© university of reading 2006. uk 20 april 2014 network infrastructure it supporters update – 26...
TRANSCRIPT
10 April 2023 © University of Reading 2006 www.reading.ac.uk
Network InfrastructureIT Supporters Update – 26 June 2007
2To put your footer here go to View > Header and Footer
Contents
• Network overview
• Server connectivity upgrade
• Wireless network changes
• Subnet changes
• DNS and DHCP infrastructure
3To put your footer here go to View > Header and Footer
Network overview
• Two separate networks– readingConnect (for halls of residence)– Campus network
• Both networks share common border area
• Focus on campus network– Each building connected at a minimum of 1Gbit/s– Except for Bulmershe and halls of residence
• New router to be installed at Bulmershe to make better use of existing switches and infrastructure
• Halls of residence too far away for more than 100Mbit/s
4To put your footer here go to View > Header and Footer
Network overview
• Border network forms connection between campus network, readingConnect and JANET
• Two JANET connections– Each 1Gbit/s over long-range fibre– Diverse routes– Endpoints over 1.5Km apart
• Fully resilient
• Traffic split across both links during normal operation– Campus traffic one way– readingConnect traffic goes the other
5To put your footer here go to View > Header and Footer
Network overview
• 10616 IP addresses in use by 8964 unique hosts
• 1844 hosts registered but not seen on network since Feb– These will be removed at the end of July– A list will be distributed to IT Supporters at start of July
• Monthly stats (2 hour average) show:– 92.81Mbit/s peak traffic flow from JANET to campus– Average flow of 27.17MBit/s inbound and 15.39MBits/
outbound– 95th percentile is 73.02Mbit/s
6To put your footer here go to View > Header and Footer
3804lpine
1
2
3
4
DIAG
STATUS
A
B
PSU CONSOLE MODEM MGMT
PCMCIALINK\ACTIVE
SMM45014
i
GM-4X45112
i
STATUS
1000 BASE-X
4321
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK
- DISABLED1 2 3 4
FM-32T45210
i
STATUS
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK
- DISABLED
10/100 BASE-TXMDI-X
4
20
1
17
8
24
5
21
12
28
9
25
16
32
13
29
1 2 3 4 5 6 7 8
10 11 12 13 14 15 16
18 19 20 21 22 23 24
26 27 28 29 30 31 32
17
25
9
FM-32T45210
i
STATUS
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK
- DISABLED
10/100 BASE-TXMDI-X
4
20
1
17
8
24
5
21
12
28
9
25
16
32
13
29
1 2 3 4 5 6 7 8
10 11 12 13 14 15 16
18 19 20 21 22 23 24
26 27 28 29 30 31 32
17
25
9
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
CONSOLE
49 50
MGM
T
PORT 49
PORT 50
Extreme Networks Summit48siR
1 2 3 4 A B 5 6 7 8
G60T61030
DS
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
G60T61030
DS
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
CONSOLE
MGMT
COMPACTFLASH
MSM-1XL60016
MS
TRE
NV
SY
S
ER
R
CONSOLE
MGMT
COMPACTFLASH
MSM-1XL60016
MS
TRE
NV
SY
S
ER
R
