© university of reading 2006. uk 20 april 2014 network infrastructure it supporters update – 26...

15
18 May 2022 © University of Reading 2006 www.reading.ac. uk Network Infrastructure IT Supporters Update – 26 June 2007

Upload: grace-thomas

Post on 28-Mar-2015

216 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: © University of Reading 2006. uk 20 April 2014 Network Infrastructure IT Supporters Update – 26 June 2007

10 April 2023 © University of Reading 2006 www.reading.ac.uk

Network InfrastructureIT Supporters Update – 26 June 2007

Page 2: © University of Reading 2006. uk 20 April 2014 Network Infrastructure IT Supporters Update – 26 June 2007

2To put your footer here go to View > Header and Footer

Contents

• Network overview

• Server connectivity upgrade

• Wireless network changes

• Subnet changes

• DNS and DHCP infrastructure

Page 3: © University of Reading 2006. uk 20 April 2014 Network Infrastructure IT Supporters Update – 26 June 2007

3To put your footer here go to View > Header and Footer

Network overview

• Two separate networks– readingConnect (for halls of residence)– Campus network

• Both networks share common border area

• Focus on campus network– Each building connected at a minimum of 1Gbit/s– Except for Bulmershe and halls of residence

• New router to be installed at Bulmershe to make better use of existing switches and infrastructure

• Halls of residence too far away for more than 100Mbit/s

Page 4: © University of Reading 2006. uk 20 April 2014 Network Infrastructure IT Supporters Update – 26 June 2007

4To put your footer here go to View > Header and Footer

Network overview

• Border network forms connection between campus network, readingConnect and JANET

• Two JANET connections– Each 1Gbit/s over long-range fibre– Diverse routes– Endpoints over 1.5Km apart

• Fully resilient

• Traffic split across both links during normal operation– Campus traffic one way– readingConnect traffic goes the other

Page 5: © University of Reading 2006. uk 20 April 2014 Network Infrastructure IT Supporters Update – 26 June 2007

5To put your footer here go to View > Header and Footer

Network overview

• 10616 IP addresses in use by 8964 unique hosts

• 1844 hosts registered but not seen on network since Feb– These will be removed at the end of July– A list will be distributed to IT Supporters at start of July

• Monthly stats (2 hour average) show:– 92.81Mbit/s peak traffic flow from JANET to campus– Average flow of 27.17MBit/s inbound and 15.39MBits/

outbound– 95th percentile is 73.02Mbit/s

Page 6: © University of Reading 2006. uk 20 April 2014 Network Infrastructure IT Supporters Update – 26 June 2007

