OVERHEAD ELECTRICAL ALUMINUM CONDUCTORS Taihan Electric Wire opening up the happier world and more enriched future

Upload: gunji-venkata-srinivasa-babu

Post on 13-Apr-2015

85 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 0512 AL Conductor

OVERHEAD ELECTRICAL

ALUMINUM CONDUCTORS

Taihan Electric Wire opening up the happier world and more enriched future

Page 2: 0512 AL Conductor

CC OO NN TT EE NN TT SS

OVERHEAD ELECTRICAL

ALUMINUM CONDUCTORS

Description of A.C.S.R

Typical Construction for A.C.S.R.

KS JIS KEPCO TEC

ASTM ANSI

IEC

BS AS CSA DIN

Packing and Marking

Alphabetical List

3

4

5

21

41

47

58

61

HAL, AAC, ACSR, TACSR, ACSR/AW, AWS, STACIR,

STACIR/AW,HSTACIR/AW, TACSR/AW, HTACSR/AW,

HAL-OC, ACSR-OC, ACSR/AW-OC

HAL, AAC, ACSR, ACSR/AW, AWS, AL-ALLOY, AAAC,

H.S-ACSR, HAL-OC, ACSR-OC

AAC, ACSR, ACSR/GZ, ACSR/AZ

AAC, AAAC, ACSR, AACSR/EST

2 Overhead Electrical Aluminum Conductors TAIHAN

Page 3: 0512 AL Conductor

Description of A.C.S.R.Bare aluminum conductors, especially in the form of Aluminum Conductors Steel Reinforced(ACSR), have been widely used for

overhead transmission lines as the most cost-effective and dependable product.

As the name implies, ACSR is a concentrically stranded conductor composed of one or more layers of hard-drawn EC grade

aluminum wires over a high strength coated steel core. The core may be single wire or stranded, depending on the size. Because

of the numerous stranding combinations of aluminum and steel wires that may be used, it is possible to vary the portions of

aluminum and steel so as to obtain the most suitable relation between current carrying capacity and mechanical strength for each

application.

For instance, a conductor having a small proportion of steel may be most economical for a wood pole line to transmit a large block

of power whereas a conductor with a very large proportion of steel would be required for a long span crossing over water. Between

these two extremes are the conductors with normal proportions of aluminum and steel generally used for the more conventional

transmission and distribution lines.

Anti-corrosion A.C.S.R. Anti-corrosion ACSR is used in the corrosive areas like coastal areas or industrial zones. This ACSR is filledwith anti-corrosive grease applied on the gaps between stranded wires and their external surfaces.

Generally, anti-corrosion ACSR is divided into three types according to the method of greases coating :Light Anti-corrosion Type : Only steel wires are coated

Medium Anti-corrosion Type : All the inner layers are coated

Heavy Anti-corrosion Type : All the inner and outer layers are coated

Light Anti-corrosion Type(ACSR-LZ)

Grease

Medium Anti-corrosion Type(ACSR-MZ)

Grease

Heavy Anti-corrosion Type(ACSR-HZ)

Grease

3TAIHAN Overhead Electrical Aluminum Conductors

Page 4: 0512 AL Conductor

Smooth Body 3 Al./ 4 St. 4 Al./ 3 St. 6 Al./ 1 St.Smooth Body

6 Al./ 7 St. 8 Al./ 7 St. 12 Al./ 7 St. 7 Al./ 1 St.8 Al./ 1 St.

16 Al./ 19 St. 18 Al./ 19 St. 21 Al./ 37 St. 18 Al./ 1 St.15 Al./ 19 St.

26 Al./ 7 St. 26 Al./ 19 St. 30 Al./ 7 St. 30 Al./ 19 St.24 Al./ 7 St.

42 Al./ 19 St. 54 Al./ 7 St. 54 Al./ 19 St.34 Al./ 19 St.

Typical Construction for A.C.S.R.

4 Overhead Electrical Aluminum Conductors TAIHAN

Page 5: 0512 AL Conductor

O V E R H E A D E L E C T R I C A L A L U M I N U M C O N D U C T O R S

Korean Industrial Standards

Japanese Industrial Standards

Korea Electric Power Corp. Standard

Taihan Standard

KS

JIS

KEPCO

TEC

5TAIHAN Overhead Electrical Aluminum Conductors

TAIHAN Aluminum Clad Steel Wire offers excellentperformance and advantages with improved techniques,especially in the higher grade aluminum conductorswhich are also reasonable in price

TAIHAN Aluminum Clad Steel Wire offers excellentperformance and advantages with improved techniques,especially in the higher grade aluminum conductorswhich are also reasonable in price

Page 6: 0512 AL Conductor

These sizes are specified in KS.

Hard-drawn Aluminum Wires for Electric Purposes

ApplicationThis standard covers hard-drawn circular aluminum wires for electricpurposes to be used mainly as component wires of hard-drawnaluminum stranded cables and aluminum cables steel reinforced.

ConstructionSingle aluminum conductor

StandardsConforms to KS C 3111, JIS C 3108

HAL

Diameter Toleranceon Dia.

Tensile Strength(kgf/mm2)

Min. (%) (%) (mm2) (kg/km) ( /km, 20 )Mean

(above)

Elongation(in 250mm)

(above)

Conductivity(above) Cross

SectionalArea

Weight

Min.Mean

(above)

Tensile Load (kgf)

ElectricResistance

Reference

(mm) (mm)

1.61.82.02.32.62.82.93.13.23.53.73.84.04.24.54.85.0

0.030.030.030.030.030.030.030.030.040.040.040.040.040.040.040.040.04

19.018.618.617.917.216.916.916.516.516.516.516.516.216.216.216.216.2

20.019.719.719.018.317.917.917.617.617.617.217.216.916.916.916.916.9

1.31.41.41.51.51.61.61.71.71.71.81.81.92.02.02.02.0

6161616161616161616161616161616161

2.0112.5453.1424.1555.309 6.1586.6057.5488.0429.621

10.7511.3412.5713.8515.9018.1019.64

5.4306.8728.483

11.2214.3316.6317.8320.3821.7125.9829.0330.6233.9437.4042.9348.8753.03

38.247.358.474.491.3

104112125133159177187204224258293318

40.250.161.978.997.2

110118133142169185195212234269306332

14.111.1

9.006.805.324.594.283.743.512.942.632.492.252.041.781.561.44

(Table 1)

6 Overhead Electrical Aluminum Conductors TAIHAN

Page 7: 0512 AL Conductor

Stranded Hard-drawn Aluminum ConductorAAC

ASTM

ANSI

IEC

BSAS

CSA

DIN

ApplicationThis standard covers stranded hard-drawn aluminum conductors to beused mainly for overhead distribution wire, overhead feeders andbuses.

ConstructionStranded hard-drawn aluminum conductors

StandardsConforms to KS C 3112, JIS C 3109

These sizes are specified in KS.

NominalCross

SectionalArea

No. andDia. ofStrands

TensileLoad

(above)Calculated

CrossSectional Area

OutsideDia.

Weight ElectricResistance

Hard-drawnCopper

Equiv. Area

StandardLength

Reference

(mm) (mm) (kgf) (mm2) (mm) (kg/km) ( /km, 20 ) (mm2) (m)

22303845557595

100125150200200240250300325400460500510590660725770850880980

1,0001,260

7/2.07/2.37/2.67/2.97/3.27/3.77/4.2

19/2.619/2.919/3.219/3.737/2.619/4.037/2.937/3.261/2.637/3.737/4.061/3.237/4.261/3.561/3.791/3.261/4.061/4.291/3.591/3.7

127/3.291/4.2

369469576699838

1,1201,4101,5601,9002,2703,0303,0503,4903,7004,4305,0205,8906,7607,3007,4608,7309,720

10,89011,14012,30013,02014,50015,20018,350

21.9929.0937.1646.2456.2975.2596.95

100.9125.5152.8204.3196.4238.8244.4297.6323.8397.8465.1490.6512.5586.9655.8731.8766.8844.9875.5978.3

1,0211,260

6.06.97.88.79.6

11.112.613.014.516.018.518.220.020.322.423.425.928.028.829.431.533.335.236.037.838.540.741.646.2

60.0979.40

101.5126.3153.8205.6264.9276.4343.9418.7559.8541.3654.5673.6820.1894.2

1,0971,2821,3551,4131,6211,8122,0272,1182,3342,4262,7162,8403,499

1.3010.9840.7690.6190.5070.3800.2950.2840.2290.1880.1400.1470.1200.1180.09690.08920.07260.06210.05890.05630.04930.04410.03960.03770.03420.03310.02970.02850.0230

1418232935 4760637996

128124150154187204250292309322369412460482531551615642792

2,0001,8001,8001,0001,0001,9001,0002,4002,0001,5001,3002,4001,3002,0001,5001,2001,3001,000

8001,3001,3501,300

8001,0001,300

700600800600

(Table 2)

KSJI

SKE

PCO

TEC

7TAIHAN Overhead Electrical Aluminum Conductors

Page 8: 0512 AL Conductor

ApplicationThis standard covers aluminum stranded conductors steel reinforcedwhich could withstand high tensile load to be used mainly for overheadtransmission lines, overhead distribution lines.

ConstructionThe center wire or wires are of galvanized steel and the outer layer orlayers of aluminum.

StandardsConforms to KS C 3113, JIS C 3110

These sizes are specified in KS.

NominalCross

SectionalArea

No. and Dia. of Strands

(No./mm)

TensileLoad

(above)

( /km, 20 ) (mm2) (m)(kgf)

Calculated CrossSectional Area

(mm2)

Outside Dia.

(mm)

Weight ElectricResistance

Hard-drawnCopper

Equiv. Area

StandardLength

Reference

(mm2) Al Al AlSt St St (kg/km)

1215192532384048505864657579809597

110120120140160170200210240250280290290320330330360380

6/1.66/1.86/2.06/2.36/2.6

12/2.06/2.96/3.2

12/2.36/3.5

12/2.66/3.76/4.0

12/2.96/4.26/4.5

12/3.226/2.312/3.530/2.326/2.630/2.626/2.930/2.926/3.230/3.226/3.526/3.754/2.630/3.530/3.754/2.826/4.054/2.930/4.0

1/1.61/1.81/2.01/2.31/2.67/2.01/2.91/3.27/2.31/3.57/2.61/3.71/4.07/2.91/4.21/4.57/3.27/1.79

7/3.57/2.37/2.07/2.67/2.25

7/2.97/2.57/3.27/2.77/2.97/2.67/3.57/3.77/2.87/3.17/2.9

19/2.4

448567698907

1,1403,2501,4001,6604,3401,9805,5102,2202,5106,8202,7703,1808,0503,9639,5905,5504,8106,9905,9808,6207,240

10,2108,5909,7808,820

12,17013,63010,29010,93010,92015,920

12.0715.2718.8524.9331.8537.7039.6348.2549.8657.7363.7164.5075.4279.2683.1095.4096.50

108.0115.5124.7138.0159.3171.7198.2209.1241.3250.1279.5286.7288.6322.5332.5326.8356.7377.1

2.0112.5453.1424.1555.309

21.9906.6058.042

29.0809.621

37.1610.7512.5746.24 13.8515.90 56.2917.61 67.35 29.0921.9937.1627.8346.2434.3656.2940.0846.2437.1667.3575.2543.1152.8446.2485.96

4.85.46.06.97.8

10.08.79.6

11.510.513.011.112.014.512.613.516.014.5717.516.116.418.218.3520.320.322.422.123.523.424.525.925.225.326.128.0

1.61.82.02.32.66.02.93.26.93.57.83.74.08.74.24.59.65.37

10.56.96.07.86.758.77.59.68.18.77.8

10.511.1

8.49.38.7

12.0

48.7361.6676.12

100.7128.6390.4160.0194.8365.2233.1466.5260.5304.6580.4335.5385.2706.8437.4845.6573.7554.7732.8693.8911.7848.5

1,1101,0071,1371,0861,3281,4841,2601,3201,3511,721

2.374 1.8781.521.1500.8990.76470.7230.5930.57750.4970.4520.4440.3800.3640.3450.3010.3010.26690.2500.2330.2100.1820.1690.1470.3190.1200.1160.1040.10060.1010.09000.08730.08880.08140.0770

81012162024253031364041475052606070737890

100110125130152160176180180203210206220240

2,2001,7001,0001,0501,0001,4001,5501,2501,0501,000

9501,2501,1001,5001,0001,3001,2501,2501,0001,3001,4501,9001,2501,4002,0001,4001,7501,5001,6501,0001,2501,6001,0001,3001,100

(Table 3)

Galvanized steel

Aluminum conductor

Aluminum Conductors, Steel Reinforced HCSR

8 Overhead Electrical Aluminum Conductors TAIHAN

Page 9: 0512 AL Conductor

ASTM

ANSI

IEC

BSAS

CSA

DIN

KSJI

SKE

PCO

TEC

ASTM

ANSI

IEC

BSAS

CSA

DIN

KSJI

SKE

PCO

TEC

Remarks1. The values of Table are those at 20 .

2. The values of calculated sectional area, outside diameter and weight are those for the standard diameters of individual wires. The electricresistance is calculated for the standard diameter, by assuming the conductivity of the hard-drawn aluminum wires at 61% and neglectingthe galvanized steel wires.

3. The sectional area of hard-drawn copper stranded conductor with equivalent resistance is calculated by assuming the conductivity of thehard-drawn copper wires at 97% and that of the hard-drawn aluminum wires for electric purposes at 61% and neglecting the length increaseby stranding.

4. The ratio of length increase by stranding to be used for calculating the weight and electric resistance shall be as follows :

5. The tensile load is calculated as 90% of the sum of the minimum tensile load of hard-drawn aluminum wire for electric purposes multipliedby the number of aluminum component wires and tensile load of galvanized steel wire multiplied by the number of steel component wires.

5430262

7771

2.72.72.61.4

0.50.50.50

Construction of CableAluminum Wires Steel Wires Aluminum Wires Steel Wires

Ratio of Length lncrease by Stranding(%)

These sizes are specified in KS.

NominalCross

SectionalArea

No. and Dia. of Strands

(No./mm)

TensileLoad

(above)

( /km, 20 ) (mm2) (m)(kgf)

Calculated CrossSectional Area

(mm2)

Outside Dia.

(mm)

Weight ElectricResistance

Hard-drawnCopper

Equiv. Area

StandardLength

Reference

(mm2) Al Al AlSt St St (kg/km)

410410420430430480480

480(Cardinal)510520580590610680690750810860950

1,160

26/4.554/3.130/4.254/3.226/4.630/4.545/3.754/3.3826/5.054/3.572/3.230/5.054/3.854/4.072/3.554/4.284/3.554/4.584/3.884/4.2

7/3.57/3.1

19/2.57/3.27/3.6

19/2.77/2.477/3.387/3.97/3.5

19/3.219/3.0

7/3.819/2.437/2.519/2.5

7/3.519/2.7

7/3.87/4.2

13,89012,27017,38012,98014,61020,16011,80015,30017,21015,60026,44024,30018,15020,31032,06022,22019,90025,71023,10027,830

413.4407.6415.5434.3432.1477483.84484.53510.6519.5579.0589.2612.4678.6692.7748.1808.2858.6952.6

1,163.7

67.3552.8493.2759.2971.26

108.8033.5462.8183.6267.35

152.80134.3

79.3885.95

181.693.2767.35

108.879.3896.98

28.527.929.428.829.231.529.6130.4231.731.535.235.034.236.038.537.838.540.541.846.2

10.59.3

12.59.6

10.813.5

7.4110.1411.710.516.015.011.412.017.512.510.513.511.412.6

1,6731,5441,8851,6451,7562,1781,5991,8362,0711,9692,6052,6892,3202,5573,3522,8072,7693,2363,2643,986

0.07020.07120.06980.06640.06710.06090.059940.059900.05680.05590.04980.04930.04740.04280.04160.03880.03590.03390.03040.0249

260255261270272300304305321327360371385430440470

-540

--

1,0001,3001,4001,1001,350

8501,0001,0001,1001,000

7001,0001,000

800600

1,000-

600--

(Table 3)

9TAIHAN Overhead Electrical Aluminum Conductors

Page 10: 0512 AL Conductor

Aluminum Conductors, Steel Reinforced -Galvanized Steel WiresACSR

These sizes are specified in KS.

ApplicationThis standard covers aluminum stranded conductors steel reinforcedwhich could withstand high tensile load to be used mainly for overheadtransmission lines, overhead distribution lines.

ConstructionThe center wire or wires are of galvanized steel and the outer layer orlayers of aluminum.

StandardsConforms to KS C 3113, JIS C 3110

Diameter Toleranceon Dia.

Min.Tensile

Strength

Min.Elongation

(kgf/mm2) (%) (times) (g/m2) (mins) (kg/km) (kgf)(mm2)

No. ofTwisting Min.

CoatingWeight

Unformity Winding WeightCalculatedCross

Sectional Area

Tensile Load

Galvanizing Test Reference

(mm) (mm)

1.82.02.252.32.42.52.62.72.93.03.13.23.53.63.73.83.94.04.24.5

0.040.040.050.050.050.050.050.050.060.060.060.060.070.070.070.070.070.080.080.09

140135135135135135135135135130130130130130130130130125125125

3.04.04.04.04.04.04.04.04.04.54.54.54.54.54.54.54.55.05.05.0

2020202020202020161616161616161616161616

200215230230230230230230245245245245260260260260260275275275

22222333444444444444

Nomarkedcrackshall

developon thecoatinglayer

of testpiece

2.5453.1423.9764.1554.5244.9095.3095.7266.6057.0697.5488.0429.621

10.1810.7511.3411.9512.5713.8515.90

19.8524.5131.0132.4135.2938.2941.4144.6651.5255.1458.8762.7375.0479.4083.8588.4593.2198.05

108.0124.0

356424537561611663719 773892919981

1,0501,2501,3201,4001,4701,5501,5701,7301,988

(Table 4)

Galvanized steel

Aluminum conductor

10 Overhead Electrical Aluminum Conductors TAIHAN

Page 11: 0512 AL Conductor

ASTM

ANSI

IEC

BSAS

CSA

DIN

KSJI

SKE

PCO

TEC

TACSR

SB : Smoth body

ApplicationThis standard covers aluminum-alloy stranded conductors steelreinforced which could withstand high tensile load to be used mainlyfor overhead transmission lines, overhead distribution lines.

ConstructionThe center wire or wires are of galvanized steel and the outer layer or layers of aluminum-alloy.

StandardsConforms to TEC, JEC 3406

Thermal-resistant Aluminum - alloy Conductor Steel Reinforced

NominalCross

SectionalArea

No. and Dia. of Strands

(No./mm)

Min.TensileLoad

Calculated CrossSectional Area

(mm2)

Outside Dia.

(mm)

Weight ElectricResistance

StandardLength

Reference

(mm2) (kgf)Al-alloy Al-alloy St Al-alloy St (kg/km) (m)( /km, 20 )St160240330410480610680810

30/2.630/3.226/4.026/4.545/3.754/3.845/4.445/4.8

7/2.67/3.27/3.17/3.57/2.477/3.87/2.97/3.2

6,97010,21010,95013,91011,26018,35015,59018,450

159.3241.3326.8413.4483.8612.4684.5814.5

37.1656.2952.8467.3533.5479.3846.2456.29

18.222.425.328.529.6134.235.138.4

7.89.69.3

10.57.41

11.48.79.6

732.81,1101,3201,6731,5992,3202,2602,700

0.1850.1220.09040.07140.06100.04810.04310.0363

2,0002,0001,6001,3002,0001,6001,4001,200

(Table 5)

Smooth Body ACSR(Taihan Standard)Nominal

CrossSectional

Area

Construction OutsideDia.

