile / insect mesh
Removable panel (replacement procedure ref to PSP-MIPH-S10)
STANDARD MATRIX-IP VERTICAL &
HORIZONTAL JOINTS ARE 20mm
18
18
BRICKWORK ABUTMENT DETAIL
c
9 101211 5
20mm min
137
8 13
6
2
Drwg. No.:
Client:
Project:
Title:
Rev Details
Drawn by:Date: Scale:
All Saints Industrial Estate
Shildon
County Durham
DL4 2RD
Tel:
Fax:
Email:
www.pspuk.com
00 44 (0) 1388 770490
00 44 (0) 1388 778068
Unit 11
Status:
Revision:
Date
Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the
specification compliance for each project, PSP will not be held responsible for any project non conformities.
DO NOT SCALE IF IN DOUBT - ASK
PSP SYSTEM - Matrix IPH
Matrix IPH Standard Details
P.S.P.
PSP-MIPH-P07
sns 10.3.17 1:2 @ A3
Approved
-
Brickwork Abutment Detail
(Plan View)
N
N
LEGEND:
part of system, provided by PSP
provided by others
N
not part of system, can be provided by PSP
4
ad
ef
cb
a
a PSP Panel thickness - 24mm
LEGEND
b
c
d
e
f
Insulation by others (must be Part B Compliant)
CP board by others - thickness established by project specification
SFS by others - depth established by project specification
Internal finishes by others
Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)
and 50mm (open joints)
Optional colour matched cover trim
Stainless steel fixing (TBC)
8
Insulation by others
Cement particle board by others
Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max
5
6
4
1
2
3
PARTS LIST
7
9
10
11
Internal boards by others
12
Breather membrane by others
13
Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm
14
15
Additional rigid sheet insulation if required by others
16
JT4-4-4.8x19 Stainless steel fixing
JT4-6-5.5x22 A14 Stainless steel fixing
Optional PVC thermal break, 5mm
17
SFS support structure by others
18
19
20
21
22
'Top hat' profile (optional)
Aluminium flashing (Jamb/Head/Coping/Drip)
23
Fire / Smoke Barrier and fittings by others
24
EPDM by others
25
26
Weather seal by others
27
Aluminium carrier bracket, 3mm thick
Internal / External corner flashing
Stainless Steel Fixing Clip
Support Angle
Adjacent Window / Door Profile
Fixing bracket
Corner support angle (factory assembled)
Optional Ventilation profile / insect mesh
Removable panel (replacement procedure ref to PSP-MIPH-S10)
STANDARD MATRIX-IP VERTICAL &
HORIZONTAL JOINTS ARE 20mm
WINDOW JAMB DETAIL
9 1011 5
17
21
19
1
module length
2 3 7
6
de
fc
b
14
813
Drwg. No.:
Client:
Project:
Title:
Rev Details
Drawn by:Date: Scale:
All Saints Industrial Estate
Shildon
County Durham
DL4 2RD
Tel:
Fax:
Email:
www.pspuk.com
00 44 (0) 1388 770490
00 44 (0) 1388 778068
Unit 11
Status:
Revision:
Date
Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the
specification compliance for each project, PSP will not be held responsible for any project non conformities.
DO NOT SCALE IF IN DOUBT - ASK
PSP SYSTEM - Matrix IPH
Matrix IPH Standard Details
P.S.P.
PSP-MIPH-P08
sns 10.3.17 1:2 @ A3
Approved
-
Window Jamb Detail
(Plan View)
N
N
LEGEND:
part of system, provided by PSP
provided by others
N
not part of system, can be provided by PSP
22
10
a
20
STANDARD MATRIX-IP VERTICAL &
HORIZONTAL JOINTS ARE 20mm
a PSP Panel thickness - 24mm
LEGEND
b
c
d
e
f
Insulation by others (must be Part B Compliant)
CP board by others - thickness established by project specification
SFS by others - depth established by project specification
Internal finishes by others
Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)
and 50mm (open joints)
Optional colour matched cover trim
Stainless steel fixing (TBC)
8
Insulation by others
Cement particle board by others
Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max
5
6
4
1
2
3
PARTS LIST
7
9
10
11
Internal boards by others
12
Breather membrane by others
13
Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm
14
15
Additional rigid sheet insulation if required by others
16
JT4-4-4.8x19 Stainless steel fixing
JT4-6-5.5x22 A14 Stainless steel fixing
Optional PVC thermal break, 5mm
17
SFS support structure by others
18
19
20
21
22
'Top hat' profile (optional)
Aluminium flashing (Jamb/Head/Coping/Drip)
23
Fire / Smoke Barrier and fittings by others
24
EPDM by others
25
26
Weather seal by others
27
Aluminium carrier bracket, 3mm thick
Internal / External corner flashing
Stainless Steel Fixing Clip
Support Angle
Adjacent Window / Door Profile
Fixing bracket
Corner support angle (factory assembled)
Optional Ventilation profile / insect mesh
Removable panel (replacement procedure ref to PSP-MIPH-S10)
18
DOOR JAMB DETAIL
module length
de
fc
b
Drwg. No.:
Client:
Project:
Title:
Rev Details
Drawn by:Date: Scale:
All Saints Industrial Estate
Shildon
County Durham
DL4 2RD
Tel:
Fax:
Email:
www.pspuk.com
00 44 (0) 1388 770490
00 44 (0) 1388 778068
Unit 11
Status:
Revision:
Date
Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the
specification compliance for each project, PSP will not be held responsible for any project non conformities.