6To put your footer here go to View > Header and Footer

3804lpine

1

2

3

4

DIAG

STATUS

A

B

PSU CONSOLE MODEM MGMT

PCMCIALINK\ACTIVE

SMM45014

i

GM-4X45112

i

STATUS

1000 BASE-X

4321

GREEN

AMBER

FLASHING ORANGE

- ACTIVITY

- LINK OK

- DISABLED1 2 3 4

FM-32T45210

i

STATUS

GREEN

AMBER

FLASHING ORANGE

- ACTIVITY

- LINK OK

- DISABLED

10/100 BASE-TXMDI-X

4

20

1

17

8

24

5

21

12

28

9

25

16

32

13

29

1 2 3 4 5 6 7 8

10 11 12 13 14 15 16

18 19 20 21 22 23 24

26 27 28 29 30 31 32

17

25

9

FM-32T45210

i

STATUS

GREEN

AMBER

FLASHING ORANGE

- ACTIVITY

- LINK OK

- DISABLED

10/100 BASE-TXMDI-X

4

20

1

17

8

24

5

21

12

28

9

25

16

32

13

29

1 2 3 4 5 6 7 8

10 11 12 13 14 15 16

18 19 20 21 22 23 24

26 27 28 29 30 31 32

17

25

9

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48

CONSOLE

49 50

MGM

T

PORT 49

PORT 50

Extreme Networks Summit48siR

1 2 3 4 A B 5 6 7 8

G60T61030

DS

1

31

2

32

3

33

4

34

5

35

6

36

7

37

8

38

9

39

10

40

11

41

12

42

13

43

14

44

15

45

16

46

17

47

18

48

19

49

20

50

21

51

22

52

23

53

24

54

25

55

26

56

27

57

28

58

29

59

30

60

30 60

311

G60T61030

DS

1

31

2

32

3

33

4

34

5

35

6

36

7

37

8

38

9

39

10

40

11

41

12

42

13

43

14

44

15

45

16

46

17

47

18

48

19

49

20

50

21

51

22

52

23

53

24

54

25

55

26

56

27

57

28

58

29

59

30

60

30 60

311

CONSOLE

MGMT

COMPACTFLASH

MSM-1XL60016

MS

TRE

NV

SY

S

ER

R

CONSOLE

MGMT

COMPACTFLASH

MSM-1XL60016

MS

TRE

NV

SY

S

ER

R

G60X61010

1

31

2

32

3

33

4

34

5

35

6

36

7

37

8

38

9

39

10

40

11

41

12

42

13

43

14

44

15

45

16

46

17

47

18

48

19

49

20

50

21

51

22

52

23

53

24

54

25

55

26

56

27

57

28

58

29

59

30

60

30 60

311

DS

G60X61010

1

31

2

32

3

33

4

34

5

35

6

36

7

37

8

38

9

39

10

40

11

41

12

42

13

43

14

44

15

45

16

46

17

47

18

48

19

49

20

50

21

51

22

52

23

53

24

54

25

55

26

56

27

57

28

58

29

59

30

60

30 60

311

DS

3804lpine

1

2

3

4

DIAG

STATUS

A

B

PSU CONSOLE MODEM MGMT

PCMCIALINK\ACTIVE

SMM45014

i

GM-4X45112

i

STATUS

1000 BASE-X

4321

GREEN

AMBER

FLASHING ORANGE

- ACTIVITY

- LINK OK

- DISABLED1 2 3 4

FM-32T45210

i

STATUS

GREEN

AMBER

FLASHING ORANGE

- ACTIVITY

- LINK OK

- DISABLED

10/100 BASE-TXMDI-X

4

20

1

17

8

24

5

21

12

28

9

25

16

32

13

29

1 2 3 4 5 6 7 8

10 11 12 13 14 15 16

18 19 20 21 22 23 24

26 27 28 29 30 31 32

17

25

9

FM-32T45210

i

STATUS

GREEN

AMBER

FLASHING ORANGE

- ACTIVITY

- LINK OK

- DISABLED

10/100 BASE-TXMDI-X

4

20

1

17

8

24

5

21

12

28

9

25

16

32

13

29

1 2 3 4 5 6 7 8

10 11 12 13 14 15 16

18 19 20 21 22 23 24

26 27 28 29 30 31 32

17

25

9

1 2 3 4 A B 5 6 7 8

CONSOLE

MGMT

COMPACTFLASH

MSM-1XL60016

MS

TRE

NV

SY

S

ER

R

CONSOLE

MGMT

COMPACTFLASH

MSM-1XL60016

MS

TRE

NV

SY

S

ER

R

G60T61030

DS

1

31

2

32

3

33

4

34

5

35

6

36

7

37

8

38

9

39

10

40

11

41

12

42

13

43

14

44

15

45

16

46

17

47

18

48

19

49

20

50

21

51