Min.Tensile

StrengthWeight

(kg/km)

ElectricResistance

Hard-drawnCopper

Equiv. Area

StandardLength

Reference

(No./shape) (No./mm)(mm2) (mm) (kgf/mm2) (mm2) (m)( /km, 20 )

Al

Al St Total

St

121925325895

120

6/SB6/SB6/SB6/SB6/SB6/SB6/SB

1/1.61/2.01/2.31/2.61/3.51/3.51/4.2

4.45.56.37.29.7

12.013.6

460698907

1,1401,9802,5103,300

33.0452.3368.8988.09

159.7261.7330.5

15.6924.5132.4141.4175.0475.04

108.0

48.7376.84

101.3129.5234.7336.7438.5

2.401.521.150.9010.4970.3030.240

3.2mm

4.0mm

145.0mm

286080

-900900900600300300

(Table 6)

Anti-corrosion ACSR : ACSR-LZ, ACSR-MZ, ACSR-HZ(Taihan Standard)Nominal

CrossSectional

Area

No. and Dia. of Strands

(No./mm)

Max.TensileLoad

Calculated CrossSectional Area

(mm2)

Outside Dia.(mm)

Weight

(kg/km)

ElectricResistance

StandardLength

Reference

Al St Al St Al St Light Medium Heavy ( /km, 20 ) (m)(mm2) (kgf)

120160200240330410520610

30/2.330/2.630/2.930/3.226/4.026/4.554/3.554/3.8

7/2.37/2.67/2.97/3.27/3.17/3.57/3.57/3.8

5,5506,9008,620

10,21010,93013,89015,60018,150

124.7159.3198.2241.3326.8413.4519.5612.4

29.0937.1646.2456.2952.8467.3567.3579.38

16.118.220.322.425.328.531.534.2

6.97.88.79.69.3

10.510.511.4

580.9742.0923.1

1,1241,3331,6901,9862,340

593.6758.2943.4

1,1491,3671,7332,0592,426

616.7787.7980.0

1,1931,4301,8132,1322,513

0.2330.1820.1470.1200.08880.07020.05590.0474

1,2002,0002,0001,8001,3001,0001,4001,200

(Table 7)

Galvanized steel

Aluminum conductor

11TAIHAN Overhead Electrical Aluminum Conductors

Page 12: 0512 AL Conductor

Conductor shall be high strength Al-clad steel core wire.

ApplicationThis standard covers aluminum stranded conductors aluminum-cladsteel reinforced which could withstand high tensile load to be usedmainly for overhead transmission lines, overhead distribution lines.

ConstructionThe center wire or wires are of aluminum-clad steel and the outer layeror layers of aluminum.

StandardsConforms to KEPCO specification

NominalCross

SectionalArea

No. and Dia.of Strands

(No/mm)

TensileLoad

(above)Calculated CrossSectional Area

(mm2)

Outside Dia.

(mm)

Al Aw Al Aw Al Aw

Weight ElectricResistance

Hard-drawnCopper

Equiv. Area

StandardLength

Reference

(mm2) (kgf) (kg/km) (mm2) (m)( /km, 20 )

3258659597

120160240330410

480(Cardinal)

480520

6/2.66/3.5

12/2.66/4.5

12/3.212/3.530/2.630/3.226/4.026/4.554/3.3845/3.754/3.5

1/2.61/3.57/2.61/4.57/3.27/3.57/2.67/3.27/3.17/3.57/3.387/2.477/3.5

1,1401,9805,4153,180

10,6009,5906,990

10,21010,93013,89015,30011,80015,600

31.8557.7363.7195.4096.50

115.45159.30241.30326.80413.40484.53483.84519.50

5.319.62

37.1715.9056.2967.3537.1656.2952.8467.3562.8133.5467.35

7.810.513.013.516.017.518.222.425.328.530.4229.6131.5

2.63.57.84.59.6

10.57.89.69.3

10.510.14

7.4110.5

120.6299.7401.0362.0608.0737.0676.4

1,0241,2391,5781,7601,5441,848

0.852000.471000.380000.285000.295000.210000.169000.111000.084200.066500.057400.058600.05360

213848636286

108163216273318310340

1,0001,0001,0001,0001,0001,0001,0001,0001,0001,0001,0001,0001,000

(Table 8)

Conductor shall be high strength Al-clad steel core wire.

Nominal CrossSectional Area ACSR/GW

(kg/km)ACSR/AW(kg/km)

GW/AW(Ratio)

ACSR/GW( /km, 20 )

ACSR/AW( /km, 20 )

GW/AW(Ratio)

Weight Conductor Resistance

(mm2)

3258659597

120160240330410

480(Cardinal)

480520

128.6233.1465.0385.1708.9845.9732.8

1,1001,3201,6731,8361,5991,969

120.6219.7401.0362.0608.0737.0676.4

1,0241,2391,5781,7601,5441,848

1.0661.0611.1601.0641.1161.1481.0831.0841.0651.0601.0431.0361.065

0.899000.497000.456500.301000.301000.250000.182000.120000.08800.070200.059900.059940.05590

0.852000.471000.380000.285000.295000.210000.169000.111000.084200.066500.057400.058600.05360

1.051.051.201.051.021.191.071.081.051.051.041.021.04

(Table 9)

Aluminum-clad steel

Aluminum conductor

Comparison of ACSR with ACSR/AW

Aluminum Conductors, Aluminum-clad Steel ReinforcedACSR/AW

12 Overhead Electrical Aluminum Conductors TAIHAN

Page 13: 0512 AL Conductor

Conductor shall be high strength Al-clad steel core wire.

Diameter Toleranceon Dia.

TensileStrength(above)

Elongation(above)

Conductivity(above)

No. ofTwisting

AIThickness

(above)

WindingCalculated

CrossSectional Area

ElectricResistance

Weight

Reference

(mm) (mm) (kgf/mm2) (%) (%) (times) (mm) ( /km, 20 )(mm2) (kg/km)

2.472.63.13.23.23.383.54.5

0.050.050.060.060.060.070.070.09

135135130130160144130125

1.51.51.51.51.51.51.51.5

20.320.320.320.314.020.320.320.3

2020161620161616

0.100.130.150.150.070.150.150.20

No markedcrack shall

developon thecoatinglayer of

test piece

4.791 5.3097.5488.0428.0428.9739.621

15.90

17.7216.011.310.615.3

9.478.835.34

31.5834.9949.7453.0057.4259.1363.40

104.81

(Table 10)

Aluminum

Steel

ASTM

ANSI

IEC

BSAS

CSA

DIN

KSJI

SKE

PCO

TEC

Aluminum-clad Steel Wires(Reference Spec. ASTM B-415)

13TAIHAN Overhead Electrical Aluminum Conductors

Page 14: 0512 AL Conductor

Stranded Aluminum-clad Steel ConductorAWSApplicationThis standard covers stranded aluminum-clad steel conductors to beused mainly for overhead ground wire.

ConstructionStranded aluminum-clad conductor

StandardsConforms to KEPCO specification

NominalCross

SectionalArea

No. andDia.

of Strands

Conductivity(above)

TensileLoad

(above)

(mm2) (mm) (kg/km) ( /km, 20 ) (m)

CalculatedCross

Sectional Area

Outside Dia. Weight ElectricResistance

StandardLength

Reference

(mm2) (No./mm) (%) (kgf)

5570

100125200200

7/3.27/3.5

19/2.619/2.919/3.719/3.7

20.320.34020.34030

6,8708,1906,360

15,48012,87016,547

56.2967.35

100.9125.5204.3204.3

9.610.513.014.518.518.5

371.2444.2474.5842961

1,162

1.5301.2700.4330.6820.2140.285

2,0002,0002,0002,0002,0002,000

(Table 11)

Aluminum-clad Steel Wires

Diameter Toleranceon Dia.

TensileStrength(above)

Elongation(above)

Conductivity(above)

No. ofTwisting(above)

AlThickness

(above)

WindingCalculated

CrossSectional Area

(mm2)

Weight

(kg/km)

ElectricResistance

( /km, 20 )

Reference

(mm) (mm) (kgf/mm2) (%) (%) (times) (mm)

2.62.93.23.53.73.7

0.050.0380.060.070.070.07

70137130130

7090

1.51.51.51.51.51.5

4020.320.320.34030

202016161616

0.330.150.150.150.470.30

No markedcrack shalldevelop onthe coating

layer oftest piece

5.3096.6058.0429.621

10.75210.752

372205

1,0501,250

753968

24.6343.5053.0063.4049.8960.32

(Table 12)

Aluminum

Steel

Aluminum

Steel

14 Overhead Electrical Aluminum Conductors TAIHAN

Page 15: 0512 AL Conductor

ASTM

ANSI

IEC

BSAS

CSA

DIN

KSJI

SKE

PCO

TEC

STACIR Super Thermal-resistant Aluminum-alloy Conductors, lnvar-reinforced

ApplicationThis standard covers super thermal-resistant aluminum-alloy strandedconductors galvanized invar reinforced to be used mainly for overheadtransmission lines.

ConstructionThe center wires are of galvanized invar and the outer layers of superthermal-resistant aluminum-alloy.

StandardsConforms to KEPCO specification

NominalCross

SectionalArea

No. andDia. ofStrands

(No./mm)

TensileLoad

(above)Calculated

Cross SectionalArea

(mm2)

Outside Dia.

(mm)

Weight ElectricResistance

Up toTransition

PointTemper-

ature

AboveTransition

PointTemper-

ature

Up toTransition

PointTemper-

ature

AboveTransition

PointTemper-

ature

Modulus ofElasticity(kg/mm2)

Coefficient ofLinear Expansion

(X10-6/ )

StandardLength

Reference

(mm2) (kgf) (kg/km) (m)( /km,20 )

ST-AlAlloy

lnvar ST-AlAlloy

lnvar ST-AlAlloy

lnvar

240330410480

ContinuousEmergencyShort Circuit

90120180

150180260

210240280

30/3.226/4.026/4.545/3.70

7/3.27/3.17/3.57/2.47

9,17010,00012,72010,500

241.3326.8413.4483.84

56.2952.8467.3533.54

22.425.328.529.61

9.69.3

10.57.41

1,1221,3301,6871,611

0.12200.09040.07140.0607

8,2307,7207,7306,960

16,50016,50016,50016,500

15.317.017.019.8

3.63.63.63.6

2,0002,0002,0002,000

(Table 13)

Maximum Operating Temperature( ) ACSR TACSR STACIR

Maximum Operating Temperature

ContinuousEmergency

1.001.00

1.55~1.621.33~1.36

1.94~2.061.60~1.67

Current Capacity lncreasing Ratio ACSR TACSR STACIR

Current Capacity Increasing Ratio

Galvanized invar

Super thermal-resistant aluminum-alloy conductor

15TAIHAN Overhead Electrical Aluminum Conductors

Page 16: 0512 AL Conductor

Super Thermal-resistant Aluminum-alloy Conductors, Aluminum-clad Invar-reinforcedSTACIR/AW

HSTACIR/AW

ApplicationThis standard covers super thermal-resistant aluminum-alloy strandedconductors aluminum-clad invar reinforced to be used mainly foroverhead transmission lines.

ConstructionThe center wires are of aluminum-clad invar and the outer layers ofsuper thermal-resistant aluminum-alloy.

StandardsConforms to KEPCO specification

Aluminum-clad invar

Super thermal-resistant aluminum-alloy conductor

NominalCross

SectionalArea

No. and Dia. of Strands

(mm)

TensileLoad

(above)Calculated

Cross SectionalArea

(mm2)

Outside Dia.

(mm)

Weight ElectricResistance

Up toTransition

PointTemper-

ature

AboveTransition

PointTemper-

ature

Up toTransition

PointTemper-

ature

AboveTransition

PointTemper-ature to230

Above230

Modulus of Elasticity(kg/mm2)

Coefficient of Linear Expansion(X10-6/ )

StandardLength

Reference

(mm2) (kgf) (kg/km) (m)( /km,20 )

ST-AlAlloy

Al-cladlnvar

ST-AlAlloy

ST-AlAlloy

Al-cladlnvar

Al-cladlnvar

240330410480

30/3.226/4.026/4.545/3.70

7/3.27/3.17/3.57/2.47

9,17010,00012,72010,500

241.3326.8413.4483.84

56.2952.8467.3533.54

22.425.328.529.61

9.69.3

10.57.41

1,0701,2851,6251,580

0.11590.08690.06860.0600

8,0407,5807,5806,900

15,50015,50015,50015,500

16.017.517.520.0

3.73.73.73.7

10.810.810.810.8

2,0002,0002,0002,000

(Table 14)

High-strength Super Thermal-resistant Alluminum-alloy ConductorsAluminum-clad Invar Reinforced

ApplicationThis standard cover High-strength super thermal-resistant aluminum-alloy stranded conductors aluminum-clad invar reinforced to be usedmainly for overhead transmission lines.

ConstructionThe center wires are of aluminum-clad high strength invar and theouter layers of super thermal-resistant aluminum-alloy.

StandardsConforms to KEPCO specification

Aluminum-clad high strength inver

Super thermal-resistant aluminum-alloy conductor

NominalCross

SectionalArea

No. and Dia. of Strands

(mm)

TensileLoad

(above)Calculated CrossSectional Area

(mm2)

Outside Dia.

(mm)

Weight ElectricResistance

Up toTransition

PointTemper-

ature

AboveTransition

PointTemper-

ature

Up toTransition

PointTemper-

ature

AboveTransition

PointTemper-ature to230

Above230

Modulus of Elasticity(kg/mm2)

Coefficient of Linear Expansion(X10-6/ )

StandardLength

Reference

(mm2) (kgf) (kg/km) (m)( /km,20 )

ST-AlAlloy

Al-cladHigh-

Strengthlnvar

ST-AlAlloy

ST-AlAlloy

Al-cladHigh-

Strengthlnvar

Al-cladHigh-

Strengthlnvar

240330410480

30/3.226/4.026/4.545/3.7

7/3.27/3.17/3.57/2.47

9,70010,50013,30011,000

241.3326.8413.5483.8

56.2952.8467.3533.54

22.425.328.529.61

9.69.3

10.57.41

1,0701,2851,6251,580

0.11590.08690.06860.0600

8,0417,5817,5896,896

15,50015,50015,50015,500

15.9617.5117.4820.19

3.73.73.73.7

10.810.810.810.8

2,0002,0002,0002,000

(Table 15)

16 Overhead Electrical Aluminum Conductors TAIHAN

Page 17: 0512 AL Conductor

ASTM

ANSI

IEC

BSAS

CSA

DIN

KSJI

SKE

PCO

TEC

HTACSR/AW

TACSR/AW Thermal-resistant Aluminum-alloy Conductors, Aluminum-clad Steel-reinforced

ApplicationThis standard covers thermal-resistant aluminum-alloy strandedconductors aluminum-clad steel reinforced to be used mainly foroverhead transmission lines.

ConstructionThe center wires are of aluminum-clad steel and the outer layers ofthermal-resistant aluminum-alloy.

StandardsConforms to KEPCO specification

Aluminum-clad steel

Thermal-resistant aluminum-alloy conductor

NominalCross

SectionalArea

No. and Dia. of Strands

(No./mm)

TensileLoad

(above)Calculated CrossSectional Area

(mm2)

Outside Dia.

(mm)

Weight ElectricResistance

StandardLength

Reference

(mm2) (kgf)Al-alloy Al-alloy AW Al-alloy AW (kg/km) (m)( /km, 20 )AW480(Rail) 45/3.7 7/2.47 11,260 483.84 33.54 29.61 7.41 1,561 0.0596 2,000

(Table 16)

High-Strength, Thermal-resistant Aluminum-alloy Conductors,Aluminum-clad Steel Reinforced

ApplicationThis standard covers high-strength, thermal-resistant aluminum-alloystranded conductors aluminum-clad steel reinforced which couldwithstand extra high tensile load to be used mainly for overheadtransmission lines.

ConstructionThe center wires are of aluminum-clad steel and the outer layers ofhigh-strength, themal-resistant aluminum-alloy.

StandardsConforms to KEPCO specification

Aluminum-clad steel

High-strength, thermal-resistant aluminum-alloy conductor

NominalCross

SectionalArea

No. and Dia. of Strands

(No./mm)

TensileLoad

(above)Calculated CrossSectional Area

(mm2)

Outside Dia.

(mm)

Weight ElectricResistance

StandardLength

Reference

(mm2) (kgf)HT-Al Alloy HT-Al Alloy AW HT-Al Alloy AW (kg/km) (m)( /km, 20 )AW480

(Cardinal) 54/3.38 7/3.38 18,880 484.53 62.81 30.42 10.14 1,756 0.0633 2,000

(Table 17)

17TAIHAN Overhead Electrical Aluminum Conductors

Page 18: 0512 AL Conductor

Hard-drawn Aluminum Conductor Weather-resistantInsulation WiresHAL-OC

ApplicationThis standard covers HAL-OC(for use in 6,600~22,900 volts circuits) tobe used weather-resistant insulation wire for the distribution ofelectrical energy under the normal conditions of overhead line service.

ConstructionSolid or stranded hard-drawn aluminum conductor and cross-linkedpolyethylene insulation

StandardsConforms to KS C 3139, ES 121-250, 121-255

NominalCross

SectionalArea

lnsulationThickness

Conductor OutsideDia.No. and

Dia. of Strands

OutsideDia.

Max.Electric

Resistance

Min.lnsulationResistance

TestVoltage

TensileLoad

Weight StandardLength

(mm2) (mm) (mm) (mm) ( /km, 20 ) ( km, 20 ) (V/1mins) (kgf) (kg/km) (m)(No./mm)

150 19/3.2 16.0 2.5 21.0 0.193 1,000 12,000 2,270 600 300

(Table 18)Within 6.6kV

NominalCross

SectionalArea

lnsulationThickness

Conductor OutsideDia.No. and

Dia. of Strands

OutsideDia.

Max.Electric

Resistance

Min.lnsulationResistance

TestVoltage

TensileLoad

Weight StandardLength

(mm2) (mm) (mm) (mm) ( /km, 20 ) ( km, 20 ) (V/1mins) (kgf) (kg/km) (m)(No./mm)

150 19/3.2 16.0 4.0 24.0 0.193 1,500 25,000 2,270 650 600

(Table 19)Within 22.9kV

Aluminum conductor

XLPE insulation

18 Overhead Electrical Aluminum Conductors TAIHAN

Page 19: 0512 AL Conductor

ASTM

ANSI

IEC

BSAS

CSA

DIN

KSJI

SKE

PCO

TEC

ACSR-OC Aluminum, Steel-reinforced(ACSR) ConductorWeather-resistant Insulation Wire

ApplicationThis standard covers ACSR-OC(for use in 6,600~22,900 volts circuits)to be used weather-resistant insulation wire for the distribution ofelectrical energy under the normal conditions of overhead line service.

NominalCross

SectionalArea

lnsulationThickness

OutsideDia.

Max.Electric

Resistance

Min.lnsulationResistance

TestVoltage

TensileLoad

Weight StandardLength

Conductor

No. and Dia. of Strands(No./mm)

OutsideDia.

(mm2) (mm) (mm) (mm) (V/1mins) (kgf) (kg/km) (m)( /km, 20 ) ( km, 20 )Al St325895

6/SB6/SB6/SB

1/2.61/3.51/3.5

7.29.7

12.0

2.02.52.5

11.214.717.0

0.9280.5120.313

1,5001,5001,000

12,00012,00012,000

1,0901,9002,360

185325455

900600300

(Table 20)

ConstructionAluminum, steel-reinforced conductor and cross-linked polyethyleneinsulation

StandardsConforms to KS C 3138, ES 121-200-202, 121-230-275

Within 6.6kV

NominalCross

SectionalArea

lnsulationThickness

OutsideDia.

Max.Electric

Resistance

Min.lnsulationResistance

TestVoltage

TensileLoad

Weight StandardLength

Conductor

No. and Dia. of Strands(No./mm)

OutsideDia.

(mm2) (mm) (mm) (mm) (V/1mins) (kgf) (kg/km) (m)( /km, 20 ) ( km, 20 )Al St325895

160

6/SB6/SB6/SB

18/SB

1/2.61/3.51/3.51/3.2

7.29.7

12.015.4

3.03.03.54.0

13.215.719.023.4

0.9280.5120.3130.186

2,0001,5001,5001,500

25,00025,00025,00025,000

1,0901,9002,3603,080

215340540740

900600600600

(Table 21)Within 22.9kV

Galvanized steel

XLPE insulation

Aluminum conductor

SB : Smooth body

SB : Smooth body

19TAIHAN Overhead Electrical Aluminum Conductors

Page 20: 0512 AL Conductor

Aluminum, Al-clad, Steel-reinforced(ACSR/AW) Conductor Weather-resistant Insulation WiresACSR/AW-OC

ApplicationThis standard covers ACSR/AW-OC(for use in 6,600~22,900 voltscircuits) to be used weather-resistant insulation wire for the distributionof electrical energy under the normal conditions of overhead line service.

ConstructionAluminum, Al-clad steel-reinforced conductor and cross-linkedpolyethylene insulation

StandardsConforms to KEPCO specification

XLPE insulation Aluminum

Al-clad

NominalCross

SectionalArea

lnsulationThickness

OutsideDia.

ElectricResistance

Min.lnsulationResistance

TestVoltage

TensileLoad

Weight StandardLength

Conductor

No. and Dia. of Strands(No./mm)

OutsideDia.

(mm2) (mm) (mm) (mm) (V/1mins) (kgf) (kg/km) (m)( /km, 20 ) ( km, 20 )Al AW325895

6/SB6/SB6/SB

1/2.61/3.51/3.5

7.29.7

12.0

2.02.52.5

11.214.717.0

0.8770.4840.302

1,5001,5001,000

12,00012,00012,000

1,0901,9002,360

180315445

900600300

(Table 22)Within 6.6kV

SB : Smooth body

NominalCross

SectionalArea

lnsulationThickness

OutsideDia.

