· pd-1 planter drain --- --- 3" --- zurn z350-g dome type planting area drain, dura-coated...
TRANSCRIPT
Attachments: Partial sheets:
Reissued full sheets: NNTT PPGG 77000022
By: Chad Blanchard
DESIGNER SUPPLEMENTAL INSTRUCTIONS DSI NO. MCA-DSI-0016
DDAATTEE:: 0099//1155//22001166
PPRROOJJEECCTT NNAAMMEE:: NNOOAABB PPrroojjeecctt ## 88991100--0011223333
LLoouuiiss AArrmmssttrroonngg NNeeww OOrrlleeaannss IInntteerrnnaattiioonnaall AAiirrppoorrtt NNoorrtthh TTeerrmmiinnaall DDeevveellooppmmeenntt PPrrooggrraamm PPhhaassee 11
Note: if the following information is deemed to have an impact on GMP Price or time, submit a proposal for Owner approval before proceeding with this DSI. If approved by Owner, the resulting contract change will be incorporated in the next formal Change Order.
RReevviisseedd ddrraawwiinngg NNTT PPGG 77000022,, ttoo bbee iissssuueedd iinn ccoonnjjuunnccttiioonn wwiitthh rreessppoonnssee ttoo RRFFII 0000888855.. CCoosstt iimmppaacctt:: NNoonnee
From: Dean Schuerman To: Cedric Johnson CC: Daniel Taylor, David Daileda, Jason Levy, David Zelig, Sara Delahoussaye, Raymond Symanski, Brian Miller, Carlos Giron,
Chad Blanchard, Greg DeCoursey, Dong Liu
RFI 00885 From Cedric Johnson
To Dean Schuerman
CC Cinda Denoux, Daniel Taylor, Gordon Jones, Kiet Vo, Sara Delahoussaye, Cedric Johnson, Cindy Shields, David Daileda, Jason Levy, Raymond Symanski, Scott Rydin
Project North Terminal Project - NOLA (MSY) Construction Subject 3.2.1/3.3.1_NT AT 5041/NT PG 7002_Terminal_Plumbing Toilet Fixture Height
Subject: 3.2.1/3.3.1_NT AT 5041/NT PG 7002_Terminal_Plumbing Toilet Fixture Height Date Required: 2016-09-15 Cost Impact: Potentially Cost Amount:
Question: Plumbing drawing NT PG 7002 schedule indicates fixture WC-1 height of 14" and fixture WC-2 (ADA) height of 17". Drawing NT AT 5041 restroom elevation view indicated a dimension of 16" for the ADA toilet and 15" for the standard toilet. (see attached drawings). Typical installation of a non ADA toilet is 15" to the rim and 17" to the rim for an ADA toilet. Please confirm height of the toilets from finished floor.
Suggestion:
Answer:
NOTE: An RFI response cannot change the requirements of the Contract Documents. Response By: Raymond Symanski Date: 09/09/2016 CCAT Response: Provide at non ADA toilet 15" to the Seat rim and 17" to the Seat rim for an ADA toilet. (See
guidelines in Vol. 1, Sheet GN AG 0081 , Detail 8 ) Cost Impact: none Pursuant to paragraph 4.2.14 of the General Conditions of the Contract, the Engineer of Record provides the following response to the referenced RFI. This RFI response does not constitute a Construction Change Directive, and does not authorize changes in project scope, contract price or time. Refer also to Article 7 of the General Conditions and for AIP work to Article 50-16 of the FAA General Provisions. RFI’s are to be returned for reconsideration if there is a cost or schedule impact.