22

52

23

53

24

54

25

55

26

56

27

57

28

58

29

59

30

60

30 60

311

G60T61030

DS

1

31

2

32

3

33

4

34

5

35

6

36

7

37

8

38

9

39

10

40

11

41

12

42

13

43

14

44

15

45

16

46

17

47

18

48

19

49

20

50

21

51

22

52

23

53

24

54

25

55

26

56

27

57

28

58

29

59

30

60

30 60

311

G60X61010

1

31

2

32

3

33

4

34

5

35

6

36

7

37

8

38

9

39

10

40

11

41

12

42

13

43

14

44

15

45

16

46

17

47

18

48

19

49

20

50

21

51

22

52

23

53

24

54

25

55

26

56

27

57

28

58

29

59

30

60

30 60

311

DS

FWE-WK134.225.255.5

CORE-WK

DMZ-WK

SLB-WK

DIST-LYL

DIST-SSE DIST-LON

DIS

T-W

KH

3808lpine

1

2

3

4

5

6

7

8

PSU45012

SERVICE

DC ON

DC ON

WHEN INSTALLED IN 3808 THIS WAY UP

WHEN INSTALLED IN 3804 THIS WAY UP A

V Hz A100 - 120200 - 240

5060

136

613

6050

200 - 240100 - 120

Hz V

SLIDE TO REMOVE

PSU

PSU45012

SERVICE

DC ON

DC ON

WHEN INSTALLED IN 3808 THIS WAY UP

WHEN INSTALLED IN 3804 THIS WAY UP A

V Hz A100 - 120200 - 240

5060

136

613

6050

200 - 240100 - 120

Hz V

SLIDE TO REMOVE

PSU

DIAG

STATUS

A

B

PSU CONSOLE MODEM MGMT

PCMCIALINK\ACTIVE

SMM45014

i

GM-4X45112

i

STATUS

1000 BASE-X

4321

GREEN

AMBER

FLASHING ORANGE

- ACTIVITY

- LINK OK

- DISABLED1 2 3 4

GM-4X45112

i

STATUS

1000 BASE-X

4321

GREEN

AMBER

FLASHING ORANGE

- ACTIVITY

- LINK OK

- DISABLED1 2 3 4

GM-4X45112

i

STATUS

1000 BASE-X

4321

GREEN

AMBER

FLASHING ORANGE

- ACTIVITY

- LINK OK

- DISABLED1 2 3 4

FM-32T45210

i

STATUS

GREEN

AMBER

FLASHING ORANGE

- ACTIVITY

- LINK OK

- DISABLED

10/100 BASE-TXMDI-X

4

20

1

17

8

24

5

21

12

28

9

25

16

32

13

29

1 2 3 4 5 6 7 8

10 11 12 13 14 15 16

18 19 20 21 22 23 24

26 27 28 29 30 31 32

17

25

9

GM-4T45113

i

STATUS

GREEN

AMBER

FLASHING ORANGE

- ACTIVITY

- LINK OK

- DISABLED

100/1000 BASE-TX

1

MDI-X

2 3 4

1000 BASE-TX

1 2 3 4

1 2 3 4

GM-16X45121

31 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

GREEN

AMBER

FLASHING ORANGE

- ACTIVITY

- LINK OK

- DISABLED

1 2 3 4

5 6 7 8

9 10 11 12

13 14 15 16STATUS

1000 BASE-XSFP

GM-16T45122

31 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

GREEN

AMBER

FLASHING ORANGE

- ACTIVITY

- LINK OK

- DISABLED

1 2 3 4

5 6 7 8

9 10 11 12

13 14 15 16STATUS10/100/1000 BASE-T

GM-16T45122

31 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

GREEN

AMBER

FLASHING ORANGE

- ACTIVITY

- LINK OK

- DISABLED

1 2 3 4

5 6 7 8

9 10 11 12

13 14 15 16STATUS10/100/1000 BASE-T

3808lpine

1

2

3

4

5

6

7

8

PSU45012

SERVICE

DC ON

DC ON

WHEN INSTALLED IN 3808 THIS WAY UP

WHEN INSTALLED IN 3804 THIS WAY UP A

V Hz A100 - 120200 - 240

5060

136

613

6050

200 - 240100 - 120

Hz V

SLIDE TO REMOVE

PSU

PSU45012

SERVICE

DC ON

DC ON

WHEN INSTALLED IN 3808 THIS WAY UP

WHEN INSTALLED IN 3804 THIS WAY UP A

V Hz A100 - 120200 - 240

5060

136

613

6050

200 - 240100 - 120

Hz V

SLIDE TO REMOVE

PSU

DIAG

STATUS

A

B

PSU CONSOLE MODEM MGMT

PCMCIALINK\ACTIVE

SMM45014

i

GM-4X45112

i

STATUS

1000 BASE-X

4321

GREEN

AMBER

FLASHING ORANGE

- ACTIVITY

- LINK OK