ElectricResistance

Min.lnsulationResistance

TestVoltage

TensileLoad

Weight StandardLength

Conductor

No. and Dia. of Strands(No./mm)

OutsideDia.

(mm2) (mm) (mm) (mm) (V/1mins) (kgf) (kg/km) (m)( /km, 20 ) ( km, 20 )Al AW325895

160240

6/SB6/SB6/SB

18/SB18/SB

1/2.61/3.51/3.51/3.21/4.0

7.29.7

12.015.418.9

3.03.03.54.04.0

13.215.719.023.427.0

0.8770.4840.3020.1830.123

2,0001,5001,5001,5001,500

25,00025,00025,00025,00025,000

1,0901,9002,3603,0804,500

210330530730

1,040

900600600600600

(Table 23)Within 22.9kV

SB : Smooth body

20 Overhead Electrical Aluminum Conductors TAIHAN

Page 21: 0512 AL Conductor

American Society for Testing and Materials

American National Standards Institute

ASTM

ANSI

21TAIHAN Overhead Electrical Aluminum Conductors

Page 22: 0512 AL Conductor

Hard-drawn Aluminum Wires for Electric PurposesHAL

ApplicationThis standard covers hard-drawn circular aluminum wires for electricpurposes to be used mainly as component wires of hard-drawnaluminum stranded cables and aluminum cables steel reinforced.

ConstructionSingle aluminum conductor

StandardsConforms to ASTM B 230-97

(Table 24)Tensile RequirementsDiameter

ksi Mpa ksi MpaAverage for a Lot

IndividualTests

Average for a Lot

IndividualTests( %, or in)

Toleranceon Dia.

Average for a Lot lndividual Tests

Min. Tensile Strength Min. Elongation in10 in or 250mm

(%)

Min. VolumeConductivity

(% IACS, 20 (68 ))

in mm

0.2600 to 0.21010.2100 to 0.18010.1800 to 0.15010.1500 to 0.14010.1400 to 0.12010.1200 to 0.11010.1101 to 0.10010.1000 to 0.09010.0900 to 0.08010.0800 to 0.07010.0700 to 0.06010.0600 to 0.05010.0500 to 0.0105

6.604 to 5.3375.334 to 4.5754.572 to 3.8133.810 to 3.5593.556 to 3.0513.048 to 2.7972.794 to 2.5432.540 to 2.2892.286 to 2.0352.032 to 1.7811.778 to 1.5271.524 to 1.2731.270 to 0.267

1%1%1%1%1%1%1%

0.0010 in0.0010 in0.0010 in0.0010 in0.0010 in0.0010 in

23.524.024.024.525.025.526.027.027.528.028.529.025.0

162165165169172176179186190193197200172

22.523.023.023.523.524.024.525.526.026.527.027.023.0

155159159162162165169176179183186186159

2.32.12.01.91.81.71.61.61.61.61.51.4-

2.22.01.91.81.71.61.51.51.51.41.31.2-

61.261.261.261.261.261.261.261.261.261.261.261.261.2

61.061.061.061.061.061.061.061.061.061.061.061.061.0

(Table 25)Equivalent Resistivity Values at 20 C(68 F)

MaterialVolume

Conductivity(% IACS)

Resistivity ConstantsWeightVolume

cmil/ft mm2/m in cm -lb/mile2 -g/m2

CopperAluminumAluminum

10061.061.2

10.37117.00216.946

0.0172410.0282650.028172

0.678791.11281.1091

1.72412.82652.8172

875.20436.23434.81

0.153280.0763990.076149

22 Overhead Electrical Aluminum Conductors TAIHAN

Page 23: 0512 AL Conductor

AST

MA

NSI

IEC

BSAS

CSA

DIN

KSJI

SKE

PCO

TEC

Zinc-coated(galvanized) Steel Core Wire (ASTM B 498-93)

(Table 26)

(Table 27)

Tensile Requirements and Permissible Variations in Diameter

Mpa ksi Mpa (%) Plus

in mm

Minus Plus Minusksi

Nominal Dia. Min. Stressat 1% Extension

Min. UltimateTensile Strength

Min.Elogationin 10 in

or 250mm

Permissible Variation

Class A Coating

in mm

0.0500 to 0.08990.0900 to 0.11990.1200 to 0.13990.1400 to 0.1900

1.270 to 2.2832.286 to 3.0453.048 to 3.5533.556 to 4.822

190185180170

1,3101,2801,2401,170

210205205200

1,4501,4101,4101,380

3.03.54.04.0

0.00150.0020.0030.004

0.0010.0020.0020.003

0.0380.0510.0760.102

0.0250.0510.0510.076

Class B Coating

0.0500 to 0.08990.0900 to 0.11990.1200 to 0.13990.1400 to 0.1900

1.270 to 2.2832.286 to 3.0453.048 to 3.5533.556 to 4.822

180175170160

1,2401,2101,1701,100

200195195185

1,3801,3401,3401,280

3.03.03.04.0

0.00150.0020.0030.004

0.0010.0020.0020.003

0.0380.0510.0760.102

0.0250.0510.0510.076

Class C Coating

0.0500 to 0.08990.0900 to 0.11990.1200 to 0.13990.1400 to 0.1900

1.270 to 2.2832.286 to 3.0453.048 to 3.5533.556 to 4.822

170165160155

1,1701,1401,1001,070

190185185180

1,3101,2801,2801,240

3.03.03.04.0

0.00150.0020.0030.004

0.0010.0020.0020.003

0.0380.0510.0760.102

0.0250.0510.0510.076

Minimum Weight of Coating and Mandrel Size for Adherence Test

Nominal Dia. of Coated WireMin. Weight of Zinc-coating

oz/ft2 of Uncoated Wire Surface

Coatingin mm

CoatingClass A Class B Class C Class A Class B Class C

Ratio ofMandrelDia. to

Wire Dia.

Min. Weight of Zinc-coatingg/m2 of Uncoated Wire Surface

0.0500 to 0.05990.0600 to 0.07490.0750 to 0.08990.0900 to 0.10390.1040 to 0.11990.1200 to 0.13990.1400 to 0.17990.1800 to 0.1900

1.270 to 1.5211.524 to 1.9021.905 to 2.2832.286 to 2.6392.642 to 3.0453.048 to 3.5533.556 to 4.5694.572 to 4.822

0.600.650.700.750.800.850.901.00

1.201.301.401.501.601.701.802.00

1.801.952.102.252.402.552.703.00

183198214229244259274305

366396437458488518549610

549550610686732778824915

33344455

23TAIHAN Overhead Electrical Aluminum Conductors

Page 24: 0512 AL Conductor

Stranded Hard-drawn Aluminum ConductorAAC

Notes : Class AA - For bare conductors usually used in overhead lines.Class A - For conductors to be covered with weather-resistant materials.

ApplicationThis standard covers stranded hard-drawn aluminum conductors to beused mainly for overhead distribution wire, overhead feeders andbuses.

ConstructionStranded hard-drawn aluminum conductor

StandardsConforms to ASTM B 231-95

CodeWord

ConductorDia.

(in)

Weight

(lb/1000ft)

RatedStrength

(lb)

CalculatedResistance

at 20(68 )

( /1000ft)

Ampacity

(amps)

AWGor

CMILS

sq in Class No. andDia. ofStrands

(in)

Conductor Size Stranding

PeachbellRoseLilyIrisPansyPoppyAsterPhloxOxlipSneezewortValerianDaisyLaurelPeonyTulipDaffodilCannaGoldentuftCosmosSyringaZinniaHyacinthDahliaMistletoeMeadowsweetOrchidHeucheraVerbenaFlagViolet

64321

1/02/03/04/0

250,000250,000266,800266,800300,000336,400350,000397,500450,000477,000477,000500,000500,000556,500556,500600,000636,000650,000700,000700,000715,500

0.02060.03280.04130.05210.06570.08290.10450.13180.16620.19640.19640.20950.20950.23560.26420.27490.31220.35340.37460.37460.39270.39270.43710.43710.47170.49950.51050.54980.54980.5620

AAA

A&AAA&AAA&AAA&AAA&AAA&AA

AAA

AAAAAA

A&AAAAAAA

AAAA

A&AAA&AA

AAAAAAA

AA

7 0.06127 0.07727 0.08677 0.09747 0.10937 0.12287 0.13797 0.15487 0.17397 0.1890

19 0.11477 0.1953

19 0.118519 0.125719 0.133119 0.135719 0.144719 0.153919 0.158437 0.113519 0.162237 0.116219 0.171137 0.122637 0.127337 0.131137 0.132637 0.137561 0.107137 0.1391

0.1840.2320.2600.2920.3280.3680.4140.4640.5220.5670.57405860.5930.6290.6660.6790.7240.7700.7920.7950.8110.8130.8560.8580.8910.9180.9280.9630.9640.974

24.639.149.462.278.498.9

124.8157.2198.4234.4234.7250.2250.1281.4315.5327.9372.9421.8446.8446.8468.5468.3521.4521.3562.0596.0609.8655.7655.8671.0

563881

1,0231,3501,6401,9902,5103,0403,8304,5204,5104,8304,9705,4806,1506,3907,1107,8908,3608,6908,7609,1109,7509,940

10,70011,40011,60012,50012,90012,800

0.66090.41550.32960.26130.20720.16420.13030.10330.081960.06940.06940.065000.065000.05780.05150.04960.043630.03860.036360.036360.3470.3470.031160.031160.02890.027270.02670.02480.02480.02424

103138159185214247286330382414416442444458513521570612639640669670703704721765782804805823

(Table 28)

24 Overhead Electrical Aluminum Conductors TAIHAN

Page 25: 0512 AL Conductor

AST

MA

NSI

IEC

BSAS

CSA

DIN

KSJI

SKE

PCO

TEC

(Table 28)

Notes : Class AA - For bare conductors usually used in overhead lines.Class A - For conductors to be covered with weather-resistant materials.

CodeWord

ConductorDia.

(in)

Weight

(lb/1000ft)

RatedStrength

(lb)

CalculatedResistance

at 20(68 )

( /1000ft)

Ampacity

(amps)

AWGor

CMILS

sq in Class No. andDia. ofWires(in)

Conductor Size Stranding

NasturtiumPetuniaCattailArbutusLilacAnemoneCrocusCockscombSnapdragonMagnoliaGoldenrodHawkweedCamelliaBluebellLarkspurMarigoldHawthornNarcissusColumbineCarnationGladiolusCoreopsisDogwoodJessamineCowslipSagebrushLupineBitterrootTrilliumBluebonnet

715,500750,000750,000795,000795,000874,500874,500900,000900,000954,000954,000

1,000,0001,000,0001,033,5001,033,5001,113,0001,192,5001,272,0001,351,0001,431,0001,510,5001,590,0001,590,0001,750,0002,000,0002,250,0002,500,0002,750,0003,000,0003,500,000

0.56200.58900.58900.62440.62440.68680.68680.70690.70690.74930.74930.78540.78540.81170.81170.87410.93660.9990

1.0621.1241.1861.2491.2491.3741.5701.7661.9622.1582.3502.749

AAAA

AAA

AAA

AAA

AAA

AAA

AAA

A&AAA&AAA&AAA&AAA&AAA&AA

AAA

AAAAAAAA

61 0.108337 0.142461 0.110937 0.146661 0.114237 0.153861 0.119837 0.156061 0.121537 0.160661 0.125137 0.164461 0.128037 0.167161 0.130261 0.135161 0.139861 0.144461 0.148861 0.153261 0.157461 0.161491 0.132261 0.169491 0.148291 0.157291 0.165791 0.1738

127 0.1537127 0.1660

0.9750.9970.9981.0261.0281.0771.0781.0921.0941.1241.1261.1511.1521.1701.1721.2161.2581.3001.3391.3791.4171.4531.4541.5251.6301.7291.8231.9121.9962.158

671.0703.2703.2745.3745.7821.0821.0844.0844.0894.5894.8937.3936.8968.4969.2

1,0441,1171,1921,2661,3421,4171,4891,4931,6411,8732,1282,3652,6022,8403,345

13,10013,10013,50013,90014,30014,83015,76016,40015,90016,40016,90017,20017,70017,70018,30019,70021,10022,00023,40024,30025,60027,00028,10029,70034,20037,70041,90046,10050,30058,700

0.024240.02310.02310.021810.021810.019830.019830.01930.01930.018180.018180.01740.01730.016780.016780.015580.014540.013630.012830.012120.011480.010910.010910.009910.008680.007790.007010.006370.005840.00505

824842848874878932932938943982982

1,0031,0051,0311,0321,0791,1251,1701,2121,2541,2951,3341,3341,4991,5951,6861,7721,9532,2832,689

25TAIHAN Overhead Electrical Aluminum Conductors

Page 26: 0512 AL Conductor

Aluminum Conductors, Steel ReinforcedACSR

ApplicationThis standard covers aluminum stranded conductors steel reinforcedwhich could withstand high tensile load to be used mainly for overheadtransmission lines, overhead distribution lines.

ConstructionThe center wire or wires are of galvanized steel and the outer layer orlayers of aluminum.

StandardsConforms to ASTM B 232-97

CodeWord

Outside Dia.

(in)

Weight

(lb/1000ft)

UltimateStrength

(lb)

Resistanceat 20

( /1000ft)

Ampacity

(Amps)

AWGor

CMILS

Cross SectionalArea (sq in)

Al Total Al St Total Al StComplete

CableSteelCore

Stranding

Conductor Size

TurkeyThrushSwanSwanateSwallowSparrowSparateRobinRavenQuailPigeonPenguinWaxwingPartridgeOstrichMerlinLinnetOrioleChickadeeBrantIbisLarkPelicanFlickerHawkHenOspreyParakeetDoveEaglePeacockSquabWood DuckTealRook

65443221

1/02/03/04/0

266,800266,800300,000336,400336,400336,400397,500397,500397,500397,500477,000477,000477,000477,000556,500556,500556,500556,500605,000605,000605,000605,000636,000

0.02060.02600.03280.03280.04130.05210.05210.06570.08290.10450.13180.16620.20950.20950.23560.26420.26420.26420.31220.31220.31220.31220.37460.37460.37460.37460.43710.43710.43710.43710.47520.47520.47520.47520.4955

0.02400.03030.03830.04110.04820.06080.06530.07670.09670.12190.15380.19390.22110.24360.27400.27890.30720.32590.32950.35250.36300.38500.39540.42320.43560.46200.46140.49380.50830.53910.53680.55260.58610.58350.5643

6 0.06616 0.07436 0.08347 0.07726 0.09376 0.10527 0.09746 0.11816 0.13276 0.14896 0.16726 0.1878

18 0.121726 0.101326 0.107418 0.136726 0.113730 0.105918 0.148624 0.128726 0.123630 0.115118 0.162824 0.141026 0.135430 0.126118 0.175824 0.152326 0.146330 0.136224 0.158826 0.152530 0.142030 0.142024 0.1628

1 0.06611 0.07431 0.08341 0.10291 0.09371 0.10521 0.12991 0.11811 0.13271 0.14891 0.16721 0.18781 0.12177 0.07887 0.08351 0.13677 0.08847 0.10591 0.14867 0.08587 0.09617 0.11511 0.16287 0.09407 0.10537 0.12611 0.17587 0.10157 0.11387 0.13627 0.10597 0.11867 0.1420

19 0.08527 0.1085

0.1980.2230.2500.2570.2810.3160.3250.3540.3980.4470.5020.5630.6090.6420.6800.6840.7200.7410.7430.7720.7830.8060.8140.8460.8580.8830.8790.9140.9270.9530.9530.9660.9940.9940.997

0.06610.07430.08340.10290.09370.10520.12990.11810.13270.14890.16720.18780.12170.23640.25050.13670.26520.31770.14860.25740.28830.34530.16280.28200.31590.37830.17580.30450.34140.40860.31770.35580.42600.25560.3255

36.145.557.467.072.491.3

106.7115.2145.2183.1230.8291.1290367413365463527432512547623518615657747604717766872780833948940819

24.530.939.039.049.262.062.078.298.6

124.3156.8197.7250.5251.7283.0315.8317.3318.1373.2375375.0375.9447.8450.0450.0451.1522.4525.0525.0526.3570.7570.7572572.1600.0

11.614.618.428.023.329.344.737.046.658.874.093.439.2

115.6129.849.5

145.8209

58.5137171.9246.9

70.2164.5206.8296.3

81.9191.8241.1345.7208.8261.9376367.6219.2

1,1901,4901,8602,3602,2502,8503,6403,5504,3805,3006,6208,3506,900

11,30012,700

8,62014,10017,300

9,90014,60016,30020,30011,80017,20019,50023,80013,70019,80022,60027,80021,60024,30028,90030,00022,600

0.6577-

0.41340.4134

-0.26010.26010.20620.16340.12970.10280.81550.065000.065320.058090.051550.051810.051930.043630.043840.043840.043950.036360.036540.036540.036620.031160.031320.031320.031390.028800.028200.02890.02890.02740

104-

139139

-183184210240275316360448457492518528534575578586593644654658665708718725732757762769772782

(Table 29)

Galvanized steel

Aluminum conductor

26 Overhead Electrical Aluminum Conductors TAIHAN

Page 27: 0512 AL Conductor

AST

MA

NSI

IEC

BSAS

CSA

DIN

KSJI

SKE

PCO

TEC

CodeWord

Outside Dia.

(in)

Weight

(lb/1000ft)

UltimateStrength

(lb)

Resistanceat 20

( /1000ft)

Ampacity

(Amps)

AWGor

CMILS

Cross SectionalArea (sq in)

Al Total Al St Total Al StComplete

CableSteelCore

Stranding

Conductor Size

GrosbeakSwiftScoterKingbirdEgretFlamingoGannetCrowStarlingRedwingStiltDrakeMallardTernCondorCootCuckooCraneCanaryRuddyRailCardinalCatbirdOrtolanCurlewTanagerBluejayFinchBuntingGrackleBitternPheasantDipperMartinBobolinkPloverNuthatchParrotLapwingFalconChukarBluebirdKiwiThrasher

636,000636,000636,000636,000636,000666,600666,600715,500715,500715,500715,500795,000795,000795,000795,000795,000795,000874,500900,000900,000954,000954,000954,000

1,033,5001,033,5001,033,5001,113,0001,113,0001,192,5001,192,5001,272,0001,272,0001,351,5001,351,5001,431,0001,431,0001,510,5001,510,5001,590,0001,590,0001,780,0002,156,0002,167,0002,312,000

0.49950.49750.49950.49950.49950.52350.52350.56200.56200.56200.56280.62440.62440.62440.62440.62440.62440.68680.70690.70690.74930.74930.74930.81170.81170.81170.87410.87410.93670.93660.99900.99901.0621.06251.1241.1241.1861.1861.2491.2491.3981.6931.7021.816

0.58090.51340.61610.52920.61340.59140.60870.63480.65350.69010.63560.72610.76680.66760.70530.64170.70530.77590.79850.75550.80110.84640.77010.86780.91690.83420.93460.98491.0011.0551.0681.1261.1351.1961.2021.2661.2681.3371.3351.4071.5121.8281.7761.915

26 0.156436 0.132930 0.145618 0.188030 0.145624 0.166726 0.160154 0.115126 0.165930 0.154424 0.172726 0.174930 0.162845 0.132954 0.121336 0.148624 0.182054 0.127354 0.129145 0.141445 0.145654 0.132936 0.162845 0.151554 0.138336 0.169445 0.157354 0.143645 0.162854 0.148645 0.168154 0.153545 0.173354 0.158245 0.178354 0.162845 0.183254 0.167245 0.188054 0.171684 0.145684 0.160272 0.173576 0.1744

7 0.12161 0.13297 0.14561 0.1880

19 0.08747 0.11117 0.12457 0.11517 0.1290

19 0.09267 0.11517 0.1360

19 0.09777 0.08867 0.12131 0.14867 0.12137 0.12737 0.12917 0.09437 0.09717 0.13291 0.16287 0.10107 0.13831 0.16947 0.1049

19 0.08627 0.1085

19 0.08927 0.1121

19 0.09217 0.1151

19 0.09497 0.1189

19 0.09777 0.1221

19 0.10037 0.1253

19 0.103019 0.087419 0.09617 0.1157

19 0.0814

0.9900.9301.0190.9401.0191.0001.0141.0361.0511.0811.0361.1081.1401.0631.0921.0401.0921.1461.1621.1311.1651.1961.1401.2121.2451.1861.2591.2931.3021.3381.3451.3821.3861.4241.4271.4651.4661.5051.5041.5451.6021.7621.7351.802

0.36480.13290.43680.18800.43700.33330.37350.34530.38700.46300.34530.40800.48850.26580.36390.14860.36390.38190.38730.28290.29130.39870.16280.30300.41490.16940.31470.43100.32550.44600.33630.46050.34530.47450.35670.48850.36630.50150.37590.51500.43700.48050.34710.4070

875644993690988859918921985

1,111922

1,0941,235

8961,024

8051,0241,1261,1591,0151,0751,229

9661,1651,3311,0461,2551,4311,3441,5331,4341,6351,5231,7371,6131,8401,7021,9421,7922,0442,0742,5122,3042,527

600.0597601597601.4628.8629675.0675.0676.6675750.0751.8750.0750.0746750825.0849.0849900.0900.0896975.0975.0970

1,0501,0551,1251,1301,2001,205.81,2751,281.21,3501,356.51,4251,4321,5001,5071,6872,0442,0552,191

275.347

39293

386.8229.8289246.4309.8434.2247344.3483.3146.0274.1

59274301.4310.0166175.0328.5

70190.0356.3

76205376219403234429.5248456263483.3277510292537387468249336

25,20013,80030,40015,70031,50023,70026,40026,30028,40034,60025,50031,50038,40022,10028,20016,80027,90031,40031,90024,40025,90033,80019,80027,70036,60021,40029,80039,10032,00041,90034,10043,60036,20046,30038,30049,10040,10051,70042,20054,50051,00060,30049,80056,700

0.027400.02740.02750.02730.027470.026140.02610.024360.024360.024420.024360.021920.021970.021920.021920.02180.02190.019930.019360.01940.018270.018270.01810.016860.016860.01670.015660.015730.014610.014690.013700.013770.012900.012960.012180.012240.011540.011590.010960.011010.009840.00800.00800.00749

787784792778797805809825847858845903913875881905894935926918953960972

1,0051,0101,0071,0511,0601,0991,1081,1451,1481,1881,1981,2271,2371,2681,2781,3101,3131,4341,6201,6341,875

(Table 29)

27TAIHAN Overhead Electrical Aluminum Conductors

Page 28: 0512 AL Conductor

Aluminum Conductors, Aluminum-clad Steel ReinforcedACSR/AW

Note : Class AA - For bare conductors usually used in overhead lines.

