RNC Software Maintenance
8/18/2019 06 01 Rn33156en10gla0 Rnc Sw Maintenance
http://slidepdf.com/reader/full/06-01-rn33156en10gla0-rnc-sw-maintenance 2/35
2 © Noki a Si emens Net works Present ati on / Aut hor / Date / Doc ument Number
For public use – IPR applies
Nokia Siemens Networks Academy
Legal notice
Intellectual Property Rights
All copyrights and intellectual property rights for Nokia Siemens Networks training documentation,product documentation and slide presentation material, all of which are forthwith known as NokiaSiemens Networks training material, are the exclusive property of Nokia Siemens Networks. NokiaSiemens Networks owns the rights to copying, modification, translation, adaptation or derivativesincluding any improvements or developments. Nokia Siemens Networks has the sole right to copy,distribute, amend, modify, develop, license, sublicense, sell, transfer and assign the Nokia SiemensNetworks training material. Individuals can use the Nokia Siemens Networks training material for theirown personal self-development only, those same individuals cannot subsequently pass on that sameIntellectual Property to others without the prior written agreement of Nokia Siemens Networks. TheNokia Siemens Networks training material cannot be used outside of an agreed Nokia SiemensNetworks training session for development of groups without the prior written agreement of NokiaSiemens Networks.
8/18/2019 06 01 Rn33156en10gla0 Rnc Sw Maintenance
http://slidepdf.com/reader/full/06-01-rn33156en10gla0-rnc-sw-maintenance 3/35
4 © Noki a Si emens Net works Present ati on / Aut hor / Date / Doc ument Number
For public use – IPR applies
Content
• CD Installation
• SW upgrade
• Rollback
8/18/2019 06 01 Rn33156en10gla0 Rnc Sw Maintenance
http://slidepdf.com/reader/full/06-01-rn33156en10gla0-rnc-sw-maintenance 4/35
5 © Noki a Si emens Net works Present ati on / Aut hor / Date / Doc ument Number
For public use – IPR applies
CD Installation
CD Installation may add one or more of the following tasks:
• HMS Upgrade
• Boot Upgrade
• Conversions
• Multiple CD installation
8/18/2019 06 01 Rn33156en10gla0 Rnc Sw Maintenance
http://slidepdf.com/reader/full/06-01-rn33156en10gla0-rnc-sw-maintenance 5/35
6 © Noki a Si emens Net works Present ati on / Aut hor / Date / Doc ument Number
For public use – IPR applies
CD Installation Procedures
1. Preparations
2. Transferring software into RNC
3. File conversions
4. CD installation
5. Activation new package
8/18/2019 06 01 Rn33156en10gla0 Rnc Sw Maintenance
http://slidepdf.com/reader/full/06-01-rn33156en10gla0-rnc-sw-maintenance 6/35
7 © Noki a Si emens Net works Present ati on / Aut hor / Date / Doc ument Number
For public use – IPR applies
Preparation
Check pre-requiredsoftware
Make safecopy of active
package
Record RNC
configuration
Check pre-conditions
//run PRECHECKRNC.TEL
//delete non-default package
//create CDTEMP directory
8/18/2019 06 01 Rn33156en10gla0 Rnc Sw Maintenance
http://slidepdf.com/reader/full/06-01-rn33156en10gla0-rnc-sw-maintenance 7/35
8 © Noki a Si emens Net works Present ati on / Aut hor / Date / Doc ument Number
For public use – IPR applies
Transferring Software into RNC
Download CD from NOLS
Copy CD from NetAct to RNC
Check CDTEMP directory
//IXX
//IXX
//MAS:XV
8/18/2019 06 01 Rn33156en10gla0 Rnc Sw Maintenance
http://slidepdf.com/reader/full/06-01-rn33156en10gla0-rnc-sw-maintenance 8/35
9 © Noki a Si emens Net works Present ati on / Aut hor / Date / Doc ument Number
For public use – IPR applies
File Conversion
Copy needed files to
TMPDIR and CONVPR
Copy memory files to
disk
Check integrity&
Safecopy database
Run database and file
conversions
Copy converted files to
CDTEMP