DO NOT SCALE IF IN DOUBT - ASK
PSP SYSTEM - Matrix IPH
Matrix IPH Standard Details
P.S.P.
PSP-MIPH-P09
sns 14.3.17 1:2 @ A3
Approved
-
Door Jamb Detail
(Plan View)
N
N
LEGEND:
part of system, provided by PSP
provided by others
N
not part of system, can be provided by PSP
10
a
20
1 2 3 714
9 1011 5
19
813
22
a PSP Panel thickness - 24mm
LEGEND
b
c
d
e
f
Insulation by others (must be Part B Compliant)
CP board by others - thickness established by project specification
SFS by others - depth established by project specification
Internal finishes by others
Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)
and 50mm (open joints)
Optional colour matched cover trim
Stainless steel fixing (TBC)
8
Insulation by others
Cement particle board by others
Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max
5
6
4
1
2
3
PARTS LIST
7
9
10
11
Internal boards by others
12
Breather membrane by others
13
Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm
14
15
Additional rigid sheet insulation if required by others
16
JT4-4-4.8x19 Stainless steel fixing
JT4-6-5.5x22 A14 Stainless steel fixing
Optional PVC thermal break, 5mm
17
SFS support structure by others
18
19
20
21
22
'Top hat' profile (optional)
Aluminium flashing (Jamb/Head/Coping/Drip)
23
Fire / Smoke Barrier and fittings by others
24
EPDM by others
25
26
Weather seal by others
27
Aluminium carrier bracket, 3mm thick
Internal / External corner flashing
Stainless Steel Fixing Clip
Support Angle
Adjacent Window / Door Profile
Fixing bracket
Corner support angle (factory assembled)
Optional Ventilation profile / insect mesh
Removable panel (replacement procedure ref to PSP-MIPH-S10)
17
21
6
STANDARD MATRIX-IP VERTICAL &
HORIZONTAL JOINTS ARE 20mm
18
module length
de
fc
b
CURTAIN WALL JAMB DETAIL
Drwg. No.:
Client:
Project:
Title:
Rev Details
Drawn by:Date: Scale:
All Saints Industrial Estate
Shildon
County Durham
DL4 2RD
Tel:
Fax:
Email:
www.pspuk.com
00 44 (0) 1388 770490
00 44 (0) 1388 778068
Unit 11
Status:
Revision:
Date
Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the
specification compliance for each project, PSP will not be held responsible for any project non conformities.
DO NOT SCALE IF IN DOUBT - ASK
PSP SYSTEM - Matrix IPH
Matrix IPH Standard Details
P.S.P.
