00 cover front end-dec11 - xavier
TRANSCRIPT
XAVIER UNIVERSITYCampus Signage Implementation - Phase 1A
Volume 2 – Sign Standards Manual (Includes Technical Specifications)
January 2012
Roll • Barresi & Associates
48 Dunster Street
Cambridge, Ma 02138
617-868-5430
Roll • Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
Technical Specifications S.1
SECTION 10400 - EXTERIOR SIGNS
PART 1 - GENERAL
The pages that follow contain the Technical Specifications for the Xavier University Exterior Sign Standards. These Specifications should be used together with the Special Bid Provisions and the Sign Type Drawings to form a full description of the work re-quired to fabricate and install the signs.
1.1 REFERENCE STANDARDS
A. The work shall conform to the codes and standards of the following agencies as further cited herein:
1. AA: Aluminum Association, 818 Connecticut Avenue, NW, Washington, D.C. 20006.
2. ADAAG: Americans with Disabilities Act Accessibility Guidelines
3. ANSI: American National Standards Institute
4. ASTM: American Society for Testing and Materials, 1916 RaceStreet, Philadelphia, PA 19103 as published in “Compilation of ASTM Standards in Building Codes”
5. AWI: Architectural Woodworking Institute “Quality Standards”
6. NEC: National Electric Code - Latest Edition
7. PEI: Porcelain Enamel Institute, Inc., 1900 L Street NW,Washington,DC, 20036
8. UL: Underwriters Laboratories Inc. Publication Stock, 333 Pfingsten Road, Northbrook, IL 60062.
1.2 QUALITY ASSURANCE
A. The approved manufacturer shall have at least five years of experience in the type of work required; shall have a reputation for doing satisfactory work on time; and shall have recently successfully completed similar work.
B. The Drawings in this Bid Package are for design intent only. The Contractor is responsible for the proper engineering of all items. The internal structure, dimensions and specifications for all items shall be indicated in the Contractor’s shop drawings. Sign Contractor to engineer signs to proper level to withstand abuses of their environment.
C. The Contractor shall inform the Architect and Owner of any product and/or material deficiencies or incompatibilities that will prevent the signs from withstanding the conditions and abuses of their environment.
Roll • Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
Technical Specifications S.2
1.3 DELIVERY, STORAGE AND HANDLING
A. Deliver and store work under this Section in a manner to preventcracking or stress of components and to prevent mechanical damageor damage by the elements.
B. Deliver work under this Section to Site in ample time to avoid delay injob progress and at such times as to permit proper coordination of the various parts.
1.4 GUARANTEES
A. Manufacturers shall provide their standard guarantees for work under this Section. However, such guarantees shall be in addition to and not in lieu of all other liabilities which manufacturers and Contractors may have by law or by other provisions of the Contract Documents.
B. Unless otherwise noted in these specifications the Contractor shall guarantee all work under this Contract for a period of not less than one year, following completion and approval of the installation, during which time the Contractor shall maintain and service all signs provided under this Contract.
C. Contractor shall provide to the Owner, in writing, specific product warranties for all paint finishes, adhesive vinyl graphics and all ex-terior digital print graphics including banners and campus maps, as indicated in the Drawings and Specifications below.
1.5 PATTERNS & MOLDS
A. Patterns and molds for all cast elements must be turned over to the Owner at the conclusion of the project. Patterns and molds must be cleaned and repaired if necessary to allow the Owner to produce ad-ditional castings for new or replacement sheilds and finials.
PART 2 - PRODUCTS
2.1 MATERIALS
A. Aluminum
1. Aluminum plate for all signs shall conform to ASTM-B209, Alloy 6061-T6 to thickness indicated on drawings.
2. Aluminum extrusions for all signs shall conform to ASTM-B221 Alloy 6061-T6 to dimensions and thickness indicated on drawings.
3. Aluminum shall be of best commercial quality and their various forms shall be straight and true. There shall be no scratches, scars, creases or buckles.
4. Cut aluminum letters shall be water jet cut from sheets of thickness as indicated on the drawings. Letters shall be cut with
Roll • Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
Technical Specifications S.3
sharp corners, flat faces, and accurate profiles. Sand sides to smooth finish.
5. Fabricated aluminum letterforms shall be of solid aluminum sheeting. Letterforms shall be rigid, self-supporting and structur- ally sound. Use brackets and supports as required. All exposed welds shall be filed smooth with all tool marks removed by fine abrasive grain air blasting or other approved method.
6. Cast aluminum shall be solid aluminum, no scrap permitted. Cast aluminum shall be free of all porosity, with sharp corners, flat and accurate profiles. All exposed welds shall be filed smooth with all tool marks removed by fine abrasive grain air blasting or other approved method. All burrs and rough spots shall be removed and faces shall be polished to a uniform high luster finish. Alu-minum shall be mechanically sanded and degreased prior to receiving finish. All coatings shall be true to form, with no irregularities.
7. Patterns and molds for all cast elements must be turned over to the Owner at the conclusion of the project. Patterns and molds must be cleaned and repaired if necessary to allow the Owner to produce additional castings for new or replacement sheilds and finials.
8. Where aluminum is shop fabricated, all joints, returns and the like shall be properly joined together and welded edges shall be ground smooth to proper aluminum finish.
9. Aluminum in contact with dissimilar metals shall have bituminous or other protective coating to prevent electrolytic action.
B. Steel
1. Structural steel materials, details and workmanship shall conform to the requirements of the latest edition of the A.I.S.C. Specifica-tions for the Design, Fabrication, and Erection of Structural Steel Buildings.
2. All steel shall be galvanized in accordance with ASTM-A123.
C. Bronze/Brass/Copper
1. Bronze shall be solid bronze made of pre-alloyed ingots, free of all porosity with sharp corners and flat accurate profiles. All burrs and rough spots shall be removed and faces shall be polished to a uniform high lustre. Bronze shall be mechanically sandedand degreased prior to recieving finish. All coatings shall be true to form with no irregularities.
2. Cast bronze shall be solid bronze, cast of pre-alloyed ingots [no scrap metal permitted]. Alloy shall match Designer’s sample. Bronze shall be cast in sizes and thicknesses as shown on draw-ings. Sand sides to a smooth finish.
Roll • Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
Technical Specifications S.4
3. Plate bronze plaques shall be saw-cut from plate stock, in alloy to match Designer’s sample, of thickness and sizes as indicated on drawings. Sign parts shall be cut with sharp corners, flat faces and accurate profiles; belt polish faces to uniform finish as noted in drawings. Sand sides to a smooth finish.
4. Bronze letterforms / artwork shall be water jet cut from a sheet as indicated on drawings. Letters shall be saw cut with sharp corners, flat faces and accurate profiles. Sand sides to a smooth finish.
5. Fabricated bronze letterforms shall be solid bronze sheeting, Al-loy to match Designers sample. Letterforms shall be rigid, self-supporting and structurally sound. Use brackets and supports as appropriate. All exposed welds shall be filed smooth with all tool marks removed by fine abrasive grain or air blasting or other ap-proved method.
6. Finishes to be as follows: Oxidized - Medium
All bronze shall have clear acrylic lacquer finish, applied evenly, free from runs and imperfections.
D. Welding
1. Welding materials and practices shall conform to the requirements of the latest edition of American Welding Society code for steel and aluminum. Shop welders shall be certified by AWS. Welding rods shall be of a composition compatible to the base metal being welded. Welding rods for structural steel shall be an E70 category. Welding of aluminum shall be the MIG process, using ER-5356 wire.
2. Fabrication shall be accomplished using the highest standards of workmanship. All pieces shall be saw cut and carefully fit together. All visible connections shall be full welded and ground flush and smooth. All visible surfaces and connections shall be without visible grounding marks, surface differentiation or variation.
E. Hardware
1. Anchor bolts shall conform to ASTM-A576 with a minimum yield strength of 50,000 PSI. Hexagonal nuts and washers shall be furnished with each bolt.
2. High strength bolts (other than anchor bolts), nuts and washers shall conform to ASTM-A325.
3. Where mechanical fasteners and hardware are required, they shall be of adequate thickness, length and construction to proper-ly secure the sign unit. Any visible portion of any mounting device shall be finished to match adjacent sign surface, unless otherwise specified.
Roll • Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
Technical Specifications S.5
4. Metal fasteners and hardware in contact with dissimilar metals shall have a protective coating or neoprene shields to prevent electrolytic action.
5. Lock cylinders shall be interchangeable core pin tumblers with nickel silver keys; all locks to be keyed alike. Locks to be flush with adjacent cabinetry as indicated in the Drawings. Pained fin-ish to match color and finish of adjacent cabinetry. Provide five sets of keys.
F. Glass
1. Tempered glass shall be clear float glass conforming to FederalSpecification DD-G-001403, Kind FT, Condition A, Type 1, Classas required, Quality 3. All tempered glass shall be stress testedin the factory prior to installation. Tempering shall be by TempGlass Co., Perrysburg, Ohio, or approved equal.
G. Acrylic
1. Acrylic shall be cast acrylic sheet that is optically clear, has highimpact resistance, weather resistance, formability and machine-ability.
2. Acrylic plastic shall be Plexiglas G with smooth finish, Rohm and Haas, Philadelphia, PA, or approved equal.
3. Saw-cut acrylic letters shall be cut from acrylic sheet, thickness as indicated on Drawings. Letters shall be saw-cut with sharp corners, flat faces and accurate profiles. Polish sides to a smooth finish.
H. Polycarbonate
1. Polycarbonate sheet shall be formed polycarbonate clear or witintegral color.
2. Polycarbonate over laminate shall be .015 Lexan Film 8A35-112 with velvet finish first surface, polished finish second surface, GE Plastics.
I. Vinyl
1. Vinyl for computer-cut letters shall be Scotchcal as manufactured by 3M Co., St. Paul, MN, or approved equal.
2. Vinyl shall have a matte finish with a .003 to .006 film thicknessand shall match colors as shown on Drawings.
3. Provide written warranties for all die-cut vinyl products.
Roll • Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
Technical Specifications S.6
J. Reflective Sheeting
1. Reflective Sheeting shall conform to Federal Highway Administration Standard FP-79 Table IV [engineer grade] as manufactured by 3M Co., St. Paul, MN, or approved equal.
2. Sheeting shall have pressure sensitive adhesive backing and shall be applied without necessity of additional adhesive coats on either the backing or application surface. Surface shall be degreased and etched according to manufacturer’s specification prior to application.
3. Provide written warranties for all die-cut vinyl products.
K. Large Format Digital Graphics
1. Imaging/Prepress
a. The Contractor will be provided with final ‘camera ready’ artwork for all map and banner graphics by the Owner. Colors will be assigned Pantone color numbers and images will be high-resolution photographs.
b. All editing of colors and images (i.e. contrast, color balance, etc...) must be approved by the Designer and the Owner. The Contractor shall make all adjustments and printer calibrations necessary to achieve accurate spot color matches and correct color balance and saturation values for photographic images.
c. All artwork to be returned within two months of fabrication/installation completion. All artwork must be returned via tracked overnight mail.
2. Output
a. Campus Maps
1) Graphics shall be produced using a continuous ink-jet print-ing machine suitable for the printing of large-format, full-color images and text directly from a digital file, one step directly to substrate. The print resolution must be 720-dpi minimum. The ink-jet output device shall have a minimum width capacity of 63 inches with the capability of printing on the following sub-strates: vinyl (frontlit, backlit, adhesive), net (thin and thick), Tyvek, panaflex, silk, canvas, vinyl coated nylon (Vylon), and nylon.
2) Inks and solvents shall be durable for outdoor use and provide a minimum of 2 years of colorfastness without the use of protective coatings or laminates. Colors shall be derived from four-process color CMYK pigments with a 6 million color combination range. Black shall be process black only.
Roll • Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
Technical Specifications S.7
b. Vinyl Banners
1) Graphics shall be produced using 3M Scotchprint 2000 imaging system directly from a digital file or approved equal. Image shall be output onto 8620 white, 2-mil Controltac pres-sure sensitive film for banners and 8640 white 4-mil Controltac pressure sensitive film for rigid surface mounting. Minimum output resolution shall be 400 dpi. Images on Controltac shall be sealed with 8910 or 8911 over laminating film.
2) For banners, the Scotchprint image will be applied to 3M Panaflex substrate. 2-sided banners will have a blackout layer between the banner faces to insure opacity.
3) Inks and solvents shall be durable for outdoor use and pro-vide a minimum of 1.5 years colorfastness without the use of protective coatings or laminates.
4) Nylon Flags and Banners
5) Graphics shall be produced using a four-color process electrostatic plotter at 300dpi, output directly from a digital file, onto dialectric transfer print paper. Dialectric transfer print paper shall be heat transferred to a 14oz. indoor/outdoor, opaque, smooth two-sided receiver that is vinyl reinforced with 100% polyester blackout. The heat transferred electro-static transfer print and vinyl banner receiver media are water separated for carrier sheet removal. The unfinished separated banner is then overlaminated with 1.5 mil matte over laminat-ing film.
6) Inks and solvents shall be durable for outdoor use and provide a minimum of 2 years colorfastness without the use of protective coatings or laminates.
c. Photographic Durst Lambda Print
1) Graphics shall be full color continuous tone produced directly from a digital file using a Durst Lambda photographic printer onto archival Ilford-Cibachrome paper with a minimum colorfastness rating of 2 years without protective coatings.
2) Printer shall have a minimum width capacity of 50” with a minimum resolution of 720-dpi. Prints shall be laminated with a .015 Lexan film with a velvet finish on the first surface and polished finish on the second surface.
3. The Contractor shall provide the Owner with a warranty in writing guaranteeing a minimum of 2 years color fastness and 2 years product durability. There shall be no delamination, buckling, warp-ing or deterioration during that time frame.
Roll • Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
Technical Specifications S.8
L. Banner Poles
1. Banner poles to be as manufactured by Pole-Tech, Inc., East Setauket, NY, 800-633-6733, or approved equal.
2. Banner bracket arms to be manufactured by Kalamazoo Banner Works, Kalamazoo, MI, 800-525-6424, or approved equal.
3. All load requirements to be verified by manufacturer. Require-ments to include, but not be exclusive to: design load, snow load, wind load and uplift load, as required.
4. The Contractor shall provide documentation that pole assembly and bracket arms assembly meets all building codes, and shall provide complete description of pole system in terms of materials, dimension, i.e. pole diameter and taper, wall thickness and footing system.
M. Sign Mounting Brackets
1. Brackets shall be Sign Fix Universal Cantilever brackets, by Sign Fix Inc., Pine Bush, NY, fabricated from stainless steel Type 304 with extruded sign support “T” section. Aluminum Alloy 6061-T6.
2. Stainless steel strappings shall be “Band It” as distributed by Hinds & Coon Co., Boston, MA, or approved equal. Strapping shall be painted to match light pole.
N. Adhesives
1. Where adhesive mounting techniques are specified, the Contrac-tor shall use adhesives specifically designed for compatibility with the base materials and the desired adhesive strength. All adhe-sives shall be tested on site. All adhesives shall be indicated in the shop drawings.
