Page 1: 04/111. 2 Benefits of Using a Power Analyzer: Easily Identify Power Quality Issues Generate Detailed Reports Outlining Power Problems Utilize Smart Power

04/11 1

Page 2: 04/111. 2 Benefits of Using a Power Analyzer: Easily Identify Power Quality Issues Generate Detailed Reports Outlining Power Problems Utilize Smart Power

04/11 2

Page 3: 04/111. 2 Benefits of Using a Power Analyzer: Easily Identify Power Quality Issues Generate Detailed Reports Outlining Power Problems Utilize Smart Power

Benefits of Using a Power Analyzer:

• Easily Identify Power Quality Issues

• Generate Detailed Reports Outlining Power Problems

• Utilize Smart Power Experience to Solve Complex Power Quality Problems

• Eliminate Unnecessary Service Calls and Returned Equipment

04/11 3

Page 4: 04/111. 2 Benefits of Using a Power Analyzer: Easily Identify Power Quality Issues Generate Detailed Reports Outlining Power Problems Utilize Smart Power

Severity Range of Power Problems

Report

TRANSIENTS

HIGH /LOW FREQ.

VOLTAGE SAGS

VOLTAGE SWELLS

POWER OUTAGES

04/11 4

Page 5: 04/111. 2 Benefits of Using a Power Analyzer: Easily Identify Power Quality Issues Generate Detailed Reports Outlining Power Problems Utilize Smart Power

Transients and Spikes - A momentary sharp increase or decrease in voltage. High voltage Transients( above 200V) are normally caused by lighting and low voltage transients( below 200V) are mostly caused motor-driven equipment such as your refrigerator, air-conditioner, Elevator.

04/11 5

Page 6: 04/111. 2 Benefits of Using a Power Analyzer: Easily Identify Power Quality Issues Generate Detailed Reports Outlining Power Problems Utilize Smart Power

Noise - Random Transients - electrical impulses that are carried along with standard AC current. Turning on the florescent lights overhead, your refrigerator, laser printers or working during a lightning storm can all introduce line noise into your systems.

04/11 6

Page 7: 04/111. 2 Benefits of Using a Power Analyzer: Easily Identify Power Quality Issues Generate Detailed Reports Outlining Power Problems Utilize Smart Power

Swells - Increase in Power line Voltage more than 110% of Nominal. Swells could be caused by external factors from power grid or by internal factors like switching off big loads from the circuit, loss or poor Neutral wire connections

04/11 7

Page 8: 04/111. 2 Benefits of Using a Power Analyzer: Easily Identify Power Quality Issues Generate Detailed Reports Outlining Power Problems Utilize Smart Power

Sags - Brief reductions in voltage, typically lasting from a cycle to few seconds . It could be caused by starting big loads and motor driven equipment or poor wiring condition.

04/11 8

Page 9: 04/111. 2 Benefits of Using a Power Analyzer: Easily Identify Power Quality Issues Generate Detailed Reports Outlining Power Problems Utilize Smart Power

Neutral-Ground Swell: Measurable AC voltage between neutral and Ground. It could be the result of Multiple loads connecting to the same circuit or inrush currents passing through the Neutral wire, like when Equipment starts up or Warms up. N-G Swells are typically caused by poor Neutral wire connections or connecting multiple loads to a branch circuit close to the capacity of the circuit.

04/11 9

Page 10: 04/111. 2 Benefits of Using a Power Analyzer: Easily Identify Power Quality Issues Generate Detailed Reports Outlining Power Problems Utilize Smart Power

Outage – Power outage or loss of the electricity supply.

04/11 10

Page 11: 04/111. 2 Benefits of Using a Power Analyzer: Easily Identify Power Quality Issues Generate Detailed Reports Outlining Power Problems Utilize Smart Power

POWER PROBLEMS

CAUSES OF POWER PROBLEMS

ACTIONS TO BE TAKEN

SMART POWER SOLUTIONS

Power Analysis Narrative Report

04/11 11

Page 12: 04/111. 2 Benefits of Using a Power Analyzer: Easily Identify Power Quality Issues Generate Detailed Reports Outlining Power Problems Utilize Smart Power

PRODUCT OVERVIEW

Venus UPS Series - Uninterruptible Power SupplyLine Interactive UPS with Transformer Based Filter (TBF)400VA to 800VA, power conditioner , battery backup, automatic voltage regulator, six 5-15R receptacles, RJ11 / RJ45, USB port, LED or LCD display.

SSP UPS Series - Uninterruptible Power SupplyUPS with Automatic Voltage Regulator and Pure Sinewave Output700VA to 3000VA, battery backup, line interactive, pure sinewave output, automatic voltage regulator, up to six 5-15R UPS protected receptacles, RJ11 / RJ45, DB9 (RS232) and USB port.

COPIER GUARDIAN – Transformer Based Filter (TBF) Electronic Power ConditionerAdvanced Computer-Grade Filtering for All Copier Installations15 and 20 Amp models available.

QF12 - SURGE FILTERPower Protection Device Offering Surge Protection and Computer Grade Filtering for Fax Machines, Smaller Printers, Mailing Machines12 Amp, Two 5-15R Receptacles, RJ11+RJ45.

SMART POWER ANALYZERIdentify Power Quality Issues and Generates Detailed Reports Outlining Power Problems and Solutions

AVR PLUS – AUTOMATIC VOLTAGE REGULATORProtects Copiers, Mailing Systems, ATMs and Other Electronic Equipment12, 15, 20 Amp, Two 5-15R Receptacles, RJ45.

DLC PLUS – DIGITAL LINE CONDITIONERProvide complete filtering of spikes, surges and line noise to safe levels3.4 - 20 Amp, Up to four 5-15R Receptacles, RJ45.