- DISABLED1 2 3 4

GM-4X45112

i

STATUS

1000 BASE-X

4321

GREEN

AMBER

FLASHING ORANGE

- ACTIVITY

- LINK OK

- DISABLED1 2 3 4

GM-4X45112

i

STATUS

1000 BASE-X

4321

GREEN

AMBER

FLASHING ORANGE

- ACTIVITY

- LINK OK

- DISABLED1 2 3 4

GM-4X45112

i

STATUS

1000 BASE-X

4321

GREEN

AMBER

FLASHING ORANGE

- ACTIVITY

- LINK OK

- DISABLED1 2 3 4

GM-4X45112

i

STATUS

1000 BASE-X

4321

GREEN

AMBER

FLASHING ORANGE

- ACTIVITY

- LINK OK

- DISABLED1 2 3 4

FM-32T45210

i

STATUS

GREEN

AMBER

FLASHING ORANGE

- ACTIVITY

- LINK OK

- DISABLED

10/100 BASE-TXMDI-X

4

20

1

17

8

24

5

21

12

28

9

25

16

32

13

29

1 2 3 4 5 6 7 8

10 11 12 13 14 15 16

18 19 20 21 22 23 24

26 27 28 29 30 31 32

17

25

9

3808lpine

1

2

3

4

5

6

7

8

PSU45012

SERVICE

DC ON

DC ON

WHEN INSTALLED IN 3808 THIS WAY UP

WHEN INSTALLED IN 3804 THIS WAY UP A

V Hz A100 - 120200 - 240

5060

136

613

6050

200 - 240100 - 120

Hz V

SLIDE TO REMOVE

PSU

PSU45012

SERVICE

DC ON

DC ON

WHEN INSTALLED IN 3808 THIS WAY UP

WHEN INSTALLED IN 3804 THIS WAY UP A

V Hz A100 - 120200 - 240

5060

136

613

6050

200 - 240100 - 120

Hz V

SLIDE TO REMOVE

PSU

DIAG

STATUS

A

B

PSU CONSOLE MODEM MGMT

PCMCIALINK\ACTIVE

SMM45014

i

GM-4X45112

i

STATUS

1000 BASE-X

4321

GREEN

AMBER

FLASHING ORANGE

- ACTIVITY

- LINK OK

- DISABLED1 2 3 4

GM-4X45112

i

STATUS

1000 BASE-X

4321

GREEN

AMBER

FLASHING ORANGE

- ACTIVITY

- LINK OK

- DISABLED1 2 3 4

GM-16X45121

31 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

GREEN

AMBER

FLASHING ORANGE

- ACTIVITY

- LINK OK

- DISABLED

1 2 3 4

5 6 7 8

9 10 11 12

13 14 15 16STATUS

1000 BASE-XSFP

FWE-EG134.225.255.6

CORE-EG

DMZ-EG

SLB-EG

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48

CONSOLE

49 50

MGM

T

PORT 49

PORT 50

Extreme Networks Summit48siR

1 2 3 4 A B 5 6 7 8

G60T61030

DS

1

31

2

32

3

33

4

34

5

35

6

36

7

37

8

38

9

39

10

40

11

41

12

42

13

43

14

44

15

45

16

46

17

47

18

48

19

49

20

50

21

51

22

52

23

53

24

54

25

55

26

56

27

57

28

58

29

59

30

60

30 60

311

G60T61030

DS

1

31

2

32

3

33

4

34

5

35

6

36

7

37

8

38

9

39

10

40

11

41

12

42

13

43

14

44

15

45

16

46

17

47

18

48

19

49

20

50

21

51

22

52

23

53

24

54

25

55

26

56

27

57

28

58

29

59

30

60

30 60

311

CONSOLE

MGMT

COMPACTFLASH

MSM-1XL60016

MS

TRE

NV

SY

S

ER

R

CONSOLE

MGMT

COMPACTFLASH

MSM-1XL60016

MS

TRE

NV

SY

S

ER

R

G60X61010

1

31

2

32

3

33

4

34

5

35

6

36

7

37

8

38

9

39

10

40

11

41

12

42

13

43

14

44

15

45

16

46

17

47

18

48

19

49

20

50

21

51

22

52

23

53

24

54

25

55

26

56

27

57

28

58

29

59

30

60

30 60

311

DS

G60X61010

1

31

2

32

3

33

4

34

5

35

6

36

7

37

8

38

9

39

10

40

11

41

12

42

13

43

14

44

15

45

16

46

17

47

18

48

19

49

20

50

21

51

22

52

23

53

24

54

25

55

26

56

27

57

28

58

29

59

30

60

30 60

311

DS

PCMCIA

CONSOLE

MODEM

STATUS

ALARM

PWR 2

TEMP

FW

SESSION

SHAPEPCMCIA

VPN

HA

FAN

PWR 1

UNTRUST

1

1 23 4

10/100 MGT HA-1 HA-2