ApplicationThis standard covers aluminum stranded conductors aluminum-cladsteel reinforced which could withstand high tensile load to be usedmainly for overhead transmission lines, overhead distribution lines.

ConstructionThe center wire or wires are of aluminum-clad steel and the outer layeror layers of aluminum.

StandardsConforms to ASTM B 549-93

Conductor Size (Al Wire)

CMILS AWG mm2 ClassNo. ofWires

No. ofWiresin mm in mm

Nominal Dia. Nominal Dia.Aluminum Aluminum-clad Steel

kips(1000 lbf)

kN lb/10000ft kg/km

Stranding Rated Strength Linear Density

2,312,0002,167,0002,156,0001,780,0001,590,0001,590,0001,510,0001,510,0001,431,0001,431,0001,351,0001,351,0001,272,0001,272,0001,272,0001,192,5001,192,5001,113,0001,113,0001,033,5001,033,5001,033,500

954,000954,000954,000900,000900,000795,000795,000795,000795,000795,000795,000715,000715,000715,000666,600

1,1711,0981,092

901.9805.7805.7765.1765.1725.1725.1684.6684.6644.5644.5644.5604.2604.2564.0564.0523.7523.7523.7483.4483.4483.4456.0456.0402.8402.8402.8402.8402.8402.8362.3362.3362.3337.8

AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA

76728484544554455445544554453654455445544536544536544530544526243630262426

0.17440.17350.16020.14560.17160.18800.16720.18320.16280.17830.15820.17330.15350.16810.18800.14860.16280.14360.15730.13830.15150.16940.13290.14560.16280.12910.14140.16280.12130.13290.17490.18200.14860.15440.16590.17270.1601

4.4304.4074.0693.6984.3594.7754.2474.6534.1354.5294.0184.4023.8994.2704.7753.7744.1353.6473.9953.5133.8484.3033.3763.6984.1353.2793.5924.1353.0813.3764.4424.6233.7743.9224.2144.3874.067

197

1919197

197

197

197

1971

197

19777177177

1977771

19777

0.08140.11570.09610.08740.10300.12530.10030.12210.09770.11890.09490.11550.09210.11210.18800.08920.10850.08620.10490.13830.10100.16940.13290.09710.16280.12910.09430.09770.12130.08860.13600.12130.14860.09260.12900.11510.1245

2.0682.9392.4412.2202.6163.1832.5483.1012.4823.0202.4102.9342.3392.8474.7752.2662.7562.1892.6643.5132.5654.3033.3762.4664.1353.2792.3952.4823.0812.2503.4543.0813.7742.3523.2772.9243.162

55.349.159.049.453.041.850.339.747.737.645.135.542.433.425.740.231.337.529.335.627.121.132.925.419.531.024.037.127.821.530.527.516.633.427.524.826.0

24621926222023618622417621216720015818914911417913916713015812193.714611386.613810716512495.413612273.8148122110116

2,4722,2622,4372,0131,9601,7461,8601,6581,7641,5701,6651,4831,5681,3961,2721,4701,3091,3731,2221,2741,1341,0331,1771,047

9541,111

9381,160

980872

1,041981795

1,043936883872

3,6783,3673,5282,9952,9172,5982,7682,4672,6252,3372,4782,2072,3332,0771,8932,1871,9482,0431,8191,8961,6871,5371,7511,5581,4191,6531,4701,7261,4591,2981,5491,4591,1821,5521,3931,3141,298

(Table 30)

Aluminum-clad steel

Aluminum conductor

28 Overhead Electrical Aluminum Conductors TAIHAN

Page 29: 0512 AL Conductor

AST

MA

NSI

IEC

BSAS

CSA

DIN

KSJI

SKE

PCO

TEC

Notes : Class AA - For bare conductors usually used in overhead lines.Class A - For conductors to be covered with weather-resistant materials.(+) : Indicates conductors with high strength to current capacity ratios.

Conductor Size (Al Wire)

CMILS AWG mm2 ClassNo. ofWires

No. ofWiresin mm in mm

Nominal Dia. Nominal Dia.Aluminum Aluminum-clad Steel

kips(1000 lbf)

kN lb/10000ft kg/km

Stranding Rated Strength Linear Density

666,600636,000636,000636,000636,000636,000636,000605,000605,000605,000605,000556,500556,500556,500556,500477,000477,000477,000477,000397,500397,500397,500397,500336,400336,400336,400300,000266,800266,800211,600211,300203,200190,800176,900167,800159,000

337.8322.3322.3322.3322.3322.3322.3306.6306.6306.6306.6282.0282.0282.0282.0241.7241.7241.7241.7201.4201.4201.4201.4170.5170.5170.5152.0135.2135.2107.2107.1103.0

96.6889.6485.0280.57

AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA

AA, AAA(+)AA(+)AA(+)AA(+)AA, AAA(+)

24303026243618303026243026241830262418302624183026182626186

121612126

12

0.16670.14560.14560.15640.18280.13290.18800.14200.14200.15250.15880.13620.14830.15230.17580.12610.13540.14100.16280.11510.12360.12870.14860.10590.11370.13670.10740.10130.12170.18780.13270.11270.12610.12140.16720.1151

4.2343.6983.6983.9734.1353.3764.7753.6073.6073.8734.0343.4593.7163.8684.4653.2033.4393.5814.1352.9243.1393.2693.7742.6902.8883.4722.7282.5733.0914.7703.3712.8633.2033.0844.2472.924

719

77711

1977777717771777177177117

197717

0.11110.08740.14560.12160.10850.13290.18800.08520.14200.11860.10590.13620.11380.10150.17580.12610.10530.09400.16280.11510.09610.08580.14860.10590.08840.13670.08350.07880.12170.18780.13270.09770.12610.12140.16720.1151

2.8222.2203.6983.0892.7563.3764.7752.1643.6073.0122.6903.4592.8912.5784.4653.2032.6752.3884.1352.9242.4412.1793.7742.6902.2453.4722.1212.0023.0914.7703.3712.4823.2033.0844.2472.924

23.129.929.324.822.013.615.028.528.423.621.026.821.919.313.223.418.916.711.519.615.814.1

9.7816.713.5

8.5412.110.8

6.827.69

19.827.118.316.9

6.3015.3

103133130110

98.060.666.8

126.6126105

93.3119

97.585.758.9

10484.374.351.087.470.262.543.574.560.038.054.048.030.334.288.0

12081.375.428.068.0

823928935832785636676883889791747818728687591701624589507584520491422495440357392349283277477601431399219359

1,2241,3811,3911,2381,168

9461,0051,3131,3231,1781,1111,2171,0841,022

8791,043

928876754869773730628736654532584520421411709894641594326534

00000000000000000000000000

(Table 30)

29TAIHAN Overhead Electrical Aluminum Conductors

Page 30: 0512 AL Conductor

Notes : Class AA - For bare conductors usually used in overhead lines.Class A - For conductors to be covered with weather-resistant materials.(+) : Indicates conductors with high strength to current capacity ratios.

Conductor Size (Al Wire)

CMILS AWG mm2 ClassNo. ofWires

No. ofWiresin mm in mm

Nominal Dia. Nominal Dia.Aluminum Aluminum-clad Steel

kips(1000 lbf)

kN lb/10000ft kg/km

Stranding Rated Strength Linear Density

152,500141,300134,600133,100121,000112,100110,800105,600101,80099,83095,91088,84083,69080,00079,13076,08070,48066,36066,36064,92062,77060,34055,89052,62051,50049,78047,85044,32041,74041,74040,84039,47037,95035,15032,39031,30025,690

77.2771.6068.2067.4461.3156.8056.1453.5151.5850.5848.6045.0242.4140.5440.1038.5535.7133.6233.6232.8931.8130.5728.3226.6626.1025.2224.2522.4621.1521.1520.6920.0019.2317.8116.4115.8613.02

AA(+)AA(+)AA(+)AA,AAA(+)AA(+)AA(+)AA,AAA(+)AA(+)AA(+)AA(+)AA,AAA(+)AA(+)AA(+)AA(+)AA,AAA,AAA(+)AA(+)AA(+)AA(+)

AAA(+)AA(+)AA(+)AA(+)AA,AAA,AAA(+)AA(+)AA(+)AA(+)AA(+)AA(+)AA(+)

54

12654

126

123546835476235462354762354232

0.17470.18800.10590.14890.15560.16740.09610.13270.09210.18240.13850.14900.11810.10000.16240.12340.13270.09740.10520.18020.14460.10990.11820.09370.16050.12880.09780.10530.07720.08340.14290.11470.08710.09370.12730.10220.1133

4.4374.7752.6903.7823.9524.2522.4413.3712.3394.6333.5183.7853.0002.5404.1253.1343.3712.4742.6724.5773.6732.7913.0022.3804.0773.2722.4842.6751.9612.1183.6302.9132.2122.3803.2332.5962.878

2371237174231142311542315423115423545

0.17470.18800.10590.14890.15560.16740.09610.13270.09210.18240.13850.14900.11810.16700.16240.12340.13270.12990.10520.18020.14460.10990.11820.09370.16050.12880.09780.10530.10290.08340.14290.11470.08710.09370.12730.10220.1133

4.4374.7752.6903.7823.9524.2522.4413.3712.3394.6333.5183.7853.0004.2424.1253.1343.3713.2992.6724.5773.6732.7913.0022.3804.0773.2722.4842.6752.6142.1183.6302.9132.2122.3803.2332.5962.878

9.6614.213.0

5.138.03

11.910.8

4.259.91

16.46.589.683.454.89

13.85.458.103.512.76

19.511.2

4.376.602.23

16.59.693.505.262.281.78

13.57.722.794.19

11.36.138.96

43.062.957.822.835.752.748.018.944.172.729.343.015.321.761.224.336.015.612.386.950.019.429.4

9.9273.343.115.623.410.1

7.9359.934.312.418.650.327.339.9

281373304174223296250138230395177234109138313140186100

86.843024811114769341197

88.0117

62.754.5

270156

69.892.6

215124170

41855545225933244037220534258826334816320546620927614912964036916521910250829313117493.381.1

402232104138319185253

00000000000000000000001111122222233333444444444

(Table 30)

30 Overhead Electrical Aluminum Conductors TAIHAN

Page 31: 0512 AL Conductor

Stranded Aluminum-clad Steel ConductorAWS

AST

MA

NSI

IEC

BSAS

CSA

DIN

KSJI

SKE

PCO

TEC

ApplicationThis standard covers stranded aluminum-clad steel conductors to beused mainly for overhead ground wire.

ConstructionStranded aluminum-clad steel conductor

StandardsConforms to ASTM B 416-93

Coefficient of linear expansion 0.0000072/ 0.0000126/Final modulus of elasticity 23,000,000psi(160GPa)Temperature coefficient of resistance 0.0020/ 0.0036/Conductivity 20.3%

No. andSize ofWires

Min.BreakingStrength

(lb)

NominalDia.

(in)

No. and Dia. ofIndividual Wires Linear Density

Max.Resistance

( /1000ft, 20 )

NominalCross Section

Number(No.)

Nominal Dia.(in)

lb/1000ft lb/mile CMILS sq in

37 No. 5AWG37 No. 6AWG37 No. 7AWG37 No. 8AWG37 No. 9AWG37 No.10AWG19 No. 5AWG19 No. 6AWG19 No. 7AWG19 No. 8AWG19 No. 9AWG19 No.10AWG7 No. 5AWG7 No. 6AWG7 No. 7AWG7 No. 8AWG7 No. 9AWG7 No.10AWG7 No.11AWG7 No.12AWG3 No. 5AWG3 No. 6AWG3 No. 7AWG3 No. 8AWG3 No. 9AWG3 No.10AWG

373737373737191919191919

77777777333333

0.18190.16200.14430.12850.11440.10190.18190.16200.14430.12850.11440.10190.18190.16200.14430.12850.11440.10190.09070.08080.18190.16200.14430.12850.11440.1019

1.271.131.010.8990.8010.7130.9100.8100.7210.6420.5720.5090.5460.4860.4330.3850.3430.3060.2720.2420.3920.3490.3110.2770.2470.220

142,800120,200100,700

84,20066,77052,95073,35061,70051,73043,24034,29027,19027,03022,73019,06015,93012,63010,020

7,9456,301

12,23010,280

8,6217,2065,7154,532

2,8022,2221,7621,3981,108

879.01,4301,134

899.5713.5565.8448.7524.9416.3330.0261.8207.6164.7130.6103.6224.5178.1141.2112.0

88.8170.43

14,80011,730

9,3057,3795,8524,6417,5525,9904,7503,7672,9872,3692,7722,1981,7431,3821,096

869.4689.4546.8

1,186.0940.2745.6591.3468.9371.8

0.042470.053560.067540.085160.10740.13540.082240.10370.13080.16490.20790.26220.22640.28030.35350.44580.56210.70880.89381.1270.51770.65280.82321.0381.3091.651

1,225,000971,300770,300610,900484,400384,200628,900498,800395,500313,700248,800197,300231,700183,800145,700115,600

91,65072,68057,59045,71099,31078,75062,45049,53039,28031,150

0.96190.76290.60500.47980.38050.30170.49400.39170.31070.24640.19540.15490.18200.14430.11450.090770.071980.057080.045230.035900.078000.061850.049050.038900.030850.02446

(Table 31)

Aluminum

Steel

31TAIHAN Overhead Electrical Aluminum Conductors

Page 32: 0512 AL Conductor

Hard-drawn Aluminum Wires for Electric PurposesAL-ALLOY

Diameter Min. Tensile Strength

Individual Tests(%)

Toleranceon Dia.

( %, or in)

Min. Elongationin 10 in or250mm

inksi MPa ksi MPa

mmAverage for a Lot Individual Tests

0.1878 to 0.13280.1327 to 0.0612

4.770 to 3.3733.371 to 1.554

1%0.0010 in

4648

317331

4446

303317

3.03.0

(Table 32)Tensile Requirements

MaterialVolume

Conductivity(% IACS) cmil/ft mm2/m in cm

(Table 33)Equivalent Resistivity Values at 20°C(68°F)Resistivity Constants

Volume

CopperAluminumAluminumAluminum

10061.053.552.5

10.37117.00219.38519.755

0.0172410.0282650.0322270.32841

0.678791.11281.26871.2929

1.72412.82653.22273.2841

ApplicationThis standard covers aluminum-alloy(hard:solution, heat-treated, coldworked, and artificially aged) round wires for electrical purposes to beused mainly as component wires of Al-alloy stranded cables and Al-alloy cables steel reinforced.

ConstructionSingle aluminum-alloy conductor

StandardsConforms to ASTM B 398-97

32 Overhead Electrical Aluminum Conductors TAIHAN

Page 33: 0512 AL Conductor

Stranded Aluminum-alloy 6201-T81 ConductorsAAAC

AST

MA

NSI

IEC

BSAS

CSA

DIN

KSJI

SKE

PCO

TEC

ApplicationThis standard covers stranded aluminum-alloy 6201-T81 conductorswhich could high tensile load to be used mainly for overheaddistribution wire.

ConstructionStranded aluminum-alloy conductor

StandardsConforms to ASTM B 399-97

Notes : Class AA - For bare conductors usually used in overhead lines.Class A - For conductors to be covered with weather-resistant materials.

CodeWord

CMILS mm2

CMILSA AWG mm2

ConductorSize

Approx. Aluminum1350 Size having

Equivalent Resistance

Size and Stranding ofACSR with Equal Dia.

Required Construction WeightRated

StrengthResis-tance

Size CMILSA AWG kg/km kips kNClassmm2

in mm

Strand-ing

No. ofWires

lb/1000ft

Dia. of Wires ( /1000ft,20 )

-----GreelyFlintElginDarienCairoCantonButteAllianceAmherstAnaheimAzusaAmesAltonAkron

1,439,2001,348,8001,259,6001,165,1001,077,400927,200740,800652,400559,500465,400394,500312,800246,900195,700155,400123,300

77,47048,69030,580

729.2683.4638.2590.3545.9469.8375.4330.6283.5235.8199.9158.5125.1

99.278.762.539.324.715.5

0000000000246

644.5604.2564.0523.7483.4402.8322.3282.0241.7201.4170.5135.2107.2

85.067.453.533.621.113.3

1,272,0001,192,5001,113,0001,033,500954,000795,000636,000556,500477,000397,500336,400266,800211,600167,800133,100105,60066,36041,74026,240

0000000000246

644.5604.2564.0523.7483.4402.8322.3282.0241.7201.4170.5135.2107.2

85.067.453.533.621.113.3

54/754/754/754/754/726/726/726/726/726/726/726/7

6/16/16/16/16/16/16/1

616161616137371919191919

7777777

0.15360.14870.14370.13820.13290.15830.14150.18530.17160.15650.14410.12830.18780.16720.14900.13270.10520.08340.0661

3.903.783.653.513.384.023.594.714.363.983.663.264.774.253.783.372.672.121.68

AAAAAAAAAAAAAAAAAAAA

AA, AA

AAAA, AAA, AAA, AAA, A

AA

1,3421,2581,1751,0861,005

864.6690.8608.3521.7433.9367.9291.6230.2182.5144.9114.972.2445.4028.52

1,9971,8721,7481,6171,4951,2871,028

905.2776.3645.7547.4434.0342.6271.5215.6171.0107.567.5642.44

46.843.941.037.935.030.524.421.918.815.613.311.0

8.566.795.394.462.801.761.11

208195182169156136108

97.583.669.659.048.838.130.224.019.812.57.844.92

0.01400.01490.01600.01730.01870.02170.02720.03090.03600.04330.05110.06440.08160.103 0.1300.1630.2600.4140.659

1,272,0001,192,5001,113,0001,033,500954,000795,000636,000556,500477,000397,500336,400266,800211,600167,800133,100105,60066,36041,74026,240

(Table 34)

33TAIHAN Overhead Electrical Aluminum Conductors

Page 34: 0512 AL Conductor

High-strength Zinc-coated Steel Core Wire for Aluminum and Aluminum-alloy Conductors, Steel ReinforcedH.S-ACSR

Note : The above sizes are those commonly used.

ApplicationThis standard covers round, high-stength, zinc-coated, steel core wirewith class A zinc coating used for mechanical reinforcement in themanufacture of special Al and Al-alloy conductors, steel reinforced.

ConstructionThe center wire or wires are of high-strength galvanized steel and theouter layer or layers of special aluminum.