PSP-MIPH-P10
sns 15.3.17 1:2 @ A3
Approved
-
Curtain Walling Jamb Detail
(Plan View)
N
N
LEGEND:
part of system, provided by PSP
provided by others
N
not part of system, can be provided by PSP
1510
a
1 2 3 714
9 1011 5
19
813
22
17
6
a PSP Panel thickness - 24mm
LEGEND
b
c
d
e
f
Insulation by others (must be Part B Compliant)
CP board by others - thickness established by project specification
SFS by others - depth established by project specification
Internal finishes by others
Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)
and 50mm (open joints)
Optional colour matched cover trim
Stainless steel fixing (TBC)
8
Insulation by others
Cement particle board by others
Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max
5
6
4
1
2
3
PARTS LIST
7
9
10
11
Internal boards by others
12
Breather membrane by others
13
Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm
14
15
Additional rigid sheet insulation if required by others
16
JT4-4-4.8x19 Stainless steel fixing
JT4-6-5.5x22 A14 Stainless steel fixing
Optional PVC thermal break, 5mm
17
SFS support structure by others
18
19
20
21
22
'Top hat' profile (optional)
Aluminium flashing (Jamb/Head/Coping/Drip)
23
Fire / Smoke Barrier and fittings by others
24
EPDM by others
25
26
Weather seal by others
27
Aluminium carrier bracket, 3mm thick
Internal / External corner flashing
Stainless Steel Fixing Clip
Support Angle
Adjacent Window / Door Profile
Fixing bracket
Corner support angle (factory assembled)
Optional Ventilation profile / insect mesh
Removable panel (replacement procedure ref to PSP-MIPH-S10)
20
23
STANDARD MATRIX-IP VERTICAL &
HORIZONTAL JOINTS ARE 20mm
18
Horizontal Panel Joint Detail
(Sectional View)
HORIZONTAL PANEL JOINT DETAIL
5
2
24
d e fcba
3
14
7
9
10
11
13
12
1
6
Drwg. No.:
Client:
Project:
Title:
Rev Details
Drawn by:Date: Scale:
All Saints Industrial Estate
Shildon
County Durham
DL4 2RD
Tel:
Fax:
Email:
www.pspuk.com
00 44 (0) 1388 770490
00 44 (0) 1388 778068
Unit 11
Status:
Revision:
Date
Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the
specification compliance for each project, PSP will not be held responsible for any project non conformities.
DO NOT SCALE IF IN DOUBT - ASK
PSP SYSTEM - Matrix IPH
Matrix IPH Standard Details
P.S.P.
PSP-MIPH-S01
sns 15.3.17 1:2 @ A3
Approved
-
N
N
LEGEND:
part of system, provided by PSP
provided by others
N
not part of system, can be provided by PSP
8
20
module height
20
module height
PVC temporary set out packer
to be sued to set joints
20
panel face
module height
20
PVC temporary set out packer
to be sued to set joints
Fixing position if
over 1800mm
Fixing position if
under 1800mm
LAY
a PSP Panel thickness - 24mm
LEGEND
b
c
d
e
f
Insulation by others (must be Part B Compliant)
CP board by others - thickness established by project specification
SFS by others - depth established by project specification
Internal finishes by others
Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)
and 50mm (open joints)
Optional colour matched cover trim
Stainless steel fixing (TBC)
8
Insulation by others
Cement particle board by others
Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max
5
6
4
1
2
3
PARTS LIST
7
9
10
11
Internal boards by others
12
Breather membrane by others
13
Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm
14
15
Additional rigid sheet insulation if required by others
16
JT4-4-4.8x19 Stainless steel fixing
JT4-6-5.5x22 A14 Stainless steel fixing
Optional PVC thermal break, 5mm
17
SFS support structure by others
18
19
20
21
22
'Top hat' profile (optional)
Aluminium flashing (Jamb/Head/Coping/Drip)
23
Fire / Smoke Barrier and fittings by others
24
EPDM by others
25
26
Weather seal by others
27
Aluminium carrier bracket, 3mm thick
Internal / External corner flashing
Stainless Steel Fixing Clip
Support Angle
Adjacent Window / Door Profile
Fixing bracket
Corner support angle (factory assembled)
Optional Ventilation profile / insect mesh
Removable panel (replacement procedure ref to PSP-MIPH-S10)
STANDARD MATRIX-IP VERTICAL &
HORIZONTAL JOINTS ARE 20mm
57,4
51
15
BASE DRIP DETAIL
d e fcb
6
2
Base Drip Detail
(Sectional View)
Drwg. No.:
Client:
Project:
Title:
Rev Details
Drawn by:Date: Scale:
All Saints Industrial Estate
Shildon
County Durham
DL4 2RD
Tel:
Fax:
Email:
www.pspuk.com
00 44 (0) 1388 770490
00 44 (0) 1388 778068
Unit 11
Status:
Revision:
Date
Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the
specification compliance for each project, PSP will not be held responsible for any project non conformities.
DO NOT SCALE IF IN DOUBT - ASK
PSP SYSTEM - Matrix IPH
Matrix IPH Standard Details
P.S.P.