TOP = LINK/ACTIVITYBOTTOM = 10/100 MbpsNETSCREEN 500

ISG 2000FE8

1 2 3 4 5 6 7 8

P W R ALARM TE M P S TATUS HA

FAN M O D1 M O D 2 M O D 3 FLAS H

COMPACT FLASHCONSOLE MODEM MGT

10/100

TX/RX LINK

1 3

2 4

N E T S C R E E N

I SG 2000 LOCK

UNLOCK

ISG 2000FE8

1 2 3 4 5 6 7 81

LINK

TX/RX

2

LINK

TX/RX

ISG 2000GB2

1

LINK

TX/RX

2

LINK

TX/RX

ISG 2000GB2

ISG 2000FE8

1 2 3 4 5 6 7 8

P W R ALARM TE M P S TATUS HA

FAN M O D1 M O D 2 M O D 3 FLAS H

COMPACT FLASHCONSOLE MODEM MGT

10/100

TX/RX LINK

1 3

2 4

N E T S C R E E N

I SG 2000 LOCK

UNLOCK

ISG 2000FE8

1 2 3 4 5 6 7 81

LINK

TX/RX

2

LINK

TX/RX

ISG 2000GB2

1

LINK

TX/RX

2

LINK

TX/RX

ISG 2000GB2

FWA-WK

FW-FMD

HA

FLASH

STATUS-1

SESSION

POWER

ALARM

CONSOL E MODEM COMPACT FLASH 1

10/100

TX/RX LINK2

10/100

TX/RX LINK3

10/100

TX/RX LINK4

10/100

TX/RX LINK

N e t S c r e e n – 5 0

Page 7: © University of Reading 2006. uk 20 April 2014 Network Infrastructure IT Supporters Update – 26 June 2007

7To put your footer here go to View > Header and Footer

Server connectivity upgrade

• Introduction of 10Gbit Ethernet into the core

• Two new (large) switches to be installed into ITS machine rooms– Each switch will have 10GBit/s to each core router (20Gbit/s)– Two switches connected to each other at 20Gbit/s– Each switch configured to connect up to 240 ports at 1Gbit/s– Switches configured as redundant pair for routing server

VLANs

• Two small switches will provide secondary connections– To be used by important systems only (Exchange, etc)

Page 8: © University of Reading 2006. uk 20 April 2014 Network Infrastructure IT Supporters Update – 26 June 2007

8To put your footer here go to View > Header and Footer

1 2 3 4 A B 5 6 7 8

CONSOLE

MGMT

COMPACTFLASH

MSM-1XL60016

MS

TR

EN

V

SY

S

ER

R

CONSOLE

MGMT

COMPACTFLASH

MSM-1XL60016

MS

TR

EN

V

SY

S

ER

R

10G6X61050

DS

1

2

3

4

5

6

1

2

3

4

5

6

G60X61010

1

31

2

32

3

33

4

34

5

35

6

36

7

37

8

38

9

39

10

40

11

41

12

42

13

43

14

44

15

45

16

46

17

47

18

48

19

49

20

50

21

51

22

52

23

53

24

54

25

55

26

56

27

57

28

58

29

59

30

60

30 60

311

DS

G60X61010

1

31

2

32

3

33

4

34

5

35

6

36

7

37

8

38

9

39

10

40

11

41

12

42

13

43

14

44

15

45

16

46

17

47

18

48

19

49

20

50

21

51

22

52

23

53

24

54

25

55

26

56

27

57

28

58

29

59

30

60

30 60

311

DS

G60T61030

DS

1

31

2

32

3

33

4

34

5

35

6

36

7

37

8

38

9

39

10

40

11

41

12

42

13

43

14

44

15

45

16

46

17

47

18

48

19

49

20

50

21

51

22

52

23

53

24

54

25

55

26

56

27

57

28

58

29

59

30

60

30 60

311

G60T61030

DS

1

31

2

32

3

33

4

34

5

35

6

36

7

37

8

38

9

39

10

40

11

41

12

42

13

43

14

44

15

45

16

46

17

47

18

48

19

49

20

50

21

51

22

52

23

53

24

54

25

55

26

56

27

57

28

58

29

59

30

60

30 60

311

1

2

3

4

7

8

9

10

6B

5A

Dia

gS

tat

G48T a 41515

2 51 2 62 2 73 2 84 2 95 3 06 3 17 3 28 2 39 3 41 0 3 51 1 3 61 2 3 71 3 3 81 4 3 91 5 4 01 6 4 11 7 4 21 8 4 31 9 4 42 0 4 52 1 4 62 2 4 72 3 4 82 4