G60X61010
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
DS
G60X61010
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
DS
3804lpine
1
2
3
4
DIAG
STATUS
A
B
PSU CONSOLE MODEM MGMT
PCMCIALINK\ACTIVE
SMM45014
i
GM-4X45112
i
STATUS
1000 BASE-X
4321
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK
- DISABLED1 2 3 4
FM-32T45210
i
STATUS
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK
- DISABLED
10/100 BASE-TXMDI-X
4
20
1
17
8
24
5
21
12
28
9
25
16
32
13
29
1 2 3 4 5 6 7 8
10 11 12 13 14 15 16
18 19 20 21 22 23 24
26 27 28 29 30 31 32
17
25
9
FM-32T45210
i
STATUS
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK
- DISABLED
10/100 BASE-TXMDI-X
4
20
1
17
8
24
5
21
12
28
9
25
16
32
13
29
1 2 3 4 5 6 7 8
10 11 12 13 14 15 16
18 19 20 21 22 23 24
26 27 28 29 30 31 32
17
25
9
1 2 3 4 A B 5 6 7 8
CONSOLE
MGMT
COMPACTFLASH
MSM-1XL60016
MS
TRE
NV
SY
S
ER
R
CONSOLE
MGMT
COMPACTFLASH
MSM-1XL60016
MS
TRE
NV
SY
S
ER
R
G60T61030
DS
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
G60T61030
DS
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
G60X61010
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
DS
FWE-WK134.225.255.5
CORE-WK
DMZ-WK
SLB-WK
DIST-LYL
DIST-SSE DIST-LON
DIS
T-W
KH
3808lpine
1
2
3
4
5
6
7
8
PSU45012
SERVICE
DC ON
DC ON
WHEN INSTALLED IN 3808 THIS WAY UP
WHEN INSTALLED IN 3804 THIS WAY UP A
V Hz A100 - 120200 - 240
5060
136
613
6050
200 - 240100 - 120
Hz V
SLIDE TO REMOVE
PSU
PSU45012
SERVICE
DC ON
DC ON
WHEN INSTALLED IN 3808 THIS WAY UP
WHEN INSTALLED IN 3804 THIS WAY UP A
V Hz A100 - 120200 - 240
5060
136
613
6050
200 - 240100 - 120
Hz V
SLIDE TO REMOVE
PSU
DIAG
STATUS
A
B
PSU CONSOLE MODEM MGMT
PCMCIALINK\ACTIVE
SMM45014
i
GM-4X45112
i
STATUS
1000 BASE-X
4321
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK
- DISABLED1 2 3 4
GM-4X45112
i
STATUS
1000 BASE-X
4321
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK
- DISABLED1 2 3 4
GM-4X45112
i
STATUS
1000 BASE-X
4321
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK
- DISABLED1 2 3 4
FM-32T45210
i
STATUS
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK
- DISABLED
10/100 BASE-TXMDI-X
4
20
1
17
8
24
5
21
12
28
9
25
16
32
13
29
1 2 3 4 5 6 7 8
10 11 12 13 14 15 16
18 19 20 21 22 23 24
26 27 28 29 30 31 32
17
25
9
GM-4T45113
i
STATUS
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK
- DISABLED
100/1000 BASE-TX
1
MDI-X
2 3 4
1000 BASE-TX
1 2 3 4
1 2 3 4
GM-16X45121
31 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK
- DISABLED
1 2 3 4
5 6 7 8
9 10 11 12
13 14 15 16STATUS
1000 BASE-XSFP
GM-16T45122
31 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK
- DISABLED
1 2 3 4
5 6 7 8
9 10 11 12
13 14 15 16STATUS10/100/1000 BASE-T
GM-16T45122
31 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK
- DISABLED
1 2 3 4
5 6 7 8
9 10 11 12
13 14 15 16STATUS10/100/1000 BASE-T
3808lpine
1
2
3
4
5
6
7
8
PSU45012
SERVICE
