Report No. 068L169-RF-CE-P02V01
Page: 1 of 72 Version:1.0
Test Report
Product Name MEGA BOOK
Model No. MS-1414, S430, S430X
Transmitter Module. MSI / MS-6877
Applicant MICRO-STAR INT'L Co., LTD.
Address No. 69, Li-De St., Jung-He City, Taipei Hsien, Taiwan, R.O.C.
Date of Receipt Aug. 22, 2006
Issued Date Oct. 12, 2006
Report No. 068L169-RF-CE-P02V01
The Test Results relate only to the samples tested. The test report shall not be reproduced except in full without the written approval of QuieTek Corporation.
Report No. 068L169-RF-CE-P02V01
Page: 2 of 72 Version:1.0
Test Report Cert i f icat ion Issued Date: Oct. 12, 2006 Report No.: 068L169-RF-CE-P02V01
Product Name MEGA BOOK
Applicant MICRO-STAR INT'L Co., LTD.
Address No. 69, Li-De St., Jung-He City, Taipei Hsien, Taiwan, R.O.C.
Manufacturer MICRO-STAR INT'L Co., LTD.
Model No. MS-1414, S430, S430X
Rated Voltage AC 230V/50Hz
EUT Working Voltage AC 230V/50Hz
Trade Name MSI
Applicable Standard ETSI EN 301 489-17:V1.2.1 (2002-08)
ETSI EN 301489-1: V1.5.1 (2004-11)
Test Result Complied
The test results relate only to the samples tested. The test report shall not be reproduced except in full without the written approval of QuieTek Corporation.
Documented By :
( A n i t a C h o u )
Tested By :
( T i m S u n g )
Approved By :
( G e o r g e C h e n )
Accredited by DNV, Nemko and NIST (NVLAP)
0914
Report No. 068L169-RF-CE-P02V01
Page: 3 of 72 Version:1.0
TABLE OF CONTENTS Description Page 1. GENERAL INFORMATION...............................................................................................5 1.1. EUT Description .....................................................................................................................5 1.2. Tested System Details .............................................................................................................7 1.3. Configuration of Test System..................................................................................................8 1.4. EUT Exercise Software...........................................................................................................8 1.5. Test Facility.............................................................................................................................9 2. Conducted Emission ...........................................................................................................10 2.1. Test Equipmen.......................................................................................................................10 2.2. Test Setup..............................................................................................................................10 2.3. Limits ....................................................................................................................................11 2.4. Test Procedure.......................................................................................................................12 2.5. Test Specification..................................................................................................................12 2.6. Uncertainty............................................................................................................................12 2.7. Test Result.............................................................................................................................12 3. Radiated Emission ..............................................................................................................13 3.1. Test Equipment .....................................................................................................................13 3.2. Test Setup..............................................................................................................................13 3.3. Limits ....................................................................................................................................14 3.4. Test Procedure.......................................................................................................................14 3.5. Test Specification..................................................................................................................14 3.6. Uncertainty............................................................................................................................14 3.7. Test Result.............................................................................................................................14 4. Power Harmonics, Voltage Fluctuation and Flicker........................................................15 4.1. Test Equipment .....................................................................................................................15 4.2. Test Setup..............................................................................................................................15 4.3. Limits ....................................................................................................................................15 4.4. Test Procedure.......................................................................................................................16 4.5. Test Specification..................................................................................................................16 4.6. Uncertainty............................................................................................................................16 4.7. Test Result.............................................................................................................................16 5. Electrostatic Discharge (ESD)............................................................................................17 5.1. Test Equipment .....................................................................................................................17 5.2. Test Setup..............................................................................................................................17 5.3. Test Level ..............................................................................................................................17 5.4. Test Procedure.......................................................................................................................18 5.5. Test Specification..................................................................................................................18 5.6. Uncertainty............................................................................................................................18 5.7. Test Result.............................................................................................................................18 6. Radiated Susceptibility (RS) ..............................................................................................19 6.1. Test Equipment .....................................................................................................................19 6.2. Test Setup..............................................................................................................................19 6.3. Test Level ..............................................................................................................................19 6.4. Test Procedure.......................................................................................................................20 6.5. Test Specification..................................................................................................................20 6.6. Uncertainty............................................................................................................................20 6.7. Test Result.............................................................................................................................20 7. Electrical Fast Transient/Burst (EFT/B)...........................................................................21 7.1. Test Equipment .....................................................................................................................21
Report No. 068L169-RF-CE-P02V01
Page: 4 of 72 Version:1.0
7.2. Test Setup..............................................................................................................................21 7.3. Test Level ..............................................................................................................................22 7.4. Test Procedure.......................................................................................................................22 7.5. Test Specification..................................................................................................................22 7.6. Uncertainty............................................................................................................................22 7.7. Test Result.............................................................................................................................22 8. Surge.....................................................................................................................................23 8.1. Test Equipment .....................................................................................................................23 8.2. Test Setup..............................................................................................................................23 8.3. Test Level ..............................................................................................................................23 8.4. Test Procedure.......................................................................................................................24 8.5. Test Specification..................................................................................................................24 8.6. Uncertainty............................................................................................................................24 8.7. Test Result.............................................................................................................................24 9. Conducted Susceptibility (CS) ...........................................................................................25 9.1. Test Equipment .....................................................................................................................25 9.2. Test Setup..............................................................................................................................25 9.3. Test Level ..............................................................................................................................25 9.4. Test Procedure.......................................................................................................................26 9.5. Test Specification..................................................................................................................26 9.6. Uncertainty............................................................................................................................26 9.7. Test Result.............................................................................................................................26 10. Voltage Dips and Interruption ...........................................................................................27 10.1. Test Equipment .....................................................................................................................27 10.2. Test Setup..............................................................................................................................27 10.3. Test Level ..............................................................................................................................27 10.4. Test Procedure.......................................................................................................................28 10.5. Test Specification..................................................................................................................28 10.6. Uncertainty............................................................................................................................28 10.7. Test Result.............................................................................................................................28 11. EMC Reduction Method During Compliance Testing ....................................................29 12. Test Result............................................................................................................................30 12.1. Test Data of Conducted Emission.........................................................................................31 12.2. Test Data of Radiated Emission ............................................................................................40 12.3. Test Data of Power Harmonics, Voltage Flucturation and Flicker........................................43 12.4. Test Data of Electrostatic Discharge .....................................................................................52 12.5. Test Data of Radiated Susceptibility.....................................................................................55 12.6. Test Data of Electrical Fast Transient ...................................................................................58 12.7. Test Data of Surge.................................................................................................................61 12.8. Test Data of Conducted Susceptibility..................................................................................64 12.9. Test Data of Voltage Dips and Interruption...........................................................................67 Attachment 1: EUT Test Photographs Attachment 2: EUT Detailed Photographs Reference : Laboratory of License
Report No. 068L169-RF-CE-P02V01
Page: 5 of 72 Version:1.0
1. GENERAL INFORMATION
1.1. EUT Description
Product Name MEGA BOOK
Trade Name MSI
Model No. MS-1414, S430, S430X
EUT Working Voltage AC 230V/50Hz
Frequency Range 802.11b/g:2400-2483.5MHz
Number of Channels 802.11b/g: 13CH
Data Speed DSSS: 1, 2, 5.5, 11Mbps
OFDM: 6, 9, 12, 18, 24, 36, 48, 54Mbps
Channel separation 802.11b/g: 5MHz
Type of Modulation DSSS/OFDM
Channel Control Auto
Antenna Gain Refer to the table “Antenna List”
Antenna type Connector
Power Adapter (1) MFR: LI SHIN, M/N: LSE0202C1990
Power Adapter (2) MFR: LITEON, M/N: PA-1900-04RM
Power Adapter (3) MFR: LI SHIN, M/N: 0335A1965
Antenna List
No. Manufacturer Part No. Peak Gain 1 SmartAnt S79-1800180-SB1 2.31dBi for 2.4 GHz
Report No. 068L169-RF-CE-P02V01
Page: 6 of 72 Version:1.0
Center Frequency of Each Channel:
Channel Frequency Channel Frequency Channel Frequency Channel FrequencyChannel 01: 2412 MHz Channel 02: 2417 MHz Channel 03: 2422 MHz Channel 04: 2427 MHz Channel 05: 2432 MHz Channel 06: 2437 MHz Channel 07: 2442 MHz Channel 08: 2447 MHz Channel 09: 2452 MHz Channel 10: 2457 MHz Channel 11: 2462 MHz Channel 12: 2467 MHz Channel 13: 2472 MHz Note: 1. The EUT has three models for different marketing requirement. 2. QuieTek verified the construction and function in typical operation. All the test modes were carried out with
the EUT in normal operation, which was shown in this test report and defined as:
EMI Mode Mode1: Normal Operation (Adapter 1) Mode2: Normal Operation (Adapter 2) Mode3: Normal Operation (Adapter 3)
EMS Mode Mode1: Normal Operation (Adapter 1) Mode2: Normal Operation (Adapter 2) Mode3: Normal Operation (Adapter 3)
Report No. 068L169-RF-CE-P02V01
Page: 7 of 72 Version:1.0
1.2. Tested System Details
The types for all equipment, plus descriptions of all cables used in the tested system (including inserted cards) are:
Product Manufacturer Model No. Serial No. Power Cord
1 LCD Monitor CMV CT-730D FNC122F57BA1704 Non-Shielded, 1.8m
2 Walkman AIWA HS-TA164 N/A N/A
3 Microphone &
Earphone
PCHOME N/A N/A Non-Shielded, 2m
4 USB 2.0 HDD AACOM F12-UF N/A Power by PC
5 USB 2.0 HDD AACOM F12-UF N/A Power by PC
6 USB 2.0 HDD AACOM F12-UF N/A Power by PC
7 USB 2.0 HDD AACOM F12-UF N/A Power by PC
8 SATA HDD Onnto ST-M10 500127-E33-0007 Non-Shielded, 1.8m,
with one ferrite core bonded.
9 Exchange Network Sun Moon Star PX-4 95170087 Non-Shielded, 1.8m
10 Notebook PC DELL PPT N/A Non-Shielded, 0.8m
Signal Cable Type Signal cable Description
A D-SUB Cable Shielded, 1.8m, with two ferrite cores bonded
B Audio Cable Non-Shielded, 1.6m
C Earphone & Microphone Cable Non-Shielded, 1.8m
D USB Cable Shielded, 1.5m
E USB Cable Shielded, 1.5m
F USB Cable Shielded, 1.5m
G USB Cable Shielded, 1.5m
H SATA Cable Shielded, 1.2m
I TELECOM Cable Non-Shielded, 7m
J TELECOM Cable Non-Shielded, 7m
K LAN Cable Non-Shielded, 7m
Report No. 068L169-RF-CE-P02V01
Page: 8 of 72 Version:1.0
1.3. Configuration of Test System
1.4. EUT Exercise Software
(1) Setup the EUT and simulators as shown on 1.3. (2) Turn on the power of all equipment. (3) Boot the PC from Hard Disk. (4) PC reads test software from disk
(5) The Notebook PC's and far Notebook PC's monitor will show the transmitting and receiving characteristics when the communication is success.
(6) Wireless LAN function was used to perform the wireless data transmission. (7) Repeat the step 5 and 6.
