INTRODUCING CARDIOSAVE™ RescueTHIS IS BIG. EVEN THOUGH IT’S REALLY SMALL.
SPECIFICATIONS
INTRODUCING A WHOLE NEW PARADIGM IN HEMODYNAMIC SUPPORT
CARDIOSAVE represents a giant leap forward in functionality and versatility while continuing
to deliver the performance and intuitiveness of the Datascope pumps you know and trust.
With its large touchscreen display, dramatically smaller and lighter design, and seamless
transition from in-hospital use to transport mode, this revolutionary pump redefines
counterpulsation therapy.
CARDIOSAVE… setting a new standard in hemodynamic support.
CARDIOSAVE RESCUE: SUMMARY TECHNICAL SPECIFICATIONS
Weight Including console, removable monitor and 2 batteries24.1 kg 53 lbsAll weights ± 5%
DimensionsDisplay Closed - Includes console and removable monitor57.2 cm high x 40.6 cm deep x 33.0 cm wide22.5 in high x 16 in deep x 13 in wide
Display Open 90°- Includes console and removable monitor78.0 cm high x 40.6 cm deep x 33.0 cm wide30.7 in high x 16 in deep x 13 in wide* All dimensions ± 5%. Dimensions include the Pneumatic Module
Operating AmbientOperating Temperature10°C to 40°C 50°F to 104°F
Operating Humidity15% to 85% Relative Humidity (non-condensing)
Operating Altitude-381.0 m to 3657.6 m 1060 hPa to 644 hPa-1250 ft to 12,000 ft 795 mmHg to 483 mmHg
Verified at discrete temperature and humidity combinations per “ECRI -PB- 296 892” guidelines.
Sinusoidal Vibration:EN 60068-2-6:2008 - Environmental Testing, Part 2 Test Fc: Vibration (sinusoidal) EN13718-1:2008 (E) section 4.6.2 which cites ISO 7137:1995. Test method is defined per RTCA/DO-160F par 8.5.1 Cat S, fuselage zone M.
Random Vibration:FDA “Reviewer Guidance for Pre-Market Notification Submissions” section n.4 (iii) specified random vibration test per IEC 68-2-34, frequency range 20 to 500 Hz, ASD 0.02g^2/Hz, duration 9 min. Nonoperational.
NOTE: IEC 68-2-34 has been superseded by IEC 60068-2-64:2008.
For ground applications:EN 1789:2007 “Medical vehicles and their equipment - Road ambulances”.
For aircraft transport: RTCA/DO-160F “Environmental Conditions and Test Procedures for Airborne Equipment”.
Bump Test: EN 1789:2007 - Medical Vehicles and their equipment - Road ambulances: Functional shock test per IEC 60068-2-29, Test Eb, 15g, duration 6 ms, 1000 times in normal operating position.Rough Handling Test: Rough Handling Test - IEC 60601-1 (1988), sub-clause 21.6, with Amendment 1 (1991) and Amendment 2 (1995)
Shock - Operational: RTCA/DO-160F Shock, Category B Operational standard test for fixed wing and helicopter: 6g, duration 11ms, saw-tooth, 3 times in each orientation
Shock - Non-Operational: EN60068-2-27:2008, Environmental Testing, Part 2 Test Ea and guidance: Shock per Table 1: 20g, duration 11 ms, saw-tooth, one in each orientation (6 total, can use dummy load)
Crash Test: EN 1789:2007 - Medical Vehicles and their equipment. RTCA/DO-160F - Environmental Conditions and Test Procedures for Airborne Equipment: Crash safety test for fixed wing and helicopter, 20g, duration 6ms, sawtooth, one in each orientation (11 total, can use dummy load) Test also satisfies EN 1789:2007 - Medical Vehicles and their equipment, section 6.3.5.
Elevator Threshold Test: ECRI PB-296892*, Section AIII.3.1
Barrier Impact Test:
ECRI PB-296892*, Section AIII.3.2.2
Drop Test: ECRI* AIII.3.3 for Class 2 Device (Test 1 - steel ball drop / device on floor)
Tip-over Test: IEC 60601-1, 1988 (plus Amendment 1:1991, Amendment 2: 1995, and
Corrigendum, June 1995) Section 4, Clause 24, Page 119
* U.S. Department of Commerce, National Technical Information Service, PB-296 892 “Development of Environmental Test Methods for Non-Implantable Devices” by Emergency Care Research Institute (ECRI), Prepared for Food and Drug Administration, Apr.1979.
Agency Compliance:
EN60601-1:1990 +A1:1993, + A2:1995 = 2nd edition EN60601-1-2:2007EN60601-1-8:2007EN60601-2-34:2000
1, 2
UL 60601-1:2003CSA C22.2 - No. 601.1 - M90CSA C22.2 - No. 601.1S1 - 94EC Medical Device Directive 93/42/EECWEEE Compliance: this system is in compliance with European Community Directive, 2002/96/EC with regard to waste management.