2. Surfaces on which sign is to be installed using adhesive shall be free of grease, oil, or any other residue.
3. Foam tape shall be 1/32” thick, high density open cell double coated polyurethane foam tape, Scotch Mount #4016 by 3M Co., St. Paul, MN, or approved equal.
4. VHB tape shall be double coated acrylic foam tape #4920 by 3M Co., St. Paul, MN, or approved equal.
5. Provide necessary amounts of clear silicone sealant or grout for use in pin mounting.
O. Electrical
1. All electrical items - light fixtures, lamps, wiring and appurtenanc-es necessary for the signs shown in the drawings shall be pro-vided and installed as part of this Contract. All specific electrical
Roll • Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
Technical Specifications S.9
equipment required by product codes or building codes, such as item grounds, disconnect switches, insulation etc. shall be shown and noted in the shop drawings.
2. The Contractor shall insure that the graphic area of each illumi-nated sign is illuminated evenly, with no hot spots, light leaks or drop-off of light intensity at the borders of the graphic area. The Contractor shall insure that there are no light leaks on the sign face or around the perimeter of the sign frame.
3. All electrical items shall bear an Underwriter’s label.
4. All silk screening processes shall be approved by the Designer prior to fabrication.
P. Masking and Spraying
1. Graphic mask shall be assembled on sign panel or wall in a pro-fessional manner prior to spraying. No hand-cut masks shall be used.
2. Masking and spraying shall be done carefully so as not to leave bleeding or rough edges at painted surfaces. All edges and corners of the finished graphics shall be true and clean. Graphics with rounded positive or negative corners will not be accepted.
3. Spray guns used for artwork shall be airless type as approved. All graphic work shall receive at least two coats of paint.
Q. Sandblasting
1. All sandblasting and tinting to be executed by an artisan with experience showing the highest standards. Letterforms shall be sharp and clean with no imperfections. Protect adjoining and ad-jacent surfaces from damage with Homosote or other hard board. Clean up shall occur on same day as sandblasting.
2. Glass
a. Sandblasting on glass shall be executed on tempered glass using a fine silver grit. Graphics on pre-cut friscut shall be sharp and clean and shall be bonded securely to glass prior to blasting. Stencil shall be removed with standard solvent and cleaned with water. Sandblasted area shall be clean and free of imperfections.
b. Following blasting the graphics shall be sprayed with Trans-parent Gray Lithichrome Shadow cut 50% with lacquer thinner, Cleveland Lithochrome Co., Fort Scott, KS, or equal.
3. Stone
a. Sandblasting on stone shall be executed with an abrasive that contains less than 1% silica at 80 - 120 lb. pressure. Graph-ics on pre-cut friscut shall be sharp and clean and shall be
Roll • Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
Technical Specifications S.10
bonded securely to stone prior to blasting. Following blasting any “pockets or notches” due to irregularities or aggregates in material shall be carefully filled and smoothed over prior to re-moval of mask. Stencil shall be removed with standard solvent and cleaned with water. Sandblasted area shall be clean and free of imperfections.
b. Following blasting the graphics shall be sprayed with Trans-parent Gray Lithichrome Shadow to match Designer’s Sample, Cleveland Lithochrome Co., Fort Scott, KS, or equal.
R. Chiseled Stone
1. Letters shall be hand cut or chiseled with pneumatic chisel into granite in typestyle as specified on Drawings with “vee” cut sec-tion.
2. All chiseling and tinting to be executed by an artisan with experi-ence showing the highest standards. Letterforms shall be sharp and clean with no imperfections.
3. Letters to be tinted with Transparent Grey Lithichrome Shadow by Cleveland Lithichrome, Inc., Fort Scott, Kansas. Tint to be se-lected by Architect. Lithichrome to match Designer’s Sample, and applied with airbrush.
S. Typeface
1. All copy shall be in the typefaces shown in the graphic standards to match the letterforms shown in the Detail Drawings.
2. All types of graphics - engraved, photo-polymer, saw-cut, vinyl, silk screened, etc. shall be made with the Adobe fonts by Adobe Inc., Mountainview, CA, specified using a PC or Mac link to the final graphic output device.
T. Typesetting
1. All typeset messages shall be prepared on a Macintosh or IBM PC. Letterforms shall match the samples shown in the drawings.
2. Standard letter spacing and standard word spacing shall be ap-proved by Designer for all fonts before final manufacture.
3. Typical type and symbol layout for each sign type is indicated on the Design Drawings. All type shall be placed according to the dimensions shown on the drawings. Should any design conflict occur in the fabrication of the signs; i.e., type not fitting, it shall be brought to the attention of the Designer.
U. Windmaster Signs
1. Moveable freestanding signs shall be the Windmaster sign by Marketing Displays International, Farmington Hills, MI.
Roll • Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
Technical Specifications S.11
2.2 FINISHES
A. Paints
1. Paints for metal signs shall be finished with acrylic polyurethane semi-gloss enamel as manufactured by Matthews Paint Co., Wheeling, Ill., or approved equal.
2. All surfaces shall be cleaned, primed and pre-treated according to manufacturer’s specifications and noted in Shop Drawings as part of the finished surface work.
B. CONCRETE FOOTINGS
1. Site Preparation and Restoration
a. Within existing concrete sidewalks the Contractor shall de-molish an area of concrete sidewalk sufficient to accomplish required construction for concrete footings. Disturbance to ex-isting conditions shall be held to the absolute minimum neces-sary to accomplish the work. Areas disturbed shall be restored and finished flush with sidewalk
2. Materials and Construction
a. Air-entrained Class D cement concrete masonry shall comply with Section 901 of the Commonwealth of Massachusetts, De-partment of Public Works, “Standard Specifications for High-ways and Bridges,” 1973 and current amendments.
b. Concrete shall have a minimum compressive strength of 3,000 psi at 28 days.
c. Installation of Class D cement concrete including formwork, finishing, protection and curing of concrete shall conform to requirements of Section 901 of the “Standard Specifications”.
d. Reinforcing bars shall be deformed bars rolled from new billet steel conforming to ASTM-A615, Grade 60. Include tie wire and accessories as required.
e. Grouting called for on the drawings shall be performed with Five Star Grout as manufactured by U.S. Grout Corporation or approved equal. The grout must show no shrinkage under ASTM C-827 and CRD-C-621, and must contain no expansive cements or metallic powers such as aluminum or iron filings. Preparation of surfaces, mixing, placing and curing of grout shall be in accordance with manufacturer’s recommendations.
Roll • Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
Technical Specifications S.12
PART 3 - EXECUTION
3.1 PREPARATION AND INSPECTION
A. All surfaces to receive work shall be prepared and finished by the respective trades. The Sign Contractor shall notify the Designer if surfaces or openings are not satisfactory to receive this work. Com-mencement of work by Sign Contractor shall constitute acceptance of conditions and surfaces. Subsequent work not accepted by the De-signer shall be replaced at no additional cost to the Owner.
B. Prior to installation of all sign types each type shall be verified in field as to meet field conditions. Sign Contractor shall notify Architect if cor-responding room name and number signs do not meet field conditions.
C. All work shall be performed in accordance with a written schedule agreed on by Owner, Contractor, Designer and Sign Installer. In any case where work cannot be completed on schedule, the Contractor shall supply temporary signs at no additional expense to the Owner.
D. All work shall be subject to inspection and approval by the Designer in the shop or field at any reasonable time. Provide at least 72 hours notice for Designer’s inspection of complete fabricated signs before delivery.
3.2 WORKMANSHIP, PERFORMANCE
A. All work shall present clean, straight sharply defined lines, free from defects impairing strength or durability, and shall be performed in a shop where the grade of work is of a quality acceptable to the De-signer. All work shall be installed plumb, straight, square, level and in proper elevation plane, location, and alignment with other work. All work shall be designed for adjustment to field variations, fitted with proper joints and intersections, and adequately anchored in place. All workmanship and finishes shall be of best quality in every particular, strictly in accordance with best practice. All work shall be complete in every detail. Finish work shall be subject to approval by the Designer.
3.3 INSTALLATION / APPLICATION / ERECTION
A. Members shall be shop-fabricated, and where practical, all work shall be delivered to the site completely assembled. All joints of such fabri-cated work shall be completely smooth without apparent marks show-ing throughout the finish. All work “broken down” shall be erected so that all parts fit accurately with hairline joints.
B. Unless otherwise shown on the Drawings, all members shall be continuous lengths without seams. Work shall be formed to profiles indicated on the Drawings.
Roll • Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
Technical Specifications S.13
C. Where material lengths require joints, all joints shall be flush. Similar materials at joints shall be either bonded or welded together, or shall be lap jointed to provide for expansion. All joints to be lightproof.
D. Protect adjacent or adjoining surfaces and work from damage during installation in this section.
E. Work shall be designed and anchored so that work will neither be dis-torted nor the fasteners overstressed from expansion and contraction of metal or other materials as applicable.
3.4 CLEANING AND PROTECTION
A. At completion, all work shall be checked over, re-adjusted, and left in first class condition. Signs shall be cleaned with non-abrasive clean-ing agents without damage to sign surfaces.
B. Manufacturer shall provide Owner with information on cleaning and maintenance recommendations for all signs.
C. Names, stamps and decals of manufacturers, installers or maintainers of signs shall not be visible in the finish work.
3.5 PERMITS
A. Sign Contractor shall obtain all permits required by Local Authorities for installation of signs.
3.6 AS-BUILT DRAWINGS
A. Sign Contractor to provide as-built drawings for building engineer/man-agement use.
END OF SECTION 10400
Roll • Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 0.1List of Drawings
– List of Drawings 0.1
– Graphic Standards - Colors 0.2
– Graphic Standards - Typography 0.3 - 0.4
– Graphic Standards - Symbols 0.5 - 0.6
– Graphic Standards - Sign Setback Guildlines 0.7
100A Hoff Pillars 100A.1
101A Trailblazer, Post and Panel 101A.1 - 101A.3
101B Trailblazer, Mounted to Existing Pole 101B.1 - 101B.3
110 Vehicular Directional, Double Post 110.1 - 110.4
111 Vehicular Directional, Single Post 111.1 - 111.4
112 Vehicular Directional, Temporary Events 112.1 - 112.2
115 Parking ID, Large, Single Post 115.1 - 115.4
116 Parking ID, Small, Single Post 116.1 - 116.3
117 Parking Lot Number Panel 117.1 - 117.3
120 Campus Information Kiosk 120.1 - 120.4
121 Campus Map Display 121.1 - 121.4
123 Pedestrian Directional, Double Post 123.1 - 123.4
124 Pedestrian Directional, Single Post 124.1 - 124.3
130 Freestanding Building ID, Large, Double Post 130.1 - 130.5
131 Freestanding Building ID, Large, Single Post 131.1 - 131.5
132 Freestanding Building ID, Small, Double Post 132.1 - 132.6
133A Building ID Plaque, Large 133A.1 - 133A.4
135A Building ID Letters, Large 135A.1 - 136A.3
135B Building ID Letters, Medium 135B.1 - 135B.5
135C Building ID Letters, Small 135C.1 - 135C.3
136 Refurbish Letters 136.1
137 Building ID Letters on Panel 137.1 - 137.3
138 Building Entrance Graphics 138.1 - 138.4
140 Regulatory 140.1 - 140.3
141 Parking Regulatory 141.1 - 141.3
142 Traffic Control 142.1 - 142.4
143 Street Name Sign 143.1 - 143.4
144A Acessible Path Sign, Post & Panel 144A.1 - 144A.3
144B Acessible Path Sign, Wall Mounted 144B.1 - 144B.2
150 Vehicular Light Pole Banner 150.1
151 Pedestrian Light Pole Banner 151.1
152 Street Pole Banner 152.1 - 152. 2
153 Flag Pole Banner, Halyard 153.1
154 Flag Pole Banner, Fixed Bracket 154.1 - 154.2
155A Building Mounted Banner 155A.1 - 155A.3
155B Building Mounted Banner, Vertical Strip 155B.1 - 155B.3
Sign Type Description Dwg. #s
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 0.2Graphic StandardsColors
Dark Blue to match Pantone 648c
Dark Gray to match RAL 7022, Umbragrau
Light Gray to match RAL 7044, Seidengrau
Matte White 3M Scotchcal, 220-20 Matte White
Medium Blue to match Pantone 647c
Parking Blue 3M Scotchlite 280-76, Light Blue
Reflective White 3M Scotchlite 280-10, White
Red 3M Scotchlite 280-82, Ruby Red
Silver Mattews Paint Company 30136, Brushed Aluminum
White Mattews Paint Company 11477, Natural White
Note: All paint finishes for exterior signage are semi-gloss unless otherwise noted in the drawings
Color Name Specification
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 0.3Graphic StandardsTypography
A B C D E F G H I J K L M N O P Q R S T U V W X Y Za b c d e f g h i j k l m n o p q r s t u v w x y z0 1 2 3 4 5 6 7 8 9
A B C D E F G H I J K L M N O P Q R S T U V W X Y Za b c d e f g h i j k l m n o p q r s t u v w x y z0 1 2 3 4 5 6 7 8 9
ALUMNI CENTER
Standard Letterspacing - All CapsAdobe Illustrator Optical Kerning, Track 50
Standard Letterspacing - All CapsAdobe Illustrator Optical Kerning, Track 100
Bembo Semibold
Bembo Regular
Main Campus
Standard Letterspacing - Upper and Lower CaseAdobe Illustrator Optical Kerning, Track 25
MICHA EL J. CONATON
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 0.4Graphic StandardsTypography
A B C D E F G H I J K L M N O P Q R S T U V W X Y Za b c d e f g h i j k l m n o p q r s t u v w x y z0 1 2 3 4 5 6 7 8 9
EVENT ONLY
Standard Letterspacing - All CapsAdobe Illustrator Optical Kerning, Track 75
Frutiger Bold
Sycamore
Standard Letterspacing - Upper and Lower CaseAdobe Illustrator Optical Kerning, Track 25
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 0.5Graphic StandardsSymbols
Logotype - white or light background
Logotype - dark background
Note: Logotype shown has adjustments to improve legibility for signage applications– this logotype for use on signage only.
Dark Blue
Silver
White
Dark Blue
SilverWhite
White
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 0.6Graphic StandardsSymbols
Arrow Orientation – Flush Left Sign Layouts Arrow Orientation – Centered Sign Layouts
Parking - Sign Panels
Decorative Pattern
No Parking - All Conditions
Accessible - Entrance Doors
No Smoking - All Conditions
Accessible - Sign Panels Parking Zone Arrow
Black outline does not print (typ.)
Align arrow with bottom left for flush left sign layouts
Align arrow with bottom center for centered sign layouts
CL
Note: for reference only - not for reproduction.Artwork to be provided by Designer on disk.
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 0.7Graphic StandardsSign Setback Guidelines
Double Posted Sign
Edge of road
Single Post Sign (Tavern Style)
Edge of road
Edge of road
Single Post Sign (Centered Post)
2' - 0"
18" Min.
2' - 0"
18" Min.
3' - 0"
Minimum
Shown below are standard setbacks for signsalong campus roads. If field conditionsdo not allow for the setbacks indicated, obtainapproval from Xavier University prior to installation.