Report No. 068L169-RF-CE-P02V01
Page: 9 of 72 Version:1.0
1.5. Test Facility
Ambient conditions in the laboratory:
Items Test Item Required (IEC 68-1) Actual
Temperature (°C) 15-35 20-35
Humidity (%RH) 30-60 50-55
Barometric pressure (mbar)
IEC 61000-4-2
860-1060 950-1000
Temperature (°C) 15-35 20-35
Humidity (%RH) 10-75 50-65
Barometric pressure (mbar)
IEC 61000-4-5
860-1060 950-1000
Temperature (°C) 15-35 20-35
Barometric pressure (mbar)
IEC 61000-4-4 IEC 61000-4-11 860-1060 950-1000
Site Description: Accredited by NVLAP NVLAP Lab Code: 200533-0 Accredited by DNV Statement No. : 413-99-LAB11 Accredited by Nemko Certificate No.: ELA 165 Accredited by TUV Rheinland Certificate No.: 10011438-1-2004 Accredited by CNLA Accredited Number: 0914 Site Name: Quietek Corporation Site Address: No. 5-22, Ruei-Shu Valley, Ruei-Ping Tsuen, Lin-Kou Shiang, Taipei, Taiwan, R.O.C. TEL : 886-2-8601-3788 / FAX : 886-2-8601-3789 E-Mail : [email protected]
0914
Report No. 068L169-RF-CE-P02V01
Page: 10 of 72 Version:1.0
2. Conducted Emission
2.1. Test Equipmen
The following test equipment are used during the conducted emission test:
Item Equipment Manufacturer Model No. / Serial No. Last Cal. Remark
1 Test Receiver R & S ESCS 30 / 825442/018 Sep., 2006
2 Artificial Mains Network R & S ENV4200 / 848411/10 Feb., 2006 Peripherals
3 LISN R & S ESH3-Z5 / 825562/002 Feb., 2006 EUT
4 Pulse Limiter R & S ESH3-Z2 / 357.8810.52 Feb., 2006
5 4-wire ISN R & S ENY41 / 837032/001 Feb., 2006
6 Double 2-Wire ISN R & S ENY22 / 835354/008 Feb., 2006
7 No.1 Shielded Room
Note: All equipments are calibrated every one year.
2.2. Test Setup
Peripheral
80cm
AMN for EUT
Shielded Room
40cm
( EUT )
≧0.8m
AMN for Peripheral
50 ohm Terminator Test Receiver
Report No. 068L169-RF-CE-P02V01
Page: 11 of 72 Version:1.0
2.3. Limits
(1) Mains terminal
Limits (dBuV)
Limit for conducted emissions of equipment intended to be used in telecommunication centers only
Limit for conducted emissions Frequency
MHz
QP AV QP AV
0.15 - 0.50 79 66 66-56 56-46
0.50-5.0 73 60 56 46
5.0 - 30 73 60 60 50
Remarks: The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz ~ 0.50 MHz.
(2) Telecommunication ports Limits (dBuV)
Limit for conducted emissions from telecommunication ports of
equipment intended for use in telecommunication centers only
Limit for conducted emissions from telecommunication ports Frequency
MHz
QP AV QP AV
0.15 – 0.50 97-87 84-74 84-74 74-64
5.0 – 30 87 74 74 64
Remarks: In the above table, the tighter limit applies at the band edges.
Report No. 068L169-RF-CE-P02V01
Page: 12 of 72 Version:1.0
2.4. Test Procedure
AC Mains: The EUT and simulators are connected to the main power through a line impedance stabilization
network (L.I.S.N.). This provides a 50 ohm /50uH coupling impedance for the measuring equipment. The peripheral devices are also connected to the main power through a LISN that provides a 50ohm /50uH coupling impedance with 50ohm termination. (Please refers to the block diagram of the test setup and photographs.)
Both sides of AC line are checked for maximum conducted interference. In order to find the maximum emission, the relative positions of equipment and all of the interface cables must be changed according to ETSI EN 301489-1: V1.5.1 (2004-11) on conducted measurement. The bandwidth of the field strength meter (R & S Test Receiver ESCS 30) is set at 9kHz.
Telecommunication Port: The mains voltage shall be supplied to the EUT via the LISN when the measurement of
telecommunication port is performed. The common mode disturbances at the telecommunication port shall be connected to the ISN, which is 150ohm impedance. Both alternative cables are tested related to the LCL requested. The measurement range is from 150kHz to 30MHz. The bandwidth of measurement is set to 9kHz. The 60dB LCL ISN is used for cat. 5 cable, 50dB LCL ISN is used for cat. 3 and 80dB LCL is wed for alternative one.
2.5. Test Specification
According to ETSI EN 301489-1: V1.5.1 (2004-11) EN 55022:1998+A1: 2000 +A2: 2003
2.6. Uncertainty
± 2.26 dB
2.7. Test Result
The emission from the EUT was below the specified limits. The worst-case emissions are shown in section 12. The EUT complies the acceptance criterion and passes the test.
Report No. 068L169-RF-CE-P02V01
Page: 13 of 72 Version:1.0
3. Radiated Emission
3.1. Test Equipment
The following test equipment are used during the Radiated emission test:
Test Site Equipment Manufacturer Model No./Serial No. Last Cal. Test Receiver R & S ESVS 10 / 834468/003 July, 2006
Spectrum Analyzer Advantest R3162/ 00803480 May, 2006
Pre-Amplifier Advantest BB525C/ 3307A01812 May, 2006
Site # 1
Bilog Antenna SCHAFFNER CBL6112B / 2697 Nov., 2005
Test Receiver R & S ESCS 30 / 836858 / 022 Nov., 2005
Spectrum Analyzer Advantest R3162 / 100803466 May, 2006
Pre-Amplifier Advantest BB525C/3307A01814 May, 2006
Bilog Antenna SCHAFFNER CBL6112B / 2705 Oct., 2006
Horn Antenna ETS 3115 / 0005-6160 July, 2006
Site # 2
Pre-Amplifier QTK QTK-AMP-01/ 0001 July, 2006
Test Receiver R & S ESI 26 / 838786 / 004 May, 2006
Spectrum Analyzer Advantest R3162 / 100803480 May, 2006
Pre-Amplifier QTK QTK-AMP-03 / 0003 May, 2006
Bilog Antenna SCHAFFNER CBL6112B / 2697 May, 2006
Horn Antenna ETS 3115 / 0005-6160 July, 2006
Site # 3
Pre-Amplifier QTK QTK-AMP-01 / 0001 July, 2006 Note: 1. All equipments are calibrated every one year. 2. The test instruments marked by “X” are used to measure the final test results.
3.2. Test Setup
EUT
FRP Dome
Test Receiver
Antenna Mast Dipole or Horn Antenna Antenna height can be moved from 1m to 4m, Antenna and turntable distance 3m
TO ControllerTo Receiver
Fully Soldered Ground Plane
Non-Conducted Table
10m
1m to 4m
80cm
Load
Report No. 068L169-RF-CE-P02V01
Page: 14 of 72 Version:1.0
3.3. Limits
Limits dB(uV/m)
Limit for radiated emissions from ancillary equipment intended for use in telecommunication centers
only, and measured on a stand alone basis
Limit for radiated emissions from ancillary equipment , measured on
a stand alone basis
Frequency
MHz
QP QP
30-230 40 30
230-1000 47 37
3.4. Test Procedure
The EUT and its simulators are placed on a turn table which is 0.8 meter above ground. The turn table can rotate 360 degrees to determine the position of the maximum emission level. The EUT was positioned such that the distance from antenna to the EUT was 10 meters.The antenna can move up and down between 1 meter and 4 meters to find out the maximum emission level. Both horizontal and vertical polarization of the antenna are set on measurement. In order to find the maximum emission, all of the interface cables must be manipulated according to ETSI EN 301489-1: V1.5.1 (2004-11) on radiated measurement. The additional motch filter below 1GHz was used to measure the level of harmonics radiated emission during field dtrength of harmonics measurement. The bandwidth below 1GHz setting on the field strength meter (R&S Test Receiver ESCS 30) is 120 kHz, and 1MHz bandwidth is adpted above 1GHz. The frequency range from 30MHz to 10th harmonics is checked.
3.5. Test Specification
According to ETSI EN 301489-1: V1.5.1 (2004-11) EN 55022:1998+A1: 2002+A2: 2003
3.6. Uncertainty
± 3.8 dB
3.7. Test Result
The emission from the EUT was below the specified limits. The worst-case emissions are shown in section 12. The EUT complies the acceptance criterion and passes the test.
Report No. 068L169-RF-CE-P02V01
Page: 15 of 72 Version:1.0
4. Power Harmonics, Voltage Fluctuation and Flicker
4.1. Test Equipment
Item Instrument 4Manufacturer Type No/Serial No. Last Calibration
1 Power Harmonics Tester
SCHAFFNER Profline 2105-400
S/N: HK54148
June, 2006
2 Analyzer SCHAFFNER CCN 1000-1/X71887 June, 2006
3 No.3 Shielded Room
Note: All equipments are calibrated every one year.
4.2. Test Setup
4.3. Limits
Limits of Class A Harmonics Currents
Harmonics Order
n
Maximum Permissible harmonic current
A
Harmonics Order
n
Maximum Permissible harmonic current
A
Odd harmonics Even harmonics
3 2.30 2 1.08
5 1.14 4 0.43
7 0.77 6 0.30
9 0.40 8 ≤ n ≤ 40 0.23 * 8/n
11 0.33
13 0.21
15 ≤ n ≤ 39 0.15 * 15/n
Limits of Class B Harmonics Currents For Class B equipment, the harmonic of the input current shall not exceed the maximum permissible values given in table that is the limit of Class A multiplied by a factor of 1.5.
Power Analyzer Impedance Network
Power Source
EUT
Load Controller
PC
Non-Conducted
Report No. 068L169-RF-CE-P02V01
Page: 16 of 72 Version:1.0
Limits of Class C Harmonics Currents
Harmonics Order
n
Maximum Permissible harmonic current Expressed as a percentage of the input current
at the fundamental frequency %
2 2 3 30.λ* 5 10 7 7 9 5
11 ≤ n ≤ 39 (odd harmonics only)
3
*λ is the circuit power factor Limits of Class D Harmonics Currents
Harmonics Order
n
Maximum Permissible harmonic current per watt
mA/W
Maximum Permissible harmonic current
A 3 3.4 2.30 5 1.9 1.14 7 1.0 0.77 9 0.5 0.40 11 0.35 0.33
13 ≤ n ≤ 39 (odd harmonics only)
3.85/n See limit of Class A
4.4. Test Procedure
The EUT is supplied in series with power analyzer from a power source having the same normal voltage and frequency as the rated supply voltage and the equipment under test. And the rated voltage at the supply voltage of EUT of 0.94 times and 1.06 times shall be performed.
4.5. Test Specification
According to EN 61000-3-2:2000+A1: 2001, EN 61000-3-3:1995+A1: 2001
4.6. Uncertainty
± 3.23 %
4.7. Test Result
The measurement of the power harmonics, which test at the extremes of EUT’s supply range, was investigated and test result was shown in section 12. The EUT complies the acceptance criterion and passes the test.
Test Result: (See Test Result)
PASS FAIL Note: According to clause 7 of EN 61000-3-2: 2000, equipment with a rated power of 75W or less, no limits apply. The test result is only for reference.
Report No. 068L169-RF-CE-P02V01
Page: 17 of 72 Version:1.0
5. Electrostatic Discharge (ESD)
5.1. Test Equipment
Item Instrument Manufacturer Type No/Serial No. Last Calibration
1 ESD Simulator System SCHAFFNER NSG-438 S/N: 167 June, 2006
2 Horizontal Coupling Plane (HCP)
QuieTek HCP AL50 N/A
3 Vertical Coupling Plane (VCP)
QuieTek VCP AL50 N/A
4 No.3 Shielded Room
Note: All equipments are calibrated every one year.
5.2. Test Setup
5.3. Test Level
Item Environmental Phenomena Units Test Specification Performance Criteria
Enclosure Port
Electrostatic Discharge kV(Charge Voltage) ±8 Air Discharge
±4 Contact Discharge B
Metal Ground Plane
ESD Simulator
EUT Loads: Active Insulation
Horizontal Coupling Plane
Non-Conducted table 470K ohm Resistor
470K ohm Resistor
Vertical Coupling Plane
80cm
Report No. 068L169-RF-CE-P02V01
Page: 18 of 72 Version:1.0
5.4. Test Procedure
Direct application of discharges to the EUT: Contact discharge was applied only to conductive surfaces of the EUT. Air discharges were applied only to non-conductive surfaces of the EUT. During the test, it was performed with single discharges. For the single discharge time between successive single discharges will be keep longer 1 second. It was at least ten single discharges with positive and negative at the same selected point. The selected point, which was performed with electrostatic discharge, was marked on the red label of the EUT.
