010 registration request message - rmds · 2015-02-16 · 010 registration request code economic...
TRANSCRIPT
010 Registration Request
010
Message
Specific
Information
Message Header
Phone One
Opt
010 MPRN Level
Information
Message
Customer Contact
Details
Opt
Customer Service
Special Needs
OptM
010 Register Level
Info
ReqM
Meter Point
Address
Req
Customer Name
Req
Phone Two
Opt
Fax
Opt
Address
Opt
Post Box
Opt
Notification
Address
Opt
Technical Contact
Details
Opt
Technical Contact
Opt
Party Contact
Details
Opt
Meter ID opt
Opt
Address
Opt
Phone One
Opt
Phone Two
Opt
Fax
Opt
Phone One
Opt
Phone Two
Opt
Fax
Opt
010 Registration Request
010 Valid Codes
Generation Unit Aggregation Code
It must only be used for export sites and be set to S = Separate, if gross import is aggregated to the Supplier independently of any export.
Change of Supplier Read Arrangement
CR – Customer Read. This indicates that the Supplier will provide a customer read to affect the changeover. The customer read may be provided as part of message 010 (see Meter Readings) or at a later date
using message 210. If Customer Reading is used for a Maximum Demand Meter Point then the registration will be rejected.
SC – Scheduled Read. This indicates that the Supplier will await the next scheduled reading date to affect the Change of Supplier using the scheduled reading.
SP – Special Read. This indicates that the Supplier requires the DSO to collect a special read to be used to affect the Change of Supplier.
MC – Meter Change. This indicates that the Supplier requires the DSO to perform a meter configuration change, the opening reads from which will be used to affect the Change of Supplier. If this is used then a
Meter Configuration Code must be provided as below.
DR - SoLR Read Arrangement. This is used when an alternate supplier is applying to take on a customer who was with a supplier who has defaulted and is no longer going to be active in the market. The code can
be used in QH CoS and will not cause the CoS to reject. If the code is not used during this scenario, the 010 will not be rejected.
MCC
MCC01 - Requestable at COS IF changing from MCC02 or MCC03
MCC02 - Requestable at COS IF changing from MCC01 only
Change of Supplier Estimate Acceptable (Flag)
Please Note: MRSO will disregard an Estimate Acceptable value of ‘true’ in the following circumstances:
1) A New Connection
2) A Change of Supplier for a QH Meter Point or an NQH Maximum Demand Meter Point
3) Where there has been no actual or customer read in the previous twelve months
Economic Activity Indicator
Please Note: A valid value for Economic Activity Indicator is required if the site is >30kva
Required Date
If the Change of Supplier Read Arrangement is specified as ‘CR’ (Customer Read) the Required Date must be:
Not earlier than three days before the date of receipt by MRSO of the registration request
Not later than forty days after the date of receipt by MRSO of the registration request
If the Change of Supplier Read Arrangement is specified as ‘SC’ (Scheduled Read) then the Required Date is not needed and is not validated.
In all other Change of Supplier scenarios the Required Date must be:
Not earlier than five days after the date of receipt by MRSO of the registration request
Not later than forty days after the date of receipt by MRSO of the registration request
Please Note: For a New Connection the Required Date is not validated.
Meter Point Address
The Supplier should use the address as published by DSO as this will aid validation. At a minimum ESB Networks require that sufficient information be provided to allow a site to be uniquely identified – 1 Main St,
Gorey, Co. Wexford can be more readily validated than simply 1 Main St. In addition, the address matching software will be unable to validate data if it is provided in an incorrect order, e.g. Co. Wexford, 1 Main St,
Gorey. If there is a change of address then, following confirmation of the registration, the Supplier should use message 013 to advise the change.