ab

Dia

gS

tat

G48T a 41515

2 51 2 62 2 73 2 84 2 95 3 06 3 17 3 28 2 39 3 41 0 3 51 1 3 61 2 3 71 3 3 81 4 3 91 5 4 01 6 4 11 7 4 21 8 4 31 9 4 42 0 4 52 1 4 62 2 4 72 3 4 82 4

ab

Dia

gS

tat

G48T a 41515

2 51 2 62 2 73 2 84 2 95 3 06 3 17 3 28 2 39 3 41 0 3 51 1 3 61 2 3 71 3 3 81 4 3 91 5 4 01 6 4 11 7 4 21 8 4 31 9 4 42 0 4 52 1 4 62 2 4 72 3 4 82 4

ab

Dia

gS

tat

G48T a 41515

2 51 2 62 2 73 2 84 2 95 3 06 3 17 3 28 2 39 3 41 0 3 51 1 3 61 2 3 71 3 3 81 4 3 91 5 4 01 6 4 11 7 4 21 8 4 31 9 4 42 0 4 52 1 4 62 2 4 72 3 4 82 4

ab MSM-G8X 41211

ERR

ENV

1000BASE-X

1

5 8

4

MSTR/DIAG

SYS/STATCOMPACT FLASH

ACONSOLE

D RMGMT

4 83 72 61 5

MSM-G8X 41211

ERR

ENV

1000BASE-X

1

5 8

4

MSTR/DIAG

SYS/STATCOMPACT FLASH

ACONSOLE

D RMGMT

4 83 72 61 5

Dia

gS

tat

G48T a 41515

2 51 2 62 2 73 2 84 2 95 3 06 3 17 3 28 2 39 3 41 0 3 51 1 3 61 2 3 71 3 3 81 4 3 91 5 4 01 6 4 11 7 4 21 8 4 31 9 4 42 0 4 52 1 4 62 2 4 72 3 4 82 4

ab

Dia

gS

tat

10GBASE-X1 32 4

10G4X 41611

Dia

gS

tat

10GBASE-X1 32 4

10G4X 41611

1 2 3 4 A B 5 6 7 8

CONSOLE

MGMT

COMPACTFLASH

MSM-1XL60016

MS

TR

EN

V

SY

S

ER

R

CONSOLE

MGMT

COMPACTFLASH

MSM-1XL60016

MS

TR

EN

V

SY

S

ER

R

10G6X61050

DS

1

2

3

4

5

6

1

2

3

4

5

6

G60X61010

1

31

2

32

3

33

4

34

5

35

6

36

7

37

8

38

9

39

10

40

11

41

12

42

13

43

14

44

15

45

16

46

17

47

18

48

19

49

20

50

21

51

22

52

23

53

24

54

25

55

26

56

27

57

28

58

29

59

30

60

30 60

311

DS

G60X61010

1

31

2

32

3

33

4

34

5

35

6

36

7

37

8

38

9

39

10

40

11

41

12

42

13

43

14

44

15

45

16

46

17

47

18

48

19

49

20

50

21

51

22

52

23

53

24

54

25

55

26

56

27

57

28

58

29

59

30

60

30 60

311

DS

G60T61030

DS

1

31

2

32

3

33

4

34

5

35

6

36

7

37

8

38

9

39

10

40

11

41

12

42

13

43

14

44

15

45

16

46

17

47

18

48

19

49

20

50

21

51

22

52

23

53

24

54

25

55

26

56

27

57

28

58

29

59

30

60

30 60

311

G60T61030

DS

1

31

2

32

3

33

4

34

5

35

6

36

7

37

8

38

9

39

10

40

11

41

12

42

13

43

14

44

15

45

16

46

17

47

18

48

19

49

20

50

21

51

22

52

23

53

24

54

25

55

26

56

27

57

28

58

29

59

30

60

30 60

311

1

2

3

4

7

8

9

10

6B

5A

Dia

gS

tat

G48T a 41515

2 51 2 62 2 73 2 84 2 95 3 06 3 17 3 28 2 39 3 41 0 3 51 1 3 61 2 3 71 3 3 81 4 3 91 5 4 01 6 4 11 7 4 21 8 4 31 9 4 42 0 4 52 1 4 62 2 4 72 3 4 82 4