8/18/2019 06 01 Rn33156en10gla0 Rnc Sw Maintenance
http://slidepdf.com/reader/full/06-01-rn33156en10gla0-rnc-sw-maintenance 9/35
10 ©Nokia Siemens Networks Presentat ion / Author / Date / Document Number
For public use – IPR applies
CD Installation
Add CD to active
package
Create new package
Activate new package
Upgrade Boot proms
Check package
consistency
8/18/2019 06 01 Rn33156en10gla0 Rnc Sw Maintenance
http://slidepdf.com/reader/full/06-01-rn33156en10gla0-rnc-sw-maintenance 10/35
11 ©Nokia Siemens Networks Presentat ion / Author / Date / Document Number
For public use – IPR applies
Activate New Package
Activate new softwarepackage
Verify new package and
check database
Record RNC configuration
//WQC
//run PRECHECKRNC.TEL
//USS
HMS Upgrade
8/18/2019 06 01 Rn33156en10gla0 Rnc Sw Maintenance
http://slidepdf.com/reader/full/06-01-rn33156en10gla0-rnc-sw-maintenance 11/35
12 ©Nokia Siemens Networks Presentat ion / Author / Date / Document Number
For public use – IPR applies
HMS Software Update Procedure
1. Preparation
2. Update HMS Nodes
3. Troubleshooting
8/18/2019 06 01 Rn33156en10gla0 Rnc Sw Maintenance
http://slidepdf.com/reader/full/06-01-rn33156en10gla0-rnc-sw-maintenance 12/35
13 ©Nokia Siemens Networks Presentat ion / Author / Date / Document Number
For public use – IPR applies
Preparation (1/2)
Every criterion must be fulfilled
• OMU-1 must be in use (SP-EX, WO-EX)
• Perform updating during low traffic periods
• Remote update is not supported
• During updating the unit’s recovery functions are disabled
• PIUs must be in SE-NH, SP-EX or WO-EX and no faulty flag in anyunit
• While updating HMS slave and bridge RSMU, RRMU and OMUspare must be inSE-NH
• Do not detach the updating unit or turn its power off • Slave updating can be performed with a command for either all
units in subrack or each unit one by one
8/18/2019 06 01 Rn33156en10gla0 Rnc Sw Maintenance
http://slidepdf.com/reader/full/06-01-rn33156en10gla0-rnc-sw-maintenance 13/35
14 ©Nokia Siemens Networks Presentat ion / Author / Date / Document Number
For public use – IPR applies
Preparation (2/2)
• No HMS services during the updating HMS bridge subrack
• Use HMEXTE service terminal extension to update&check HMSslave/bridge/master code versions Check alarm history related HWalarms (AAP,UDU)
• Check Flash programmer ’s version before HMS update
• Check variants of HMS node
• Check HMS code version
• Do not continue if problems occur during the update. Stop andrepair problem before continuing
• Updating order is Slave nodes, Bridge nodes, and Masternodes.
8/18/2019 06 01 Rn33156en10gla0 Rnc Sw Maintenance
http://slidepdf.com/reader/full/06-01-rn33156en10gla0-rnc-sw-maintenance 14/35
15 ©Nokia Siemens Networks Presentat ion / Author / Date / Document Number
For public use – IPR applies
Check HMS Flash Programmer
Block alarms and change
RSMU OMU state
Check Slave nodes
Unblock alarms and change
RSMU, OMU state
Enable switchover and clear
FBAN
Check Master nodesCheck Bridge nodes
Set FBAN flags for all units
8/18/2019 06 01 Rn33156en10gla0 Rnc Sw Maintenance
http://slidepdf.com/reader/full/06-01-rn33156en10gla0-rnc-sw-maintenance 15/35
16 ©Nokia Siemens Networks Presentat ion / Author / Date / Document Number
For public use – IPR applies
Check HMS Code Version
Check Master’s code version
Check Bridge’s code version
Check Slave’s code version
//HCI →address of the local HMS master node
//HCO:0,0,0 and HCO:0,0,1
//HFB, HCM, HCO, HFD, HFC
//HCO:c,s,ppa
8/18/2019 06 01 Rn33156en10gla0 Rnc Sw Maintenance
http://slidepdf.com/reader/full/06-01-rn33156en10gla0-rnc-sw-maintenance 16/35
17 ©Nokia Siemens Networks Presentat ion / Author / Date / Document Number
For public use – IPR applies
HMS Updating Sequence