Optional/Mandatory; Although the following Data Items are optional, note the following caveats:-
Generation Unit Aggregation Code: Mandatory in case of a generator site
COS Read Arrangement: Mandatory if non-profile metering class and not eligible
COS Estimate Acceptable: Mandatory if non-profile metering class and not MD not eligible
Meter Configuration Code: Mandatory if a meter change is required
Required Date: Mandatory for special reads, profile and unmetered meter points
Message Specific informationMessage
010 Registration RequestSegment
Message
HeaderMessage Type
Req
Version Number
Req
Transaction
Reference
NumberReq
Timestamp
Req
Recipient ID
Req
Senders ID
Req
Message HeaderMessage
010 Registration RequestSegment
010 MPRN Level
InfoSupplier ID
Req
Meter
Configuration
CodeOpt
Market Participant
Business
ReferenceReq
MPRN
Req
Supply Agreement
Flag
Req
SSAC
Req
Supplier Unit ID
CoS Estimate
Acceptable
Opt
CoS Read
Arrangement
Opt
Change of Tenant
Legal Entity
Req
Economic Activity
Indicator
Opt
Required Date
Opt
Medical Equipment
Special Needs
DetailsOpt
Display on
Extranet
Opt
010 MPRN Level InformationMessage
010 Registration RequestSegment
Meter Point
Address Unit No.
Opt
Addr Line 1
Opt
Addr Line 2
Opt
House No.
Opt
Street
Addr Line 4
Addr Line 5
Postal Code
City
County Ireland
Country
Meter Point AddressMessage
Opt
Opt
Opt
Opt
Opt
Opt
Opt
010 Registration RequestSegment
Customer Name Title.
Opt
Last Name
Opt
First Name
Opt
Name Org1
Opt
Registered Company
Number
Opt
Trading As Name
Opt
Name Org2
Opt
Customer NameMessage
010 Registration RequestSegment
Customer
Contact DetailsEmail
Opt
Customer Contact DetailsMessage
010 Registration RequestSegment
Technical
ContactContact Name
Opt
Technical ContactMessage
010 Registration RequestSegment
Party Contact
DetailsE-mail
Opt
Party Contact DetailsMessage
010 Registration RequestSegment
Meter ID Opt Meter Category
Opt
Serial Number
Opt
Meter ID OptMessage
010 Registration RequestSegment
Meter Registration
Sequence
Opt
Timeslot
Reading
Register Type
Opt
010 Register
Level
Information
010 Register Level InformationMessage
Opt
Req
010 Registration RequestSegment
Customer
Service Special
Needs
Customer Service
Details Code
Req
Customer Service Special NeedsMessage
010 Registration RequestSegment
Phone One Number
Opt
Extn
Opt
Phone OneMessage
010 Registration RequestSegment
Phone Two Number
Opt
Extn
Opt
Phone TwoMessage
010 Registration RequestSegment
Fax Number
Opt
Extn
Opt
FaxMessage
010 Registration RequestSegment
Address C/O Name
Opt
Postal Code
City
Street
Req
County Ireland
Country
Unit No.
Opt
Addr Line 1
Opt
Addr Line 2
Opt
House No.
Opt
Addr Line 4
Opt
Addr Line 5
Opt
County/State
AddressMessage
Opt
Opt
Opt
Opt
Opt
010 Registration RequestSegment
Post Box PO Box Number
Req
Postal Code
Opt
City
Opt
Country
Opt
Post BoxMessage
010 Registration RequestSegment
Technical
Contact detailsE-mail
Opt
Technical Contact DetailsMessage