Indirect application of discharges to the EUT: Vertical Coupling Plane (VCP): The coupling plane, of dimensions 0.5m x 0.5m, is placed parallel to, and positioned at a distance 0.1m from, the EUT, with the Discharge Electrode touching the coupling plane. The four faces of the EUT will be performed with electrostatic discharge. It was at least ten single discharges with positive and negative at the same selected point. Horizontal Coupling Plane (HCP): The coupling plane is placed under to the EUT. The generator shall be positioned vertically at a distance of 0.1m from the EUT, with the Discharge Electrode touching the coupling plane. The four faces of the EUT will be performed with electrostatic discharge. It was at least ten single discharges with positive and negative at the same selected point.
5.5. Test Specification
According to EN 61000-4-2:1995+A1: 1998+A2: 2001
5.6. Uncertainty
± 6.003 %
5.7. Test Result
The measurement of the electrostatic discharge was investigated and test result was shown in section 12. The EUT complies the acceptance criterion and passes the test.
Report No. 068L169-RF-CE-P02V01
Page: 19 of 72 Version:1.0
6. Radiated Susceptibility (RS)
6.1. Test Equipment
Item Equipment Manufacturer Model No. / Serial No. Last Cal.
1 Signal Generator R & S SMY02 / 825454/029 Oct., 2006
2 Power Amplifier A & R 100W10000M7 / A285000010
N/A
3 RF Power Amplifier OPHIRRF 5022F / 1075 N/A
4 Bilog Antenna Chase CBL6112B / 2452 Sep., 2006
5 Power Meter R & S NRVD / 100219 Jan., 2006
6 Directional Coupler A & R DC6180 / 22735 Jan., 2006
7 No.5 EMC Fully Chamber
Note: All equipments are calibrated every one year.
6.2. Test Setup
6.3. Test Level
Item Environmental Phenomena Units Test Specification Performance Criteria
Enclosure Port
Radio-Frequency
Electromagnetic Field
Amplitude Modulated
MHz
V/m(Un-modulated, rms)
% AM (1kHz)
80-1000
1400-2000
3
80
A
EUT
Sensor
80cm
3 m
1m
Full-Anechoic Chamber
Power Amplifier
Signal Generator
Field Meter
Computer controller
Camera system
Camera Monitor
Antenna Mast
Load
Power Meter
Report No. 068L169-RF-CE-P02V01
Page: 20 of 72 Version:1.0
6.4. Test Procedure
The EUT and load, which are placed on a table that is 0.8 meter above ground, are placed with one coincident with the calibration plane such that the distance from antenna to the EUT was 3 meters. Both horizontal and vertical polarization of the antenna and four sides of the EUT are set on measurement. In order to judge the EUT performance, a CCD camera is used to monitor EUT screen.
All the scanning conditions are as follows: Condition of Test Remarks 1. Field Strength 3 V/m Level 2 2. Radiated Signal AM 80% Modulated with 1kHz sinusoidal audio signal 3. Scanning Frequency 80MHz - 1000MHz, 1400MHz - 2000MHz 4 Dwell Time 3 Seconds
5. Frequency step size ∆ f : 1% 6. The rate of Swept of Frequency 1.5 x 10-3 decades/s
6.5. Test Specification
According to EN 61000-4-3:1996+A1: 1998+A2: 2001
6.6. Uncertainty
± 6.17 %
6.7. Test Result
The measurement of the radiated susceptibility was investigated and test result was shown in section 12. The EUT complies the acceptance criterion and passes the test.
Report No. 068L169-RF-CE-P02V01
Page: 21 of 72 Version:1.0
7. Electrical Fast Transient/Burst (EFT/B)
7.1. Test Equipment
Item Instrument Manufacturer Type No/Serial No. Last Calibration
1 Fast Transient/Burst Generator
SCHAFFNER NSG 2050 S/N: 200124-031AR
June, 2006
2 No.2 Shielded Room
Note: All equipments are calibrated every one year.
7.2. Test Setup
Report No. 068L169-RF-CE-P02V01
Page: 22 of 72 Version:1.0
7.3. Test Level
Item Environmental Phenomena Units Test Specification Performance Criteria
Ports for signal lines and control lines
Fast Transients Common Mode
kV (Peak)
Tr/Th ns
Rep. Frequency kHz
+0.5
5/50
5
B
Input DC Power Ports
Fast Transients Common Mode
kV (Peak)
Tr/Th ns
Rep. Frequency kHz
+0.5
5/50
5
B
Input AC Power Ports
Fast Transients Common Mode
kV (Peak)
Tr/Th ns
Rep. Frequency kHz
+1
5/50
5
B
7.4. Test Procedure
The EUT and load are placed on a table that is 0.8 meter above a metal ground plane measured 1m*1m min. and 0.65mm thick min. And projected beyond the EUT by at least 0.1m on all sides. For Signal Ports and Telecommunication Ports:
The EFT interference signal is through a coupling clamp device couples to the signal and control lines of the EUT with burst noise for 1min.
For Input DC and AC Power Ports: The EUT is connected to the power mains through a coupling device that directly couples the EFT interference signal. Each of the Line and Neutral conductors is impressed with burst noise for 1 min. The length of power cord between the coupling device and the EUT shall be 1m.
7.5. Test Specification
According to EN 61000-4-4:1995+A1: 2001+A2: 2001
7.6. Uncertainty
± 8.80 %
7.7. Test Result
The measurement of the Electrical Fast Transient/Burst was investigated and test result was shown in section 12. The EUT complies the acceptance criterion and passes the test.
Report No. 068L169-RF-CE-P02V01
Page: 23 of 72 Version:1.0
8. Surge
8.1. Test Equipment
Item Instrument Manufacturer Type No/Serial No. Last Calibration
1 Surge Generator SCHAFFNER NSG 2050 S/N: 200124-031AR
June, 2006
2 No.6 Shielded Room
Note: All equipments are calibrated every one year.
8.2. Test Setup
8.3. Test Level
Item Environmental Phenomena Units Test Specification Performance Criteria
Telecommunication Ports (See 1) and 2))
Surges Line to Ground
Tr/Th us kV
1.2/50 (8/20) ± 1 B
Telecommunication Ports in Telecom Centres (See 1) and 2))
Surges Line to Ground
Tr/Th us kV
1.2/50 (8/20) ± 0.5 B
AC Input and AC Output Power Ports
Surges
Line to Line Line to Ground
Tr/Th us kV kV
1.2/50 (8/20) ±1 ± 2
B
AC Input and AC Output Power Ports in Telecom Centres
Surges
Line to Line Line to Ground
Tr/Th us kV kV
1.2/50 (8/20) ±0.5 ± 1
B
Notes: 1) Applicable only to ports which according to the manufacturer’s may directly to outdoor cables. 2) Where normal functioning cannot be achieved because of the impact of the CDN on the EUT, no immunity
test shall be required.
Surge Generator
EUT Load PC
Non-Conducted Table Non-Conducted Table
Report No. 068L169-RF-CE-P02V01
Page: 24 of 72 Version:1.0
8.4. Test Procedure
The EUT and its load are placed on a table that is 0.8 meter above a metal ground plane measured 1m*1m min. and 0.65mm thick min. And projected beyond the EUT by at least 0.1m on all sides. The length of power cord between the coupling device and the EUT shall be 2m or less. For Signal Ports and Telecommunication Ports
The disturbance signal is through a coupling and decoupling networks (CDN) device couples to the signal and Telecommunication lines of the EUT.
For Input and Output AC Power or DC Input and DC Output Power Ports: The EUT is connected to the power mains through a coupling device that directly couples the Surge interference signal. The surge noise shall be applied synchronized to the voltage phase at 00, 900, 1800, 2700 and the peak value of the a.c. voltage wave. (Positive and negative) Each of Line-Earth and Line-Line is impressed with a sequence of five surge voltages with interval of 1 min.
8.5. Test Specification
According to EN 61000-4-5:1995+A1+ 2001
8.6. Uncertainty
± 7.93 %
8.7. Test Result
The measurement of the Surge was investigated and test result was shown in section 12. The EUT complies the acceptance criterion and passes the test.
Report No. 068L169-RF-CE-P02V01
Page: 25 of 72 Version:1.0
9. Conducted Susceptibility (CS)
9.1. Test Equipment
Item Equipment Manufacturer Model No. / Serial No. Last Cal.
1 CS SYSTEM SCHAFFNER NSG 2070 March, 2006
2 CDN SCHAFFNER CDN M016S / 20822 Dec., 2005
3 CDN SCHAFFNER CDN M016S / 20823 Dec., 2005
4 FIXED PAD SCHAFFNER INA 2070-1 / 2115 N/A
5 EM Clamp KEMZ 801 / 21024 March, 2006
6 No.6 Shielded Room
Note: All equipments are calibrated every one year.
9.2. Test Setup
9.3. Test Level
Item Environmental Phenomena Units Test Specification Performance Criteria
AC Input and AC Output & DC Input and DC output Power Ports & Functional Earth Ports
Radio-Frequency
Common Mode.
Amplitude Modulated
MHz
V (rms, Unmodulated)
% AM (1kHz)
Source Impedance Ω
0.15-80
3
80
150
A
Aux equipment
EUT
CDN
RF-Generator
T2Ground Reference Plane
Non-Conducted Table
CDNAux
equipment
T
PA
Report No. 068L169-RF-CE-P02V01
Page: 26 of 72 Version:1.0
9.4. Test Procedure
The EUT are placed on a table that is 0.8 meter height, and a Ground reference plane on the table, EUT are placed upon table and use a 10cm insulation between the EUT and Ground reference plane. For Signal Ports and Telecommunication Ports
The disturbance signal is through a coupling and decoupling networks (CDN) or EM-clamp device couples to the signal and Telecommunication lines of the EUT.
For Input DC and AC Power Ports The EUT is connected to the power mains through a coupling and decoupling networks for power supply lines. And directly couples the disturbances signal into EUT. Used CDN-M2 for two wires or CDN-M3 for three wires.
All the scanning conditions are as follows: Condition of Test Remarks 1. Field Strength 130dBuV(3V) Level 2 2. Radiated Signal AM 80% Modulated with 1kHz sinusoidal audio signal 3. Scanning Frequency 0.15MHz – 80MHz 4 Dwell Time 3 Seconds
5. Frequency step size ∆ f : 1% 6. The rate of Swept of Frequency 1.5 x 10-3 decades/s
9.5. Test Specification
According to EN 61000-4-6:1996 +A1: 2001
9.6. Uncertainty
± 6.17 %
9.7. Test Result
The measurement of the Conducted Susceptibility was investigated and test result was shown in section 12. The EUT complies the acceptance criterion and passes the test.
Report No. 068L169-RF-CE-P02V01
Page: 27 of 72 Version:1.0
10. Voltage Dips and Interruption
10.1. Test Equipment
Item Instrument Manufacturer Type No/Serial No. Last Calibration
1 Voltage Dips Generator SCHAFFNER NSG 2050 S/N: 200124-031AR
June, 2006
2 No.6 Shielded Room
Note: All equipments are calibrated every one year.
10.2. Test Setup
10.3. Test Level
Item Environmental Phenomena Units Test Specification Performance Criteria
AC Input and AC Output Power Ports
Voltage Dips % Reduction
ms
30
10 B
Voltage Dips % Reduction
ms
60
100 C
Voltage Interruptions % Reduction
ms
> 95 %
5000 C
Voltage Dips/ Interruptions /Variations Simulator
EUT Load
To AC Line
Controller Computer Printer
Non-Conducted Table 80cm
AC Power Line to EUT
Report No. 068L169-RF-CE-P02V01
Page: 28 of 72 Version:1.0
10.4. Test Procedure
The EUT and its load are placed on a table which is 0.8 meter above a metal ground plane measured 1m*1m min. and 0.65mm thick min. And projected beyond the EUT by at least 0.1m on all sides. The power cord shall be used the shortest power cord as specified by the manufacturer. For Voltage Dips/ Interruptions test:
The selection of test voltage is based on the rated power range. If the operation range is large than 20% of lower power range, both end of specified voltage shall be tested. Otherwise, the typical voltage specification is selected as test voltage. The EUT is connected to the power mains through a coupling device that directly couples to the Voltage Dips and Interruption Generator. The EUT shall be tested for 30% voltage dip of supplied voltage and duration 10ms, with a sequence of three voltage dips with intervals of 10 seconds, for 60% voltage dip of supplied voltage and duration 100ms with a sequence of three voltage dips with intervals of 10 seconds, and for 95% voltage interruption of supplied voltage and duration 5000ms with a sequence of three voltage interruptions with intervals of 10 seconds. Voltage phase shifting are shall occur at 00, 450, 900 ,1350 ,1800 ,2250, 2700 ,3150 of the voltage.