Update HMS-slave
Update HMS-bridge
Update HMS-master
8/18/2019 06 01 Rn33156en10gla0 Rnc Sw Maintenance
http://slidepdf.com/reader/full/06-01-rn33156en10gla0-rnc-sw-maintenance 17/35
18 ©Nokia Siemens Networks Presentat ion / Author / Date / Document Number
For public use – IPR applies
Updating HMS Slave Node
Set FBAN flags and block
alarms
Update HMS-slave code in all
PIUs in the subrack
Update HMS-slave code in
one PIU in the subrack
Enable switchovers and clear
FBAN flags
//FA:<rack>,<subrack>,<ppa>::<directory/file_name>,
<file_type>
//AFB,AFP
//JT:ALL,,,S,FBAN
//FB//DP
//FA:<rack>,<subrack>,3C::<directory/file_name>,
<file_type>
//CM
//TBU
//FD
//FC
//JT:ALL,,,C,FBAN
//AFU
//AFP
//DP
8/18/2019 06 01 Rn33156en10gla0 Rnc Sw Maintenance
http://slidepdf.com/reader/full/06-01-rn33156en10gla0-rnc-sw-maintenance 18/35
19 ©Nokia Siemens Networks Presentat ion / Author / Date / Document Number
For public use – IPR applies
Updating HMS Bridge Node
Set FBAN flags and blockalarms
Update HMS-bridge code in all
TSS3 and TBUF
Enable switchovers and clear
FBAN flags
//AFB,AFP//JT:ALL,,,S,FBAN
//FB
//CM
//DP
//FA:<rack>,<subrack>,<ppa>::<directory/file_name>,
<file_type> ; <ppa> line00=3D, line01=3E
//DP
//FD
//CM
//TBU
//FD
//FC//JT:ALL,,,C,FBAN
//AFU
//AFP
//DP
8/18/2019 06 01 Rn33156en10gla0 Rnc Sw Maintenance
http://slidepdf.com/reader/full/06-01-rn33156en10gla0-rnc-sw-maintenance 19/35
20 ©Nokia Siemens Networks Presentat ion / Author / Date / Document Number
For public use – IPR applies
Updating HMS Master Node
Set FBAN flags and block
alarms
Update HMS-bridge code in all
TSS3 and TBUF
Enable switchovers and clear
FBAN flags
//AFB,AFP
//FB
//JT:ALL,,,S,RBAN
//JT:ALL,,,C,FBAN
//FA:0,0,2::WO-/<directory/file_name>,<file_type>
//CM
//TBU
//FD
//FC
//FB
//CM
//TBU
//FD
//FC//JT:ALL,,,C,RBAN
//AFU
//AFP
//DP
8/18/2019 06 01 Rn33156en10gla0 Rnc Sw Maintenance
http://slidepdf.com/reader/full/06-01-rn33156en10gla0-rnc-sw-maintenance 20/35
21 ©Nokia Siemens Networks Presentat ion / Author / Date / Document Number
For public use – IPR applies
RNC SW Upgrade
1. Preparation
2. Safecopying The Current Package
3. Copying The New Software
4. Checking Precondition
5. Running The Upgrade Macro
6. Checking The System Configuration
7. Updating HMS SW (see previous topic)
8/18/2019 06 01 Rn33156en10gla0 Rnc Sw Maintenance
http://slidepdf.com/reader/full/06-01-rn33156en10gla0-rnc-sw-maintenance 21/35
22 ©Nokia Siemens Networks Presentat ion / Author / Date / Document Number
For public use – IPR applies
Preparation
• Checking Prerequisites – General
▪ RNC user account with full MML command authority (250)
▪ Telnet connection to the RNC
▪ General compatibility requirement (see SW Compatibility RN4.0)
▪ PC with HIT v2.8.0 or later
▪ Unit has to be either WO-EX, SP-EX or SE-NH
▪ No FLTY flag on any unit or sub-unit
▪ Enough free disk space for the new RN4.0 SW (about 1 000 000 BLOCK)Check with ZI WX: : WS, NODEF: : %, DI R, ;
– SW and Instruction
▪ RN4.0 Software Package
▪ Software Upgrade RN4.0
▪ RN4.0 CD0.0 Installation Instruction
▪ Boot and HMS Software Version for Q4 1.11-0
▪ Nokia Siemens Networks WCDMA RAN, Rel. RU10, System Library (NED)
8/18/2019 06 01 Rn33156en10gla0 Rnc Sw Maintenance
http://slidepdf.com/reader/full/06-01-rn33156en10gla0-rnc-sw-maintenance 22/35
23 ©Nokia Siemens Networks Presentat ion / Author / Date / Document Number
For public use – IPR applies
Preparation – Supported Path
RN2.2RN2.2
RN3.0 + CD0.0RN3.0 + CD0.0
RN4.0 + CD0.0RN4.0 + CD0.0
CD1.0CD1.0
CD1.xCD1.x
CD2.0CD2.0
CD2.xCD2.x
trial & pilotCDs
RN4.0 release supports upgrade from RN3.0 release at any CD level. To
upgrade from RN2.2 release, the RNC must be upgraded to RN3.0 release first.