1 When tested with Baxter, Model PX 600 or Abbott®, Model 42582-05 disposable pressure transducers.2 The technology and auto calibration feature associated with the fiber-optic sensor necessitates deviations from test requirements of sections 51.102.1 (Sensitivity, repeatability, non-linearity, drift and hysteresis) and 51.102 2 (Accuracy of systolic and diastolic pressure) of the IEC 606012-34:2000 standard. The test requirements of these two sections were fulfilled via equivalent test methodologies developed by MAQUET
Standard Accessories:
Battery charging station AC Transport Power Supply
Helium refilling station Transport mounting plate
Removable monitor
Swivel monitor mount
Handle lifting points
Handle lifting point
Ethernet port
Printer
USB connector
ECG input
Pressure input
Low level BP output - to bedside monitor
ECG monitor input
Low level BP output - vent button
Pressure monitor input
Ambient temperature sensor
Trainer input
Equipotential lug
Battery charge indication lights
IABP power button
IAB catheter extender input
IAB sensor input
Retractable wheels
2 hot swappable lithium ion batteries
Battery bay in-use indicators
Backlit touchscreen
Backlit monitor display
Retractable handle
CARDIOSAVE RESCUE: SUMMARY TECHNICAL SPECIFICATIONS
Weight Including console, removable monitor and 2 batteries24.1 kg 53 lbsAll weights ± 5%
DimensionsDisplay Closed - Includes console and removable monitor57.2 cm high x 40.6 cm deep x 33.0 cm wide22.5 in high x 16 in deep x 13 in wide
Display Open 90°- Includes console and removable monitor78.0 cm high x 40.6 cm deep x 33.0 cm wide30.7 in high x 16 in deep x 13 in wide* All dimensions ± 5%. Dimensions include the Pneumatic Module
Operating AmbientOperating Temperature10°C to 40°C 50°F to 104°F
Operating Humidity15% to 85% Relative Humidity (non-condensing)
Operating Altitude-381.0 m to 3657.6 m 1060 hPa to 644 hPa-1250 ft to 12,000 ft 795 mmHg to 483 mmHg
Verified at discrete temperature and humidity combinations per “ECRI -PB- 296 892” guidelines.
Sinusoidal Vibration:EN 60068-2-6:2008 - Environmental Testing, Part 2 Test Fc: Vibration (sinusoidal) EN13718-1:2008 (E) section 4.6.2 which cites ISO 7137:1995. Test method is defined per RTCA/DO-160F par 8.5.1 Cat S, fuselage zone M.
Random Vibration:FDA “Reviewer Guidance for Pre-Market Notification Submissions” section n.4 (iii) specified random vibration test per IEC 68-2-34, frequency range 20 to 500 Hz, ASD 0.02g^2/Hz, duration 9 min. Nonoperational.
NOTE: IEC 68-2-34 has been superseded by IEC 60068-2-64:2008.
For ground applications:EN 1789:2007 “Medical vehicles and their equipment - Road ambulances”.
For aircraft transport: RTCA/DO-160F “Environmental Conditions and Test Procedures for Airborne Equipment”.
Bump Test: EN 1789:2007 - Medical Vehicles and their equipment - Road ambulances: Functional shock test per IEC 60068-2-29, Test Eb, 15g, duration 6 ms, 1000 times in normal operating position.Rough Handling Test: Rough Handling Test - IEC 60601-1 (1988), sub-clause 21.6, with Amendment 1 (1991) and Amendment 2 (1995)
Shock - Operational: RTCA/DO-160F Shock, Category B Operational standard test for fixed wing and helicopter: 6g, duration 11ms, saw-tooth, 3 times in each orientation
Shock - Non-Operational: EN60068-2-27:2008, Environmental Testing, Part 2 Test Ea and guidance: Shock per Table 1: 20g, duration 11 ms, saw-tooth, one in each orientation (6 total, can use dummy load)
Crash Test: EN 1789:2007 - Medical Vehicles and their equipment. RTCA/DO-160F - Environmental Conditions and Test Procedures for Airborne Equipment: Crash safety test for fixed wing and helicopter, 20g, duration 6ms, sawtooth, one in each orientation (11 total, can use dummy load) Test also satisfies EN 1789:2007 - Medical Vehicles and their equipment, section 6.3.5.
Elevator Threshold Test: ECRI PB-296892*, Section AIII.3.1
Barrier Impact Test:
ECRI PB-296892*, Section AIII.3.2.2
Drop Test: ECRI* AIII.3.3 for Class 2 Device (Test 1 - steel ball drop / device on floor)
Tip-over Test: IEC 60601-1, 1988 (plus Amendment 1:1991, Amendment 2: 1995, and
Corrigendum, June 1995) Section 4, Clause 24, Page 119
* U.S. Department of Commerce, National Technical Information Service, PB-296 892 “Development of Environmental Test Methods for Non-Implantable Devices” by Emergency Care Research Institute (ECRI), Prepared for Food and Drug Administration, Apr.1979.