10.5. Test Specification
According to EN 61000-4-11:1994+A1: 2001
10.6. Uncertainty
± 2.03 %
10.7. Test Result
The measurement of the Voltage Dips and Interruption was investigated and test result was shown in section 12. The EUT complies the acceptance criterion and passes the test.
Report No. 068L169-RF-CE-P02V01
Page: 29 of 72 Version:1.0
11. EMC Reduction Method During Compliance Testing
No modification was made during testing.
Report No. 068L169-RF-CE-P02V01
Page: 30 of 72 Version:1.0
12. Test Result
The test results in the emission and the immunity were performed according to the requirements of measurement standard and process. Quietek Corporation is assumed full responsibility for the accuracy and completeness of these measurements. The test data of the emission is listed as below. All the tests were carried out with the EUT in normal operation, which was defined as:
EMI Mode Mode1: Normal Operation (Adapter 1) Mode2: Normal Operation (Adapter 2) Mode3: Normal Operation (Adapter 3)
EMS Mode Mode1: Normal Operation (Adapter 1) Mode2: Normal Operation (Adapter 2) Mode3: Normal Operation (Adapter 3)
Report No. 068L169-RF-CE-P02V01
Page: 31 of 72 Version:1.0
12.1. Test Data of Conducted Emission
Product : MEGA BOOK Test Item : Conducted Emission Test Site : No.1 Shielded Room Power Line : Line 1 Test Mode : Mode1: Normal Operation (Adapter 1)
Frequency Correct Reading Measurement Margin Limit
Factor Level Level MHz dB dBuV dBuV dB dBuV
LINE 1 Quasi-Peak
0.193 0.202 46.120 46.322 -18.449 64.771 0.326 0.214 37.130 37.344 -23.627 60.971 0.584 0.217 36.800 37.017 -18.983 56.000 1.689 0.262 34.790 35.052 -20.948 56.000 3.959 0.352 34.070 34.422 -21.578 56.000
16.818 0.924 29.460 30.384 -29.616 60.000
Average 0.193 0.202 44.370 44.572 -10.199 54.771 0.326 0.214 34.220 34.434 -16.537 50.971 0.584 0.217 35.520 35.737 -10.263 46.000 1.689 0.262 33.480 33.742 -12.258 46.000 3.959 0.352 30.930 31.282 -14.718 46.000
16.818 0.924 22.300 23.224 -26.776 50.000
Note: 1. All Reading Levels are Quasi-Peak and Average value. 2. " " means the worst emission level. 3. Measurement Level = Reading Level + Correct Factor
Report No. 068L169-RF-CE-P02V01
Page: 32 of 72 Version:1.0
Product : MEGA BOOK Test Item : Conducted Emission Test Site : No.1 Shielded Room Power Line : Line 2 Test Mode : Mode1: Normal Operation (Adapter 1)
Frequency Correct Reading Measurement Margin Limit
Factor Level Level MHz dB dBuV dBuV dB dBuV
LINE 2 Quasi-Peak
0.193 0.202 46.380 46.582 -18.189 64.771 0.388 0.215 36.620 36.835 -22.365 59.200 0.584 0.217 36.770 36.987 -19.013 56.000 1.361 0.248 35.930 36.178 -19.822 56.000 2.400 0.292 35.840 36.132 -19.868 56.000
16.537 0.920 33.500 34.420 -25.580 60.000
Average 0.193 0.202 44.500 44.702 -10.069 54.771 0.388 0.215 33.420 33.635 -15.565 49.200 0.584 0.217 35.520 35.737 -10.263 46.000 1.361 0.248 34.600 34.848 -11.152 46.000 2.400 0.292 33.570 33.862 -12.138 46.000
16.537 0.920 27.900 28.820 -21.180 50.000
Note: 1. All Reading Levels are Quasi-Peak and Average value. 2. " " means the worst emission level. 3. Measurement Level = Reading Level + Correct Factor
Report No. 068L169-RF-CE-P02V01
Page: 33 of 72 Version:1.0
Product : MEGA BOOK Test Item : Conducted Emission Test Site : No.1 Shielded Room Power Line : Line 1 Test Mode : Mode2: Normal Operation (Adapter 2)
Frequency Correct Reading Measurement Margin Limit
Factor Level Level MHz dB dBuV dBuV dB dBuV
LINE 1 Quasi-Peak
0.291 0.300 40.460 40.760 -21.211 61.971 0.420 0.300 45.850 46.150 -12.136 58.286 0.846 0.310 47.200 47.510 -8.490 56.000 1.685 0.330 43.580 43.910 -12.090 56.000 4.228 0.410 37.410 37.820 -18.180 56.000 7.598 0.520 34.070 34.590 -25.410 60.000
Average
0.291 0.300 21.200 21.500 -30.471 51.971 0.420 0.300 32.350 32.650 -15.636 48.286 0.846 0.310 31.210 31.520 -14.480 46.000 1.685 0.330 27.850 28.180 -17.820 46.000 4.228 0.410 23.000 23.410 -22.590 46.000 7.598 0.520 21.250 21.770 -28.230 50.000
Note: 1. All Reading Levels are Quasi-Peak and Average value. 2. " " means the worst emission level. 3. Measurement Level = Reading Level + Correct Factor
Report No. 068L169-RF-CE-P02V01
Page: 34 of 72 Version:1.0
Product : MEGA BOOK Test Item : Conducted Emission Test Site : No.1 Shielded Room Power Line : Line 2 Test Mode : Mode2: Normal Operation (Adapter 2)
Frequency Correct Reading Measurement Margin Limit
Factor Level Level MHz dB dBuV dBuV dB dBuV
LINE 2 Quasi-Peak
0.244 0.300 38.490 38.790 -24.524 63.314 0.396 0.310 44.460 44.770 -14.201 58.971 0.826 0.320 46.590 46.910 -9.090 56.000 1.611 0.340 35.820 36.160 -19.840 56.000 3.455 0.387 32.620 33.007 -22.993 56.000 9.634 0.490 31.010 31.500 -28.500 60.000
Average
0.244 0.300 18.940 19.240 -34.074 53.314 0.396 0.310 28.190 28.500 -20.471 48.971 0.826 0.320 30.070 30.390 -15.610 46.000 1.611 0.340 26.200 26.540 -19.460 46.000 3.455 0.387 24.230 24.617 -21.383 46.000 9.634 0.490 20.530 21.020 -28.980 50.000
Note: 1. All Reading Levels are Quasi-Peak and Average value. 2. " " means the worst emission level. 3. Measurement Level = Reading Level + Correct Factor
Report No. 068L169-RF-CE-P02V01
Page: 35 of 72 Version:1.0
Product : MEGA BOOK Test Item : Conducted Emission Test Site : No.1 Shielded Room Power Line : Line 1 Test Mode : Mode3: Normal Operation (Adapter 3)
Frequency Correct Reading Measurement Margin Limit
Factor Level Level MHz dB dBuV dBuV dB dBuV
LINE 1 Quasi-Peak
0.196 0.679 46.590 47.269 -17.417 64.686 0.263 0.314 40.880 41.194 -21.577 62.771 0.463 0.300 40.230 40.530 -16.527 57.057 0.724 0.310 40.230 40.540 -15.460 56.000 1.587 0.330 34.080 34.410 -21.590 56.000 3.705 0.390 38.300 38.690 -17.310 56.000
Average
0.196 0.679 39.990 40.669 -14.017 54.686 0.263 0.314 35.710 36.024 -16.747 52.771 0.463 0.300 39.060 39.360 -7.697 47.057 0.724 0.310 35.000 35.310 -10.690 46.000 1.587 0.330 31.710 32.040 -13.960 46.000 3.705 0.390 30.590 30.980 -15.020 46.000
Note: 1. All Reading Levels are Quasi-Peak and Average value. 2. " " means the worst emission level. 3. Measurement Level = Reading Level + Correct Factor
Report No. 068L169-RF-CE-P02V01
Page: 36 of 72 Version:1.0
Product : MEGA BOOK Test Item : Conducted Emission Test Site : No.1 Shielded Room Power Line : Line 2 Test Mode : Mode3: Normal Operation (Adapter 3)
Frequency Correct Reading Measurement Margin Limit
Factor Level Level MHz dB dBuV dBuV dB dBuV
LINE 2 Quasi-Peak
0.154 0.300 41.520 41.820 -24.066 65.886 0.197 0.300 49.000 49.300 -15.357 64.657 0.463 0.310 39.540 39.850 -17.207 57.057 0.724 0.312 39.340 39.652 -16.348 56.000 3.705 0.390 39.400 39.790 -16.210 56.000
25.630 1.090 28.980 30.070 -29.930 60.000
Average 0.154 0.300 15.330 15.630 -40.256 55.886 0.197 0.300 42.310 42.610 -12.047 54.657 0.463 0.310 37.790 38.100 -8.957 47.057 0.724 0.312 33.240 33.552 -12.448 46.000 3.705 0.390 31.790 32.180 -13.820 46.000
25.630 1.090 22.000 23.090 -26.910 50.000
Note: 1. All Reading Levels are Quasi-Peak and Average value. 2. " " means the worst emission level. 3. Measurement Level = Reading Level + Correct Factor
Report No. 068L169-RF-CE-P02V01
Page: 37 of 72 Version:1.0
Product : MEGA BOOK Test Item : Impedance Stabilization Network Test Site : No.1 Shielded Room Test Mode : Mode1: Normal Operation (Adapter 1) (ISN-100Mbps)
Frequency Correct Reading Measurement Margin Limit
Factor Level Level MHz dB dBuV dBuV dB dBuV
Quasi-Peak 0.349 9.784 35.310 45.094 -33.220 78.314 0.823 9.750 44.470 54.220 -19.780 74.000 2.048 9.747 46.610 56.357 -17.643 74.000 9.935 9.812 49.140 58.952 -25.048 84.000
16.228 9.856 57.330 67.186 -16.814 84.000 23.127 9.918 59.320 69.238 -14.762 84.000
Average
0.349 9.784 31.380 41.164 -27.150 68.314 0.823 9.750 35.470 45.220 -18.780 64.000 2.048 9.747 45.540 55.287 -8.713 64.000 9.935 9.812 45.810 55.622 -18.378 74.000
16.228 9.856 53.960 63.816 -10.184 74.000 23.127 9.918 56.890 66.808 -7.192 74.000
Note: 1. All Reading Levels are Quasi-Peak and Average value. 2. " " means the worst emission level. 3. Measurement Level = Reading Level + Correct Factor
Report No. 068L169-RF-CE-P02V01
Page: 38 of 72 Version:1.0
Product : MEGA BOOK Test Item : Impedance Stabilization Network Test Site : No.1 Shielded Room Test Mode : Mode1: Normal Operation (Adapter 1) (ISN-10Mbps)
Frequency Correct Reading Measurement Margin Limit
Factor Level Level MHz dB dBuV dBuV dB dBuV
Quasi-Peak 0.825 9.750 43.940 53.690 -20.310 74.000 2.443 9.742 43.950 53.692 -20.308 74.000 7.916 9.795 51.290 61.085 -22.915 84.000
10.002 9.813 62.820 72.633 -11.367 84.000 13.783 9.833 46.560 56.393 -27.607 84.000 27.396 9.965 47.210 57.175 -26.825 84.000
Average
0.825 9.750 34.060 43.810 -20.190 64.000 2.443 9.742 40.620 50.362 -13.638 64.000 7.916 9.795 46.080 55.875 -18.125 74.000
10.002 9.813 52.190 62.003 -11.997 74.000 13.783 9.833 41.340 51.173 -22.827 74.000 27.396 9.965 40.500 50.465 -23.535 74.000
Note: 1. All Reading Levels are Quasi-Peak and Average value. 2. " " means the worst emission level. 3. Measurement Level = Reading Level + Correct Factor
Report No. 068L169-RF-CE-P02V01
Page: 39 of 72 Version:1.0
Product : MEGA BOOK Test Item : Impedance Stabilization Network Test Site : No.1 Shielded Room Test Mode : Mode1: Normal Operation (Adapter 1) (ISN-Telecom)
Frequency Correct Reading Measurement Margin Limit
Factor Level Level MHz dB dBuV dBuV dB dBuV
Quasi-Peak 0.162 9.802 53.920 63.722 -19.935 83.657 0.193 9.798 48.550 58.348 -24.423 82.771 2.047 9.747 49.900 59.647 -14.353 74.000 3.084 9.751 39.710 49.461 -24.539 74.000 4.841 9.764 34.050 43.814 -30.186 74.000
21.654 9.899 41.000 50.899 -23.101 74.000
Average 0.162 9.802 51.520 61.322 -12.335 73.657 0.193 9.798 44.280 54.078 -18.693 72.771 2.047 9.747 49.700 59.447 -4.553 64.000 3.084 9.751 38.390 48.141 -15.859 64.000 4.841 9.764 29.590 39.354 -24.646 64.000
21.654 9.899 35.580 45.479 -18.521 64.000
Note: 1. All Reading Levels are Quasi-Peak and Average value. 2. " " means the worst emission level. 3. Measurement Level = Reading Level + Correct Factor
Report No. 068L169-RF-CE-P02V01
Page: 40 of 72 Version:1.0
12.2. Test Data of Radiated Emission
Product : MEGA BOOK Test Item : General Radiated Emission Test Site : No.3 OATS Test Mode : Mode1: Normal Operation (Adapter 1)
Frequency Correct Reading Measurement Margin Limit
Factor Level Level MHz dB dBuV dBuV/m dB dBuV/m
Horizontal 148.460 12.801 5.230 18.031 -11.969 30.000 156.960 12.362 4.670 17.032 -12.968 30.000 240.000 14.124 15.180 29.304 -7.696 37.000 300.000 16.708 4.150 20.857 -16.143 37.000 401.800 20.518 3.860 24.378 -12.622 37.000 480.120 22.175 11.000 33.175 -3.825 37.000 600.030 24.440 2.130 26.570 -10.430 37.000 800.000 26.896 7.000 33.896 -3.104 37.000 835.828 27.419 3.540 30.959 -6.041 37.000 975.000 28.828 1.790 30.618 -6.382 37.000
Vertical 69.993 7.002 15.540 22.543 -7.457 30.000
120.000 13.802 9.710 23.512 -6.488 30.000 125.000 14.027 12.870 26.897 -3.103 30.000 148.900 12.773 9.400 22.172 -7.828 30.000 160.000 12.301 -2.380 9.921 -20.079 30.000 240.000 14.124 9.030 23.154 -13.846 37.000 320.000 17.560 6.310 23.870 -13.130 37.000 401.800 20.518 7.730 28.248 -8.752 37.000 600.030 24.440 2.030 26.470 -10.530 37.000 800.000 26.896 7.000 33.896 -3.104 37.000 835.828 27.419 6.400 33.819 -3.181 37.000
Note:
1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average measurements as necessary.