8/18/2019 06 01 Rn33156en10gla0 Rnc Sw Maintenance
http://slidepdf.com/reader/full/06-01-rn33156en10gla0-rnc-sw-maintenance 23/35
24 ©Nokia Siemens Networks Presentat ion / Author / Date / Document Number
For public use – IPR applies
Preparation – Boot Compatibility
• RNC boot proms are NOT onwards compatible.
• At other hand, RNC boot proms are backward compatible.
• When RN3.0 SW is active, the required RN4.0 level boot promsneed to be burned first before the activation of RN4.0 SW package.
• Check required RN4.0 level boot proms from Boot and HMSSoftware Version for Q4 1.11-0 document
8/18/2019 06 01 Rn33156en10gla0 Rnc Sw Maintenance
http://slidepdf.com/reader/full/06-01-rn33156en10gla0-rnc-sw-maintenance 24/35
25 ©Nokia Siemens Networks Presentat ion / Author / Date / Document Number
For public use – IPR applies
Safecopying The Current Package (1/2)
•Check the status of the current running software package
– ZWQO:CR;
•If the status is NW change it to BU
– ZWSC:STAT=NW:STAT=BU;
•If the status is FB change it to NW
– ZWSR;
•Verify the current software package
– ZWQB:NAME=<active_package_name>:FORM=FAILED;
•Make a safecopy of the current running package
– ZWKS:NAME=<fallback_package_name>,DIRE=<fallback_package_dir>,MODE=FULL;
8/18/2019 06 01 Rn33156en10gla0 Rnc Sw Maintenance
http://slidepdf.com/reader/full/06-01-rn33156en10gla0-rnc-sw-maintenance 25/35
8/18/2019 06 01 Rn33156en10gla0 Rnc Sw Maintenance
http://slidepdf.com/reader/full/06-01-rn33156en10gla0-rnc-sw-maintenance 26/35
27 ©Nokia Siemens Networks Presentat ion / Author / Date / Document Number
For public use – IPR applies
Copying The New Software (1/2)
To copy the software from your PC (local/remote) to the RNC:
1. Transfer the compressed packages to the RNC with a File
Transfer Protocol (FTP) application.
2. Copy the compressed package to the /shadows/ directory of the
RNC.
– Q4011100_1.ZIP
– Q4011100_2.ZIP
– Q4011100_3.ZIP
3. Copy the Change Delivery to the / shadows/ directory of the
RNC.
– R400000N.ZIP
8/18/2019 06 01 Rn33156en10gla0 Rnc Sw Maintenance
http://slidepdf.com/reader/full/06-01-rn33156en10gla0-rnc-sw-maintenance 27/35
28 ©Nokia Siemens Networks Presentat ion / Author / Date / Document Number
For public use – IPR applies
Copying The New Software (2/2)
To copy the software from NetAct to the RNC:
1. Transfer the compressed packages to the NetAct with an FTP application.
2. Import the compressed SW package files to the NetAct archive:
a. In the Top-level User Interface window, select Utils → Software Configuration Mgmt → NE
Software Configuration Mgmt.
b. In the NE Software Configuration Manager window:
c. Select Software Archive → RNC Software Packages
d. Select where compressed SW package files are stored.
e. Select → Import.
f. Select ZIP files and give the archive directory a name.
3. Download the compressed SW package files to the RNC:
a. In the NE Software Configuration Manager window, select Software Archive → RNC
Software Packages.b. Select the Archive Directory.
c. In the NE Software Configuration Manager window, select Managed Objects → RNC (where
to download)→ Download.
