063_busbars for shipbuilding gb
TRANSCRIPT
-
7/30/2019 063_Busbars for Shipbuilding GB
1/13
Automation and Drives
reakthe Limits!
Low-Voltage Controls and Distribution
-
7/30/2019 063_Busbars for Shipbuilding GB
2/13
Automation and Drives
Low-Voltage
Controls& Distribution
Low-Voltage Controlsand Distribution Siemens Your qualified partner for busbar-trunking systems in
shipbuilding
Experience in ship building since 1993
Busbar range from 25A to 2700A
approved by:
DNV Det Norske Veritas
LRS Lloyds Register of Shipping
in preparation:
GL Germanischer Lloyd
BV Bureau Veritas
Busbar-trunking systems for Shipbuilding
-
7/30/2019 063_Busbars for Shipbuilding GB
3/13
Automation and Drives
Low-Voltage
Controls& Distribution
Low-Voltage Controlsand Distribution Advantages of innovative busbar-trunking systems compared to
conventional cable installation
Space saving compact design of the busbar-system
Modular - the modular concept of a busbar-trunking-system allows very short installation times and
supports segmential installation. Immediately afterthe installation the busbar-trunking system can beused to distribute energy on the construction side.
Flexibility in changings: tap-off boxes can be placedand removed while the system is live.
Fire load - enclosures made of sheet metal and mainlymetallic material inside a busbar-trunking unit the
fire load is strongly reduced in comparison to cableinstallation
High short circuit rating as it is required for anelectrical installation in a ship.
Busbar-trunking systems for Shipbuilding
-
7/30/2019 063_Busbars for Shipbuilding GB
4/13
Automation and Drives
Low-Voltage
Controls& Distribution
Low-Voltage Controlsand Distribution
Siemens Busbar-trunking systems for energy distribution inships
- System BD01
Application:
Power supply for cabins in each deck
Current rating busbar: 32 - 130 A
Current rating tap-off box: 13 - 50 A
At 45C ambient temperature
Protection degree IP54/IP55
3 or 6 tap-off points on a 3m trunking-unitlength
Busbar-trunking systems for Shipbuilding
-
7/30/2019 063_Busbars for Shipbuilding GB
5/13
Automation and Drives
Low-Voltage
Controls& Distribution
Low-Voltage Controlsand Distribution
Application:
Riser for energy supply for the decks
Current rating busbar : 150 - 950 A
Current rating tap-off box : 15 - 415 A
At 45C ambient temperature
Protection degree IP54/IP55
12 tap-off-points on a 3,25m trunking-unit length
Siemens Busbar-trunking systems for energy distribution inships
- System BD2
Busbar-trunking systems for Shipbuilding
-
7/30/2019 063_Busbars for Shipbuilding GB
6/13
Automation and Drives
Low-Voltage
Controls& Distribution
Low-Voltage Controlsand Distribution
Application:
Energy transport between main- and submainboardsfor the main energy supply
Current rating busbar : 850 2700A
Current rating tap-off box : 95 - 540A
At 45C ambient temperature
Protection degree IP54/56
3 tap-off-points on a 3m trunking-unit length
Siemens Busbar-trunking systems for energy distribution inships
- System LD
Busbar-trunking systems for Shipbuilding
-
7/30/2019 063_Busbars for Shipbuilding GB
7/13
Automation and Drives
Low-Voltage
Controls& Distribution
Low-Voltage Controlsand Distribution
Special solutions
- Bulkhead A60
Bulkheads for A60-decks for BD2- andLD-System
To realise a continious installation of thebusbar system through an A60-deck there is
a fire- and water resistant bulkheadnecessary
The internal bulkhead is delivered ex factory.
The outside part of bulkhead is realised onsite in a steel pipe using Flammadur E950
sealing compound.
Busbar-trunking systems for Shipbuilding
-
7/30/2019 063_Busbars for Shipbuilding GB
8/13
Automation and Drives
Low-Voltage
Controls& Distribution
Low-Voltage Controlsand Distribution
Special solutions
- Fixing brackets
Special brackets for space savinginstallation
BD01 BD2 LD
Busbar-trunking systems for Shipbuilding
-
7/30/2019 063_Busbars for Shipbuilding GB
9/13
Automation and Drives
Low-Voltage
Controls& Distribution
Low-Voltage Controlsand Distribution
Special solutions
- Busbar trunking-units and tap-off boxes
Tap-off boxes and trunking-units:
CD-System: Special fixing brackets
BD01-System: Very compact and smalltap-off units designed for the
interspace in the ceiling
BD2-System: Tap-off boxes with severalMCCB inside space-saving
Extremly small feeder units enable an
installation in areas where a verylimited space is required
LD-System: Busbar trunking with adouble-hook for easy installation
under limited space requirements
BD01
BD2
LD
CD
Busbar-trunking systems for Shipbuilding
-
7/30/2019 063_Busbars for Shipbuilding GB
10/13
Automation and Drives
Low-Voltage
Controls& Distribution
Low-Voltage Controlsand Distribution
Special solutions
- Tap-off boxes
Compact tap-off boxes allowing a ship specificspace-saving installation
Asymmetrical mounting possible
Cable-entry from backside (trunking-side)
Several MCCBs in one tap-off unit
Compact sizes of the housing
Busbar-trunking systems for Shipbuilding
-
7/30/2019 063_Busbars for Shipbuilding GB
11/13
Automation and Drives
Low-Voltage
Controls& Distribution
Low-Voltage Controlsand Distribution
Queen Mary 2
Chantiers de l'Atlantique (Alstom Marine)
Applications and references
Busbar-trunking systems for Shipbuilding
-
7/30/2019 063_Busbars for Shipbuilding GB
12/13
Automation and Drives
Low-Voltage
Controls& Distribution
Low-Voltage Controlsand Distribution
Norwegian Sun
Pride of America
Applications and references
Busbar-trunking systems for Shipbuilding
-
7/30/2019 063_Busbars for Shipbuilding GB
13/13
Automation and Drives
Low-Voltage
Controls& Distribution
Low-Voltage Controlsand Distribution
Pont Aven
Container-Ships
Applications and references
Cruise ship, Italy