StandardsConforms to ASTM B 606-93

ACSR CopperEquivalent

(MCM or AWG)

No. and Dia. of Strands

(in)

Diameter

(in)Cross Section

Total

sq in Al StCompleteConductor

SteelCore

Aluminum

sq inMCM or AWG

CodeWord

GrousePetrelMinorcaLeghornGuineaDotterelDorkingBrahmaCochin

80101.8110.8134.6159176.9190.8203.2211.3

0.06280.08000.08700.10570.12490.13890.14990.15960.1660

0.08470.12660.13780.16740.19770.21990.23730.30200.2628

50.3164.1669.784.6

100111.2120.0127.8132.9

0.3670.4610.4810.5300.5760.6070.6310.7140.664

0.16700.27630.28830.31770.34530.36420.37830.48850.3981

8 0.100012 0.092112 0.096112 0.105912 0.115112 0.121412 0.126116 0.112712 0.1327

1 0.16707 0.09217 0.09617 0.10597 0.11517 0.12147 0.1261

19 0.09777 0.1327

(Table 35)

Weight(pound) Total Weight(%)

Ultimate Strength (pound)Zinc-coated Core

CalculatedResistance

at 20°C(68°F)

( /1000ft)

Per 1000ft Per mileCodeWord

Al Total Al Total Al StStandardWeightCoating

Class BCoating

Class CCoating

GrousePetrelMinorcaLeghornGuineaDotterelDorkingBrahmaCochin

75.196.0

104.5127.0150.0166.9180.0191.7199.3

149.0254.1276.6336.0396.8441.5476.3676.6527.5

397507552671792881950

1,0121,052

7871,3421,6401,7742,0952,3312,5253,5732,785

50.437.837.837.837.837.837.828.337.8

49.662.262.262.262.262.262.271.762.2

5,2009,860

10,73012,92015,20016,40017,73027,50019,640

4,6559,615

10,48012,62014,85015,64016,86026,80018,700

4,5509,385

10,22012,31014,88014,83016,00026,10017,700

0.2170.1710.1570.1290.1100.09850.09130.07230.0825

(Table 36)

High-strengthGalvanized steel

Aluminum conductor

34 Overhead Electrical Aluminum Conductors TAIHAN

Page 35: 0512 AL Conductor

“EC” Grade Aluminum Conductor Constructions, Weather-resistant Wire and CableHAL-OC

AST

MA

NSI

IEC

BSAS

CSA

DIN

KSJI

SKE

PCO

TEC

ApplicationThis standard covers HAL-OC(for use in 6,600 volts circuits) to be usedas weather-resistant wire and cable for the distribution of electricalenergy under the normal conditions of overhead line service.

ConstructionSolid or stranded hard-drawn aluminum conductor and polyethylenecross linked polyethylene insulation

StandardsConforms to ANSI C 8.35-1975, ICEA S-70-547

Add “HD” to code word to designated high-density polyethylene covering, or “XLPE” to designate cross-linked thermosetting polyethylene covering.

Code WordAWG or MCM

CMILS mm2

Cross Sectional Area No. of Wiresmils mm

Conductor Covering Thickness

CumquatApplePlumPearApricotCherryPeachNectarineQuinceHawOrangeIronwoodFigLemonOlivePomegranateSassafrasCatalpaMulberrySilverbeltBasswoodSycamoreAnonaCrabappleChinquapinGinkgoMollesAshSumacHuckleberryTupeloPaw PawTangerineBreadfruitPersimmonGrapefruitMango

86644221

1/01/02/0 2/0 3/03/04/04/0

250250266.8266.8300300336.4336.4350350397.5400450477500556636636795

1,033.51,590

16,51026,24026,24041,74041,74066,36066,36083,690

105,600105,600133,100133,100167,800167,800211,600211,600

8.36713.3013.3021.1521.1533.6233.6242.4153.4953.4967.4367.4385.0185.01

107.2107.2127127135135152152170170177177201203228242253282322322403523806

SolidSolid

7Solid

7Solid

777

197

197

197

19191919191919191919191919373737373761616161

303030303045454560606060606060606075607560756075607575757575757595959595

110

0.760.760.760.760.761.141.141.141.521.521.521.521.521.521.521.521.521.901.521.901.521.901.521.901.521.901.901.901.901.901.901.902.412.412.412.412.79

(Table 37)

Aluminum conductor

XLPE insulation

35TAIHAN Overhead Electrical Aluminum Conductors

Page 36: 0512 AL Conductor

Aluminum, Steel-reinforced(ACSR) Conductor Weather-resistant Insulation WiresACSR/OC

ApplicationThis standard covers ACSR-OC(for use in 6,600 volts circuits) to beused as weather-resistant cable for the distribution of electrical energyunder the normal conditions of overhead line service.

ConstructionAluminum, steel-reinforced conductor and polyethylene or cross-linkedpolyethylene insulation

StandardsConforms to ANSI C 8.35-1975, ICEA S-70-547

Galvanized steel

XLPE insulation

Aluminum conductor

Code WordAWG or MCM

CMILS mm2

Aluminum Cross Sectional Area Strands Al/Stmils mm

Conductor Covering Thickness

WalnutAcornButternutHickoryHazelnutPignutBeechChestnutAlmondPecanCottonwoodFilbertChokeberryBuckeyeGumwoodHackberryRedbudMockernutAspen

65443221

1/02/02/03/03/04/04/0

266.8266.8336.4336.4

26,24033,09041,74041,74052,62066,36066,36083,690

105,600133,100133,100167,800167,800211,600211,600

13.3016.7721.1521.1526.6733.6233.6242.4153.4967.4367.4385.0185.01

107.2107.2135135170170

6/16/16/17/16/16/17/16/16/16/16/16/16/16/16/1

18/118/118/118/1

30303030454545456060756075607560756075

0.760.760.760.761.141.141.141.141.521.521.901.521.901.521.901.521.901.521.90

(Table 38)

Add “HD” to code word to designated high-density polyethylene covering, or “XLPE” to designate cross-linked thermosetting polyolefin covering.

36 Overhead Electrical Aluminum Conductors TAIHAN

Page 37: 0512 AL Conductor

AST

MA

NSI

IEC

BSAS

CSA

DIN

KSJI

SKE

PCO

TEC

Electrical Conductors, Covered Line Wire and Multiplex Types Weather-resistant Line Wire

Note : Items shown in colored type are normally used.

(Table 39)

POLYETHYLENE TYPE

Al Total

Code Word CMILS or AWG StrandingCover Thickness

64th(in)

Nominal Weight(pound/1000ft)

Length per Reel

(ft)

Solid Aluminum ConductorApplePearCherry

642

111

223

24.238.461.1

31.748.079.2

12,0008,5005,000

(Table 42)

CROSS-LINKED POLYETHYLENE(XLPE) TYPE

Al Total

Code Word CMILS or AWG StrandingCover Thickness

64th(in)

Nominal Weight(pound/1000ft)

Length per Reel

(ft)

Solid Aluminum ConductorApple/XLPEPear/XLPECherry/XLPE

642

111

223

24.238.461.1

345083

12,0008,5005,000

(Table 41)ACSRWalnutButternutHickoryPignutBeechChestnutAlmondPecanFilbertBuckeyeHackberry

644221

1/02/03/04/0

266,800

6/16/17/16/17/16/16/16/16/16/1

18/1

22233344444

24.539.039.062.062.078.298.6

124.3156.8197.7250.4

47.572.082.0

119.0135.0146.0191.0235.0290.0359.0357.0

8,0005,1006,0006,4005,6005,1004,0003,2003,8003,0002,400

(Table 43)Stranded Aluminum ConductorPlum/XLPEApricot/XLPEPeach/XLPENectarine/XLPEQuince/XLPEOrange/XLPEFig/XLPEOlive/XLPEPomegranate/XLPE

6421

1/02/03/04/04/0

77777777

19

223344444

24.639.262.378.599.1

124.9157.5198.6198.6

375593

113150183223274266

9,4007,0007,5006,0004,7003,7504,4003,5003,800

(Table 40)Stranded Aluminum ConductorPlumApricotPeachNectarineQuinceOrangeFigOlivePomegranateMulberryAnonaCrabappleMollesHuckleberryPaw PawBraedfruitPersimmonGrapefruit

6421

1/02/03/04/04/0

266,800336,400336,400397,500477,000556,500636,000795,000

1,033,500

77777777

19191919193737616161

223344444445555666

24.639.262.378.599.1

124.9157.5198.6198.6250.4315.8315.8372.5447.8522.4597.0746.3970.1

35.053.387.4

107.0140.0172.0211.0260.0255.0315.0390.0404.0471.0550.0635.0740.0900.0

1,150.0

9,4007,0007,5006,0004,7003,7504,4003,5003,8003,0002,4002,0002,0003,3002,8002,5002,2001,700

37TAIHAN Overhead Electrical Aluminum Conductors

Page 38: 0512 AL Conductor

Electrical Conductors, Covered Line Wire and Multiplex Types Self-supporting Secondary and Service Drop Cable

(Table 44)

POLYETHYLENE DUPLEX TYPE

Code WordAWG Stranding

AWG Stranding Al TotalInsulation

Thickness 64th

Phase Conductors Bare NeutralMessenger

Nominal Weight(lb/1000ft)

Lengthper Reel

(ft)

All-aluminum Neutral MessengerPekingeseCollieDachshundSpanielDobermanMalemute

66442

1/0

17177

19

333334

66442

1/0

777777

49497878

125198

636695

100152244

3,0002,8002,2002,0002,4001,500

(Table 45)ACSR Neutral MessengerSetterShepherdEskimoTerrierChowBull

66442

1/0

17177

19

333334

66442

1/0

6/16/16/16/16/16/1

49497778

124198

7578

114118181289

3,0002,8002,2002,0002,4001,500

(Table 46)

CROSS-LINKED POLYETHYLENE(XLPE) DUPLEX TYPE

Code WordAWG Stranding

AWG Stranding Al TotalInsulation

Thickness 64th

Phase Conductors Bare NeutralMessenger

Nominal Weight(lb/1000ft)

Lengthper Reel

(ft)

All-aluminum Neutral MessengerPekingese/XLPECollie/XLPEDachshund/XLPESpaniel/XLPEDoberman/XLPEMalemute/XLPE

66442

1/0

17177

19

333334

66442

1/0

777777

49497878

125198

646896

103156246

3,0002,8002,2002,0002,4001,500

(Table 47)ACSR Neutral MessengerSetter/XLPEShepherd/XLPEEskimo/XLPETerrier/XLPEChow/XLPEBull/XLPE

66442

1/0

17177

19

333334

66442

1/0

6/16/16/16/16/16/1

49497778

124198

7580

114121185282

3,0002,8002,2002,0002,4001,500

Note : Items shown in colored type are normally used.

38 Overhead Electrical Aluminum Conductors TAIHAN

Page 39: 0512 AL Conductor

AST

MA

NSI

IEC

BSAS

CSA

DIN

KSJI

SKE

PCO

TEC

Electrical Conductors, Covered Line Wire and Multiplex Types Self-supporting Secondary and Service Drop Cable

(Table 48)

POLYETHYLENE TRIPLEX TYPE

Code WordAWG Stranding

AWG Stranding Al TotalInsulation

Thickness 64th

Phase Conductors Bare NeutralMessenger

Nominal Weight(lb/1000ft)

Lengthper Reel

(ft)

All-aluminum Neutral Messenger6442

1/01/02/02/03/04/0

11777

197

191919

3333444444

6442

1/01/02/02/03/04/0

77777777

1919

73116118187297297375375473596

100151161240395390486478583722

2,5001,7001,5001,8001,2001,2001,5001,5001,3001,000

HaiotisFususOysterClamMurexPurpuraNassaTrophonMelitaPortunus

(Table 49)ACSR Neutral MessengerPaludinaVolutaWhelkPeriwinkleConchNeritinaCeniaRuncinaTritonMursiaZuzara

66442

1/01/02/02/03/04/0

171777

197

191919

33333444444

6644 2

1/01/02/02/03/04/0

6/16/16/16/16/16/16/16/16/16/16/1

7374

116118187297297374374472596

112120170180270431426544536657814

2,5002,0001,7001,5001,8001,2001,2001,5001,5001,3001,000

(Table 50)

CROSS-LINKED POLYETHYLENE(XLPE) TRIPLEX TYPE

Code WordAWG Stranding

AWG Stranding Al TotalInsulation

Thickness 64th

Phase Conductors Bare NeutralMessenger

Nominal Weight(lb/1000ft)

Lengthper Reel

(ft)

All-aluminum Neutral Messenger6442

1/01/02/02/03/04/0

11777

197

191919

3333444444

6442

1/01/02/02/03/04/0

77777777

1919

73116118187297297375375473596

103154166249400393480483595734

2,5001,7001,5001,8001,2001,2001,5001,5001,3001,000

Haiotis/XLPEFusus/XLPEOyster/XLPEClam/XLPEMurex/XLPEPurpura/XLPENassa/XLPETrophon/XLPEMelita/XLPEPortunus/XLPE

(Table 51)ACSR Neutral MessengerPaludina/XLPEVoluta/XLPEWhelk/XLPEPeriwinkle/XLPEConch/XLPENeritina/XLPECenia/XLPERuncina/XLPETriton/XLPEMursia/XLPEZuzara/XLPE

66442

1/01/02/02/03/04/0

171777

197

191919

33333444444

6644 2

1/01/02/02/03/04/0

6/16/16/16/16/16/16/16/16/16/16/1

7374

116118187297297374374472596

115124172184278446439498541668827

2,5002,0001,7001,5001,8001,2001,2001,5001,5001,3001,000

39TAIHAN Overhead Electrical Aluminum Conductors

Page 40: 0512 AL Conductor

Electrical Conductors, Covered Line Wire and Multiplex Types Self-supporting Secondary and Service Drop Cable

(Table 52)

POLYETHYLENE QUADRUPLEX TYPE

Code WordAWG Stranding

AWG Stranding Al TotalInsulation

Thickness 64th

Phase Conductors Bare NeutralMessenger

Nominal Weight(lb/1000ft)

Lengthper Reel

(ft)

All-aluminum Neutral MessengerClydesdalePintoMustangCriolloPercheronHanoverionOldenburg

442

1/02/03/04/0

177

19191919

3334444

442

1/02/03/04/0

77777

1919

154157249396500630795

207220330535655806993

1,7001,5001,8001,1001,5001,3001,000

(Table 53)ACSR Neutral MessengerMorochucaCholaMorganHackneyPalominoCostenaGrulloSuffolkAppaloosa

66442

1/02/03/04/0

17177

19191919

333334444

66442

1/02/03/04/0

6/16/16/16/16/16/16/16/16/1

9798

154157249396499629794

151163225245370580715879

1,087

2,5002,0001,7001,5001,8001,1001,5001,3001,000

(Table 54)

CROSS-LINKED POLYETHYLENE(XLPE) QUADRUPLEX TYPE

Code WordAWG Stranding

AWG Stranding Al TotalInsulation

Thickness 64th

Phase Conductors Bare NeutralMessenger

Nominal Weight(lb/1000ft)

Lengthper Reel

(ft)

All-aluminum Neutral MessengerClydesdale/XLPEPinto/XLPEMustang/XLPECriollo/XLPEPercheron/XLPEHanoverion/XLPEOldenburg/XLPE

442

1/02/03/04/0

177

19191919

3334444

442

1/02/03/04/0

77777

1919

154157249396500630795

202219329521641791977

1,7001,5001,8001,1001,5001,3001,000

(Table 55)ACSR Neutral MessengerMorochuca/XLPEChola/XLPEMorgan/XLPEHackney/XLPEPalomino/XLPECostena/XLPEGrullo/XLPESuffolk/XLPEAppaloosa/XLPE

66442

1/02/03/04/0

17177

19191919

333334444

66442

1/02/03/04/0

6/16/16/16/16/16/16/16/16/1

9798

154157249396499629794

148159221238359568700864

1,070

2,5002,0001,7001,5001,8001,1001,5001,3001,000

One phase wire identified with ridges.

40 Overhead Electrical Aluminum Conductors TAIHAN

Page 41: 0512 AL Conductor

International Electrotechnical Commission IEC

41TAIHAN Overhead Electrical Aluminum Conductors

Page 42: 0512 AL Conductor

Stranded Hard-drawn Aluminum ConductorAAC

ApplicationThis standard covers stranded hard-drawn circular aluminumconductors to be used mainly for overhead distribution wires, overheadfeeder.

ConstructionStranded hard-drawn aluminum conductors

StandardsConforms to IEC 1089-91

CodeNumber

(No.)

Area

(mm2)

No. ofWires(No.)

LinearMass

(kg/km)

RatedStrength

(kN)

D.C.Resistance

( / km)Wire Conductor

Diameter(mm)

1016254063

100125160200250315400450500560630710800900

1,0001,1201,2501,4001,500

1016254063

100125160200250315400450500560630710800900

1,0001,1201,2501,4001,500

77777

19191919193737373737616161616191919191

1.351.712.132.703.392.592.893.273.664.093.293.713.944.154.393.633.854.094.334.573.964.184.434.58

4.055.126.408.09

10.212.914.516.418.320.523.026.027.529.030.732.634.636.839.041.143.546.048.750.4

27.443.868.4

109.4172.3274.8343.6439.8549.7687.1867.9

1,102.01,239.81,377.61,542.91,738.31,959.12,207.42,483.32,759.23,093.53,452.63,866.94,143.1

1.953.044.506.80

10.3917.0021.2526.4032.0040.0051.9764.0072.0080.0089.60

100.80113.60128.00144.00160.00179.20200.00224.00240.00

2.86331.78961.14530.71580.45450.28770.23020.17980.14390.11510.09160.07210.06410.05770.05150.04580.04070.03610.03210.02890.02580.02310.02070.0193

(Table 56)

42 Overhead Electrical Aluminum Conductors TAIHAN

Page 43: 0512 AL Conductor

Stranded Aluminum-alloy ConductorsAAAC

ASTM

ANSI

IEC

BSAS

CSA

DIN

KSJI

SKE

PCO

TEC

CodeNumber

(No.)

Area

(mm2)

No. ofWires(No.)

LinearMass

(kg/km)

RatedStrength

(kN)

D.C.Resistance

( / km)Wire Conductor

Diameter(mm)

16254063

100125160200250315400450500560630710800900

1,0001,120

18.629.046.573.2116145186232290366465523581651732825930

1,0461,1621,301

7777

19191919193737373761616161919191

1.842.302.913.652.793.123.533.954.413.554.004.244.473.693.914.154.403.834.034.27

5.526.908.72

10.914.015.617.619.722.124.828.029.731.333.235.237.339.642.144.446.9

50.879.5

127.1200.2319.3399.2511.0638.7798.4

1,008.41,280.51,440.51,600.61,795.32,019.82,276.22,564.82,888.33,209.33,594.4

6.049.44

15.1023.0637.7647.2058.5673.2091.50

115.29146.40164.70183.00204.96230.58259.86292.80329.40366.00409.92

1.78961.14530.71580.45450.28770.23020.17980.14390.11510.09160.07210.06410.05770.05160.04580.04070.03610.03210.02890.0258

(Table 57)

ApplicationThis standard covers stranded aluminum-alloy conductors of thealuminum-magnesium-silicon type which could high tensile load to beused mainly for overhead distribution wires.

ConstructionStranded aluminum-alloy conductor

StandardsConforms to IEC 1089-91

43TAIHAN Overhead Electrical Aluminum Conductors

Page 44: 0512 AL Conductor

Aluminum Conductors, Steel ReinforcedACSR

ApplicationThis standard covers aluminum stranded conductors steel reinforcedwhich could withstand high tensile load to be used mainly for overheadtransmission lines, overhead distribution lines.

ConstructionThe center wire or wires are of steel and the outer layer or layers ofaluminum.

StandardsConforms to IEC 1089-91

CodeNumber

SteelRatio

Areas(mm2)

No. of Wires(No.)