ab

Dia

gS

tat

G48T a 41515

2 51 2 62 2 73 2 84 2 95 3 06 3 17 3 28 2 39 3 41 0 3 51 1 3 61 2 3 71 3 3 81 4 3 91 5 4 01 6 4 11 7 4 21 8 4 31 9 4 42 0 4 52 1 4 62 2 4 72 3 4 82 4

ab

Dia

gS

tat

G48T a 41515

2 51 2 62 2 73 2 84 2 95 3 06 3 17 3 28 2 39 3 41 0 3 51 1 3 61 2 3 71 3 3 81 4 3 91 5 4 01 6 4 11 7 4 21 8 4 31 9 4 42 0 4 52 1 4 62 2 4 72 3 4 82 4

ab

Dia

gS

tat

G48T a 41515

2 51 2 62 2 73 2 84 2 95 3 06 3 17 3 28 2 39 3 41 0 3 51 1 3 61 2 3 71 3 3 81 4 3 91 5 4 01 6 4 11 7 4 21 8 4 31 9 4 42 0 4 52 1 4 62 2 4 72 3 4 82 4

ab MSM-G8X 41211

ERR

ENV

1000BASE-X

1

5 8

4

MSTR/DIAG

SYS/STATCOMPACT FLASH

ACONSOLE

D RMGMT

4 83 72 61 5

MSM-G8X 41211

ERR

ENV

1000BASE-X

1

5 8

4

MSTR/DIAG

SYS/STATCOMPACT FLASH

ACONSOLE

D RMGMT

4 83 72 61 5

Dia

gS

tat

G48T a 41515

2 51 2 62 2 73 2 84 2 95 3 06 3 17 3 28 2 39 3 41 0 3 51 1 3 61 2 3 71 3 3 81 4 3 91 5 4 01 6 4 11 7 4 21 8 4 31 9 4 42 0 4 52 1 4 62 2 4 72 3 4 82 4

ab

Dia

gS

tat

10GBASE-X1 32 4

10G4X 41611

Dia

gS

tat

10GBASE-X1 32 4

10G4X 41611

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48

CONSOLE

49 50

MGM

T

PORT 49

PORT 50

Extreme Networks Summit48siR

3804lpine

1

2

3

4

DIAG

STATUS

A

B

PSU CONSOLE MODEM MGMT

PCMCIALINK\ACTIVE

SMM45014

i

GM-4X45112

i

STATUS

1000 BASE-X

4321

GREEN

AMBER

FLASHING ORANGE

- ACTIVITY

- LINK OK

- DISABLED1 2 3 4

GM-4X45112

i

STATUS

1000 BASE-X

4321

GREEN

AMBER

FLASHING ORANGE

- ACTIVITY

- LINK OK

- DISABLED1 2 3 4

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48

CONSOLE

49 50

MGM

T

PORT 49

PORT 50

Extreme Networks Summit48siR

3804lpine

1

2

3

4

DIAG

STATUS

A

B

PSU CONSOLE MODEM MGMT

PCMCIALINK\ACTIVE

SMM45014

i

GM-4X45112

i

STATUS

1000 BASE-X

4321

GREEN

AMBER

FLASHING ORANGE

- ACTIVITY

- LINK OK

- DISABLED1 2 3 4

GM-4X45112

i

STATUS

1000 BASE-X

4321

GREEN

AMBER

FLASHING ORANGE

- ACTIVITY

- LINK OK

- DISABLED1 2 3 4

CONSOLE

FAN

PSU-i

PSU-E

Stack

MGMT

SolidBlinking Extreme Networks Summit 400-48t

R R

1 5

2 6

3 7

4 8

1x 2x 3x 4x 5 76 8 9 11 13 1510 12 14 161 32 4 25 27 29 3126 28 30 3217 19 21 2318 20 22 24 41 43 45 4742 44 46 4833 35 37 3934 36 38 40