DC ON
DC ON
WHEN INSTALLED IN 3808 THIS WAY UP
WHEN INSTALLED IN 3804 THIS WAY UP A
V Hz A100 - 120200 - 240
5060
136
613
6050
200 - 240100 - 120
Hz V
SLIDE TO REMOVE
PSU
PSU45012
SERVICE
DC ON
DC ON
WHEN INSTALLED IN 3808 THIS WAY UP
WHEN INSTALLED IN 3804 THIS WAY UP A
V Hz A100 - 120200 - 240
5060
136
613
6050
200 - 240100 - 120
Hz V
SLIDE TO REMOVE
PSU
DIAG
STATUS
A
B
PSU CONSOLE MODEM MGMT
PCMCIALINK\ACTIVE
SMM45014
i
GM-4X45112
i
STATUS
1000 BASE-X
4321
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK
- DISABLED1 2 3 4
GM-4X45112
i
STATUS
1000 BASE-X
4321
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK
- DISABLED1 2 3 4
GM-4X45112
i
STATUS
1000 BASE-X
4321
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK
- DISABLED1 2 3 4
GM-4X45112
i
STATUS
1000 BASE-X
4321
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK
- DISABLED1 2 3 4
GM-4X45112
i
STATUS
1000 BASE-X
4321
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK
- DISABLED1 2 3 4
FM-32T45210
i
STATUS
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK
- DISABLED
10/100 BASE-TXMDI-X
4
20
1
17
8
24
5
21
12
28
9
25
16
32
13
29
1 2 3 4 5 6 7 8
10 11 12 13 14 15 16
18 19 20 21 22 23 24
26 27 28 29 30 31 32
17
25
9
3808lpine
1
2
3
4
5
6
7
8
PSU45012
SERVICE
DC ON
DC ON
WHEN INSTALLED IN 3808 THIS WAY UP
WHEN INSTALLED IN 3804 THIS WAY UP A
V Hz A100 - 120200 - 240
5060
136
613
6050
200 - 240100 - 120
Hz V
SLIDE TO REMOVE
PSU
PSU45012
SERVICE
DC ON
DC ON
WHEN INSTALLED IN 3808 THIS WAY UP
WHEN INSTALLED IN 3804 THIS WAY UP A
V Hz A100 - 120200 - 240
5060
136
613
6050
200 - 240100 - 120
Hz V
SLIDE TO REMOVE
PSU
DIAG
STATUS
A
B
PSU CONSOLE MODEM MGMT
PCMCIALINK\ACTIVE
SMM45014
i
GM-4X45112
i
STATUS
1000 BASE-X
4321
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK
- DISABLED1 2 3 4
GM-4X45112
i
STATUS
1000 BASE-X
4321
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK
- DISABLED1 2 3 4
GM-16X45121
31 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK
- DISABLED
1 2 3 4
5 6 7 8
9 10 11 12
13 14 15 16STATUS
1000 BASE-XSFP
FWE-EG134.225.255.6
CORE-EG
DMZ-EG
SLB-EG
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
CONSOLE
49 50
MGM
T
PORT 49
PORT 50
Extreme Networks Summit48siR
1 2 3 4 A B 5 6 7 8
G60T61030
DS
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
G60T61030
DS
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
CONSOLE
MGMT
COMPACTFLASH
MSM-1XL60016
MS
TRE
NV
SY
S
ER
R
CONSOLE
MGMT
COMPACTFLASH
MSM-1XL60016
MS
TRE
NV
SY
S
ER
R
G60X61010
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
DS
G60X61010
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
DS
PCMCIA
CONSOLE
MODEM
STATUS
ALARM
PWR 2
TEMP
FW
SESSION
SHAPEPCMCIA
VPN
HA
FAN
PWR 1
UNTRUST
1
1 23 4
10/100 MGT HA-1 HA-2
TOP = LINK/ACTIVITYBOTTOM = 10/100 MbpsNETSCREEN 500
ISG 2000FE8
1 2 3 4 5 6 7 8
P W R ALARM TE M P S TATUS HA
FAN M O D1 M O D 2 M O D 3 FLAS H