PSP-MIPH-S02
sns 15.3.17 1:2 @ A3
Approved
-
N
N
LEGEND:
part of system, provided by PSP
provided by others
N
not part of system, can be provided by PSP
20
1
a
3
7
24
Fixing position if
over 1800mm
LAY
17
26
a PSP Panel thickness - 24mm
LEGEND
b
c
d
e
f
Insulation by others (must be Part B Compliant)
CP board by others - thickness established by project specification
SFS by others - depth established by project specification
Internal finishes by others
Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)
and 50mm (open joints)
Optional colour matched cover trim
Stainless steel fixing (TBC)
8
Insulation by others
Cement particle board by others
Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max
5
6
4
1
2
3
PARTS LIST
7
9
10
11
Internal boards by others
12
Breather membrane by others
13
Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm
14
15
Additional rigid sheet insulation if required by others
16
JT4-4-4.8x19 Stainless steel fixing
JT4-6-5.5x22 A14 Stainless steel fixing
Optional PVC thermal break, 5mm
17
SFS support structure by others
18
19
20
21
22
'Top hat' profile (optional)
Aluminium flashing (Jamb/Head/Coping/Drip)
23
Fire / Smoke Barrier and fittings by others
24
EPDM by others
25
26
Weather seal by others
27
Aluminium carrier bracket, 3mm thick
Internal / External corner flashing
Stainless Steel Fixing Clip
Support Angle
Adjacent Window / Door Profile
Fixing bracket
Corner support angle (factory assembled)
Optional Ventilation profile / insect mesh
Removable panel (replacement procedure ref to PSP-MIPH-S10)
STANDARD MATRIX-IP VERTICAL &
HORIZONTAL JOINTS ARE 20mm
5
2
14
9
10
11
13
12
8
module height
20
panel face
module height
40
51
COPING FLASHING DETAIL
5
1
7
10
11
13
12
d ecb
2
14
6
17
16
Coping Flashing Detail
(Sectional View)
Drwg. No.:
Client:
Project:
Title:
Rev Details
Drawn by:Date: Scale:
All Saints Industrial Estate
Shildon
County Durham
DL4 2RD
Tel:
Fax:
Email:
www.pspuk.com
00 44 (0) 1388 770490
00 44 (0) 1388 778068
Unit 11
Status:
Revision:
Date
Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the
specification compliance for each project, PSP will not be held responsible for any project non conformities.
DO NOT SCALE IF IN DOUBT - ASK
PSP SYSTEM - Matrix IPH
Matrix IPH Standard Details
P.S.P.
PSP-MIPH-S03
sns 15.3.17 1:2 @ A3
Approved
-
N
N
LEGEND:
part of system, provided by PSP
provided by others
N
not part of system, can be provided by PSP
8
Fixings to secure coping to be determined
on an individual project basis.
3
a
Fixing position if
over 1800mm
a PSP Panel thickness - 24mm
LEGEND
b
c
d
e
f
Insulation by others (must be Part B Compliant)
CP board by others - thickness established by project specification
SFS by others - depth established by project specification
Internal finishes by others
Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)
and 50mm (open joints)
Optional colour matched cover trim
Stainless steel fixing (TBC)
8
Insulation by others
Cement particle board by others
Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max
5
6
4
1
2
3
PARTS LIST
7
9
10
11
Internal boards by others
12
Breather membrane by others
13
Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm
14
15
Additional rigid sheet insulation if required by others
16
JT4-4-4.8x19 Stainless steel fixing
JT4-6-5.5x22 A14 Stainless steel fixing
Optional PVC thermal break, 5mm
17
SFS support structure by others
18
19
20
21
22
'Top hat' profile (optional)
Aluminium flashing (Jamb/Head/Coping/Drip)
23
Fire / Smoke Barrier and fittings by others
24
EPDM by others
25
26
Weather seal by others
27
Aluminium carrier bracket, 3mm thick
Internal / External corner flashing
Stainless Steel Fixing Clip
Support Angle
Adjacent Window / Door Profile
Fixing bracket
Corner support angle (factory assembled)
Optional Ventilation profile / insect mesh
Removable panel (replacement procedure ref to PSP-MIPH-S10)
STANDARD MATRIX-IP VERTICAL &
HORIZONTAL JOINTS ARE 20mm
WINDOW HEAD DETAIL
dcb e f
17 21
19
8
5
1
3
10
11
14
Drainage slots
6
2
13
7
22
Window Head Detail
(Sectional View)
Drwg. No.:
Client:
Project:
Title:
Rev Details
Drawn by:Date: Scale:
All Saints Industrial Estate
Shildon
County Durham
DL4 2RD
Tel:
Fax:
Email:
www.pspuk.com
00 44 (0) 1388 770490
00 44 (0) 1388 778068
Unit 11
Status:
Revision:
Date
Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the
specification compliance for each project, PSP will not be held responsible for any project non conformities.