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 100A.1
Scale: 3/16" = 1' - 0"
Location Elevation
Reference Photo (Pillar Under Construction)
Sign Type 100AHoff Pillars
Sign Type 101A - Hoff Pillars
Typestyle: Bembo Semibold
Color: Transparent Gray Lithichrome Shadow
Description: Lettering hand-carved into limestone, infilled with lithochrome, pin-mounted to existing pillar with adhesives as required.
FF OO UU NN DD EE DD 1188 3311
Scale: 1 1/2" = 1' - 0"
Layout
1'-
10
3/4"
Pla
que,
VIF
1' -
11
1/4"
Fie
ld V
erify
2'- 8 3/4" Plaque, VIF
1/4"
2 5
/8"
2 5
/8"
4.5"
4"5"
2 1/
2"1
1/2"
1/4"
1/4" 1/4"
1/4"
1/4"
Scale: 1 1/2" = 1' - 0"
Section
Existing cast stonepanel
Existing cast stone panel
1 1/4" thick limestone,finish tbd
Pin mount withadhesives as required
Hand-carved vee-cut lettersinfilled with Transparent GrayLithichrome Shadow
C Text and PlaqueL
XAVIERUNIVERSITY
F O U N D E D 18 31
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 101A.1
Scale: 3/4" = 1' - 0"
Elevation
Sign Type 105A - Trailblazer, Post and Panel
Artwork: Logotype to be provided.
Colors: Sign Post - Dark Gray Sign Panel - Dark Blue Text & Arrow - Reflective White Decorative Pattern - Medium blue
Description: Single sided aluminum sign panel and post, painted with masked and sprayed decorative pattern and reflective vinyl text.
Criteria: This sign is used for providing directions to the University and the Cintas Center along roadways leading to the campus from major highways and where a light pole or utility pole isn’t present.
Signs should be located prior to an intersection, a distance as determined in the field. The Cintas Center message, when provided, should always be accompanied with the “Xavier University” message.
Sign Type 101ATrailblazer, Post and Panel
2'-2"
2'-9
"7'
-0"
Decorative
Pattern: masked
and sprayed
Sign Panel:
painted aluminum
with reflective
vinyl text
Sign Post: 3"
diameter aluminum,
painted
Concrete footing as required
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 101ATrailblazer, Post and Panel
Date 101A.23" diameter aluminum post
painted Dark Gray. Provide Post
Cap at top of post
Threaded rod stud welded to bracket and fastened to post
with acorn fastener. Fastener painted to match post
Aluminum channel the entire length of panel, welded to
back of panel and painted Dark Blue
1/8” aluminum sign panel mechanically fastened to
post with required hardware. Back of panel painted
Dark Blue
Half Size
Horizontal Section
3" diameter aluminum post
Restore surface material to original
condition. See Technical Specifications
1 1/2" = 1’ - 0"
Post Cap, Base and Footing Detail
Stainless Steel thru bolt
Gravel backfill
Reinforced Concrete
footing as required
9"
3'-
6"
Grade
Galvanized steel post sleeve
with painted coating
1/8" thick aluminum post cap,
weld and grind smooth,
painted to match post
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 101ATrailblazer, Post and Panel
Date 101A.3
Scale: 1 1/2" = 1' - 0"
Layout 1
Scale: 1" = 1' - 0"
Layout 2
Scale: 1" = 1' - 0"
Layout 3
2'-2"
1 5/8"2
5/8
"4
3/4
"2
5/8
"5
1/8
"2 5
/8"
2'-
9"
6 3
/8"
R = 1/4" typical
Cintas Center
Cintas Center
2 5
/8"
2 1
/8"
1"
1 1
/4"
1'- 10 1/8" ruleEQ EQ 1 1/2"
2 3
/4"
2 3
/8"
2 1
/8"
2 7
/8"
5 1
/8"
1/8" Rule
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 101B.1Sign Type 105B - Trailblazer, Mounted to Existing Pole
Artwork: Logotype to be provided.
Colors: Sign Panel - Dark Blue Text & Arrow - Reflective White Decorative Pattern - Medium Blue
Description: Single sided aluminum sign panel, painted with masked and sprayed decorative pattern and reflective vinyl text. Mounted to existing pole.
Criteria: This sign is used for providing directions to the University and the Cintas Center along roadways leading to the campus from major highways: where a light pole or utility pole exists.
Signs should be located prior to an intersection, a distance as determined in the field. The Cintas Center message, when provided, should always be accompanied with the “Xavier University” message.
Scale: 3/4" = 1' - 0"
Elevation
Sign Type 101BTrailblazer, Mounted to Existing Pole
2'-2"
2'-9
"7'
-0"
Existing Sign Post
Decorative
Pattern: masked
and sprayed
Sign Panel:
painted aluminum
with reflective
vinyl text
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 101BTrailblazer, Mounted to Existing Pole
Date 101B.2
Half Size
Horizontal Section
3/4" Stainless Steel Strapping
Stainless Steel bracket to matchSignFix Bracket HPN177, two (2) per panel
1/8" thk. Alum. sign panel
SS threaded bolt and washer ptd.to match sign panel
Existing Round, square oroctagonal Utility Pole
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 101BTrailblazer, Mounted to Existing Pole
Date 101B.3
Scale: 1 1/2" = 1' - 0"
Layout
2'-2"
1 5/8"2
3/4
"4
3/4
"2
5/8
"5 1
/8"
2 5
/8"
2'-
9"
6 3
/8"
R = 1/4" typical
Sign Type 110 - Vehicular Directional, Double Post
Typestyle: Frutiger 65 Bold
Colors: Sign Posts and Finials - Dark Gray Sign Panel and Frame - Dark Blue Text & Arrows - Reflective White Decorative Pattern - Medium Blue
Description: Double sided aluminum sign panel and post, painted with masked and sprayed decorative pattern and reflective vinyl text.
Scale: 3/4" = 1' - 0"
Elevation
Roll • Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 110.1Sign Type 110Vehicular Directional, Double Post
3'-5"
5'-
4"
3"
1'-
8"
7'-
3"
Decorative Pattern: masked and sprayed.
Sign Panel: painted aluminum
with reflective vinyl text.
Decorative Pattern: masked and sprayed
Removable aluminum trim cap
Sign Panel: painted aluminum
with reflective vinyl text
Sign Frame: painted aluminum channel
Custom cast aluminum finial, painted
Sign Post, 3" dia. aluminum, painted
Concrete footing as required.Concrete footing as required
Criteria: This sign is used for providing vehicular directions along campus roads and prior to the main campus entrance on Dana Avenue. Signs are to be located on University property prior to an intersection, as determined in the field and positioned on the right side of the travel lane. This sign type is intended for single sided use, but can be adapted for double sided use if necessary.
Cintas CenterParkingAB Cohen Center
AdmissionBellarmineChapel
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 110Vehicular Directional, Double Post
Date 110.2
Vertical Section
Half Scale
Horizontal Section
Half Scale
1"
1 1
/2"
1" x 1 1/2" x 1/8" aluminum channel sign frame, mitered corners, weld and grind smooth
1/8" thick aluminum header plate,weld to Sign Frame and grind smooth
45° bevel
Countersunk mechanical fastener
1" x 1" x 1/8" aluminum channel internal frame mitered corners, weld and grind smooth
Line of trim cap above
1/8" thick aluminum sign panel
1" x 1" x 1/8" aluminum channel internal frame with cross bracing as required, mitered corners, weld and grind smooth
Reveal: 1/8" x 1" aluminum, entire height of sign panel, continuous weld to post, painted to match post
3" diameter aluminum post
1 3/4"
Removable aluminum trim cap, mechanically fasten with countersunk fastenerpainted to match
1" x 1" x 1/8" aluminum channel internal frame mitered corners, weld and grind smooth
Sign Frame: 1" x 1 1/2" x 1/8" aluminum channel, mitered corners, weld and grind smooth
1/8" thick aluminum sign panel
1" x 1" x 1/8" aluminum cross bracing as required, weld to internal frameand grind smooth
1 1/2"
1"
3/8
"
Custom aluminum finial painted Dark Gray
Milled aluminum post cap
Headless set screw painted to match post
3" diameter aluminum post
Milled aluminum ring
affixed to post sleeve
5"
3/4
"3
/4"
1'-
3"
1/2" anchor plate and gussets
ss j bolts
Reinforced concrete footing
9"
3'-
6"
3 1/2" dia. aluminum post sleeve
Grade
Restore surface material to original
condition. See Technical Specifications
1 1/2" = 1’ - 0"
Post Cap, Base and Footing Detail
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 110Vehicular Directional, Double Post
Date 110.3
Roll Barresi & Associates
November 2011Date
4'-
6"
5'-
4"
Scale: 1" = 1' - 0"
Layout
Cintas CenterParkingAB Cohen Center
AdmissionBellarmineChapel
3'-5"
1"
1 5/8"
1 1/2" min.
margin
2 5
/16"
4 3
/4"
2"
3 1
/4"
6 1
/8"
1"
9"
5"
2 1
/4"
5"
4"
3/8
"
XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
110.4Sign Type 110Vehicular Directional, Double Post
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 111.1Sign Type 111 - Vehicular Directional, Single Post
Typestyle: Frutiger 65 Bold
Colors: Sign Post and Finial - Dark Gray Sign Panel and Frame- Dark Blue Text & Arrow - Reflective White Decorative Pattern - Medium Blue
Description: Double sided aluminum sign panel and post, painted with masked and sprayed decorative pattern and reflective vinyl text.
Criteria: This sign is used for providing vehicular directions along campus roads, particularly in the areas where landscaping, parked cars, and other obstructions along the edge of the road may restrict visibility to a double-posted sign type.
Signs are to be located on Campus prior to an intersection, as determined in the field. Positioned on the right hand side of the travel lane. This sign type is intended for single sided use, but can be adapted for double sided use if necessary.
Scale: 3/4" = 1' - 0"
Elevation
2'-9
"
2'-0"
Sign Type 111Vehicular Directional, Single Post
6"
7'-
0"
10'-
3"
Custom aluminum finial, painted
Sign Post, 3" dia. aluminum, painted
Concrete footing as required
Sign Panel:
painted aluminum
with reflective
vinyl text
Sign Frame:
painted aluminum
with removable bottom
Main EntranceCentral CampusBellarmineChapel
Decorative
Pattern: masked
and sprayed
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 111Vehicular Directional, Single Post
Date 111.2
Vertical Section
Half Scale
Horizontal Section
Half Scale
1"
1 1
/2"
1" x 1 1/2" x 1/8" aluminum channel sign frame, mitered corners, weld and grind smooth
1/8" thick aluminum header plate,weld to Sign Frame and grind smooth
45° bevel
Countersunk mechanical fastener
1" x 1" x 1/8" aluminum channel internal frame, mitered corners, weld and grind smooth
Line of trim cap above
1/8" thick aluminum sign panel
1" x 1" x 1/8" aluminum channel internal frame with cross bracing as required, mitered corners, weld and grind smooth
Reveal: 1/8" x 1" aluminum, entire height of sign panel, continuous weld to post, painted to match post
3" diameter aluminum post
1 3/4"
Aluminum trim cap, mechanically fasten with countersunk fastener painted to match
1" x 1" x 1/8" aluminum channel internal frame mitered corners, weld and grind smooth
Sign Frame: 1" x 1 1/2" x 1/8" aluminum channel, mitered corners, weld and grind smooth, with removable bottom
1/8" thick aluminum sign panel
1" x 1" x 1/8" aluminum cross bracing as required, weld to internal frameand grind smooth
1 1/2"
1"
3/8
"
Countersunk mechanical fastener
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 111Vehicular Directional, Single Post
Date 111.3
Custom aluminum finial painted Dark Gray
Milled aluminum post cap
Headless set screw painted to match post
3" diameter aluminum post
Milled aluminum ring
affixed to post sleeve
5"
3/4
"3
/4"
1'-
3"
1/2" anchor plate and gussets
ss j bolts
Reinforced concrete footing
9"
3'-
6"
3 1/2" dia. aluminum post sleeve
Grade
Restore surface material to original
condition. See Technical Specifications
1 1/2" = 1’ - 0"
Post Cap, Base and Footing Detail
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 111Vehicular Directional, Single Post
Date 111.4
Main EntranceCentral CampusBellarmineChapel
Scale: 1 1/2" = 1' - 0"
Layout
4 1
/8"
2 1
/8"
2"
typ
.4"
4"
3 1
/8"
2'-0"
1"
1 5/8"2'-
1/2
"
2'-
9"
1"
1 1/2" min.
margin
7 1
/2"
1 7
/8"
4 1
/4"
1"
3/8
"
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 112.1
EVENT ONLY5:00 PM
Scale: 3/4" = 1' - 0"
Elevation
3'-9
"
2'-5"
Sign Type 112Vehicular Directional, Temporary Events
Sign Type 112 - Vehicular Directional, Temporary Events
Typestyle: Frutiger 65 Bold
Artwork: Symbols to be provided.
Colors: Sign Frame - Black Sign Panel - Dark Blue Text & Arrow - Reflective White Symbols - As noted in layouts.
Description: Double sided sign with polycarbonate panel, painted with reflective vinyl graphics in Windmaster sign frame.
Criteria: This sign is used for providing vehicular directions in areas of campus during events, as neccessary, to control or divert the flow of traffic and manage parking. Signs are intended for single sided use but can be adapted for double-sided conditions. This is particularly true at the entrance to parking areas where vehicles will be approaching from two directions
Windmaster Classic Sign Frame
(Model #1005 by MDI Worldwide or equal)
Sign Panel: .020" polycarbonate, painted,
with reflective vinyl graphics
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 112Vehicular Directional, Temporary Events
Date 112.2
EVENT ONLY5:00 PM
2'-4"
3'-8
"
2 5/
8"1'
-3/4
"2"
5 5/
8"2
1/8"
4"6"
Scale: 1" = 1' - 0"
Layout 1
2 5/8" min.margin
2 5/8" min.margin
Parking Blue with Reflective
White outline and symbol
3 1/
2"
2 5/
16"
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 115.1Sign Type 115 - Parking ID, Large, Single Post
Typestyle: Bembo Semibold and Frutiger 65 Bold
Colors: Sign Post and Finial - Dark Gray Sign Panel and Frame - Dark Blue Text - Reflective White Decorative Pattern - Medium Blue
Description: Double sided aluminum sign panel and post, painted with masked and sprayed decorative pattern and reflective vinyl text.
Criteria: This sign is used for the identification of major Xavier University parking lots. The sign is most often to be located at the entrance to a parking lot and positioned perpendicular to the roadway.