COMPACT FLASHCONSOLE MODEM MGT
10/100
TX/RX LINK
1 3
2 4
N E T S C R E E N
I SG 2000 LOCK
UNLOCK
ISG 2000FE8
1 2 3 4 5 6 7 81
LINK
TX/RX
2
LINK
TX/RX
ISG 2000GB2
1
LINK
TX/RX
2
LINK
TX/RX
ISG 2000GB2
ISG 2000FE8
1 2 3 4 5 6 7 8
P W R ALARM TE M P S TATUS HA
FAN M O D1 M O D 2 M O D 3 FLAS H
COMPACT FLASHCONSOLE MODEM MGT
10/100
TX/RX LINK
1 3
2 4
N E T S C R E E N
I SG 2000 LOCK
UNLOCK
ISG 2000FE8
1 2 3 4 5 6 7 81
LINK
TX/RX
2
LINK
TX/RX
ISG 2000GB2
1
LINK
TX/RX
2
LINK
TX/RX
ISG 2000GB2
FWA-WK
FW-FMD
HA
FLASH
STATUS-1
SESSION
POWER
ALARM
CONSOL E MODEM COMPACT FLASH 1
10/100
TX/RX LINK2
10/100
TX/RX LINK3
10/100
TX/RX LINK4
10/100
TX/RX LINK
N e t S c r e e n – 5 0
7To put your footer here go to View > Header and Footer
Server connectivity upgrade
• Introduction of 10Gbit Ethernet into the core
• Two new (large) switches to be installed into ITS machine rooms– Each switch will have 10GBit/s to each core router (20Gbit/s)– Two switches connected to each other at 20Gbit/s– Each switch configured to connect up to 240 ports at 1Gbit/s– Switches configured as redundant pair for routing server
VLANs
• Two small switches will provide secondary connections– To be used by important systems only (Exchange, etc)
8To put your footer here go to View > Header and Footer
1 2 3 4 A B 5 6 7 8
CONSOLE
MGMT
COMPACTFLASH
MSM-1XL60016
MS
TR
EN
V
SY
S
ER
R
CONSOLE
MGMT
COMPACTFLASH
MSM-1XL60016
MS
TR
EN
V
SY
S
ER
R
10G6X61050
DS
1
2
3
4
5
6
1
2
3
4
5
6
G60X61010
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
DS
G60X61010
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
DS
G60T61030
DS
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
G60T61030
DS
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
1
2
3
4
7
8
9
10
6B
5A
Dia
gS
tat
G48T a 41515
2 51 2 62 2 73 2 84 2 95 3 06 3 17 3 28 2 39 3 41 0 3 51 1 3 61 2 3 71 3 3 81 4 3 91 5 4 01 6 4 11 7 4 21 8 4 31 9 4 42 0 4 52 1 4 62 2 4 72 3 4 82 4
ab
Dia
gS
tat
G48T a 41515
2 51 2 62 2 73 2 84 2 95 3 06 3 17 3 28 2 39 3 41 0 3 51 1 3 61 2 3 71 3 3 81 4 3 91 5 4 01 6 4 11 7 4 21 8 4 31 9 4 42 0 4 52 1 4 62 2 4 72 3 4 82 4
ab
Dia
gS
tat
G48T a 41515
2 51 2 62 2 73 2 84 2 95 3 06 3 17 3 28 2 39 3 41 0 3 51 1 3 61 2 3 71 3 3 81 4 3 91 5 4 01 6 4 11 7 4 21 8 4 31 9 4 42 0 4 52 1 4 62 2 4 72 3 4 82 4
ab
Dia
gS
tat
G48T a 41515
2 51 2 62 2 73 2 84 2 95 3 06 3 17 3 28 2 39 3 41 0 3 51 1 3 61 2 3 71 3 3 81 4 3 91 5 4 01 6 4 11 7 4 21 8 4 31 9 4 42 0 4 52 1 4 62 2 4 72 3 4 82 4
ab MSM-G8X 41211
ERR
ENV
1000BASE-X
1
5 8
4
MSTR/DIAG
SYS/STATCOMPACT FLASH
ACONSOLE
D RMGMT
4 83 72 61 5
MSM-G8X 41211
ERR
ENV
1000BASE-X
1
5 8
4
MSTR/DIAG
SYS/STATCOMPACT FLASH
ACONSOLE
D RMGMT
4 83 72 61 5
Dia
gS
tat
G48T a 41515
2 51 2 62 2 73 2 84 2 95 3 06 3 17 3 28 2 39 3 41 0 3 51 1 3 61 2 3 71 3 3 81 4 3 91 5 4 01 6 4 11 7 4 21 8 4 31 9 4 42 0 4 52 1 4 62 2 4 72 3 4 82 4
ab
Dia
gS
tat
10GBASE-X1 32 4
10G4X 41611