DO NOT SCALE IF IN DOUBT - ASK
PSP SYSTEM - Matrix IPH
Matrix IPH Standard Details
P.S.P.
PSP-MIPH-S04
sns 16.3.17 1:2 @ A3
Approved
-
N
N
LEGEND:
part of system, provided by PSP
provided by others
N
not part of system, can be provided by PSP
a
Drainage slots
a PSP Panel thickness - 24mm
LEGEND
b
c
d
e
f
Insulation by others (must be Part B Compliant)
CP board by others - thickness established by project specification
SFS by others - depth established by project specification
Internal finishes by others
Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)
and 50mm (open joints)
Optional colour matched cover trim
Stainless steel fixing (TBC)
8
Insulation by others
Cement particle board by others
Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max
5
6
4
1
2
3
PARTS LIST
7
9
10
11
Internal boards by others
12
Breather membrane by others
13
Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm
14
15
Additional rigid sheet insulation if required by others
16
JT4-4-4.8x19 Stainless steel fixing
JT4-6-5.5x22 A14 Stainless steel fixing
Optional PVC thermal break, 5mm
17
SFS support structure by others
18
19
20
21
22
'Top hat' profile (optional)
Aluminium flashing (Jamb/Head/Coping/Drip)
23
Fire / Smoke Barrier and fittings by others
24
EPDM by others
25
26
Weather seal by others
27
Aluminium carrier bracket, 3mm thick
Internal / External corner flashing
Stainless Steel Fixing Clip
Support Angle
Adjacent Window / Door Profile
Fixing bracket
Corner support angle (factory assembled)
Optional Ventilation profile / insect mesh
Removable panel (replacement procedure ref to PSP-MIPH-S10)
STANDARD MATRIX-IP VERTICAL &
HORIZONTAL JOINTS ARE 20mm
LAY
25
51
18
WINDOW CILL DETAIL
19
8
5
1
3
10
13
9
12
d ecb
2
14
6
f
17
22
Window Base Detail 2
(Sectional View)
Drwg. No.:
Client:
Project:
Title:
Rev Details
Drawn by:Date: Scale:
All Saints Industrial Estate
Shildon
County Durham
DL4 2RD
Tel:
Fax:
Email:
www.pspuk.com
00 44 (0) 1388 770490
00 44 (0) 1388 778068
Unit 11
Status:
Revision:
Date
Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the
specification compliance for each project, PSP will not be held responsible for any project non conformities.
DO NOT SCALE IF IN DOUBT - ASK
PSP SYSTEM - Matrix IPH
Matrix IPH Standard Details
P.S.P.
PSP-MIPH-S05
sns 16.3.17 1:2 @ A3
Approved
-
N
N
LEGEND:
part of system, provided by PSP
provided by others
N
not part of system, can be provided by PSP
21
10
module height
10
a
LAY
a PSP Panel thickness - 24mm
LEGEND
b
c
d
e
f
Insulation by others (must be Part B Compliant)
CP board by others - thickness established by project specification
SFS by others - depth established by project specification
Internal finishes by others
Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)
and 50mm (open joints)
Optional colour matched cover trim
Stainless steel fixing (TBC)
8
Insulation by others
Cement particle board by others
Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max
5
6
4
1
2
3
PARTS LIST
7
9
10
11
Internal boards by others
12
Breather membrane by others
13
Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm
14
15
Additional rigid sheet insulation if required by others
16
JT4-4-4.8x19 Stainless steel fixing
JT4-6-5.5x22 A14 Stainless steel fixing
Optional PVC thermal break, 5mm
17
SFS support structure by others
18
19
20
21
22
'Top hat' profile (optional)
Aluminium flashing (Jamb/Head/Coping/Drip)
23
Fire / Smoke Barrier and fittings by others
24
EPDM by others
25
26
Weather seal by others
27
Aluminium carrier bracket, 3mm thick
Internal / External corner flashing
Stainless Steel Fixing Clip
Support Angle
Adjacent Window / Door Profile
Fixing bracket
Corner support angle (factory assembled)
Optional Ventilation profile / insect mesh
Removable panel (replacement procedure ref to PSP-MIPH-S10)
STANDARD MATRIX-IP VERTICAL &
HORIZONTAL JOINTS ARE 20mm
18
DOOR HEAD DETAIL
module height
dcb e f
17 21
8
5
1
3
10
11
14
Drainage slots
6
2
13
22
Door Head Detail 1
(Sectional View)
Drwg. No.:
Client:
Project:
Title:
Rev Details
Drawn by:Date: Scale:
All Saints Industrial Estate
Shildon
County Durham
DL4 2RD
Tel:
Fax:
Email:
www.pspuk.com
00 44 (0) 1388 770490
00 44 (0) 1388 778068
Unit 11
Status:
Revision:
Date
Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the
specification compliance for each project, PSP will not be held responsible for any project non conformities.