8/18/2019 06 01 Rn33156en10gla0 Rnc Sw Maintenance
http://slidepdf.com/reader/full/06-01-rn33156en10gla0-rnc-sw-maintenance 28/35
29 ©Nokia Siemens Networks Presentat ion / Author / Date / Document Number
For public use – IPR applies
Checking PreconditionSaving configuration from the running package
• Open HIT and load RNC_configuration_check.tel macro
– If necessary create a new connection in HIT
Device Set Configuration New Telnet
fill in a name and the RNC IP address. If necessary select the Login tab and set theRNC user name and password
• Start the macro by clicking on the Play icon and fill in a name forthe log file that will be created in the same directory as the macrowas stored.
8/18/2019 06 01 Rn33156en10gla0 Rnc Sw Maintenance
http://slidepdf.com/reader/full/06-01-rn33156en10gla0-rnc-sw-maintenance 29/35
30 ©Nokia Siemens Networks Presentat ion / Author / Date / Document Number
For public use – IPR applies
Checking PreconditionChecking and releasing locked files
• Check that there are no locked files
ZIWX::WS,DEF:LFILES,:%,%,;
• Check the HIT log. An L in the ATTR column will next to a fileinformation will indicate that a file is locked
• Release any locked files that are found
ZIWS::<disk>,DEF:LFILES:<file_name>,<ext>,,R,L;
8/18/2019 06 01 Rn33156en10gla0 Rnc Sw Maintenance
http://slidepdf.com/reader/full/06-01-rn33156en10gla0-rnc-sw-maintenance 30/35
31 ©Nokia Siemens Networks Presentat ion / Author / Date / Document Number
For public use – IPR applies
Checking PreconditionChecking all active alarms and stopping command calendar jobs
• Printout and save all active alarmsZAAP;
• This step may have done during the execution ofRNC_configuration_check.tel macro.
• Examine alarms, try to remove alarms by carrying outmaintenance actions.
• Check that there are no command calendar jobs activeZICL;
• If any command calendar jobs are active then make a note of
them so that they can be restored after the upgrade and deletethe tasksZICD:<task_identifier>;
8/18/2019 06 01 Rn33156en10gla0 Rnc Sw Maintenance
http://slidepdf.com/reader/full/06-01-rn33156en10gla0-rnc-sw-maintenance 31/35
32 ©Nokia Siemens Networks Presentat ion / Author / Date / Document Number
For public use – IPR applies
Checking PreconditionStopping NE and RNW measurements
• Stop NE measurement by following command
– ZT2E:NAME=<measurement_identifier>:; stop measurement
– ZT2E:NAME= to see list of measurements
– ZT2I; check measurement parameters for recreation later
• Stop RNW measurement by RNW measurement management application.
8/18/2019 06 01 Rn33156en10gla0 Rnc Sw Maintenance
http://slidepdf.com/reader/full/06-01-rn33156en10gla0-rnc-sw-maintenance 32/35
8/18/2019 06 01 Rn33156en10gla0 Rnc Sw Maintenance
http://slidepdf.com/reader/full/06-01-rn33156en10gla0-rnc-sw-maintenance 33/35
34 ©Nokia Siemens Networks Presentat ion / Author / Date / Document Number
For public use – IPR applies
Running The Upgrade Macro (2/2)
– Updating boot proms
– Copying FIFILE
– Copying License files
– Activate the new SW package
– Change the new SW package status to BU
– Deleting temporary files and directories
– Safecopying the new SW package
8/18/2019 06 01 Rn33156en10gla0 Rnc Sw Maintenance
http://slidepdf.com/reader/full/06-01-rn33156en10gla0-rnc-sw-maintenance 34/35
35 ©Nokia Siemens Networks Presentat ion / Author / Date / Document Number
For public use – IPR applies
Checking The System Configuration
To check the system configuration:
1. After the upgrade macro execution, run theRNC_configuration_check.tel macro again to collect up-to-dateinformation about the system.
2. When the macro has finished, compare the two log files: the onegenerated before the upgrade, and the one generated after theupgrade.
8/18/2019 06 01 Rn33156en10gla0 Rnc Sw Maintenance
http://slidepdf.com/reader/full/06-01-rn33156en10gla0-rnc-sw-maintenance 35/35
36 ©Nokia Siemens Networks Presentat ion / Author / Date / Document Number
For public use – IPR applies
Rollback
• Rollback means activate the RN3.0 back again.
• Only possible before any HW changing takes place (includingreconfiguration RRMU to ICSU)
• Select RN3.0 SW package as default package
ZWSD:NAME=<RN3.0 package name>:;