R E Q U E S T F O R I N T E R P R E T A T I O N
PLUMBING FIXTURE SCHEDULE
WC-2
L-1
L-2
DF-1
MB-1
UR-1
UR-2
HB-1
WH-1
SH-1
SD-1
FD-1
WATER CLOSET (ADA)
LAVATORY
LAVATORY (ADA)
DRINKING FOUNTAIN
MOP BASIN
URINAL
URINAL (ADA)
HOSE BIBB
WALL HYDRANT
SHOWER FAUCET
SHOWER DRAIN
FLOOR DRAIN
1"
---
3/4"
3/4"
3/4"
3/4"
1/2"
---
---
1/2"
---
---
---
---
1/2"
---
3"
2"
2"
2"
---
---
---
3"
2"
2"
2"
2"
---
---
---
2"
--- 1/2" 2" 2"
1/2" --- 2" 2"
3/4" 3/4" 3" 2"
--- --- 3" 2"
KOHLER
KOHLER
HALSEY TAYLOR
FIAT
KOHLER
KOHLER
WOODFORD
ZURN
ZURN
K-5400
K-5400
OVL-II BI-LEVEL
MSB-2424
K-4991-ER
24C
Z1300
Z415B-P-VP
KOHLER K-4323
K-4991-ER
BOTH FOUNTAINS SHALL INCLUDE PUSHBAR ON THE BOTH SHALL INCLUDECONTOUR-FORMED BASINS TO ELIMINATE SPLASHING AND STANDING WATER, AND
SHALL HAVE ROUNDED CORNERS AND EDGES. EACH PROJECTOR SHALL BETWO-STREAM, MOUND-BUILDING TYPE WITH INTEGRAL HOOD GUARD AND ANTI-SQUIRT
FEATURE. FOUNTAIN SHALL COMPLY WITH ANSI 117:1 AND ADA FOR VISUAL AND MOTIONDISABILITIES. THE MANUFACTURER SHALL CERTIFY THE UNIT TO MEET THE
REQUIREMENTS OF ANSI/NSF 61, AND THE SAFE DRINKING WATER ACT.
ZURN, FLORESTONE, ACORNENG. OR APPROVED EQUAL
J.R. SMITH, WADE, ZURN, ORAPPROVED EQUAL
J.R. SMITH, WADE, WATTS,OR APPROVED EQUAL
MARK
WC-1
TYPE
WATER CLOSET
MANUFACTURER MODELDCW
1"
DHW
---
WASTE
3"
VENT
2"VITREOUS CHINA, ONE PIECE, WALL HUNG, FLUSH VALVE, 15" HIGH
ELONGATED BOWL DIRECT-FED SIPHON JET ACTION, 1-1/2" INLET BACK SPUD,2" BALLPASS TRAPWAY 1.6 GAL PER FLUSH
DESCRIPTION
KOHLER K-4323
BASIS OF DESIGN
ELJER, AMERICAN STANDARD,TOTO, OR APPROVED EQUAL
OTHER ACCEPTABLEMANUFACTURERS
SLOAN 152-1.6 ES-S TMO SWBWITH EL-154 TRANSFORMER
ELJER, AMERICAN STANDARD,TOTO, OR APPROVED EQUAL
FAUCETS/FLUSH VALVES
VITREOUS CHINA, ONE PIECE, WALL HUNG, FLUSH VALVE, 17" HIGH ELONGATEDBOWL DIRECT-FED SIPHON JET ACTION, 1-1/2" INLET BACK SPUD, 2" BALLPASS
TRAPWAY 1.6 GAL PER FLUSH, OPEN FRONT PLASTIC SEAT
TRIM ACCESSORIES
MOLDED STONE IN MATCHED METAL DIES UNDER HEAT AND PRESSURE ONEPIECE BASIN, 24 X 24 X 10 DEEP, 3-1/2" DRAIN OPENING STAINLESS STEEL FLAT
GRID STRAINERFIAT 830-AA
ELJER, AMERICAN STANDARD,TOTO, OR APPROVED EQUAL
ELJER, AMERICAN STANDARD,TOTO, OR APPROVED EQUAL
VITREOUS CHINA WALL HUNG, REAR OUTLET, REAR SPUD, FLUSHING RIM, LOWCONSUMPTION, WASHOUT FLUSH ACTION EXTENDED PRIVACY SHIELDS, 2 INCH OUTLET
CONNECTION, WALL HANGERS, MEETS ANSI FLUSH REQUIREMENTSVITREOUS CHINA WALL HUNG, REAR OUTLET, REAR SPUD, FLUSHING RIM, LOW
CONSUMPTION, WASHOUT FLUSH ACTION EXTENDED PRIVACY SHIELDS, 2 INCH OUTLETCONNECTION, WALL HANGERS, MEETS ANSI FLUSH REQUIREMENTS, ADA COMPLIANT
J.R. SMITH, WOODFORD, WATTS,OR APPROVED EQUAL
FCO FLOOR CLEAN OUT --- --- 3" 2" ZURN Z1400-VP
DURA-COATED CAST IRON BODY WITH BOTTOM OUTLET, COMBINATION INVERTIBLEMEMBRANE CLAMP AND ADJUSTABLE COLLAR, TYPE 'B' STRAINER TRAP PRIMER
CONNECTION, 1 - 3" EXTENSION ADAPTER, VANDAL PROOF SCREWSADJUSTABLE POLISHED BRONZE FLOOR CLEANOUT, DURA-COATED CAST IRON BODY
WITH GAS AND WATER TIGHT ADS TAPERED THREAD PLUG, ROUND SECURED TOP,VANDAL PROOF SCREWS, NO HUB CONNECTION
J.R. SMITH, WADE, WATTS,OR APPROVED EQUAL
PD-1 PLANTER DRAIN --- --- 3" --- ZURN Z350-GDOME TYPE PLANTING AREA DRAIN, DURA-COATED CAST IRON BODY WITH BOTTOM
OUTLET COMPLETE WITH COMBINATION MEMBRANE FLASHING CLAMP/GRAVELGUARD, LOW SILHOUETTE DOME AND STAINLESS STEEL MESH SCREEN OVER DOME.