010 Registration RequestCode
Senders
ID
Senders ID
Click Here for Latest
Senders ID
List
Message Message Header
010 Registration RequestCode
Supplier
ID
Supplier ID
Click Here for Latest
Supplier ID
List
MessageMPRN Level
Information
010 Registration RequestCode
SSACA – Non Green
Generator
B – Eligible Customer
Supplier
C – Green Customer
Supplier
D – CHP Generator
D – Green VIPP
F - PES
G – Green Generator
H – CHP Supplier
J – VIPP Supplier
SSACMessageMPRN Level
Information
010 Registration RequestCode
Meter
Configuration
Code
MCC01 – 24 Hour
MCC02 – P/N
MCC03 – 24h+NSH
MCC04 – D/N+W
MCC05 – MDNm/PK
MCC06 – MDNm+Pk
MCC07 –
24H+NSH+W
MCC08 – 24h+W
MCC09 - Unmetered
MCC10 – QH2CH_IP
MCC11 –
QH4CH_IPXP
MCC50 - NONSTN
MCC51 – D/N+NSH
MCC53 – 2 X D/N
MCC57 – 24h+D
MCC58 – 24h+D/N
MCC59 – 24h+D/
N+W
MCC60 – 24h+D/
N+NS
MCC61 – 2x24h
MCC62 –
2x24h+NSH
MCC63 – 2x24h+D
MCC64 – 2x24h+W
MCC65 – 3x24hr
MCC67 – 3x24h+Day
MCC70 –
3x24H+NSH
MCC71 – 4x24H
MCC72 – 3x24H+W
MCC73 –
4x24H+NSH
MCC74 – 5x24H
MCC75 –
24H+2xNSH
MCC76 – 4x24H+W
MCC77 –
2x24H+W+NSH
MCC78 –
3x24H+W+NSH
MCC79 –
5x24H+NSH
Meter Configuration CodeMessageMPRN Level
Information
010 Registration RequestCode
CoS Read
ArrangementCR – Customer Read
DR – SoLR Read
Arrange met
MC – Meter Change
SC – Scheduled Read
SP – Special Read
CoS Read ArrangementMessageMPRN Level
Information
010 Registration RequestCode
Economic
Activity
Indicator
Economic Activity IndicatorMessageMPRN Level
Information
01 Agriculture, hunting and related service activities 28 Manufacture of fabricated metal products, except
machinery and equipment
64 Post and telecommunications
02 Forestry, logging and related service activities 29 Manufacture of machinery and equipment n.e.c. 65 Financial intermediation, except insurance and
pension funding
05 Fishing, f ish farming and related service activities 30 Manufacture of off ice machinery and computers 66 Insurance and pension funding, except compulsory
social security
10 Mining of coal and lignite; extraction of peat 31 Manufacture of electrical machinery and apparatus
n.e.c.
67 Activities auxiliary to f inancial intermediation
11 Extraction of crude petroleum and natural gas;
service activities incidental to oil and gas extraction,
excluding surveying
32 Manufacture of radio, television and communication
equipment and apparatus
70 Real estate activities
12 Mining of uranium and thorium ores 33 Manufacture of medical, precision and optical
instruments, w atches and clocks
71 Renting of machinery and equipment w ithout
operator and of personal and household goods
13 Mining of metal ores 34 Manufacture of motor vehicles, trailers and semi-
trailers
72 Computer and related activities
14 Other mining and quarrying 35 Manufacture of other transport equipment 73 Research and development
15 Manufacture of food products and beverages 36 Manufacture of furniture; manufacturing n.e.c. 74 Other business activities