DO NOT SCALE IF IN DOUBT - ASK
PSP SYSTEM - Matrix IPH
Matrix IPH Standard Details
P.S.P.
PSP-MIPH-S06
sns 16.3.17 1:2 @ A3
Approved
-
N
N
LEGEND:
part of system, provided by PSP
provided by others
N
not part of system, can be provided by PSP
a
Drainage slots
51
a PSP Panel thickness - 24mm
LEGEND
b
c
d
e
f
Insulation by others (must be Part B Compliant)
CP board by others - thickness established by project specification
SFS by others - depth established by project specification
Internal finishes by others
Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)
and 50mm (open joints)
Optional colour matched cover trim
Stainless steel fixing (TBC)
8
Insulation by others
Cement particle board by others
Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max
5
6
4
1
2
3
PARTS LIST
7
9
10
11
Internal boards by others
12
Breather membrane by others
13
Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm
14
15
Additional rigid sheet insulation if required by others
16
JT4-4-4.8x19 Stainless steel fixing
JT4-6-5.5x22 A14 Stainless steel fixing
Optional PVC thermal break, 5mm
17
SFS support structure by others
18
19
20
21
22
'Top hat' profile (optional)
Aluminium flashing (Jamb/Head/Coping/Drip)
23
Fire / Smoke Barrier and fittings by others
24
EPDM by others
25
26
Weather seal by others
27
Aluminium carrier bracket, 3mm thick
Internal / External corner flashing
Stainless Steel Fixing Clip
Support Angle
Adjacent Window / Door Profile
Fixing bracket
Corner support angle (factory assembled)
Optional Ventilation profile / insect mesh
Removable panel (replacement procedure ref to PSP-MIPH-S10)
STANDARD MATRIX-IP VERTICAL &
HORIZONTAL JOINTS ARE 20mm
19
18
17 25
8
5
dcb
14
10
e f
Drainage slots
CURTAIN WALL HEAD DETAIL
Fixings subject to
Structural Analysis
19
5
16
4
13
22
Curtain Walling Head Detail
(Sectional View)
Drwg. No.:
Client:
Project:
Title:
Rev Details
Drawn by:Date: Scale:
All Saints Industrial Estate
Shildon
County Durham
DL4 2RD
Tel:
Fax:
Email:
www.pspuk.com
00 44 (0) 1388 770490
00 44 (0) 1388 778068
Unit 11
Status:
Revision:
Date
Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the
specification compliance for each project, PSP will not be held responsible for any project non conformities.
DO NOT SCALE IF IN DOUBT - ASK
PSP SYSTEM - Matrix IPH
Matrix IPH Standard Details
P.S.P.
PSP-MIPH-S07
sns 16.3.17 1:2 @ A3
Approved
-
N
N
LEGEND:
part of system, provided by PSP
provided by others
N
not part of system, can be provided by PSP
module height
1
3
14
6
2
a
a PSP Panel thickness - 24mm
LEGEND
b
c
d
e
f
Insulation by others (must be Part B Compliant)
CP board by others - thickness established by project specification
SFS by others - depth established by project specification
Internal finishes by others
Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)
and 50mm (open joints)
Optional colour matched cover trim
Stainless steel fixing (TBC)
8
Insulation by others
Cement particle board by others
Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max
5
6
4
1
2
3
PARTS LIST
7
9
10
11
Internal boards by others
12
Breather membrane by others
13
Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm
14
15
Additional rigid sheet insulation if required by others
16
JT4-4-4.8x19 Stainless steel fixing
JT4-6-5.5x22 A14 Stainless steel fixing
Optional PVC thermal break, 5mm
17
SFS support structure by others
18
19
20
21
22
'Top hat' profile (optional)
Aluminium flashing (Jamb/Head/Coping/Drip)
23
Fire / Smoke Barrier and fittings by others
24
EPDM by others
25
26
Weather seal by others
27
Aluminium carrier bracket, 3mm thick
Internal / External corner flashing
Stainless Steel Fixing Clip
Support Angle
Adjacent Window / Door Profile
Fixing bracket
Corner support angle (factory assembled)
Optional Ventilation profile / insect mesh
Removable panel (replacement procedure ref to PSP-MIPH-S10)
STANDARD MATRIX-IP VERTICAL &
HORIZONTAL JOINTS ARE 20mm
51
18
FIRE BARRIERS DETAIL
Fire Barrier Detail
(Sectional View)
Drwg. No.:
Client:
Project:
Title:
Rev Details
Drawn by:Date: Scale:
All Saints Industrial Estate
Shildon
County Durham
DL4 2RD
Tel:
Fax:
Email:
www.pspuk.com
00 44 (0) 1388 770490
00 44 (0) 1388 778068
Unit 11
Status:
Revision:
Date
Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the
specification compliance for each project, PSP will not be held responsible for any project non conformities.