Wire Dia.(mm)

Diameter(mm)

LinearMass

RatedStrength

D.C.Resistance

(No.) (%) Al St Total Al St Al St Core (kg/km) (kN) ( / km)Conductor16254063

100125125160160200200250250315315400400450450500500560560630630710710800800800900900

1,0001,1201,1201,2501,250

1717171717

616

616

6161016

716

713

713

713

713

713

713

48

134844884

16254063

100125125160160200200250250315315400400450450500500560560630630710710800800800900900

1,0001,1201,1201,2501,250

2.674.176.67

10.516.7

6.9420.4

8.8926.111.132.624.640.721.851.327.751.931.158.334.664.838.770.943.679.849.189.934.666.7

10138.975.043.247.391.2

10252.8

18.729.246.773.5

117132145169186211233275291337366428452481508535565599631674710759800835867901939975

1,0431,1671,2111,3521,303

66666

1826182618262226452645544554455445544554455472845472847272848472

1111117171777777777777

197

197

1977

19777

19191919

1.842.302.913.664.612.972.473.362.803.763.133.803.502.993.933.363.073.573.263.763.433.983.634.223.854.484.093.763.484.343.993.694.214.454.124.354.70

1.842.302.913.664.612.971.923.362.183.762.432.112.721.993.052.243.072.383.262.513.432.652.182.812.312.992.452.513.482.612.663.692.801.782.472.611.88

1.842.302.913.664.612.975.773.366.533.767.306.348.165.979.166.739.217.149.777.52

10.37.96

10.98.44

11.68.96

12.37.52

10.413.0

7.9811.1

8.418.90

12.413.1

9.40

5.536.918.74

11.013.814.915.716.817.718.819.821.622.223.924.926.927.628.529.330.130.931.832.733.834.735.936.837.638.339.139.940.642.144.545.347.947.0

64.6100.9161.5254.4403.8397.9503.9509.3644.9636.7806.2880.6

1,007.71,039.61,269.71,320.11,510.31,485.21,699.11,650.21,887.91,848.22,103.42,079.22,366.32,343.22,666.82,480.22,732.73,004.92,790.23,074.23,100.33,464.93,811.54,253.93,867.1

6.089.13

14.4021.6334.3329.1745.6936.1857.6944.2270.1368.7287.6779.03

106.8398.36

123.04107.47138.42119.41153.80133.74172.59150.45191.77169.56216.12167.41205.33243.52188.33226.50209.26234.53283.17316.04261.75

1.79341.14780.71740.45550.28690.23040.23100.18000.18050.14400.14440.11540.11550.09170.09170.07220.07230.06420.06430.05780.05780.05160.05160.04590.04590.04070.04070.03610.03620.03620.03210.03220.02890.02580.02580.02320.0231

(Table 58)

Galvanized steel

Aluminum conductor

44 Overhead Electrical Aluminum Conductors TAIHAN

Page 45: 0512 AL Conductor

Aluminum-alloy Conductors, Extra-high Strength Steel ReinforcedAACSR/EST

ASTM

ANSI

IEC

BSAS

CSA

DIN

KSJI

SKE

PCO

TECApplication

This standard covers aluminum-alloy(aluminum-magnesium-silicontype) stranded conductors extra high strength steel with class 1 zinc-coating reinforced which could withstand extra high tensile load to beused mainly for overhead transmission lines, overhead distribution lines.

ConstructionThe center wire or wires are of extra-high strength galvanized steel andthe outer layer or layers of aluminum-alloy.

StandardsConforms to IEC 1089-91

CodeNumber

SteelRatio

Areas(mm2)

No. of Wires(No.)

Wire Dia.(mm)

Diameter(mm)

LinearMass

RatedStrength

D.C.Resistance

(No.) (%) Al St Total Al St Al St Core (kg/km) (kN) ( / km)Conductor16254063

100125125160160200200250250315315400400450450500500560560630630710710800800900900

1,0001,120

1717171766

166

166

161016

716

713

713

713

713

413

413

484888

18.629.046.573.2

116145145186186232232290290366366465465523523581581651651732732825825930930

1,0461,0461,1621,301

3.104.847.75

12.26.468.07

23.710.330.312.937.828.547.325.359.632.160.236.167.840.275.345.082.431.692.735.6

10440.277.545.287.194.6

106

21.733.954.285.4123153169196216245270319338391426497525559591621656696733764825861929970

1,0071,0911,1331,2571,407

6666

1818261826182622264526455445544554455472547254728472848484

1111117171777777777777

197

197

197777

1919

1.992.483.143.942.873.212.673.633.024.053.374.103.773.224.233.633.313.853.514.053.704.293.923.604.153.824.414.053.754.303.984.204.44

1.992.483.143.942.873.212.073.632.354.052.622.282.932.153.292.423.312.563.512.703.702.862.352.402.492.552.652.703.752.873.982.522.66

1.992.483.143.942.873.216.223.637.044.057.876.838.806.449.887.259.937.69

10.58.11

11.18.58

11.87.20

12.57.64

13.28.11

11.38.60

11.912.613.3

5.967.459.42

11.814.316.016.918.119.120.321.423.223.925.726.829.029.830.831.632.433.334.335.336.037.438.239.740.541.343.043.846.248.9

75.1117.3187.7295.6369.9462.3585.4591.8749.4739.8936.7

1,023.21,170.91,207.91,475.31,533.91,754.91,725.61,974.21,917.32,193.62,147.42,444.02,269.42,749.52,557.63,098.62,881.83,175.13,242.03,572.03,954.14,428.6

10.5316.2725.7939.4146.8658.3481.5072.40

103.1190.50

128.89131.72158.21155.64197.55191.71234.19215.67255.52239.63283.91268.39321.17275.18361.32310.12407.20349.43396.60393.11446.17499.40559.33

1.79341.14780.71740.45550.28800.23040.23100.18000.18050.14400.14440.11540.11550.09170.09170.07220.07230.06420.06430.05780.05780.05160.05160.04590.04590.04070.04070.03610.03620.03210.03220.02890.0258

(Table 59)

Extra-high strength galvanized steel

Aluminum-alloy conductor

45TAIHAN Overhead Electrical Aluminum Conductors

Page 46: 0512 AL Conductor

Taihan Electric Wire

opening up the happier

world and more enriched future

46 Overhead Electrical Aluminum Conductors TAIHAN

Page 47: 0512 AL Conductor

British Standards

Australian Standards

Canadian Standards Association

Deutsches Normen

BS

AS

CSA

DIN

47TAIHAN Overhead Electrical Aluminum Conductors

Page 48: 0512 AL Conductor

Stranded All-aluminum ConductorsAAC

Aluminum Wires Used in the Construction of Standard Aluminum Stranded Conductors

ApplicationThis standard covers all-aluminum stranded conductors to be usedmainly for overhead distribution wire, overhead feeders and buses.

ConstructionAll-aluminum stranded conductors

StandardsConforms to BS 215 : part 1/1970

CodeWord

NominalAluminum

Area(mm2)

EquivalentArea

(HDCC)(mm2)

Stranding& Wire

Dia.(mm)

Approx.Overall

Dia.(mm)

TotalArea

(mm2)

Weight

(kg/km)

NominalBreaking

Load(kgf)

Max. D.C.Resistance

( km, 20 ) Temperate Tropical

Rating(amps)

MidgeAphisGnatWeevilMosquitoLadybirdAntFlyBluebottleEarwigGrasshopperCleggWaspBeetleBeeCricketHornetCaterpillarChaferSpiderCockroachButterflyMothDroneLocustCentipedeMaybugScorpionCicadaTarantula

22-----

5060

----

100---

150-

200-

250300

---

400----

14.216.116.119.422.625.832.338.745.248.451.658.164.564.580.696.896.8

113.0129.0145.0161.0194.0226.0226.0258.0258.0290.0323.0387.0484.0

7/2.063/3.357/2.213/3.667/2.597/2.797/3.107/3.407/3.667/3.787/3.917/4.177/4.39

19/2.677/4.907/5.36

19/3.2519/3.5319/3.7819/3.9919/4.2219/4.6519/5.0037/3.5819/5.3637/3.7837/4.0937/4.2737/4.6537/5.23

6.187.26.67.97.88.49.3

10.211.011.411.712.513.1713.414.716.116.2517.718.920.021.123.2525.025.126.826.4628.629.932.636.6

23.3326.426.831.637.042.852.8363.5573.778.584.195.6

106.0106.6132.0157.9157.6186.0213.2236.9265.7322.7373.2373.3428.5415.2486.9529.5628.6794.8

64737386

101117145174202215230262290293361432434512587652731888

1,0271,0291,1791,1451,3421,4601,7332,191

408419468496617701846

1,0101,1581,2181,3031,4821,6321,7762,0832,4322,5192,9203,3043,6724,1204,9665,7485,8586,6016,4347,5478,1569,682

12,247

1.2271.0811.0680.90820.77310.66940.54190.45050.38840.36450.34050.29940.27020.26990.21690.18140.18250.15470.13490.12140.108300.089160.077090.077230.067140.068440.059210.054450.045870.03628

114139124147144159181199219227238256271274308342346380414439470528572572626619676710784899

7287789593

101112124132136141150158172175189190204215224232247256257263262268269266241

(Table 60)

No. of Wiresin Conductor Mass Electrical Resistance

Stranding Constants Practical(final) Modulus of Elasticity(hbar)

Coefficient of Linear(Expansion/ )

71937

7.09119.3437.74

0.14470.053570.02757

5,9005,6005,600

23.0 10-6

23.0 10-6

23.0 10-6

Standard Dia.

(mm)

Mass

(kg/km)

Standard Resistance

( /km,20 )

Min. Breaking Load for Standard Dia. Wire

(N)

Cross Sectional Area ofStandard Dia. Wire

(mm2)

1 2 3 4 5

2.063.103.253.403.784.224.394.65

3.3337.5488.2969.079

11.2213.9915.1416.98

9.00920.4022.4224.5430.3337.8140.9145.90

8.4803.7453.4073.1132.5192.0211.8671.664

6001,2501,3701,4901,8002,2402,4102,700

Note : These values are given for information only. 1 hbar=10MN/m2=10N/mm2

Note : The values given in columns 2 to 5 are given for information olny.

48 Overhead Electrical Aluminum Conductors TAIHAN

Page 49: 0512 AL Conductor

Aluminum Conductors, Steel ReinforcedACSR

ASTM

ANSI

IEC

BS

AS

CSA

DIN

KSJI

SKE

PCO

TEC

ApplicationThis standard covers aluminum stranded conductors steel reinforcedwhich could withstand high tensile load to be used mainly for overheadtransmission lines, overhead distribution lines.

ConstructionThe center wire or wires are of steel and the outer layer or layers ofaluminum.

StandardsConforms to BS 215 : part 2/1970

CodeWord

Equiv.Area

(HDCC)(mm2) Al St Al St Total Al St Total N kgf ( /km, 20 ) Temperate Tropical

Stranding and Wire Dia.

(mm)

OverallDia.

(mm)

Area

(mm2)

Weight

(kg/km)

NominalBreaking Load

Rating(amps)

Max. D.C.Resistance

NominalAl

Area(mm2)

MoleSquirrelGopherWeaselFoxFerretRabbitMinkSkunkBeavorHorseRaccoonOtterCatHareDogHyenaLeopardCoyoteCougarTigerWolfDingoLynxCaracalJaguarPantherLionBearBatangGoatSheepAntelopeBisonDeerZebraElkCamelMoose

--

2530

-4050

---

70----

100-----

150150175175200200

-250

-300

----

400---

6.512.916.119.422.625.832.338.738.745.245.248.451.658.164.564.564.580.780.780.780.796.897.9

113.0113.7130129145161194194226226226258258290290323

6/1.506/2.116/2.366/2.596/2.796/3.006/3.356/3.66

12/2.596/3.99

12/2.796/4.106/4.226/4.506/4.726/4.72 7/4.396/5.28

26/2.5418/3.0530/2.3630/2.5918/3.3530/2.7918/3.6118/3.8630/3.0030/3.1830/3.3518/4.7830/3.7130/3.9954/2.9754/3.0030/4.2754/3.1830/4.5054/3.3554/3.53

1/1.501/2.111/2.361/2.591/2.791/3.001/3.351/3.667/2.591/3.997/2.791/4.101/4.221/4.501/4.727/1.577/1.937/1.757/1.911/3.057/2.367/2.591/3.357/2.791/3.611/3.867/3.007/3.187/3.357/1.687/3.717/3.997/2.977/3.007/4.277/3.187/4.507/3.357/3.53

4.506.337.087.778.379.00

10.0510.9812.9511.9713.9512.3012.6613.5014.1614.1514.5715.8115.8915.2516.5218.1316.7519.5318.0519.3021.0022.2623.4524.1625.9727.9326.7327.0029.8928.6231.5030.1531.77

10.6220.9426.2431.6136.6642.4152.8863.1863.4874.8273.3779.2083.8895.40

105.0105.0105.8131.3132.1130.3131.1158.0158.7183.4184.3210.6212.0238.5264.0323.0324.3374.1373.1381.8429.3428.9477.0475.2528.7

1.773.494.375.276.117.078.81

10.5337.0312.4742.8013.2013.9815.9017.5013.5020.4418.8020.097.24

30.5936.888.80

42.7710.2411.6949.4955.6561.6015.5275.6787.2948.3749.49

100.2055.59

111.3061.6068.53

12.3924.4330.6236.8842.7749.4861.7073.71

100.5087.29116.20

92.4097.86

111.30122.50118.5126.2148.1152.2137.5161.7194.9167.5226.2194.5222.3261.5294.2325.6338.52400.0461.4421.5431.3529.5484.5588.3536.8597.2

29587287

101117145173175205203217230262288288290360365362362437437507507580586659730888896

1,0341,0321,0561,1861,1861,3181,3141,462

1427344148556982

29097

33510310912413710616013215726724028069

3358191

388436483121593684379388785435872483537

4385

106128149172214255465302538320339386425394450492522419602726506842588671974

1,0951,2131,0091,4891,7181,4111,4441,9711,6212,1901,7971,999

4,1007,9009,610

11,45013,20015,20018,35021,80053,10025,70061,20027,20028,70032,70036,00032,70040,90040,70046,40029,80058,00069,20035,70079,80041,00046,55092,250

100,600111,100

70,900135,700155,900118,200120,900178,500131,900198,200145,700161,100

418806980

1,1681,3461,5501,8712,2235,4152,6216,2412,7742,9273,3353,6713,3354,1714,1504,7323,0395,9147,0563,6408,1374,1814,7479,407

10,25811,329

7,24013,83815,89712,05312,32818,20213,45020,21114,85716,428

2.7021.3701.0930.90770.78270.67660.54260.45410.45650.38340.39360.36230.34210.30080.27330.27330.27120.21850.21870.22100.22040.18280.18150.15760.15630.136700.13630.12120.10950.08940.089100.077240.077470.075710.067310.067400.060580.060830.05468

67109126134147161185174246193268231240248273278287316311314323355349386383415421448481510542592588595639635679677763

556977849398

112103139110148131137145151153155167164168164162179178205197191195198165200197208208186202165192176

(Table 61)

Galvanized steel

Aluminum conductor

49TAIHAN Overhead Electrical Aluminum Conductors

Page 50: 0512 AL Conductor

Aluminum Conductors, Steel ReinforcedACSR

Notes : These values are given for information purpose only.1 hbar = 10 MN/m2 = 10 N/mm2

Aluminum Wires Used in the Construction of Standard AluminumConductors, Steel-reinforced

No. of Wires in Conductor(No.)

Al St Al

Mass ElectricalResistanceSt

Practical (final) Modulus of Elasticity

(hbar)

Coefficientof Linear

(Expansion/ )

Stranding Constants

66

12183054

177177

6.0916.091

12.2618.3430.6755.23

1.0007.0327.0321.0007.0327.032

0.16920.16920.085140.056600.034080.01894

7,9007,500

10,5006,6008,0006,900

19.1 10-6

19.8 10-6

15.3 10-6

21.2 10-6

17.8 10-6

19.3 10-6

Note : The values in column 2 to 5 are given for information only.BS 4565. “Galvanized steel wire for aluminum conductors, steel-reinforced.”

1 2 3 4 5

StandardDia.

(mm)

Cross Sectional Area ofStandard Dia. Wire

(mm2)

Mass

(kg/km)

StandardResistance

( /km,20 )

Min. Breaking Load forStandard Dia. Wire

(N)

2.362.592.793.003.183.353.613.864.72

4.3745.2696.1147.0697.9428.81410.2411.4017.50

11.8214.2416.5319.1121.4723.8227.6731.6347.30

6.4615.3654.6233.9993.5593.2072.7612.4151.615

770906

1,0301,1901,3101,4501,6601,8702,780

Steel Wires Used in the Construction of Standard Aluminum Conductors,Steel-reinforced

Note : The values in column 2 to 4 are given for information only.

1 2 3 4

StandardDia.

(mm)

Cross Sectional Area ofStandard Dia. Wire

(mm2)

Mass

(kg/km)

Min. Load at 1% Elongation forStandard Dia. Wire

(N)

1.572.362.592.793.003.183.353.613.86

1.9364.3745.2696.4147.0697.9428.814

10.2411.70

15.1034.1241.0947.6955.1361.9568.7579.8491.28

2,2804,9906,0106,5708,0608,7409,700

11,26012,870

50 Overhead Electrical Aluminum Conductors TAIHAN

Page 51: 0512 AL Conductor

Stranded All-aluminum ConductorsAAC

ASTM

ANSI

IEC

BS

AS

CSA

DIN

KSJI

SKE

PCO

TEC

ApplicationThis standard covers stranded hard-drawn circular aluminumconductors to be used mainly for overhead distribution wires, overheadfeeder.

ConstructionStranded hard-drawn aluminum conductors

StandardsConforms to AS 1531/1991

Notes : 1. The sectional area is the sum of the cross sectional areas of the relevant individual wires.2. For the basis of calculation of columns 4, 5, 6 and 7, see (AS 1531) Appendix A.

CodeWord

Stranding &Wire Dia.

(mm)

ApproxOverall Dia.

(mm)

SectionalArea

(mm2)

CalculatedEquivalent

Al Area(mm2)

Approx.Mass

(kg/km)

Min. CalculatedBreaking Load

(kN)

Calculated D.C.Resistance

( /km, 20 )

1 2 3 4 5 6 7

LeoLeonidsLibraMarsMercuryMoonNeptuneOrionPlutoSaturnSiriusTaurusTritonUranusUrsulaVenus

7/2.507/2.757/3.007/3.757/4.507/4.75

19/3.2519/3.5019/3.7537/3.0037/3.2519/4.7537/3.7561/3.2561/3.5061/3.75

7.508.259.00

11.313.514.316.317.518.821.022.823.826.329.331.533.8

34.3641.5849.4877.28

111.3124.0157.6182.8209.8261.6307.0336.7408.5506.1586.9673.4

33.941.148.976.3

110122154180206256301331400495574659

94.3113135211304339433503576721845924

1,1201,4001,6201,860

5.716.727.98

11.816.918.924.728.731.942.248.251.362.275.287.397.2

0.8330.6890.5790.3700.2580.2320.1830.1570.1370.1100.0940.08570.07060.05720.04930.0493

(Table 62)

51TAIHAN Overhead Electrical Aluminum Conductors

Page 52: 0512 AL Conductor

Aluminum Conductors, Galvanized Steel Reinforced (AS 3607/1989)ACSR/GZ

Notes : 1. The sectional area is the sum of the cross sectional areas of the relevant individual wires.2. For the basis of calculation of columns 5, 6, 7 and 8, see (AS 3607) Appendix A.

CodeWord

Al Galvanized St

Stranding and Wire Dia.(mm)

Approx.Overall Dia.

(mm)

SectionalArea

(mm2)

CalculatedEquiv. Al Area

(mm2)

Approx.Mass

(kg/km)

Min. CalculatedBreaking Load

(kN)

Calculated D.C.Resistance

( /km, 20 )

1 2 3 4 5 6 7 8

AlmondApricotAppleBananaCherryGrapeLemonLycheeLimeMangoOrangeOlivePaw Paw

6/2.506/2.756/3.006/3.756/4.75

30/2.5030/3.0030/3.2530/3.5054/3.0054/3.2554/3.5054/3.75

1/2.501/2.751/3.001/3.757/1.607/2.507/3.007/3.257/3.507/3.007/3.257/3.50

19/2.25

7.508.39.00

11.314.317.521.022.824.527.029.331.533.8

34.3641.5849.4877.31

120.4181.6261.5306.9356.0431.2506.0586.9672.0

29.035.141.865.2

105144207243282373438508583

119144171268402677973

1,1401,3201,4401,6901,9602,240

10.512.614.922.733.463.590.4

105122119137159178

0.9750.8050.6770.4330.2710.1960.1360.1160.1000.07580.06460.05570.0485

(Table 63)

Standard High Strength ConductorsQuinceRaisinSultanaWalnut

3/1.753/2.504/3.004/3.75

4/1.754/2.503/3.003/3.75

5.37.509.00

11.3

16.8434.3649.4877.31

8.7417.831.549.2

95195243380

12.724.428.343.9

3.251.590.8970.573

Aluminum Conductors, Aluminized Steel Reinforced (AS 3607/1989)ACSR/AZ

Notes : 1. The sectional area is the sum of the cross sectional areas of the relevant individual wires.2. For the basis of calculation of columns 5, 6, 7 and 8, see (AS 3607) Appendix A.

CodeWord

Al Galvanized St

Stranding and Wire Dia.(mm)

Approx.Overall Dia.