16 Manufacture of tobacco products 37 Recycling 75 Public administration and defence; compulsory social
security
17 Manufacture of textiles 40 Electricity, gas, steam and hot w ater supply 80 Education
18 Manufacture of w earing apparel; dressing and
dyeing of fur
41 Collection, purif ication and distribution of w ater 85 Health and social w ork
19 Tanning and dressing of leather; manufacture of
luggage, handbags, saddlery, harness and footw ear
45 Construction 90 Sew age and refuse disposal, sanitation and similar
activities
20 Manufacture of w ood and of products of w ood and
cork, except furniture; manufacture of articles of
straw and plaiting materials
50 Sale, maintenance and repair of motor vehicles and
motorcycles; retail sale of automotive fuel
91 Activities of membership organizations n.e.c.
21 Manufacture of pulp, paper and paper products 51 Wholesale trade and commission trade, except of
motor vehicles and motorcycles
92 Recreational, cultural and sporting activities
22 Publishing, printing and reproduction of recorded
media
52 Retail trade, except of motor vehicles and
motorcycles; repair of personal and household
goods
93 Other service activities
23 Manufacture of coke, refined petroleum products
and nuclear fuel
55 Hotels and restaurants 95 Activities of households as employers of domestic
staff
24 Manufacture of chemicals and chemical products 60 Land transport; transport via pipelines 96 Undifferentiated goods producing activities of private
households for ow n use
25 Manufacture of rubber and plastic products 61 Water transport 97 Undifferentiated services producing activities of
private households for ow n use
26 Manufacture of other non-metallic mineral products 62 Air transport 98 Domestic
27 Manufacture of basic metals 63 Supporting and auxiliary transport activities;
activities of travel agencies
99 Extra-territorial organizations and bodies
010 Registration RequestCode
Medical
Equipment
Special Needs
Details
0003 – Life Support
0004 – Non Life
Support
Medical Institution
Medical Equipment Special Needs DetailsMessageMPRN Level
Information
010 Registration RequestCode
County
Ireland
County IrelandMessage AddressMeter Point
Address
AM Armagh LK Limerick ZA BHAILE ATHA CLIATHA ZN LIATROMA
AT Antrim LM Leitrim ZB AN CHABHAIN ZO LOCH GARMAN
CE Clare LS Laois ZC CHEATHARLACH ZP AN LONGFOIRT
CK Cork LY Londonderry ZD CHIARRAI ZQ LU
CN Cavan MH Meath ZE CHILL CHAINNIGH ZR LUIMNIGH
CW Carlow MN Monaghan ZF CHILL DARA ZS MHAIGH EO
DB Dublin MO Mayo ZG CHILL MHANTAIN ZT NA MI
DE Derry OY Offaly ZH AN CHLAIR ZU MHUINEACHAIN
DL Donegal RN Roscommon ZI CHORCAI ZV PHORT LAIRGE
DN Dow n SO Sligo ZJ DHUN NA NGALL ZW ROS COMAIN
FM Fermanagh TP Tipperary ZK NA GAILLIMHE ZX SHLIGIGH
GW Galw ay TY Tyrone ZL NA HIARMHI ZY THIOBRAID ARANN
KE Kildare WD Waterford ZM LAOISE ZZ UIBH FHAILI
KK Kilkenny WH Westmeath
KY Kerry WW Wicklow
LD Longford WX Wexford
LH Louth
010 Registration RequestCode
Country
Country
Message AddressMeter Point
AddressPost Box
AD Andorra CA Canada FO Faroe Islands JM Jamaica MP N.Mariana Islnd PW Palau TO Tonga
AE UAE CC Coconut Islands FR France JO Jordan MQ Martinique PY Paraguay TP East Timor
AF Afghanistan CD Congo GA Gabon JP Japan MR Mauretania QA Qatar TR Turkey
AG Antigua/Barbuda CF Central Afr.Rep GB United Kingdom KE Kenya MS Montserrat RE Reunion TT Trinidad,Tobago
AI Anguilla CG Congo GD Grenada KG Kyrgyzstan MT Malta RO Romania TV Tuvalu
AL Albania CH Sw itzerland GE Georgia KH Cambodia MU Mauritius RU Russian Fed. TW Taiw an
AM Armenia CI Ivory Coast GF French Guayana KI Kiribati MV Maldives RW Rw anda TZ Tanzania
AN Dutch Antilles CK Cook Islands GH Ghana KM Comoros MW Malaw i SA Saudi Arabia UA Ukraine
AO Angola CL Chile GI Gibraltar KN St Kitts&Nevis MX Mexico SB Solomon Islands UG Uganda
AQ Antarctica CM Cameroon GL Greenland KP North Korea MY Malaysia SC Seychelles UM Minor Outl.Isl.
AR Argentina CN China GM Gambia KR South Korea MZ Mozambique SD Sudan US USA
AS Samoa, American CO Colombia GN Guinea KW Kuw ait NA Namibia SE Sw eden UY Uruguay
AT Austria CR Costa Rica GP Guadeloupe KY Cayman Islands NC New Caledonia SG Singapore UZ Uzbekistan
AU Australia CU Cuba GQ Equatorial Gui. KZ Kazakhstan NE Niger SH St. Helena VA Vatican City
AW Aruba CV Cape Verde GR Greece LA Laos NF Norfolk Island SI Slovenia VC St. Vincent
AZ Azerbaijan CX Christmas Islnd GS Sth Sandw ich Is LB Lebanon NG Nigeria SJ Svalbard VE Venezuela
BA Bosnia-Herz. CY Cyprus GT Guatemala LC St. Lucia NI Nicaragua SK Slovakia VG Brit.Virgin Is.
BB Barbados CZ Czech Republic GU Guam LI Liechtenstein NL Netherlands SL Sierra Leone VI Amer.Virgin Is.