2. “ ” means the worst emission level. 3. Measurement Level = Reading Level + Correct Factor
Report No. 068L169-RF-CE-P02V01
Page: 41 of 72 Version:1.0
Product : MEGA BOOK Test Item : General Radiated Emission Test Site : No.3 OATS Test Mode : Mode2: Normal Operation (Adapter 2)
Frequency Correct Reading Measurement Margin Limit
Factor Level Level MHz dB dBuV dBuV/m dB dBuV/m
Horizontal 175.000 11.478 14.560 26.038 -3.962 30.000 200.000 11.613 12.270 23.883 -6.117 30.000 393.233 20.102 8.860 28.961 -8.039 37.000 480.120 22.175 6.910 29.085 -7.915 37.000 720.030 25.921 0.470 26.391 -10.609 37.000 800.000 26.896 6.590 33.486 -3.514 37.000 803.600 26.937 4.130 31.067 -5.933 37.000
Vertical 117.200 13.699 12.270 25.968 -4.032 30.000 124.000 13.996 8.520 22.516 -7.484 30.000 135.500 13.671 7.830 21.500 -8.500 30.000 150.000 12.700 11.330 24.030 -5.970 30.000 200.000 11.613 14.000 25.613 -4.387 30.000 250.000 15.286 10.250 25.536 -11.464 37.000 368.655 19.294 7.650 26.945 -10.055 37.000 500.000 22.412 3.430 25.842 -11.158 37.000 750.040 26.405 4.010 30.415 -6.585 37.000 800.000 26.896 7.100 33.996 -3.004 37.000 803.600 26.937 5.960 32.897 -4.103 37.000
Note:
1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average measurements as necessary.
2. “ ” means the worst emission level. 3. Measurement Level = Reading Level + Correct Factor
Report No. 068L169-RF-CE-P02V01
Page: 42 of 72 Version:1.0
Product : MEGA BOOK Test Item : General Radiated Emission Test Site : No.3 OATS Test Mode : Mode3: Normal Operation (Adapter 3)
Frequency Correct Reading Measurement Margin Limit
Factor Level Level MHz dB dBuV dBuV/m dB dBuV/m
Horizontal 68.000 6.805 13.500 20.304 -9.696 30.000
175.000 11.478 13.980 25.458 -4.542 30.000 200.000 11.613 11.320 22.933 -7.067 30.000 393.233 20.102 6.980 27.081 -9.919 37.000 480.120 22.175 6.910 29.085 -7.915 37.000 720.000 25.920 3.510 29.430 -7.570 37.000 800.000 26.896 5.900 32.796 -4.204 37.000 803.600 26.937 5.330 32.267 -4.733 37.000
Vertical 117.200 13.699 12.100 25.798 -4.202 30.000 150.000 12.700 12.100 24.800 -5.200 30.000 200.000 11.613 13.500 25.113 -4.887 30.000 250.000 15.286 10.250 25.536 -11.464 37.000 368.655 19.294 7.650 26.945 -10.055 37.000 500.000 22.412 5.710 28.122 -8.878 37.000 750.040 26.405 4.010 30.415 -6.585 37.000 800.000 26.896 7.000 33.896 -3.104 37.000 803.600 26.937 5.840 32.777 -4.223 37.000
Note:
1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average measurements as necessary.
2. “ ” means the worst emission level. 3. Measurement Level = Reading Level + Correct Factor
Report No. 068L169-RF-CE-P02V01
Page: 43 of 72 Version:1.0
12.3. Test Data of Power Harmonics, Voltage Flucturation and Flicker
Product : MEGA BOOK Test Item : Power Harmonics Classification : Class D Test Mode : Mode1: Normal Operation (Adapter 1)
Test Result: Pass Source qualification: Normal
Current & voltage waveforms
-0.9-0.6-0.30.00.30.60.9
-300-200-1000100200300
Cur
rent
(Am
ps)
Voltage (V
olts)
Harmonics and Class D limit line European Limits
0.000.050.100.150.200.250.300.35
Cur
rent
RM
S(A
mps
)
Harmonic #4 8 12 16 20 24 28 32 36 40
Test result: Pass Worst harmonic was #0 with 0.00% of the limit.
Report No. 068L169-RF-CE-P02V01
Page: 44 of 72 Version:1.0
Test Result: Pass Source qualification: Normal THC(A): 0.00 I-THD(%): 0.00 POHC(A): 0.000 POHC Limit(A): 0.000 Highest parameter values during test:
V_RMS (Volts): 229.82 Frequency(Hz): 50.00 I_Peak (Amps): 0.641 I_RMS (Amps): 0.329 I_Fund (Amps): 0.310 Crest Factor: 1.977 Power (Watts): 72.2 Power Factor: 0.955
Harm# Harms(avg) 100%Limit %of Limit Harms(max) 150%Limit %of Limit Status 2 0.000 3 0.040 0.245 0.0 0.041 0.368 0.00 Pass 4 0.000 5 0.010 0.137 0.0 0.010 0.199 0.00 Pass 6 0.000 7 0.009 0.072 0.0 0.009 0.108 0.00 Pass 8 0.000 9 0.007 0.036 0.0 0.007 0.054 0.00 Pass 10 0.000 11 0.005 0.025 0.0 0.006 0.038 0.00 Pass 12 0.000 13 0.004 0.022 0.0 0.004 0.032 0.00 Pass 14 0.000 15 0.003 0.019 0.0 0.003 0.027 0.00 Pass 16 0.000 17 0.002 0.017 0.0 0.002 0.024 0.00 Pass 18 0.000 19 0.002 0.015 0.0 0.003 0.022 0.00 Pass 20 0.000 21 0.002 0.013 0.0 0.003 0.019 0.00 Pass 22 0.000 23 0.002 0.012 0.0 0.002 0.018 0.00 Pass 24 0.000 25 0.002 0.011 0.0 0.002 0.017 0.00 Pass 26 0.000 27 0.001 0.010 0.0 0.002 0.015 0.00 Pass 28 0.000 29 0.001 0.010 0.0 0.001 0.014 0.00 Pass 30 0.000 31 0.001 0.009 0.0 0.001 0.013 0.00 Pass 32 0.000 33 0.001 0.008 0.0 0.001 0.013 0.00 Pass 34 0.000 35 0.001 0.008 0.0 0.001 0.012 0.00 Pass 36 0.000 37 0.001 0.008 0.0 0.001 0.011 0.00 Pass 38 0.001 39 0.001 0.007 0.0 0.001 0.011 0.00 Pass 40 0.001
1.Dynamic limits were applied for this test. The highest harmonics values in the above table may not occur at the same
window as the maximum harmonics/limit ratio.
2:According to EN61000-3-2 paragraph 7 the note 1 and 2 are valid for all applications having an active input power >75W.
Others the result should be pass.
Report No. 068L169-RF-CE-P02V01
Page: 45 of 72 Version:1.0
Product : MEGA BOOK Test Item : Voltage Fluctuations and Flicker Test Mode : Mode1: Normal Operation (Adapter 1)
Test Result: Pass Status: Test Completed
Psti and limit line European Limits
0.25
0.50
0.75
1.00
Pst
14:4
4:0
2
Plt and limit line
0.10.20.30.40.50.6
Plt
14:4
4:0
2
Parameter values recorded during the test: Vrms at the end of test (Volt): 229.76 Highest dt (%): 0.00 Test limit (%): 3.30 Pass Time(mS) > dt: 0.0 Test limit (mS): 500.0 Pass Highest dc (%): 0.00 Test limit (%): 3.30 Pass Highest dmax (%): 0.00 Test limit (%): 4.00 Pass Highest Pst (10 min. period): 0.160 Test limit: 1.000 Pass Highest Plt (2 hr. period): 0.070 Test limit: 0.650 Pass
Report No. 068L169-RF-CE-P02V01
Page: 46 of 72 Version:1.0
Product : MEGA BOOK Test Item : Power Harmonics Classification : Class D Test Mode : Mode2: Normal Operation (Adapter 2)
Test Result: Pass Source qualification: Normal
Current & voltage waveforms
-0.6-0.4-0.20.00.20.40.6
-300-200-1000100200300
Cur
rent
(Am
ps)
Voltage (V
olts)
Harmonics and Class D limit line European Limits
0.000.050.100.150.200.250.300.35
Cur
rent
RM
S(A
mps
)
Harmonic #4 8 12 16 20 24 28 32 36 40
Test result: Pass Worst harmonic was #0 with 0.00% of the limit.