J.R. SMITH, WADE, WATTS,OR APPROVED EQUAL
ENCASED ECOLOTROL "ANTI-SIPHON" AUTOMATIC DRAINING WALL HYDRANT FOR FLUSHINSTALLATION. COMPLETE WITH NON-FREEZE TYPE INTEGRAL BACKFLOW PREVENTER,BRONZE CASING, ALL BRONZE INTERIOR PARTS, NON-TURNING OPERATING ROD WITH
FREE-FLOATING COMPRESSION CLOSURE VALVE, REPLACEABLE BRONZE SEAT AND SEATWASHER. NICKEL BRONZE BOX AND HINGED COVER WITH OPERATING KEY LOCK AND
"WATER" CAST ON COVER.
SLOAN ETF-600-B FOR SINGLE LAVATORYSLOAN ETF-600/EL-208 FOR BANK OF 6 OR LESS
SLOAN ETF-600-B FOR SINGLE LAVATORYSLOAN ETF-600/EL-208 FOR BANK OF 6 OR LESS
ENAMELED CAST IRON, UNDER MOUNT TYPEELJER, AMERICAN STANDARD,TOTO, OR APPROVED EQUAL
ELJER, AMERICAN STANDARD,TOTO, OR APPROVED EQUAL ENAMELED CAST IRON, UNDER MOUNT TYPE
ELKAY, OASIS, BRADLEY, ORAPPROVED EQUAL
ANTI-SIPHON VACUUM BREAKER BRASS EXTERIOR FINISH, WHEELE HANDLE WITHOPTIONAL LOOSE KEY TEE, BRASS CONSTRUCTION WITH ADJUSTABLE PACKING NUT,
TEFLON IMPREGNATED PACKING AND STANDARD 'O' RING
TRUEBRO GUARD 2 WITH OFFSETTRAP
McGUIRE 165
McGUIRE 165
SLOAN 152-1.6 ES-S TMO SWBWITH EL-154 TRANSFORMER
SLOAN 195-1.5 ES-S
SLOAN 195-1.5 ES-S
BRILL SYSTEM TOILET SEATOR APPROVED EQUAL
BRILL SYSTEM TOILET SEATOR APPROVED EQUAL
WC-3 1" --- 3" 2" ACORN ENGINEERING 1675-W-1WATER CLOSET(SECURITY ADA)
PROVIDE AND INSTALL ACORN PENAL-WARE BLOWOUT JET TOILET (SPECIFY MODELNUMBER AND OPTIONS). TOILET BOWL SHALL BE FABRICATED FROM 14 GAGE, TYPE 304
STAINLESS STEEL. CONSTRUCTION SHALL BE SEAMLESS WELDED AND EXPOSEDSURFACES SHALL HAVE A SATIN FINISH. TOILET SHALL BE CONCEALED BLOWOUT JETTYPE WITH AN ELONGATED BOWL, A SELF-DRAINING FLUSHING RIM, AND AN INTEGRAL
CONTOURED SEAT. TOILET SHALL MEET ASME A112.19.3-2008 AND CSA B45.4-2008REQUIREMENTS AND WILL FLUSH WITH A MINIMUM OF 25 PSI FLOW PRESSURE WHEN
USED IN CONJUNCTION WITH A MINIMUM OF 1.6 GPF. TOILET TRAP SHALL HAVE AMINIMUM 3-1/2" SEAL THAT SHALL PASS A 2-1/8" DIAMETER BALL AND BE FULLYENCLOSED. FIXTURE SHALL WITHSTAND LOADINGS OF 3,000 POUNDS WITHOUT
PERMANENT DAMAGE. FIXTURE SHALL BE FURNISHED WITH NECESSARY FASTENERSFOR PROPER INSTALLATION.