DO NOT SCALE IF IN DOUBT - ASK
PSP SYSTEM - Matrix IPH
Matrix IPH Standard Details
P.S.P.
PSP-MIPH-S08
sns 16.3.17 1:2 @ A3
Approved
-
N
N
LEGEND:
part of system, provided by PSP
provided by others
N
not part of system, can be provided by PSP
12
10
9
11
18
d e fcb
13
1
14
Intumescent strip
expansion refer to
manufacturer
a
a PSP Panel thickness - 24mm
LEGEND
b
c
d
e
f
Insulation by others (must be Part B Compliant)
CP board by others - thickness established by project specification
SFS by others - depth established by project specification
Internal finishes by others
Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)
and 50mm (open joints)
Optional colour matched cover trim
Stainless steel fixing (TBC)
8
Insulation by others
Cement particle board by others
Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max
5
6
4
1
2
3
PARTS LIST
7
9
10
11
Internal boards by others
12
Breather membrane by others
13
Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm
14
15
Additional rigid sheet insulation if required by others
16
JT4-4-4.8x19 Stainless steel fixing
JT4-6-5.5x22 A14 Stainless steel fixing
Optional PVC thermal break, 5mm
17
SFS support structure by others
18
19
20
21
22
'Top hat' profile (optional)
Aluminium flashing (Jamb/Head/Coping/Drip)
23
Fire / Smoke Barrier and fittings by others
24
EPDM by others
25
26
Weather seal by others
27
Aluminium carrier bracket, 3mm thick
Internal / External corner flashing
Stainless Steel Fixing Clip
Support Angle
Adjacent Window / Door Profile
Fixing bracket
Corner support angle (factory assembled)
Optional Ventilation profile / insect mesh
Removable panel (replacement procedure ref to PSP-MIPH-S10)
STANDARD MATRIX-IP VERTICAL &
HORIZONTAL JOINTS ARE 20mm
8
5
2
2
7
d e fcba
3
9
10
11
13
12
REMOVABLE PANEL HORIZONTAL JOINT DETAIL
Replacement procedure ref to PSP-MIPH-S10
Removal Panel Joint Detail
(Sectional View)
Drwg. No.:
Client:
Project:
Title:
Rev Details
Drawn by:Date: Scale:
All Saints Industrial Estate
Shildon
County Durham
DL4 2RD
Tel:
Fax:
Email:
www.pspuk.com
00 44 (0) 1388 770490
00 44 (0) 1388 778068
Unit 11
Status:
Revision:
Date
Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the
specification compliance for each project, PSP will not be held responsible for any project non conformities.
DO NOT SCALE IF IN DOUBT - ASK
PSP SYSTEM - Matrix IPH
Matrix IPH Standard Details
P.S.P.