Scale: 3/4" = 1' - 0"
Elevation
2'-0"
Sign Type 115Parking ID, Large, Single Post
VISITOR, FACULTYAND STAFF PARKING
PERMIT REQUIRED
GALLAGHERLOT
2'-
9"
6"
7'-
0"
10'-
3"
Custom aluminum finial, painted
Sign Post, 3" dia. aluminum, painted
Concrete footing as required
Decorative
Pattern: masked
and sprayed
Sign Panel:
painted aluminum
with reflective
vinyl text
Sign Frame:
painted aluminum
with removable bottom
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 115Parking ID, Large, Single Post
Date 115.2
Vertical Section
Half Scale
Horizontal Section
Half Scale
1"
1 1
/2"
1" x 1 1/2" x 1/8" aluminum channel sign frame, mitered corners, weld and grind smooth
1/8" thick aluminum header plate,weld to Sign Frame and grind smooth
45° bevel
Countersunk mechanical fastener
1" x 1" x 1/8" aluminum channel internal frame, mitered corners, weld and grind smooth
Line of trim cap above
1/8" thick aluminum sign panel
1" x 1" x 1/8" aluminum channel internal frame with cross bracing as required, mitered corners, weld and grind smooth
Reveal: 1/8" x 1" aluminum, entire height of sign panel, continuous weld to post, painted to match post
3" diameter aluminum post
1 3/4"
Aluminum trim cap, mechanically fasten with countersunk fastener painted to match
1" x 1" x 1/8" aluminum channel internal frame mitered corners, weld and grind smooth
Sign Frame: 1" x 1 1/2" x 1/8" aluminum channel, mitered corners, weld and grind smooth, with removable bottom
1/8" thick aluminum sign panel
1" x 1" x 1/8" aluminum cross bracing as required, weld to internal frameand grind smooth
1 1/2"
1"
3/8
"
Countersunk mechanical fastener
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 115Parking ID, Large, Single Post
Date 115.3
Custom aluminum finial painted Dark Gray
Milled aluminum post cap
Headless set screw painted to match post
3" diameter aluminum post
Milled aluminum ring
affixed to post sleeve
5"
3/4
"3
/4"
1'-
3"
1/2" anchor plate and gussets
ss j bolts
Reinforced concrete footing
9"
3'-
6"
3 1/2" dia. aluminum post sleeve
Grade
Restore surface material to original
condition. See Technical Specifications
1 1/2" = 1’ - 0"
Post Cap, Base and Footing Detail
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 115Parking ID, Large, Single Post
Date 115.4
VISITOR, FACULTYAND STAFF PARKING
PERMIT REQUIRED
GALLAGHERLOT
Scale: 1 1/2" = 1' - 0"
Layout 1
2'-0"
1"
1 5/8" min.margin
2'-
1/2
"
2'-
9"
1"
4"
2"
1 3
/4"
2"
4 1
/4"
1 1
/4"
2 1
/2"
5 3
/8"
1 5/8" min.margin
7 1
/2"
1 7
/8"
4 1
/4"
3/8
"
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 116.1Sign Type 116 - Parking ID, Small, Single Post
Typestyle: Bembo Semibold and Frutiger 65 Bold
Colors: Sign Post and Finial- Dark Gray Sign Panel - Dark Blue Text - Reflective White Decorative Pattern - Medium Blue
Description: Single sided aluminum sign panel and aluminum post, painted with masked and sprayed decorative pattern and reflective vinyl text.
Criteria: This sign is used for the identification of Xavier University parking lots that are small or staff only.
Signs are to be located on University property, parallel to the street, as determined in the field. This sign type is intended for single-sided use only.
Scale: 3/4" = 1' - 0"
Elevation
1'-1
0"
1'-4"
Sign Type 116Parking ID, Small, Single Post
STAFF PARKING
PERMIT REQUIRED
POWERPLANT
2"
5'-
0"
Custom aluminum finial, painted
Decorative Pattern, masked and sprayed
Sign Panel: Painted aluminum with reflective vinyl text
Sign Post: 2 1/2” diameter aluminum, painted
Concrete footing as required
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 116Parking ID, Small, Single Post
Date 116.22 1/2" diameter aluminum post
painted Dark Gray. Provide Post
Cap at top of post
Threaded rod stud welded to bracket and fastened to post
with acorn fastener. Fastener painted to match post
Aluminum channel the entire length of panel, welded to
back of panel and painted Dark Blue
1/8" aluminum sign panel mechanically fastened to
post with required hardware. Back of panel painted
Dark Blue
Half Size
Horizontal Section
1 1/2" = 1’ - 0"
Post Cap, Base and Footing Detail
Stainless Steel thru bolt
Gravel backfill
Reinforced Concrete
footing as required
9"
3'-
6"Galvanized steel post sleeve
with painted coating
Custom aluminum finial painted Dark Gray
Milled aluminum post cap
Headless set screw painted to match post
Restore surface material to original
condition. See Technical Specifications
5"
5/8
"5/8
"1'-
3"
Grade
2 1/2" diameter aluminum post
Milled aluminum ring
affixed to post sleeve
3" dia. aluminum post sleeve
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 116Parking ID, Small, Single Post
Date 116.3
STAFF PARKING
PERMIT REQUIRED
POWERPLANT
Scale: 1 1/2" = 1' - 0"
Layout 1
1'-4"
1'-
10"
1 1
/2"
2 1
/4"
2 1
/2"
3 1
3/1
6"
1"
7/8
"2 1
/4"
CL text on panel
1 1
/2"
2 3
/4"
R = 1/4" typical
1 1/2" min.
margin
1 1/2" min.
margin
C-1
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 117.1Sign Type 117 - Parking Lot Number Panel
Typestyle: Frutiger 65 Bold
Colors: Sign Panel - Dark Blue Text - Reflective White
Description: Single sided aluminum sign panel, painted with reflective vinyl text, mounted to extisting pole.
Criteria: This sign is used, in addition to Sign Type 15, to identify sections of Xavier University’s larger parking lots. It is to be placed where an existing light pole or utility pole is present.
2'-0"
Scale: 3/4" = 1' - 0"
Elevation
Sign Type 117Parking Lot Number Panel
2'-0
"12
'-6"
Ab
ove
finis
h gr
ade
Existing parking lot sign post
Sign Panel: painted aluminum
with reflective vinyl text
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 117Parking Lot Number Panel
Date 117.2
Half Size
Horizontal Section
3/4" Stainless Steel Strappingpaint strapping and bracket tomatch pole
Stainless Steel bracket to matchSignFix Bracket HPN177, two (2) per panel
1/8" thk. Alum. sign panel
SS threaded bolt and washer ptd.to match sign panel
Existing Round, square oroctagonal Utility Pole
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 117Parking Lot Number Panel
Date 117.3
EQ
EQ
8 1/
4"
2 1/8" min.margin
2 1/8" min.margin
Scale: 1 1/2" = 1' - 0"
Layout 1
2'-0" typical
2'-0
" ty
pic
al
C L text on panel
C-1
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 120.1Sign Type 120 - Campus Information Kiosk
Artwork: Map Artwork (1 side) provided on disc by Designer, Adobe Illustrator CS3
Poster Artwork (3 sides) provided by Owner
Colors: As Noted
Descritption: Fabricated aluminum kiosk with glass covered internally iluuminated poster cases (4 sides), pre-cast base and lead-coated copper roof.
Criteria: This four-sided kiosk is to be used for the display of promotional, event and wayfinding information. Kiosks should be located in central gateway areas and in close proximity to event facilities, such as the Cintas Center and Gallagher Hall, as well as an available power source.
Scale: 3/4" = 1' - 0"
Elevation
Sign Type 120 Campus Information Kiosk
1' -
3"
6' -
4"
1' -
3"
10"
9' -
8"
5' -
6"
(pos
ter
case
ove
rall)
5"E
Q3/
4" c
ham
fer
EQ
3' - 0"
2' - 6 1/2" (poster case overall)
Standing seam lead- or zinc-coated copper roofwith ball and spike finial
Frosted tempered glass with LED internal illumination
Fabricated aluminum sign structure painted Dark Gray
Glass covered poster case with LED internal illuminationMap Artwork (1 side)Owner Provided Poster (3 sides)
Poster: high resolution (600 dpi min.)digital transparency
Pre-cast stone base with chamfered top and eased vertical edges, color and finish to match Designer’s sample
Cast circle, 1/2” deep recess
Concrete footing as required
Electrical supply, rough-in by others,voltage to be coordinated
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 120 Campus Information Kiosk
Date 120.2
Scale: 3/4" = 1' - 0"
Roof Plan
Scale: 3/4" = 1' - 0"
Section at Poster Cabinet
3' - 0"
3' -
0"
EQ EQ EQ EQ
EQ
EQ
EQ
EQ
Note: Contractor to ensure that sign conforms with all applicable electrical code requirements.
Glass covered poster case(4 sides)
Line of roof overhang above
LED light fixtures on clearpolycarbonate carrier panelsNote: provide access to transformers
Transformers and shut off as required
Fabricated aluminum tube structure
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 120 Campus Information Kiosk
Date 120.3
Scale: 3" = 1' - 0"
Horizontal Section at Poster Cabinet
Scale: 3" = 1' - 0"
Horizontal Section at Frosted Glass Window Lights
3" x 3" x 1/4" alum tube
1/4" thick tempered glass
Spring steel clips or snap frame to hold poster
1/4" thick white polycarbonate diffuser panel Stainless steel cam lock
Line of base plate below
Line of pre-cast stonebase below
1/4" thick tempered glass,frosted first surface, white diffusing vinyl applied to second surface
1/2" x 1/2" x 1/8" alum channel
Continuous ss piano hinge
Weatherstrippingall around
3/8" alum
2" x 5/8" x 1/8" alum
1/2" x 1/8" alum,weld to channel andgrind smooth1 1/2" x 3" x 1/8" alum tube
2 1/2" x 2 1/2" x 1/2" alum angle
1/4" Reveal all around
Scale: 1 1/2" = 1' - 0"
Vertical Section
1/2" dia ss stud secured to base with epoxy as required
Pre-cast stone base
1" x 2" alum tube
1" x 2" alum tube
Frosted glass window lights
Glass covered poster case
LED light soruce (white) GE Tetra CL or equal on 1/4" thick clear polycarbonate carrier panel
Standing seam lead- or zinc-coatedcopper roof, wrap around bottom of plywood to prevent water infiltration
Notes: 1) All interior surfaces of sign cabinet painted White2) Contractor to ensure even illumination over enitre poster area
1" x 1" x 1/8" alum tube
1/2" thick alum base plate
2" x 2 1/2" x 1/8" alum
1/2" x 1 1/8" alum
1/2" dia ss studsecured to base and footing with epoxy as required
Finish gradeRestore surface material to original condition.See Technical Specifications
Scale: 1 1/2" = 1' - 0"
Vertical Section
Power supply, rough in by other(voltage to be confirmed)
Reinforced concretefooting as required
3"3'
- 9
" m
in.
3"
Plywood roof structure, 5/8" thick1" thick
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 120 Campus Information Kiosk
Date 120.4
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 121.1Sign Type 121 - Campus Map Display
Artwork: Map Artwork provided on disc by Designer, Adobe Illustrator CS3
Colors: As Noted
Description: Fabricated aluminum map display with digital high pressure laminate (dHPL) graphic panel, removable frame, waterjet-cut decorative grillwork, cast aluminum shield and pre-cast concrete base.
Criteria: This map display is used to provide pedestrian orientation information at Central Gathering areas, at decision points along pathways and at egress points from parking areas.
Displays should be oriented in the direction of the map graphic (facing North) whenever possible. If due North is not possible, West or East is acceptable. The map display must never be positioned facing South.
Scale: 3/4" = 1' - 0"
Front View
Scale: 3/4" = 1' - 0"
Graphic Panel
Scale: 3/4" = 1' - 0"
Side View
Sign Type 121Campus Map Display
4' - 9" (overall)
4' - 5" (frame opening)
2' -
3"
(ov
eral
l)
1' -
11"
(fr
ame
open
ing)
2' -
4"
1' -
4"
4"3"
3/4"
3/4"
1/2"
cha
mfe
r ed
ge
Fabricated aluminum framepainted Dark Blue
2 1/4" diameter aluminum tubepainted Dark Gray
1/4" thick waterjet-cut Decorative Pattern painted Silver
Cast aluminum shieldpainted 3 colors as noted
Pre-cast stone base, color and finish to match Designer’s sample
Concrete footing as required
Digital high pressure laimnate (dHPL) graphic panel
20°
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 121Campus Map Display
Date 121.2
Scale: 1 1/2" = 1' - 0"
Plan Section
2' - 8"EQ EQ
3' - 6"
8"E
QE
Q
1' -
4"
Scale: 3" = 1' - 0"
Section at Shield
Scale: 3" = 1' - 0"
Detail at Decorative Grillwork
3/4"
EQ
EQ
3"
3/4" 1/2"
1/2"1/2"
1/8"1/8"
1/2"
Alum. channel, plug weldto decorative grillwork and grind smooth
1/4" thick waterjet-cutdecorative grillwork
3/4" x 1/2" alum. vertical to capend of decorative grillwork
3/4" x 1/2" alum. cross brace
Alum. backer plate for shieldAlum shim weld and grind smoth3/8" thick cast alum shield painted 3 colors
6" (
shie
ld)
6 1/
2" (
back
er p
late
)
Line of framed geaphic panel above
2 1/4" dia. alum. post
1/2" x 3/4" alum. cross brace
1/2" x 3/4" alum.vertical
Alum. cover plate
Pre-cast stone base
Decorative grillwork
Cast alum shield
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 121Campus Map Display
Date 121.3
Scale: 1 1/2" = 1' - 0"
Base/Footing Detail
4' -
0"
4"2"
6"
2 1/4" diameter aluminum post
Stainless steel pin, set with adhesives as required
Concrete footing as required
Set alum tube post into pre-cast concrete basewith adhesives as required
Finish Grade
1/2" thick x 3 1/4" diameter aluminum cover plate,set with adhesives as required
R = 3/8"
1'-4"
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 121Campus Map Display
Date 121.4
2' - 3" (overall)
2' - 1" (graphic panel)
1 1/4" 3/4"
1' - 11" (frame opening)
2 1/2"
2"1"
Scale: 3" = 1' - 0"
Section at Graphic Panel
1/4" thick dHPL Graphic Panel with 1" alum. channel backer, bonded as required
Removable fabricated 1/8" thick alum frame with 45° bevel openings, corners mitered and ground smooth
Weatherproofing all around as required
1/4" thick alum. spacer, weld to backer plate, use to mechanically fasten graphic panel to backer plate as required
Alum. tube frame all around with mitered corners, weld and grind smooth to base plate, mechanically fasten to backer plate
1/4" thick alum. backer plate
1/4" thick alum. base plate, weld sign posts to base plate
Mechanically fasten frame to backer plate as required
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 123.1Sign Type 123 - Pedestrian Directional, Double Post
Typestyle: Bembo Semibold
Colors: Sign Post and Finial- Dark Gray Sign Panel and Frame- Dark Blue Text & Arrow - Reflective White Decorative Pattern - Medium Blue
Description: Double sided aluminum sign panel and aluminum posts, painted with masked and sprayed decorative pattern and reflective vinyl text.
Criteria: This sign is to be used for providing pedestrian directional information at major decision points where site lines are obstructed.
Typically, this is a double-sided sign meant to be read by pedestrians traveling in both directions along a path and should be positioned perpendicular to the path of travel to the right of the dominant direction of travel.