BRADLEY, WILLOUGHBY,KINDRED, OR APPROVED EQUAL
L-3 --- 1/2" 2" 2" AMERICAN STANDARD SLOAN ETF-600-B FOR SINGLE LAVATORYSLOAN ETF-600/EL-208 FOR BANK OF 6 OR LESS
ELJER, AMERICAN STANDARD,TOTO, OR APPROVED EQUAL McGUIRE 165LAVATORY (ADA) TRUEBRO GUARD 2 WITH OFFSET
TRAP
RD-1 ROOF DRAIN --- --- SEE PLANS --- ZURN J.R. SMITH, WADE, WATTS,OR APPROVED EQUAL
VITREOUS CHINA, COUNTER TOP, 20 X 18 OVAL BOWL, SELF RIMMING, FRONTOVERFLOW, FAUCET LEDGE, TEMPLATE WITH COLOR MATCHING SEALANTAQUALY 476.028
WCO WALL CLEANOUT --- --- SEE PLANS --- ZURN J.R. SMITH, WADE, WATTS,OR APPROVED EQUALZ1446
Z187
CLEANOUT TEE, DURA-COATED CAST IRON BODY, GAS ANDWATERTIGHT ABS TAPERED THREAD PLUG, AND ROUND, SMOOTHSTAINLESS STEEL WALL ACCESS COVER WITH SECURING SCREW.
MB-2 MOP BASIN 3/4" 3/4" 3" 2" FIAT MSB-3636 ZURN, FLORESTONE, ACORNENG. OR APPROVED EQUAL
MOLDED STONE IN MATCHED METAL DIES UNDER HEAT AND PRESSURE ONEPIECE BASIN, 36 X 36 X 10 DEEP, 3-1/2" DRAIN OPENING STAINLESS STEEL FLAT
GRID STRAINERFIAT 830-AA
PH-1 POST HYDRANT 1" --- --- --- JAY R. SMITH 5906LF ZURN, WADE, WATTS, ORAPPROVED EQUAL
ZURN FD2251 J.R. SMITH, WADE, WATTS,OR APPROVED EQUAL
COMPLETE WITH A PVC OR ABS BODY, CAST IRON DRAIN HEAD, ANDSTAINLESS STEEL FRAME AND SECURED SLOTTED STRAINER. SOLVENT
WELD OUTLET CONNECTION FITS OVER 2".
J.R. SMITH, WADE, WATTS,OR APPROVED EQUALSYMMONS TEMPTROL 2000 25-1
PRESSURE BALANCING MIXING VALVE WITH ADJUSTABLE STOP SCREWTO LIMIT HANDLE TURN, CLEAR-FLO SHOWER HEAD WITH ARM AND
FLANGE.
SLOAN PRISON MODEL FLUSHOMETER 611-1.6
S-1 SINK 1/2" 1/2" 2" 2" ELKAY LR2219PD ELJER, AMERICAN STANDARD,TOTO, OR APPROVED EQUAL
18 GAUGE STAINLESS STEEL SINGLE COMPARTMENT COUNTER TOP SINK, SELF-RIMMING,HAND BLENDED SATIN FINISH, 3-1/.2" DRAIN OPENING, 3 HOLE PUNCH, 8" O.C. HEAVY DUY
SOUND COATED UNDERSIDE
NON-FREEZE ROOF HYDRANT WITH GALVANIZED CASING ANDADJUSTABLE FLOW WHEEL LOCK HANDLE WITH DECK FLANGE AND
UNDER DECK CLAMP.
ZURN Z-831A1
8 X 12 SCUPPER DRAIN, DURA-COATED CAST IRON BODY WITH REVERSIBLEBACK OR BOTTOM OUTLET, OBLIQUE ALUMINUM GRATE WITH 90°
COMBINATION FRAME AND MEMBRANE FLASHING CLAMP.