PSP-MIPH-S09
sns 16.3.17 1:2 @ A3
Approved
-
N
N
LEGEND:
part of system, provided by PSP
provided by others
N
not part of system, can be provided by PSP
14
1
module height
20
module height
20
panel face
module height
LAY
a PSP Panel thickness - 24mm
LEGEND
b
c
d
e
f
Insulation by others (must be Part B Compliant)
CP board by others - thickness established by project specification
SFS by others - depth established by project specification
Internal finishes by others
Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)
and 50mm (open joints)
Optional colour matched cover trim
Stainless steel fixing (TBC)
8
Insulation by others
Cement particle board by others
Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max
5
6
4
1
2
3
PARTS LIST
7
9
10
11
Internal boards by others
12
Breather membrane by others
13
Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm
14
15
Additional rigid sheet insulation if required by others
16
JT4-4-4.8x19 Stainless steel fixing
JT4-6-5.5x22 A14 Stainless steel fixing
Optional PVC thermal break, 5mm
17
SFS support structure by others
18
19
20
21
22
'Top hat' profile (optional)
Aluminium flashing (Jamb/Head/Coping/Drip)
23
Fire / Smoke Barrier and fittings by others
24
EPDM by others
25
26
Weather seal by others
27
Aluminium carrier bracket, 3mm thick
Internal / External corner flashing
Stainless Steel Fixing Clip
Support Angle
Adjacent Window / Door Profile
Fixing bracket
Corner support angle (factory assembled)
Optional Ventilation profile / insect mesh
Removable panel (replacement procedure ref to PSP-MIPH-S10)
STANDARD MATRIX-IP VERTICAL &
HORIZONTAL JOINTS ARE 20mm
57,4
51
Drwg. No.:
Client:
Project:
Title:
Rev Details
Drawn by:Date: Scale:
All Saints Industrial Estate
Shildon
County Durham
DL4 2RD
Tel:
Fax:
Email:
www.pspuk.com
00 44 (0) 1388 770490
00 44 (0) 1388 778068
Unit 11
Status:
Revision:
Date
Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the
specification compliance for each project, PSP will not be held responsible for any project non conformities.
DO NOT SCALE IF IN DOUBT - ASK
Replacement Panel Procedure
Matrix IPH Standard Details
P.S.P.
PSP-MIPH-S10
sns 16.3.17 1:2 @ A3
Approved
Details
1. PANEL TO BE REMOVED TO BE CUT ALONG JOINT
2. UNSCREW/CHISEL OFF EXISTING FIXING HEAD FROM BELOW
3. INSERT NEW PANEL
4. FIX VIA JOINT USING LOW PROFILE HEADED FIXING
PROCEDURE
(THIS DRAWING SHOWS HORIZONTALLY LAID PANELS.
FOR VERTICALLY LAID PANELS ROTATE 90°)
CUT
UNSCREW/CHISEL OFF
FIXING
INSERT
NEW PANEL
FIX
STEP 1 STEP 2 STEP 3 STEP 4
PSP SYSTEM - Matrix IPH
MOVEMENT
SLIDING
BRACKET
FIXED
POINT
BRACKET
FLOOR SLAB
BY OTHERS
WALL
STRUCTURE
BY OTHERS
WALL
STRUCTURE
BY OTHERS
VERTICAL
T-RAIL
AS REQ
'D
LOWER PANEL
CAN BE MADE
REMOVABLE OR
RETROFITTED IF
REQUIRED
FEMALE EDGE
OF LOWER PANEL
AS STANDARD
PANEL
MOVEMENT JOINT DETAIL
Drwg. No.:
Client:
Project:
Title:
Rev Details
Drawn by:Date: Scale:
All Saints Industrial Estate
Shildon
County Durham
DL4 2RD
Tel:
Fax:
Email:
www.pspuk.com
00 44 (0) 1388 770490
00 44 (0) 1388 778068
Unit 11
Status:
Revision:
Date
Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the
specification compliance for each project, PSP will not be held responsible for any project non conformities.
DO NOT SCALE IF IN DOUBT - ASK
Typical Movement Joint
Details
Matrix IPH Standard Details
P.S.P.
PSP-MIPH-S11
sns 20.3.17 1:2 @ A3
Approved
module height
20
module height
20
panel face
LAY
8
1
2
3
12
25
7
6
Optional colour matched cover trim
Stainless steel fixing (TBC)
8
Insulation by others
Cement particle board by others
Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max
5
6
4
1
2
3
PARTS LIST
7
9
10
11
Internal boards by others
12
Breather membrane by others
13
Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm
14
15
Additional rigid sheet insulation if required by others
16
JT4-4-4.8x19 Stainless steel fixing
JT4-6-5.5x22 A14 Stainless steel fixing
Optional PVC thermal break, 5mm
17
SFS support structure by others
18
19
20
21
22
'Top hat' profile (optional)
Aluminium flashing (Jamb/Head/Coping/Drip)
23
Fire / Smoke Barrier and fittings by others
24
EPDM by others
25
26
Weather seal by others
27
Aluminium carrier bracket, 3mm thick
Internal / External corner flashing
Stainless Steel Fixing Clip
Support Angle
Adjacent Window / Door Profile
Fixing bracket
Corner support angle (factory assembled)
Optional Ventilation profile / insect mesh
Removable panel (replacement procedure ref to PSP-MIPH-S10)
24
PSP SYSTEM - Matrix IPH
5
9
10
11
13
N
N
LEGEND:
part of system, provided by PSP
provided by others
N
not part of system, can be provided by PSP
18