Scale: 3/4" = 1' - 0"
Elevation
1'-9"
3'-0
"
Sign Type 123 Pedestrian Directional, Double Post
Main CampusAdmission
Cintas CtrKuhlmanHusman
2"
1'-
10"
5'-
0"
Decorative Pattern: masked and sprayed
Removable aluminum trim cap
Sign Panel: painted aluminum
with reflective vinyl text
Sign Frame: painted aluminum channel
Custom aluminum finial, painted finish
Sign Post, 2 1/2" dia. aluminum, painted
Concrete footing as required
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 123 Pedestrian Directional, Double Post
Date 123.2
Vertical Section
Half Scale
1/8" thick aluminum header plate,weld to Sign Frame and grind smooth
45° bevel
Countersunk mechanical fastener
1" x 1" x 1/8" aluminum channel internal frame mitered corners, weld and grind smooth
1 3/4"
Removable aluminum trim cap, mechanically fasten with countersunk fastenerpainted to match
1" x 1" x 1/8" aluminum channel internal frame mitered corners, weld and grind smooth
Sign Frame: 1" x 1 1/2" x 1/8" aluminum channel, mitered corners, weld and grind smooth
1/8" thick aluminum sign panel
1" x 1" x 1/8" aluminum cross bracing as required, weld to internal frameand grind smooth
1 1/2"
1"
3/8
"
Horizontal Section
Half Scale
1"
1 1
/2"
1" x 1 1/2" x 1/8" aluminum channel sign frame, mitered corners, weld and grind smooth
Line of removable trim cap above
1/8" thick aluminum sign panel
1" x 1" x 1/8" aluminum channel internal frame with cross bracing as required, mitered corners, weld and grind smooth
Reveal: 1/8" x 1" aluminum, entire height of sign panel, continuous weld to post, painted to match post
2 1/2" diameter aluminum post
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 123 Pedestrian Directional, Double Post
Date 123.3
1 1/2" = 1’ - 0"
Post Cap, Base and Footing Detail
Cast aluminum finial painted Dark Gray
Milled aluminum post cap
Headless set screw painted to match post
Restore surface material to original
condition. See Technical Specifications
5"
5/8
"5
/8"
1'-
3"
1/2" anchor plate and gussets
ss j bolts
Reinforced concrete footing
9"
3'-
6"
Grade
2 1/2" diameter aluminum post
Milled aluminum ring
affixed to post sleeve
3" dia. aluminum post sleeve
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 123 Pedestrian Directional, Double Post
Date 123.4
Main CampusAdmission
Cintas CtrKuhlmanHusman
1"
2 3/
4"
1 1/
4"
1 9/
16"
3 1/
4"
Scale: 1 1/2" = 1' - 0"
Layout 1
1'-9" typical
C L Text on panel3'
-0"
typ
ical
2'-4
" ty
pic
al
1" min.margin
1" min.margin
1" typical 1" typical
1" t
ypic
al
2 1/
2"
7" t
yp.
1 5/
8"
3 3/
4"ty
p.
3/8"
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 124.1Sign Type 124 - Pedestrian Directional, Single Post
Typestyle: Bembo Semibold
Colors: Sign Post and Finial - Dark Gray Sign Panel - Dark Blue Text & Arrow - Reflective White Decorative Pattern - Medium Blue
Description: Single sided aluminum sign panel and aluminum post, painted with masked and sprayed decorative pattern and reflective vinyl text.
Criteria: This sign is to be used for providing pedestrian directional information along pathways where limited information.
Elevation
Sign Type 124 Pedestrian Directional, Single Post
WestCampus
AthleticFields
1'-4"
2'-
0"
2"
5'-
0"
Scale: 3/4" = 1' - 0"
Custom aluminum finial, painted
Decorative Pattern, masked and sprayed
Sign Panel: Painted aluminum with reflective vinyl text
Sign Post: 2 1/2” diameter aluminum, painted
Concrete footing as required
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 124 Pedestrian Directional, Single Post
Date 124.22 1/2" diameter aluminum post
painted Dark Gray. Provide Post
Cap at top of post
Threaded rod stud welded to bracket and fastened to post
with acorn fastener. Fastener painted to match post
Aluminum channel the entire length of panel, welded to
back of panel and painted Dark Blue
1/8" aluminum sign panel mechanically fastened to
post with required hardware. Back of panel painted
Dark Blue
Half Size
Horizontal Section
1 1/2" = 1’ - 0"
Post Cap, Base and Footing Detail
Stainless Steel thru bolt
Gravel backfill
Reinforced Concrete
footing as required
9"
3'-
6"Galvanized steel post sleeve
with painted coating
Custom aluminum finial painted Dark Gray
Milled aluminum post cap
Headless set screw painted to match post
Restore surface material to original
condition. See Technical Specifications
5"
5/8
"5/8
"1'-
3"
Grade
2 1/2" diameter aluminum post
Milled aluminum ring
affixed to post sleeve
3" dia. aluminum post sleeve
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 124 Pedestrian Directional, Single Post
Date 124.3
WestCampus
AthleticFields
2 5
/8"
2 5
/8"
1 5
/8"
1 3
/8"
2 9
/16"
Scale: 1 1/2" = 1' - 0"
Layout 1
C L Text on panel
1'-4" typical2'-
0"
typ
ical
1 1
/2"
2 3
/4"
1"
R = 1/4" typical
1 1/2" min.
margin
1 1/2" min.
margin
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 130.1Sign Type 130 - Freestanding Building ID, Large, Double Post
Typestyle: Bembo Semibold and Frutiger 55 Roman
Colors: Sign Posts and Finials - Dark Gray Sign Panel and Frame- Dark Blue Text - Reflective White Decorative Pattern - Medium Blue Shield - 3 Colors as noted in Graphic Standards
Description: Double sided aluminum sign panel and aluminum posts, painted with masked and sprayed decorative pattern and reflective vinyl text.
Criteria: This Sign is used for identifying major destinations along the campus perimeter or along streets with higher speed. Typically this sign should be installed perpendicular to the main road and is double-sided, unless otherwise noted.
Final locations are to be determined in the field.
Scale: 3/4" = 1' - 0"
Elevation
Sign Type 130Freestanding Building ID, Large, Double Post
ALUMNI CENTER
1 5 0 7 D A N A A V E N U E
6'-8"
3'-
0"
2"
1'-
10"
5'-
0"
Decorative Pattern:
masked and sprayed.
Sign Panel: painted aluminum
with reflective vinyl text.
Sign Frame: painted aluminum
Custom aluminum finial, painted
Sign Post, 3" dia. aluminum, painted
Removable aluminum
trim cap Cast aluminum
shield, painted
Concrete footing
as required
1/16"typ.
5/8"
8"
Scale: Half Full
Cast Aluminum Shield - Vertical Section
Scale: Half Full
Cast Aluminum Shield - Detail
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 130Freestanding Building ID, Large, Double Post
Date 130.2
Vertical Section
Half Scale
Horizontal Section
Half Scale
1"
1 1
/2"
1" x 1 1/2" x 1/8" aluminum channel sign frame, mitered corners, weld and grind smooth
1/8" thick aluminum header plate,weld to Sign Frame and grind smooth
45° bevel
Countersunk mechanical fastener
1" x 1" x 1/8" aluminum channel internal frame mitered corners, weld and grind smooth
Line of trim cap above
1/8" thick aluminum sign panel
1" x 1" x 1/8" aluminum channel internal frame with cross bracing as required, mitered corners, weld and grind smooth
Reveal: 1/8" x 1" aluminum, entire height of sign panel, continuous weld to post, painted to match post
3" diameter aluminum post
1 3/4"
Removable aluminum trim cap, mechanically fasten with countersunk fastenerpainted to match
1" x 1" x 1/8" aluminum channel internal frame mitered corners, weld and grind smooth
Sign Frame: 1" x 1 1/2" x 1/8" aluminum channel, mitered corners, weld and grind smooth
1/8" thick aluminum sign panel
1" x 1" x 1/8" aluminum cross bracing as required, weld to internal frameand grind smooth
1 1/2"
1"
3/8
"
Cast Shield bonded to face of header plate
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 130Freestanding Building ID, Large, Double Post
Date 130.3
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 130Freestanding Building ID, Large, Double Post
Date 130.4
Custom aluminum finial painted Dark Gray
Milled aluminum post cap
Headless set screw painted to match post
3" diameter aluminum post
Milled aluminum ring
affixed to post sleeve
5"
3/4
"3
/4"
1'-
3"
1/2" anchor plate and gussets
ss j bolts
Reinforced concrete footing
9"
3'-
6"
3 1/2" dia. aluminum post sleeve
Grade
Restore surface material to original
condition. See Technical Specifications
1 1/2" = 1’ - 0"
Post Cap, Base and Footing Detail
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 130Freestanding Building ID, Large, Double Post
Date 130.5
ALUMNI CENTER
1 5 0 7 D A N A A V E N U E
6"
4"
7"
2"
Scale: 3/4" = 1' - 0"
Layout 1 - Single Line
C L Text on panel
6'-8"
1"
3'-
0"
2'-
1"
10"
5"
4 1
/2"
7"
2"
3 5
/8"
4" min.
margin
4" min.
margin
1"
10
"
2 1
/2"
5"
8"
Sh
ield
1"
3/8
"
SCHOTT HALLADMISSIONS
1 5 0 7 D A N A A V E N U E
Scale: 3/4" = 1' - 0"
Layout 2 - Two Lines
Sign Type 131 - Freestanding Building ID, Large, Single Post
Typestyle: Bembo Semibold, Frutiger 55 Roman
Colors: Sign Post and Finial - Dark Gray Sign Panel and Frame - Dark Blue Text - Reflective White Decorative Pattern - Medium Blue Shield - 3 colors as noted in the Graphic Standards
Description: Double sided aluminum sign panel and aluminum posts, painted with masked and sprayed decorative pattern and reflective vinyl text.
Criteria: This sign is used for the identification of buildings where site lines may be obstructed by landscaping or parked cars.
Freestanding identification signs are typically used for buildings that have a significant first time visitor function or event component.
This sign is most often mounted perpendicular to the face of the building or pathway leading to the entry.
Scale: 3/4" = 1' - 0"
Elevation
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 131.1Sign Type 131Freestanding Building ID, Large, Single Post
GALLAGHERSTUDENTCENTER
2'-0"
2'-
9"
7'-
5/1
6"
6"
10'-
3"
Decorative Pattern:
masked and sprayed
Sign Panel: painted
aluminum with
reflective vinyl text.
Sign Frame: painted
aluminum with
removable bottom
Custom aluminum finial,
painted
Sign Post, 3" dia. aluminum, painted
Concrete footing as required
Cast aluminum
shield, painted
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 131Freestanding Building ID, Large, Single Post
Date 131.2
Scale: Half Full
Cast Aluminum Shield - Vertical Section
Scale: Half Full
Cast Aluminum Shield - Detail
5/8"
8" 1/16"typ.
Cast Shield bonded to face of header plate
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 131Freestanding Building ID, Large, Single Post
Date 131.3
Vertical Section
Half Scale
Horizontal Section
Half Scale
1"
1 1
/2"
1" x 1 1/2" x 1/8" aluminum channel sign frame, mitered corners, weld and grind smooth
1/8" thick aluminum header plate,weld to Sign Frame and grind smooth
45° bevel
Countersunk mechanical fastener
1" x 1" x 1/8" aluminum channel internal frame mitered corners, weld and grind smooth
Line of trim cap above
1/8" thick aluminum sign panel
1" x 1" x 1/8" aluminum channel internal frame with cross bracing as required, mitered corners, weld and grind smooth
Reveal: 1/8" x 1" aluminum, entire height of sign panel, continuous weld to post, painted to match post
3" diameter aluminum post
1 3/4"
Aluminum trim cap, mechanicallyfasten with countersunk fastenerpainted to match
1" x 1" x 1/8" aluminum channel internal frame mitered corners, weld and grind smooth
Sign Frame: 1" x 1 1/2" x 1/8" aluminum channel, mitered corners, weld and grind smooth withremovable bottom
1/8" thick aluminum sign panel
1" x 1" x 1/8" aluminum cross bracing as required, weld to internal frameand grind smooth
1 1/2"
1"
3/8
"
Custom aluminum finial painted Dark Gray
Milled aluminum post cap
Headless set screw painted to match post
3" diameter aluminum post
Milled aluminum ring
affixed to post sleeve
5"
3/4
"3
/4"
1'-
3"
1/2" anchor plate and gussets
ss j bolts
Reinforced concrete footing
9"
3'-
6"
3 1/2" dia. aluminum post sleeve
Grade
Restore surface material to original
condition. See Technical Specifications
1 1/2" = 1’ - 0"
Post Cap, Base and Footing Detail
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 131Freestanding Building ID, Large, Single Post
Date 131.4
GALLAGHERSTUDENTCENTER
2"
3 5
/8"
8 1
/4"
Scale: 1" = 1' - 0"
Layout 1
C L Text on panel
2'-0"
1"1 5/8" min.margin
1 5/8" min.margin
2'-
9"
2'-
3/8
"
1"
1"
7 1
/2"
4 1
/4"
8"
Sh
ield
1 7
/8"
3/8
"
Scale: 1" = 1' - 0"
Layout 2
Roll • Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 131Freestanding Building ID, Large, Single Post
Date 131.5
CONATONLEARNINGCOMMONS
1 0 0 1
F R A N C I S X A V I E R W A Y5
"2
"3 1
/2"
3 1
/2"
2 1
/4"
3 1
/4"
1"
C L Text on panel
Scale: 1" = 1' - 0"
Layout 3
HAYDENFIELD
5"
2"
2 3
/4"
4"
3 1
/2"
C L Text & Symbol
on panel
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 132.1Sign Type 132 - Freestanding Building ID, Large, Double Post
Typestyle: Bembo Semibold and Frutiger 55 Roman
Colors: Sign Posts and Finials - Dark Gray Sign Panel and Frame- Dark Blue Text - Reflective White Decorative Pattern - Medium Blue Shield - 3 Colors as noted in Grapic Standards
Description: Double sided aluminum sign panel and aluminum posts, painted with masked and sprayed decorative pattern and reflective vinyl text.
Scale: 3/4" = 1' - 0"
Elevation
Sign Type 132Freestanding Building ID, Small, Double Post
SMITH HALL
3'-8"
2'-
10 1
/2"
1'-
9"
4'-
9 1
/2"
Decorative Pattern: masked and sprayed
Removable aluminum trim cap
Sign Panel: painted aluminum
with reflective vinyl text
Sign Frame: painted aluminum
with removable top
Custom aluminum finial, painted
Sign Post, 3" dia. aluminum, painted
Concrete footing as required
Cast aluminum shield, painted
S T R E E T A D D R E S S
Criteria: There are two primary functions for this sign. The first is for the identification of buildings in areas of campus that are accessible primarily by pedes-trian paths and which have a significant student or first-time visitor function. The second is for secondary buildings along the perimeter or outlying areas of campus that do not serve a significant student or visitor population.
Signs should be mounted parallel to the face of the building and to one side of the entry or path.
These signs are primarily single sided but can be adapted for a double sided application if neces-sary, perpendicular to the path of travel.