Agency Compliance:
EN60601-1:1990 +A1:1993, + A2:1995 = 2nd edition EN60601-1-2:2007EN60601-1-8:2007EN60601-2-34:2000
1, 2
UL 60601-1:2003CSA C22.2 - No. 601.1 - M90CSA C22.2 - No. 601.1S1 - 94EC Medical Device Directive 93/42/EECWEEE Compliance: this system is in compliance with European Community Directive, 2002/96/EC with regard to waste management.
1 When tested with Baxter, Model PX 600 or Abbott®, Model 42582-05 disposable pressure transducers.2 The technology and auto calibration feature associated with the fiber-optic sensor necessitates deviations from test requirements of sections 51.102.1 (Sensitivity, repeatability, non-linearity, drift and hysteresis) and 51.102 2 (Accuracy of systolic and diastolic pressure) of the IEC 606012-34:2000 standard. The test requirements of these two sections were fulfilled via equivalent test methodologies developed by MAQUET
Standard Accessories:
Battery charging station AC Transport Power Supply
Helium refilling station Transport mounting plate
Datascope Corp.15 Law DriveFairfield, NJ 07004, USATel +1 973 244 6100Fax +1 973 244 6279 Visit our websitehttp://ca.maquet.com
GETINGE GROUP is a leading global provider of products and systems that contribute to quality enhancement and cost efficiency within healthcare and life sciences. We operate under the three brands of ArjoHuntleigh, GETINGE and MAQUET. ArjoHuntleigh focuses on patient mobility and wound management solutions. GETINGE provi-des solutions for infection control and prevention within healthcare and life sciences. MAQUET specializes in solutions, therapies and products for surgical interventions and intensive care.
MC
V-B
R-8
0000
204-
EN
-01
· PN
: 000
2-08
-106
5 R
0
MA
QU
ET
Trad
emar
k of
MA
QU
ET
Gm
bH
& C
o. K
G ·
CA
RD
IOS
AV
E is
a t
rad
emar
k of
Dat
asco
pe
Trad
emar
k C
orp
. 201
1 C
opyr
ight
Dat
asco
pe
Cor
p. o
r its
aff
iliat
es.
All
right
s re
serv
ed.
C
autio
n: U
.S. F
eder
al L
aw r
estr
icts
thi
s d
evic
e to
sal
e b
y or
on
the
ord
er o
f a
phy
sici
an. R
efer
to
Inst
ruct
ions
for
Use
for
cur
rent
ind
icat
ions
, war
ning
s, c
ontr
aind
icat
ions
, and
pre
caut
ions
. A
ll rig
hts
rese
rved
.
Cau
tion:
U.S
. Fed
eral
Law
res
tric
ts t
his
dev
ice
to s
ale
by
or o
n th
e or
der
of
a p
hysi
cian
. Ref
er t
o In
stru
ctio
ns f
or U
se f
or c
urre
nt in
dic
atio
ns, w
arni
ngs,
con
trai
ndic
atio
ns, a
nd p
reca
utio
ns.
All
right
s re
serv
ed.
C
autio
n: U
.S. F
eder
al L
aw r
estr
icts
thi
s d
evic
e to
sal
e b
y or
on
the
ord
er o
f a
phy
sici
an. R
efer
to
Inst
ruct
ions
for
Use
for
cur
rent
ind
icat
ions
, war
ning
s, c
ontr
aind
icat
ions
, and
pre
caut
ions
. ORDERING INFORMATION
Product Part Number
CARDIOSAVE Rescue 0998-00-0800-83
Accessories shipped with CARDIOSAVE Rescue:
CARDIOSAVE Battery Pack (qty 2) CARDIOSAVE Helium Refilling StationCARDIOSAVE Battery Recharging StationCARDIOSAVE Transport Mounting PlateCARDIOSAVE AC Transport Power SupplyHelium TanksCARDIOSAVE Accessory Kit:n CARDIOSAVE Blood Pressure Transducer Adapter Cablen CARDIOSAVE ECG Trunk Cable - 5 leadn CARDIOSAVE ESIS Lead Wires 50" – 5 Lead (Op Rm)n External Signal Cablen CARDIOSAVE Operators Manual - DVDn CARDIOSAVE Non-locking Male Luer Plug (qty 5)n Helium Cylinder Washer (qty 5)n Thermal Recorder Chart Paper Starter Packn Fiber Optic Cleaning Swabs (qty 5)n Fiber Optic Connector Cleanern CARDIOSAVE Plastic Weather Covern CARDIOSAVE Allen Wrench