Dia
gS
tat
10GBASE-X1 32 4
10G4X 41611
1 2 3 4 A B 5 6 7 8
CONSOLE
MGMT
COMPACTFLASH
MSM-1XL60016
MS
TR
EN
V
SY
S
ER
R
CONSOLE
MGMT
COMPACTFLASH
MSM-1XL60016
MS
TR
EN
V
SY
S
ER
R
10G6X61050
DS
1
2
3
4
5
6
1
2
3
4
5
6
G60X61010
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
DS
G60X61010
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
DS
G60T61030
DS
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
G60T61030
DS
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
1
2
3
4
7
8
9
10
6B
5A
Dia
gS
tat
G48T a 41515
2 51 2 62 2 73 2 84 2 95 3 06 3 17 3 28 2 39 3 41 0 3 51 1 3 61 2 3 71 3 3 81 4 3 91 5 4 01 6 4 11 7 4 21 8 4 31 9 4 42 0 4 52 1 4 62 2 4 72 3 4 82 4
ab
Dia
gS
tat
G48T a 41515
2 51 2 62 2 73 2 84 2 95 3 06 3 17 3 28 2 39 3 41 0 3 51 1 3 61 2 3 71 3 3 81 4 3 91 5 4 01 6 4 11 7 4 21 8 4 31 9 4 42 0 4 52 1 4 62 2 4 72 3 4 82 4
ab
Dia
gS
tat
G48T a 41515
2 51 2 62 2 73 2 84 2 95 3 06 3 17 3 28 2 39 3 41 0 3 51 1 3 61 2 3 71 3 3 81 4 3 91 5 4 01 6 4 11 7 4 21 8 4 31 9 4 42 0 4 52 1 4 62 2 4 72 3 4 82 4
ab
Dia
gS
tat
G48T a 41515
2 51 2 62 2 73 2 84 2 95 3 06 3 17 3 28 2 39 3 41 0 3 51 1 3 61 2 3 71 3 3 81 4 3 91 5 4 01 6 4 11 7 4 21 8 4 31 9 4 42 0 4 52 1 4 62 2 4 72 3 4 82 4
ab MSM-G8X 41211
ERR
ENV
1000BASE-X
1
5 8
4
MSTR/DIAG
SYS/STATCOMPACT FLASH
ACONSOLE
D RMGMT
4 83 72 61 5
MSM-G8X 41211
ERR
ENV
1000BASE-X
1
5 8
4
MSTR/DIAG
SYS/STATCOMPACT FLASH
ACONSOLE
D RMGMT
4 83 72 61 5
Dia
gS
tat
G48T a 41515
2 51 2 62 2 73 2 84 2 95 3 06 3 17 3 28 2 39 3 41 0 3 51 1 3 61 2 3 71 3 3 81 4 3 91 5 4 01 6 4 11 7 4 21 8 4 31 9 4 42 0 4 52 1 4 62 2 4 72 3 4 82 4
ab
Dia
gS
tat
10GBASE-X1 32 4
10G4X 41611
Dia
gS
tat
10GBASE-X1 32 4
10G4X 41611
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
CONSOLE
49 50
MGM
T
PORT 49
PORT 50
Extreme Networks Summit48siR
3804lpine
1
2
3
4
DIAG
STATUS
A
B
PSU CONSOLE MODEM MGMT
PCMCIALINK\ACTIVE
SMM45014
i
GM-4X45112
i
STATUS
1000 BASE-X
4321
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK
- DISABLED1 2 3 4
GM-4X45112
i
STATUS
1000 BASE-X
4321
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK
- DISABLED1 2 3 4
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
CONSOLE
49 50
MGM
T
PORT 49
PORT 50
Extreme Networks Summit48siR
3804lpine
1
2
3
4
DIAG
STATUS
A
B
PSU CONSOLE MODEM MGMT
PCMCIALINK\ACTIVE
SMM45014
i
GM-4X45112
i
STATUS
1000 BASE-X
4321
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK
- DISABLED1 2 3 4
GM-4X45112
i
STATUS
1000 BASE-X
4321
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK
- DISABLED1 2 3 4
CONSOLE
FAN
PSU-i
PSU-E
Stack
MGMT
SolidBlinking Extreme Networks Summit 400-48t
R R
1 5
2 6
3 7
4 8
1x 2x 3x 4x 5 76 8 9 11 13 1510 12 14 161 32 4 25 27 29 3126 28 30 3217 19 21 2318 20 22 24 41 43 45 4742 44 46 4833 35 37 3934 36 38 40
Extreme NetworksSummit EPS-T
CONSOLE
FAN
PSU-i
PSU-E
Stack
MGMT
SolidBlinking Extreme Networks Summit 400-48t