Extreme NetworksSummit EPS-T

CONSOLE

FAN

PSU-i

PSU-E

Stack

MGMT

SolidBlinking Extreme Networks Summit 400-48t

R R

1 5

2 6

3 7

4 8

1x 2x 3x 4x 5 76 8 9 11 13 1510 12 14 161 32 4 25 27 29 3126 28 30 3217 19 21 2318 20 22 24 41 43 45 4742 44 46 4833 35 37 3934 36 38 40

Extreme NetworksSummit EPS-T

FWE-WK FWE-EG

DMZ-WK

SLB-WK SRV-WK SRV-EG

SRV-SEC-WK SRV-SEC-EG

SLB-WK

DMZ-EG

Page 9: © University of Reading 2006. uk 20 April 2014 Network Infrastructure IT Supporters Update – 26 June 2007

9To put your footer here go to View > Header and Footer

Server connectivity upgrade

Page 10: © University of Reading 2006. uk 20 April 2014 Network Infrastructure IT Supporters Update – 26 June 2007

10To put your footer here go to View > Header and Footer

Guest / wireless network changes

• Deployment of JANET Roaming / Eduroam– Web-based redirect no longer permitted to be

advertised as eduroam name– New wireless network across campus to sit alongside

existing service• SSID ‘eduroam’• Requires 802.1x and WPA / WPA2 encryption• Set up and forget – works everywhere that has

Eduroam

Page 11: © University of Reading 2006. uk 20 April 2014 Network Infrastructure IT Supporters Update – 26 June 2007

11To put your footer here go to View > Header and Footer

Guest / wireless network changes

• Changes to existing ‘rdg.ac.uk’ service– Will move outside firewall

• But retain protection from Internet hosts• Same set of base services as for JANET Roaming• Additional resilience through second BlueSocket device

– Web-based login will accept eduroam / JANET Roaming credentials

– Proposed service changes Summer 2008:• Users will no longer be able to sign on with plain

username– Must use ‘[email protected]’ instead

• Native CIFS access will be turned off – shares still accessible through NetDrive service (WebDAV gateway)

Page 12: © University of Reading 2006. uk 20 April 2014 Network Infrastructure IT Supporters Update – 26 June 2007

12To put your footer here go to View > Header and Footer

Guest / wireless network changes

• New IP address ranges:– 134.225.24.0 – 134.225.27.255 for JANET Roaming

service– 134.225.28.0 – 134.225.31.255 for plug-in and

‘rdg.ac.uk’ service

• Old address ranges to be removed by September 2007:– 134.225.8.0 – 134.225.15.255

Page 13: © University of Reading 2006. uk 20 April 2014 Network Infrastructure IT Supporters Update – 26 June 2007

13To put your footer here go to View > Header and Footer

Subnet changes

• Psychology to complete move to .114 subnet

• Soil and Plant Science to move to own subnets

• Systems Engineering to vacate .4 and .56 subnets

• Student subnets in Careers, Chaplaincy and RUSU to be separated

Page 14: © University of Reading 2006. uk 20 April 2014 Network Infrastructure IT Supporters Update – 26 June 2007

14To put your footer here go to View > Header and Footer

DNS / DHCP infrastructure

• Currently two central servers– Sun hardware– Open source software– A bunch of in-house scripts to generate DNS zones– More in-house scripts to generate DHCP configuration– Painful to manage– Relatively slow turn-around for IP address allocation

Page 15: © University of Reading 2006. uk 20 April 2014 Network Infrastructure IT Supporters Update – 26 June 2007

15To put your footer here go to View > Header and Footer

DNS / DHCP infrastructure

• New Infoblox 1550 appliances (HA pair)– Take over as master DNS database– Replace Sun boxes for DHCP– GUI for managing IP address and hostname allocation– Should give faster turn-around on IP allocations– Possibility of delegation (at least read-only) to IT

supporters

• Expansion of DNS topology– Existing Sun boxes become dedicated DNS cache servers– Addition of DNS servers into DMZ for best practise– Possible additional IT Services managed DNS secondary

server at off-site co-location facility