BD Bangladesh DE Germany GW Guinea-Bissau LK Sri Lanka NO Norw ay SM San Marino VN Vietnam
BE Belgium DJ Djibouti GY Guyana LR Liberia NP Nepal SN Senegal VU Vanuatu
BF Burkina-Faso DK Denmark HK Hong Kong LS Lesotho NR Nauru SO Somalia WF Wallis, Futuna
BG Bulgaria DM Dominica HM Heard/McDon.Isl LT Lithuania NU Niue Islands SR Suriname WS Western Samoa
BH Bahrain DO Dominican Rep. HN Honduras LU Luxembourg NZ New Zealand ST S.Tome,Principe YE Yemen
BI Burundi DZ Algeria HR Croatia LV Latvia OM Oman SV El Salvador YT Mayotte
BJ Benin EC Ecuador HT Haiti LY Libya PA Panama SY Syria YU Yugoslavia
BM Bermuda EE Estonia HU Hungary MA Morocco PE Peru SZ Sw aziland ZA South Africa
BN Brunei EG Egypt ID Indonesia MC Monaco PF Frenc.Polynesia TC Turksh Caicosin ZM Zambia
BO Bolivia EH West Sahara IE Ireland MD Moldavia PG Pap. New Guinea TD Chad ZW Zimbabw e
BR Brazil ER Eritrea IL Israel MG Madagascar PH Philippines TF French S.Territ
BS Bahamas ES Spain IN India MH Marshall Islnds PK Pakistan TG Togo
BT Bhutan ET Ethiopia IO Brit.Ind.Oc.Ter MK Macedonia PL Poland TH Thailand
BV Bouvet Island FI Finland IQ Iraq ML Mali PM St.Pier,Miquel. TJ Tajikstan
BW Botsw ana FJ Fiji IR Iran MM Myanmar PN Pitcairn Islnds TK Tokelau Islands
BY Belarus FK Falkland Islnds IS Iceland MN Mongolia PR Puerto Rico TM Turkmenistan
BZ Belize FM Micronesia IT Italy MO Macau PT Portugal TN Tunisia
010 Registration RequestCode
Title Br - Brother
Cllr - Councillor
Dr - Doctor
Fr - Father
Lady - Lady
Lord - Lord
Miss - Miss
Mr - Mr
Mrs - Mrs
Msgr - Monsignor
Ms - Ms
Prof - Professor
Rec - Reverend
Sir - Sir
Sr - Sister
TitleMessage Customer Name
010 Registration RequestCode
Meter Category
Meter CategoryMessage Meter ID
RM001 Single Tariff kWh RM228 Double Tariff kWh RM511 Single Tariff kWh RM621 C.T. Double Tariff kWh RM752 M.F.M.
RM002 Single Tariff kWh RM229 Double Tariff kWh RM512 Single Tariff kWh RM622 C.T. Double Tariff kWh RM753 Double Tariff Mechanical MD
RM003 Single Tariff kWh RM230 Double Tariff kWh RM513 Single Tariff kWh RM623 C.T. Double Tariff kWh RM754 M.F.M.
RM004 Single Tariff kWh RM231 Double Tariff kWh RM514 Single Tariff kWh RM624 C.T. Double Tariff kWh RM755 M.F.M.
RM005 Single Tariff kWh RM232 Double Tariff kWh 2 Element RM515 Single Tariff kWh RM625 C.T. Double Tariff kWh RM756 M.F.M.
RM006 Single Tariff kWh RM233 Double Tariff kWh 2 Element RM516 3-Phase Mechanical Single Tariff Meter RM626 C.T. Double Tariff kWh RM757 M.F.M.
RM007 Single Tariff kWh RM234 Double Tariff kWh RM520 Double Tariff kWh RM627 Electronic Double Tariff kWh RM758 M.F.M.
RM008 Single Tariff kWh RM235 Double Tariff kWh RM521 Double Tariff kWh RM640 C.T. Single Tariff Mech anical MD RM759 M.F.M.
RM010 Single Tariff kWh RM250 Electronic Double Tariff kWh RM522 Double Tariff kWh RM641 C.T. Single Tariff Mech anical MD RM760 M.F.M.
RM011 Single Tariff kWh RM251 Double Tariff kWh 2 Element RM523 Double Tariff kWh RM645 M.F.M. RM761 M.F.M.
RM020 Single Tariff kWh RM252 Electronic Double Tariff kWh RM524 Double Tariff kWh RM646 M.F.M. RM762 M.F.M.
RM021 Single Tariff kWh RM253 Electronic Double Tariff kWh (AMPY 5224E) RM525 Double Tariff kWh RM647 M.F.M. RM763 M.F.M.