R R
1 5
2 6
3 7
4 8
1x 2x 3x 4x 5 76 8 9 11 13 1510 12 14 161 32 4 25 27 29 3126 28 30 3217 19 21 2318 20 22 24 41 43 45 4742 44 46 4833 35 37 3934 36 38 40
Extreme NetworksSummit EPS-T
FWE-WK FWE-EG
DMZ-WK
SLB-WK SRV-WK SRV-EG
SRV-SEC-WK SRV-SEC-EG
SLB-WK
DMZ-EG
9To put your footer here go to View > Header and Footer
Server connectivity upgrade
10To put your footer here go to View > Header and Footer
Guest / wireless network changes
• Deployment of JANET Roaming / Eduroam– Web-based redirect no longer permitted to be
advertised as eduroam name– New wireless network across campus to sit alongside
existing service• SSID ‘eduroam’• Requires 802.1x and WPA / WPA2 encryption• Set up and forget – works everywhere that has
Eduroam
11To put your footer here go to View > Header and Footer
Guest / wireless network changes
• Changes to existing ‘rdg.ac.uk’ service– Will move outside firewall
• But retain protection from Internet hosts• Same set of base services as for JANET Roaming• Additional resilience through second BlueSocket device
– Web-based login will accept eduroam / JANET Roaming credentials
– Proposed service changes Summer 2008:• Users will no longer be able to sign on with plain
username– Must use ‘[email protected]’ instead
• Native CIFS access will be turned off – shares still accessible through NetDrive service (WebDAV gateway)
12To put your footer here go to View > Header and Footer
Guest / wireless network changes
• New IP address ranges:– 134.225.24.0 – 134.225.27.255 for JANET Roaming
service– 134.225.28.0 – 134.225.31.255 for plug-in and
‘rdg.ac.uk’ service
• Old address ranges to be removed by September 2007:– 134.225.8.0 – 134.225.15.255
13To put your footer here go to View > Header and Footer
Subnet changes
• Psychology to complete move to .114 subnet
• Soil and Plant Science to move to own subnets
• Systems Engineering to vacate .4 and .56 subnets
• Student subnets in Careers, Chaplaincy and RUSU to be separated
14To put your footer here go to View > Header and Footer
DNS / DHCP infrastructure
• Currently two central servers– Sun hardware– Open source software– A bunch of in-house scripts to generate DNS zones– More in-house scripts to generate DHCP configuration– Painful to manage– Relatively slow turn-around for IP address allocation
15To put your footer here go to View > Header and Footer
DNS / DHCP infrastructure
• New Infoblox 1550 appliances (HA pair)– Take over as master DNS database– Replace Sun boxes for DHCP– GUI for managing IP address and hostname allocation– Should give faster turn-around on IP allocations– Possibility of delegation (at least read-only) to IT
supporters
• Expansion of DNS topology– Existing Sun boxes become dedicated DNS cache servers– Addition of DNS servers into DMZ for best practise– Possible additional IT Services managed DNS secondary
server at off-site co-location facility