(mm)

SectionalArea

(mm2)

CalculatedEquiv. Al Area

(mm2)

Approx.Mass

(kg/km)

Min. CalculatedBreaking Load

(kN)

Calculated D.C.Resistance

( /km, 20 )

1 2 3 4 5 6 7 8

BarleyBeanCabbageCarrot

6/2.506/3.006/3.756/4.75

1/2.501/3.001/3.757/1.60

7.509.00

11.314.3

34.3649.4877.31

120.4

29.041.865.2

105

118170265399

10.214.521.432.0

0.9750.6770.4330.271

(Table 64)

52 Overhead Electrical Aluminum Conductors TAIHAN

Page 53: 0512 AL Conductor

Aluminum Conductors, Steel Reinforced ACSR

ASTM

ANSI

IEC

BS

AS

CSA

DIN

KSJI

SKE

PCO

TEC

ApplicationThis standard covers aluminum stranded conductors steel reinforcedwhich could withstand high tensile load to be used mainly for overheadtransmission lines, overhead distribution lines.

ConstructionThe center wire or wires are of galvanized steel and the outer layer orlayers of aluminum.

StandardsConforms to CSA C49.1

Conductor type means the ratio of steel to aluminum areas in percent.

CodeWord

Al

Al Al St TotalStSt

CoreCompleteConductor

AWGor

CMILS

St CompleteConductor

sq insq in sq in No. Dia. No. Dia. (pound)

( /1000ft,20 )

Nominal Area Stranding No. and Nominal Dia. of Wires

(in)

Nominal Dia.(in)

Nominal Weight(pound/1000ft)

RatedTensile

Strength

D.C.ResistanceCon-

ductorType

WrenTurkeySwanSparrowRobinRavenQuailPigeonPenguinOwlWaxwingPartridgePhoebeOstrichPiperMerlinLinnetOrioleChickadeeIbisLarkPelicanToucanHawkHenHeronSapsuckerDoveEagle-DuckGoldfinchGrosbeakEgret

17171717171717171713

616

61623

61623

61623

6101623231016231013101623

86421

1/03/03/04/0

266,800266,800266,800300,000300,000300,000336,400336,400336,400397,500397,500397,500477,000477,000477,000477,000500,000556,500556,500556,500605,000605,000636,000636,000636,000

0.01300.02060.03280.05210.06570.08290.10450.13180.16620.20950.20950.20950.23560.23560.23560.26420.26420.26420.31220.31220.31220.37460.37460.37460.37460.39270.43710.43710.43710.47520.47520.49950.49950.4995

0.00220.00340.00550.00870.01100.01380.01740.02200.02770.02720.01150.03410.01310.03830.05500.01470.04310.06170.01730.05080.07280.02080.03680.06110.08740.09160.04290.07120.10200.04660.06170.04900.08130.1140

0.01520.02400.03830.06080.07670.09670.12190.15380.19390.23670.221002436

0.24870.27390.29060.278903073

0.32590.32950.36300.38500.39540.41140.43570.46200.48430.48000.50830.53910.52180.53690.54850.58080.6133

0.05250.06610.08340.10520.11810.13270.14890.16720.18780.21090.12170.10130.12910.10740.10000.13670.11370.10590.14860.12360.11510.16280.14720.13540.12610.12910.15900.14630.13620.16580.10580.17000.15640.1456

0.05250.06610.08340.10520.11810.13270.14890.16720.18780.07030.12170.07880.12910.08350.10000.13670.08840.10590.14860.09610.11510.16280.08180.10530.12610.12910.08830.11380.13620.09210.10580.09440.12160.0874

0.05250.06610.08340.10520.11810.13270.14890.16720.18780.21090.12170.23640.12910.25050.30000.13670.26520.31770.14860.28830.34530.16280.24540.31590.37830.38730.26490.34140.40860.27630.31740.28320.36480.4370

0.1580.1980.2500.3160.3540.3980.4470.5020.5630.6330.6090.6420.6460.6800.7000.6840.7200.7410.7430.7830.8060.8140.8340.8580.8830.9040.9010.9270.9530.9400.9520.9630.9901.019

7451,1701,8302,7903,4804,2905,3506,5708,4209,5407,100

11,3007,980

12,60015,400

8,95014,00017,00010,40016,20020,00012,30015,40019,40023,40024,50017,80022,50027,20019,10022,50020,10025,00031,600

1.04520.65770.41340.26010.20620.16340.12970.10280.08160.06470.06490.06510.05770.05790.05790.05150.05160.05170.04360.04370.04370.03630.03640.03640.03640.03480.03120.03120.03120.02870.02870.02730.02730.0273

15.4 24.539.062.078.198.6

124.3156.7197.6249250251281282282315316316373373374447448448448470522523523568569597597598

7.311.618.429.337.046.658.874.193.49239

11644

13018650

1462095817224770

125207296310145241345158209166275387

22.736.157.491.3115.1145.2183.1230.8291.0

341289367325412468365462525431545621517573655744780667764868726778763872985

6666666666

182618263018263018263018222630302226302254222630

111111111717177177177177777777777

19

(Table 65)

Galvanized steel

Aluminum conductor

53TAIHAN Overhead Electrical Aluminum Conductors

Page 54: 0512 AL Conductor

Aluminum Conductors, Steel Reinforced ACSR

Conductor type means the ratio of steel to aluminum areas in percent.

CodeWord

Al

Al Al St TotalStSt

CoreCompleteConductor

AWGor

CMILS

St CompleteConductor

sq insq in sq in No. Dia. No. Dia. (pound)

( /1000ft,20 )

Nominal Area Stranding No. and Nominal Dia. of Wires

(in)

Nominal Dia.(in)

Nominal Weight(pound/1000ft)

RatedTensile

Strength

D.C.Resistance

Con-ductorType

GooseGull-StarlingRedwing-CrowDrakeMallardMacawCondor-Crane-CanaryPhoenixCardinalSnowbirdCurlewBeaumontFinch-GrackleScissortailPheasant-Martin-Plover-Parrot-Falcon-

135

13162313131623

513

513

513

513

513

513

513

513

513

513

513

913

4

636,000666,600666,600715,500715,500715,500715,500795,000795,000795,000795,000874,500874,500900,000900,000954,000954,000

1,033,5001,033,5001,113,0001,113,0001,192,5001,192,5001,272,0001,272,0001,351,5001,351,5001,431,0001,431,0001,510,5001,510,5001,590,0001,590,0001,590,000

0.49950.52350.52350.56200.56200.56200.56200.62440.62440.62440.62440.68680.68680.70690.70690.74930.74930.81170.81170.87410.87410.93660.93660.99900.99901.06151.06151.12391.12391.18631.18631.24881.24881.2488

0.06470.02690.06790.09150.12800.02890.07280.10170.14240.03210.08090.03540.08910.03630.09160.03850.09710.04180.10520.04490.11090.04820.11870.05140.12660.05460.13440.05790.14240.06100.15010.11020.15830.0540

0.56420.55040.59140.65350.69000.59090.63480.72610.76680.65650.70530.72220.77590.74320.79850.78780.84640.85350.91690.91900.98500.94841.05531.05041.12561.11611.19591.18181.26631.24731.33641.35901.40711.3028

0.10850.12600.11110.16590.15440.13050.11510.17490.16280.13760.12130.14430.12730.14640.12910.15070.13290.15690.13830.16280.14360.16850.14860.17400.15350.17940.15820.18460.16280.18960.16720.18200.17160.1486

0.10850.07000.11110.12900.09260.07250.11510.13600.09770.07640.12130.08020.12730.08130.12910.08370.13290.08720.13830.09040.08620.09360.08920.09670.09210.09970.09490.10260.09770.10530.10030.14160.10300.0991

0.32550.21000.33330.38700.46300.21750.34530.40800.48850.22920.36390.24060.38190.24390.38730.25110.39870.26160.41490.27120.43100.28080.44600.2901046050.29910.47450.30780.48850.31590.50150.42480.51500.2973

0.9770.9661.0001.0511.0811.0011.0361.1081.1401.0551.0921.1061.1461.1221.1621.1551.1961.2031.2451.2481.2931.2921.3381.3341.3821.3761.4241.4151.4651.4541.5051.5171.5451.486

23,70017,70024,50028,10034,60019,00026,30031,30038,50021,10028,50022,80031,40023,50032,30024,50034,30026,60037,10028,40040,30030,40043,10032,50044,90034,50047,60036,50050,50038,50053,20047,60056,10039,500

0.02730.02610.02610.02430.02430.02430.02430.02180.02190.02190.02190.01990.01990.01930.01930.01820.01820.01680.01680.01560.01560.01460.01460.01370.01370.01290.01290.01210.01220.01150.01150.01090.01090.0109

599627627672673673673747747747748822823846847897898972973

1,0461,0481,1211,1221,1961,1971,2711,2721,3451,3471,4201,4221,4951,4961,496

21991

23031043498

247344484109274120302123310130329141356152376163403174430185456196484206511372537183

818718857982

1,107771920

1,0911,231

8561,022

9421,125

9691,1571,0271,2271,1131,3281,1981,4241,2841,5251,3701,6271,4561,7281,5411,8311,6261,9331,8672,0331,679

54425426304242263042544254425442544254425442544254425442544254485472

7777

19777

1977777777777

197

197

197

197

197

197

197

(Table 65)

54 Overhead Electrical Aluminum Conductors TAIHAN

Page 55: 0512 AL Conductor

Compact Aluminum Conductors Steel Reinforced (CSA C49.2)

ASTM

ANSI

IEC

BS

AS

CSA

DIN

KSJI

SKE

PCO

TEC

Conductor type means the ratio of steel to aluminum areas in percent.

CodeWord

Con-ductorType

AWGor

CMILSsq in

St

(sq in)

CompleteConductor

(sq in)

AlNominal Area Nominal Dia.

(in)

Nominal Weight

(pound/1000ft)

RatedTensile

Strength

(pound)

D.C.Resistance

( /1000ft,20 )

No. of Al

Wires St Wire Al St TotalConductor

CodMinnowSardineBassMulletHerringPikePollockFlounderCarpHaddockPickerelShadLampreySoleSculpinHakeCuskScup--

1734531734531734531734531734173417171766

88866644422211

1/01/02/03/04/0

266,800336,400

0.01300.01300.01300.02060.02060.02060.03280.03280.03280.05210.05210.05210.06570.06570.08290.08290.10450.13180.16620.20950.2642

0.00220.00430.00690.00340.00690.01100.00550.01100.01740.00870.01740.02770.01100.02200.01380.02770.01740.02200.02770.01150.0147

0.01520.01730.01990.02400.02750.03160.03830.04380.05020.06080.06950.07980.07670.08770.09670.11060.12190.15380.19390.22100.2789

6666666666666666666

1818

0.05250.07430.09370.06610.09370.11820.08340.11820.14900.10520.14900.18780.11820.16720.13270.18780.14900.16720.18780.12170.1367

0.1450.1540.1650.1820.1930.2080.2290.2430.2640.2900.3080.3310.3260.3460.3650.3880.4100.4610.5170.5590.628

7451,1101,5101,1701,7202,4001,8302,7103,6902,7904,1505,7903,4805,1904,2906,5105,3506,6708,4207,1008,950

1.04521.04521.04520.65770.65770.65770.41340.41340.41340.26010.26010.26010.20620.20620.16340.16340.12970.10280.08160.06470.0515

15.415.415.424.524.524.539.039.039.062.062.062.078.178.198.698.6

124.3156.7197.6

250315

7.314.623.311.623.337.018.437.058.829.358.893.437.074.146.693.458.874.193.4

3950

22.730.038.736.147.861.557.476.097.891.3

120.8155.4115.1152.2145.2192.0183.1230.8291.0

289365

(Table 66)

55TAIHAN Overhead Electrical Aluminum Conductors

Page 56: 0512 AL Conductor

Stranded All-aluminum ConductorAAC

ApplicationThis standard covers stranded hard-drawn circular aluminumconductors to be used mainly for overhead distribution wire, overheadfeeder.

ConstructionStranded hard-drawn aluminum conductors

StandardsConforms to DIN 48201

Area

(mm2)

EquivalentArea (HDCC)

Strandingand

Wires Dia.

OverallDia.

Weight NominalBreaking

Load

Max. D.C.Resistance

Rating

(amps)

Nominal Actual (mm2) (mm) (mm) (kg/km) (kp) ( /km, 20 ) Temperate Tropical16253550507095

120150185240300400500625800

1,000

15.8924.2534.3649.4848.3665.8293.27

117.00147.10181.60242.5299.4400.1499.8626.2802.4999.7

101521313041607090

110150155245305385490615

7/1.77/2.17/2.57/3.0

19/1.819/2.1019/2.5019/2.8037/2.2537/2.5061/2.2561/2.5061/2.8961/3.2391/2.9691/3.3591/3.74

5.16.37.59.09.0

10.512.514.015.717.520.222.526.029.132.836.841.1

446794

135133181256322408501670827

1,1051,3811,7332,2192,766

290425585810860

1,1501,5951,9102,5703,1054,0154,8506,1907,6009,690

12,05514,845

1.80171.18060.83320.57860.59480.43700.30840.24590.19600.15880.11920.096510.072220.057820.046250.036110.02897

87112138172172206254291333379448509602689785904

1,027

597489

107107124146160176191207217222211176

52-

(Table 67)

56 Overhead Electrical Aluminum Conductors TAIHAN

Page 57: 0512 AL Conductor

Aluminum Conductors, Steel ReinforcedACSR

ASTM

ANSI

IEC

BS

AS

CSA

DIN

KSJI

SKE

PCO

TEC

ApplicationThis standard covers aluminum stranded conductors steel reinforcedwhich could withstand high tensile load to be used mainly for overheadtransmission lines, overhead distribution lines.

ConstructionThe center wire or wires are of steel and the outer layer or layers ofaluminum.

StandardsConforms to DIN 48204

Area (mm2)

Equiv.Area

(HDCC)

Stranding and Wires Dia.

(mm)

OverallDia.

Weight

(kg/km)

NominalBreaking

Load

Max. D.C.Resistance

Rating

(amps)NominalAl St Total

St (mm2)Al Al Al St Total Temperate Tropical(kp)( /km,20 )St (mm)

162535445050709595

105120120125150170185210210230240265300305340380385435450490550560680

2.54.06.0

32.08.0

301215557520703025403035503040355040305035554065705085

15.323.834.344.048.351.269.994.496.5

105.7121.6122.0127.9148.9171.8183.8209.1212.1230.9243.0263.7304.3304.6339.3382.0386.0434.3448.7490.3550.0561.7678.8

2.64.05.7

31.78.0

29.811.415.356.375.519.871.329.824.240.129.834.149.529.839.534.149.539.529.849.534.156.339.563.671.349.586.0

17.927.840.075.756.381.081.3

109.7152.8181.5141.4193.3157.7173.1211.9213.6243.2261.6260.7282.5297.8353.7344.1369.1431.5420.1490.6488.2553.9621.3611.2764.8

9.617.521.627.730.432.244.059.460.866.576.576.780.493.6

108.0116132133145153166191192213240243273282308346353427

6/1.806/2.256/2.70

14/2.006/3.20

12/2.3326/1.8526/2.1512/3.2014/3.1026/2.4412/3.6030/2.3326/2.7030/2.7026/3.0026/3.2030/3.0024/3.5026/3.4524/3.7426/3.8654/2.6848/3.0054/3.0048/3.2054/3.2048/3.4554/3.4054/3.6048/3.8654/4.00

1/1.801/2.251/2.707/2.401/3.207/2.337/1.447/1.677/3.20

19/2.257/1.907/3.607/2.337/2.107/2.707/2.337/2.497/3.007/2.337/2.687/2.497/3.007/2.687/2.337/3.007/2.497/3.207/2.687/3.407/3.607/3.00

19/2.40

5.46.88.1

11.29.6

11.711.713.616.017.515.518.016.117.118.919.020.321.021.021.922.424.524.125.027.026.728.828.730.632.432.236.0

426594

122132141193260266292336337353411475507577587638671728840843938

1,0561,0671,2031,2411,3561,5201,5531,868

203246

25064

23791

123446599158564238194319239273394239316274396317242397277450320510572401702

6297

140372196378284383712891494901591605794746850981877987

1,0021,2361,1601,1801,4581,3441,6531,5611,8662,0921,9542,570

595920

1,2654,5001,7104,3802,6803,5757,935

10,8454,565

10,0005,7605,5257,6756,6207,4909,3907,3108,6408,305

10,7009,9409,290

12,31010,48013,64512,07515,31017,06014,89521,040

85114140170172187217260271289304359309341373386418423442457477521520553594597641650687734742830

587489

10010510912714514214516115416117317918519319019919920420520821320721120020518916817380

1.87931.20280.83530.65730.59460.56440.41300.30580.29920.27360.2374023640.22590.19390.16820.15710.13800.13630.12490.11880.10940.09490.09490.08510.07570.07480.06660.06440.05900.05260.051400.0426

(Table 68)

Galvanized steel

Aluminum conductor

57TAIHAN Overhead Electrical Aluminum Conductors

Page 58: 0512 AL Conductor

ReelDesignation

(D) (d) (W1) (W2) (h) (t) (in) (No.) (ft3) (lb)

Flange Dia.

Drum Dia.

OverallWidth

InsideTraverse

ArborHole Dia.

Thickness ofCircumference

Battens

No. of Bolt

Measurement Approx.Weight

Dia. of Bolt

3-13-23-33-43-54-14-24-34-44-54-64-75-15-25-35-45-55-66-16-26-36-46-56-67-17-27-37-47-58-18-28-38-48-58-69-19-29-39-49-59-69-79-8

20.521.722.824.025.224.025.226.427.628.729.931.126.427.628.729.931.132.332.333.534.635.837.038.235.837.038.239.441.337.038.239.441.343.345.343.345.347.245.347.249.251.253.2

11.811.811.811.811.813.813.813.813.813.813.813.815.715.715.715.715.715.717.717.717.717.717.717.719.719.719.719.719.723.623.623.623.623.623.623.623.623.627.627.627.627.627.6

15.715.715.715.715.715.715.715.715.715.715.715.719.719.719.719.719.719.719.719.719.719.719.719.723.623.623.623.623.623.623.623.623.623.623.629.529.529.529.529.529.529.529.5

12.912.912.912.912.912.912.912.912.912.912.912.915.915.915.715.715.715.715.715.715.715.715.715.719.719.719.719.719.719.719.719.719.719.719.724.824.824.824.824.824.824.824.8

2.02.02.02.02.02.02.02.02.02.02.02.03.03.03.03.03.03.03.03.03.03.03.03.03.03.03.03.03.03.03.03.03.03.03.04.34.34.34.34.34.34.34.3

1.21.21.21.21.21.21.21.21.21.21.21.21.21.21.21.21.21.21.21.21.21.21.21.21.41.41.41.41.41.41.41.41.41.41.41.41.41.41.41.41.41.41.4

0.50.50.50.50.50.50.50.50.50.50.50.50.60.60.60.60.60.60.60.60.60.60.60.60.60.60.60.60.60.60.60.60.60.60.60.60.60.60.60.60.60.60.6

4444444444444444444444444444444444444444444

5.15.66.26.87.46.87.48.18.79.4

10.310.910.010.811.712.613.514.514.515.516.617.618.719.921.422.724.225.528.022.724.225.528.030.533.137.741.144.441.144.448.351.755.6

64.066.070.575.079.481.683.888.290.494.8

101.4105.8119.0125.7132.3136.7143.3149.9152.1160.9167.5176.4183.0191.8211.6218.3227.1235.9251.3222.7231.5240.3253.5271.2286.6339.5361.6381.4374.8394.6416.7436.5467.4

(Approx. in inch)Standard Dimensions of Reel for Aluminum Conductor

Packing and Marking

The packing of the conductor is an intergral part of the manufacturing process, and the kind of package must be predetermined beforeproduction can begin.Unless otherwise specified or agreed with in case of order, ACSR shall be shipped on Taihan standard wooden reels having dimensions andweights as given in the table shown below.Taihan standard wooden reels shall have enough condition to stand against the ordinary handling in transportation and shipping and be foundready and handy enough at the time of installation in site. Especially, in case that users require the metal reel, we can serve our standard metalreels which have the same capacity as that of the wooden reel or special designed metal reels.The reels will be stenciled legibly with following information; serial number, size and kind of conductor, length of conductor, and any otherindentification marks specified on the order by the purchaser.

58 Overhead Electrical Aluminum Conductors TAIHAN

Page 59: 0512 AL Conductor

ReelDesignation

(D) (d) (W1) (W2) (h) (t) (in) (No.) (ft3) (lb)

Flange Dia.

Drum Dia.

OverallWidth

InsideTraverse

ArborHole Dia.