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 132Freestanding Building ID, Small, Double Post
Date 132.2
Scale: Half Full
Cast Aluminum Shield - Vertical Section
Scale: Half Full
Cast Aluminum Shield - Detail
5/8"
8" 1/16"typ.
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 132Freestanding Building ID, Small, Double Post
Date 132.3
Vertical Section
Half Scale
Horizontal Section
Half Scale
1"
1 1
/2"
1" x 1 1/2" x 1/8" aluminum channel sign frame, mitered corners, weld and grind smooth
1/8" thick aluminum header plate,weld to Sign Frame and grind smooth
45° bevel
Countersunk mechanical fastener
1" x 1" x 1/8" aluminum channel internal frame mitered corners, weld and grind smooth
Line of trim cap above
1/8" thick aluminum sign panel
1" x 1" x 1/8" aluminum channel internal frame with cross bracing as required, mitered corners, weld and grind smooth
Reveal: 1/8" x 1" aluminum, entire height of sign panel, continuous weld to post, painted to match post
3" diameter aluminum post
1 3/4"
Removable aluminum trim cap, mechanically fasten with countersunk fastenerpainted to match
1" x 1" x 1/8" aluminum channel internal frame mitered corners, weld and grind smooth
Sign Frame: 1" x 1 1/2" x 1/8" aluminum channel, mitered corners, weld and grind smooth
1/8" thick aluminum sign panel
1" x 1" x 1/8" aluminum cross bracing as required, weld to internal frameand grind smooth
1 1/2"
1"
3/8
"
Cast Shield bonded to face of header plate
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 132Freestanding Building ID, Small, Double Post
Date 132.4
Custom aluminum finial painted Dark Gray
Milled aluminum post cap
Headless set screw painted to match post
3" diameter aluminum post
Milled aluminum ring
affixed to post sleeve
5"
3/4
"3
/4"
1'-
3"
1/2" anchor plate and gussets
ss j bolts
Reinforced concrete footing
9"
3'-
6"
3 1/2" dia. aluminum post sleeve
Grade
Restore surface material to original
condition. See Technical Specifications
1 1/2" = 1’ - 0"
Post Cap, Base and Footing Detail
Roll • Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 132Freestanding Building ID, Small, Double Post
Date 132.5
S T R E E T A D D R E S S
SMITH HALL
Scale: 1" = 1' - 0"
Layout 1 - Single Line
10
"5
3/4
"3"
EQ
EQ
5" 8"
Sh
ield
2 1
/2"
1 5
/8"
2'-
10 1
/2"
1"
3/8
"
C L Text on panel
1 5
/8"
Scale: 1" = 1' - 0"
Layout 2 - Two Lines
3 6 2 1 W O O D B U R N A V E N U E
CENTRALUTILITY PLANT
3 3
/4"
3"(
*)
EQ
5 1
/2"
EQ
(*) Note: Decrease text height
in 1/8" increments down from
3" when necessary for copy-
fitting purposes.
3'-8"
1"1" min.
margin1"
1" min.
margin
UNIVERSITYAPARTMENTS
3"(
*)
5 1
/2"
EQ
EQ
(*) Note: Decrease text height
in 1/8" increments down from
3" when necessary for copy-
fitting purposes.
Roll • Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 132Freestanding Building ID, Small, Double Post
Date 132.6
Scale: 1" = 1' - 0"
Layout 3 - No Address
3'-8"
1"1" min.
marginC L Text on panel1"
1" min.
margin
ARTGALLERY
Align
center of sign and wall
5'-0" VIF
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 133A.1Sign Type 133A - Building ID Plaque, Large
Typestyle: Bembo Semibold and Frutiger 55 Roman
Colors: Sign Panel and Frame- Dark Blue Text - White Decorative Pattern - Medium Blue Shield - 3 Colors as noted in Graphic Standards
Description: Single sided aluminum plaque, painted with masked and sprayed decorative pattern and white text, mounted to building by entrance.
Scale: 1/4" = 1' - 0"
Elevation 1
Sign Type 133ABuilding ID Plaque, Large
Criteria: Building plaques are to be used for identifying major buildings at secondary entrances, small scale academic buildings and residences, and separate entrances that service major destinations.
Signs are mounted to the building fascia adjacent to the entrance. The mounting height and position should adhere to the standards but may require adjustment based on field conditions and architec-tural features.
SCHOOLOF NURSING
4'-0" VIF
3'-
5"
VIF
1'-
7"
EQ
EQ
center of sign and wall
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 133ABuilding ID Plaque, Large
Date 133A.2
Scale: 1/4" = 1' - 0"
Elevation 2
3/16" thick aluminum plate Shield
bonded to face of header plate, ease edges
1/8" thick aluminum header plate,
weld to Sign Frame and grind smooth
45° bevel
3/4" x 1/2" x 1/8" aluminum channel internal
frame mitered corners, weld and grind smooth
Sign Frame: 3/4" x 1" x 1/8" aluminum channel,
mitered corners, weld and grind smooth with
removable top, ease edges
Sign Frame: 3/4" x 7/8" x 1/8"
aluminum angle removable top
1/8" thick aluminum sign panel, removable
1" x 1" x 1/8" aluminum cross bracing
as required, weld to internal frame
and grind smooth
Wall fasteners as required V.I.F
S.S. thread-ease tamperproof
fastener
1/4
"ty
p.
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 133ABuilding ID Plaque, Large
Date 133A.3
Scale: Half Size
Vertical Section
5 1
/2"
EQ
1 5
/8"
EQ
EQ
4 1
/4"
2 3
/8"
7/8
"
1'-
7"
3/4
"
1 6 2 6 H E R A L D A V E N U E
POWERPLANT
S T R E E T A D D R E S S
SINGLE LINE
ARTGALLERY
2'-0"
3/4"3/4" 3/4" min.margin
3/4" min.margin
C L
Graphics
on panel
7/8
"
EQ
1 5
/8"
2 7
/8"
EQ
EQ
EQ
1 5
/8"
3"
EQ
Decorative Pattern:
Sign Panel: painted aluminum
with masked and sprayed text
Sign Frame: painted aluminum
with removable top.
Decorative Pattern:
masked and sprayed
Sign Frame: painted aluminum
with removable top
Aluminum Plate shield,
masked and sprayed
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 133A.4Sign Type 133BBuilding ID Plaque, Small
Scale: 1 1/2" = 1' - 0"
Layout 1 - Single Line with Address
Scale: 1 1/2" = 1' - 0"
Layout 2 - Double Line with Address
Scale: 1 1/2" = 1' - 0"
Layout 3 - No Address
BUILDINGNAME
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 135A.1
CL
Sign Type 135A - Building ID Letters, Large
Typestyle: Bembo Regular
Color: Dark Gray Light Gray Description: 1" deep fabricated stainless steel letters with painted finish, stand-off pin mounted to building facade.
Criteria: Dimensional letters are used for identifying all building types and are mounted in the primary entrance side of the building, which may include more than one significant point of entry. If possible, the letters should be weighted closer to the building entrance to strengthen wayfinding.
The standard format for building identification letters is all caps. The size of the letters should be appropriate to the scale of the building and its prominence, as determined the field. Dimensional letters are used for identifying the building name only. Colleges, schools or departments shall not be identified on the exterior.
Scale: N.T.S.
Layout
Sign Type 135ABuilding ID Letters, Large
Stainless steel stand off
Stainless steel threaded stud set in epoxy
Letter height varies from 7 1/2" to 10"See Location Elevations for size.
Letter height shall be determinedin relation to the scale of the location.
Face of building
1" deep fabricated stainless steel letter, all edges and faces painted Dark Gray
1" 1/8"
Section
Scale: Half Size
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 135ABuilding ID Letters, Large
Date 135A.2
Location Elevation 1
Scale: 1/8” - 1’-0”
ELET H A LL8"
Align
Align
C L text and wall
Location Elevation 2
Scale: ±1/8” - 1’-0”
SCHOTT H A LL 8"
Align
Light Gray text
Light Gray text
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 135ABuilding ID Letters, Large
Date 135A.3
Location Elevation 3
Scale: 1/8” - 1’-0”
A. B. COH EN CEN TER Dark Gray text
3'-2
" V
IF
7'-2" VIF 8'-0" VIF 7'-2" VIF
5'-0" 6" 4'-7"
8"E
QE
Q
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 135B.1Sign Type 135BBuilding ID Letters, Medium
C L
Sign Type 135B - Building ID Letters, Medium
Typestyle: Bembo Regular
Color: Dark Gray Light Gray Description: 3/4" deep fabricated stainless steel letters with painted finish, stand-off pin mounted to building facade.
Criteria: Dimensional letters are used for identifying all building types and are mounted in the primary entrance side of the building, which may include more than one significant point of entry. If possible, the letters should be weighted closer to the building entrance to strengthen wayfinding.
The standard format for building identification letters is all caps. The size of the letters should be appropriate to the scale of the building and its prominence, as determined the field. Dimensional letters are used for identifying the building name only. Colleges, schools or departments shall not be identified on the exterior.
Scale: N.T.S.
Layout
MICHA EL J. CONATONLEARNING COMMONS
Letter height varies from 5" to 7"See Location Elevations for size
Letter height shall be determinedin relation to the scale of the location.
Stainless steel stand off
Stainless steel threaded stud set in epoxy
Face of building
3/4" deep fabricated stainless steel letter, all edges and faces painted Dark Gray
3/4"1/8"
Section
Scale: Half Size
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 135BBuilding ID Letters, Medium
Date 135B.2
M ICH A EL J. CONATONLE A R N ING COM MONS
M ICH A EL J. CONATONLE A R N ING COM MONS
M ICH A EL J. CONATONLE A R N ING COM MONS
M ICH A EL J. CONATONLE A R N ING COM MONS
NNNONATONONATONONATONONATONONATONONATONONATONCCCCCCCCCJJJJJJJJJJ CCL JJJJJJM ICH A ELICH A ELICH A ELICH A ELICH A ELICH A ELICH A ELMMMMMMMMMM NNNCONATONONATONONATONONATONONATONONATONONATONCCCCCCCCCCCCCCJJJJJJJJJJJJJM ICH A ELM ICH A ELM ICH A ELM ICH A ELM ICH A ELM ICH A ELM ICH A ELMMMMMMMMMM NNNNNNNNNNOOOOOOOOOOOOOOOOOOTTTTTTTAAAAAAANNNNNNNNNNNNNNNOOOOOOOOOOOOOOOOOOOOCOCCCCCCCCCCCCCCCCCCCCCCCCCJ..JJ......JJJJJJJ.............. CLLLLLL JJJJJELELELELELELA EA EA EA EA EA EH AH AH AH AH AH ACCCCCHCHCHCHCHCHCICM IM IM ICM IM IM IM IM IM IMMMMMMMMMMMMMMM
SSSLE A R N ING COM MONSE A R N ING COM MONSE A R N ING COM MONSE A R N ING COM MONSE A R N ING COM MONSE A R N ING COM MONSE A R N ING COM MONSLLLLLLLLLL SSSSLE A R N ING COM MONSLE A R N ING COM MONSLE A R N ING COM MONSLE A R N ING COM MONSLE A R N ING COM MONSLE A R N ING COM MONSLE A R N ING COM MONSLLLLL SSSSSSSSSSSNNNNNNNOOOONONONONONONONOOOMMMMMMM MM MM MM MM MM MOOMMMMMMOCOCOOOOCOOOOOOOCCCCCCCCCCCCCCGGGGGGGGGGGGGGGNGNNNGNNNNNNNNNNNNNNNNNNNNNNNNN
MMMMMMMMMMMMMMMMMMMMM
LLLLLLLLL
MMMM
LLLLLLLLLL
MMMMMMMMMMMMMM
EEEEEEEEE
MMMMMMMMMMMMMMMMMMMMMMM IIIIIIIIIIIIIIIIIIIIIIIIIIIIIII
AAAAAAAAAAAAAAAA
CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC
RRRRRRRRRRRRRRRRRRRRR
HHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHH
RRRRR
HHHHHHHHHHHHHHHHHHHHHHHHHHH
NNNNNNNNNNNN
AAAAAAAAAAAAAAAAAA
NNNNNNNNNNNNNNNNNNNNNNN
AAAAAAAAAAAAAAA
IIIIIIIIIIIIIIIIII
EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
EEEE
NNN
LLLLLLLLLLLLLLLLLLLLLL
GGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGG
JJJJJJJJJJJJJJJJJJJJJJJ
CCCCCCCCCCCCCCCCCCCCCC
CCCCCCCCCCCCCCCCCCCCCCCC
CCCCCCCCCCCCCCCCCCCCCCCCCC
CCCCCCCCCCCCCCCCCCC
OOOOOOOOOOOOOOOOOOOOOO
OOOOOOOOOOOOOOOOOOOOO
OOOOOOOOOOOOOOOOOOOOOOOOO
OOOOOOOOOOOOOOOOOOO
MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM
NNNNNNNNNNNNNNNN
MMMMMMMMMMMMMMMM
AAAAAAAAAAAAAAAAAAAAAA
MMMMMMMMMMMMMMMMMMMMMMMMMMMOOOOOOOOOOOOOOOOOOOOOOOOOOO
TTTTTTTTTT
OOOOOOOOOOOOOOOOOO
OOOOOOOOOOOOOOOOOOOO
NNNNNNNNNNNNNNNNNNNNNNNNNN
OOOOOOOOOOOOOOOOOOOOO
NNNNNNNNNNNNNNNN
NNNNNNNNNNNNNNNN
SSSSSSSSSSSSSSSSSSS
EQ EQEQ EQ
10'-0
"6"
1'-7
1/2
"
10'-0
"6"
1'-7
1/2
"
Location Elevation 1
Scale: 1/8” - 1’-0”
C L text and wall
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 135BBuilding ID Letters, Medium
Date 135B.3
SYCA MOR E HOUSE
Location Elevation 3
Scale: 1/8” - 1’-0”
ELET H A LL
C L
6"E
QE
Q
EQEQ
Light Gray text
6"
28"
VIF
EQ
EQ
C L text and wall
Location Elevation 2
Scale: 1/8” - 1’-0”
Light Gray text
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 135BBuilding ID Letters, Medium
Date 135B.4
Location Elevation 4
Scale: Not to scale
6"E
QE
Q
Location Elevation 5
Scale: 1/8” - 1’-0”
BISHOP EDWA R D FEN W ICK PLACE
C L
6"1'
-6"
Dark Gray textStandardLetterspacing
Dark Gray textStandardLetterspacing
EQ
EQ
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 135BBuilding ID Letters, Medium
Date 135B.5
Location Elevation 6
Scale: 1/8” - 1’-0”
BISHOP EDWA R D FEN W ICK PLACE
C L
6"E
QE
Q
A. B. COHEN CENTER
Location Elevation 7
Scale: 1/8” - 1’-0”
6 5/
8"2'
-8"
5'-8" VIF
9 1/2"
5'-8" VIF
4 1/2"Dark Gray text
Dark Gray textstandard letterspacing
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 135CBuilding ID Letters, Small
Date 135C.1Sign Type 135C - Building Letters, Small
Typestyle: Bembo Regular
Color: Dark Gray Description: 1/2" deep fabricated stainless steel letters with painted finish, stand-off pin mounted to building facade.