RM022 Single Tariff kWh RM255 Electronic Multi rate kWh RM526 Double Tariff kWh RM648 M.F.M. RM764 M.F.M.
RM030 Single Tariff kWh RM256 Electronic Multi rate kWh RM527 Double Tariff kWh RM649 M.F.M. RM765 M.F.M.
RM031 Single Tariff kWh RM257 Electronic Multi Rate kWh RM528 Double Tariff kWh RM650 M.F.M. RM766 M.F.M.
RM032 Single Tariff kWh RM258 Electronic Multi Rate kWh RM529 Double Tariff kWh RM651 M.F.M. RM767 M.F.M.
RM033 Single Tariff kWh RM259 Electronic Multi Rate kWh RM530 Double Tariff kWh RM652 M.F.M. RM768 M.F.M.
RM034 Single Tariff kWh RM280 Hardw ired RM531 Double Tariff kWh RM660 C.T. Double Tariff Mechanical MD RM769 M.F.M.
RM035 Single Tariff kWh RM281 DLC RM532 Double Tariff kWh RM661 C.T. Double Tariff Mechanical MD RM770 Single Tariff kVArh
RM036 Single Tariff kWh RM300 Smart GPRS 3Ph WC 1-20(100) RM533 Double Tariff kWh RM662 C.T. Double Tariff Mechanical MD RM771 Single Tariff kVArh
RM039 Single Tariff kWh RM301 Smart DLC 3PH WC 0.25-5(80)A RM534 RM534 - Electronic Double Tariff kWh RM663 C.T. Double Tariff Mechanical MD RM772 Single Tariff kVArh
RM040 Single Tariff kWh RM302 Smart RF 3PH WC 0.5-10(100)A RM540 Mechanical MD RM664 C.T. Double Tariff Mechanical MD RM773 Single Tariff kVArh
RM041 Single Tariff kWh RM303 Smart RF 3PH WC 1-20(100)A RM541 Mechanical MD RM665 C.T. Double Tariff Mechanical MD RM774 Single Tariff kVArh
RM042 Single Tariff kWh RM304 Smart PLC 3PH WC 1-20(100)A RM542 Mechanical MD RM666 C.T. Double Tariff Mechanical MD RM775 Single Tariff kVArh
RM043 Single Tariff kWh RM350 Smart GPRS 3Ph WC 1-20(100) RM543 Mechanical MD RM667 M.F.M. RM776 Single Tariff kVArh
RM050 Electronic Single Tariff kWh RM351 Smart DLC 3PH CT 0.25-5(80)A RM545 M.F.M. RM670 C.T. kVArh RM777 Single Tariff kVArh
RM051 Single Tariff kWh Budget Controller RM352 Smart RF 3PH CT 0.5-10(100)A RM546 M.F.M. RM671 C.T. kVArh RM780 Summator
RM052 Single Tariff kWh Budget Controller RM353 Smart RF 3PH CT 1-20(100)A RM547 M.F.M. RM672 C.T. kVArh RM781 M.F.M. (PWRM/PML Ion 7600)
RM054 Single Tariff kWh Budget Controller RM354 Smart PLC 3PH CT 1-20(100)A RM548 M.F.M. RM673 C.T. kVArh RM782 M.F.M. (PWRM/PML Ion 7650)
RM055 Single Tariff kWh Budget Controller RM400 Single Tariff Current Transformer kWh RM549 M.F.M. RM674 C.T. kVArh RM783 M.F.M. (PWRM/PML Ion 7650)
RM056 Single Tariff kWh Budget Controller RM401 Single Tariff Current Transformer kWh RM550 M.F.M. (Elster A1140) RM675 C.T. kVArh RM784 Summator (PSI Siemens Maxsys V2737/R33)
RM066 Electronic Single Tariff kWh RM402 Single Tariff Current Transformer kWh RM551 M.F.M. RM676 C.T. kVArh RM785 M.F.M
RM067 Electronic Single Tariff kWh RM403 Single Tariff Current Transformer kWh RM552 M.F.M. RM720 Double Tariff kWh RMAB1 Single Phase Single Tariff kWh
RM068 Electronic Single Tariff kWh RM420 Double Tariff Current Transformer kWh RM553 M.F.M. RM721 Double Tariff kWh RMAB3 Single Tariff kWh
RM100 Smart GPRS 1PH WC 1-20(100)A RM421 Double Tariff Current Transformer kWh RM570 Single Tariff kVArh RM722 Double Tariff kWh RMB10 Single Phase Single Tariff kWh