Thickness ofCircumference

Battens

No. of Bolt

Measurement Approx.Weight

Dia. of Bolt

10-110-210-310-410-510-611-111-211-311-411-512-112-212-312-412-513-113-213-313-413-513-613-714-114-214-314-414-514-614-715-115-215-315-416-116-216-316-417-117-217-317-417-517-618-118-218-318-4

49.251.253.255.157.159.155.157.159.161.063.155.157.159.161.063.059.161.063.065.066.968.970.966.968.970.972.874.876.878.774.876.878.782.778.382.786.690.682.786.690.694.598.4

102.490.694.598.4

102.4

31.531.531.531.531.531.531.531.531.531.531.535.435.435.435.435.439.439.439.439.439.439.439.447.247.247.247.247.247.247.255.155.155.1551

55.155.155.155.162.862.862.962.962.962.970.970.970.970.9

29.529.529.529.529.529.535.435.435.435.435.435.435.435.435.435.435.435.435.435.435.435.435.441.341.341.341.341.341.341.341.341.341.341.347.247.247.247.247.247.247.247.247.247.247.247.247.247.2

24.824.824.824.824.824.829.529.529.529.529.529.529.529.529.529.529.529.529.529.529.529.529.534.334.334.334.334.334.334.334.334.334.334.340.240.240.240.240.240.240.240.240.240.240.240.240.240.2

4.34.34.34.34.34.34.34.34.34.34.34.34.34.34.34.34.34.34.34.34.34.34.34.34.34.34.34.34.34.34.34.34.34.34.34.34.34.34.34.34.34.34.34.34.34.34.34.3

1.41.41.41.41.41.41.41.41.41.41.41.41.41.41.41.41.81.81.81.81.81.81.81.81.81.81.81.81.81.81.81.81.81.81.81.81.81.81.81.81.81.81.81.81.81.81.81.8

0.60.60.60.60.60.60.60.60.60.60.60.60.60.60.60.60.60.60.60.60.60.60.60.70.70.70.70.70.70.70.70.70.70.70.70.70.70.70.70.70.70.70.70.70.70.70.70.7

444444555555555555555556666666666688888888888888

48.2 51.855.659.663.668.171.175.881.086.194.671.175.881.086.192.083.188.493.899.5105111117123130137144152160168152160168184191209228250209229249271293316249271293316

445.3465.2487.2509.3533.5557.8615.5650.4681.2709.9743.0643.7672.4701.1731.9765.0784.8820.1851.0888.5921.5956.8994.3

1,170.61,210.31,258.81,322.81,342.61,391.11,435.21,404.31,459.41,503.51,627.01,607.21,706.41,805.61,913.61,882.71,935.61,995.22,105.42,220.02,341.32,079.02,191.42,306.02,427.3

(Approx. in inch)Standard Dimensions of Reel for Aluminum Conductor

Dimensions of Wooden Reels

���������������

������������

yyyyyyyyyyyy

�����

���

yyy�

��

yyy���

Barrel lagging

W1W1W2W2

tt

Ddh

Center supportBarrel Bolts & Washer

Reinforcement

Circumference Battens

59TAIHAN Overhead Electrical Aluminum Conductors

Page 60: 0512 AL Conductor

ItemAluminum Copper

Hard-drawn Al-alloy Hard-drawnAnnealedStandard

Melting Point, Electrical Resistivity at 20 , in

cmConductivity at 20 , % IACSTemperature Coefficient of Resistanace at 20 , per Density at 20 , g/cub, cm

lb/cub, inCoefficient of Linear Expansion per Weight Ratio, Same VolumeResistance Ratio, Same Size

Resistance Ratio, Same Length and Same WeightTensile Strength RatioFor Same Length and Resistance, Cross Sectional Area

DiameterWeightBreaking Strength

6581.112772.8264

610.00402.700.09765

23 10-6

30.371163.93159.01

48.29Approx. 40159.01126.12

48.295Approx. 60

Approx. 6501.305363.3156

520.00362.700.09765

23 10-6

30.371192.30186.54

56.65Approx. 73185.54136.58

56.653Approx. 135

1.0830.699781.7774

970.003818.890.321

17 10-6

100103.09100100100100100100100

1.0830.678791.7241

1000.003938.890.321

17 10-6

100100

Comparison of Aluminum and Copper

Conversion Factors

1in= 25.4mm, 1cmil = 5.067 10-4mm2, 1mil = 2.54 10-2mm, 1 lb/1000ft = 1.488kg/km,1ft = 3.048 10-1m, 1 lb =4.536 10-1kg, 1in3 = 1.639 10-5m3

The metric unit of force in SI(System International) units is the newton. (N), which is defined as that force which, when applied to a body havinga mass of 1kg, gives it an acceleration of 1m/s2.

The derived SI unit for pressure or stress is the newton per square meter(N/m2), which has been named the pascal(Pa) by the GeneralConference of Weights and Measures. Since 1ksi=6894757Pa the metric equivalents are expressed as megapascal(MPa), which is the same asMn/m2 and N/mm2.

1ksi = 103psi 1kgf/mm2 = 1.42ksi1psi = 6.9KPa 1ksi = 0.704kgf/mm2

1ksi = 6.9MPa kgf = 9.80665 newtons(N)

60 Overhead Electrical Aluminum Conductors TAIHAN

Page 61: 0512 AL Conductor

Code Word Table No. Page No.AAcorn 38

Akron 34

Alliance 34

Almond 38, 41, 63

Alton 34

Ames 34

Amherst 34

Anaheim 34

Anemone 28

Anona 37, 40

Ant 60

Antelope 61

Aphis 60

Appaloosa 53

Appaloosa/XLPE 55

Apple 37, 39, 63

Apple/XLPE 42

Apricot 37, 40, 63

Apricot/XLPE 43

Arbutus 28

Ash 37

Aspen 38

Aster 28

Azusa 34

BBanana 63

Barley 64

Bass 66

Basswood 37

Batang 61

Bean 64

Bear 61

Beaumont 65

Beavor 61

Bee 60

Beech 38, 41

Beetle 60

Bison 61

Bittern 29

Bitterroot 28

Bluebell 28

Bluebird 29

Bluebonnet 28

Bluebottle 60

Bluejay 29

Bobolink 29

Brahma 35, 36

Brant 29

Breadfruit 37, 41

Buckeye 38, 41

Bull 45

Bull/XLPE 47

Bunting 29

36

33

33

36, 37, 52

33

33

33

33

25

35, 37

48

49

48

40

40

35, 37, 52

37

35, 37, 52

37

25

35

36

24

33

52

52

55

35

49

52

49

54

49

48

36, 37

48

49

27

25

25

27

25

48

27

27

34

26

35, 37

36, 37

38

38

27

Alphabetical List

Code Word Table No. Page No.Butte 34

Butterfly 60

Butternut 38, 41

CCabbage 64

Cairo 34

Camel 61

Camellia 28

Canary 29, 65

Canna 28

Canton 34

Caracal 61

Cardinal 29, 65

Carnation 28

Carp 66

Carrot 64

Cat 61

Catalpa 37

Catbird 29

Caterpillar 60

Cattail 28

Cenia 49

Cenia 51

Centipede 60

Chafer 60

Cherry 37, 39, 63

Cherry/XLPE 42

Chestnut 38, 41

Chickadee 29, 65

Chinquapin 37

Chokeberry 38

Chola 53

Chola/XLPE 55

Chow 45

Chow/XLPE 47

Chukar 29

Cicada 60

Clam 48

Clam/XLPE 50

Clegg 60

Clydesdale 52

Clydesdale/XLPE 54

Cochin 35, 36

Cockroach 60

Cockscomb 28

Cod 66

Collie 44

Collie/XLPE 46

Columbine 28

Conch 49

Conch/XLPE 51

Condor 29, 65

Coot 29

Coreopsis 28

33

48

36, 37

52

33

49

25

27, 54

24

33

49

27, 54

25

55

52

49

35

27

48

25

39

39

48

48

35, 37, 52

37

36, 37

26, 53

35

36

40

40

38

38

27

48

39

39

48

40

40

34

48

25

55

38

38

25

39

39

27, 54

27

25

Code Word Table No. Page No.Cosmos 28

Costena 53

Costena/XLPE 55

Cottonwood 38

Cougar 61

Cowslip 28

Coyote 61

Crabapple 37, 40

Crane 29, 65

Cricket 60

Criollo 52

Criollo/XLPE 54

Crocus 28

Crow 29, 65

Cuckoo 29

Cumquat 37

Curlew 29, 65

Cusk 66

DDachshund 44

Dachshund/XLPE 46

Daffodil 28

Dahlia 28

Daisy 28

Darien 34

Dear 61

Dingo 61

Dipper 29

Doberman 44

Doberman/XLPE 46

Dog 61

Dogwood 28

Dorking 35, 36

Dotterel 35, 36

Dove 29, 65

Drake 29, 65

Drone 60

Duck 65

EEagle 29, 65

Earwig 60

Egret 29, 65

Elk 61

Elgin 34

Eskimo 45

Eskimo/XLPE 47

FFalcon 29, 65

Ferret 61

Fig 37, 40

Fig/XLPE 43

Filbert 38, 41

Finch 29, 65

Flag 28

24

40

40

36

49

25

49

35, 37

27, 54

48

40

40

25

27, 54

27

35

27, 54

55

38

38

24

24

24

33

49

49

27

38

38

49

25

34

34

26, 53

27, 54

48

53

26, 53

48

27, 53

49

33

38

38

27, 54

49

35, 37

37

36, 37

27, 54

24

61TAIHAN Overhead Electrical Aluminum Conductors

Page 62: 0512 AL Conductor

Code Word Table No. Page No.Flamingo 29

Flicker 29

Flint 34

Flounder 66

Fly 60

Fox 61

Fusus 48

Fusus/XLPE 50

GGannet 29

Ginkgo 37

Gladiolus 28

Gnat 60

Goat 61

Goldenrod 28

Goldentuft 28

Goldfinch 65

Goose 65

Gopher 61

Grackle 29, 65

Grape 63

Grapefruit 37, 40

Grasshopper 60

Greely 34

Grosbeak 29, 65

Grouse 35, 36

Grullo 53

Grullo/XLPE 55

Guinea 35, 36

Gull 65

Gumwood 38

HHackberry 38, 41

Hackney 53

Hackney/XLPE 55

Haddock 66

Haiotis 48

Haiotis/XLPE 50

Hake 66

Hanoverian 52

Hanoverian/XLPE 54

Hare 61

Haw 37

Hawk 29, 65

Hawkweed 28

Hawthorn 28

Hazelnut 38

Hen 29, 65

Heron 65

Herring 66

Heuchera 28

Hickory 38, 41

Hornet 60

Horse 61

27

26

33

55

48

49

39

39

27

35

25

48

49

25

24

53

54

49

27, 54

52

35, 37

48

33

27, 53

34

40

40

34

54

36

36, 37

40

40

55

39

39

55

40

40

49

35

26, 53

25

25

36

26, 53

53

55

24

36, 37

48

49

Code Word Table No. Page No.Huckleberry 37, 40

Hyacinth 28

Hyena 61

IIbis 29, 65

Iris 28

Ironwood 37

JJaguar 61

Jessamine 28

Joree 29

KKingbird 29

Kiwi 29

LLamprey 66

Ladybird 60

Lapwing 29

Lark 29, 65

Larkspur 28

Laurel 28

Leghorn 35, 36

Lemon 37, 63

Leo 62

Leonids 62

Leopard 61

Libra 62

Lilac 28

Lily 28

Lime 63

Linnet 29, 65

Lion 61

Locust 60

Lupine 28

Lychee 63

Lynx 61

MMacaw 65

Magnolia 28

Malemute 44

Malemute/XLPE 46

Mallard 29, 65

Mango 37, 63

Marigold 28

Mars 62

Martin 29, 65

Maybug 60

Meadowsweet 28

Melita 48

Melita/XLPE 50

Mercury 62

Merlin 29, 65

Midge 60

Mink 61

35, 37

24

49

26, 53

24

35

49

25

27

27

27

55

48

27

26, 53

25

24

34

35, 52

51

51

49

51

25

24

52

26, 53

49

48

25

52

49

54

25

38

38

27, 54

35, 52

25

51

27, 54

48

24

39

39

51

26, 53

48

49

Code Word Table No. Page No.Minnow 66

Minorca 35, 36

Mistletoe 28

Mockernut 38

Mole 61

Molles 37, 40

Moon 62

Moose 61

Morgan 53

Morgan/XLPE 55

Morochuca 53

Morochuca/XLPE 55

Mosquito 60

Moth 60

Mulberry 37, 40

Mullet 66

Murex 48

Murex/XLPE 50

Mursia 49

Mursia/XLPE 51

Mustang 52

Mustang/XLPE 54

NNarcissus 28

Nassa 48

Nassa/XLPE 50

Nasturtium 28

Nectarine 37, 39

Nectarine/XLPE 43

Neptune 62

Neritina 49

Neritina/XLPE 51

Nuthatch 29

OOldenburg 52

Oldenburg/XLPE 54

Olive 37, 40, 63

Olive/XLPE 43

Orange 37, 40, 63

Orange/XLPE 43

Orchid 28

Oriole 29, 65

Orion 62

Ortolan 29

Osprey 29

Ostrich 29, 65

Otter 61

Owl 65

Oxlip 28

Oyster 48

Oyster/XLPE 50

PPalmino 53

Palmino/XLPE 55

55

34

24

36

49

35, 37

51

49

40

40

40

40

48

48

35, 37

55

39

39

39

39

40

40

25

39

39

25

35, 37

37

51

39

39

27

40

40

35, 37, 52

37

35, 37, 52

37

24

26, 53

51

27

26

26, 53

49

53

24

39

39

40

40

62 Overhead Electrical Aluminum Conductors TAIHAN

Page 63: 0512 AL Conductor

Code Word Table No. Page No.Paludina 49

Paludina/XLPE 51

Pansy 28

Panther 61

Parakeet 29

Parrot 29, 65

Partridge 29, 65

Paw Paw 37, 40, 63

Peach 37, 40

Peach/XLPE 43

Peachbell 28

Peacock 29

Pear 37, 39

Pear/XLPE 42

Pecan 38, 41

Pekingese 44

Pekingese/XLPE 46

Pelican 29, 65

Penguin 29, 65

Peony 28

Percheron 52

Percheron/XLPE 54

Periwinkle 49

Periwinkle/XLPE 51

Persimmon 37, 40

Petrel 35, 36

Petunia 28

Pheasant 29, 65

Phlox 28

Phoebe 65

Phoenix 65

Pickerel 66

Pigeon 29, 65

Pignut 38, 41

Pike 66

Pinto 52

Pinto/XLPE 54

Piper 65

Plover 29, 65

Plum 37, 40

Plum/XLPE 43

Pluto 62

Pollock 66

Pomegranate 37, 40

Pomegranate/XLPE 43

Poppy 28

Portunus 48

Portunus/XLPE 50

Purpura 48

Purpura/XLPE 50

QQuail 29, 65

Quince 37, 40, 63

Quince/XLPE 43

39

39

24

49

26

27, 54

26, 53

35, 37, 52

35, 37

37

24

26

35, 37

37

36, 37

38

38

26, 53

26, 53

24

40

40

39

39

35, 37

34

25

27, 54

24

53

54

55

26, 53

36, 37

55

40

40

53

27, 54

36, 37

37

51

55

35, 37

37

24

39

39

39

39

26, 53

35, 37, 52

37

Code Word Table No. Page No.RRabbit 61

Raccoon 61

Rail 29

Raisin 63

Raven 29, 65

Redbud 38

Redwing 29, 65

Robin 29, 65

Rook 29

Rose 28

Ruddy 29

Runcina 49

Runcina/XLPE 51

SSagebrush 28

Sapsucker 65

Sardine 66

Sassafras 37

Saturn 62

Scissrotail 65

Scorpion 60

Scoter 29

Sculpin 66

Scup 66

Setter 45

Setter/XLPE 47

Shad 66

Sheep 61

Shepherd 45

Shepherd/XLPE 47

Silverbelt 37

Sirius 62

Skunk 61

Snapdragon 28

Sneezewort 28

Snowbird 65

Sole 66

Spaniel 44

Spaniel/XLPE 46

Sparate 29

Sparrow 29, 65

Spider 60

Squab 29

Squirrel 61

Starling 29, 65

Stilt 29

Suffolk 53

Suffolk/XLPE 55

Sultana 63

Sumac 37

Swallow 29

Swan 29, 65

Swanate 29

49

49

27

52

26, 53

36

27, 54

26, 53

27

24

27

39

39

25

53

55

35

51

54

48

27

55

55

38

38

55

49

38

38

35

51

49

25

24

54

55

38

38

26

26, 53

48

26

49

27, 54

27

40

40

52

35

26

26, 53

26

Code Word Table No. Page No.Swift 29

Sycamore 37

Syringa 28

TTanager 29

Tangerine 37

Tarantula 60

Taurus 62

Teal 29

Tern 29

Terrier 45

Terrier/XLPE 47

Thrasher 29

Thrush 29

Tiger 61

Toucan 65

Trillium 28

Triton 49, 62

Triton/XLPE 51

Trophon 48

Trophon/XLPE 50

Tulip 28

Tupelo 37

Turkey 29, 65

UUranus 62

Ursula 62

VValerian 28

Venus 62

Verbena 28

Violet 28

Voluta 49

Voluta/XLPE 51

WWalnut 38, 41, 63

Wasp 60

Waxwing 29, 65

Weasel 61

Weevil 60

Whelk 49

Whelk/XLPE 51

Wolf 61

Wood Duck 29

Wren 65

ZZebra 61

Zinnia 28

Zuzara 49

Zuzara/XLPE 51

27

35

24

27

35

48

51

26

27

38

38

27

26

49

53

25

39, 51

39

39

39

24

35

26, 53

51

51

24

51

24

24

39

39

36, 37, 52

48

26, 53

49

48

39

39

49

26

53

49

24

39

39

63TAIHAN Overhead Electrical Aluminum Conductors

Page 64: 0512 AL Conductor

Head Office

Overseas Sales Team

Domestic Sales Team

Insong Building, 194-15, 1-ga, Hoehyeon-dong, Jung-gu, Seoul, Korea

Tel. 82-2-316-9114 Fax. 82-2-316-9429

Tel. 82-2-316-9433 Fax. 82-2-316-9429

Tel. 82-2-316-9261~4 Fax. 82-2-316-9429

www.taihan.com

R & D Center996, Siheung-dong,Geumcheon-gu, Seoul,Korea

Tel. 82-2-890-9114Fax. 82-2-806-0186

Anyang Plant785, Gwanyang-dong, Dongan-gu, Anyang,Gyeonggi-do, Korea

Tel. 82-31-420-9114Fax. 82-31-423-2685

Sihung Plant113-119, Sihung-dong, Geumchon-gu, Seoul,Korea

Tel. 82-2-890-9114Fax. 82-2-808-6320

Ansan Plant603, Seonggok-dong,Danwon-gu, Ansan,Gyeonggi-do, Korea

Tel. 82-31-490-5114Fax. 82-31-491-3721

R & D CENTER AND PLANTS

Singapore Office

629 Aljunied Road #05-19, Cititech IndustrialBuilding, Singapore389838, Singapore

Tel. 65-6842-5069Fax. 65-6842-5076

Kuala Lumpur Office

15th Floor, KenangaInternational, JL. Sultanlsmail, 50250 KualaLumpur, Malaysia

Tel. 60-3-2161-8017Fax. 60-3-2161-3628

Riyadh Office

Al Akariyah Shopping Center 2, Room No.726,Olaya Road, P.O.Box 201,Riyadh, Saudi Arabia

Tel. 966-1-419-0227Fax. 966-1-419-0262

Shanghai Office

A410 Far East InternationalPlaza 319 Xian Xia RoadChangning District,Shanghai, China

Tel. 86-21-6235-1263Fax. 86-21-6235-1267

Philippines Office

10A Queen’s Street DonaRita Village TalambanCebu City 6000

Tel. 63-32-346-8799Fax. 63-32-344-8581

Dubai Office

Flat no. 705, Al SafaTower, Sheikh ZayedRoad, Dubai, U.A.EP.O.Box 117561

Tel. 97-14-331-7233Fax. 97-14-331-7322

Thailand Office

253, 26th Floor Asoke,Sukhumvit 21 Road,Klongtoeynua, Wattana,Bangkok 10110, Thailand

Tel. 66-2-664-1464Fax. 66-2-664-4002

Malesela Taihan Electric Cable (Pty) Ltd.Vereeniging 1930, Steel Road,Peacehaven Vereeniging 1939,Gauteng, South Africa

Tel. 27-16-450-8200 Fax. 27-16-423-3406http://www.m-tec.co.za

Skytel Co., LtdSkytel Plaza BuildingChinggisKhan Ave-9,Ulaanbaatar 210603, Mongolia

Tel. 976-1-318488Fax. 976-1-318487http://www.skytel.com

OVERSEAS OFFICES

OVERSEAS SUBSIDIARIES

Specifications are subject to improvement or change without notice. Please contact your local agent or TAIHAN to confirm the latest product information. TPE-0501-0506