Report No. 068L169-RF-CE-P02V01
Page: 47 of 72 Version:1.0
Test Result: Pass Source qualification: Normal THC(A): 0.00 I-THD(%): 0.00 POHC(A): 0.000 POHC Limit(A): 0.000 Highest parameter values during test:
V_RMS (Volts): 229.79 Frequency(Hz): 50.00 I_Peak (Amps): 0.571 I_RMS (Amps): 0.328 I_Fund (Amps): 0.312 Crest Factor: 1.757 Power (Watts): 71.4 Power Factor: 0.947
Harm# Harms(avg) 100%Limit %of Limit Harms(max) 150%Limit %of Limit Status 2 0.000 3 0.062 0.243 0.0 0.062 0.364 0.00 Pass 4 0.000 5 0.031 0.136 0.0 0.031 0.202 0.00 Pass 6 0.000 7 0.013 0.071 0.0 0.013 0.107 0.00 Pass 8 0.000 9 0.001 0.036 0.0 0.001 0.053 0.00 Pass 10 0.000 11 0.004 0.025 0.0 0.005 0.037 0.00 Pass 12 0.000 13 0.005 0.021 0.0 0.005 0.032 0.00 Pass 14 0.000 15 0.003 0.019 0.0 0.003 0.027 0.00 Pass 16 0.000 17 0.001 0.016 0.0 0.002 0.024 0.00 Pass 18 0.000 19 0.002 0.014 0.0 0.002 0.022 0.00 Pass 20 0.000 21 0.002 0.013 0.0 0.002 0.020 0.00 Pass 22 0.000 23 0.002 0.012 0.0 0.002 0.018 0.00 Pass 24 0.000 25 0.001 0.011 0.0 0.001 0.016 0.00 Pass 26 0.000 27 0.001 0.010 0.0 0.001 0.015 0.00 Pass 28 0.000 29 0.002 0.009 0.0 0.002 0.014 0.00 Pass 30 0.000 31 0.001 0.009 0.0 0.002 0.013 0.00 Pass 32 0.000 33 0.001 0.008 0.0 0.001 0.012 0.00 Pass 34 0.000 35 0.001 0.008 0.0 0.001 0.012 0.00 Pass 36 0.000 37 0.001 0.007 0.0 0.001 0.011 0.00 Pass 38 0.000 39 0.001 0.007 0.0 0.001 0.010 0.00 Pass 40 0.000
1.Dynamic limits were applied for this test. The highest harmonics values in the above table may not occur at the same
window as the maximum harmonics/limit ratio.
2:According to EN61000-3-2 paragraph 7 the note 1 and 2 are valid for all applications having an active input power >75W.
Others the result should be pass.
Report No. 068L169-RF-CE-P02V01
Page: 48 of 72 Version:1.0
Product : MEGA BOOK Test Item : Voltage Fluctuations and Flicker Test Mode : Mode2: Normal Operation (Adapter 2)
Test Result: Pass Status: Test Completed
Psti and limit line European Limits
0.25
0.50
0.75
1.00
Pst
23:0
2:2
7
Plt and limit line
0.10.20.30.40.50.6
Plt
23:0
2:2
7
Parameter values recorded during the test: Vrms at the end of test (Volt): 229.67 Highest dt (%): 0.00 Test limit (%): 3.30 Pass Time(mS) > dt: 0.0 Test limit (mS): 500.0 Pass Highest dc (%): 0.00 Test limit (%): 3.30 Pass Highest dmax (%): 0.00 Test limit (%): 4.00 Pass Highest Pst (10 min. period): 0.160 Test limit: 1.000 Pass Highest Plt (2 hr. period): 0.070 Test limit: 0.650 Pass
Report No. 068L169-RF-CE-P02V01
Page: 49 of 72 Version:1.0
Product : MEGA BOOK Test Item : Power Harmonics Classification : Class D Test Mode : Mode3: Normal Operation (Adapter 3)
Test Result: Pass Source qualification: Normal
Current & voltage waveforms
-6-4-20246
-300-200-1000100200300
Cur
rent
(Am
ps)
Voltage (V
olts)
Harmonics and Class D limit line European Limits
0.000.050.100.150.200.250.300.35
Cur
rent
RM
S(A
mps
)
Harmonic #4 8 12 16 20 24 28 32 36 40
Test result: Pass Worst harmonic was #0 with 0.00% of the limit.
Report No. 068L169-RF-CE-P02V01
Page: 50 of 72 Version:1.0
Test Result: Pass Source qualification: Normal THC(A): 0.00 I-THD(%): 0.00 POHC(A): 0.000 POHC Limit(A): 0.000 Highest parameter values during test:
V_RMS (Volts): 229.79 Frequency(Hz): 50.00 I_Peak (Amps): 3.808 I_RMS (Amps): 0.768 I_Fund (Amps): 0.308 Crest Factor: 5.083 Power (Watts): 71.4 Power Factor: 0.407
Harm# Harms(avg) 100%Limit %of Limit Harms(max) 150%Limit %of Limit Status 2 0.003 3 0.293 0.243 0.0 0.297 0.363 0.00 Pass 4 0.003 5 0.280 0.136 0.0 0.284 0.203 0.00 Pass 6 0.003 7 0.263 0.071 0.0 0.266 0.107 0.00 Pass 8 0.003 9 0.241 0.036 0.0 0.244 0.054 0.00 Pass 10 0.003 11 0.215 0.025 0.0 0.219 0.037 0.00 Pass 12 0.003 13 0.188 0.021 0.0 0.191 0.032 0.00 Pass 14 0.003 15 0.160 0.019 0.0 0.163 0.027 0.00 Pass 16 0.003 17 0.132 0.016 0.0 0.135 0.024 0.00 Pass 18 0.003 19 0.106 0.014 0.0 0.109 0.022 0.00 Pass 20 0.003 21 0.082 0.013 0.0 0.085 0.020 0.00 Pass 22 0.002 23 0.062 0.012 0.0 0.064 0.018 0.00 Pass 24 0.002 25 0.046 0.011 0.0 0.047 0.016 0.00 Pass 26 0.002 27 0.034 0.010 0.0 0.035 0.015 0.00 Pass 28 0.001 29 0.026 0.009 0.0 0.026 0.014 0.00 Pass 30 0.001 31 0.021 0.009 0.0 0.022 0.013 0.00 Pass 32 0.001 33 0.018 0.008 0.0 0.019 0.012 0.00 Pass 34 0.001 35 0.017 0.008 0.0 0.017 0.012 0.00 Pass 36 0.000 37 0.014 0.007 0.0 0.015 0.011 0.00 Pass 38 0.000 39 0.012 0.007 0.0 0.012 0.011 0.00 Pass 40 0.000
1.Dynamic limits were applied for this test. The highest harmonics values in the above table may not occur at the same
window as the maximum harmonics/limit ratio.
2:According to EN61000-3-2 paragraph 7 the note 1 and 2 are valid for all applications having an active input power >75W.
Others the result should be pass.
Report No. 068L169-RF-CE-P02V01
Page: 51 of 72 Version:1.0
Product : MEGA BOOK Test Item : Voltage Fluctuations and Flicker Test Mode : Mode3: Normal Operation (Adapter 3)
Test Result: Pass Status: Test Completed
Psti and limit line European Limits
0.25
0.50
0.75
1.00
Pst
23:2
5:3
2
Plt and limit line
0.10.20.30.40.50.6
Plt
23:2
5:3
2
Parameter values recorded during the test: Vrms at the end of test (Volt): 229.65 Highest dt (%): 0.00 Test limit (%): 3.30 Pass Time(mS) > dt: 0.0 Test limit (mS): 500.0 Pass Highest dc (%): 0.00 Test limit (%): 3.30 Pass Highest dmax (%): 0.00 Test limit (%): 4.00 Pass Highest Pst (10 min. period): 0.160 Test limit: 1.000 Pass Highest Plt (2 hr. period): 0.070 Test limit: 0.650 Pass
Report No. 068L169-RF-CE-P02V01
Page: 52 of 72 Version:1.0
12.4. Test Data of Electrostatic Discharge
Product : MEGA BOOK Test Item : Electrostatic Discharge Test Site : No.3 Shielded Room Test Mode : Mode1: Normal Operation (Adapter 1)
Item Amount of Discharge
Voltage Required Criteria
Complied To Criteria (A, B, C)
Results
Air Discharge 10
10
+8kV
-8kV
B
B
B
B
Pass
Pass
Contact Discharge 25
25
+4kV
-4kV
B
B
B
B
Pass
Pass
Indirect Discharge
(HCP)
50
50
+4kV
-4kV
B
B
B
B
Pass
Pass
Indirect Discharge
(VCP Front)
50
50
+4kV
-4kV
B
B
B
B
Pass
Pass
Indirect Discharge
(VCP Left)
50
50
+4kV
-4kV
B
B
B
B
Pass
Pass
Indirect Discharge
(VCP Back)
50
50
+4kV
-4kV
B
B
B
B
Pass
Pass
Indirect Discharge
(VCP Right)
50
50
+4kV
-4kV
B
B
B
B
Pass
Pass
Note: The testing performed is from lowest level up to the highest level as required by standard, but only highest level is shown on the report.
NR: No Requirement
Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss/Error of function Additional Information
EUT stopped operation and could / could not be reset by operator at kV. No false alarms or other malfunctions were observed during or after the test.
Report No. 068L169-RF-CE-P02V01
Page: 53 of 72 Version:1.0
Product : MEGA BOOK Test Item : Electrostatic Discharge Test Site : No.3 Shielded Room Test Mode : Mode2: Normal Operation (Adapter 2)
Item Amount of Discharge
Voltage Required Criteria
Complied To Criteria (A, B, C)
Results
Air Discharge 10
10
+8kV
-8kV
B
B
B
B
Pass
Pass
Contact Discharge 25
25
+4kV
-4kV
B
B
B
B
Pass
Pass
Indirect Discharge
(HCP)
50
50
+4kV
-4kV
B
B
A
A
Pass
Pass
Indirect Discharge
(VCP Front)
50
50
+4kV
-4kV
B
B
A
A
Pass
Pass
Indirect Discharge
(VCP Left)
50
50
+4kV
-4kV
B
B
A
A
Pass
Pass
Indirect Discharge
(VCP Back)
50
50
+4kV
-4kV
B
B
A
A
Pass
Pass
Indirect Discharge
(VCP Right)
50
50
+4kV
-4kV
B
B
A
A
Pass
Pass
Note: The testing performed is from lowest level up to the highest level as required by standard, but only highest level is shown on the report.
NR: No Requirement
Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss/Error of function Additional Information
EUT stopped operation and could / could not be reset by operator at kV. No false alarms or other malfunctions were observed during or after the test.
Report No. 068L169-RF-CE-P02V01
Page: 54 of 72 Version:1.0
Product : MEGA BOOK Test Item : Electrostatic Discharge Test Site : No.3 Shielded Room Test Mode : Mode3: Normal Operation (Adapter 3)
Item Amount of Discharge
Voltage Required Criteria
Complied To Criteria (A, B, C)
Results
Air Discharge 10
10
+8kV
-8kV
B
B
B
B
Pass
Pass
Contact Discharge 25
25
+4kV
-4kV
B
B
B
B
Pass
Pass
Indirect Discharge
(HCP)
50
50
+4kV
-4kV
B
B
A
A
Pass
Pass
Indirect Discharge
(VCP Front)
50
50
+4kV
-4kV
B
B
A
A
Pass
Pass
Indirect Discharge
(VCP Left)
50
50
+4kV
-4kV
B
B
A
A
Pass
Pass
Indirect Discharge
(VCP Back)
50
50
+4kV
-4kV
B
B
A
A
Pass
Pass
Indirect Discharge
(VCP Right)
50
50
+4kV
-4kV
B
B
A
A
Pass
Pass
Note: The testing performed is from lowest level up to the highest level as required by standard, but only highest level is shown on the report.
NR: No Requirement
Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss/Error of function Additional Information
EUT stopped operation and could / could not be reset by operator at kV. No false alarms or other malfunctions were observed during or after the test.