Criteria: Smaller dimensional letters are used to identify secondary buildings or augment the primary dimensional lettering when multiple entrances warrant additional letter sets.
Scale: N.T.S.
Layout
STEPHENAND DOLORES
SMITH HALL
CL
Letter height varies from 2 1/2" to 4 1/2"See Location Elevations for size
Letter height shall be determinedin relation to the scale of the location.
Section
Scale: Half Size
1/8"
1/2"
Stainless steel stand off
Stainless steel threaded stud set in epoxy
Face of building
1/2" deep fabricated stainless steel letter, all edges and faces painted Dark Gray
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 135CBuilding ID Letters, Small
Date 135C.2
Location Elevation 1
Scale: 3/8” - 1’-0”
STEPHEN AND DOLORES
SMITH HALL
STEPHEN AND DOLORES
SMITH HALLAlign
4"
EQEQ
8"8"
C L text and wall
Sign Type 138,see Dwg. No. 138.1
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 135CBuilding ID Letters, Small
Date 135C.3
Location Elevation 2
Scale: 3/8” - 1’-0”
BISHOP EDWARDFENWICK PLACE
3"6"
12"
C L text and wall
EQ EQ
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 136.1Sign Type 136 - Refurbish Letters
Description: Clean existing recessed masonry lettering and apply Translucent Gray Lithichrome Shadow to interior of letters.
Color: To match Designer’s Sample.
Criteria: Cleaning and applying a tint to existing carved lettering is done to improve legibility. This is particularly important for buildings with a high percentage of public or first-time visitors.
The application of Lithichrome Shadow should only be executed by an experienced crafts person, by hand, either with traditional brush or masked and airbrushed.
Sign Type 136Refurbish Letters
Scale: Not to Scale
Location Elevation 2
Scale: Not to Scale
Location Elevation 1
Clean and applyLithichrome Shadowto 10" recessedletters castin masonry.
Clean and applyLithichrome Shadowto 12" recessedletters castin masonry.
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 137.1Sign Type 137 - Building ID Letters on Panel
Typestyle: Bembo Regular
Color: Text - Dark Gray Background - TBD
Description: 3/4" deep fabricated metal letters with painted finish, mounted to panel.
Criteria: Sign panels with dimensional lettering shall be provided where building surfaces do not allow for the application of lettering directly on the building. Panels shall be scaled and positioned in a way that is consistent with the architecture and appropriate to existing patterns and linear relationships.
The color of the panels should complimentary to the architectural finishes.
Sign Type 137Building ID Letters on Panel
Scale: 3/8” - 1’-0”
Location Elevation 1
12'-0" VIF
3'-4
" V
IF SCHOTT HALLADMISSIONS
C L sign and fascia
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 137.2Sign Type 137Building ID Letters on Panel
1"
Section
Scale: Half Size
1/8" Alum. face andbracket, ptd. to matchDesigner’s Sample.
1" Alum. channel frame
3/4" deep fabricated metal letters, fastenedthrough face of sign, all edges and faces painted Dark Gray
Fastener
Mounting bracket,painted to matchsign panel
Existing iron barprovide shielding
Scale: 1/2” - 1’-0”
Layout 1
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 137.3Sign Type 137Building ID Letters on Panel
SCHOTT HALLADMISSIONS
EQ
8"E
Q9"
7"
3'-4
" V
IF
10'-9" VIF
C L text and panel
Sign Type 138 - Building Entrance Graphics
Typestyle: Bembo Regular
Color: Matte White Matte Black Red
Description: Vinyl applied to second surface of glass.
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 138.1
JOSEPH H A LL
Property of Xavier UniversityNo Trespassing
Caution: Automatic Door
Criteria: Building entrance graphics provide the name of the building directly at the entrance, along with additional information including trespass-ing message, automatic door message and the no smoking symbol.
The name of schools or colleges, depart-ments or other information is not permitted on entrance doors, with the following exceptions:
- Schools or Colleges associated with a donor name.
- If access to a specific department is only provided through one of many exterior doors, then the name of the department can be applied to that particular door.
Note: Letter sizes may have to be adjusted to fit on a panel. Use the letter sizes shown as a starting point. Adjust as necessary to fit existing conditions.
Scale: 1/2" = 1' - 0"
Condition 1 - Single Door
Graphics applied to secondsurface of glass panel.
NOTE: If glass has a tint that willreduce legibility significantly, applygraphics to first surface.
Sign Type 138Building Entrance Graphics
4'-9
"
Centerline doorand graphics
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 138Building Entrance Graphics
Date 138.2
JOSEPH H A LLJOSEPH H A LL
Property of Xavier UniversityNo Trespassing
Caution: Automatic Door
NA M E OF H A LL
Property of Xavier UniversityNo Trespassing
Caution: Automatic Door
NA M E OF H A LL
Property of Xavier UniversityNo Trespassing
Caution: Automatic Door
Scale: 3/8" = 1' - 0"
Condition 2 - One Pair of Double Doors
Scale: 3/8" = 1' - 0"
Condition 3 - Two Pairs of Double Doors
Apply building nameand No Smoking symbol
on lefthand leaf.
Apply all graphicson right hand leaf
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 138Building Entrance Graphics
Date 138.3
NA M E OF H A LL
Property of Xavier UniversityNo Trespassing
Caution: Automatic Door
NA M E OF H A LL
Property of Xavier UniversityNo Trespassing
Caution: Automatic Door
NA M E OF H A LL
Property of Xavier UniversityNo Trespassing
Caution: Automatic Door
Property of Xavier UniversityNo Trespassing
Caution: Automatic Door
Scale: 3/8" = 1' - 0"
Condition 4 - Center Light
Scale: 3/8" = 1' - 0"
Condition 5 - Sidelight
Scale: 3/8" = 1' - 0"
Condition 6 - Panelized Door
Apply building name on sidelight
Apply symbolsand other informationon door
Apply all information oncenter panel. Confirm dimensions
in field prior to fabrication.
Apply building name to center light.Apply symbols andother information ondoor panels as shown.
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 138Building Entrance Graphics
Date 138.4
JOSEPH HALL
Property of Xavier UniversityNo Trespassing
Caution: Automatic Door
1 3/
8"4
3/4"
4"4"
11/16"
1 1/
2"2"
1 1/
4"1
1/2"
CONATONLEARNINGCOMMONS
Property of Xavier UniversityNo Trespassing
Caution: Automatic Door
1 3/
8"
4’ - 9” A.F.F.2 11
/16"
2"
4"4"
11/16"
1 1/
2"2"
1 1/
4"1
1/2"
4’ - 9” A.F.F.
1 5/
16"
Scale: 1 1/2" = 1' - 0"
Layout - Single Line Name
Scale: 1 1/2" = 1' - 0"
Layout - Multiple Line Name
Matte White lettering.(Confirm in field. Provide
Matte Black letteringif lighting conditions require.)
Matte white outline andsymbol. Clear Background.
(See Above)
Red and Black symbol onMatte White background.
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 140.1Sign Type 140 - Regulatory
Typestyle: Frutiger 65 Bold
Colors: Sign Post - Dark Gray Sign Panel - Dark Blue Text & Arrow - Reflective White Accent Stripe - Medium Blue
Description: Single sided aluminum sign panel and aluminum post, painted with masked and sprayed stripe and reflective vinyl text.
Criteria: Small regulatory signs are used to provide campus policies and regulations. These signs are primarily located at the egress path from a parking area unless otherwise noted.
Regulatory signs are single-sided and mounted perpendicular to the path of travel.
Scale: 3/4" = 1' - 0"
Elevation
1'-3"
1'-
9"
FIREARMSPROHIBITED
EXCEPT BY AUTHORIZED
LAW ENFORCEMENT PERSONNEL
VIOLATORS ARE SUBJECT TO
PROSECUTION UNDER
SECTION 2911.21 ORC.
PUNISHALE BY A $250 FINE/
30 DAYS IN JAIL
5'-
0"
Sign Type 140Regulatory
Accent Stripe: masked and sprayed
Sign Panel: Painted aluminum with reflective vinyl text.
Sign Post: 2 1/2" diameter aluminum, painted.
Concrete footing as required
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 140Regulatory
Date 140.2
Stainless Steel thru bolt
Gravel backfill
Reinforced Concrete
footing as required
9"
3'-
6"
1 1/2" = 1’ - 0"
Footing Detail
Galvanized steel post sleeve
with painted coating
Restore surface material to original
condition. See Technical Specifications
Grade
2 1/2" diameter aluminum post
1/8" thick aluminum post cap,
weld and grind smooth,
painted to match post
2 1/2" diameter aluminum post
painted Dark Gray. Provide Post
Cap at top of post
Threaded rod stud welded to bracket and fastened to post
with acorn fastener. Fastener painted to match post
Aluminum channel the entire length of panel, welded to
back of panel and painted Dark Blue
1/8" aluminum sign panel mechanically fastened to
post with required hardware. Back of panel painted
Dark Blue
Half Size
Horizontal Section
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 140Regulatory
Date 140.3
1'-3"
1'-
9"
1 5/8" min.
margin
1 5/8" min.
margin
FIREARMSPROHIBITED
EXCEPT BY AUTHORIZED
LAW ENFORCEMENT PERSONNEL
VIOLATORS ARE SUBJECT TO
PROSECUTION UNDER
SECTION 2911.21 ORC.
PUNISHALE BY A $250 FINE/
30 DAYS IN JAIL
Scale: 1 1/2" = 1' - 0"
Layout 1
C L Text on panel
2 5
/8"
4 3
/8"
1"
4"
2 3
/16"
3"
1/2
"
1 1
/4"
2"
4 7
/8"
R = 1/4" typical
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 141.1Sign Type 141 - Parking Regulatory
Typestyle: Frutiger 65 Bold
Colors: Sign Post - Dark Gray Sign Panel - Dark Blue Text - Reflective White Symbols - As noted in layouts
Description: Single sided aluminum sign panel and aluminum post, painted with refelctive vinyl graphics and text.
Criteria: Parking regulatory signs are used for identifying and regulating the use of individual parking spaces or a designated area of parking.
Signs are single-sided. For reserved or accessible parking, provide a sign for each space.
Scale: 3/4" = 1' - 0"
Elevation
Sign Type 141Parking Regulatory
ACCESSIBLEPARKING
1'-0"
1'-
5"
5'-
0"
Sign Panel: Painted aluminum with reflective vinyl text.
Sign Post: 2 1/2" diameter aluminum, painted.
Concrete footing as required
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 141Parking Regulatory
Date 141.2
2 1/2" diameter aluminum post
painted Dark Gray. Provide Post
Cap at top of post
Threaded rod stud welded to bracket and fastened to post
with acorn fastener. Fastener painted to match post
Aluminum channel the entire length of panel, welded to
back of panel and painted Dark Blue
1/8" aluminum sign panel mechanically fastened to
post with required hardware. Back of panel painted
Dark Blue
Half Size
Horizontal Section
Stainless Steel thru bolt
Gravel backfill
Reinforced Concrete
footing as required
9"
3'-
6"
1 1/2" = 1’ - 0"
Footing Detail
Galvanized steel post sleeve
with painted coating
Restore surface material to original
condition. See Technical Specifications
Grade
2 1/2" diameter aluminum post
1/8" thick aluminum post cap,
weld and grind smooth,
painted to match post
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 141Parking Regulatory
Date 141.3
FIRELANE
VISITORPARKING
ACCESSIBLEPARKING
Scale: 1 1/2" = 1' - 0"
Layout 1
Scale: 1 1/2" = 1' - 0"
Layout 3
Scale: 1 1/2" = 1' - 0"
Layout 2
2 1
/2"
6"
2"
1 3
/16"
2"
1'-0"
6"
symbol
and arrow
EQ EQ
1'-
5"
typ
ical
C L text on panel
2"
7"
1 1
/2"
2 5
/8"
1 3
/16"
1 1
/8"
2"
6"
2 1
/2"
3/4
"
1 5
/8"
R = 1/4" typical
1" min.
margin
1" min.
margin
Parking Blue
with Reflective White
outline and graphic
Parking Blue
with Reflective White
outline and graphic
White circle with Red
outline / slash and Black ‘P’
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 142.1Sign Type 142 - Traffic Control
Typestyle: Bembo Semibold and Frutiger 65 Bold
Colors: Sign Post - Dark Gray Sign Panel - Dark Blue Text - Reflective White Accent stripe - Medium Blue
Description: Single sided aluminum sign panel and post, painted with masked and sprayed strip and refelctive vinyl graphics and text.
Criteria: Traffic control signs are used for regulating the movement of vehicular traffic in accordance with the Manual on Uniform Traffic Control signs and should be specified and located by a licensed Civil Engineer or Traffic Engineer.
Scale: 3/4" = 1' - 0"
Elevation
Sign Type 142Traffic Control
15MPH
1'-0"
1'-
5"
7’
0”
8'-
5"
Sign Panel: Painted
aluminum with
reflective vinyl text
Accent Stripe:
masked and sprayed
Sign Post: 3" diameter
aluminum, painted
Concrete footing as required
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 142Traffic Control
Date 142.2
3" diameter aluminum post
painted Dark Gray. Provide Post
Cap at top of post
Threaded rod stud welded to bracket and fastened to post
with acorn fastener. Fastener painted to match post
Aluminum channel the entire length of panel, welded to
back of panel and painted Dark Blue
1/8" aluminum sign panel mechanically fastened to
post with required hardware. Back of panel painted
Dark Blue
Half Size
Horizontal Section
Stainless Steel thru bolt
Gravel backfill
Reinforced Concrete
footing as required
9"
3'-
6"
1 1/2" = 1’ - 0"
Footing Detail
Galvanized steel post sleeve
with painted coating
Restore surface material to original
condition. See Technical Specifications
Grade
3" diameter aluminum post
1/8" thick aluminum post cap,
weld and grind smooth,
painted to match post
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 142Traffic Control
Date 142.3
15MPH
C L text on panel
Layouts 1
Scale: 1" = 1' - 0"
Note:Provide MUTCD Standard Sign Panels,paint back of panels Dark Gray
2'-0"
1'-6"
2'-0"
2'-0"
1'-4"
1'-1
0 3/
4"
2 3/
4"1/
2"
1 1/
2"
10"
1 5/
8"2"
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 142Traffic Control
Date 142.4
Layouts 2
Scale: 1" = 1' - 0"
Note:Provide MUTCD Standard Sign Panels,paint back of panels Dark Gray
2'-0"
2'-0"
2'-0"
3'-0"
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 143.1Sign Type 143 - Street Name Sign
Typestyle: Bembo Semibold
Colors: Sign Post and Finial - Dark Gray Sign Panel - Dark Blue Text - Reflective White
Description: Double sided aluminum sign panel and post, painted with refelctive vinyl text.
Note: Each location has two panels unless otherwise noted in the Message Schedule.
Criteria: This sign type is used for identifying streets that are within the University’s Campus and include the name of both the primary street and secondary intersecting street.