RM101 Smart DLC 1PH WC 0.25-5(80)A RM422 Double Tariff Current Transformer kWh RM571 Single Tariff kVArh RM723 Double Tariff kWh RMB14 Single Phase Single Tariff kWh
RM102 Smart RF 1PH WC 0.5-10(100)A RM423 Double Tariff Current Transformer kWh RM572 Single Tariff kVArh RM740 Single Tariff Mechanical MD RMB15 Single Tariff kWh
RM103 Smart RF 1PH WC 1-20(100)A RM424 Double Tariff Current Transformer kWh RM573 Single Tariff kVArh RM741 Single Tariff Mechanical MD RMB16 Single Phase Single Tariff kWh
RM104 Smart RF 1PH WC 1-20(100)A RM425 Double Tariff Current Transformer kWh RM574 Single Tariff kVArh RM742 Single Tariff Mechanical MD RMB20 Single Phase Single Tariff kWh
RM105 Smart PLC 1PH WC 1-20(100)A RM426 Double Tariff Current Transformer kWh RM575 Single Tariff kVArh RM743 Double Tariff Mechanical MD RMB34 Single Tariff kWh
RM220 Double Tariff kWh RM500 Single Tariff kWh RM576 Single Tariff kVArh RM744 Double Tariff Mechanical MD RMB36 Single Tariff kWh
RM221 Double Tariff kWh RM501 Single Tariff kWh RM600 C.T. Single Tariff kWh RM745 Double Tariff Mechanical MD RMB40 Single Phase Single Tariff kWh
RM222 Double Tariff kWh RM502 Single Tariff kWh RM601 C.T. Single Tariff kWh RM746 Double Tariff Mechanical MD RMB45 Single Phase Single Tariff kWh
RM223 Double Tariff kWh RM503 Single Tariff kWh RM602 C.T. Single Tariff kWh RM747 Double Tariff Mechanical MD RMB60 Single Phase Single Tariff kWh
RM224 Double Tariff kWh RM504 Single Tariff kWh RM603 C.T. Single Tariff kWh RM748 Double Tariff Mechanical MD RMB63 Single Tariff kWh
RM225 Double Tariff kWh RM505 Single Tariff kWh RM604 C.T. Single Tariff kWh RM749 Double Tariff Mechanical MD RMB80 Single Phase Single Tariff kWh
RM226 Double Tariff kWh RM506 Single Tariff kWh RM617 C.T. kVArh RM750 Double Tariff Mechanical MD RMDT1 Double Tariff kWh
RM227 Double Tariff kWh RM510 Single Tariff kWh RM620 C.T. Double Tariff kWh RM751 Double Tariff Mechanical MD RMDT3 Double Tariff kWh
TKMTR Single Phase Single Tariff kWh
010 Registration RequestCode
Timeslot00D – 08- 23 Day
Consumption
00N – 23-08 Night
Consumption
ONR – 08-21 MD
Normal
OPK – 17-19 MD
Peak
24H – 24 Hour
Consumption
24M – 24 Hour MD
TimeslotMessage010 Register
Level Information
010 Registration RequestCode
Register Type 01 – 24hr
02 - Day
03 - Night
04 - NSH
05 - Wattless
06 – MD Normal
07 – MD Peak
08 – Cumulative MD
Normal
09 – Cumulative MD
Peak
50 – IMP QH (KW)
51 – IMP QH (kVAr)
52 – EXP QH(KW)
53 – EXP QH (kVAr)
Register TypeMessage010 Register
Level Information
010 Registration RequestCode
Customer
Service Special
Needs
0001 – Visually
Impaired
0002 – Speech
Impaired
0003 – Hearing
Impaired
0004 - Elderly
0005 – Language
Difficulty
0006 – Learning
Difficulty
0007 – Mobility
Impaired
Customer Service Details CodeMessageCustomer Service
Special Needs
010 Registration Request
History of ChangesMessage
Version Which Implemented Description of ChangeSource of Change
10.4 MCR 1155 Message format changed from ARIS to Document format.