Report No. 068L169-RF-CE-P02V01
Page: 55 of 72 Version:1.0
12.5. Test Data of Radiated Susceptibility
Product : MEGA BOOK Test Item : Radiated Susceptibility Test Site : No.5 EMC fully Chamber Test Mode : Mode1: Normal Operation (Adapter 1)
Frequency (MHz)
Position (Angle)
Polarity(H or V)
Field Strength (V/m)
Required Criteria
Complied To Criteria
(A, B, C) Results
80-1000 Front H 3 A A Pass 80-1000 Front V 3 A A Pass 80-1000 Back H 3 A A Pass 80-1000 Back V 3 A A Pass 80-1000 Left H 3 A A Pass 80-1000 Left V 3 A A Pass 80-1000 Right H 3 A A Pass 80-1000 Right V 3 A A Pass 80-1000 Top H 3 A A Pass 80-1000 Top V 3 A A Pass 80-1000 Down H 3 A A Pass 80-1000 Down V 3 A A Pass
1400-2000 Front H 3 A A Pass 1400-2000 Front V 3 A A Pass 1400-2000 Back H 3 A A Pass 1400-2000 Back V 3 A A Pass 1400-2000 Left H 3 A A Pass 1400-2000 Left V 3 A A Pass 1400-2000 Right H 3 A A Pass 1400-2000 Right V 3 A A Pass 1400-2000 Top H 3 A A Pass 1400-2000 Top V 3 A A Pass 1400-2000 Down H 3 A A Pass 1400-2000 Down V 3 A A Pass
Note:
The testing performed is from lowest level up to the highest level as required by standard, but only highest level is shown on the report.
Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss/Error of function Additional Information
There was no observable degradation in performance. EUT stopped operation and could / could not be reset by operator at V/m
at frequency MHz. No false alarms or other malfunctions were observed during or after the test.
Report No. 068L169-RF-CE-P02V01
Page: 56 of 72 Version:1.0
Product : MEGA BOOK Test Item : Radiated Susceptibility Test Site : No.5 EMC fully Chamber Test Mode : Mode2: Normal Operation (Adapter 2)
Frequency (MHz)
Position (Angle)
Polarity(H or V)
Field Strength (V/m)
Required Criteria
Complied To Criteria
(A, B, C) Results
80-1000 Front H 3 A A Pass 80-1000 Front V 3 A A Pass 80-1000 Back H 3 A A Pass 80-1000 Back V 3 A A Pass 80-1000 Left H 3 A A Pass 80-1000 Left V 3 A A Pass 80-1000 Right H 3 A A Pass 80-1000 Right V 3 A A Pass 80-1000 Top H 3 A A Pass 80-1000 Top V 3 A A Pass 80-1000 Down H 3 A A Pass 80-1000 Down V 3 A A Pass
1400-2000 Front H 3 A A Pass 1400-2000 Front V 3 A A Pass 1400-2000 Back H 3 A A Pass 1400-2000 Back V 3 A A Pass 1400-2000 Left H 3 A A Pass 1400-2000 Left V 3 A A Pass 1400-2000 Right H 3 A A Pass 1400-2000 Right V 3 A A Pass 1400-2000 Top H 3 A A Pass 1400-2000 Top V 3 A A Pass 1400-2000 Down H 3 A A Pass 1400-2000 Down V 3 A A Pass
Note:
The testing performed is from lowest level up to the highest level as required by standard, but only highest level is shown on the report.
Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss/Error of function Additional Information
There was no observable degradation in performance. EUT stopped operation and could / could not be reset by operator at V/m
at frequency MHz. No false alarms or other malfunctions were observed during or after the test.
Report No. 068L169-RF-CE-P02V01
Page: 57 of 72 Version:1.0
Product : MEGA BOOK Test Item : Radiated Susceptibility Test Site : No.5 EMC fully Chamber Test Mode : Mode3: Normal Operation (Adapter 3)
Frequency (MHz)
Position (Angle)
Polarity(H or V)
Field Strength (V/m)
Required Criteria
Complied To Criteria
(A, B, C) Results
80-1000 Front H 3 A A Pass 80-1000 Front V 3 A A Pass 80-1000 Back H 3 A A Pass 80-1000 Back V 3 A A Pass 80-1000 Left H 3 A A Pass 80-1000 Left V 3 A A Pass 80-1000 Right H 3 A A Pass 80-1000 Right V 3 A A Pass 80-1000 Top H 3 A A Pass 80-1000 Top V 3 A A Pass 80-1000 Down H 3 A A Pass 80-1000 Down V 3 A A Pass
1400-2000 Front H 3 A A Pass 1400-2000 Front V 3 A A Pass 1400-2000 Back H 3 A A Pass 1400-2000 Back V 3 A A Pass 1400-2000 Left H 3 A A Pass 1400-2000 Left V 3 A A Pass 1400-2000 Right H 3 A A Pass 1400-2000 Right V 3 A A Pass 1400-2000 Top H 3 A A Pass 1400-2000 Top V 3 A A Pass 1400-2000 Down H 3 A A Pass 1400-2000 Down V 3 A A Pass
Note:
The testing performed is from lowest level up to the highest level as required by standard, but only highest level is shown on the report.
Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss/Error of function Additional Information
There was no observable degradation in performance. EUT stopped operation and could / could not be reset by operator at V/m
at frequency MHz. No false alarms or other malfunctions were observed during or after the test.
Report No. 068L169-RF-CE-P02V01
Page: 58 of 72 Version:1.0
12.6. Test Data of Electrical Fast Transient
Product : MEGA BOOK Test Item : Electrical Fast Transient Test Site : No.2 Shielded Room Test Mode : Mode1: Normal Operation (Adapter 1)
Note:
The testing performed is from lowest level up to the highest level as required by standard, but only highest level is shown on the report.
Meet criteria A : Operate as intended during and after the test Meet criteria B : Operate as intended after the test Meet criteria C : Loss/Error of function Additional Information
EUT stopped operation and could / could not be reset by operator at kV of
Line . No false alarms or other malfunctions were observed during or after the test.
Inject Line
Polarity Voltage
(kV)
Inject Time
(Second)
Inject Method
Required Criteria
Complied to Criteria Result
L + N +PE ± 1 60 Direct B A Pass
LAN ± 0.5 90 Clamp B A Pass
Telecom ± 0.5 90 Clamp B A Pass
Report No. 068L169-RF-CE-P02V01
Page: 59 of 72 Version:1.0
Product : MEGA BOOK Test Item : Electrical Fast Transient Test Site : No.2 Shielded Room Test Mode : Mode2: Normal Operation (Adapter 2)
Note:
The testing performed is from lowest level up to the highest level as required by standard, but only highest level is shown on the report.
Meet criteria A : Operate as intended during and after the test Meet criteria B : Operate as intended after the test Meet criteria C : Loss/Error of function Additional Information
EUT stopped operation and could / could not be reset by operator at kV of
Line . No false alarms or other malfunctions were observed during or after the test.
Inject Line
Polarity Voltage
(kV)
Inject Time
(Second)
Inject Method
Required Criteria
Complied to Criteria Result
L + N +PE ± 1 60 Direct B A Pass
LAN ± 0.5 90 Clamp B A Pass
Telecom ± 0.5 90 Clamp B A Pass
Report No. 068L169-RF-CE-P02V01
Page: 60 of 72 Version:1.0
Product : MEGA BOOK Test Item : Electrical Fast Transient Test Site : No.2 Shielded Room Test Mode : Mode3: Normal Operation (Adapter 3)
Note:
The testing performed is from lowest level up to the highest level as required by standard, but only highest level is shown on the report.
Meet criteria A : Operate as intended during and after the test Meet criteria B : Operate as intended after the test Meet criteria C : Loss/Error of function Additional Information
EUT stopped operation and could / could not be reset by operator at kV of
Line . No false alarms or other malfunctions were observed during or after the test.
Inject Line
Polarity Voltage
(kV)
Inject Time
(Second)
Inject Method
Required Criteria
Complied to Criteria Result
L + N +PE ± 1 60 Direct B A Pass
LAN ± 0.5 90 Clamp B A Pass
Telecom ± 0.5 90 Clamp B A Pass
Report No. 068L169-RF-CE-P02V01
Page: 61 of 72 Version:1.0
12.7. Test Data of Surge
Product : MEGA BOOK Test Item : Surge Test Site : No. 6 Shielded Room Test Mode : Mode1: Normal Operation (Adapter 1)
Inject Line
Polarity AngleVoltage
(kV)
Time Interval
(Second)
Inject Method
Required Criteria
Complied to Criteria Result
L-N ± 0 1 60 Direct B A Pass
L-N ± 90 1 60 Direct B A Pass
L-N ± 180 1 60 Direct B A Pass
L-N ± 270 1 60 Direct B A Pass
N-PE ± 0 2 60 Direct B A Pass
N-PE ± 90 2 60 Direct B A Pass
N-PE ± 180 2 60 Direct B A Pass
N-PE ± 270 2 60 Direct B A Pass
L+PE ± 0 2 60 Direct B A Pass
L+PE ± 90 2 60 Direct B A Pass
L+PE ± 180 2 60 Direct B A Pass
L+PE ± 270 2 60 Direct B A Pass
Note:
The testing performed is from lowest level up to the highest level as required by standard, but only highest level is shown on the report.
Meet criteria A : Operate as intended during and after the test Meet criteria B : Operate as intended after the test Meet criteria C : Loss/Error of function Additional Information
EUT stopped operation and could / could not be reset by operator at kV of
Line . No false alarms or other malfunctions were observed during or after the test.
Report No. 068L169-RF-CE-P02V01
Page: 62 of 72 Version:1.0
Product : MEGA BOOK Test Item : Surge Test Site : No. 6 Shielded Room Test Mode : Mode2: Normal Operation (Adapter 2)
Inject Line
Polarity AngleVoltage
(kV)
Time Interval
(Second)
Inject Method
Required Criteria
Complied to Criteria Result
L-N ± 0 1 60 Direct B A Pass
L-N ± 90 1 60 Direct B A Pass
L-N ± 180 1 60 Direct B A Pass
L-N ± 270 1 60 Direct B A Pass
N-PE ± 0 2 60 Direct B A Pass
N-PE ± 90 2 60 Direct B A Pass
N-PE ± 180 2 60 Direct B A Pass
N-PE ± 270 2 60 Direct B A Pass
L+PE ± 0 2 60 Direct B A Pass
L+PE ± 90 2 60 Direct B A Pass
L+PE ± 180 2 60 Direct B A Pass
L+PE ± 270 2 60 Direct B A Pass
Note:
The testing performed is from lowest level up to the highest level as required by standard, but only highest level is shown on the report.
Meet criteria A : Operate as intended during and after the test Meet criteria B : Operate as intended after the test Meet criteria C : Loss/Error of function Additional Information
EUT stopped operation and could / could not be reset by operator at kV of
Line . No false alarms or other malfunctions were observed during or after the test.
Report No. 068L169-RF-CE-P02V01
Page: 63 of 72 Version:1.0
Product : MEGA BOOK Test Item : Surge Test Site : No. 6 Shielded Room Test Mode : Mode3: Normal Operation (Adapter 3)
Inject Line
Polarity AngleVoltage
(kV)
Time Interval
(Second)
Inject Method
Required Criteria
Complied to Criteria Result
L-N ± 0 1 60 Direct B A Pass
L-N ± 90 1 60 Direct B A Pass
L-N ± 180 1 60 Direct B A Pass
L-N ± 270 1 60 Direct B A Pass
N-PE ± 0 2 60 Direct B A Pass
N-PE ± 90 2 60 Direct B A Pass
N-PE ± 180 2 60 Direct B A Pass
N-PE ± 270 2 60 Direct B A Pass
L+PE ± 0 2 60 Direct B A Pass
L+PE ± 90 2 60 Direct B A Pass
L+PE ± 180 2 60 Direct B A Pass
L+PE ± 270 2 60 Direct B A Pass
Note:
The testing performed is from lowest level up to the highest level as required by standard, but only highest level is shown on the report.
Meet criteria A : Operate as intended during and after the test Meet criteria B : Operate as intended after the test Meet criteria C : Loss/Error of function Additional Information
EUT stopped operation and could / could not be reset by operator at kV of
Line . No false alarms or other malfunctions were observed during or after the test.
Report No. 068L169-RF-CE-P02V01
Page: 64 of 72 Version:1.0
12.8. Test Data of Conducted Susceptibility
Product : MEGA BOOK Test Item : Conducted Susceptibility Test Site : No. 6 Shielded Room Test Mode : Mode1: Normal Operation (Adapter 1)
Frequency
Range
(MHz)
Voltage
Applied
dBuV(V)
Inject
Method
Tested Port of
EUT
Required
Criteria
Performance
Criteria
Complied To
Result
0.15~80 130(3V) CDN AC IN A A PASS
0.15~80 130(3V) CDN LAN A A PASS
0.15~80 130(3V) CDN Telecom A A PASS
Note:
The testing performed is from lowest level up to the highest level as required by standard, but only highest level is shown on the report.
Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss/Error of function Additional Information
EUT stopped operation and could / could not be reset by operator at kV of
Line . No false alarms or other malfunctions were observed during or after the test. The acceptance
criteria were met, and the EUT passed the test.
Report No. 068L169-RF-CE-P02V01
Page: 65 of 72 Version:1.0
Product : MEGA BOOK Test Item : Conducted Susceptibility Test Site : No. 6 Shielded Room Test Mode : Mode2: Normal Operation (Adapter 2)
Frequency
Range
(MHz)
Voltage
Applied
dBuV(V)
Inject
Method
Tested Port of
EUT
Required
Criteria
Performance
Criteria
Complied To
Result
0.15~80 130(3V) CDN AC IN A A PASS
0.15~80 130(3V) CDN LAN A A PASS
0.15~80 130(3V) CDN Telecom A A PASS
Note:
The testing performed is from lowest level up to the highest level as required by standard, but only highest level is shown on the report.
Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss/Error of function Additional Information
EUT stopped operation and could / could not be reset by operator at kV of
Line . No false alarms or other malfunctions were observed during or after the test. The acceptance
criteria were met, and the EUT passed the test.
Report No. 068L169-RF-CE-P02V01
Page: 66 of 72 Version:1.0
Product : MEGA BOOK Test Item : Conducted Susceptibility Test Site : No. 6 Shielded Room Test Mode : Mode3: Normal Operation (Adapter 3)
Frequency
Range
(MHz)
Voltage
Applied
dBuV(V)
Inject
Method
Tested Port of
EUT
Required
Criteria
Performance
Criteria
Complied To
Result
0.15~80 130(3V) CDN AC IN A A PASS
0.15~80 130(3V) CDN LAN A A PASS
0.15~80 130(3V) CDN Telecom A A PASS
Note:
The testing performed is from lowest level up to the highest level as required by standard, but only highest level is shown on the report.
Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss/Error of function Additional Information
EUT stopped operation and could / could not be reset by operator at kV of
Line . No false alarms or other malfunctions were observed during or after the test. The acceptance
criteria were met, and the EUT passed the test.
Report No. 068L169-RF-CE-P02V01
Page: 67 of 72 Version:1.0
12.9. Test Data of Voltage Dips and Interruption
Product : MEGA BOOK Test Item : Voltage Dips and Interruption Test Site : No.6 Shielded Room Test Mode : Mode1: Normal Operation (Adapter 1)
Voltage Dips and
Interruption Reduction (%)
Angle Test Duration
(ms)
Required Performance
Criteria
Performance Criteria Complied
To
Test Result
30 0 10 B A PASS 30 45 10 B A PASS 30 90 10 B A PASS 30 135 10 B A PASS 30 180 10 B A PASS 30 225 10 B A PASS 30 270 10 B A PASS 30 315 10 B A PASS 60 0 100 C A PASS 60 45 100 C A PASS 60 90 100 C A PASS 60 135 100 C A PASS 60 180 100 C A PASS 60 225 100 C A PASS 60 270 100 C A PASS 60 315 100 C A PASS
>95 0 5000 C A PASS >95 45 5000 C A PASS >95 90 5000 C A PASS >95 135 5000 C A PASS >95 180 5000 C A PASS >95 225 5000 C A PASS >95 270 5000 C A PASS >95 315 5000 C A PASS
Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss/Error of function Additional Information
The nominal voltage of EUT is 230V. EUT stopped operation and could / could not be reset by operator at kV of
Line . No false alarms or other malfunctions were observed during or after the test. The acceptance
criteria were met, and the EUT passed the test.
Report No. 068L169-RF-CE-P02V01
Page: 68 of 72 Version:1.0
Product : MEGA BOOK Test Item : Voltage Dips and Interruption Test Site : No.6 Shielded Room Test Mode : Mode2: Normal Operation (Adapter 2)
Voltage Dips and
Interruption Reduction (%)
Angle Test Duration
(ms)
Required Performance
Criteria
Performance Criteria Complied
To
Test Result
30 0 10 B A PASS 30 45 10 B A PASS 30 90 10 B A PASS 30 135 10 B A PASS 30 180 10 B A PASS 30 225 10 B A PASS 30 270 10 B A PASS 30 315 10 B A PASS 60 0 100 C A PASS 60 45 100 C A PASS 60 90 100 C A PASS 60 135 100 C A PASS 60 180 100 C A PASS 60 225 100 C A PASS 60 270 100 C A PASS 60 315 100 C A PASS
>95 0 5000 C A PASS >95 45 5000 C A PASS >95 90 5000 C A PASS >95 135 5000 C A PASS >95 180 5000 C A PASS >95 225 5000 C A PASS >95 270 5000 C A PASS >95 315 5000 C A PASS
Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss/Error of function Additional Information
The nominal voltage of EUT is 230V. EUT stopped operation and could / could not be reset by operator at kV of
Line . No false alarms or other malfunctions were observed during or after the test. The acceptance
criteria were met, and the EUT passed the test.
Report No. 068L169-RF-CE-P02V01
Page: 69 of 72 Version:1.0
Product : MEGA BOOK Test Item : Voltage Dips and Interruption Test Site : No.6 Shielded Room Test Mode : Mode3: Normal Operation (Adapter 3)
Voltage Dips and
Interruption Reduction (%)
Angle Test Duration
(ms)
Required Performance
Criteria
Performance Criteria Complied
To
Test Result
30 0 10 B A PASS 30 45 10 B A PASS 30 90 10 B A PASS 30 135 10 B A PASS 30 180 10 B A PASS 30 225 10 B A PASS 30 270 10 B A PASS 30 315 10 B A PASS 60 0 100 C A PASS 60 45 100 C A PASS 60 90 100 C A PASS 60 135 100 C A PASS 60 180 100 C A PASS 60 225 100 C A PASS 60 270 100 C A PASS 60 315 100 C A PASS
>95 0 5000 C A PASS >95 45 5000 C A PASS >95 90 5000 C A PASS >95 135 5000 C A PASS >95 180 5000 C A PASS >95 225 5000 C A PASS >95 270 5000 C A PASS >95 315 5000 C A PASS
Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss/Error of function Additional Information
The nominal voltage of EUT is 230V. EUT stopped operation and could / could not be reset by operator at kV of
Line . No false alarms or other malfunctions were observed during or after the test. The acceptance
criteria were met, and the EUT passed the test.
Report No. 068L169-RF-CE-P02V01
Page: 70 of 72 Version:1.0
Attachment 1: EUT Test Photographs
Report No.: 068L169-RF-CE-P02V01
Page : 1 of 22 Version:1.0
Attachment 1: EUT Test Setup Photographs
Front View of Conducted Test –Mode 1
Back View of Conducted Test-Mode 1
Report No.: 068L169-RF-CE-P02V01
Page : 2 of 22 Version:1.0
Front View of Conducted Test –Mode 2
Back View of Conducted Test-Mode 2
Report No.: 068L169-RF-CE-P02V01
Page : 3 of 22 Version:1.0
Front View of Conducted Test –Mode 3
Back View of Conducted Test-Mode 3
Report No.: 068L169-RF-CE-P02V01
Page : 4 of 22 Version:1.0
Front View of Conducted Test (ISN)
Back View of Conducted Test (ISN)
Report No.: 068L169-RF-CE-P02V01
Page : 5 of 22 Version:1.0
Front View of Conducted Test (ISN-Telecom)
Back View of Conducted Test (ISN-Telecom)
Report No.: 068L169-RF-CE-P02V01
Page : 6 of 22 Version:1.0
Front View of Radiated Test –Mode 1
Back View of Radiated Test-Clamp-Mode 1
Report No.: 068L169-RF-CE-P02V01
Page : 7 of 22 Version:1.0
Front View of Radiated Test –Mode 2
Back View of Radiated Test-Clamp-Mode 2
Report No.: 068L169-RF-CE-P02V01
Page : 8 of 22 Version:1.0
Front View of Radiated Test –Mode 3
Back View of Radiated Test-Clamp-Mode 3
Report No.: 068L169-RF-CE-P02V01
Page : 9 of 22 Version:1.0
Power Harmonics Test Setup- Mode 1
Power Harmonics Test Setup- Mode 2
Report No.: 068L169-RF-CE-P02V01
Page : 10 of 22 Version:1.0
Power Harmonics Test Setup- Mode 3
ESD Test Setup- Mode 1
Report No.: 068L169-RF-CE-P02V01
Page : 11 of 22 Version:1.0
ESD Test Setup- Mode 2
ESD Test Setup- Mode 3
Report No.: 068L169-RF-CE-P02V01
Page : 12 of 22 Version:1.0
Radiated Susceptibility Test Setup-Mode 1
Radiated Susceptibility Test Setup-Mode 2
Report No.: 068L169-RF-CE-P02V01
Page : 13 of 22 Version:1.0
Radiated Susceptibility Test Setup-Mode 3
EFT/B Test Setup-Mode 1
Report No.: 068L169-RF-CE-P02V01
Page : 14 of 22 Version:1.0
EFT/B Test Setup (Clamp)- Mode 1
EFT/B Test Setup-Mode 2
Report No.: 068L169-RF-CE-P02V01
Page : 15 of 22 Version:1.0
EFT/B Test Setup (Clamp)- Mode 2
EFT/B Test Setup-Mode 3
Report No.: 068L169-RF-CE-P02V01
Page : 16 of 22 Version:1.0
EFT/B Test Setup (Clamp)- Mode 3
SURGE Test Setup- Mode 1
Report No.: 068L169-RF-CE-P02V01
Page : 17 of 22 Version:1.0
SURGE Test Setup- Mode 2
SURGE Test Setup- Mode 3
Report No.: 068L169-RF-CE-P02V01
Page : 18 of 22 Version:1.0
Conducted Susceptibility Test Setup-Mode 1
Conducted Susceptibility Test Setup- CDN –Mode 1
Report No.: 068L169-RF-CE-P02V01
Page : 19 of 22 Version:1.0
Conducted Susceptibility Test Setup-Mode 2
Conducted Susceptibility Test Setup- CDN –Mode 2
Report No.: 068L169-RF-CE-P02V01
Page : 20 of 22 Version:1.0
Conducted Susceptibility Test Setup-Mode 3
Conducted Susceptibility Test Setup- CDN –Mode 3
Report No.: 068L169-RF-CE-P02V01
Page : 21 of 22 Version:1.0
Voltage Dips Test Setup-Mode 1
Voltage Dips Test Setup-Mode 2
Report No.: 068L169-RF-CE-P02V01
Page : 22 of 22 Version:1.0
Voltage Dips Test Setup-Mode 3
Report No. 068L169-RF-CE-P02V01
Page: 71 of 72 Version:1.0
Attachment 2: EUT Detailed Photographs
Report No.: 068L169-RF-CE-P02V01
Page : 1 of 7 Version:1.0
Attachment 2 : EUT Detailed Photographs (1) EUT Photo
(2) EUT Photo
Report No.: 068L169-RF-CE-P02V01
Page : 2 of 7 Version:1.0
(3) EUT Photo
(4) EUT Photo
Report No.: 068L169-RF-CE-P02V01
Page : 3 of 7 Version:1.0
(5) EUT Photo
(6) EUT Photo
Report No.: 068L169-RF-CE-P02V01
Page : 4 of 7 Version:1.0
(7) EUT Photo
(8) EUT Photo
Report No.: 068L169-RF-CE-P02V01
Page : 5 of 7 Version:1.0
(9) EUT Photo
(10) EUT Photo
Report No.: 068L169-RF-CE-P02V01
Page : 6 of 7 Version:1.0
(11) EUT Photo
(12) EUT Photo
Report No.: 068L169-RF-CE-P02V01
Page : 7 of 7 Version:1.0
(13) EUT Photo
(14) EUT Photo
Report No. 068L169-RF-CE-P02V01
Page: 72 of 72 Version:1.0
Reference: Laboratory of License