Scale: 3/4" = 1' - 0"
Elevation
Sign Type 143Street Name Sign
Varies, see layouts
10'-
3"
6"
Cast aluminum finial
painted Dark Gray
Aluminum sign post
and base painted
Dark Gray
Concrete footing as required
Victory PKWY
Text: reflective
sheeting
Aluminum sign panel
painted Dark Blue
7 3
/8"
Panel 2 at 90
degrees to panel 1
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 143Street Name
Date 143.2
Prim
ary
Road
Secondary Road
1/4" thick aluminum backer
panel painted Dark Gray
1/4" thick aluminum backer panel
set into and welded to post
painted Dark Gray
1/8" thick aluminum Sign Panel
both sides, painted Dark Blue
3/16" thick aluminum Plate both sides
bonded to backer panel, painted Dark Blue
Half Scale
Vertical Section through Sign Panel
3" dia. x 1/4" wall aluminum post
Half Scale
Horizontal Section
Plan View
7 3
/8"
1 3
/8"
6"
1/8" thick aluminum sign panel bonded to backer panel
Backer panel welded to post along entire length of seam.
Weld ground smooth and even.
1/4" Length of panel, varies - see layouts
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 143Street Name
Date 143.3
Cast aluminum finial painted Dark Gray
Milled aluminum post cap
Headless set screw painted to match post
3" diameter aluminum post
Milled aluminum ring
affixed to post sleeve
5"
3/4
"3
/4"
1'-
3"
1/2" anchor plate and gussets
ss j bolts
Reinforced concrete footing
9"
3'-
6"
3 1/2" dia. aluminum post sleeve
Grade
Restore surface material to original
condition. See Technical Specifications
1 1/2" = 1’ - 0"
Post Cap, Base and Footing Detail
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 143Street Name
Date 143.4
2'-6"
7 3
/8"
Scale: 1 1/2" = 1' - 0"
Layout 1
Scale: 1 1/2" = 1' - 0"
Layout 3
Herald AVE
1 3
/8"
6"
1 1
/2"
Align top of letters
7/8"
7/8"
2 3
/4" E
QE
Q
7 3
/8" 1 3
/8"
6"
2 3
/4" E
QE
Q
1 1/2" min.margin
1 1/2" min.margin
1 1/2" min.margin
1 1/2" min.margin
C L
C L
Francis Xavier WAY
3'-2"
2'-6"
7 3
/8"
Scale: 1 1/2" = 1' - 0"
Layout 2
Victory PKWY1 3
/8"
6"
1 3
/16"
2 3
/4"
1 1/2" min.margin
1 1/2" min.margin
C L
1 1
/2"
Align top of letters
1 1
/2"
Align top of letters
7/8"
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 144A.1Sign Type 144A - Accesible Path, Post and Panel
Colors: Sign Post - Dark Gray Sign Panel - Dark Blue Arrow - Reflective White Symbol - As noted in layouts
Description: Single sided aluminum sign panel and aluminum post, painted with refelctive vinyl graphics and text.
Scale: 3/4" = 1' - 0"
Elevation
Sign Type 144AAccesible Path Sign, Post & Panel
8"
11"
3'-
3"
Sign Panel: Painted aluminum
with reflective vinyl text
Sign Post: 2 1/2" diameter aluminum, painted
Concrete footing as required
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 144AAccesible Path Sign, Post & Panel
Date 144A.2
2 1/2" diameter aluminum post
painted Dark Gray. Provide Post
Cap at top of post
Threaded rod stud welded to bracket and fastened to post
with acorn fastener. Fastener painted to match post
Aluminum channel the entire length of panel, welded to
back of panel and painted Dark Blue
1/8" aluminum sign panel mechanically fastened to
post with required hardware. Back of panel painted
Dark Blue
Half Size
Horizontal Section
Stainless Steel thru bolt.
Shim as necessary to prevent rocking.
Gravel backfill
Reinforced Concrete
footing as required
9"
3'-
6"
1 1/2" = 1’ - 0"
Footing Detail
Galvanized steel post sleeve
with painted coating
Restore surface material to original
condition. See Technical Specifications
Grade
2 1/2" diameter aluminum post
1/8" thick aluminum post cap,
weld and grind smooth,
painted to match post
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 144AAccesible Path Sign, Post & Panel
Date 144A.3
8" typical
11"
typ
ical
C L Text on panel
Scale: 3" = 1' - 0"
Layout
Parking Blue
with Reflective White
outline and graphic
1 5
/8"
4"
1 1
/8"
2 1
/2"
R = 1/4" typical
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 144B.1Sign Type 144B - Accesible Path Sign, Wall Mounted
Colors: Sign Panel - Dark Blue Arrow - Reflective White Symbol - As noted in layouts
Description: Single sided aluminum sign panel, painted with refelctive vinyl graphics and text.
Scale: 3/4" = 1' - 0"
Elevation
Scale: 1 1/2" = 1' - 0"
Vertical Section
Sign Type 144BAccesible Path Sign, Wall Mounted
11"
Varies (fr
om
2'-
6"
to 5
'-0")
Existing wall surface, field verify material
1/8" Thick aluminum, painted with applied
vinyl graphics.
Stud mounted with adhesives as required
8"EQ EQ
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 144BAccesible Path, Wall Mounted
Date 144B.2
8" typical
11"
typ
ical
C L Text on panel
Scale: 3" = 1' - 0"
Layout
1 5
/8"
4"
1 1
/8"
2 1
/2"
R = 1/4" typical
Parking Blue
with Reflective White
outline and graphic
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 150.1Sign Type 150 - Vehicular Light Pole Banner
Artwork: To be provided by Owner.
Description: Double sided digital-print banner with banner brackets top and bottom, mounted to existing street light pole.
Scale: 1/4" = 1' - 0"
Elevation Scale: 3/4" = 1' - 0"
Mounting Detail
1'-9"
Sign Type 150Vehicular Light Pole Banner
8'-0
"12
'-0"
Existing street light pole
Full color digital print (600 dpi minimum)on exterior grade matte vinyl.Slip hems sewn top and bottom for banner brackets. Double stitch edges.
Banner bracket with polymer-coated fiberglass arms, attach to light polewith 3/4" stainless steel banding.
BannerFlex II hardware by Kalamazoo Banner Works or equal.
Provide tether to keep banner from slipping off post
Banner 3/4" stainless steel banding
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 151Pedestrian Light Pole Banner
Date 151.1Sign Type 151 - Pedestrian Light Pole Banner
Artwork: To be provided by Owner.
Description: Double sided digital-print banner mounted to existing bracket arms on existing pole.
Scale: 3/8" = 1' - 0"
Elevation
3'-8
"
VIF
1'-8"VIF
1'-8"VIF
Existing pedestrian light pole
Full color digital print (600 dpi minimum)on exterior grade matte vinyl.Slip hems sewn top and bottom for banner brackets. Double stitch edges.
Existing banner bracket arms
Concrete footing as required
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 152.1Sign Type 152Street Pole Banner
1'-9"
8'-0
"
21
' - 0
"
12
'-0"
Sign Type 152 - Street Pole Banner
Artwork: To be provided by Owner.
Colors: Banner - Full color, per artwork Pole and Bracket Arms - Black Ball Finial - Silver
Description: Double sided digital-print banner. Tapered aluminum banner pole with fabricated aluminum bracket arms.
Scale: 1/4" = 1' - 0"
Elevation
Full color digital print (600 dpi minimum)on exterior grade matte vinyl. Slip hems sewn top and bottom for banner brackets. Double stitch edges.
Tapered alum banner pole painted Blackas manufactured by:Pole TechEast Setauket, NY 800-633-6733or equal
Custom fabricated aluminum banner bracket arms painted Black
6" dia. aluminum ball finial painted Silver
2 1/2" 1' - 9" banner
8' -
0"
bann
er12
' - 0
" ab
ove
grad
e
1" closed alum adjustabletension arm (top only)
21' -
0"
expo
sed
3'-6" min.
6"
3'-6" min.
Split clamps with stainless steelbolts, color and finish to match pole
6" dia. aluminum ball finial
Tapered alum banner pole,diameter and wall thickness dimensions to be determined by pole manufacturer
2 set screws along bottom bracketarm to hold banner in place. Banners grommetted in set screwlocation.
Flash collar, finish to match polewith clear silicone caulk
Finish Grade, restore surface material to original condition. See Technical Specifications
2" waterproof cement
4 hardwood wedges, 90 degrees O.C.,tamped with clean dry sand
Reinforced concrete footing as required
16 GA corrugated galvanizedsteel sleeve, painted
18" sq. x 3/16" thick steel platewelded to sleeve
3 steel centering wedges 120 degrees O.C
3/4" dia. steel spike. Lengthto be verified by Contractor
Steel fins welded to steel pole120 degrees O.C. to prevent pole from rotating
2" dia. alum banner bracketarm, color and finish to match pole
18"
6"
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011Date 152.2Sign Type 152Street Pole Banner
1 1/
2"
3"
Fabricated aluminum cap
Scale: 3/4" = 1' - 0"
Fabrication Detail
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 153 Flag Pole Banner, Halyard
Date 153.1
Concrete footing as required
Access door
Tapered aluminum banner pole painted Blackas manufactured by:Pole TechEast Setauket, NY 800-633-6733or equal
Beaded retainermin. 3 required for banner, provide grommet in banner
Counter weight
3'-6"
16' -
0"
14' -
0"
EQ
E
Q
EQ
30' -
0"
Scale: 1/4" = 1' - 0"
Elevation
Sign Type 153 - Flag Pole Banner, Halyard
Artwork: To be provided by Owner
Colors: Banner - Full color, per artwork Pole - Black Ball Finial - Silver
Description: Double sided digital-print banner. Tapered aluminum banner pole with internal halyard.
Internal halyard truck
6" dia. alum ball finial painted Silver
Polyester applique banner (right readingboth sides with black-out layer in between),double stitch edges, with grommets to accept retainers.
Concrete footing as required
Scale: 1/4" = 1' - 0"
Elevation
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 154Flag Pole Banner, Fixed Bracket
Date 154.1Sign Type 154 - Flag Pole Banner, Fixed Bracket
Artwork: To be provided by Owner.
Colors: Banner - Full color, per artwork Pole - Black Ball Finial - Silver
Description: Double sided banner. Tapered aluminum banner pole with fabricated aluminum banner bracket arms.
3'-6"
16
' - 0
"1
4' -
0"
30
' - 0
"
Full color digital print (600 dpi minimum)on exterior grade matte vinyl or doublesided polyester applique banner withblack-out inner layer. Slip hems sewntop and bottom for banner brackets. Double stitch edges.
Tapered alum banner pole painted Black as manufactured by: Pole TechEast Setauket, NY 800-633-6733or equal
6" dia. aluminum ball finial painted Silver
Custom fabricated aluminum banner bracket arms painted Black
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 154Flag Pole Banner, Fixed Bracket
Date 154.2
3" 3' - 6" banner
16' -
0"
bann
er14
' - 0
" ab
ove
grad
e
1 1/2" closed alum adjustabletension arm (top only)
30' -
0"
expo
sed
3'-6" min.
6"
3'-6" min.
Split clamps with stainless steelbolts, color and finish to match pole
6" dia. aluminum ball finial
Flush aluminum pole cap
Tapered alum banner pole,diameter and wall thickness dimensions to be determined by pole manufacturer
2 set screws along bottom bracketarm to hold banner in place. Banners grommetted in set screwlocation.
Flash collar, finish to match polewith clear silicone caulk
Finish Grade, restore surface material to original condition. See Technical Specifications
2" waterproof cement
4 hardwood wedges, 90 degrees O.C.,tamped with clean dry sand
Reinforced concrete footing as required
16 GA corrugated galvanizedsteel sleeve, painted
18" sq. x 3/16" thick steel platewelded to sleeve
3 steel centering wedges 120 degrees O.C
3/4" dia. steel spike. Lengthto be verified by Contractor
Steel fins welded to steel pole120 degrees O.C. to prevent pole from rotating
2 1/2" dia. alum banner bracketarm, color and finish to match pole
18"
6"
3"
Scale: 3/4" = 1' - 0"
Fabrication Detail
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 155ABuilding Mounted Banner
Date 155A.1Sign Type 155A - Building Mounted Banner
Artwork: To be provided by Owner.
Colors: Banner - Full color, per artwork Bracket - Dark Gray
Description: Single sided digital-print banner. Fabricated steel bracket top and bottom.
Scale: 3/8" = 1' - 0"
Layout - Example
Ban
ner
Siz
e V
arie
s (
from
6 ft
. to
16 ft
.)S
ee L
ocat
ion
Ele
vatio
ns
2"2"
Banner Size Varies (from 3 ft. to 8 ft.)See Location Elevations
1" 1" 1" 1"
Full color digital print (600 dpi minimum)on exterior grade matte vinyl.Slip hems sewn top and bottom for banner brackets. Double stitch edges.
Fabricated steel bracket and base plate painted Dark Gray,mechanically fasten to buildingas required.
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 155Building Mounted Banner
Date 155A.2
Scale: 3" = 1' - 0"
Vetrical Section
3"
2" m
ax.
2" dia. steel pipe with capped ends
1/2" dia. stainless steel threaded rod
Banner
Building facade, field verifymaterial and mounting condition
1 1/2" dia. steel tube with capped ends
Mechanically fastenas required
12" x 12" x 1/2"steel base plate
Banner grommeted
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 155Building Mounted Banner
Date 155A.3
Scale: Not to Scale
Location Elevation - Example
± 10
'- 0"
Fie
ld V
erify
± 5'- 6" Field Verify
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 155BBuilding Mounted Banner, Vertical Strip
Date 155B.1Sign Type 155B - Building Mounted Banner, Vertical Strip
Artwork: To be provided by Owner.
Colors: Banner - Full color, per artwork Bracket - Dark Gray
Description: Single sided digital-print banner. Fabricated steel bracket top and bottom.
Scale: 3/8" = 1' - 0"
Layout - Example
Banner Size Varies (from 1 ft.-6 in. to 6 ft.)See Location Elevations
1" 1" 1" 1"
Ban
ner
Siz
e V
arie
s (
from
8 ft
. to
40
ft.)
See
Loc
atio
n E
leva
tions
2"2"
Full color digital print (600 dpi minimum)on exterior grade matte vinyl.Slip hems sewn top and bottom for banner brackets. Double stitch edges.
Fabricated steel bracket and base plate painted Dark Gray,mechanically fasten to buildingas required.
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 155BBuilding Mounted Banner, Vertical Strip
Date 155B.2
Scale: 3" = 1' - 0"
Vetrical Section
3"
2" m
ax.
2" dia. steel pipe with capped ends
1/2" dia. stainless steel threaded rod
Banner
Building facade, field verifymaterial and mounting condition
1 1/2" dia. steel tube with capped ends
Mechanically fastenas required
12" x 12" x 1/2"steel base plate
Banner grommeted
Roll Barresi & Associates XAVIER UNIVERSITY EXTERIOR SIGN STANDARDS
November 2011 Sign Type 155BBuilding Mounted Banner, Vertical Strip
Date 155B.3
Scale: Not to Scale
Location Elevation - Example
± 35
'- 0"
Fie
ld V
erify
± 2'- 9" Field Verify