WF-1 WALL FAUCET 3/4" 3/4" --- --- FIAT FIAT 830-AAFIAT 830-AA J.R. SMITH, WADE, WATTS,OR APPROVED EQUAL
CHROME PLATED WITH VACUUM BREAKER, INTEGRAL STOPS, ADJUSTABLE WALLBRACE, PAIL HOOK AND 3/4” HOSE THREAD ON SPOUT. BODY INLETS 8” CENTER TO
CENTER, FOUR ARM HANDLES. VALVES CONTAIN RENEWABLE HUB, RENEWABLE SEATS,SWIVEL DISCS, ENCASED WASHERS AND BRASS WASHER SCREWS.
ZURN Z895 J.R. SMITH, WADE, WATTS,OR APPROVED EQUALTD-1 --- --- 4" ---
TRENCH DRAIN(WITH TRAFFIC GRADE
GRATE)
CHANNELS SHALL BE 60" LONG, 12" WIDE AND HAVE A 9-1/8" THROAT. MODULAR CHANNELSECTIONS SHALL BE MADE OF 12GA. FABRICATED STAINLESS STEEL CONFORMING TO
ASTM A-240 (TYPE 304). CHANNELS SHALL HAVE A BOLTED, FLANGED CONNECTIONBETWEEN CHANNEL SECTIONS THAT WILL NOT SEPARATE DURING THE INSTALLATION,GASKETS AVAILABLE. CHANNELS SHALL WEIGH LESS THAN 4.15 LBS. PER LINEAR FOOT,
HAVE A SMOOTH, 1-1/2" RADIUSED SELF CLEANING BOTTOM WITH A MANNING’SCOEFFICIENT OF .009 AND 1.04% OR NEUTRAL 0% BUILT IN SLOPE. CHANNELS SHALL
HAVE FEET FOR PATTY POUR OR LEVELING STUDS STANDARD TO SECURE TRENCH INITS FINAL LOCATION 10-0" LONG.
16 GALLON "AQUAGUARD" GRAVITY-FLOW PORTABLE EYE WASH UNIT WITH HEAVY DUTYPOLYETHYLENE TANK, WALL OR COUNTER MOUNTED. PROVIDE WALL BRACKET.
SUPPLIED WITH 3' DRAIN HOSE, EPOXY COATED STEEL BRACKET. DELIVERS 0.7 GPMFOR 15 MINUTES. UNIT SHALL INCLUDE ANSI COMPLIANT SIGN. UNIT SHALL BE FULLYASSEMBLED AND TESTED TO MEET OR EXCEED ANSI Z358.1 - 2009, AND COME WITH A
FULL 2-YEAR WARRANTY.
GUARDIAN G1540 GUARDIAN ORAPPROVED EQUALEEW-1 --- --- --- ---SELF CONTAINED
EMERGENCY EYE WASH
2'
SCALE : 3/8" = 1'-0"
0 4' 6'
KEY PLAN
REVISIONS
FILE LOG
ACTIVITY
Draw
Design
Manager
Check
STAMP
© LEO A DALY Company 2015
PROJECT NO.
BY
THE NEW ORLEANSAVIATION BOARD
CRESCENT CITYAVIATION TEAM
1 GALLERIA BOULEVARD #1516METAIRIE, LA 70001T (504) 303.7535 / F (504) 841.2229
A JOINT VENTURE
NORTH TERMINALLOUIS ARMSTRONGNEW ORLEANSINTERNATIONALAIRPORTPROJECT ADDRESSKENNER, LOUSIANA ZIP
THE NEW ORLEANS AVIATIONBOARD, 900 EAST AIRLINEDRIVE, KENNER, LA 70062
Signature: Date:
NO. DESCRIPTION DATE
CONFORMED SET 02-08-2016
9/15
/201
6 3:
04: 2
7 PM
Owner
PLUMBING SCHEDULES
NT PG 7002
051-10250-00002-08-2016
GRC
JLC
JLC
ISSUED FOR CONSTRUCTION
VOLUME 3.3.1
M Addendum 12 01-14-2016
D Addendum 4 07-30-2015
C Addendum 3 07-24-2015
DSI-0012 MCA-DSI-0012 08-31-2016
DSI-0014 MCA-DSI-0014 08-31-2016
DSI-0016
DSI-0016 MCA-DSI-0016 09-15-2016